• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 568
  • 164
  • 20
  • 18
  • 18
  • 17
  • 17
  • 10
  • 10
  • 9
  • 9
  • 8
  • 4
  • 4
  • 2
  • Tagged with
  • 814
  • 814
  • 518
  • 484
  • 154
  • 137
  • 127
  • 114
  • 101
  • 85
  • 80
  • 77
  • 75
  • 74
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Stability change of chemically modified SLA titanium palatal implants : a randomized controlled clinical trial /

Balbach, Ulrike Margarethe. January 2009 (has links)
Diss. med. dent. Zürich. / Literaturverz.
202

Surface characteristics and in vitro bio-acceptability of machined and cast pure titanium and titanium alloy /

Carneiro, Lorna Celia. January 2003 (has links)
Thesis (D.Phil.(Dentistry))--Faculty of Health Sciences)-University of Pretoria, 2003. / Summary in English. Includes bibliographical references. Also available online.
203

Onlay bone grafts and implants in the reconstruction of severely resorbed maxillae a one-stage procedure /

Nyström, Elisabeth. January 1995 (has links)
Thesis (Doctoral)--Umeå University, Sweden, 1995. / Added t.p. with thesis statement inserted. Includes bibliographical references.
204

Characterization of the interface between prefabricated dental implant component and cast dental alloys

Sanli, Yurdanur, January 2007 (has links)
Thesis (Ph. D.)--Ohio State University, 2007. / Title from first page of PDF file. Includes bibliographical references (p. 147-151).
205

Análise de corrosão, dureza e fratura de conjuntos implantes / componentes protético de Titânio c.p., após serem submetidos a ciclos de fadiga em um meio fluoretado com diferentes PH /

Vaz, Luis Geraldo. January 2007 (has links)
Resumo: Atualmente o titânio é empregado como biomaterial devido à sua biocompatibilidade e resistência à corrosão. Entretanto, íons fluoretos, freqüentemente empregados em dentifrícios bucais, podem interferir no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de fadiga, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, 7,4 e 5,3, mediante imersão das amostras nesses meios durante 184 horas e também em água destilada, grupo controle. As amostras foram testadas num durômetro Micromet 2001 (500gf/30s). Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de fadiga realizados em uma máquina de ensaios mecânicos MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV foram constatadas evidências de corrosão na superfície das amostras após ação de íons fluoretos, entretanto pelo EDS não se verificou incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas. / Abstract: Titanium has been widely used as biomaterial owing to its excellent corrosion resistance, mechanical properties and biocompatibility. However, it has been reported that fluoride-containing environments can attack titanium. The aim of this study was evaluated fluoride environments influence with different pH values in the implant/abutment sets. The implants were separated into 3 groups containing 7 implants/brand: one was submerged in acid fluoride environment (NaF 1500ppm 184h pH 5.3), one in neutral fluoride environment (NaF 1500ppm 184h pH 7.4), and other group in distillated water, simulating five years of dental hygiene. Hardness and surface texture were evaluated before and after fluoride exposition by Vickers method (500gf/30s) and scanning electron microscopy (SEM), respectively. The fatigue test was performed with 100.000 load cycles, 15 Hz and 150 N. There was decrease in hardness in implants submitted to the fluoride environment. SEM and EDS evaluation showed dark stains in all implants, irrespective of fluoride pH, resulting from pitting corrosion process. All sets supported the fatigue test until 100.000 load cycles. The results demonstrated that fluoride environment there was no influence in mechanical properties of the implant/abutment sets.
206

Avaliação da distribuição das tensões em prótese do tipo "All on Four" : estudo pelo método dos elementos finitos tridimensionais /

Amoroso, Andressa Paschoal. January 2013 (has links)
Orientador: Humberto Gennari Filho / Co-orientador: José Vitor Quinelli Mazaro / Banca: Fellippo Ramos Verri / Banca: Ricardo Shibayama / Resumo: Considerando o aumento crescente e contínuo da demanda por tratamento protético reabilitador sobre implantes, aliado ao sucesso comprovado dos implantes osseointegrados, fazem com que a procura de meios possam fortalecer ainda mais este tipo de tratamento, seja abundante, principalmente no que diz respeito à distribuição das forças. Proposta: o objetivo desse trabalho foi analisar a distribuição das tensões geradas em diferentes configurações da prótese tipo protocolo, através do método dos elementos finitos tridimensionais. Materiais e método: para a realização deste estudo foram confeccionados 2 modelos mandibulares com auxílio dos programas de modelagem gráfica SolidWorks 2010 (SolidWorks Corp, Massachusetts, EUA) e Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA). Cada modelo representou uma mandíbula com prótese protocolo sobre implantes de hexágono externo 4,0 x 13,0mm (Master, Conexão Sistemas de Prótese Ltda., São Paulo, Brasil) localizados na região interforaminal, variando a inclinação. Modelo 1: prótese com 4 implantes dispostos perpendicularmente à crista do rebordo e modelo 2: prótese do tipo All on four (implantes distais inclinados em 30º). A representação da prótese foi em resina acrílica e a infra estrutura metálica em NiCr. Os desenhos tridimensionais foram exportados ao programa de elementos finitos FEMAP 11.0 para geração da malha. A carga axial aplicada foi de 300N, bilateral sendo 75N em cada dente, e a oblíqua 150N, unilateral sendo 75N em cada dente, em 1º pré-molares e 1º molares. Resultado: após a análise no programa NEiNastran® 9.2 (Noran Engineering, Inc., EUA), os resultados foram... / Abstract: The increasing and continuous demand for implants prosthetic rehabilitation along with the proven success of dental implants make that search for means which can further strengthen this type of treatment is abundant, especially regarding the distribution of forces. Purpose: The aim of this study was to analyze the stress distribution generated in different configurations of the full-arch implant-supported prostheses, through the three-dimensional finite element method. Material and method: For this study two mandibular models were made using the graphical modeling program SolidWorks 2010 (SolidWorks Corp., Massachusetts, USA) and Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA). Each model represented a jaw with a full-arch implant-supported prosthesis using external hexagon implants with 4.0 x 13.0 mm (Master Connection Implant Systems Ltda., São Paulo, Brazil) located in the interforaminal region, varying the inclination. Model 1: prosthesis with 4 implants arranged perpendicularly to the ridge crest and model 2: All-on-four prosthesis (distal implants tilted at 30 °). The representation of the prosthesis was with acrylic resin and the metallic infrastructure with NiCr. The three-dimensional images were exported to finite element programs FEMAP 11.0 for mesh generation. The axial load applied was 300N, being 75N bilateral in each tooth, and oblique of 150N, being 75N unilateral in each tooth, in 1st premolars and 1st molars. Results: After analysis at the program NEiNastran® 9.2 (Noran Engineering, Inc., EUA), the results were visualized through individualized maps of von Mises stress and main maximum stress on each model. It can be observed in the model with tilted implants, that for both loads the stress concentrations were higher. Conclusion: It was concluded that the All on four prostheses presented highest stress concentrations, especially in the region of the distal implant. / Mestre
207

Avaliação da eficácia de um gel de vedação no selamento da interface pilar/implante e na manutenção da pré-carga dos parafusos de retenção /

Seloto, Camila Berbel. January 2017 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Juliana Aparecida Delben / Resumo: Esse estudo avaliou a eficácia de um material de vedação na manutenção da pré-carga em parafusos de retenção bem como o desajuste pilar/implante e microinfiltração após ciclagem mecânica. Foram formados seis grupos (n=12) sendo, um grupo teste (T) e um grupo controle (C) para cada tipo de conexão pilar/implante (conexão hexagonal externa (HE) e pilares UCLA; conexão cone Morse (CM) e pilares UCLA; e conexão CM e pilares flexcone (FC)). Nos grupos testes (HET, CMT e FCT) foi aplicado um agente de vedação no parafuso de retenção, enquanto os grupos controle (HEC, CMC e FCC) foram mantidos da forma convencional. Todos os implantes foram embutidos em poliuretano e foram introduzido 0,7μl de Azul de Toluidina (AT) na porção mais profunda de cada um deles. Em seguida, os pilares foram posicionados sobre os implantes e parafusados com o torque recomendado pelo fabricante com auxílio de chave especifica e um torquímetro digital. Formados os corpos-de-prova, estes foram submetidos à ciclagem mecânica (1x106 ciclos), com frequência de 2Hz e carregamento oblíquo de 130N. As avaliações dos desajustes foram realizadas em um estereomicroscópio antes e após a ciclagem mecânica. Para verificar a capacidade de vedação do agente após a ciclagem mecânica foi desenvolvida uma curva padrão, na qual determinou-se a diluição de azul de toluidina (AT). Em seguida, os dados foram analisados em espectrofotômetro para a formação da curva padrão. Na sequência, os corpos-de-prova foram colocadas individu... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effectiveness of a sealing material in preload maintaining of retaining screws and the misfit on implant / abutment interface after mechanical cycling. It was formed six groups (n=12), being one test group (T) and other control group (C) for each type of abutment / implant connection (external hexagonal connection (EH) and UCLA abutments, Morse taper (MT) and UCLA abutments, and CM connection and flexcone (CF) abutments). In the test groups (EHT, MTT and CFT) a sealing agent was applied on the retention screw, whereas the control groups (EHC, MTC and CFC) were maintained in the conventional manner. All implants were embedded in polyurethane and into the deeper portion of each implant it was introduced 0.7 μl of Toluidine Blue (TB). After that, the abutments were screwed to the implants with the torque values recommended by the manufacturer with the aid of a specific wrench and a digital torque wrench. The specimens formed were submitted to mechanical cycling (1x106 cycles) with frequency of 2Hz and oblique loading of 130 N. The misfit evaluation were performed at a stereomicroscope before and after a mechanical cycling. In order to verify the gel sealing ability after the mechanical cycling a standard curve was performed to determine the blue toluidine (TB) dilution. Then the data obtained were analyzed in a spectrophotometer for a standard curve formation. Afterwards, the specimens were placed in vials containing 400μl of distilled water. The spectrophotometric analysis was performed at 8 different times (1, 3, 6, 24, 48, 72, 96 and 144 hours). Finally, measurements of final destorque values (post-cycling) were performed. The misfit data, destorque and dye release (sealing ability) were obtained and submitted to normality statistical tests and then analyzed by ANOVA and Tukey tests (α = 0.05). The ANOVA... / Mestre
208

Avaliação das microdeformações ao redor de implantes, na utilização de pilares protéticos retos e angulados 17° e 30°, sob a influência de aplicação de cargas /

Rodrigues, Vinícius Anéas. January 2017 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Sergio Eduardo de Paiva Gonçalves / Banca: Alfredo Mikail Melo Mesquita / Banca: Lucilene Hernandes Ricardo / Banca: Luis Gustavo Oliveira de Vasconcellos / Resumo: O objetivo deste estudo in vitro foi analisar a distribuição das microdeformações geradas ao redor de implantes de hexágono externo, sob a influência da utilização de intermediários do tipo mini pilares cônicos retos e angulados 17° e 30°, sob cargas axiais e não axiais, por meio da análise de elementos finitos e extensometria. Os modelos tridimensionais foram criados simulando três blocos de poliuretano, os quais receberam três implantes cada, um grupo perpendicular e outros dois com fixações inclinadas em 17° e 30°. Para o estudo também foram modelados os intermediários do tipo mini pilar cônico reto e angulados e uma supraestrutura metálica padronizada para ambos os grupos, os materiais foram considerados homogêneos, isotrópicos e lineares. Após a confecção, as geometrias foram exportadas em malhas para o software de análises (ANSYS 15.0, ANSYS Inc., Houston, USA), um carregamento axial de 30 kgf foi aplicado e os valores de tensão e as microdeformações foram analisados. Para análise in vitro, foram confeccionados blocos idênticos aos desenhados anteriormente. Foram colados sete extensômetros na superfície dos blocos, quatro tangenciando cada um dos implantes e três na transversal dos implantes. Coifas plásticas foram adaptadas a um enceramento padronizado e depois fundidas. A supraestrutura metálica foi parafusada com torque de 10 N.cm. Para aplicação de cargas foi utilizado um dispositivo de aplicação de cargas (DAC) com uma carga de 30 kgf. durante 10 segundos. Os dados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vitro study was to analyze microstrains distribuition generated around external hexagon implants, under the influence of intermediary prosthetic componentes as straight, 17° and 30° angled miniconical abutments, under axial and non-axial loads, by finite elements and strain-gauge analysis. The three-dimensional models were created simulating three polyurethane blocks, being installed three implants each, one perpendicular group and another two with inclined fixations at 17° and 30°. For the study were also created straight and angled miniconical abutments and a standardized metallic superstructure for both groups. The materials were considered symmetrical, isotropic and solid. After the preparation, the geometries were exported in mesh to the analysis software (ANSYS 15.0, ANSYS Inc., Houston, USA). An axial load of 30 kgf was applied and the values of main maximum stress and microstrains were analyzed. For in vitro analysis, blocks identical to those created previously were made, seven strain-gauges were placed on the surface of the block, four tangential to each of the implants and three transverse to the implants. Plastic copings were adapted to a wax pattern and then cast. The metallic superstructure was screwed with a torque of 10 N.cm. For load application, a load application device (DAC) with a load of 30 kgf was used, for 10 seconds. Data were submitted to ANOVA and Tukey tests (p <0.05). Statistical difference was observed for "Implant angulation" factors (P = 0.000) and "Load application point" factor (P = 0.000). The data obtained by the finite element analysis were presented as: qualitative results of stress that were analyzed following the color scheme of the scale and results of deformation values, presented in graphs, where it observed a higher concentration of tension in the inclined implants in 30° at the ... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
209

Análise in vivo da modulação óssea em implantes de titânio com superfície em nanoescala /

Carvalho, Lais Morandini. January 2017 (has links)
Orientador: Luana Marotta Reis de Vasconcellos / Coorientador: Gustavo Mendonça / Banca: Daniela Baccelli Silveira Mendonça / Banca: Elisa Mattias Sartori / Banca: Yasmin Rodarte Carvalho / Banca: Renata Falchete do Prado / Resumo: Nas últimas décadas houve um aumento considerável na utilização dos implantes metálicos para aplicações na área da ortopedia e odontologia, por isso as pesquisas têm como foco estudar os mecanismos biológicos de interação osso-implante. A nanotopografia de superfície de implantes osseointegráveis apresenta efeito direto sobre a resposta biológica óssea. No entanto a maneira como afeta a osseointegração in vivo ainda não está totalmente elucidada. O objetivo neste estudo foi comparar in vivo a influência da superfície em nanoescala (nano) confeccionada em implantes de titânio comercialmente puro (Ticp), comparado-a a superfície lisa (controle) em modelo experimental de camundongos osterix-mcherry (Osx-mcherry), os quais expressam proteína fluorescente concomitante com a expressão do gene osterix (Osx). Os animais receberam implantes de superfície lisa no fêmur direito e com nanoescala no fêmur esquerdo. Após diferentes períodos de eutanásia baseados na metodologia empregada foram realizados nas peças e nas células os seguintes testes biológicos: microscopia eletrônica de varredura (MEV) para avaliação da adesão celular e da superfície do implante; histologia e nanotomografia (nanoCT) para observação e quantificação de osso neoformado na interface osso/implante; citometria de fluxo para quantificação de células marcadas pelo gene osterix; PCR em tempo real (qPCR) para avaliação da expressão gênica; coloração fosfatase ácida resistente ao tartarato (TRAP) para contagem de osteoc... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last decades there has been a considerable increase in the use of metal implants for applications in the area of orthopedics and dentistry, so the researches are focused on studying the biological mechanisms of boneimplant interaction. Surface nanotopography of osseointegrated implants has a direct effect on the biological response of bone. However the way it affects osseointegration in vivo is not yet fully elucidated. The aim of this study was to compare the in vivo influence of the nanoscale surface (nano) made on implants of commercially pure titanium (Ticp) with the smooth surface (control), using an experimental model of osterix-mcherry mice (Osxmcherry), which express fluorescent protein concomitant with osterix gene expression (Osx). The animals received implants with smooth surface in the right femur and nanoscale in the left femur. After different periods of euthanasia based on the methodology used, biological tests were performed in the femur and cells: scanning electron microscopy (SEM) for evaluation of cell adhesion and implant surface; histology and nanotomography (NanoCT) for observation and quantification of neoformed bone at implant interface; flow cytometry for quantification of cells marked by the osterix gene; Realtime PCR (qRT-PCR) for gene expression evaluation; tartrate resistant acid phosphatase staining (TRAP) for osteoclast counts. Our results showed that most genes studied were overexpressed in the nanoscale surface and some of which presented statistical differences(t Test, p <0.05), such as: Osx (osterix), Alp (alkaline phosphatase), Prx1 (related paired homeobox), Dmp1 (Dolicol-phosphatase mannosyltransferase subunit 1), Bsp (bone sialoprotein) and Ocn (osteocalcin). The two-way ANOVA statistical test followed by the Tukey test when necessary were used for the other experiments and the level ...(Resumo completo, clicar acesso eletrônico abaixo) / Doutor
210

Comportamento eletroquímico do Ti2, Ti4, Ti4hard e Ti6Al4V em função de diferentes aplicações tópicas de flúor /

Zanna, Carolina Ferrairo Danieletto. January 2017 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Leonardo Perez Faverani / Banca: Valentim Adelino Ricardo Barão / Resumo: Pacientes com reabilitações implantossuportadas parciais podem apresentar condições clínicas que necessitem de fluorterapia. Sabe-se que o fluoreto possui uma ação corrosiva em alguns metais, portanto o objetivo deste estudo foi investigar o comportamento eletroquímico e as alterações de superfície, dos titânios Grau 2 (comercialmente puro Grau 2 - Ti2), Grau 4 - Ti4, Grau 4 hard - Ti4h, e Grau 5 - Ti5, comumente utilizados para confecção de implantes e componentes protéticos, frente a exposição de aplicações tópicas de flúor em bochecho e gel. Espécimes cilíndricos (3mm de altura e 8mm de diâmetro) (n=20) foram confeccionados a partir de cada titânio e submetidos a metalografia. A amostra foi dividida em quatro grupos: Baseline (n=20), Controle - C (n=20), Bochecho - B (n=20) e Gel - G (n=20). No Baseline os espécimes foram caracterizados através de microdureza de Vickers, rugosidade superficial - Ra, Microscopia Eletrônica de Varredura - MEV e Espectroscopia de Energia Dispersiva - EED. No Bochecho, os espécimes ficaram imersos em saliva artificial pura (SA) acrescida de NaF (225ppm F-) e mantidos em constante agitação durante 30horas e 41minutos, simulando bochechos diários; no Gel, os espécimes foram imersos em SA acrescida de NaF (12.300ppm F-), mantidos por 1 minuto, na sequência, transferidos para solução de SA pura, na qual permaneceram por 30 minutos (processo repetido 6 vezes), simulando aplicações de flúor fosfato acidulado 1,23% e no Controle, os espécimes não ent... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Patients with partial implant-supported rehabilitations may present clinical conditions that require fluorotherapy. It is known that fluoride has a corrosive action on some metals, so the objective of this study was to investigate the electrochemical behavior and surface changes of grade 2 titanium (commercially pure Grade 2 - Ti2), Grade 4 - Ti4, Grade 4 Hard - Ti4h, and Grade 5 - Ti5, commonly used for the preparation of implants and prosthetic components, against the exposure of topical applications of fluoride in mouthwash and gel. Cylindrical specimens (3mm high and 8mm diameter) (n = 20) were made from each titanium and subjected to metallography. The sample was divided into four groups: Baseline (n = 20), Control - C (n = 20), Bochecho - B (n = 20) and Gel - G (n = 20). In the Baseline the specimens were characterized by Vickers microhardness, surface roughness - Ra, Scanning Electron Microscopy - SEM and Dispersive Energy Spectroscopy - EED. In Bochecho, the specimens were immersed in pure artificial saliva (SA) plus NaF (225ppm F-) and kept in constant agitation for 30hours and 41minutes, simulating daily mouthwashes; In the Gel, the specimens were immersed in SA plus NaF (12,300ppm F-), maintained for 1 minute, then transferred to pure SA solution, in which they remained for 30 minutes (6 times repeated procedure), simulating Fluorinated phosphate 1.23% and in Control, the specimens did not come into contact with fluoride solutions. The groups C, B and G were submit... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0728 seconds