• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 14
  • 12
  • 10
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Resistência de união ao cisalhamento na colagem de bráquetes ortodônticos metálicos a dentes artificiais de acrílico

Cumerlato, Marina Lúcia January 2013 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2013-06-18T20:39:54Z No. of bitstreams: 1 448696.pdf: 2282582 bytes, checksum: 7c398437cf626c64872877b57644c8d8 (MD5) / Made available in DSpace on 2013-06-18T20:39:54Z (GMT). No. of bitstreams: 1 448696.pdf: 2282582 bytes, checksum: 7c398437cf626c64872877b57644c8d8 (MD5) / Introdução : O objetivo deste estudo foi, através de teste in vitro, avaliar os efeitos de diferentes tratamentos de superfície e do envelhecimento de dentes artificiais de acrílico na resistência de união ao cisalhamento de bráquetes ortodônticos metálicos colados a este tipo de superfície. Métodos : Cento e noventa e dois incisivos centrais superiores de acrílico (Dentsply) foram distribuídos aleatoriamente em dois grupos conforme o envelhecimento ou não dos mesmos. O envelhecimento ocorreu através da imersão em água destilada e incubação dos dentes em estufa de cultura a 37°C durante o período de 90 dias. Cada grupo foi subdividido aleatoriamente em quatro, conforme tratamento na superfície dos dentes: sem tratamento (controle), asperização com broca diamantada, perfurações com broca diamantada, e jateamento com óxido de alumínio 50μm. O procedimento da colagem dos bráquetes deu-se igualmente em todos os grupos com resina Transbond XT (3M Unitek, Monrovia, CA, EUA). Após uma semana de estocagem em água destilada a 37°C, os corpos de prova foram levados à máquina de ensaio universal (Emic DL 2000®) e submetidos à tensão de cisalhamento, no sentido ocluso-cervical, à velocidade de 0,05mm/min. Os tipos de fratura foram classificados de acordo com o Índice de Adesivo Remanescente (IAR). Os dados foram analisados pelos testes de ANOVA, Tukey e Kruskall-Wallis. Resultados : O tratamento mecânico influenciou no aumento da resistência de união, entretanto, somente o jateamento com óxido de alumínio e as perfurações com broca promoveram valores clinicamente aceitáveis de união (p<0,05). O envelhecimento dos dentes não alterou de forma significativa a resistência de união. Ocorreu uma predominância de falhas adesivas, ou seja, entre a superfície dentária e o adesivo. Conclusões : o tratamento de superfície em dentes de acrílico aumentou a resistência de união ao contrário do envelhecimento que não influenciou na colagem de bráquetes a estes dentes. Tratamentos superfícies como jateamento com óxido de alumínio e perfuração da superfície dentária promoveram resistência de união aceitável para a colagem ortodôntica. / Introduction : The aim of this study was to evaluate, in vitro, the effects of different surface treatments and aging on the shear bond strength of metal orthodontic brackets bonded to prefabricated resin denture teeth. Methods : One hundred and ninety two upper central incisors (Dentsply) were randomly divided into two groups according to whether or not the aging of the teeth. The aging occurred by immersion in distilled water and incubation teeth at 37°C during 90 days. Each group was randomly divided into four subgroups, according to the surface treatment rendered: no treatment (control), roughening with diamond bur, drilling with diamond bur and sandblasting with aluminum oxide 50μm. Brackets were bonded equally in all groups with Transbond XT (3M Unitek, Monrovia, CA, USA). After one week of storage in distilled water at 37°C, the specimens were taken to a universal testing machine (Emic DL 2000 ®) and subjected to shear load, in an occluso-gingival direction at a crosshead speed of 0.05 mm / min. The types of fractures were classified according to the Adhesive Remnant Index (ARI). Data were analyzed by ANOVA, Tukey and Kruskal-Wallis tests. Results : The surface treatment increased the bond strength, however, only sandblasting with aluminum oxide and drilling with drill promoted clinically acceptable values for orthodontic purposes (p<0,05). The aging of the teeth did not alter significantly the bond strength. There was a predominance of adhesive failures, i.e. between the tooth surface and the adhesive. Conclusions : bonding brackets to prefabricated resin denture teeth only resist to orthodontic and chewing forces if the surface of the teeth is sandblasted with aluminum oxide or drilled with a bur to create mechanical retention, independent of aging of the teeth.
2

"Estudo do tamanho dos dentes naturais superiores e dentes artificiais de diferentes marcas comerciais" / Study of the size of the upper natural teeth and of the artificial teeth of different commercial marks

Okawa, Marina Sayuri 16 September 2005 (has links)
Neste estudo analisou-se o tamanho de dentes naturais superiores de 119 indivíduos com idade entre 20 e 30 anos. Mediu-se a largura e a altura de todos os dentes superiores em modelos de gesso, com auxílio de um paquímetro digital. Aferiu-se também o tamanho de dentes artificiais de três marcas comerciais. Essa análise permitiu a identificação do que freqüentemente ocorre na dentição natural. Concluiu-se que: aproximadamente 48% dos incisivos centrais superiores naturais possuem a largura maior que 9,0mm. Em contrapartida, somente 14,28% dos incisivos centrais superiores artificiais analisados possuíam essa dimensão. Aproximadamente 64% dos indivíduos da pesquisa possuíam o dente 14 com largura maior que 7,0mm. Nas cartelas de dentes artificiais aferidas, encontrou-se apenas um modelo com dimensão mesiodistal superior a 7,0mm. Cerca de 74% dos primeiros molares superiores naturais possuíam altura menor que 7,0mm. Somente um modelo artificial possui altura menor que 7,0mm. A adequação das dimensões dos dentes artificiais facilitaria a montagem dos dentes e traria a estética almejada ao portador de reabilitações protéticas. / In this study, the size of natural maxillary teeth of 119 individuals between 20 and 30 years old were analyzed. The width and the height of all of the upper teeth on the casts were measured with a digital caliper. The size of the artificial teeth of three commercial marks was also checked. That analysis allowed the identification of what frequently occurs in the natural dentition. The conclusion was that: approximately 48% of the width of natural maxillary central incisor was greater than 9,0mm. However, only 14,28% of the artificial central upper incisor analyzed had that dimension. Approximately 64% of the population in the research had tooth 14 with width larger than 7,0mm. In the moulds of the teeth available, was found only a model with mesiodistal dimension over 7,0mm. Around 74% of the height of natural maxillary first molars was smaller than 7,0mm. Only an artificial model had height smaller than 7,0mm. The adaptation of the dimensions by artificial teeth would facilitate the assembly of the teeth and would bring the esthetics desired for to the user of the prosthetic replacements.
3

"Estudo comparativo da largura dos dentes naturais anteriores superiores em ralação aos dentes artificiais para prótese total" / Comparative study between upper anterior natural teeth and artificial teeth for complete dentures

Kiausinis, Max Dalla 14 September 2005 (has links)
Estudou-se a largura dos dentes anteriores superiores de 121 jovens universitários brasileiros para determinar quais modelos e qual marca de dentes artificiais seriam os mais adequados para este grupo. As arcadas dentais completas foram moldadas com alginato e vazadas em gesso especial na parte oclusal e gesso pedra na base. Os dentes não apresentavam nenhum sinal de abrasões anormais, restaurações ou deformidades. A saúde periodontal era boa com mínima ou nenhuma retração gengival, inflamação ou hipertrofia. Os dentes dos modelos em gesso e os artificiais tiveram sua dimensão mesio-distal (largura) mensurada com um paquímetro digital. Não foi observada diferença significativa entre os sexos e entre as hemi-arcadas direita e esquerda com relação à largura dos dentes anteriores superiores. Das marcas analisadas nenhuma foi considerada apropriada para o grupo em questão devido ao fato de possuírem poucas opções de modelos e estes serem fabricados em tamanhos predominantemente pequenos enquanto que os dentes naturais mostraram-se predominantemente maiores (mais largos), o que nos apontou à necessidade de se adaptar ou criar modelos que sejam mais adequados à realidade brasileira. / It was studied the width of upper anterior teeth in 121 Brazilian college students intending to determine which models and brands would be more adequate to such group. The whole dental arch was molded with alginate and stone type four was poured in the oclusal surface of teeth while stone type two was poured in the left parts. Those teeth did not present abnormal abrasions, fillings or deformities. Periodont was healthy presenting little or none gengival retraction, inflamation or hipertrophy. Both stone models and artificial teeth had their mesio-distal distance (width) measured by a digital caliper rule. It was not observed significant difference between genders or right and left hemi-arches when comparing to the upper anterior teeth’s width. Considering the analyzed brands none was considered appropriate to such group because there were little options besides sizes being considered too small when compared to natural teeth, which pointed to the necessity to adapt or to create models more adequate to the Brazilian reality.
4

Resist?ncia de uni?o ao cisalhamento na colagem de br?quetes ortod?nticos met?licos a dentes artificiais de acr?lico

Cumerlato, Marina L?cia 20 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:25Z (GMT). No. of bitstreams: 1 448696.pdf: 2282582 bytes, checksum: 7c398437cf626c64872877b57644c8d8 (MD5) Previous issue date: 2013-03-20 / Introduction : The aim of this study was to evaluate, in vitro, the effects of different surface treatments and aging on the shear bond strength of metal orthodontic brackets bonded to prefabricated resin denture teeth. Methods : One hundred and ninety two upper central incisors (Dentsply) were randomly divided into two groups according to whether or not the aging of the teeth. The aging occurred by immersion in distilled water and incubation teeth at 37?C during 90 days. Each group was randomly divided into four subgroups, according to the surface treatment rendered: no treatment (control), roughening with diamond bur, drilling with diamond bur and sandblasting with aluminum oxide 50&#956;m. Brackets were bonded equally in all groups with Transbond XT (3M Unitek, Monrovia, CA, USA). After one week of storage in distilled water at 37?C, the specimens were taken to a universal testing machine (Emic DL 2000 ?) and subjected to shear load, in an occluso-gingival direction at a crosshead speed of 0.05 mm / min. The types of fractures were classified according to the Adhesive Remnant Index (ARI). Data were analyzed by ANOVA, Tukey and Kruskal-Wallis tests. Results : The surface treatment increased the bond strength, however, only sandblasting with aluminum oxide and drilling with drill promoted clinically acceptable values for orthodontic purposes (p<0,05). The aging of the teeth did not alter significantly the bond strength. There was a predominance of adhesive failures, i.e. between the tooth surface and the adhesive. Conclusions : bonding brackets to prefabricated resin denture teeth only resist to orthodontic and chewing forces if the surface of the teeth is sandblasted with aluminum oxide or drilled with a bur to create mechanical retention, independent of aging of the teeth. / Introdu??o : O objetivo deste estudo foi, atrav?s de teste in vitro, avaliar os efeitos de diferentes tratamentos de superf?cie e do envelhecimento de dentes artificiais de acr?lico na resist?ncia de uni?o ao cisalhamento de br?quetes ortod?nticos met?licos colados a este tipo de superf?cie. M?todos : Cento e noventa e dois incisivos centrais superiores de acr?lico (Dentsply) foram distribu?dos aleatoriamente em dois grupos conforme o envelhecimento ou n?o dos mesmos. O envelhecimento ocorreu atrav?s da imers?o em ?gua destilada e incuba??o dos dentes em estufa de cultura a 37?C durante o per?odo de 90 dias. Cada grupo foi subdividido aleatoriamente em quatro, conforme tratamento na superf?cie dos dentes: sem tratamento (controle), asperiza??o com broca diamantada, perfura??es com broca diamantada, e jateamento com ?xido de alum?nio 50&#956;m. O procedimento da colagem dos br?quetes deu-se igualmente em todos os grupos com resina Transbond XT (3M Unitek, Monrovia, CA, EUA). Ap?s uma semana de estocagem em ?gua destilada a 37?C, os corpos de prova foram levados ? m?quina de ensaio universal (Emic DL 2000?) e submetidos ? tens?o de cisalhamento, no sentido ocluso-cervical, ? velocidade de 0,05mm/min. Os tipos de fratura foram classificados de acordo com o ?ndice de Adesivo Remanescente (IAR). Os dados foram analisados pelos testes de ANOVA, Tukey e Kruskall-Wallis. Resultados : O tratamento mec?nico influenciou no aumento da resist?ncia de uni?o, entretanto, somente o jateamento com ?xido de alum?nio e as perfura??es com broca promoveram valores clinicamente aceit?veis de uni?o (p<0,05). O envelhecimento dos dentes n?o alterou de forma significativa a resist?ncia de uni?o. Ocorreu uma predomin?ncia de falhas adesivas, ou seja, entre a superf?cie dent?ria e o adesivo. Conclus?es : o tratamento de superf?cie em dentes de acr?lico aumentou a resist?ncia de uni?o ao contr?rio do envelhecimento que n?o influenciou na colagem de br?quetes a estes dentes. Tratamentos superf?cies como jateamento com ?xido de alum?nio e perfura??o da superf?cie dent?ria promoveram resist?ncia de uni?o aceit?vel para a colagem ortod?ntica.
5

Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.

Pâmela Carbone Mello 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91&micro;m e M=1,78±0,42&micro;m). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de &Delta;E foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de &Delta;E>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (&Delta;E=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91&micro;m and M=1,78±0,42&micro;m). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The &Delta;E values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of &Delta;E (&Delta;E>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (&Delta;E=2.73±0.96) and the Biolux group presented to smallest color variation (&Delta;E=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
6

Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.

Mello, Pâmela Carbone 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91&micro;m e M=1,78±0,42&micro;m). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de &Delta;E foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de &Delta;E>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (&Delta;E=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91&micro;m and M=1,78±0,42&micro;m). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The &Delta;E values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of &Delta;E (&Delta;E>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (&Delta;E=2.73±0.96) and the Biolux group presented to smallest color variation (&Delta;E=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
7

"Estudo do tamanho dos dentes naturais superiores e dentes artificiais de diferentes marcas comerciais" / Study of the size of the upper natural teeth and of the artificial teeth of different commercial marks

Marina Sayuri Okawa 16 September 2005 (has links)
Neste estudo analisou-se o tamanho de dentes naturais superiores de 119 indivíduos com idade entre 20 e 30 anos. Mediu-se a largura e a altura de todos os dentes superiores em modelos de gesso, com auxílio de um paquímetro digital. Aferiu-se também o tamanho de dentes artificiais de três marcas comerciais. Essa análise permitiu a identificação do que freqüentemente ocorre na dentição natural. Concluiu-se que: aproximadamente 48% dos incisivos centrais superiores naturais possuem a largura maior que 9,0mm. Em contrapartida, somente 14,28% dos incisivos centrais superiores artificiais analisados possuíam essa dimensão. Aproximadamente 64% dos indivíduos da pesquisa possuíam o dente 14 com largura maior que 7,0mm. Nas cartelas de dentes artificiais aferidas, encontrou-se apenas um modelo com dimensão mesiodistal superior a 7,0mm. Cerca de 74% dos primeiros molares superiores naturais possuíam altura menor que 7,0mm. Somente um modelo artificial possui altura menor que 7,0mm. A adequação das dimensões dos dentes artificiais facilitaria a montagem dos dentes e traria a estética almejada ao portador de reabilitações protéticas. / In this study, the size of natural maxillary teeth of 119 individuals between 20 and 30 years old were analyzed. The width and the height of all of the upper teeth on the casts were measured with a digital caliper. The size of the artificial teeth of three commercial marks was also checked. That analysis allowed the identification of what frequently occurs in the natural dentition. The conclusion was that: approximately 48% of the width of natural maxillary central incisor was greater than 9,0mm. However, only 14,28% of the artificial central upper incisor analyzed had that dimension. Approximately 64% of the population in the research had tooth 14 with width larger than 7,0mm. In the moulds of the teeth available, was found only a model with mesiodistal dimension over 7,0mm. Around 74% of the height of natural maxillary first molars was smaller than 7,0mm. Only an artificial model had height smaller than 7,0mm. The adaptation of the dimensions by artificial teeth would facilitate the assembly of the teeth and would bring the esthetics desired for to the user of the prosthetic replacements.
8

"Estudo comparativo da largura dos dentes naturais anteriores superiores em ralação aos dentes artificiais para prótese total" / Comparative study between upper anterior natural teeth and artificial teeth for complete dentures

Max Dalla Kiausinis 14 September 2005 (has links)
Estudou-se a largura dos dentes anteriores superiores de 121 jovens universitários brasileiros para determinar quais modelos e qual marca de dentes artificiais seriam os mais adequados para este grupo. As arcadas dentais completas foram moldadas com alginato e vazadas em gesso especial na parte oclusal e gesso pedra na base. Os dentes não apresentavam nenhum sinal de abrasões anormais, restaurações ou deformidades. A saúde periodontal era boa com mínima ou nenhuma retração gengival, inflamação ou hipertrofia. Os dentes dos modelos em gesso e os artificiais tiveram sua dimensão mesio-distal (largura) mensurada com um paquímetro digital. Não foi observada diferença significativa entre os sexos e entre as hemi-arcadas direita e esquerda com relação à largura dos dentes anteriores superiores. Das marcas analisadas nenhuma foi considerada apropriada para o grupo em questão devido ao fato de possuírem poucas opções de modelos e estes serem fabricados em tamanhos predominantemente pequenos enquanto que os dentes naturais mostraram-se predominantemente maiores (mais largos), o que nos apontou à necessidade de se adaptar ou criar modelos que sejam mais adequados à realidade brasileira. / It was studied the width of upper anterior teeth in 121 Brazilian college students intending to determine which models and brands would be more adequate to such group. The whole dental arch was molded with alginate and stone type four was poured in the oclusal surface of teeth while stone type two was poured in the left parts. Those teeth did not present abnormal abrasions, fillings or deformities. Periodont was healthy presenting little or none gengival retraction, inflamation or hipertrophy. Both stone models and artificial teeth had their mesio-distal distance (width) measured by a digital caliper rule. It was not observed significant difference between genders or right and left hemi-arches when comparing to the upper anterior teeth’s width. Considering the analyzed brands none was considered appropriate to such group because there were little options besides sizes being considered too small when compared to natural teeth, which pointed to the necessity to adapt or to create models more adequate to the Brazilian reality.
9

Avaliação da área de contato dos dentes artificiais em função da forma oclusal e da forma das arcadas na posição de máxima intercuspidação e nos movimentos excursivos / Measurement of occlusal area in prosthetic teeth according to tooth form, arch form and during maximum voluntary clenching and excursive movements

Mazini Neto, Paulo 08 August 2007 (has links)
Nesta pesquisa, foi analisada a área dos contatos oclusais, em posição de máxima intercuspidação e nos movimentos excursivos de protrusão e lateralidades direita e esquerda. Para tanto, foram utilizados dentes artificiais anatômicos e funcionais, nacionais e importados, montados em arcadas de formas triangular, quadrada e oval. Após o devido ajuste oclusal e, a partir das imagens digitalizadas das próteses em cera, foi realizada a mensuração das áreas demarcadas pelo papel carbono, empregando-se o software Leica Qwin&reg; 550. Os resultados, em milímetros quadrados, foram submetidos à análise estatística (ANOVA e Teste de Tukey). A partir das relações estabelecidas entre os fatores, pode-se concluir que, tanto para o modelo superior quanto para o modelo inferior, as áreas totais em MIC foram maiores que as áreas totais em protrusão. Ainda em protrusão, os segmentos posterior direito, anterior e posterior esquerdo apresentaram áreas iguais. Nos movimentos de lateralidade direita e esquerda, as áreas totais foram menores ou iguais às áreas totais obtidas em MIC. Nas lateralidades, as áreas no lado de trabalho foram maiores que as áreas no lado de balanceio. Na lateralidade direita, a área no lado de trabalho foi maior que a área direita do registro obtido em MIC. Na lateralidade esquerda, a área no lado de trabalho foi maior que a área do segmento esquerdo do registro em MIC. Na lateralidade direita, a área no lado de balanceio foi menor que a área do segmento esquerdo do registro em MIC. Na lateralidade esquerda, a área no lado de balanceio foi menor que a área do segmento direito do registro em MIC. / This study regards the measurement of occlusal area of prosthetic arches, all assembled in triangular, squared and oval arch forms, with functional prosthetic teeth from different manufacturers; occlusal area was measured during maximum voluntary clenching (MVC), protrusive and laterotrusive (right and left) movements. Following arch assembly and occlusal adjustment, occlusal contacts for MVC and eccentric movement were marked by carbon paper, and occlusal areas were measured by means of analysis of standardized digital images and appropriate software (Leica Qwin&reg; - 550). Occlusal areas were measured in square millimiters, and resulting values underwent statistical tests (ANOVA and Tukey). Statistical results showed that, for both upper and lower arches, occlusal areas during MVC were greater than during protrusion; also during protrusion, buccal tooth segments, both right and left, showed similar areas. During right and left laterotrusion, occlusal areas were smaller in comparison to MVC, and working sides presented larger areas than balancing sides. During laterotrusion to the right side, occlusal areas measured at the working side were larger than during MVC (right side), and same was observed for the left side during laterotrusion to the left. During laterotrusion to the right side, occlusal areas measured at the balancing side were smaller than during MVC (left side), and similar differences were observed during laterotrusion to the left side.
10

Técnica de replicação de raízes dentárias em resina composta fotopolimerizável a partir de molde de resina acrílica autopolimerizável / Root tooth replication technique in photo polymerized composite resin made by means of an acrylic resin mold by self polymerized resin

Camargo, Sergio Luiz da Silveira 08 February 2011 (has links)
Pelas fraturas que sofrem os dentes caninos, torna-se necessário tratá-los endodonticamente, e repará-los proteticamente. Porém, novas fraturas coronais, com ou sem perda de coroa metálica podem se repetir. Muitas técnicas restauradoras priorizam os dentes com maior percentual de porção coronal, porque a extensa área de coroa remanescente assegura execução facilitada, favorecendo a recuperação do elemento dental e garantindo sucesso do assentamento da peça metálica. As pesquisas realizadas para se conseguir novos tratamentos utilizam dentes naturais para simular a realidade. Não há banco de dentes rotineiro na Odontologia Veterinária. O uso de dentes naturais de animais encontra restrições por conta da grande diversidade de raças e de porte entre cães, consequentemente no tamanho e na anatomia dos dentes. Existe ainda a carência de disponibilidade de amostras naturais na quantidade necessária para desenvolver tais estudos. O material artificial capaz de substituir os dentes naturais pode estar nas resinas compostas fotopolimerizáveis que apresentam propriedades mecânicas semelhantes às da dentina. Para se replicar o dente natural em resina composta, foi criado um molde em resina acrílica transparente. A literatura deste assunto é escassa ou mesmo inexiste. Com a construção de dentes artificiais muitas pesquisas podem ser realizadas, pois as amostras dentárias serão padronizadas de acordo com a necessidade de cada estudo a ser desenvolvido. Neste trabalho objetivou-se reproduzir quarenta dentes artificiais (réplicas) para demonstrar a possibilidade do padrão de cópia a partir do uso de um molde de resina acrílica. Os resultados mostraram que as réplicas foram similares ao dente natural. / Due to the fractures that canine teeth suffer, it is necessary to treat these teeth endodonticaly and restore them prosthetically (with pin, post core and metallic crown) in its coronal portion. However a new coronal fracture can happen with or without loss of the prosthodontic work. Many of the techniques aim at the teeth with larger extension of remaining area of crown, which favors the crown preparation and fixation of the prosthesis. Many researches use natural teeth to simulate the real conditions. In Veterinary Dentistry there is no routine bank of teeth. However there is a variety of dog breeds with different sizes, as well as a great variety in extension of the teeth. Additionally there is large numbers of natural teeth available enough for use in all researches. The material that can substitute the natural teeth seems to be the photo polymerized composite resin, which has similar mechanical properties to dentin. To replicate the natural teeth in composite resin, a mold was created in acrylic transparent resin. Literature of this subject is spares or inexistent. With artificial replication of teeth many researches can be achieved, once the samples of teeth can be standardized, according to which study. This project aimed to reproduce 40 replicas to demonstrate the possibility of copy from a transparent acrylic mold. Results showed that the replicas were similar to the natural tooth.

Page generated in 0.0691 seconds