• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 166
  • 1
  • Tagged with
  • 167
  • 167
  • 98
  • 89
  • 86
  • 78
  • 61
  • 52
  • 43
  • 40
  • 24
  • 23
  • 22
  • 22
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

POTENCIAL EROSIVO DE BEBIDAS INDUSTRIALIZADAS DE LARANJA SOBRE O ESMALTE DECÍDUO E CIMENTOS IONOMÉRICOS (IN VITRO) / Erosive potential of industrial orange beverage in deciduous enamel and glass ionomer cements (in vitro)

Gregol, Luísa Rech Gomes 28 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:23Z (GMT). No. of bitstreams: 1 Luisa Gregol.pdf: 2797827 bytes, checksum: 470916da6ea25b54a043550107a058df (MD5) Previous issue date: 2012-02-28 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The study in vitro aims to determine the erosive potential of industrialized beverages orange on deciduous enamel, glass ionomer cement with high viscosity - Ketac Molar EasyMixTM - (GIC) and glass ionomer cement modified by resin - VitremerTM - (CIVMR),by changing the hardness and surface roughness. Were prepared 60 samples of each surface divided into six groups: control, C5 and C15, orange drink with soy,S5 and S15, and orange drink, L5 and L15. For five days every group suffered erosive challenge (immersion - 6h storage - immersion - 6h storage - immersion - 12 hours of storage) and immersion time ranged from 5 to 15 minutes. The initial surface microhardness (ISM) and final (FSM) was measured using a microhardness, calibrated to make indentations with a load of 50g/5s tipped endentadora Knoop, five indentations were made by CP. The initial surface roughness (ISR) and final (FSR) was measured using a roughness of contact, five readings were made by sample.The difference in values of microhardness (FSM - ISM) between the groups was significant (p <0.05 - Student's t) for all groups IVC, the IVC-MR this difference was not significant (p> 0.05) S5 in the treatment, Deciduous Enamel and this difference was not significant (p> 0.05) in the C5 and C15. The difference in roughness values (FSR - ISR) between groups was significant (p <0.05 - Student's t) for all the CIV-MR groups, the MIC for this difference was not significant (p> 0.05) C5 group, Deciduous Enamel and this difference was not significant (p> 0.05) in the C5 and C15.Concluding that both industrialized beverages tested are orange erosive deciduous enamel and glass ionomer cements and that in times of five and fifteen minutes of soaking the change of surface microhardness and surface roughness was similar between groups. / Este estudo, in vitro, tem por objetivo determinar o potencial erosivo de bebidas industrializadas de laranja sobre o esmalte decíduo, cimento de ionômero de vidro de alta viscosidade – Ketac Molar EasyMixTM - (CIV) e cimento de ionômero de vidro modificado por resina - VitremerTM - (CIV-MR), através da alteração da microdureza e rugosidade superficial. Foram confeccionados 60 corpos de prova de cada superfície divididos em seis grupos: controle, C5 e C15, bebida de laranja com soja, S5 e S15, e bebida de laranja, L5 e L15. Durante cinco dias todos os grupos sofreram desafio erosivo (imersão – 6h de armazenamento – imersão – 6h de armazenamento – imersão – 12h de armazenamento) e o tempo de imersão variou entre 5 e 15 minutos. A microdureza superficial inicial (MSI) e final (MSF) foi verificada com microdurômetro, calibrado para realizar endentações com uma carga de 50g/5s com ponta endentadora Knoop, foram realizadas cinco endentações por CP. A rugosidade superficial inicial (RSI) e final (RSF) foi verificada utilizando-se um rugosímetro de contato, foram realizadas cinco leituras por CP. A diferença de valores de microdureza superficial (MSF-MSI) entre os grupos foi significativa (p<0,05 – t de Student) para todos os grupos CIV, o CIV-MR esta diferença não foi significativa (p>0,05) no tratamento S5, e no Esmalte Decíduo esta diferença não foi significativa (p>0,05) nos grupos C5 e C15. A diferença dos valores de rugosidade (RSF – RSI) entre os grupos foi significativa (p<0,05 – t de Student) para todos os grupos CIV-MR, para o CIV esta diferença não foi significativa (p>0,05) no grupo C5,e no Esmalte Decíduo esta diferença não foi significativa (p>0,05) nos grupos C5 e C15. Concluindo-se que as duas bebidas industrializadas de laranja testadas são erosivas ao esmalte decíduo e aos cimentos de ionômero vidro e que nos tempos de cinco e quinze minutos de imersão a alteração de microdureza superficial e de rugosidade superficial foi semelhante entre os grupos.
112

Influência do laser de CO2 associado ao fluoreto estanhoso no controle da erosão induzida por ácido clorídrico em esmalte de dentes decíduos-análise do desgaste e da permeabilidade / Influence of CO2 laser associated to stannous fluoride in the erosion control induced by hydrochloric acid on enamel of primary teeth wear and permeability analysis.

Cristiane Tomaz Rocha 14 January 2011 (has links)
Diante da importância e prevalência da erosão em crianças, devido principalmente ao refluxo gastroesofágico e da ausência de estudos na literatura sobre os efeitos do laser de CO2 no controle da erosão induzida por ácido clorídrico, o objetivo deste estudo foi determinar a influência in vitro de diferentes potências do laser de CO2 associado ao fluoreto estanhoso a 0,4% no controle da erosão induzida por ácido clorídrico em esmalte de dentes decíduos, por meio da análise do desgaste e da permeabilidade. Sessenta dentes decíduos foram utilizados para a obtenção de 120 fragmentos de esmalte (3x3 mm). Os fragmentos foram planificados, polidos e montados em blocos de resina acrílica. Duas fitas adesivas foram colocadas na superfície, deixando uma área de 3x1mm2 exposta. Para a formação das lesões de erosão, os espécimes foram submetidos a um desafio ácido de 4 ciclos por 2 minutos cada, com solução de ácido clorídrico a 0,01 M (pH 2). A análise do desgaste inicial foi calculada por perfilometria óptica e usada para selecionar 104 espécimes. Estes foram aleatoriamente divididos em 8 grupos, de acordo com a aplicação de flúor (presente- gel de fluoreto estanhoso a 0,4% e ausente-controle) e potência do laser de CO2 (sem irradiação-controle, 0,5 W, 1 W, 1,5 W). Metade dos espécimes foram submetidos a uma única aplicação do gel fluoretado por 1 minuto com o auxílio de um microbrush. A irradiação com laser de CO2 foi realizada no modo ultrapulso, duração do pulso de 100µs e desfocado a uma distância de 4 mm do esmalte. Após a realização dos tratamentos, desafios erosivos sucessivos foram realizados durante 5 dias, utilizando o mesmo protocolo descrito anteriormente. A análise do desgaste final foi calculada por perfilometria óptica. Para análise da permeabilidade, os espécimes foram submetidos a um método de coloração histoquímica, utilizando-se soluções de sulfato de cobre e de ácido rubeânico. Da região delimitada, obtiveram-se secções que foram digitalizadas sob microscopia óptica e submetidas à avaliação da penetração de íons cobre em relação à espessura total do esmalte. Foram realizadas, em cada secção, cinco avaliações da penetração dos íons cobre, totalizando quinze leituras por espécime. Os dados da análise do desgaste foram submetidos a ANOVA a dois critérios e a interação entre os fatores aplicação de flúor e potência do laser de CO2 foi significativa (p = 0,046). Entretanto, pela análise da permeabilidade, a ANOVA a dois critérios não mostrou interação entre os fatores (p = 0,591). Efeito significativo do fator potência do laser de CO2 foi observado (p = 0,037), sendo que a potência de 1,5 W proporcionou aumento da permeabilidade do esmalte quando comparado a 0,5 W. A correlação entre as análises do desgaste e permeabilidade não foi significativa (p = 0,699). Conclui-se, pela análise do desgaste, que o laser de CO2 com 1W associado ao fluoreto estanhoso a 0,4% pode ser um método efetivo no controle da erosão induzida por ácido clorídrico em esmalte de dentes decíduos. A análise da permeabilidade não evidenciou sinergismo entre a aplicação de fluoreto estanhoso a 0,4% e as potências do laser de CO2. A potência do laser de CO2 de 0,5 W proporcionou menor permeabilidade no esmalte erodido quando comparada a de 1,5 W. A análise do desgaste não apresentou correlação com a análise da permeabilidade em esmalte de dentes decíduos submetidos a desafios erosivos por ácido clorídrico. / Facing importance and prevalence of erosion in children, mainly due to gastroesophageal reflux and absence of studies evaluating effects of CO2 laser in control erosion induced by hydrochloric acid, the aim of this study was to determine in vitro influence of different CO2 laser powers associated with 0.4% stannous fluoride erosion control induced by hydrochloric acid on enamel of primary teeth by wear and permeability analysis. Sixty primary teeth were used to obtain 120 enamel fragments (3x3 mm). Fragments were flatenned, polished and fixed in resin blocks. Two piece of tapes were placed on the surface, leaving an exposed area 3x1mm2. For the formation of erosion lesions, specimens were submitted to an acid challenge by 4 cycles of 2 minutes each, with 0.01 M hydrochloric acid solution (pH 2). Initial wear analysis was calculated by optical profilometry and used to select 104 specimens. These were randomly assigned into 8 groups according to fluoride application (present-gel 0.4% stannous fluoride and absent-control) and CO2 laser power (no irradiation control, 0.5 W, 1 W, 1.5 W). Half of specimens were submitted to a single fluoride application for 1 min with microbrush. CO2 laser irradiation was performed in a ultrapulsed, 100µs pulse duration at a distance of 4 mm of enamel. After treatments, erosive challenges were performed for 5 successive days using the same protocol described above. Final wear analysis was calculated by optical profilometry. For permeability analysis, specimens were submitted to histochemical coloring method, using copper sulphate and acid rubeanic solutions. It was obtained sections from exposed area which were scanned under light microscopy and evaluated for copper ions penetration in relation to the total thickness of enamel. In each section, five evaluations of copper ions penetration were performed, resulting in fifteen readings per specimen. Data wear analysis were submitted to two-way ANOVA and interaction between factors fluoride application and CO2 laser power was significant (p = 0.046). However, permeability analysis, two-way ANOVA showed no interaction between factors (p = 0.591). Significant effect of CO2 laser power was found (p = 0.037), and 1.5 W power provided an increase of enamel permeability compared to 0.5 W. Correlation between wear and permeability analysis was not significant (p = 0.699). CO2 laser using 1W associated with 0.4% stannous fluoride can be an effective method to erosion control induced by hydrochloric acid on enamel of primary teeth. Permeability analysis showed no synergic effect between 0.4% stannous fluoride application and CO2 laser powers. CO2 laser power of 0.5 W provided the lowest permeability of enamel erosion compared to 1.5 W. Wear analysis showed no correlation with permeability analysis of primary teeth enamel submitted to erosion by hydrochloric acid challenges.
113

Microtração de sistemas adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após preparo cavitário com laser de Er: YAG: avaliação in vitro / Microtensile bond strength of selfetch adhesive systems in demineralised dentin of primary teeth after Er: YAG laser irradiation: in vitro evaluation

Cintia Guimaraes de Almeida 01 June 2011 (has links)
O objetivo deste estudo foi avaliar a resistência à microtração de adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após a irradiação com laser de Er: YAG. Oitenta e dois molares decíduos tiveram a porção oclusal seccionada transversalmente e os espécimes foram desgastados com lixas de carbeto de silício de granulações 360 e 600 até expor a dentina. Os 60 espécimes utilizados no teste de microtração foram preenchidos com resina composta fotopolimerizável na região correspondente à câmara pulpar, isolados com esmalte cosmético mantendo a superfície dentinária exposta e, em seguida imersos em solução desmineralizante por seis dias em estufa a 37&deg; C para indução de lesão de cárie artificial em dentina. Após a desmineralização, os espécimes foram preparados com laser de Er: YAG (n=30) com os parâmetros de 260 mJ, 3 Hz, 47 J/cm2, 0,81W e com broca de aço esférica em baixa rotação (n=30). Sobre as superfícies preparadas foram aplicados três sistemas adesivos autocondicionantes Clearfil SE Bond (Kuraray); Adper&trade; Easy One (3M ESPE) e Adper&trade; SE Plus (3M ESPE) e, em seguida foram confeccionados platôs de resina composta Z 250. Após termociclagem (500 ciclos), os corpos de prova foram seccionados produzindo palitos de aproximadamente 1 mm2 de área transversal, que foram submetidos ao teste de microtração e os valores obtidos foram analisados estatisticamente através de ANOVA e teste de Duncan (5%). A análise qualitativa dos tipos de fraturas foi realizada por meio de lupa estereoscópica (aumento de 40X) e da interface adesiva por meio de MEV. Para a análise química da dentina através de espectroscopia no infravermelho por transformada de Fourier (FTIR), foram utilizados discos de dentina após o preparo superficial com a broca (n=5) e com o laser (n=5), e comparadas com as análises de tecido dentinário sadio e desmineralizado obtidas dos mesmos espécimes. Os resultados foram submetidos ao teste estatístico t&minus;Student (5%). O teste de microtração demonstrou que houve diferença significativa entre os adesivos, sendo que o grupo controle (Clearfil e broca) obteve o melhor desempenho comparativamente a todos os grupos avaliados. O preparo com laser de Er: YAG afetou adversamente a adesão para os sistemas adesivos Clearfil SE Bond e Adper&trade; Easy One em comparação com os grupos preparados com broca. Nos grupos irradiados com laser, o sistema adesivo Clearfil SE Bond foi o que proporcionou o maior valor médio de microtração. Os resultados da FTIR demonstraram que, com a irradiação da dentina desmineralizada, houve um decréscimo na quantidade de matéria orgânica e de carbonato em relação ao grupo da dentina sadia. No substrato preparado com broca, observouse aumento da matéria orgânica e redução de carbonato. Concluise que, em relação aos sistemas adesivos, o Clearfil SE Bond teve o melhor desempenho no teste de resistência à microtração em dentina de dentes decíduos. A irradiação com laser de Er: YAG afetou adversamente a adesão dos sistemas adesivos Clearfil SE Bond e Adper&trade; Easy One. A irradiação com laser de Er:YAG decresceu de maneira significativa a quantidade de matéria orgânica presente na dentina de dentes decíduos. / The purpose of this study was to evaluate the microtensile bond strength of three selfetch adhesives systems to demineralized dentin of primary teeth after irradiation with Er: YAG laser. Eighty two primary molars had the occlusal enamel sectioned and the specimens were grounded with silicon carbide sandpaper grits of 360 and 600 to expose the dentin. The 60 specimens used in the microtensile test were filled with composite resin in the region corresponding to the pulp chamber, insulated with nail varnish keeping the exposed dentin surface and then immersed in demineralizing solution for six days in a stove at 37 Celsius degrees in order to produce artificial carieslike lesions in dentin. After demineralization, the specimens were prepared with Er: YAG (n = 30) using as parameters 260 mJ, 3 Hz, 47 J/cm2, 0.81 W and a round steel drill at low speed (n = 30 ). On the prepared surfaces were applied three self&minus;etch adhesives systems Clearfil SE Bond (Kuraray); Adper&trade; Easy One (3M ESPE) and AdperTM SE Plus (3M ESPE) and then plateaus of composite resin Z 250 were built up. After thermocycling (500 cycles), specimens were sectioned to produce multiple sticks of approximately 1 mm2 crosssectional area, which were subjected to microtensile test and the data were analyzed with ANOVA and Duncan test at a significance level of 0.05. The qualitative analysis of the types of fractures was performed using a stereomicroscope (X40 magnification) and the morphological analyses of adhesive interfaces were performed by scanning electron microscopy (SEM). Chemical analysis of the dentin by Fourier transform infrared spectroscopy (FTIR) were performed in dentin discs after surface preparation with the steel drill (n = 5) and laser (n = 5) and compared with the values previously obtained from the analysis of sound and demineralized dentin tissue in the same specimens. The results were analyzed by Student\'s t&minus;test at a significance level of 0.05. Regarding the microtensile bond strength there was a significant difference between the adhesive systems, and the control group (Clearfil and steel drill) had the best performance compared to all groups. Er: YAG laser irradiation adversely affected bond strength to the Clearfil SE Bond and Adper&trade; Easy One compared with the groups prepared with steel drill. In the laser groups Clearfil SE Bond reached the highest average bond strength. Results of FTIR analysis showed that the hydration of dentin remained normal after both preparations. With laser irradiation of demineralized dentin there was a decrease in the amount of organic matter and carbonate in relation to the group of sound dentin. The analyses of substrate prepared with steel drill showed an increase in organic matter and reduction of carbonate. The conclusion in relation to adhesive systems was that Clearfil SE Bond had the best performance in microtensile bond strength in primary teeth dentin. Laser irradiation adversely affected the bond strength of Clearfil SE Bond and Adper&trade; Easy One selfetch adhesive systems. Laser irradiation had significantly reduced the organic matter content in dentin of deciduous teeth.
114

Influência do laser de CO2 associado ao fluoreto estanhoso no controle da erosão induzida por ácido clorídrico em esmalte de dentes decíduos-análise do desgaste e da permeabilidade / Influence of CO2 laser associated to stannous fluoride in the erosion control induced by hydrochloric acid on enamel of primary teeth wear and permeability analysis.

Rocha, Cristiane Tomaz 14 January 2011 (has links)
Diante da importância e prevalência da erosão em crianças, devido principalmente ao refluxo gastroesofágico e da ausência de estudos na literatura sobre os efeitos do laser de CO2 no controle da erosão induzida por ácido clorídrico, o objetivo deste estudo foi determinar a influência in vitro de diferentes potências do laser de CO2 associado ao fluoreto estanhoso a 0,4% no controle da erosão induzida por ácido clorídrico em esmalte de dentes decíduos, por meio da análise do desgaste e da permeabilidade. Sessenta dentes decíduos foram utilizados para a obtenção de 120 fragmentos de esmalte (3x3 mm). Os fragmentos foram planificados, polidos e montados em blocos de resina acrílica. Duas fitas adesivas foram colocadas na superfície, deixando uma área de 3x1mm2 exposta. Para a formação das lesões de erosão, os espécimes foram submetidos a um desafio ácido de 4 ciclos por 2 minutos cada, com solução de ácido clorídrico a 0,01 M (pH 2). A análise do desgaste inicial foi calculada por perfilometria óptica e usada para selecionar 104 espécimes. Estes foram aleatoriamente divididos em 8 grupos, de acordo com a aplicação de flúor (presente- gel de fluoreto estanhoso a 0,4% e ausente-controle) e potência do laser de CO2 (sem irradiação-controle, 0,5 W, 1 W, 1,5 W). Metade dos espécimes foram submetidos a uma única aplicação do gel fluoretado por 1 minuto com o auxílio de um microbrush. A irradiação com laser de CO2 foi realizada no modo ultrapulso, duração do pulso de 100µs e desfocado a uma distância de 4 mm do esmalte. Após a realização dos tratamentos, desafios erosivos sucessivos foram realizados durante 5 dias, utilizando o mesmo protocolo descrito anteriormente. A análise do desgaste final foi calculada por perfilometria óptica. Para análise da permeabilidade, os espécimes foram submetidos a um método de coloração histoquímica, utilizando-se soluções de sulfato de cobre e de ácido rubeânico. Da região delimitada, obtiveram-se secções que foram digitalizadas sob microscopia óptica e submetidas à avaliação da penetração de íons cobre em relação à espessura total do esmalte. Foram realizadas, em cada secção, cinco avaliações da penetração dos íons cobre, totalizando quinze leituras por espécime. Os dados da análise do desgaste foram submetidos a ANOVA a dois critérios e a interação entre os fatores aplicação de flúor e potência do laser de CO2 foi significativa (p = 0,046). Entretanto, pela análise da permeabilidade, a ANOVA a dois critérios não mostrou interação entre os fatores (p = 0,591). Efeito significativo do fator potência do laser de CO2 foi observado (p = 0,037), sendo que a potência de 1,5 W proporcionou aumento da permeabilidade do esmalte quando comparado a 0,5 W. A correlação entre as análises do desgaste e permeabilidade não foi significativa (p = 0,699). Conclui-se, pela análise do desgaste, que o laser de CO2 com 1W associado ao fluoreto estanhoso a 0,4% pode ser um método efetivo no controle da erosão induzida por ácido clorídrico em esmalte de dentes decíduos. A análise da permeabilidade não evidenciou sinergismo entre a aplicação de fluoreto estanhoso a 0,4% e as potências do laser de CO2. A potência do laser de CO2 de 0,5 W proporcionou menor permeabilidade no esmalte erodido quando comparada a de 1,5 W. A análise do desgaste não apresentou correlação com a análise da permeabilidade em esmalte de dentes decíduos submetidos a desafios erosivos por ácido clorídrico. / Facing importance and prevalence of erosion in children, mainly due to gastroesophageal reflux and absence of studies evaluating effects of CO2 laser in control erosion induced by hydrochloric acid, the aim of this study was to determine in vitro influence of different CO2 laser powers associated with 0.4% stannous fluoride erosion control induced by hydrochloric acid on enamel of primary teeth by wear and permeability analysis. Sixty primary teeth were used to obtain 120 enamel fragments (3x3 mm). Fragments were flatenned, polished and fixed in resin blocks. Two piece of tapes were placed on the surface, leaving an exposed area 3x1mm2. For the formation of erosion lesions, specimens were submitted to an acid challenge by 4 cycles of 2 minutes each, with 0.01 M hydrochloric acid solution (pH 2). Initial wear analysis was calculated by optical profilometry and used to select 104 specimens. These were randomly assigned into 8 groups according to fluoride application (present-gel 0.4% stannous fluoride and absent-control) and CO2 laser power (no irradiation control, 0.5 W, 1 W, 1.5 W). Half of specimens were submitted to a single fluoride application for 1 min with microbrush. CO2 laser irradiation was performed in a ultrapulsed, 100µs pulse duration at a distance of 4 mm of enamel. After treatments, erosive challenges were performed for 5 successive days using the same protocol described above. Final wear analysis was calculated by optical profilometry. For permeability analysis, specimens were submitted to histochemical coloring method, using copper sulphate and acid rubeanic solutions. It was obtained sections from exposed area which were scanned under light microscopy and evaluated for copper ions penetration in relation to the total thickness of enamel. In each section, five evaluations of copper ions penetration were performed, resulting in fifteen readings per specimen. Data wear analysis were submitted to two-way ANOVA and interaction between factors fluoride application and CO2 laser power was significant (p = 0.046). However, permeability analysis, two-way ANOVA showed no interaction between factors (p = 0.591). Significant effect of CO2 laser power was found (p = 0.037), and 1.5 W power provided an increase of enamel permeability compared to 0.5 W. Correlation between wear and permeability analysis was not significant (p = 0.699). CO2 laser using 1W associated with 0.4% stannous fluoride can be an effective method to erosion control induced by hydrochloric acid on enamel of primary teeth. Permeability analysis showed no synergic effect between 0.4% stannous fluoride application and CO2 laser powers. CO2 laser power of 0.5 W provided the lowest permeability of enamel erosion compared to 1.5 W. Wear analysis showed no correlation with permeability analysis of primary teeth enamel submitted to erosion by hydrochloric acid challenges.
115

Influência da aceleração de presa por meio de ultrassom, luz halógena e diodo emissor de luz nas propriedades e resistência de união à dentina de cimentos de iônomero de vidro / Influence of accelaration setting reaction by ultrasound, halogen light and light emitted diode on properties and bond strength of glass ionomer cement

Yoshioka, Laysa 17 February 2016 (has links)
Este estudo avaliou a influência da aceleração de presa de cimentos de ionômero de vidro de alta viscosidade (CIVAV) por meio de ultrassom, luz halógena e diodo emissor de luz (LED). Para as análises, os espécimes foram divididos em nove grupos de acordo com o material - CIVAV versão pó-líquido (Fuji Gold Label IX GPGC Corp.), CIVAV versão encapsulado (Equia Fill - GC Corp.) e a aceleração de presa inicial - controle negativo; aplicação de ultrassom por 20s, irradiados com luz halógena por 60s, irradiados com LED por 60s, além de um grupo controle positivo de cimento de ionômero de vidro modificado por resina (CIVMR) versão pó-líquido (Fuji II LC - GC Corp.). Para o teste de resistência flexural (RF) foram preparados 90 espécimes (25x2x2mm) (n=10), após armazenamento em água destilada por 24h a 37°C, os espécimes foram submetidos ao teste de RF de três pontos (1mm/min). Para a análise de rugosidade superficial (RS), 45 espécimes (n=5) previamente preparados para o teste de RF, foram selecionados aleatoriamente em cada grupo. A medida da RS (parâmetros Sa e Ra) do corpo de prova foi dada pela média de 5 leituras realizadas na superfície. Para o teste de resistência de união (RU), 90 molares decíduos (n=10) foram selecionados e cânulas de polietileno foram posicionadas sobre as superfícies planas de dentina pré-tratadas, preenchidas por um dos CIV e aplicado um dos aceleradores de presa de acordo com o grupo experimental. Após armazenamento em água destilada por 24h a 37°C, os espécimes foram submetidos ao teste de microcisalhamento (1,0 mm/min). O padrão de fratura foi analisado em microscópio esteroscópico (400 X). Para avaliar a interação dentina-CIV, foram selecionados 27 caninos decíduos (n=3), foi preparada uma cavidade (4x2x2mm) na superfície vestibular, então a cavidade foi restaurada com um dos CIV propostos pelo estudo para então ser aplicado um dos aceleradores de presa de acordo com o grupo experimental. Após armazenados por 48h a 37ºC e 100% de umidade relativa, os dentes foram seccionados, resultando em fatias com 1mm de espessura. A fatia obtida foi observada em MEV para avaliar qualitativamente possíveis diferenças estruturais. Os valores dos testes de RF, RS e RU foram submetidos a Análise de Variância e teste de Tukey (?=5%). Como resultados na RF, a reação de presa com ultrassom resultou em maiores valores e semelhantes aos grupos controle negativo, independente da forma de apresentação do CIVAV. Para RS (Ra) o grupo Fuji IX mostrou maiores valores quando houve aplicação de ultrassom. Os demais grupos apresentaram resultados semelhantes. Para o parâmetro Sa houve diferença estatística em relação a apresentação do material e Equia Fill apresentou maiores valores de Sa. Para o teste de RU Fuji IX apresentou melhor desempenho nos grupos que receberam ativação por ultrassom e LED. Equia Fill não foi influenciado por nenhum tipo de fonte externa na RU. Com relação ao padrão de fratura, as fraturas adesivas/mistas apresentaram maior frequência independente do grupo experimental. As imagens de MEV mostram a região de interação do material com a dentina. Concluímos que o uso do ultrassom influenciou positivamente na RF, porém gerou maiores valores de RS (Ra) no grupo Fuji IX. Equia Fill tem maiores valores de RS (Sa). LED e ultrassom influenciaram positivamente o grupo Fuji IX na RU. / This study evaluated the influence of acceleration setting reaction by ultrasound, halogen light and light emitting diode (LED). For the analysis, the specimens were divided into nine groups according to the material - HVGIC powder-liquid version (Fuji Gold Label IX GP- GC Corp.), HVGIC encapsulated version (Equia Fill - GC Corp.) and the acceleration setting reaction original - negative control; ultrasound application for 20 seconds, irradiated with halogen light for 60 seconds, irradiated with LED for 60 seconds, and a positive control group of resin modified glass ionomer cement (RMGIC) powder-liquid version (Fuji II LC - GC Corp.) . For flexural strength test (FS) there were prepared 90 specimens (25x2x2mm) (n=10). After storage in water for 24 hours at 37°C, specimens were subjected to the FS test three points (1min/min). For the surface roughness analysis (SR), 45 specimens (n=5) previously prepared to the FS test were randomly selected from each group, and the average of 5 readings was analysed in Sa and Ra parameters. For the bond strength test (BS) 90 primary molars (n = 10) were selected and polyethylene cannulae were positioned on the flat pretreated dentin surface filled by one of the GICs and apply one of the setting reaction accelerators according to the experimental group. After storage in distilled water for 24 hours at 37°C, specimens were subjected to microshear test (1.0 mm/min). The fracture pattern was analyzed in stereomicroscope (400X). To evaluate the interaction dentin-GIC were selected 27 deciduous canines (n= 3), a cavity (4x2x2mm) was prepared in the buccal surface and then restored with the GIC accordingly to groups. After stored for 48 hours at 37°C and 100% relative humidity, the teeth were sectioned, resulting in slices with 1mm thickness. The slice obtained was observed by scanning electron microscope (SEM) to assess qualitatively possible structural differences. The values of FS testing, SR and BS were submitted to ANOVA and Tukey\'s test (? = 5%). As a result the FS, the ultrasound with setting reaction resulted in higher values and similar to the negative control group, regardless of the format of the HVGIC. SR for Ra parameter Fuji IX group showed higher values when there was application of ultrasound. The other groups showed similar results. For Sa parameter was no statistical difference regarding the presentation of material and Equia Fill showed higher Sa. For the BS Fuji IX test performed better in the groups receiving activation with Ultrasound and LED. Equia Fill was not influenced by any outside source. Regarding the fracture pattern, the adhesive / mixed fractures prevailed, regardless of experimental group. The SEM images showed the interaction region of the material to dentin. We conclude that the use of ultrasound positively influences the RF, but generated higher SR values (Ra) in Fuji IX group. Equia Fill SR has higher values f(Sa). LED ultrasound and positively influenced the Fuji IX group in the BS.
116

Efeito da condição do substrato e do tempo de condicionamento na estabilidade da união de sistemas adesivos à dentina de dentes decíduos / Effect of substrate condition and etching time on the bonds stability of adhesive systems to dentin of primary teeth

Lenzi, Tathiane Larissa 03 May 2013 (has links)
Este estudo objetivou investigar a influência da redução do tempo de condicionamento na união de sistemas adesivos à dentina hígida e afetada por cárie de dentes decíduos, por meio de testes de microtração, nanoinfiltração e avaliação micromorfológica da interface adesiva. A superfície dentinária de 48 segundos molares decíduos foi exposta e os dentes divididos aleatoriamente em 8 grupos experimentais de acordo com o substrato (dentina hígida e afetada por cárie ciclagem de pH por 14 dias), sistema adesivo (Adper Single Bond 2 adesivo convencional de dois passos e Clearfil SE Bond - sistema autocondicionante de dois passos) e tempo de condicionamento (recomendado pelo fabricante e metade do tempo). Desta forma, o adesivo Adper Single Bond 2 foi aplicado à dentina após condicionamento com ácido fosfórico a 35% por 15 ou 7 segundos e o agente de união do Clearfil SE Bond após 20 ou 10 segundos de aplicação do primer. Blocos de resina composta (Filtek Z250) foram confeccionados e, após 24 horas de armazenamento em água destilada, os dentes foram seccionados para obtenção de espécimes com área de secção transversal de aproximadamente 0,8 mm2. Metade dos espécimes foi submetida imediatamente ao teste de microtração e a outra metade após 12 meses de armazenamento em água destilada. O padrão de fratura foi avaliado em estereomicroscópio com aumento de 400x. Dois espécimes de cada dente nos respectivos períodos de armazenamento foram imersos em nitrato de prata amoniacal por 24 horas e revelados (8 horas) para avaliação da nanoinfiltração em microscopia eletrônica de varredura. Adicionalmente, dois dentes para cada grupo experimental (n=16) foram preparados como descrito para o teste de microtração e seccionados perpendicularmente à interface adesiva, após 24 horas, para análise da micromorfologia e espessura da camada híbrida. Os valores de resistência de união, expressos em megapascal (MPa), foram submetidos à Análise de Variância (ANOVA) e teste de Tukey ( = 0,05). As demais avaliações foram descritivas. Os sistemas adesivos apresentaram valores similares de resistência de união imediata. Decréscimo dos valores de resistência de união ocorreu após 12 meses de armazenamento em água, exceto para o adesivo Clearfil SE Bond em substrato hígido. A adesão à dentina afetada foi menor em comparação à dentina hígida. A nanoinfiltração também foi mais pronunciada neste substrato. O tempo de condicionamento influenciou apenas a adesão do sistema adesivo Adper Single Bond 2. Maiores valores de resistência de união e menor infiltração de nitrato de prata na interface adesiva foram observados quando o tempo de condicionamento ácido foi reduzido pela metade, independente do substrato. Camadas híbridas mais finas foram produzidas quando a dentina decídua foi condicionada por 7 segundos, especialmente em dentina afetada. Predomínio de fratura adesiva/mista foi observado para todos os grupos experimentais. Em conclusão, o efeito da redução no tempo de condicionamento é material dependente e resulta em maior estabilidade da união de sistema adesivo convencional de dois passos à dentina hígida e afetada de dentes decíduos. / This study aimed to investigate the influence of shortening the etching time on bond of adhesive systems to sound and caries-affected dentin of primary teeth by microtensile and nanoleakage tests, and micromorphological evaluation of the adhesive interface. The dentinal surface of 48 second primary molars was exposed and the teeth were randomly assigned to 8 experimental groups according to substrate (sound and caries-affected dentin - pH-cycling for 14 days), adhesive system (Adper Single Bond 2 two-step etch-and-rinse adhesive system and Clearfil SE Bond two step self-etch adhesive system) and etching time (recommend by manufacturers and half-reduced time). Thus, the adhesive Adper Single Bond 2 was applied to dentin after 35% phosphoric acid etching for 15 or 7 seconds, and the bond of Clearfil SE Bond after 20 or 10 seconds of primer application. Composite resin blocks (Filtek Z250) were built and, after 24 hours of storage in distilled water, the teeth were sectioned to obtain specimens with cross-sectional area of approximately 0.8 mm2. Half of the specimens were immediately subjected to microtensile test and the other half after 12 months of storage in distilled water. The fracture pattern was evaluated with a stereomicroscope at 400x magnification. Two specimens from each tooth in the respective storage periods were immersed in ammoniacal silver nitrate for 24 hours and revealed (8 hours) to evaluate the nanoleakage in scanning electron microscope. Additionally, two teeth for each experimental group (n=16) were prepared as described for the microtensile test and perpendicularly sectioned to the adhesive interface, after 24 hours, for analysis of micromorphology and thickness of the hybrid layer. Bond strength values, expressed in megapascal (MPa), were submitted to Analysis of Variance (ANOVA) and Tukeys tests ( = 0.05). Other evaluations were descriptive. The adhesive systems presented similar immediate bond strength values. A decrease in bond strength values occurred after 12 months of water storage, except for Clearfil SE Bond in sound substrate. Bonding to caries-affected dentin was lower compared to sound dentin. The nanoleakage was also more pronounced in this substrate. Etching time only influenced the bonding of the adhesive system Adper Single Bond 2. Higher bond strength values and lower infiltration of silver nitrate into adhesive interface were observed when the etching time was half-reduced, irrespective of the substrate. Thinner hybrid layers were produced when the primary dentin was acid etched for 7 seconds, especially in caries-affected dentin. Predominance of adhesive/mixed fracture was observed for all experimental groups. In conclusion, the effect of shortening the etching time is material dependent and results in higher bond stability of two-step etch-and-rinse adhesive system to sound and caries-affected dentin of primary teeth.
117

Avaliação da precisão de guias cirúrgicos para implantes osteointegrados obtidos a partir de prototipagem rápida

MENEZES, Lucas Machado de 29 April 2008 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-02-14T15:41:38Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoPrecisaoGuias.pdf: 4828751 bytes, checksum: 4f67a722f8937eec4e565f5418e64246 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-04-30T13:45:33Z (GMT) No. of bitstreams: 2 Dissertacao_AvaliacaoPrecisaoGuias.pdf: 4828751 bytes, checksum: 4f67a722f8937eec4e565f5418e64246 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2014-04-30T13:45:33Z (GMT). No. of bitstreams: 2 Dissertacao_AvaliacaoPrecisaoGuias.pdf: 4828751 bytes, checksum: 4f67a722f8937eec4e565f5418e64246 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2008 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O planejamento implantodôntico exige precisão e confiabilidade. A prototipagem rápida oferece a possibilidade de transferir o planejamento para o campo operatório, sendo este um importante aliado no tratamento cirúrgico. O presente estudo tem por objetivo avaliar a precisão de guias cirúrgicos obtidos através de tomografia computadorizada, planejamento em software para implantodontia (Implantviwer – Anne Solutions ltda.) e prototipagem rápida, avaliando a angulação e a posição horizontal dos implantes e ainda comparar guias com apoio ósseo e guias com apoio gengival. Foram selecionadas cinco mandíbulas humanas secas, que foram fixadas a um crânio e realizadas as tomografias computadorizadas, o planejamento dos implantes e os guias confeccionados apartir de prototipagem. Após a instalação de vinte implantes foram realizadas novas tomografias e comparação das medidas referentes a angulação e posicionamento horizontal dos implantes através da sobreposição das imagens pré e pós operatórias. Tais resultados foram submetidos a análise estatística pelo teste T para amostras dependentes e análise de variância de Friedman com índice de significância de 95%. Observou-se uma discrepância média de angulação de 2,60º (DP = 3,20º) e de 0.40 mm (DP = 0,51 mm) para o posicionamento horizontal nos guias com apoio sobre gengiva artificial e 5,30º (DP = 3,88º) e 0,70 mm (DP = 0,82 mm) para os guias com apoio ósseo . Os guias com apoio ósseo e gengival apresentaram diferença estatística entre si apenas quanto a angulação. Os guias cirúrgicos para implantes osteointegrados construídos apartir de prototipagem rápida oferecem precisão na transferência do planejamento para o campo operatório e sua utilização poderá aumentar a previsibilidade dos resultados, assim como facilitar a cirurgia e minimizar a intervenção cirúrgica. / The implantodontic planning demands precision and trustworthiness, the rapid prototyping offers the possibility to transfer the planning to the surgical field, being this an important ally in the surgical treatment. The present study it has for objective to evaluate the precision of surgical guides constructed through computerized tomography, planning in software for implantodontics and fast prototyping and compare bone supported guides to gingival tissue supported guides. Five dry human mandibulas had been selected, who had been fixed to an ideal skull and carried through the computerized tomograph, the implant planning and the prototyped guides. After the installation of the twenty implants, had been carried through new tomographs and comparison of the referring measures the axis and horizontal positioning of the implantations through the overlapping of the images before and after surgery, such results forms submitted to the statistic analysis for test T for dependent samples and Friedman´s variance analysis, with index of significance of 95%. An average discrepancy in axis of 2,60º (SD = 3,36º) and of 0,40 mm (SD = 0,68mm) for the horizontal positioning was observed to the gingival tissue supported guides and 5,30º (SD = 3,88º) and 0,70 mm (SD = 0,82mm) to bone supported guides, bone supported guides and gingival tissue supported guides did not demonstrated statistical differences. The surgical guides for osteointegrated dental implants constructed rapid prototyping offer precision in the transference of the planning for the surgical field and its use will be able to increase the previsibility of the results, as well as facilitating the surgery and minimizing the intervention.
118

Estudo epidemiológico de ocorrência da má oclusão na dentição decídua de crianças da rede pública e privada do município de Belém-Pará

NORMANDO, Thiene Silva January 2008 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-02-14T15:57:12Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoEpidemiologicoOcorrencia.pdf: 1859062 bytes, checksum: ade9da9d6574e9ab8e8747ee51a774c1 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-04-30T14:12:24Z (GMT) No. of bitstreams: 2 Dissertacao_EstudoEpidemiologicoOcorrencia.pdf: 1859062 bytes, checksum: ade9da9d6574e9ab8e8747ee51a774c1 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2014-04-30T14:12:24Z (GMT). No. of bitstreams: 2 Dissertacao_EstudoEpidemiologicoOcorrencia.pdf: 1859062 bytes, checksum: ade9da9d6574e9ab8e8747ee51a774c1 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2008 / A literatura evidencia que a má oclusão pode se manifestar desde os estágios mais precoces do desenvolvimento oclusal, e, na maioria dos tipos morfológicos, não apresenta auto-correção nos estágios posteriores do desenvolvimento oclusal. Para que políticas públicas possam ser adotadas no sentido de incluir a ortodontia preventiva e interceptativa nos programa de saúde bucal, visando beneficiar principalmente a parte da população menos favorecida, este trabalho teve como objetivo avaliar a prevalência da má oclusão na dentição decídua na cidade de Belém-PA, examinando crianças de escolas públicas e privadas, verificando a influência do nível sócio-econômico na manifestação da má oclusão. Para tanto, foram examinadas 652 crianças, de ambos os sexos, de 3 a 6 anos de idade, na fase de dentição decídua completa, matriculadas em préescolas da rede privada e da rede pública do ensino de Belém- Pará. Foi observada uma prevalência de 81,44% de má oclusão, sendo mais frequente nas crianças do gênero feminino da rede privada (p=0.01). A má- oclusão de Classe II foi mais prevalente, seguida da Classe I e da Classe III. Dentre os diferentes tipos morfológicos de má oclusão, a sobremordida e a mordida cruzada posterior foram mais prevalentes nas crianças da rede privada, em ambos os gêneros, enquanto o trespasse horizontal aumentado e a classe II, apresentaram uma maior ocorrência nas crianças da rede privada no gênero feminino. A má oclusão de Classe I e III foram mais freqüentes nas crianças do gênero feminino na rede pública. A mordida aberta anterior e a mordida cruzada anterior, mostraram comportamento semelhante nos dois grupos de escola, em ambos os gêneros. A perda precoce de dentes decíduos foi mais prevalente (p=0.000) nas crianças da rede pública em ambos os gêneros. Assim, pode-se concluir que a ocorrência da má oclusão na dentição decídua na cidade de Belém é muito alta; que o nível sócio-econômico exerce influência sobre a manifestação das más oclusões, pois essas foram mais freqüente nas crianças da rede privada do gênero feminino e que a ocorrência da perda precoce de dentes decíduos nas crianças da rede pública ainda apresenta um índice alarmante, decorrente provavelmente de uma política de saúde pública ineficiente, que atue em nível preventivo e interceptativo. / The literature shows that malocclusion can manifest it self from the earliest stages of occlusal development and, in most types morphologies, it shows no self-correction in the later stages of occlusal development. This study aimed to assess the prevalence of malocclusion in deciduous dentition in the city of Belém- PA, examining children from public and private schools, and to check the influence of socio-economic level in the manifestation of malocclusion, so that public policy can be adopted to include preventive and interceptative into oral health services, targeting mainly to benefit the least favoured part of the population. 652 children of both sexes were examined, 3 to 6 years of age in the deciduous dentitions stage, enrolled in pre-schools in the private network and public network of education in Belém-Pará. There was a prevalence of 81,44% of malocclusion, being more common in female children in the private network (p = 0.01). The Class II malocclusion was most prevalent, followed by Class I and Class III. Among the different types of morphological malocclusion, the overbite and the posterior crossbite were more prevalent in children from the private network for both genders, although the overjet and Class II, had a higher occurrence in females only in children from the private network . The Class I and III malocclusion were more common in female children in the public network. The anterior openbite and the anterior crossbite, showed similar trends in both groups of schools for both genders. The early loss of temporary teeth was more prevalent (p=0.000) among children of the public network for both genders. Thus we can conclude that the incidence of malocclusion in deciduous dentition in the city of Belém is very high, in addition the low socio-economic influences the expression of malocclusion because they were more frequent among female children in the private network; and that the occurrence of early loss of temporary teeth in children in the public network still has an alarming rate, due to an inefficient public health policy, which serve at the preventive and interceptative level.
119

Influência da dentina sadia e afetada por cárie na resistência de união de sistemas adesivos e cimentos de ionômero de vidro em dentes decíduos - estudo in vitro / Influence of sound or caries-affected dentin on the bond strength of adhesive systems and glass ionomer cements in primary teeth an in vitro study

Alves, Fabiana Bucholdz Teixeira 08 December 2010 (has links)
O objetivo deste estudo foi avaliar a influência do substrato dentinário sadio e afetado em dentes decíduos, após restaurações realizadas com diferentes materiais, na resistência de união e nanoinfiltração. Setenta e dois segundos molares receberam preparos padronizados na superfície oclusal e foram divididos aleatoriamente em dois grupos. Um grupo foi denominado dentina sadia [DS] (n=36), e o outro foi submetido ao desafio cariogênico artificial (ciclagem de pH) denominado dentina afetada [DA] (n=36). Posteriormente, os dentes foram restaurados (n=6) com os seguintes materiais: cimento de ionômero de vidro modificado por resina (CIVMR) com nanopartículas - KetacTM N100 [KN100], CIVMR - Vitremer [VI], cimento de ionômero de vidro de alta viscosidade (CIVAV) - KetacTM Molar Easy Mix [KME], Sistema Adesivo autocondicionante de passo único AdperTM Easy One Self-Etch Adhesive [EASY], sistema adesivo autocondicionante de dois passos - AdperTM SE Plus [SE], sistema adesivo com condicionamento ácido total - AdperTM Single Bond 2 [SB]. Os grupos dos sistemas adesivos receberam restauração com resina composta (Filtek Z250). Após 24 horas de armazenagem em água destilada (37ºC), os dentes foram seccionados no sentido vestíbulo-lingual e novos cortes no sentido mésiodistal de forma a obter palitos com secção transversal de 1 mm2 de área. Os espécimes foram submetidos ao teste de microtração (1,0 mm/min) e o modo de falha foi determinado utilizando um microscópio óptico (400x). Um espécime de cada dente foi imerso 24 h em uma solução de nitrato de prata 50% por peso e posteriormente imersos em solução reveladora sob luz fluorescente, por 8 horas. A quantidade de penetração foi avaliada por único examinador, cego em relação aos grupos, por meio de imagens em microscópio eletrônico de varredura em modo de elétrons retroespalhados, sendo adotado escore de 0 a 3. A concordância intraexaminador foi de 0,87. A média dos valores de resistência de união de cada material foi submetida à análise de variância de dois fatores e complementado pelo teste de Tukey. Para os dados da nanoinfiltração foram utilizados o teste de Kruskal Wallis e Mann-Whitney. O nível de significância adotado foi de 5%. A média (±desvio padrão) de cada material, em dentina sadia foi: KN100: 35,2 (±9,4); VI: 29,2 (±7,8); KME: 18,8 (±2,7); EASY: 27,12 (±2,42); SE: 18,77 (±7,23); SB: 37,32 (±3,95). Para dentina afetada: KN100: 35,8 (±6,7); VI: 24,9 (±5,7); KME: 14,5 (±0,7); EASY: 14,32 (±5,79); SE: 13,29 (±3,43); SB: 19,36 (±4,06). O tipo de falha mais freqüente independente do tipo de substrato foi coesiva para o CIVAV e adesiva para os sistemas adesivos e CIVMR. O fator substrato dentinário não influenciou significativamente a infiltração de prata na interface. Pode-se concluir que os CIVs não sofrem influência na resistência adesiva em relação ao substrato. Entretanto, os sistemas adesivos autocondicionante de passo único e condicionamento prévio são influenciados pelo substrato afetado por lesão de cárie. / The aim of this study was to evaluate the influence of sound and caries-affected dentin of primary teeth restored with different materials, regarding bond strength and nanoleakage. Seventy two primary second molars received standardized occlusal preparations were randomly assigned in two groups. One group was nominated as sound dentin [SD] (n=36), and the other was submitted to artificial caries challenge (pH cycling), called caries affected dentin [CAD] (n=36). Six teeth in each group were restored according to dental material: resin modified GIC with nanoparticles Ketac TM Nano [KN100], a resin modified GIC - Vitremer [VI], high viscosity glass ionomer cement KetacTM Molar Easy Mix [KME], one-step self-etch adhesive system AdperTM Easy One Self-Etch Adhesive [EASY], two-step self-etch adhesive system - AdperTM SE Plus [SE], total-etching adhesive system - AdperTM Single Bond 2 [SB]. The adhesive systems groups were restored with composite resin (Filtek Z250). After storage in distilled water (37ºC) for 24 hours, the teeth were sectioned in buccallingual direction and then in the mesial-distal to obtain bonded sticks (1 mm2). The specimens were subjected to microtensile test (1.0 mm/min) and the failure mode was determined using an optical microscope (400x). One dentin-material stick from each tooth was immersed in silver nitrate solution 50% weight per volume (24 h) and immersed in revealing solution under fluorescent light, for 8 hours. One examiner, blinded regarding groups, evaluated the images using scanning electron microscope adopting scores ranging from 0 to 3. The intra-examiner agreement was 0.87. The values of bond strength from each material were analyzed by two-way ANOVA and Tukey post hoc test. For the nanoleakage data, Kruskal-Wallis and Mann-Whitney tests were used, with level of significance set on 5%. The mean (and standard deviations) for each material, in sound dentin were: KN100: 35.2 (±9.4); VI: 29.2 (±7.8); KME: 18.8 (±2.7); EASY: 27.12 (±2.42); SE: 18.77 (±7.23); SB: 37.32 (±3.95). For caries-affected dentin: KN100: 35.8 (±6.7); VI: 24.9 (±5.7); KME: 14.5 (±0.7); EASY: 14.32 (±5.79); SE: 13.29 (±3.43); SB: 19.36 (±4.06). The most frequent type of failure regardless of substrate was cohesive, for KME, and adhesive, for the adhesive systems and RMGICs. Sound or caries-affected dentin did not significantly affect the infiltration of silver nitrate into the interface. It can be concluded that the bond strength of GICs are not influenced by the substrate, however, the one-step self-etch adhesive system and total-etching are influenced by caries-affected dentin.
120

Efeito antibacteriano e sucesso clínico/radiográfico da pasta de hidróxido de cálcio associada à clorexidina como medicação intracanal no tratamento de dentes decíduos humanos com polpa necrótica

Gondim, Juliana Oliveira [UNESP] 05 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-05Bitstream added on 2014-06-13T20:01:35Z : No. of bitstreams: 1 gondim_jo_dr_arafo.pdf: 969876 bytes, checksum: 1c14eda845f5f6e6b757db8af42c7462 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho teve como objetivos identificar e quantificar os microrganismos P. gingivalis e E. faecalis no interior dos canais radiculares de dentes decíduos humanos com polpa necrótica, avaliar o efeito do preparo biomecânico dos canais radiculares e da pasta de hidróxido de cálcio com clorexidina usada como curativo intracanal sobre esses microrganismos, bem como, avaliar o sucesso clínico e radiográfico da terapia endodôntica. Foram utilizados 32 dentes com polpa necrótica de 28 pacientes entre 3 e 8 anos de idade. Desses dentes, 12 apresentavam-se sem lesão (Grupo I) e 20 com lesão (Grupo II) na região de furca e/ou periapical vista radiograficamente. Após abertura coronária, foi realizada a primeira coleta microbiológica dos canais radiculares, o preparo biomecânico e a segunda coleta microbiológica. Em seguida, metade dos dentes dos grupos I e II recebeu como curativo intracanal a pasta de hidróxido de cálcio em polietilenoglicol 400 [Ca(OH)2 + PEG] (grupo controle), e a outra metade, a pasta de hidróxido de cálcio com clorexidina gel a 2% [Ca(OH)2+CLX] (grupo experimental). Os dentes foram selados provisoriamente com cimento de ionômero de vidro restaurador. Depois de 30 dias os dentes foram reabertos, o curativo intracanal foi removido e, uma terceira coleta microbiológica foi realizada. Todos os dentes tiveram os canais radiculares obturados com pasta de hidróxido de cálcio em polietilenoglicol 400 e foram restaurados. As amostras microbiológicas foram processadas usando PCR (reação em cadeia da polimerase) em tempo real e os resultados foram avaliados pelos testes de Wilcoxon e de Mann-Whitney (α=0,05). Avaliações clínica e radiográfica foram realizadas nos períodos inicial e de 1, 3 e 6 meses pós-operatório, sendo os resultados comparados pela aplicação... / This study aimed to identify the microorganisms P. gingivalis and E. faecalis in root canals of human deciduous teeth with necrotic pulp, to evaluate the effect of biomechanical preparation of root canals, to evaluate the antibacterial effect of a calcium hydroxide paste prepared with chlorhexidine against these microorganisms, and to evaluate clinical and radiographic success of the endodontic therapy. Thirty two teeth with necrotic pulp of 28 children aged between 3 and 8 years were used. Of these teeth, 12 showed no bone lesions (Group I) and 20 showed radiographic furcation/periapical bone lesions (Group II). After coronal opening and initial microbial root canal sampling, biomechanical preparation and the second microbial sampling were performed. Then, half of the teeth in groups I and II received as intracanal dressing a calcium hydroxide paste in polyethylene glycol 400 [Ca (OH)2 + PEG] (group control), and the other half received calcium hydroxide paste with 2% chlorhexidine gel [Ca (OH)2 + CHX] (experimental group). The teeth were temporarily sealed with a glass ionomer filling material. After 30 days the teeth were reopened, the intracanal dressing was removed and a third microbial sampling was performed. All the teeth had the root canals filled with a calcium hydroxide paste in polyethylene glycol 400 and the final restoration was carried. The microbial samples were processed using real time PCR (polymerase chain reaction) analysis and the results were evaluated by Wilcoxon and Mann-Whitney tests (α=0.05). Clinical and radiographic evaluations were performed at 0, 1, 3 and 6 months postoperatively and the results were compared by the Z statistical test (α=0.05). There was no significant difference between the microbiota present in primary teeth with and without furcation and/or periapical lesions. Biomechanical... (Complete abstract click electronic access below)

Page generated in 0.0502 seconds