• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
571

Análise comparativa do desajuste marginal de infra-estruturas de prótese fixa pilares micro-unit com o uso de retificadores manuais

Alonso, Fernando Rizzo January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:13Z (GMT). No. of bitstreams: 2 000399361-0.pdf: 8314993 bytes, checksum: a3c46db6ec5de11b04392bd9c5ca0dce (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The percentage of new bone formation was greater in the LLLT group (57. 89%) than in the control group (46. 75%) (p=0. 006). The analysis of chemical composition and of Ca and P ratios showed greater mineralization in the LLLT group. Crystallinity percentages were greater in rabbits in the LLLT group. Diffractograms showed that crystalline structures were similar to hydroxyapatite. Results showed that LLLT had a positive effect on the percentage of new bone formation and on the chemical composition and crystallinity of the DO site. The DO site regeneration was confirmed by the detection of hydroxyapatite in the crystalline structure. The percentage of new bone formation was greater in the LLLT group (57. 89%) than in the control group (46. 75%) (p=0. 006). The analysis of chemical composition and of Ca and P ratios showed greater mineralization in the LLLT group. Crystallinity percentages were greater in rabbits in the LLLT group. Diffractograms showed that crystalline structures were similar to hydroxyapatite. Results showed that LLLT had a positive effect on the percentage of new bone formation and on the chemical composition and crystallinity of the DO site. The DO site regeneration was confirmed by the detection of hydroxyapatite in the crystalline structure. / O crescente uso das próteses implanto-suportadas aumentou a preocupação com a precisão de adaptação, já que a adaptação passiva é um dos fatores fundamentais para o sucesso longitudinal dessas reabilitações protéticas. O objetivo deste trabalho foi avaliar o desajuste marginal de infra-estruturas metálicas de prótese fixa sobre implantes, antes a após a retificação manual, como o teste do parafuso único, utilizando como grupo controle cilindros pré-usinados. Foram confeccionadas 10 infra-estruturas em liga de cobalto-cromo (Co-Cr), simulando uma prótese fixa de três elementos sobre dois implantes. Para isso, utilizou-se uma matriz metálica simulando a disposição clínica de implantes osseointegrados na região dos dentes 14 e 16, contendo pilares Micro-Unit. Cinco infra-estruturas foram confeccionadas com cilindros pré-usinados. As outras cinco foram confeccionadas com cilindros calcináveis, que após avaliação inicial, sofrem retificação manual das bordas de assentamento do cilindro após fundição, formando o terceiro grupo. Todas as infra-estruturas receberam soldagem a laser. As leituras do desajuste marginal foram realizadas através de imagens do microscópio eletrônico de varredura, utilizando a técnica do parafuso único, totalizando 25 medições em cada cilindro. As médias de desajuste marginal de cada cilindro foram utilizadas para a análise estatística. A análise de variância com nível de significância de 5% foi utilizada para avaliar o efeito da retificação manual entre os três grupos testados, nos cilindros com e sem parafuso. Foi concluído que os procedimentos de retificação manual não alteraram significativamente os valores de desajuste marginal nas infra-estruturas fundidas em Co-Cr, ou seja, não aumentaram a passividade das peças protéticas sobre os pilares.
572

Avaliação da carga inorgânica de resinas compostas de conteúdo nanométrico

Hörlle, Lucas January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:14Z (GMT). No. of bitstreams: 2 000418300-0.pdf: 3151523 bytes, checksum: aeea57ce4111e17b6c94b365bb2412d1 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was to analyse the filler content of composites resins with nanomeric content. It was determined the filler weight content into each material (TGA); inorganic filler by scanning-electron microscopy (SEM), their dimensions and morphology; besides weight compounds with energy dispersed X – ray test. The composites Esthet X, Filtek Supreme XT and Grandio were divided in six groups according their commercial mark and color. Filler content´s values varied from 75,75 to 87 Wt%, to Esthet X D group and Grandio E group, respectively. To EDX test, O and Si elements were observed in all of groups. Al was observed into the composites Esthet X and Grandio groups and Ba was not observed in groups of Grandio E, Filtek Supreme E and Filtek Supreme D. The results obtained about means values (μm) were: Esthet X E – 1,16B; Esthet X D – 1,39B; Filtek Supreme E – 0,6B; Filtek Supreme D – 1,14AB; Grandio E – 2,05AB e Grandio D – 3,1A. At the morphology of particles analyses, the composites resins Esthet X and Grandio showed similar characteristics with a high quantity of irregular inorganic particles and heterogeneous morphology. In the other hand, the groups of Filtek Supreme XT composites presented different characteristics among the other groups and similar into their own groups. These groups showed a high quantity of spherical and regular particles, with homogeneous distribution and sizes. The results presented different inorganic particles morphology and sizes, independent of the type of the composite. It could be concluded that composite resins presented physical characteristics of shape and size of inorganic particles that is not always coincident with manufacturer and literature. / O objetivo deste estudo foi analisar a carga inorgânica de resinas compostas de conteúdo nanométrico. Foi determinando o conteúdo de carga em peso incorporado a cada material (TGA), o conteúdo inorgânico através da microscopia eletrônica de varredura (MEV), suas dimensões e morfologia, além dos componentes em peso pelo teste de Espectrografia por Dispersão de Raios X (EDS). As resinas compostas Esthet X, Filtek Supreme XT e Grandio foram divididas em seis grupos de acordo com a marca da resina composta e a cor. Os valores do conteúdo de carga variaram de 75,75 a 87 Wt% para o grupo Esthet X D e o grupo Grandio E, respectivamente. À análise por EDS, os elementos O e Si foram observados em todos os grupos. Al foi observado nos grupos das resinas compostas Esthet X e Grandio e Ba não foi observado nos grupos Grandio E, Filtek Supreme E e Filtek Supreme D. Os resultados obtidos sobre os valores médios (μm) foram: Esthet X E – 1,16в; Esthet X D – 1,39в; Filtek Supreme E – 0,6в; Filtek Supreme D – 1,14в; Grandio E – 2,05Aв e Grandio D – 3,1A. Na análise da morfologia das partículas, as resinas compostas Esthet X e Grandio apresentaram características semelhantes entre si com grande quantidade de partículas de carga inorgânica irregulares, de morfologia heterogênea. Por outro lado, os grupos da resina Filtek Supreme XT apresentaram características diferentes das demais e semelhantes entre si, quanto à morfologia. Evidenciaram grande quantidade de partículas de carga inorgânica esféricas, regulares, com distribuição e tamanho homogêneos. Os resultados mostraram diferentes formas e tamanhos de partículas inorgânicas, independente do tipo de resina composta. Pôde-se concluir que as resinas compostas apresentaram características físicas de forma e tamanho das partículas de carga inorgânica nem sempre coincidindo com as apresentadas pelos fabricantes e comprovada pela literatura.
573

Comparação de propriedades mecânicas e do conteúdo de carga de cinco resinas compostas com nanopartículas

Pires, Luiz Antonio Gaieski January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:19Z (GMT). No. of bitstreams: 2 000402875-0.pdf: 1268537 bytes, checksum: d69e79b0f145ba87098e8a6bb0aa9e58 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aims of this study were evaluate and compare selected mechanical properties (diametral tensile strength and microhardness) and filler content of five current composites in A2 enamel and dentin shades. The tested composites were: 4Seasons (4S), Ivoclar Vivadent; Esthet-X improved (EX), Dentsply; Filtek Supreme (SU), 3MESPE; Grandio (GR), Voco and Palfique Estelite (PE), Tokuyama Dental Corp. For each group, diametral tensile strength (n=10), Knoop microharndess (n=10) and the weigth filler content were recorded. The amount of filler was obtained by termogravimetric analysis (TGA). Data were compared statistically with ANOVA and Tukey (a = 0. 05). The averages for diametral tensile strength (MPa) were: 4S dentin 36. 08b and 4S enamel 39. 26 ab ; EX dentin 44. 44 ab and EX enamel 45. 12 ab; GR dentin 45. 23 ab and GR enamel 49. 24 a ; SU dentin 46. 86 ab and SU enamel 48. 25 ab ; PE dentin 38. 69 ab ; PE enamel 38. 58 ab (p < 0. 05). The averages for Knoop microhardness (KHN) were: 4S dentin 61. 6b and 4S enamel 57. 98b ; EX dentin 73. 6b and EX enamel 54. 45b; GR dentin 123. 90a and GR enamel 74. 89b ; SU dentin 101. 30a and SU enamel 123. 10a ; PE dentin 55. 9b ; PE enamel 61. 70b (p < 0. 05). For weigth filler content (wt%): 4S dentin 75. 84 and 4S enamel 76. 37 ; EX dentin 76. 80 and EX enamel 75. 75 ; GR dentin 86. 89 and GR enamel 87. 00 ; SU dentin 76. 22 and SU enamel 76. 54 ; PE dentin 71. 62; PE enamel 70. 56.There was statistical difference between the composites within the different testes (p < 0. 05). The tested composites had not similar behavior for diametral tensile strength and Knoop microhardness. Significant differences were not observed when enamel and dentin shades were compared although Grandio in microhardness test. The highest diametral tensile strength was recorded to Grandio enamel and 4 Seasons dentin showed the lowest average (p < 0. 05). For Knoop microhardness, Filtek Supreme in both shades sowed the highest averages in comparison to other groups (p < 0. 05). / O objetivo deste estudo foi avaliar e comparar as propriedades mecânicas selecionadas (resistência à tração diametral, microdureza Knoop) e conteúdo de carga em peso pela análise termogravimétrica (TGA) de cinco marcas comerciais de resina composta diferentes em matriz orgânica e carga nas cores A2 esmalte e dentina: 4Seasons (4S), Ivoclar Vivadent; Esthet-X improved (EX), Dentsply; Filtek Supreme (SU), 3MESPE; Grandio (GR), Voco e Palfique Estelite (PE), Tokuyama Dental Corp. Para cada grupo, a resistência à tração diametral (n=10), a microdureza Knoop (n=10) e o conteúdo de carga em peso pela análise termogravimétrica foram determinados. Os resultados obtidos nos ensaios foram comparados estatisticamente com análise de variância e Tukey (J = 0,05). As médias obtidas para resistência à tração diametral (MPa) foram: 4S dentina 36,08 b e 4S esmalte 39,26 ab ; EX dentina 44,44 ab e EX esmalte 45,12 ab ; GR dentina 45,23 ab e GR esmalte 49,24 a ; SU dentina 46,86 ab e SU esmalte 48,25 ab ; PE dentina 38,69 ab ; PE esmalte 38,58 ab (p < 0,05). As médias obtidas para microdureza Knoop (KHN) foram: 4S dentina 61,6b e 4S esmalte 57,98b; EX dentina 73,6b e EX esmalte 54,45b; GR dentina 123,90a e GR esmalte 74,89b ; SU dentina 101,30a e SU esmalte 123,10a ; PE dentina 55,89b ; PE esmalte 61,70b (p < 0,05). Para o conteúdo de carga em peso (wt%): 4S dentina 75,84 e 4S esmalte 76,37; EX dentina 76,80 e EX esmalte 75,75 ; GR dentina 86,89 e GR esmalte 87,00 ; SU dentina 76,22 e SU esmalte 76,54 ; PE dentina 71,62; PE esmalte 70,56. Os compósitos testados não apresentaram comportamento mecânico similar quanto à resistência à tração diametral e microdureza Knoop.Não foi observada diferença quando as pastas esmalte e dentina foram comparadas com exceção da resina Grandio no teste de microdureza. A maior resistência à tração diametral foi observada para a Grandio esmalte enquanto a 4 Seasons dentina apresentou a mais baixa média (p < 0,05). No teste de microdureza Knoop, a resina Filtek Supreme em ambas as pastas e a Grandio dentina apresentaram as maiores médias em comparação aos demais grupos (p < 0,05).
574

Análise local e sistêmica das reações tissulares a diferentes materiais utilizados em pulpotomias: estudo em ratos

Follmann, Carina Staudt January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:19Z (GMT). No. of bitstreams: 2 000434141-0.pdf: 4096445 bytes, checksum: 46ea01752aceb50c79baf98a79715628 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Introduction: The aim of this study was to evaluate the subcutaneous connective tissue reaction and the organs liver and kidney to mineral trioxide aggregate (MTA), paste of calcium hidroxyde (CH) and formocresol (FC). Methods: Polyethylene tubes containing the test materials and empty tubes (control group) were implanted in the subcutaneous tissue of 46 rats. After 7 and 21 days, observations on back were made for inflammatory alterations, fibrous condensation, abscess formation and foreign body, and, on liver and kidney, were made for steatosis, apoptosis, inflammation, vascular changes and hipercellularity. Comparisons between groups and periods of time were made using the Kruskal-Wallis, Post-hoc and Mann- Whitney tests. Results: MTA and CH groups showed a behavior similar in inflammatory alterations to that of the control group in 21days, in contrast of FC group that presented statistically significant difference to that of other groups. In FC group, there was no formation of fibrous capsule and formation of abscess, in 21 days. In all groups, alterations in liver and kidney were observed. Conclusion: MTA and CH groups showed a behavior similar in all evaluated events. FC group presented unfavorable results. Tissue alterations were observed in liver and kidney. / Introdução : O objetivo deste estudo foi avaliar, em ratos, a reação do tecido conjuntivo subcutâneo, e dos órgãos fígado e rim, a materiais utilizados em pulpotomias: agregado trióxido mineral (MTA), pasta de hidróxido de cálcio (HC) e formocresol (FC). Métodos: Tubos de polietileno vazios (grupo controle) e contendo os materiais de teste foram implantados no tecido subcutâneo de 46 ratos. Após 7 e 21 dias, as observações no dorso foram feitas para alterações inflamatórias, condensação fibrosa, formação de abscesso e corpo estranho e, no fígado e rim, foram avaliadas esteatose, apoptose, inflamação, alterações vasculares e hipercelularidade. Comparações entre os grupos e períodos de tempo foram feitas usando o teste de Kruskal-Wallis, Post-hoc e Mann-Whitney. Resultados: Os grupos MTA e HC mostraram um comportamento semelhante ao do grupo controle, nas alterações inflamatórias em 21 dias, ao contrário do grupo FC, o qual apresentou diferença estatisticamente significante em relação aos outros grupos. No grupo FC, não houve formação de cápsula fribrosa e houve formação de abscesso, em 21 dias. Em todos grupos, alterações no fígado e rim foram observadas. Conclusão: Os grupos MTA e HC mostraram um comportamento similar em todos os eventos analisados. O grupo FC apresentou resultados não favoráveis. Foram observadas alterações tissulares no fígado e rim.
575

Análise comparativa da precisão de adaptação entre componentes UCLA e implante de um mesmo sistema

Bondan, João Lopes January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:20Z (GMT). No. of bitstreams: 2 000390167-0.pdf: 8479233 bytes, checksum: 78f267d7711851d94f32594d0a86c23d (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the fit between the components UCLA and implant of the same system (Neodent). The comparison was made through an evaluation of the vertical and horizontal gaps present at the interface between implant and UCLA, through scanning electronic microscopy (SEM), measurements in selected locations. Statistical analysis was done through variance analysis procedure (Anova-Oneway) and Tukey´s posterior procedure, with a significance level of 5%. The results pointed the UCLA components present significant differences in many evaluated aspects. Such differences might have some influence in the use of these components, both in clinical results and in its predictability. / O objetivo deste estudo foi avaliar a precisão de adaptação entre componentes UCLA e implante de um mesmo sistema (Neodent). A análise foi através da avaliação da fenda vertical e da discrepância horizontal da interface implante-UCLA por microscopia eletrônica de varredura (MEV), das mensurações em locais indicados. Para a comparação dos resultados, foi utilizado o procedimento de análise de variância (Anova-Oneway) e o procedimento posterior de Tukey, ao nível de significância de 5%. Os resultados mostraram que os componentes UCLA avaliados possuem diferenças significantes em diversos pontos avaliados. Essa variabilidade nos resultados podem interferir na eficácia de uso desses componentes, nos resultados clínicos e na sua previsibilidade.
576

Avaliação da citotoxicidade e da liberação iônica de mini-implantes ortodônticos

Blaya, Micéli Beck Guimarães January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:23Z (GMT). No. of bitstreams: 2 000419964-0.pdf: 1028721 bytes, checksum: 6c934b5641f1910681c7e4e7f278caa4 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to investigate the biocompatibility of new and corroded miniscrews (MSs) through the evaluation of cell toxicity in vitro and of ion release in vivo. Saccharomyces Cerevisiae yeast was used as a eukaryotic microbiological model for the cytotoxicity assay. Qualitative and quantitative tests were carried out using the wild strain FF18733. In addition, direct exposure (in liquid YPD culture) and indirect exposure tests (using artificial saliva previously exposed to the MSs) were carried out using new MSs and MSs with sodium fluoride (NaF at 0. 0125%, 0. 025% and 0. 05%) and used in vivo. Photomicrographs with scanning electron microscopy (SEM) were obtained for the new and used MSs. As a result, the wild strain FF 18733 showed a reduction in cell viability in the direct exposure to one and two new MSs. However, this reduction was not significant. The results for indirect exposure showed that there were no significant differences between new and used MSs and the control groups. Moreover, exposure to NaF did not induce corrosion of MSs sufficient to lead to significant cell toxicity in the yeast. Despite the slight corrosion revealed by the photomicrographs, there was no significant loss of cell viability in the strains of S. cerevisiae tested. This demonstrates that the components of MSs (Ti-6Al-4V) did not significantly alter the yeast metabolism, indicating that the MSs tested present good biocompatibility for use in orthodontic clinics. The aim of the in situ study was to compare the levels of several metallic ions released in the saliva of patients undergoing orthodontic treatment with MSs. The experimental group was made up of 20 individuals who were within the 6th and 8th months of treatment. Saliva from each patient was collected at four different timepoints: before MS placement (T1), 10 minutes (T2), 7 days (T3) and 30 days (T4) after MS placement. Saliva samples were analyzed by spectrometry (ICP- MS - inductively coupled plasma mass spectrometry; and ICP-OES - inductively coupled plasma optical emission spectrometry).The release of nine different metal ions was observed: titanium (Ti), zinc (Zn), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), aluminum (Al), vanadium (V), and cobalt (Co). Data were analyzed by descriptive statistics and tests for normality (Shapiro-Wilk). The metal ion concentrations in the saliva at the four different timepoints were compared using the Wilcoxon test (α=95%). At T4, there was a quantitative increase in the salivary concentration of Cu, Ti, V and Zn and a quantitative decrease in Al, Co, Cr, Fe and Ni, when compared to T1. However, there were no statistically significant differences in the metal concentrations. Therefore, it can be concluded that the use of orthodontic appliances with MSs does not lead to an increase, significative statistically, in salivary metal concentrations. / Propôs-se neste trabalho avaliar a biocompatibilidade dos mini-implantes ortodônticos novos e utilizados em tratamento ortodôntico por meio da aplicação de testes avaliativos de toxicidade celular in vitro e de liberação iônica in vivo. O ensaio de citotoxicidade foi através da levedura Saccharomyces Cerevisiae que é um modelo microbiológico eucariótico. Foram realizados testes qualitativos e quantitativos, com a cepa selvagem FF18733 desta levedura. Foram executados testes de exposição direta (em meio de cultura YPD líquido) e testes de exposição indireta utilizando: MIs novos, MIs expostos ao fluoreto de sódio (NaF a 0,0125%, 0,025% e 0,05%), e MIs utilizados in vivo. Foram realizadas fotomicrografias com microscopia eletrônica de varredura (MEV) nos MIs utilizados in vivo e novos. Como resultado, a cepa selvagem FF 18733 mostrou uma diminuição de sua sobrevivência nos experimentos de exposição direta a um e a dois mini-implantes novos. No entanto, tal sensibilidade não se mostrou significativa. Os resultados de exposição à saliva artificial de novos, bem como todos os resultados referentes aos usados, não indicaram diferenças em relação aos controles. Da mesma forma, a exposição ao NaF não induziu, nos MIs, uma corrosão suficiente para causar toxicidade celular significativa nesta levedura. Apesar da corrosão leve apresentada nas fotomicrografias, não foram observadas induções de perda de viabilidade celular significativas na cepa testada de S. cerevisiae a partir dos componentes da liga (Ti-6Al-4V) dos MIs ortodônticos. Evidenciou-se, assim, que tais componentes não alteram de forma importante o metabolismo da levedura, indicando que os MIs testados tendem a apresentar uma boa biocompatibilidade para uso em clínica ortodôntica. No estudo in situ, o objetivo foi examinar e comparar os níveis de vários íons metálicos liberados na saliva de pacientes em tratamento ortodôntico e que iriam necessitar de tratamento envolvendo o uso de miniimplante. A amostra foi composta por 20 indivíduos que estavam entre o sexto e o oitavo mês de tratamento ortodôntico. A saliva de cada paciente foi coletada em 4 tempos diferentes: antes da inserção do MI (T1), 10 minutos (T2), 7 dias (T3) e 30 dias (T4) após a instalação do MI. As amostras salivares foram analisadas através de espectrometria (ICP- MS - inductively coupled plasma mass spectrometry; e ICP-OES - inductively coupled plasma optical emission spectrometry). A liberação de nove diferentes ions metálicos foram observados: titânio (Ti), zinco (Zn), cromo (Cr), níquel (Ni), ferro (Fe), cobre (Cu), alumínio (Al) e cobalto (Co). Os dados foram analisados através de estatística descritiva e testes de normalidade (Shapiro-Wilk). A concentração de ions metálicos na saliva nos quatro tempos diferentes de tratamento com MI foi comparado usando o teste de Wilcoxon (α=95%). No tempo T4, houve um aumento quantitativo na concentração salivar de Cu, Ti, V, Zn, bem como um decréscimo quantitativo na concentração salivar de Al, Co, Cr, Fe, Ni, quanto comparados ao grupo T1. No entanto, não houve diferenças estatisticamente significativas entre as concentrações de metais. Logo, pode ser concluído que a colocação de aparelho ortodôntico associado ao uso de mini-implante ortodôntico não leva a um aumento, estatisticamente significativo, na concentração de ions metálicos na saliva.
577

Eficácia de dois métodos de clareamento dental e sua influência sobre as propriedades físico-químicas e sobre a resistência à união de sistemas adesivos

Marcondes, Maurem January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:29Z (GMT). No. of bitstreams: 2 000387564-0.pdf: 2940203 bytes, checksum: cf1530adcd62580b3d499dcac450127c (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / In order to fulfill the growing demand for bleaching treatments at dental clinics, several researches about different dental whitening techniques have been carried out, using bleaching agents with different concentrations and formulas. The aim of this study was to evaluate in vitro: a) the color change of human teeth bleached with 35% hydrogen peroxide associate to pigment with different wavelengths and irradiated with Nd:YAG laser or halogen curing light; b) the Vickers hardness number (VHN) of these specimens, before and after the whitening treatments; c) the enamel’s surface topography through MEV; d) the tensile strength of two adhesive systems containing acetone or ethanol; e) the fracture pattern after mechanical test of tensile bond strength using MEV. Seventy five extracted human molars had the crown split at the mesio-distal sense and the 150 fragments obtained were divided into five groups according to the bleaching agent and photo activation type: WL (Whiteness HP Maxx and Nd:YAG laser), WH (Whiteness HP Maxx and halogen light), QL (H2O2+carbopol+Q-Switch and Nd:YAG laser), QH (H2O2+carbopol+Q-Switch and halogen light) e C (Control, without bleaching treatment).The shade guide Vita color evaluation and the Vickers hardness number test were realized before and after the bleaching treatments. After two weeks of storage in artificial saliva, the groups were subdivided in order to carry out the restorative treatments, using the adhesive systems Adper Single Bond 2 and Solobond M. Right after, the tensile strength test and the analysis of the fracture pattern were made. The color varied seven tabs on the groups irradiated with the Nd:YAG laser and eight tabs on the groups irradiated with the halogen light. According to the t-student test, there were no significant difference to the VHN before or after the clearing treatments (p>0. 05). According to ANOVA, the tensile strength values did not indicate statistic difference between the tested groups and its controls, regarding the two types of adhesive tested (p>0. 05), being the mixed fail, the most frequent fracture pattern. The superficial morphology of the bleached enamel presented alteration on topography and these characteristics were not significant on tensile bond strength. In conclusion all protocols were efficient for bleaching the specimens and to the restorative procedure with composite resin after the treatment. / A fim de atender a crescente demanda por clareamento nos consultórios odontológicos, pesquisas acerca de diferentes técnicas, concentrações e fórmulas de agentes clareadores estão sendo realizadas. O objetivo desse estudo foi avaliar in vitro: A) a alteração de cor de dentes humanos clareados com peróxido de hidrogênio 35% associado à corantes com diferentes comprimentos de onda e irradiados com laser de Nd:YAG ou luz halógena; B) a microdureza Vickers (VHN) destes espécimes antes e após os tratamentos clareadores; C) topografia da superfície do esmalte pela MEV; D) a resistência de união à tração de dois sistemas adesivos, um contendo acetona e o outro etanol; E) o padrão de fratura dos corposde- prova com auxílio da MEV após o ensaio de resistência de união à tração. Setenta e cinco molares humanos extraídos tiveram a coroa seccionada no sentido mésio-distal e os 150 fragmentos obtidos foram divididos em cinco grupos conforme o agente clareador e tipo de fotoativação: WL (Whiteness HP Maxx e Laser de Nd:YAG), WH (Whiteness HP Maxx e luz Halógena), QL (H2O2+carbopol+Q-Switch e laser de Nd:YAG), QH (H2O2+carbopol+QSwitch e luz Halógena) e C (Controle, sem clareamento).A avaliação de cor pela escala Vita e o teste de microdureza Vickers foram realizados antes e depois dos tratamentos clareadores. Após duas semanas de armazenamento em saliva artificial, os grupos foram subdivididos para a realização dos tratamentos restauradores com os sistemas adesivos Adper Single Bond 2 e Solobond M e, logo após, realizado o ensaio de resistência à tração e análise do padrão de fratura. A cor variou sete níveis para os grupos irradiados pelo laser de Nd:YAG e oito níveis para os grupos irradiados pela luz halógena. De acordo com o teste t-student, não houve diferença significativa para a VHN antes e depois dos clareamentos (p>0,05). Segundo ANOVA, os valores de resistência de união não indicaram diferença estatística entre os grupos teste e seus controles para os dois tipos de adesivos testados (p>0,05), sendo o padrão de fratura mais freqüente o de falha mista. Houve alterações na superfície do esmalte, todavia, não foram significativas a ponto de modificar a resistência de união dos sistemas adesivos. Concluí-se que todos os protocolos realizados nesta pesquisa foram eficazes para o clareamento dos espécimes, bem como para o procedimento restaurador após o tratamento.
578

Influência da largura do cinzel utilizado em ensaio mecânico de cisalhamento sobre a resistência da união

Oliveira, Antônio Carlos Castellan de January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:29Z (GMT). No. of bitstreams: 2 000406879-0.pdf: 817502 bytes, checksum: a388f3f8f4ce8e84782dbb5d5932a532 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was compare the chisel width in shear bond strength test in dental/composite interface. For the shear bond test, chisels with 0. 5, 1, 2 and 3mm width were used to test four groups (n=15). Sixty bovine incisors were used, imbedded and flattened according to the methodology of Goes (1994) in order to prepare the samples. Enamel surfaces were flattened and etched with 15% phosphoric acid (3M/ESPE) with 15%, followed by application of Single Bond (3M/ESPE) adhesive system and Z-250 (3M/ESPE) composite resins according to manufacture’s instructions. To the shear bond strength, an universal testing machine EMIC DL 2000 (EMIC) at 0. 5 mm/min cross-head speed. Obtained data were compared statistically with analysis of variance and Duncan’s test with significance level of 5% (p < 0. 05) and submitted to Pearson’s correlation test (p < 0. 01). The averages in megapascal recorded were: 0. 5 mm – 19. 66; 1. 0 mm – 18. 78; 2 mm – 16. 77; 3 mm – 16. 06.There was a significantly difference between groups, when submitted to analysis of variance (p = 0. 045) and multiple comparison of Duncan’s test. The lower average (MPa) was recorded for chisel with 3 mm (16. 06), while the highest average (MPa) was recorded for the group with 0. 05 mm chisel (19. 66), that were statistically different. The correlation between chisel width and shear bond strength was significant (p < 0. 01). The obtained results allow conclude that shear bond strength (MPa) is influenced by chisel width used in the test. / O objetivo deste estudo foi comparar diferentes larguras de cinzel utilizadas em ensaios mecânicos para avaliação da resistência de união ao cisalhamento na interface esmalte dental / resina composta. Para a realização do ensaio e cisalhamento, cinzéis com larguras de 0,5mm, 1,0 mm, 2,0 mm e 3,0 mm foram utilizados para testar 4 grupos (n=15). Foram utilizados 60 dentes bovinos do grupo incisivo que tiveram sua inclusão, preparo de superfície e confecção dos corpos de prova realizados de acordo com Goes (1994). As superfícies de esmalte foram planificadas, condicionadas com ácido fosfórico (3M/ESPE) à 15%, seguido da aplicação do sistema adesivo Single Bond (3M) e de resina composta Z-250 (3M) conforme instruções do fabricante. Para o ensaio de cisalhamento foi utilizada uma máquina de ensaio universal EMIC DL 2000 (EMIC, BRASIL) a velocidade de 0,5mm/min. Os dados obtidos foram comparados estatisticamente com análise de variância e teste de Duncan com nível de significância de 5% (p < 0,05) e submetidos ao teste de correlação de Pearson (p < 0,01). As médias obtidas em Megapascal para a resistência de união ao cisalhamento foram: 0,5mm - 19,66; 1,0mm – 18,78; 2,0 mm – 16,77; 3,0 mm – 16,06. Houve diferença estatisticamente significativa entre os grupos, quando submetidos à análise de variância (p = 0,045) e testes de comparação múltipla de Duncan. A menor média (MPa) foi registrada para o grupo com cinzel de 3,0mm (16,06), enquanto a maior média (MPa) foi verificada para o grupo com cinzel de 0,5mm (19,66), que diferiram estatisticamente. A correlação entre largura do cinzel e resistência de união foi significante (p < 0,01). Os resultados obtidos permitem concluir que os valores (MPa) de resistência de união ao cisalhamento sofrem influência da largura do cinzel utilizado no ensaio.
579

Avaliação da pré-carga e torque de remoção de 3 tipos de parafusos de fixação de pilares para próteses unitárias implanto-suportadas

Stüker, Rafael Augusto January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:30Z (GMT). No. of bitstreams: 2 000346916-0.pdf: 3129380 bytes, checksum: 19e63ec2b78c6ba60d946c3cb69dd9c4 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Several authors consider the mechanical problems of fracture and components loosening as the main causes of failure in implant-supported rehabilitation. Most of these difficulties are related to insufficient induced tension of the screw for transmucosal abutment setting, known as preload. This study was aimed to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque values. Three external hex fixtures (Conexão® ,Sistemas de Prótese Ltda., São Paulo, Brazil) presenting 4. 0mm in diameter and 15mm in length were used, and each received a transmucosal abutment (Cera One®) for single-unit prosthesis, which was fixed to the implant with the respective screw: Group A- gold screw, Group B- titanium screw, and Group C- surface-treated titanium screw (Ti-Tite®). Ten screws of each type were attached with 30,07±0,28Ncm torque and maintained in position for 5 minutes. After the fixation, the preload values were measured through strain gauge and a measurement cell. Initial and removal torques were measured with an electronic torque control device. Gold screws exhibited higher preload values (131,72±8,98N), followed by surfacetreated titanium screws (97,78±4,68N), and titanium screws presented the lowest results (37,03±5,69N). The following data were found for removal torque: gold: 17,64±1,12Ncm; titanium: 18,75±1,89Ncm; surface-treated titanium: 16,43±1,33Ncm. After application of Analysis of Variance (ANOVA, p<0,05) and Tukey (p<0,05) comparison statistical test, significant differences were found between groups, for both preload and removal torque values. In conclusion, gold screws might be indicated to achieve superior longevity of the abutment-implant union and consequently prosthetic restoration due to greater preload values yielded. / Inúmeros autores consideram os problemas mecânicos de fratura ou afrouxamento de componentes como sendo uma das principais causas de insucessos em reabilitações implanto-suportadas, estando muitos destes problemas relacionados a uma tensão insuficientemente induzida ao parafuso para fixação de pilar transmucoso, também conhecida como pré-carga. Assim, este estudo in vitro teve como objetivo comparar a pré-carga de 3 tipos diferentes de parafuso para fixação de pilares transmucosos utilizados em próteses unitárias implanto-suportadas através de extensiometria e valores de torque de remoção. Foram utilizados 3 implantes de hexágono externo (Conexão®, Sistemas de Prótese Ltda., São Paulo, Brasil) com 4,0mm de diâmetro por 15mm de comprimento, sendo que cada um recebeu um pilar transmucoso tipo Cera One® para prótese unitária cimentada, que foi fixado ao implante com seu respectivo parafuso de ouro (Grupo A), titânio (Grupo B) e titânio com tratamento superficial (Ti-Tite®) (Grupo C). Dez parafusos de cada tipo foram fixados com um torque de 30,07±0,28Ncm e mantidos em posição por 5 minutos. Após a fixação, foi avaliado o valor de pré-carga produzido com a utilização de extensiometria e uma célula medidora. Para a medição do torque inicial e do torque de remoção foi utilizado um dispositivo eletrônico de controle de torque. Os parafusos de ouro apresentaram os maiores valores de pré-carga (131,72±8,98N), depois os de titânio com tratamento de superfície (97,78±4,68N) e os de titânio apresentaram os menores valores (37,03±5,69N). Para os valores de torque de remoção foram encontrados os seguintes resultados: ouro: 17,64±1,12Ncm; titânio: 18,75±1,89Ncm; titânio com tratamento de superfície: 16,43±1,33Ncm. Após análise de variância (ANOVA, p<0,05) e o teste estatístico de Tukey (p<0,05) foram encontradas diferenças significativas entre os 3 grupos tanto para os valores de pré-carga como para os de torque de remoção. Os resultados do presente estudo sugerem que os parafusos de ouro são os mais indicados para que se atinja uma maior longevidade da união pilar-implante e conseqüentemente da restauração protética em vista dos maiores valores de pré-carga produzidos.
580

Análise comparativa da microinfiltração marginal em ápices retro-obturados com MTA e cimento Ionômero de vidro

Hellwig, Ingeburg January 2005 (has links)
Made available in DSpace on 2011-12-27T14:14:30Z (GMT). No. of bitstreams: 2 000342794-0.pdf: 1868872 bytes, checksum: 69d37d7562fb1d7b65e4a9f9cb3dc939 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of periapical surgery is to remove persistent periapical disease. This procedure consists of exposure and excision of the affected dental apex, rootend cavity preparation, and retrograde filling with a sealing material. This in vitro study used apical microleakage testing, 0. 2% Rhodamine B dye penetration, and computer-assisted morphometry to evaluate 30 endodontically-treated, single-rooted permanent human teeth divided in three groups. Specimens in the three groups underwent apicoectomy with bur at a 90-degree cutting angle, ultrasonic root-end cavity preparation, and retrograde filling with one of three sealing materials: group A – MTA Angelus ® ; group B - Vitremer ® ; group C - ProRoot ® MTA. Vitremer ® had the best results in the comparative analysis. The two MTA materials had similar results. Results for the three materials under study were satisfactory for apical retrograde filling. / As cirurgias paraendodônticas expõem e removem ápices dentais, promovem retrocavitações no longo eixo dos canais radiculares e as retro-obturam com materiais que promovem seu selamento. Esta pesquisa avaliou in vitro, por intermédio do teste de microinfiltração apical, por corante Rodamina B a 0,2 % e morfometria computadorizada, 30 dentes humanos permanentes unirradiculares, submetidos a tratamento endodôntico e divididos em três grupos: A - apicectomia por broca em 90 graus, retrocavidade com ultra-som e retro-obturação com MTA Angelus® ; B - apicectomia por broca em 90 graus, retrocavidade com ultra-som e retro-obturação com Vitremer®; C - apicectomia por broca em 90 graus, retrocavidade com ultra-som e retro-obturação com MTA ProRoot®. A análise comparativa, por meio dos testes estatísticos de Kolmogorov-Smimov, Coeficiente de Correlação de Pearson e Análise de Variância, complementada pelo teste de Tukey, demonstrou que, com o Vitremer®, se obtiveram os melhores resultados, enquanto os dois materiais MTA apresentaram resultados equivalentes. Pode-se considerar os três materiais testados satisfatórios como retro-obturadores apicais.

Page generated in 0.128 seconds