• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 115
  • 44
  • 3
  • 2
  • Tagged with
  • 164
  • 164
  • 73
  • 60
  • 57
  • 55
  • 55
  • 49
  • 37
  • 33
  • 29
  • 25
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Avaliação da deformação gerada nos componentes intermediários de prótese fixa implanto-suportada com diferentes alturas, com a utilização de extensômetros lineares elétricos / Assessment of the deformation of the generated in different heights of abutments of mandibular implant-supported prosthesis, with the use of strain Gauges

Valdey Suedam 10 June 2005 (has links)
Em prótese total fixa implanto-suportada as diferentes alturas dos intermediários traduzem-se em diferentes braços de alavanca aos quais os implantes são submetidos levando a um efeito de deformação dos componentes que até o momento é desconhecido. O objetivo deste trabalho foi verificar a deformação gerada em diferentes alturas de componentes intermediários de prótese total fixa mandibular implanto-suportada. Para isto foi utilizado um modelo mestre de forma circular confeccionado em aço comum (Aço 1010/20) com cinco perfurações onde foram adaptadas as réplicas de fixação de 3,75mm de diâmetro, nas quais foram fixados os intermediários. O trabalho apresentou dois grupos de três corpos de prova cada, divididos de acordo com o tipo de liga das infra-estruturas(CoCr ou PdAg) e altura dos intermediários (4,0 mm, 5,5 mm e 7,0 mm), respectivamente. Foi aplicada uma força de 100N, em um ponto de referência pré-determinado na extremidade livre, a uma distância de 15mm do centro da réplica de fixação terminal e realizadas leituras das deformações geradas na mesial e na distal de cada intermediário, com o uso de extensômetros lineares elétricos. Os resultados do estudo demonstraram que o aumento da deformação captada no intermediário adjacente ao cantilever é promovido pelo aumento da altura dos intermediários e também pela utilização de uma liga de alto módulo de elasticidade. / In implant-supported prosthesis the different heights of abutments represent different lever arms to which the implants are submitted, leading to a deformation of the components that is not completely understood. The objective of this study was to assess the deformation ocurring in different heights of abutments of mandibular implant-supported fixed prosthesis. A circular master cast made of steel (Steel 1010/20) was used with five perforations containing implant replicas of 3,75mm of diameter in which the abutments were seated. The specimens were divided in two groups of three specimens each, according to the type of alloy of the framework (CoCr or PdAg) and the abutment's height (4,0 mm, 5,5 mm and 7,0 mm), respectively. A force of 100N was applied at a point 15mm distal to the center of the terminal abutment. Readings of the deformations generated on the mesial and distal aspects of the abutment were obtained with the use of strain gauges. The results of this study demonstrated that the deformation observed in the abutments adjacent to the cantilever arm is proportional to the increase of the abutment's height and elastic modulous of the alloy.
92

Efeitos do tratamento químico na descontaminação de superfícies de implantes metálicos: estudo microscópico em subcutâneos de ratos / Effects of chemical treatment of surfaces in decontamination of metallic implants: microscopic study in subcutaneous rats

Rafael Mansano de Castro Lara 09 March 2012 (has links)
O objetivo deste trabalho foi avaliar o efeito do tratamento químico com ácido cítrico, tetraciclina, EDTA e ácido fosfórico em discos de titânio de superfícies lisas e rugosas, após serem contaminados por biofilme bacteriano humano, e inseridos no tecido conjuntivo subcutâneo de ratos. Utilizou-se 180 discos de titânio, sendo 90 lisos e 90 rugosos, que foram colocados em 19 placas de acrílico utilizadas por voluntários durante 7 dias. Estes discos foram divididos em 12 grupos contendo 15 discos cada um: Grupo 1L: 15 discos lisos tratados com ácido cítrico; Grupo 1R: 15 discos rugosos tratados com ácido cítrico; Grupo 2L: 15 discos lisos tratados com tetraciclina ácida; Grupo 2R: 15 discos rugosos tratados com tetraciclina ácida; Grupo 3L: 15 discos lisos tratados com EDTA; Grupo 3R: 15 discos rugosos tratados com EDTA; Grupo 4L: 15 discos lisos tratados com ácido fosfórico; Grupo 4R: 15 discos rugosos tratados com ácido fosfórico; Grupo CL: 15 discos lisos que não receberam descontaminação (controle positivo liso); Grupo CR: 15 discos rugosos que não receberam descontaminação (controle positivo rugoso); Grupo EL: 15 discos lisos que não foram contaminados (controle negativo liso) e Grupo ER: 15 discos rugosos que não foram contaminados (controle negativo rugoso). Estes discos foram implantados no subcutâneo de ratos, os quais foram sacrificados após 7, 28 ou 84 dias. Foi realizada a avaliação microscópica descritiva e quantitativa do tecido conjuntivo formado nestes ratos. Foram avaliadas as médias das espessuras das cápsulas, a densidade de fibroblastos e de neutrófilos nos 3 períodos de tempo. Os resultados mostraram diferença na densidade de neutrófilos principalmente aos 7 dias e o ácido fosfórico mostrou os melhores resultados neste período, e ao final de 84 dias todos os tratamentos apresentaram resultados similares inclusive com relação ao grupo controle contaminado. Com relação à rugosidade os discos de superfícies lisas, apresentaram menor média na espessura da cápsula comparandose com os discos de superfícies rugosas, talvez demonstrando um aspecto de maior biocompatibilidade da superfície lisa após receber o tratamento de descontaminação, o que sugeriria maior efetividade na descontaminação dos protótipos lisos. / The purpose of this investigation was to evaluate the effects of treatment with citric acid, tetracycline, EDTA and phosphoric acid in titanium disks in smooth and roughened surfaces contaminated by bacterial biofilms in the connective tissue of rats. One hundred eighty titanium disks were used; 90 smooth surfaces and 90 roughened titanium surfaces, which were placed in 19 acrylic plates that were used by volunteers for 7 days. These disks were divided into 12 groups containing 15 disks each; Group 1L: 15 smooth disks were treated with citric acid; Group 1R: 15 roughened disks were treated with citric acid; Group 2L: 15 smooth disks were treated with tetracycline acid; Group 2R: 15 roughened disks were treated with tetracycline rough acid; Group 3L: 15 smooth disks were treated with EDTA; Group 3R: 15 roughened disks were treated with EDTA; Group 4L: 15 smooth disks were treated with phosphoric acid; Group 4R: 15 roughened disks were treated with phosphoric acid; Group CL: 15 smooth disks received no econtamination (smooth positive control); CR: 15 roughened disks did not receive decontamination (roughened positive control); EL: 15 smooth disks were not infected (smooth negative control) and ER: 15 roughened disks were not infected (roughened negative control). These disks were implanted subcutaneously in rats that were sacrificed after 7, 28 or 84 days. A descriptive and quantitative microscopic evaluation was performed. The average thickness of the capsules and the density of fibroblasts and neutrophils in three time periods were evaluated. The results showed differences in the density of neutrophilis mainly at 7 days and phosphoric acid showed the best results in this period, and at the end of 84 days, all treatments showed similar results even with the control group infected. In relation to the roughness, the smooth disks had a lower average capsule thickness compared with roughened disks, perhaps demonstrating an aspect of greater biocompatibility smooth surface, which would suggest greater effectiveness in decontamination of smooth disks.
93

Evolução dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial: revisão sistemática / Evolution of retention, fixation and anchorage extraoral in maxillofacial rehabilitation systems: a systematic review

Marcus Vinicius Cobein 02 July 2014 (has links)
Introdução: A utilização de próteses bucomaxilofaciais é de extrema importância para a reintegração no convívio social dos pacientes acometidos de deformidades congênitas ou adquiridas. Tendo em vista os avanços dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial realizou-se revisão sistemática. Objetivos: verificar a evolução das retenções das próteses bucomaxilofaciais comparando os sistemas osseointegrados, aos sistemas não osseointegrados, analisando algumas variáveis como: taxa de sobrevivência dos implantes ao longo do tempo, idade média dos pacientes, etiologia do defeito facial e sitio dos sistemas de retenção relacionado ao tipo de prótese, em formato de revisão sistemática. Métodos: Realizou-se busca bibliográfica nas bases de dados PubMed e SCOPUS, após elaboração de estratégias de busca, obteve-se 2630 artigos onde foram analisados títulos, resumos e eliminadas duplicidades. Resultados: Obteve-se 25 artigos pré-selecionados que passaram pelos critérios de inclusão e exclusão sendo eleitos 13 artigos para a revisão sistemática. Conclusão: As próteses retidas por implantes superam os sistemas convencionais. A perda dos implantes foi muito pequena nos estudos analisados, apesar do tempo de acompanhamento ser relativamente curto e dos protocolos distintos de tratamento. A idade adulta entre a quarta e quinta década de vida foi a de maior prevalência. A etiologia mais incidente são as neoplasias. Os sistemas osseointegrados fixados por implantes por retenção barra clipe se localizam mais na região auricular e retenção magnética nas regiões nasal e orbital. Os sistemas não osseointegrados, a retenção anatômica é mais utilizada na região ocular, retenção mecânica na região orbital e o uso da retenção por adesivos nas regiões nasal e orbital. / Introduction: The use of maxillofacial prostheses is the most importance for reintegration into social life of patients suffering from congenital or acquired deformities. Given the advances in retention, fixation and extraoral anchorage systems in maxillofacial rehabilitation got systematic review. Objectives: To observe the evolution of the retentions of maxillofacial prostheses comparing osseointegrated systems, non osseointegrated systems, analyzing some variables such as survival rate of implants over time, mean patient age, etiology of facial defect and place restraint systems related kind of prosthesis, in a systematic review format. Methods: We performed a literature search in PubMed and SCOPUS database, after preparation of search strategies, we obtained 2630 articles where were checking titles, abstracts and eliminated duplicates were analyzed. Results: We obtained 25 pre-selected articles that passed the criteria for inclusion and exclusion being elected 13 articles for systematic review. Conclusion: The dentures retained by implants outperform conventional systems. The loss of the implants was very small in the analyzed studies, although the follow-up time is relatively short and the different treatment protocols. Between the fourth and fifth ages of life was the most prevalent. The most frequent etiology are neoplasms. Osseointegrated systems for fixed for implants retention bar clip are located more auricular and magnetic retention in the regions nasal and orbital. Non osseointegrated systems, anatomical retention is most commonly used in the ocular region, mechanical retention in orbital region and the use of adhesives for retention in the regions nasal and orbital.
94

Efeito do parafuso cônico na simulação da mastigação sobre a interface implante/pilar em diferentes relações coroa/implante / Effect of the conical head screw in the mechanical loading on implant/abutment interface in different crown/implant ratio

Isabela Rodrigues Teixeira da Silva 17 May 2016 (has links)
Este estudo tem como objetivo avaliar 2 diferentes desenhos de parafusos de pilares, o parafuso de cabeça quadrada (PCQ) e o parafuso de cabeça cônica (PCC), verificando se em diferentes relações coroa/implante (RCI) haverá mudança no contra-torque após a ciclagem mecânica. Inicialmente a área superficial do PCQ e do PCC foi mensurada através da análise digital das imagens dos parafusos no software de projeto 3D SolidWorks. Foram utilizados 40 conjuntos Implante/Parafuso/Pilar, os conjuntos foram divididos em 4 grupos: GRUPO A: 10 conjuntos com pilares medindo 9,8mm de altura, simulando uma RCI>1, fixados com PCQ; GRUPO B: 10 conjuntos com pilares medindo 6,0mm de altura, simulando uma RCI<1, fixados com PCQ; GRUPO C: 10 conjuntos com pilares medindo 9,8mm de altura, simulando uma RCI>1, fixados com PCC e GRUPO D: 10 conjuntos com pilares medindo 6,0mm de altura, simulando uma RCI<1, fixados com PCC. Os 40 conjuntos foram fixados em resina acrílica a uma angulação de 30º em relação ao longo eixo. Os pilares foram fixados aos implantes aplicando um torque de aperto de 35Ncm. Os conjuntos foram posicionados na máquina de ensaios de simulação de mastigação que opera com cargas de 100Ncm e cada grupo foi ciclado até atingir 1.0x106 ciclos. Os contra-torques dos parafusos foram aferidos em torquímetro digital para todos os grupos em 2 momentos (pré-ciclagem mecânica e pós-ciclagem mecânica). Para analisar os resultados a metodologia estatística de ANOVA (nível de significância de p <= 0,05) foi utilizada, seguida de comparações múltiplas de Tukey. Na mensuração da área superficial dos parafusos verificou-se que o PCC apresenta maior área de contato entre a interface pilar/parafuso (4,16 mm²) do que o PCQ (1,76 mm²). Avaliando os fatores testados e os p-valores observou-se que o PCQ é diferente estatisticamente do PCC (p-valor <0,0001), independente do momento de avaliação, sendo que a porcentagem de contra-torque é maior para PCC (90,6%) do que para PCQ (80,9%); a RCI>1 não difere estatisticamente da RCI<1 (p-valor 0,1203), apesar da porcentagem de contra-torque ser menor para RCI>1 (84,6%) do que para RCI<1 (86,8%) e o momento pré-ciclagem mecânica diferente estatisticamente do momento pós-ciclagem mecânica (p-valor <0,0001), sendo que na pré-ciclagem a média de porcentagem do contra-torque é maior (92,5%) do que na pós-ciclagem (78,9%). Baseado nos resultados e dentro das limitações do presente estudo, podemos concluir que o PCC apresenta desempenho superior ao PCQ, no que se diz respeito a afrouxamento, o que caracteriza o PCC como uma possibilidade de melhoria em sistemas de implantes de conexão hexagonal externa. Foi possível concluir também que o desenho cônico do PCC influencia no contra-torque após a ciclagem mecânica, sendo indicado sobretudo em uma situação de RCI>1, onde o parafuso é mais requisitado. / The aims of this study is to evaluate two different abutment screws designs, a flat head screw (FHS) and a conical head screw (CHS), making sure if different crown/implant ratio (CIR) result changes in the removal torque after mechanical cycling. Initially, the surface area of the FHS and a CHS was measured by digital image analysis of the screws in 3D SolidWorks Software. Forty sets implant/screw/abutment were used, the sets were divided into 4 groups: GROUP A: 10 sets with abutments 9,8mm height, simulating a CIR>1, fixed with FHS; GROUP B: 10 sets with abutments 6,0mm height, simulating a CIR<1, fixed with FHS; GROUP C: 10 sets with abutments 9,8mm height, simulating a CIR>1, fixed with CHS and GROUP D: 10 sets with abutments 6,0mm height, simulating a CIR<1, fixed with CHS. The sets were fixed in acrylic resin angled 30 ° to the long axis. The abutments were fixed to the implants by applying a torque of 35Ncm. The sets were mechanically loaded. The peak load was 100Ncm vertical force and each group was performed for 1,0x106 cycles. The preload and the postload reverse toque was measured with the digital torque meter and recorded. To analyze the results the methodology of ANOVA (significance level of p <= 0, 05) was used followed by Tukey multiple comparisons. In measuring the surface area of the screws, we found that CHS has greater contact area in the abutment/screw interface (4,16mm²) compared to FHS (1,76mm²). Evaluating the factors tested and p-values we have statistically difference between FHS and CHS (p- value < 0,0001), regardless the time of evaluation, the percentage of CHS reverse torque (90,6 %) is higher than FHS reverse torque (80,9%); CIR>1 and CIR<1 does not differ statistically (p-value 0,1203), although the percentage of reverse torque CIR>1 (84,6 %) is smaller than the percentage of reverse torque CIR<1 (86,8%) and the mechanical preload time differ statistically mechanical postloading time (p-value<0,0001 ), whereas the reversal torque in preload time (92,5%) is largest than reversal torque in postloading time (78,9 %). Based on the results and within the limitations of this study, we can conclude that the CHS outperform the FHS, as regards loosening, which features the CHS as a possible improvement in external-hex implants connections. It was also possible to conclude that the CHS design influences the reverse torque after the mechanical loading, being particularly suitable in a situation CIR>1, where the screw is most required.
95

Avaliação do comportamento clinico e radiografico do cimento de fosfato de calcio como material de preenchimento em cirurgia de elevação do assoalho seio maxilar / Evaluation of clinical and radiographic of the calcium phosphate cement as fulfilling material in sinus lift surery

Sverzut, Alexander Tadeu, 1975- 07 February 2008 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T21:39:41Z (GMT). No. of bitstreams: 1 Sverzut_AlexanderTadeu_D.pdf: 3638330 bytes, checksum: 2872619a12beea0b990ef76ba0cc731a (MD5) Previous issue date: 2008 / Resumo: A instalação de implantes na região posterior da maxila várias vezes é confrontada com processos alveolares reabsorvidos, resultantes de uma combinação da pneumatização do seio maxilar, dos efeitos da doença periodontal, e do processo de reabsorção óssea fisiológica resultante da falta de estímulo funcional que sucede as exodontias. A elevação do assoalho do seio maxilar vem sendo praticada desde 1980 com o objetivo de aumentar a altura óssea nessa região para uma reabilitação protética suportada por implantes, e para tal vem sendo utilizados vários materiais de preenchimento. O presente estudo teve como objetivo avaliar clinica e radiograficamente o comportamento do Cimento de Fosfato de Cálcio (CFC) utilizado como material de preenchimento em cirurgias de elevação de seio maxilar. Foram operados 10 pacientes não-fumantes e sem alterações sistêmicas, que necessitavam de enxerto em seio maxilar para futura colocação de implantes osseointegráveis. Após um período que variou de 9 a 16 meses, foi realizada avaliação clínica da área enxertada e biópsia com broca trefina de 2mm de diâmetro, em região adjacente ao eixo do implante a ser inserido. Clinicamente, pôde-se observar que não houve reabsorção/substituição do material por osso, o material ainda encontrava-se presente e bem compacto, porém com extremamente friável. Foi possível na macroscopia visualizar no espécime o osso nascente e sua interface com o material. Apesar de nenhum paciente ter tido complicações pós-operatórias e o material ter apresentado características totalmente biocompatíveis, não foi possível a colocação de nenhum implante nos sítios com o material, devido a não formação óssea e sua facilidade em sofrer friabilidade. Foi possível concluir que o cimento de fosfato de cálcio não promove neoformação ósseas quando utilizado como material de preenchimento para elevações de assoalho de seio maxilar visando à reabilitação com implantes dentários e que a radiografia panorâmica não é um método confiável para avaliar o possível ganho ósseo com o emprego do biomaterial. / Abstract: Implant placement in the posterior maxilla is frequently challenged by resorbed alveolar processes due to a combination of maxillary sinus pneumatization, the effects of periodontal disease and the physiological bone resorption following tooth extractions. The sinus floor augmentation surgery has been performed since 1980 with the purpose of increasing bone height in this region, allowing implant-supported prosthetic rehabilitation. In the literature a various materials are used for fulfilling in the maxillary sinus litf. The present study aimed evaluate radiography and clinically the calcium phosphate cement (CFC) used as material of fulfilling in sinus lift surgery. Ten non-smoking and systemically healthy patients who needed maxillary sinus grafting for the placement of dental implants were operated. In a second surgical intervention, After a period that various of 9 the 16 months, the implant placement was preceded by clinical evaluation and biopsy of the lateral sinus wall using with a 2 mm diameter trefine bur, in the region of the bone wall created in the sinus lift procedure. Clinically, it could be observed that substitution/resorbable of the material for bone did not have, the material still met present and well compact. It was possible to visualize clearly in the specimen the native bone and its interface with the material. Although no patient to have had postoperative complications and the material to have presented biocompatible characteristics, was not possible the placement of the dental implants, which had not the new bone formation. According the methodology applied was possible to conclude that the calcium phosphate cement does not promote new bone formation when used as material of fulfilling sinus lift surgeries aiming the placement of dental implant rehabilitation and that the panoramic x-ray is not a greatest method to evaluate the possible osseous grow with the biomaterial. / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
96

Trabecular Adaptation to Continuously Loaded Endosseous Implants

Bailey, Grant S. January 1993 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Several studies have shown endosseous implants placed in areas of thick cortical bone to be an effective means of anchorage in complex orthodontic cases. The purpose of this study was to examine the viability of endosseous implants as orthodontic/orthopedic anchorage when placed in this cancellous bone. Eighteen 6-month-old male rabbits were used and stratified into three groups of six animals. Two implants placed (bilaterally) in the dorsal surface of the nasal bones. After a 12-week healing period, the control group (C) had a passive spring placed between the implants, and the 1 Newton constant group (1 NC) received a spring that delivered a constant compressive load of 1N. A 1N load was applied to the progressive load group (3NP) and sequentially increased to 3N over the course of the study. Bone labels were administered throughout the experiment at designated time intervals to provide quantification of the physiologic activity. Following histologic processing, analyses were conducted on midfrontal sections using microradiography and fluorescent microscopy. The implants were divided into three regions: supraflange, coronal, and apical. Within each region the percent woven and lamellar bone was recorded as well as the percent bone in contact with or near the implant surface. Remodeling activity was observed by using fluorescent bone labels. In the sections analyzed using fluorescent microscopy, the regions were further subdivided into zones. Using the bone label data, bone was categorized as old bone, new woven bone, new lamellar bone and marrow space. Within animal, paired t tests revealed no significant difference between right/left implants. Data was pooled and an ANOVA run to test for difference between groups. Few significant differences were seen. Student Newman-Keuls sequential range tests were used to test between region and zone. The coronal region showed trends of more bone overall in the 1NC and the 3NP load groups p < 0.10. The apical region had less bone overall. The fluorescent data showed few significant differences between groups; however, the coronal region showed trends of more bone overall. A RAP effect was observed in the zonal analysis for new lamellar bone. Sutural remodeling was observed at the cortical plate over the nasal suture. A significant trabecular response was not seen in this study; however, the implants in the experimental groups remained stable throughout the study possibly due to the implant design. It was concluded that implants placed in thin cancellous bones are suitable for use as orthodontic/orthopedic anchorage.
97

Avaliação da plataforma tri-channel por meio de microtomografia computadorizada e suas propriedades mecânicas após torque de inserção, fadiga e fratura / Tri-channel platform evaluation by computerized microtomography and its mechanical properties after insertion torque, fatigue and fracture

Morais, Renata Costa de 26 October 2018 (has links)
Para avaliação das propriedades físico-mecânicas de implantes tri-channel Dérig, quanto ao efeito de acréscimo de 0,25mm no corpo do implante 3.5 NP (em relação ao controle 3.5 NP) e à influência da plataforma switching (em diâmetros iguais de 4,3 mm e plataformas distintas - NP e RP), o presente estudo relacionou resistência ao torque de inserção (avaliação do microgap entre implante/pilar protético - mensurações bi e tridimensionais), em microtomografia computadorizada (CT); resistência à fratura e resistência à fadiga. Para a resistência ao torque de inserção, os implantes foram divididos, aleatoriamente, em quatro subgrupos (n=10), segundo torque: GT45: 45 N.cm; GT80: 80 N.cm; GT120: 120 N.cm; GT150: 150 N.cm. Os conjuntos implante/pilar/parafuso foram levados às análises de deformação bi e tridimensional em CT. Para o teste de resistência à fratura, os conjuntos implantes/munhões foram levados à máquina de ensaios universais, até a falha e, posteriormente, às microscopias óptica e eletrônica de varredura. Para a resistência à fadiga, os conjuntos (n=12) foram submetidos a ensaio cíclico (5 Hz, 5° - 55° C, cargas em 80, 120, 160, 200, 240, 280 e 320 N, máximo de 2x104 ciclos) e carregados até a falha (ou máximo de 14x104 ciclos) (análise de sobrevivência Life Table Survival Analysis). Para o envelhecimento mecânico, os conjuntos (n=12) foram submetidos a 106 ciclos (2 Hz, 120 N, 5º - 55º C) e, novamente, levados às análises microscópicas. Após a análise estatística (2-way ANOVA, Bonferroni, p<0,05), para a análise da porcentagem de deformação bi e tridimensional dos torques de inserção em CT, há diferenças significantes (p<0,05) em todas as comparações, à exceção de 4.3 NP x 4.3 RP (45N). As microtomografias evidenciaram microgaps em conjuntos novos e aumento, qualitativo, dos mesmos, em diâmetros e plataformas menores. A comparação linear com conjuntos novos demonstrou diferenças significantes (p<0,05) em 3.5 NP e 3.75 NP (todos os torques) e 4.3 NP (120 e 150 N.cm). Para o ensaio de resistência à fratura (1-way ANOVA, Tukey B, p<0,05), 4.3 NP apresentou força máxima de deformação maior (p<0,05) que 3.75 NP e 3.5 NP (p=0,004), mas não houve diferença significante entre 4.3 RP, 3.5 NP e 3.75 NP (p>0,05). Quanto aos ensaios de resistência à fadiga, o envelhecimento mecânico levou ao afrouxamento dos parafusos de todos os grupos analisados, sendo que, à exceção de 3.75 NP, houve diferenças significativas (p<0,05) entre perdas de torques inicial e final; para a fadiga acelerada, ambos os grupos de 4,3 mm (NP e RP) sobreviveram ao final do ensaio, sendo que houve fratura de todas as amostras de 3.5 NP. Finalmente, quanto à probabilidade de sobrevivência, houve diferença significante (p<0,05) entre 3.5 NP e 3.75 NP, com taxa de 92% para este último. Conclui-se que o diâmetro 4,3 mm é mais resistente que 3,5 mm; 4.3 NP apresentou maior resistência à fratura; o envelhecimento mecânico leva à perda de torque; a fadiga mecânica acelerada tem influência em diâmetros menores e a metodologia em CT é válida para análises bi e tridimensional / To investigate the physical-mechanical properties of Dérigs tri-channel implants, regarding the 0.25 mm addition in 3.75 NP implant structure (in relation to 3.5 NP as control) and the influence of platform switching (in equal diameters of 4.3 mm and different platforms - Narrow and Regular), this study related the resistance to insertion torque (microgap evaluation between implant and abutment - bi and tridimensional measurements), computerized microtomography (CT); resistance to fracture and fatigue. For the resistance to insertion torque, the samples were randomly divided into four subgroups (n=10), according to the torque applied: GT45: 45 N.cm; GT80: 80 N.cm; GT120: 120 N.cm; GT150: 150 N.cm. The implant/abutment/screw assemblies were taken to bi and tridimensional deformation analyzes in CT. For the fracture strength test, the implant/abutment assemblies were taken to the universal test machine until failure and then to optical and scanning electron microscopes. For the fracture resistance, the sets (n=12) were subjected to a cyclic test (5 Hz, 5° - 55° C, loads in 80, 120, 160, 200, 240, 280 and 320 N, maximum of 2x104 cycles) and loaded to failure (or maximum of 14x104 cycles) (Life Table Survival Analysis). For mechanical aging, the sets (n=12) were submitted to 106 cycles (2 Hz, 120 N, 5º - 55º C) and, again, to microscopic analysis. After statistical analysis (2-way ANOVA, Bonferroni, p<0.05), there were statistical differences (p<0.05) in all comparisons for the bi and three-dimensional deformation percentages of the insertion torques in CT, except between 4.3 NP x 4.3 RP (45N). The microtomographies evidenced microgaps in new sets and a qualitative increase of the same sets in diameters and smaller platforms. The linear comparison with new sets showed significant differences (p<0.05) in 3.5 NP and 3.75 NP (all torques) and 4.3 NP (120 and 150 N.cm). As for the fracture resistance test (1-way ANOVA, Tukey B, p<0.05), 4.3NP had a higher maximum deformation force (p<0.05) than 3.75 NP and 3.5NP (p=0.004), but there was no significant differences between 4.3 RP, 3.5 NP and 3.75 NP (p>0.05). Regarding the fatigue strength tests, the mechanical aging led to the screw loosening of all groups analyzed, and by the exception of 3.75 NP, there were significant differences (p<0.05) between initial and final torque applied; for the accelerated fatigue, both groups of 4.3 mm (NP and RP) survived at the end of the test, with fractures in all 3.5 NP samples. Finally, regarding the survival rate, there was a significant difference (p<0.05) between 3.5 NP and 3.75 NP, with a 92% rate for this last one. It could be concluded that the diameter 4.3 mm is stronger than 3.5 mm; 4.3 NP presented higher fracture resistance; the mechanical aging leads to screw loosening; the accelerated mechanical fatigue has influence in smaller diameters and the methodology in CT is valid for bi and three-dimensional analyzes
98

Descontaminação da superfície de implantes dentários por meio da terapia fotodinâmica / Decontamination of dental implants surfaces by photodynamic therapy

Marotti, Juliana 19 January 2009 (has links)
As lesões da periimplantite se não tratadas propriamente podem levar à reabsorção óssea e conseqüente perda do implante. Os implantes com superfície rugosa apresentam melhor resposta do tecido ósseo e melhor ancoragem, entretanto facilitam a formação de biofilme sobre sua superfície, dificultando o tratamento da periimplantite. Diversos métodos de limpeza da superfície do implante têm sido descritos, porém podem danificar sua superfície ou gerar resistência a longo prazo. A terapia fotodinâmica (PDT) surge como uma opção viável e de baixo custo para o tratamento da periimplantite. O objetivo deste estudo in vitro foi analisar a descontaminação bacteriana da superfície de implantes por meio da terapia fotodinâmica. 60 implantes dentários (TiUnite Nobel) foram igualmente divididos (n=10) em 4 grupos e 2 subgrupos. Em G1 não houve descontaminação (controle negativo), enquanto em G2 realizou-se a descontaminação pelo método tradicional com gluconato de clorexidina a 0,12% (controle positivo). G3 (PDT laser+corante) e G4 (sem corante) foram divididos em dois subgrupos cada, sendo que em G3a e G4a utilizou-se a PDT por 3 minutos, G3b e G4b por 5 minutos. Após 5 minutos em contato com o corante azul de metileno a 0,01% (G3), os implantes foram irradiados (G3 e G4) com laser diodo de baixa potência (AsGaAl, 660 nm, 30 mW) por 3 ou 5 minutos (7,2 e 12 J). Após diluições seriadas, os meios de cultura foram mantidos em atmosfera de anaerobiose por uma semana, e então realizada a contagem das unidades formadoras de colônias para cada grupo. Os testes estatísticos de Kruskal-Wallis e Mann-Whitney mostraram haver diferença significante (p<0,001) entre G1 e os demais grupos, bem como G4 comparado com G2 e G3. Melhores resultados de descontaminação foram obtidos para G2 e G3, sem diferença estatisticamente significante entre si. Os resultados obtidos neste estudo sugerem que a terapia fotodinâmica pode ser considerada um método eficaz para redução bacteriana em superfícies de implantes e que somente a irradiação laser, sem a associação do corante, foi menos eficiente (p<0,001) que a PDT. / If periimplantitis lesions are not properly treated, they can lead to bone resorption and loss of the implant. Implants with rough surface present better results and anchorage, however, they can facilitate biofilm formation on their surface, making the treatment of periimplantitis more difficult. Several surface debridement methods have been reported, however, some of them can injury the implant surface or create bacterial resistance in a long term followup. The photodynamic therapy (PDT) is a viable and low-cost option for treatment of periimplantitis. The aim of this in vitro study was to analyze the decontamination of implant surfaces by means of photodynamic therapy. 60 dental implants (TiUnite Nobel) were equally distributed (n=10) into 4 groups and 2 subgroups. At G1 group there was no decontamination (negative control), while in G2 the decontamination was made through the conventional method with chlorhexidine gluconate 0.12% (positive control). G3 (PDT laser+dye) and G4 (without dye) were divided in two subgroups each; while in G3a and G4a PDT was carried out for 3 minutes, G3b and G4b, was for 5 minutes. After five minutes in contact with methylene blue 0,01% dye (G3), the implants were irradiated (G3 and G4) with a diode low-power laser (AsGaAl, 660 nm, 30 mW) for 3 or 5 minutes (7.2 and 12J). After the dilutions, the culture media were kept in anaerobiosis atmosphere for one week, and then the counting of bacteria colonies was done for each group. The statistical tests of Kruskal-Wallis and Mann-Whitney showed significant difference (p<0,001) between G1 and other groups, as well as G4 compared with G2 and G3. Better results of decontamination were obtained in G2 and G3, with no statistical significance between them. The results of this study suggest that the photodynamic therapy can be considered an efficient method of bacteria reduction of implants surfaces, and only the laser irradiation, without dye association, was less efficient (p<0,001) than PDT.
99

Estudo in vivo e in vitro da corrosão de ligas de Co-Cr e de Ni-Cr utilizadas em estruturas protéticas de implantes orais / In vitro and in vivo studies of corrosion of Co-Cr and Ni-Cr alloys used in oral implant prosthetic superstructures

Inada, Eduardo 13 August 2013 (has links)
Este trabalho avaliou o comportamento eletroquímico de três ligas de níquel-cromo e duas de cobalto-cromo in vitro e in vivo. Nos estudos in vitro foram fabricados eletrodos de trabalho a partir destas ligas. Estes eletrodos ficaram imersos em meio de NaCl 0,15 mol.L-1 a 36,5°C e foram submetidos às técnicas do potencial de circuito aberto, polarização potenciostática anódica e cronoamperometria. Para os estudos in vivo foram selecionados quinze pacientes com implantes já osseointegrados e aguardando a instalação das próteses. Esses pacientes foram distribuídos aleatoriamente em cinco grupos, correspondentes às cinco ligas diferentes. Deste modo, as estruturas protéticas dos implantes foram fundidas utilizando as cinco ligas. Foi utilizada a microscopia eletrônica de varredura (MEV) e a espectroscopia por dispersão de energia (EDS) como métodos de análise das superfícies linguais metálicas das próteses, antes da instalação em ambiente oral e após seis meses de permanência. Vistas por MEV, as ligas duas de cobalto-cromo Starloy C e Remanium 2001 e duas de níquel-cromo Wiron 99 e Remanium CSe apresentaram superfícies heterogêneas caracterizadas por uma fase semelhante à matriz da liga e a outra fase, composta por elementos de maior densidade atômica, correspondente à fase interdendrítica. Após seis meses, não houve sinais de corrosão e alterações significativas na composição destas ligas. As ligas de Co-Cr avaliadas, sob o ponto de vista eletroquímico, indicam comportamento catódico quando unidas ao implante sendo um fator indicativo de proteção à corrosão. Dentro dos limites dos estudos in vitro, as ligas de Ni-Cr apresentaram um filme passivo com ampla faixa de potencial em que se mantêm passiva e ausência de corrosão localizada. A liga de níquel-cromo Dan Ceramalloy apresentou a superfície heterogênea com quatro áreas distintas (área 1 rica em titânio; área 2 rica em níquel; área 3 correspondente à matriz; área 4 rica em molibdênio). Após seis meses, as três próteses metalo-cerâmicas apresentaram as regiões correspondentes à fase 2, rica em níquel, com depressões em baixo relevo, sugerindo a oxidação com a liberação de íons níquel. Nos estudos in vitro a liga Dan Ceramalloy apresenta potencial de corrosão mais negativo, uma faixa passiva de potencial mais estreita e um filme menos protetor, quando comparada com as demais ligas estudadas. Apesar de não ter sido observado clinicamente o processo de corrosão das ligas, os estudos in vitro e in vivo deste material, permitiram verificar o seu comportamento eletroquímico e sugerir a descontinuidade do seu emprego em estruturas protéticas de implantes orais. Os estudos in vitro e in vivo apresentaram concordância para todos os materiais estudados. / In this study, the electro-chemical behavior of three nickel-chrome and two cobalt chrome alloys was studied in vitro and in vivo. In the in vitro studies, working electrodes made of these alloys were fabricated. These electrodes were immersed in a medium of NaCl 0.15 mol.L-1 at 36.5°C and were submitted to the open circuit potential, anodic potentiostatic polarization and chronoamperometry techniques. For the in vivo studies, 15 patients whose implants had osseointegrated, and who were waiting for dental implant placement, were selected. These patients were randomly distributed into five groups, corresponding to the five different alloys. Thus the prosthetic implant superstructures were cast, using the five alloys. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used as methods to analyze the metal lingual surfaces of the prostheses, before they were placed in the oral environment, and after six months in place. Visualized by SEM, the two cobalt-chrome alloys Starloy C and Remanium 2001, and two types of nickel-chrome - Wiron 99 and Remanium Cse - presented heterogeneous surfaces characterized by a phase similar to that of the alloy matrix, and the other phase composed of elements of greater atomic density, corresponding to the interdendritic phase. After six months, there were no signs of corrosion and significant alterations in the composition of these alloys. The Co-Cr alloys evaluated, from an electrochemical point of view, indicated a cathodic behavior when united to the implant, this being a factor indicative of protection against corrosion. Within the limits of the in vitro studies, the Ni-Cr alloys presented a passive film with an ample range of potential in which they remained passive, with absence of corrosion due to pitting. The nickel-chrome alloy Dan Ceramalloy presented a heterogeneous surface with four distinct areas (Area 1 rich in titanium; Area 2 rich in nickel; Area 3 corresponding to the matrix; Area 4 rich in molybdenum). After six months, the three metal-ceramic dental prostheses presented the regions corresponding to Phase 2, rich in nickel, with depressions in low relief, suggesting oxidation with nickel ion release. In the in vitro studies, the alloy Dan Ceramalloy presented a more negative corrosion potential, a narrower range of passive potential and a less protective film, when compared with the other alloys studied. In despite of the process of corrosion of the alloys not having been clinically observed, the in vitro and in vivo studies of this material allowed verification of its electrochemical behavior, and suggest that its use in prosthetic superstructures for oral implants should be discontinued. The in vitro and in vivo studies were shown to be in agreement for all the materials studied.
100

Avaliação do destorque de dois tipos de parafusos fixadores do munhão e da resistência à tração de coroas cimentadas sobre munhões com diferentes características superficiais

Toledo, Fabiane Lopes 02 September 2011 (has links)
Problemas freqüentes na prótese sobre implante são o afrouxamento do parafuso que une o munhão ao implante e a soltura da prótese cimentada. Assim, foi estudada a manutenção da força de torque, promovida por 2 diferentes parafusos fixadores de munhão, e a resistência à remoção por tração de coroas de NiCr, cimentadas ou re-cimentadas com fosfato de zinco sobre munhões com diferentes características. Numa primeira fase, foram utilizados 20 conjuntos implante/munhão/parafuso (NEODENT), constituídos de liga de Ti, nos quais existiam 10 parafusos comuns e 10 revestidos com carbono (Neotorque). A força de torque de 32 N era aplicada com um torquímetro analógico de precisão (TOHNICHI) e, para a aplicação cíclica de carga de compressão axial, foi utilizada uma máquina eletro-mecânica de fadiga, com carga de 200 N e freqüência de 2 hertz, durante 500.000 ciclos. Na segunda fase, foram usados 30 conjuntos (implante/munhão/parafuso e respectivas coroas), onde existiam apenas parafusos comuns, porém com munhões de diferentes tamanhos e aspectos superficiais: o munhão universal (MU), o personalizado original (MPO) e o personalizado irradiado (MPI). As coroas destes 2 últimos grupos já haviam sido cimentadas e tracionadas, num trabalho anterior. Todas as coroas foram agora cimentadas com fosfato de zinco e submetidas (7 dias depois) a ensaios de tração, em uma máquina universal de ensaios regulada na velocidade de 0,5 mm/min. Nas condições deste trabalho, foi possível concluir que ambos os parafusos analisados (comum e Neotorque) apresentaram comportamento semelhante, na manutenção da força de torque promovida, e que a resistência à remoção por tração de coroas, cimentadas pela primeira vez, com o munhão universal (MU), foi a menor de todas (227,83 N.cm); para os caso das recimentações, com o munhão personalizado de textura original, esta resistência apresentou valor intermediário (448,37 N.cm), tendo sido a maior de todas (1.570,76 N.cm) aquela apresentada pelo munhão personalizado que sofreu irradiação por LASER. / Frequent problems in implant prosthodontics are loosening the screw that joins the abutment to implant and the releasing of the cemented prosthesis. Thus, it was studied both the torque force mantenaince promoted by two different screws as the resistance to removal by traction of NiCr crowns, cemented or re-cemented with zinc phosphate over abutments with different characteristics. In a first phase, it were used 20 Ti alloy-made sets (composed by Neodent implant / abutment / screw), in which there were 10 slotted screws carbon-coated (Neotorque). The torque force of 32 N was applied with an analogical torque wrench (TOHNICHI) and the cyclic axial compression load with a fatigue electro-mechanical machine, with a load of 200 N and frequency of 2 Hz, over 500,000 cycles. In the second phase, it was used 30 other sets (composed by implant / abutment / screw and their crowns) where there were only common screws, but with sleeves of different size and superficial aspects: the universal abutment (MU), that personalizable with original texture (MPO) and the personalizable with a LASER treatment (MPI). Crowns of these two latter groups had already been cemented and pulled in a previous work. All crowns were here cemented with zinc phosphate and submitted (7 days later) to tensile tests in an universal testing machine set at a speed of 0.5 mm / min. In the conditions of the present work, it was concluded that both analyzed screws (common and Neotorque) behaved similarly, maintaining the torque force promoted, and that resistance to removal by traction of crowns cemented by first time with the universal abutment (MU) was the lowest of all (227.83 N.cm); for recementations, personal abutment with original texture had intermediate values resistance (448.37 N.cm), being the largest of all (1570.76 N.cm) that presented by the abutment modified by LASER irradiation.

Page generated in 0.1318 seconds