• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 179
  • 12
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 204
  • 204
  • 193
  • 178
  • 160
  • 75
  • 69
  • 68
  • 63
  • 52
  • 49
  • 39
  • 38
  • 34
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo in vitro da influência da contaminação com Streptococcus mutans e da descontaminação com digluconato de clorexidina 2% na resistência de união de sistemas adesivos à dentina humana / In vitro study of the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on bond strength of adhesive systems to human dentin

Bengtson, Camilla Regina Galvao 21 June 2007 (has links)
O objetivo desse trabalho foi avaliar, in vitro, a influência da contaminação com Streptococcus mutans e da desinfecção com solução de digluconato de clorexidina 2% na adesão de dois sistemas adesivos (um sistema adesivo com condicionamento ácido prévio e um sistema adesivo autocondicionante) à dentina de molares humanos. Para o estudo, foram utilizados 80 terceiros molares humanos hígidos, com a face oclusal lixada até a exposição de uma superfície plana de dentina. Os dentes foram divididos aleatoriamente em 8 grupos (n=10) de acordo com o sistema adesivo utilizado e tratamento superficial realizado: G1 ? Controle Single Bond 2 (SB); G2 ? Controle Clearfil SE Bond (SE); G3 ? Desinfecção com clorexidina SB; G4 ? Desinfecção com clorexidina SE; G5 ? Contaminação com Streptococcus mutans SB; G6 ? Contaminação com Streptococcus mutans SE; G7 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SB e G8 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SE. Corpos de prova em resina composta foram confeccionados nas superfícies tratadas e os dentes foram armazenados em água destilada à 37ºC por 24 horas. As amostras foram seccionadas verticalmente obtendo-se espécimes com área de secção transversal de aproximadamente 0,8mm2, que foram tracionados a velocidade de 0,5mm/min em máquina de ensaios universal. Cinco espécimes de cada grupo tiveram a interface adesiva analisada em microscopia eletrônica de varredura (MEV). Os resultados de resistência de união foram analisados usando os testes estatísticos ANOVA e Tukey (p<0,05). Os modos de fraturas foram avaliados por meio de lupa esteroscópica (25X). Discos de dentina foram obtidos de 6 dentes adicionais, para observação em MEV das superfícies submetidos aos mesmos tratamentos realizados para o teste de microtração. Não foram encontradas diferenças estatísticas entre os grupos controles (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), o tratados com clorexidina (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) e os grupos que foram submetidos à contaminação com Streptococcus mutans e descontaminação com clorexidina (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). Os grupos submetidos à contaminação com Streptococcus mutans que não foram descontaminados antes da aplicação dos sistemas adesivos tiveram resultados significantemente menores que os grupos estéreis e descontaminados (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). O sistema adesivo Clearfil SE Bond apresentou valores de resistência de união significantemente maiores que o sistema adesivo Single Bond 2, independente do tratamento da superficial dentina. Pôde-se concluir que a contaminação in vitro com Streptococcus mutans comprometeu a adesão dos dois sistemas adesivos e a solução de digluconato de clorexidina 2% foi capaz de eliminar a contaminação, restabelecendo os valores de resistência de união obtidos com o substrato estéril. / The purpose of this study was to evaluate, in vitro, the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on the bond strength of two adhesive systems (an etch-and-rinse system and a self-etch system) to human dentin molars. Flat dentinal surfaces were prepared in 80 extracted human third molars. Teeth were randomly divided into 8 groups (n=10) according to the adhesive system and the dentin superficial treatment: G1 ? Single Bond 2 (SB) control; G2 ? Clearfil SE Bond (SE) control; G3 ? Desinfection with chlorhexidine SB; G4 ? Desinfection with chlorhexidine SE; G5 ? Contamination with Streptococcus mutans SB; G6 ? Contamination with Streptococcus mutans SE; G7 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SB e G8 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SE. Composite resin blocks were built up over treated surfaces, and teeth were then stored in water at 37 degrees C for 24 h. Samples were vertically sectioned, obtaining specimens with 0.8mm2 cross-sectional area. Specimens were stressed in tension at 0.5 mm/min crosshead speed. Five specimens of which group were observed under SEM. Bond strength results were evaluated using ANOVA and Tukey tests(p<0.05). The modes of failures were verified using optical microscope (25X). Dentin disks were obtained from 6 additional teeth treated in the same manner for observation under SEM. No statistically significant differences of bond strength values were found between controls groups (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), groups treated with chlorhexidine (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) and groups contaminated with Streptococcus mutans (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). The groups contaminated with Stretococcus mutans that were not desinfected before the adhesive systems application presented significantly lesser results than sterile or desinfected groups (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). Clearfil SE Bond presented significant high bond strenght values than Single Bond 2, independent of dentin superficial treatment. It was concluded that the contamination in vitro with Streptococcus mutans reduced bond strength of the two adhesives systems and 2% chlorhexidine digluconate solution eliminated the contamination, reestablishing the bond strength values gotten with sterile substrates.
32

Avaliação da resistência de união de cimentos resinosos, em função de diferentes protocolos, para cimentação de restauração cerâmica em dentina / Evaluation of resin cement bond strength in light of different protocols for the cementation of ceramic restorations in dentin

Oliveira, Damaris Amazonas de 23 May 2013 (has links)
Este estudo avalia a resistência de união à microtração de dois cimentos resinosos (RelyXTM U200 - 3M/ESPE e RelyXTM ARC - 3M/ESPE), na fixação de restauração cerâmica, em função do tipo de tratamento ao substrato dentinário: G1, sem tratamento (cimento autoadesivo RelyX U200); G2, sistema adesivo autocondicionante de dois passos (ClearfilTM SE Bond, Kuraray /RelyXTM ARC); e G3, sistema adesivo convencional de três passos (AdperTM ScotchbondTM Multi- Purpose, 3M/ESPE /RelyXTM ARC). Trinta dentes bovinos foram selecionados, limpos e armazenados em solução neutra de timol a 0,1% a 37oC, sendo divididos aleatoriamente em três grupos experimentais (n=10). O esmalte da face vestibular foi desgastado para expor a superfície dentinária com área de 8 mm x 8 mm e submetido, em seguida, a planificação com lixas de carbeto de silício no 180, 320 e 600. Trinta blocos cerâmicos de dissilicato de lítio, IPS e-max - Ivoclar Vivadent, medindo 8 mm x 8 mm x 2 mm, foram confeccionados e suas superfícies de cimentação jateadas com partículas de óxido de alumínio (50&#x3BC;m). Previamente à cimentação, todos os blocos cerâmicos tiveram suas superfícies internas condicionadas com ácido fluorídrico e foram aplicados agentes silano. Os tratamentos em dentina e os procedimentos de cimentação seguiram as normas dos fabricantes correspondentes para cada grupo. Decorridas 24 horas da cimentação, os conjuntos dente/cimento/cerâmica foram seccionados em forma de vigas, com área aproximada de 1 mm2, adaptados à máquina universal de ensaios (INSTRON) para realização do teste de microtração, utilizando-se a célula de carga de 500N com velocidade de 0,5 mm/minuto. Os valores médios de resistência à microtração (MPa) encontrados foram: G1 (16,16 ± 7,16), G2 (27,92 ± 6,17) e G3 (25,06 ± 6,09). Os dados foram submetidos à análise de variância e ao teste de Tukey em nível de significância de 5%. O cimento resinoso autoadesivo RelyXTM U200 apresentou menor potencial de resistência de união com diferença estatística significante, quando comparado ao cimento resinoso convencional RelyXTM ARC e tratamento prévio com os adesivos convencional de três passos e autocondicionante de dois passos. Entretanto, a associação do cimento RelyXTM ARC tanto ao sistema adesivo convencional quanto ao acondicionante apresentou valores médios similares de resistência de união aos substratos dentinário e cerâmico. Dentre os tipos de fratura, após o teste de microtração, o cimento RelyXTM U200 demonstrou maior ocorrência de falhas do tipo adesiva em dentina (AD), com menor interação adesiva junto à dentina. A associação do sistema adesivo convencional ao cimento resinoso convencional evidenciou menor ocorrência de fraturas AD e maior ocorrência junto à cerâmica, quando comparada à associação do sistema adesivo autocondicionante ao cimento resinoso convencional, apesar de os resultados de resistência de união demonstrarem similaridade de valores e estatística. / This study evaluates the microtensile bond strength of two resin cements (RelyXTM U200 - 3M/ESPE and RelyXTM ARC - 3M/ESPE), in the retention of ceramic restorations according to the treatment type of the dentin substrate; G1: no treatment (RelyX U200 self-adhesive cement); G2: two-step self-etch adhesives (ClearfilTM SE Bond, Kuraray /RelyXTM ARC); and G3: three-step etch and rinse adhesives (AdperTM ScotchbondTM Multi-Purpose, 3M/ESPE /RelyXTM ARC). Thirty bovine teeth were selected, cleaned and stored in a neutral 0,1% thymol solution at 37oC, divided randomly into three experimental groups (n=10). The facial surface enamel was scaled in order to expose an area of 8mm x 8mm of the dentin surface, and subsequently planed with no 180, 320 and 600 silico n carbide sandpaper. Thirty lithium disilicate ceramic blocks, IPS e-max Ivoclar Vivadent, measuring 8mm x 8mm x 2mm were made and their surfaces sandblasted with aluminum oxide particles (50&#x3BC;m). Before cementation, the internal surfaces of all the ceramic blocks were conditioned with hydrofluoric acid and silanized. The dentin treatments and the cementation procedures followed the manufacturers norms for each group. Twentyfour hours after cementation, the tooth/cement/ceramic blocks were sectioned into beam-like structures, each with an approximate area of 1mm2, adapted to the universal testing machine (INSTRON) in order to test microtensile strength, with the load cell set at 500N, at a speed of 0.5mm/min. The mean values found for microtensile strength (MPa) were: G1 (16,16 ± 7,16), G2 (27,92 ± 6,17) and G3 (25,06 ± 6,09). The data were submitted to analysis of variance and to Tukeys test, with a 5% significance level. The self-adhesive resin cement RelyXTM U200 presented the lowest potential bond strength, with a statistically significant difference when compared to the conventional resin cement RelyXTM ARC and prior treatment with three-step etch and rinse adhesives and two-step self-etch adhesives. However the association of the RelyXTM ARC cement, both with the conventional adhesive system and with the self-etch adhesives produced similar mean values for bond strength in the dentin and ceramic substrates. Among the types of fracture, following the test for microtensile strength, the RelyXTM U200 cement presented the highest incidence of faults of the dentin adhesive (DA) type, and the lowest adhesive interaction with the dentin. The association of the conventional adhesive system with conventional resin cement presented a lower incidence of DA fractures and a higher incidence along the ceramics, when compared to the association of the self-etch adhesive system and conventional resin cement, despite the similarity in the numbers and statistics of the bond strength results.
33

Avaliação do grau de sorção, solubilidade e taxa de conversão de sistemas adesivos irradiados com laser de diodo / Evaluation of water sorption/solubility and conversion degree of the adhesive systems irradiated with diode laser

Brianezzi, Leticia Ferreira de Freitas 03 March 2015 (has links)
O LASER tem sido utilizado previamente a polimerização de sistemas adesivos em dentina como uma estratégia para melhorar as suas propriedades. O objetivo deste estudo foi investigar o efeito do LASER de diodo na sorção (SB), solubilidade e grau de conversão das principais categorias de sistemas adesivos. Quatro sistemas adesivos foram testados: convencional de 3 passos (Adper&#x2122; Scotchbond&#x2122; Multi-Purpose-MP), convencional de 2 passos (Adper&#x2122; Single Bond 2-SB), autocondicionante de 2 passos (Clearfil&#x2122; SE Bond-SE) e o sistema universal (Adper&#x2122; Single Bond Universal-SU). O adesivo fluido foi dispensado numa matriz de teflon (6.0 x 6.0 x 1 m),irradiado com laser de diodo com 970 nm e polimerizado com luz LED. Para o teste de sorção e solubilidade foram preparados espécimes em uma matriz de teflon quadrada (n=10): MP, SB, SE e SU (sem irradiação) e MP-L, SB-L, SE-L e SU-L (grupos com irradiação). Essa mensuração foi monitorando a mudança de massa depois dos ciclos de armazenamento de desidratação/ água. Para o grau de conversão, espécimes similares eram preparados e divididos 8 grupos iguais (n=5), utilizando a espectroscopia infravermelho transformada de Fourrrier (FTIR) com reflectância total atenuada (ATR). Cada espécime era comprimido contra o cristal do ATR (diamante/ZnSe) com um pressão micrométrica. As amostras não polimerizadas (&#x2248;3.0&#x3BC;L, n=5) de cada adesivo era escaneada para calcular o grau de conversão. Para sorção (&#x3BC;g/mm3) houve diferença estatisticamente significante para ambos os fatores (p<0.05) sem interação entre eles SB> SU> MP> SE. Para a solubilidade (&#x3BC;g/mm3), somente o fator adesivo foi significante (p<0.05): SB>SU>MP=SE. A irradiação do LASER antes da polimerização aumentou o grau de conversão dos sistemas adesivos SBL> MP-L> SE-L> MP> SB> SE> SU-L> SU. A irradiação aumentou a sorção, mas não afetou a solubilidade dos sistemas adesivos. Além disso, a irradiação com LASER de diodo melhorou o grau de conversão de três sistemas adesivos testados. / Laser irradiation has been used over the dentin bonding systems (DBS) prior to polymerization as a strategy to improve their properties. The aim of this study was to investigate the effect of diode laser on water sorption (WS), solubility (WSB) and conversion degree (DC) of main categories of DBS. Four bonding agents were tested: 3-step total-etch (Adper&#x2122; Scotchbond&#x2122; Multi-Purpose-MP), 2-step total-etch (Adper&#x2122; Single Bond 2-SB), 2-step self-etch Clearfil&#x2122; SE Bond-SE) and universal system (Adper&#x2122; Single Bond Universal-SU). The fluid DBSs were dispensed into Teflon molds (6.0 x 6.0 x 1mm), irradiated with a 970 nm diode laser and then polymerized with a LED curing unit. For WS/WSB tests, square-shaped DBS were prepared (n=10): MP, SB, SE and SU (control groups/ no laser irradiation) and MP-L, SB-L, SE-L and SU-L (laser irradiated groups). WS/WSB were measured by monitoring the mass changes after dehydration/water storage cycles. For DC tests, similar square-shaped specimens were prepared and assigned into eight similar groups (n=5), using Fourier transform infrared spectroscopy (FT-IR) with attenuated total reflectance (ATR). Each cured specimen was compressed against the ATR crystal (diamond/ZnSe) with a micrometric, low-pressure clamp. Uncured resin samples (&#x2248;3.0&#x3BC;L, n=5) of each adhesive were also scanned for DC calculation. For WS (&#x3BC;g/mm3), both factors were statistically significant (p<0.05), without interaction between them SB>SU>MP>SE. For WSB (&#x3BC;g/mm3), only DBS was a significant factor (p<0.05): SB>SU>MP=SE. Laser irradiation immediately before photopolymerization has increased the DC (%) of the tested adhesives: SB-L> MPL> SE-L> MP> SB> SE> SU-L> SU. Irradiation with diode laser improved the conversion degree of all tested dentin bonding systems. Furthermore the diode laser increased the sorption, but did not affect their water solubility.
34

Influência da solução de clorexidina a 2% na resistência adesiva de pinos de fibra de vidro em raízes bovinas: acompanhamento imediato, 6 meses e 1 ano / 2% chlorhexidine influence on fiber posts bond strength to bovine roots: immediate, 6-month and 1-year-aging

Silva, Luciana Mendonça da 04 July 2013 (has links)
Este trabalho teve como objetivo avaliar a influência da solução de clorexidina a 2% na resistência adesiva de pinos de fibra de vidro cimentados com cimento resinoso convencional utilizando três diferentes sistemas adesivos (2 convencionais e 1 autocondicionante), no período de 7 dias, 6 meses e 1 ano. Foram selecionadas 180 raízes bovinas, que foram tratadas endodonticamente e divididas em 6 grupos (n=30): MP, sistema adesivo (SA) convencional de 3 passos (ScotchBond Multi Uso); SB, SA convencional de 2 passos (Single Bond); SE, SA autocondicionante de 2 passos (Clearfil SE Bond); MP-CHX, SB-CHX e SE-CHX, com aplicação da clorexidina (CHX). Em todos os grupos, o pino de fibra de vidro Exacto foi cimentado com cimento resinoso dual RelyX ARC. Cada grupo foi dividido em 3, de acordo com o período experimental, 7 dias, 6 meses e 1 ano (n=10). Após a obtenção de fatias com 1mm de espessura, os espécimes foram submetidos ao teste de push-out (100kg, 0,5mm/min). Os tipos de falhas foram analisados em microscópio ótico de luz (40x) e classificados em: adesiva cimento/dentina; adesiva cimento/pino; coesiva em dentina ou cimento, e mista. Os valores, convertidos em MPa, foram analisados pelo teste ANOVA a 4 critérios e teste de Tukey para comparação das médias, com nível de significância de 5%. Não houve diferença estatística com o uso da CHX para os SAs convencionais testados, nos períodos de 7 dias, 6 meses e 1 ano (p>0,05). Dentre os SA, o MP foi o que se manteve constante com ou sem CHX (p>0,05). Houve diminuição de resistência adesiva no terço cervical, em 1 ano, e no terço apical em 7 dias do SE-CHX (p<0,05). Pode-se concluir que o uso da CHX pareceu não interferir na resistência adesiva dos SAs testados, exceto para o SA autocondicionante, em 7 dias e 1 ano. / The aim of this work was to evaluate the 2% chlorhexidine influence on fiber posts bond strength luted with a resin cement, with three different dentin bonding systems (2 etch-and-rinse and 1 self-etching), with 7-day, 6-month and one-year-aging. One hundred and eighty bovine roots were endodontically treated and randomly assigned to 6 groups (n=30): MP, three-step etch-and-rinse dentin bonding system (DBS) (ScotchBond Multi Uso); SB, two-step etch-and-rinse DBS (Single Bond); SE, twostep self-etching DBS (Clearfil SE Bond); MP-CHX, SB-CHX and SE-CHX, with chlorhexidine (CHX) application. Exacto fiber posts were luted with dual cure resin cement RelyX ARC in all groups. Each group was divided in three, according to aging (n=10). After obtainning 1mm-thick slices, push-out test was carried out (100kg, 0,5mm/min). Failure modes were assessed under light microscopy (40x) and classified in: adhesive to dentin; adhesive to post; cohesive in dentin or cement, and mixed failure. Values were converted to MPa and analyzed by 4-way ANOVA and Tukeys test for multiple comparisons, at 5% significance level. There was no difference with the use of CHX for tested etch-and-rinse DBSs, after 7-day, 6-month and one-year-aging (p>0,05). Among DBSs, MP presented constant values (p>0,05). SE-CHX presented significant lower bond strength values on the cervical third, at one year, and apical third at 7 days (p<0,05). It can be concluded that CHX use seemed not to interfere bond strength values of all materials tested, except for the self-etch DBS, after 7 days and one year-aging.
35

Efeito da solução de clorexidina a 2% na adesão de um sistema restaurador adesivo à dentina previamente erodida com refrigerante tipo cola regular e light / Effect of 2% chlorhexidine solution on adhesive bond strength to eroded dentin by regular and light cola drinks

Casas Apayco, Leslie Caroll 28 June 2013 (has links)
Os refrigerantes são potentes agentes erosivos que podem provocar perda de estrutura dentária e requerer o tratamento restaurador adesivo, dependendo do grau de comprometimento. Pelas diferentes propriedades apresentadas, estas bebidas podem afetar a adesão à dentina de diferentes formas. Este estudo teve como objetivo avaliar a resistência de união (RU) em dentina erodida tratada com solução de clorexidina a 2%. Sessenta terceiros molares tiveram a superfície dentinária do terço oclusal exposta e foram distribuídos em 3 grupos, de acordo com o protocolo erosivo: controle, sem desafio (C), desafio erosivo com Coca-Cola (CC) e desafio erosivo com Coca-Cola Light (CL). As ciclagens erosivas foram por ciclos de 5-min de imersão 3x/dia durante 5 dias. Em seguida, metade dos dentes foi tratado com solução de clorexidina a 2% (1,5ul) e o restante com água deioinizada (1,5ul) e o processo adesivo realizado com Adper Single Bond 2® e resina composta Filtek Z350®. Os espécimes foram mantidos em estufa a 37oC por 24 horas. Após esse período, todos os espécimes foram seccionados em palitos (0,80mm2 a 1mm2). Um terço dos palitos obtidos de cada grupo foi testado imediatamente (I-24 h) pelo teste de microtração. Os espécimes remanescentes foram envelhecidos em saliva artificial por 6 meses (6m) e 1 ano (1a) antes do teste. Os dados obtidos da microtração foram analisados por meio dos testes de ANOVA a três critérios e Tukey (p<0,05). O modo de fratura foi analisado e classificado em adesivo, misto e coesivo em dentina ou resina composta. Simultaneamente, uma fatia (mesiodistal) de cada espécime foi analisado por microscopia confocal para análise da interface resina/dentina e formação de tag nos tempos de envelhecimento. Os valores médios de resistência adesiva (MPa ± dp; 24 horas/6 meses /1 ano) foram: C(38,57 ± 15,36/26,67 ± 19,37/12,21 ± 11,24); C-Chx2%(41,93 ± 9,97/31,12 ± 17,02/11,86 ± 10,4); CC(21,80 ± 7,09/8,33 ± 10,71/4,70 ± 9,04); CC-Chx2%(19,85 ± 7,87/24,32 ± 11,7/6,19 ± 12,37); CL (22,70 ± 9,63/10,25 ± 15,6/4,93 ± 5,54); CL-Chx 2% (22,40 ± 7,34/20,94 ± 14,68/16,05 ± 13,91). A resistência de união à dentina erodida foi significativamente inferior ao do grupo controle, independentemente do tempo de armazenagem dos espécimes. Tanto a dentina normal e erodida, apresentaram redução dos valores de resistência de união ao longo do tempo. Apesar de os espécimes tratados com solução de clorexidina a 2% manterem os valores de resistência de união por 6 meses, eles reduziram após 1 ano. De acordo com as imagens por microscopia confocal, não houve diferenças observadas na qualidade geral da camada híbrida e formação de tags entre os grupos. A solução de digluconato de clorexidina a 2% pode ser uma alternativa para manter a estabilidade da interface de união adesiva ate os 6 meses. A resistência de união mais estável à dentina erodida por Coca-Cola Light comparada à dentina erodida por Coca-Cola ao longo do tempo, sugere a implicação de suas propriedades na adesão. / Soft drinks are potent erosive agents, which can provoke loss of dental structure and require adhesive restorative treatment, depending on the compromising level. Due to the different properties, these beverages can affect bonding to dentin in different manners. The aim of this study was to evaluate the bond strength (BS) to eroded dentin treated with 2% chlorhexidine solution. Sixty third human molars had their oclusal thirds removed to expose flat dentin and were divided into three groups, according to erosive protocol: Control (C) with no surface treatment, erosive challenge with Regular Coke (CC), erosive challenge with Light Coke (CL). The erosive challenge was performed by cycles of 5-min immersions, 3x/day during 5 days. After that, half of the teeth were treated with 2% chlorhexidine solution (1,5ul) and the remaining with deionized water (1,5ul) before adhesion procedure with Adper Single Bond 2® and FiltekTMZ350®. Specimens were stored at 37oC in deionized water for 24 hours. After this period, all specimens were sectioned into sticks (&#x2248;0.81 mm2 to 1mm2). A third of the specimens were tested immediately (I-24 h), for microtensile test. The remaining sticks aged in artificial saliva for 6 months (6m) and 1 year (1y) before testing. The failure mode was analyzed and classified as adhesive, mixed and cohesive in dentin or resin. Bond strength data was analyzed by three-way ANOVA and Tukey tests (p<0.05). Simultaneously, one slice (mesial-distal) of each specimen was analyzed by confocal microscopy for analysis of the interface resin/dentin and tag formation over the aging time. Means and standard-deviation (MPa) of each group (I, 6m and 1y) were: C (38.57±15.36, 26.67±19.37, 12.21±11.24), C-Chx 2% (41.93±9.97, 31.2±17.02, 11.86±10.4), CC (21.80±7.09, 8.33±10.71, 4.70±9.04), CC-Chx 2% (19.85±7.87, 24.32±11.7, 6.19±12.37) CL (22.70±9.63, 10.25±15.6, 4.93±5.54) and CL-Chx 2% (22.40±7.34, 20.94±14.68, 16.05±13.91). Adhesive and/or mixed failures were frequently observed in all specimens. Bond strength of eroded dentin specimens was lower than of the normal dentin specimens, for all testing times. Both normal and eroded dentin showed decrease on µTBS values with time. Although the specimens treated with 2% chlorhexidine solution maintained the bond strength values for 6 months, they reduced significantly, after 1 year. after this period the bond strength values went down. According to confocal microscopy images, no difference in the overall quality of hybrid layer and tags formation among groups was observed. The use of 2% chlorhexidine solution could be an alternative to maintain the stability of bonding interface. More stable bonding strength to eroded dentin with Coca-Light over time, compared to dentin eroded by Regular Cola suggests the implication of their properties on bonding.
36

Avaliação da interface de adesão à dentina humana de um sistema restaurador adesivo à base de silorano, em cavidades de Classe I, analisados por teste de microtração e microscopia óptica / Evaluation of the interface of a silorane based restorative system to dentin of Class I cavities by microtensile bond strength test and optical microscopy

Espinoza, Carlos Andrés Villavicencio 24 May 2013 (has links)
Este estudo teve como objetivo a análise da interface de adesão à dentina humana, de um sistema restaurador adesivo à base de silorano. Foram confeccionadas cavidades com 4mm X 3mm X 5mm em 40 molares humanos extraídos divididos em 4 grupos aleatoriamente: Grupos SB e SB-6m: sistema adesivo (Adper&#x2122; Single Bond) + resina composta (Filtek Z250); Grupos P90 e P90-6m: sistema adesivo (P90 System Adhesive) + resina composta (Filtek P90&#x2122;). Em todos os grupos, as restaurações foram inseridas em 4 incrementos oblíquos. Após a restauração, os dentes foram seccionados em fatias de 0,8mm de espessura em uma máquina de cortes com um disco de diamante. Uma fatia de cada dente foi separada aleatoriamente para análise em microscópio óptico para verificação de fendas na interface adesiva. As demais fatias foram seccionadas em palitos (0,8mm X 0,8mm) para os testes de microtração em uma máquina de ensaios universal EMIC. Os e dos grupos SB e P90 permaneceram em água deionizada em estufa a 370C por 24 horas e os grupos SB-6m e P90-6m permaneceram em água deionizada em estufa a 370C por um período de 6 meses. Os resultados de resistência de união foram submetidos à análise de variância a 2 critérios ANOVA e a presença de fendas internas foi analisada pelo testeChi-quadrado. Houve diferença estatisticamente significante na resistência de união entre os materiais (p>0,05) e tempo de armazenagem. Quanto à presença de fendas internas, foi evidenciada sua presença em todos os grupos, sem diferença etatisticamente significante entre eles (p>0,05). Conclui-se que não houve diferença entre os sistemas restauradores á base de Bis-GMA e de silorano os 2 períodos avaliados (24h e 6 meses). / This study aimed to analyse the adhesive interface to human dentin of a silorane based adhesive system. Cavities were fabricated with 4.0 mm X 3mm X 5mm in 40 extracted human molars randomly divided into 4 groups: Groups SB and SB-6m: adhesive system (Adper&#x2122; Single Bond) + composite (Filtek Z250); Groups P90 and P90- 6m: adhesive system (P90 System Adhesive) + composite (Filtek&#x2122; P90). In all groups, the restorations were inserted in 4 oblique increments. After 24 hours, teeth were sectioned buccolingually into 0.8mm slices with diamond saw. One slice of each tooth was randomly separated for microscope analysis. The other slices were sectioned into 0.8mm X0.8mm sticks for microtensile tests in a universal testing machine EMIC. Sticks of groups SB and P90 remained in deionized water at 370C C for 24 hours and sticks of groups SB-6m and P90-6m remained in deionized water at 370C for a period of six months. After storage period . The results of bond strength were analysed by Two-way ANOVA and the presence of internal gaps was analyzed by chi-square test. There was no significant difference in bond strength between materials (p> 0.05) and storage time. Regarding the presence of internal rifts, their presence was evident in all groups, with no statistically significant difference between them (p> .05).
37

"Estudo comparativo da resistência de união e da interface entre sistemas adesivos e a dentina de molares decíduos humanos" / A comparative study of bond strength and interfacial morphology between adhesives systems and primary human molars dentin.

Ruschel, Henrique Castilhos 02 February 2006 (has links)
O objetivo deste estudo foi avaliar a resistência de união à dentina de primeiros e segundos molares decíduos de sistemas adesivos baseados no condicionamento ácido total e autocondicionantes e analisar a interface de união adesiva sob microscopia eletrônica de varredura. Amostras de dentina de 35 a 65% de distância pulpar (dentina intermediária) foram obtidas do terço médio das faces vestibular e lingual/palatina de 108 molares decíduos, mediante corte com disco diamantado de dupla-face, sob refrigeração. Posteriormente, as superfícies dentinárias foram polidas com lixas de carboneto de silício de granulação 400 e 600. Cinco sistemas adesivos foram empregados nas amostras dos primeiros e segundos molares (n=15/grupo): Adper Single Bond; Prime & Bond NT; AdheSE; Clearfil SE Bond; Adper Prompt L-Pop. Os corpos de prova foram confeccionados com a resina composta Filtek Z250, com uma área de adesão de 2 mm de diâmetro. Após 24 hs de armazenagem em água destilada a 37ºC, fez-se o ensaio de tração a 0,5 mm/min. Na análise da interface de união adesiva entre sistema adesivo e dentina, 50 amostras foram preparadas com os mesmos materiais descritos acima (n=5/grupo). Não foram observadas diferenças estatisticamente significantes entre primeiros (16,02±5,23 MPa) e segundos (16,03±5,05 MPa) molares (ANOVA:p=0,2721). Os valores médios em MPa obtidos para os sistemas adesivos testados foram de 14,32±3,57 (Adper Single Bond), 15,65±3,70 (Prime & Bond NT), 19,47±7,09 (AdheSE), 17,14±5,35 (Clearfil SE Bond) e 14,22±3,20 (Adper Prompt L-Pop). O sistema adesivo AdheSE apresentou o maior valor e diferença estatisticamente significante com os demais grupos (Tukey=3,47), com exceção do Clearfil SE Bond, com o qual não diferiu estatisticamente. Nas demais comparações não foram encontradas diferenças estatísticas significativas. A análise ao microscópio eletrônico de varredura demonstrou a formação de camada híbrida e “tags" em todos os sistemas adesivos e nos dois tipos dentários / The aim of this study was to evaluate bond strength of self-etching and total-etching adhesive systems to dentin of first and second primary molars and to analyze the adhesive interface under scanning electron microscopy. Dentin samples pulp distant 35% to 65% (intermediate dentin) were obtained from buccal and lingual surfaces at the middle third of the crown of 108 primary molars by sectioning with a diamond-impregnated disc under water cooling. Dentin surfaces were polished with 400 and 600-grit silicon carbide paper under running water. Five adhesive systems were tested on the first and second primary molar surfaces (n=15/group): Adper Single Bond; Prime & Bond NT; AdheSE; Clearfil SE Bond; Adper Prompt L-Pop. Inverted, truncated cones of resin composite (Filtek Z250) were built with a 2.0 mm bonding diameter. After 24-hour storage in distilled water at 37°C, the specimens were submited to the tensile test at a crosshead speed of 0.5 mm/min. To analyze adhesive interface 50 samples were prepared with the same protocol described above (n=5/group). No differences between first (16.02±5.23 MPa) and second (16.03±5.05 MPa) primary molars bond strength values could be observed (ANOVA:P=0.2721). Bond strength mean values registered in MPa obtained were 14.32±3.57 (Adper Single Bond), 15.65±3.70 (Prime & Bond NT), 19.47±7.09 (AdheSE), 17.14 ±5.35 (Clearfil SE Bond) and 14.22±3.20 (Adper Prompt L-Pop). AdheSE adhesive system presented the greatest bond strength values statistically different to the other groups (Tukey=3.47), while no statistically significant difference was observed for Clearfil SE Bond. In the other comparisons no differences were found. Scanning electron microscopy analysis showed the presence of hybrid layer and tags in all adhesive systems on both dentin types
38

Efeito do modo de aplicação no desempenho de adesivos autocondicionantes simplificados à dentina / Effect of application mode on the performance of simplified self-etch adhesives to dentin

Serrano, Alexandra Patricia Mena 23 March 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:10Z (GMT). No. of bitstreams: 1 Alexandra Serrano.pdf: 5795461 bytes, checksum: d55b3e436e3ca0014b131ab661ce7049 (MD5) Previous issue date: 2010-03-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to evaluate the effect of different application modes on the immediate and 6-month resin-dentin bond strength and silver nitrate uptake. Three one-step self-etch adhesive systems (One Coat 7.0 [OC], Coltène Whaledent; Clearfil S3 Bond [CS], Kuraray and FuturaBond NR [FB], Voco) were applied in a flat superficial dentin surface of thirty human molars under slight [S] or vibratory [V] application modes. Composite build-ups (Opallis, FGM) were constructed incrementally. After water storage at 37 °C for 24 h, teeth were sectioned to obtain sticks with cross-sectional area of 0.8 mm2 to be tested in tension (0.5 mm/min) either immediately [IM] or after 6 months [6M] of water storage. Two bonded sticks from each tooth at each storage time were immersed in a 50% (w/v) solution of silver nitrate (24 h), photo-developed (8 h) and analyzed under SEM. The silver nitrate uptake was measured using the ImageTool 3.0 software. The data from each adhesive were analyzed by two-way ANOVA and Tukey’s test (α = 0.05). The adhesives OC and CS showed higher resin-dentin bond strength values and lower silver nitrate deposition in the immediate time and vibratory application groups. For FB, no significant difference was observed between the two modes of application in the respective storage periods. The vibratory application mode can improve the resin-dentin bonds, reduce the silver nitrate uptake and retard the degradation of the resin-dentin bonds of Clearfil S3 Bond and One Coat 7.0 adhesives. / O objetivo deste estudo foi avaliar o efeito da aplicação vibratória de adesivos autocondicionantes simplificados na resistência de união à dentina e nanoinfiltração, tanto no tempo imediato como após 6 meses de armazenamento em água. A superfície oclusal de trinta terceiros molares foi desgastada até obtenção de uma superfície plana de dentina. Três sistemas adesivos autocondicionantes de 1 passo (One Coat 7.0 [OC], Coltène Whaledent; Clearfil S3 Bond [CS], Kuraray e FuturaBond NR [FB], Voco) foram aplicados de forma suave (SU) ou vibratória (VB) (n=5). Após a construção de coroas de resina composta (Opallis, FGM), os espécimes foram armazenados durante 24 h em água destilada a 37 °C. Ao término deste período os espécimes foram cortados longitudinalmente nas direções “x” e “y” para conseguir palitos com seção transversal de 0,8 mm2. Os espécimes foram testados sob tração (0,5 mm/min) no tempo imediato [IM] ou após 6 meses de armazenamento em água [6M]. Dois espécimes de cada dente nos respectivos períodos de armazenamento foram imersos por 24 h em uma solução 50% por peso, revelados (8 h) e analisados em microscopia eletrônica de varredura. A quantidade de penetração de nitrato de prata na interface adesiva foi medida no software ImageTool 3.0. Os dados de cada adesivo provenientes de cada teste foram submetidos a uma análise de variância de dois fatores (Forma de Aplicação vs. Tempo) e teste de Tukey (α=0,05) para contraste das médias. Maiores valores de resistência de união e menor deposição de nitrato de prata foram observados no tempo imediato e nos grupos de aplicação vibratória para os adesivos OC e CS. FB apresentou baixos valores de resistência de união independente do tipo de aplicação. Pode-se concluir que a aplicação vibratória pode aumentar os valores de resistência de união dos adesivos One Coat 7.0 e Clearfil S3 Bond retardando o processo de degradação destas interfaces.
39

AVALIAÇÃO DO EFEITO DO PROTOCOLO ADESIVO NA RESISTÊNCIA DE UNIÃO DE CIMENTOS RESINOSOS EM COMPÓSITOS CAD/CAM

Hilgemberg, Bruna 22 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-07-24T13:33:46Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Bruna Hilgemberg.pdf: 2456286 bytes, checksum: 1f094c1efd8bce8788da73b56ecf38e8 (MD5) / Made available in DSpace on 2018-07-24T13:33:46Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Bruna Hilgemberg.pdf: 2456286 bytes, checksum: 1f094c1efd8bce8788da73b56ecf38e8 (MD5) Previous issue date: 2018-02-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi avaliar o efeito de diferentes protocolos adesivos na resistência de união de diferentes compósitos CAD/CAM por meio do teste de microcisalhamento (μSBS). Para esse experimento, três tipos de compósitos CAD/CAM foram utilizados: 1) [Lava™ Ultimate CAD/CAM Restorative (3M ESPE) - LU], 2) [Brava block CAD/CAM (FGM)- BR] e 3) [Vita Enamic (Vita Zanhfabrik) - VE]. Quarenta e cinco secções retangulares (10 × 10 × 6 mm) de compósitos CAD/CAM foram utilizados para a avaliação de microcisalhamento, esses blocos foram distribuídos de acordo com as variáveis: Compósitos CAD/CAM (1- LU, 2-BR, 3- VE) vs. sistema de cimentação [1- Prime & Bond Elect (PBE) + Enforce, 2- Scotch Bond Universal (SBU) + Rely X Ultimate, 3- Ambar Universal (AU) + All cem, 4- Silano sem MDP + Enforce, 5- Silano sem MDP + Rely X Ultimate, 6- Silano sem MDP + All Cem, 7- Silano com MDP + Enforce, 8- Silano com MDP + Rely X Ultimate, 9- Silano com MDP + All cem], resultando em 27 grupos experimentais. O sistema adesivo foi aplicado e matrizes de Tygon foram preenchidas com cimento resinoso e fotoativadas. Os espécimes foram armazenados em água (37 °C por 24h) e submetidos ao teste de μSBS, seus resultados foram submetidos ao teste de ANOVA 2-fatores seguido pelo teste de Bonferroni, α = 5%). Quinze secções retangulares adicionais foram avaliados em Microscopia eletrônica de varredura (MEV/EDS) para a análise da morfologia e composição após tratamento de superfície conforme recomendação de cada fabricante. Para os três cimentos utilizados, maiores valores de μSBS foram observados na superfície VE, seguido do LU e do BR respectivamente. A diferença significativa entre os sistemas de cimentação foi observada apenas no compósito VE, que apresentou maiores valores de μSBS, com exceção dos grupos silano com MDP + All Cem, silano sem MDP + Rely X Ultimate e SBU + Rely X Ultimate. Foi encontrado para todos os grupos, pouca ou nenhuma porcentagem de falha coesiva em cimento, maior porcentagem de falha adesiva/mista, com exceção dos grupos VE/AU e VE/silano com MDP/All Cem, VE/silano sem MDP e VE/SBU/Rely X Ultimate e VE/AU e VE/silano com MDP/ Enforce, em que foi encontrado maior porcentagem de falha coesiva em compósitos CAD/CAM. Todos os compósitos apresentaram irregularidades após o tratamento de superfície na análise de MEV, porém maior irregularidade foi observada na superfície do VE, seguido do LU e do BR respectivamente. A análise por EDS, confirmou a composição de cada compósito CAD/CAM e após o tratamento de superfície, houve diminuição da porcentagem de sílica e zircônia apenas para LU. Pode-se concluir que a efetividade do protocolo de cimentação está relacionada ao tipo de compósito CAD/CAM e suas diferentes composições e que independente do protocolo de cimentação, o VE apresentou os melhores valores de resistência ao microcisalhamento em comparação aos outros compósitos CAD/CAM avaliados. / The objective of the present study was to evaluate the effect of different adhesive protocols on the bond strength of different CAD / CAM composites by means of the micro-shear test (μSBS). For this experiment, three types of CAD / CAM composites were used: 1) [Lava ™ Ultimate CAD / CAM Restorative (3M ESPE) - LU], 2) [Brava block CAD / CAM (FGM) Vita Enamic (Vita Zanhfabrik) - VE]. Forty-five rectangular sections (10 × 10 × 6 mm) of CAD / CAM composites were used for the evaluation of micro-shear, these blocks were distributed according to the following variables: CAD / CAM composites (1 LU, 2-BR, 3 - VE) vs. (1) Prime & Bond Elect (PBE) + Enforce, 2- Scotch Bond Universal (SBU) + Rely X Ultimate, 3- Ambar Universal + All Cem, 4- Silane without MDP + Enforce, 5- Silane without MDP + Rely X Ultimate, 6- Silane without MDP + All Cem, 7- Silane with MDP + Enforce, 8- Silane with MDP + Rely X Ultimate, 9- Silane with MDP + All Cem], resulting in 27 experimental groups . The adhesive system was applied and Tygon matrices were filled with resin cement and photoactivated. The specimens were stored in water (37 ° C for 24h) and submitted to the μSBS test, their results were submitted to the 2-factor ANOVA test followed by the Bonferroni test, α = 5%). Fifteen additional rectangular sections were evaluated in Scanning Electron Microscopy (SEM / EDS) for analysis of morphology and composition after surface treatment as recommended by each manufacturer. For the three cements used, higher values of μSBS were observed on the VE surface, followed by LU and BR respectively. The significant difference between the cementation systems was observed only in the composite VE, which presented higher values of μSBS, except for the silane groups with MDP + All Cem, silane without MDP + Rely X Ultimate and SBU + Rely X Ultimate. A higher percentage of adhesive / mixed failure was found for all groups, except for the VE / AU and VE / silane groups with MDP / All Cem, VE / silane without MDP and VE / SBU / Rely X Ultimate and VE / AU and VE / silane with MDP / Enforce, in which a higher percentage of cohesive failure was found in CAD / CAM composites. All the composites presented irregularities after the surface treatment in the SEM analysis, but greater irregularity was observed on the surface of the VE, followed by the LU and the BR respectively. The EDS analysis confirmed the composition of each CAD / CAM composite and after the surface treatment, the percentage of silica and zirconia was reduced only for LU. It can be concluded that the effectiveness of the cementation protocol is related to the type of CAD / CAM composite and its different compositions and that regardless of the cementation protocol, the VE presented the best values of micro-shear strength compared to other CAD / CAM composites evaluated.
40

Dentina afetada por cárie : avaliação e desenvolvimento de adesivo experimental

Schiroky, Priscila Raquel January 2016 (has links)
A Odontologia minimamente invasiva tornou-se possível em decorrência do atual avanço alcançado na Odontologia adesiva, e a remoção seletiva do tecido cariado passou a ser recomendada para dentes com lesões de cárie profunda. Tal preparo cavitário preserva a dentina afetada por cárie (DAC), camada mais interna da dentina cariada que é remineralizável. Entretanto, esse substrato apresenta propriedades mecânicas inferiores e diversos estudos relatam uma resistência de união reduzida. O objetivo do presente estudo foi revisar sistematicamente a literatura quanto a resistência da união dos sistemas adesivos à DAC quando comparada à dentina hígida (DH), assim como a influência das variáveis metodológicas dos estudos in vitro. Além disso, desenvolver e caracterizar uma resina adesiva com a incorporação de um fosfato de cálcio, assim como avaliar o potencial de induzir deposição mineral em dentes com DAC. As buscas foram realizadas nas bases de dados PubMed, Scopus, Web of Science e LILACS. Foram incluídos estudos laboratoriais que investigaram a resistência de união à microtração imediata e longitudinal de sistemas adesivos À DAC natural ou artificial, utilizando DH como controle. Oito artigos preencheram os critérios de inclusão, e uma metaregressão foi realizada para a associação das variáveis independentes do modelo com o desfecho de resistência de união. O modelo final com 5 variáveis explicou 75,6% da variabilidade entre os grupos. Todas as variáveis independentes apresentaram influência significativa no desfecho, e a DAC resultou em menor resistência de união. Sendo assim, uma resina adesiva com a incorporação de α-fosfato tricálcico (αTCP) foi desenvolvida e caracterizada. Para a formulação das resinas adesivas, 66,66% em peso de BisGMA, 33,33% em peso de HEMA e um sistema fotoiniciador foram misturados. O αTCP foi adicionado a 2% em peso, originando a resina adesiva teste. Uma resina sem adição de carga foi utilizada como controle. As resinas adesivas foram caracterizadas quanto à taxa de polimerização e grau de conversão, e degradação em solvente. Sessenta dentes permanentes extraídos com lesões de cárie profunda foram submetidos à remoção seletiva do tecido cariado e restaurados utilizando uma das duas resinas adesivas. As amostras foram avaliadas por meio de ensaios imediatos e longitudinais (no decorrer de 6 meses, armazenadas em SBF) de resistência de união à microtração, avaliação da deposição mineral por espectroscopia Raman e dureza Knoop. A dureza Knoop inicial da resina adesiva teste foi maior quando comparada à controle, e não houve diferença entre os grupos em relação ao percentual de variação da dureza Knoop após a imersão em solvente. O grupo teste apresentou maior taxa de polimerização e não houve diferença entres os grupos para o grau de conversão. Não houve diferença entre os grupos para a resistência de união imediata e longitudinal, e ambos os grupos mantiveram estável a resistência de união após 6 meses. A análise da interface em relação à deposição mineral mostrou que houve aumento do conteúdo mineral para os dois grupos. Em relação à dureza Knoop, houve um aumento nos valores após 3 meses, entretanto não houve diferença entre os grupos dentro das diferentes profundidades para cada tempo. Conclui-se que não houve diferença entre os grupos em relação à deposição mineral. / The minimally invasive dentistry became possible due to the current advancement in adhesive dentistry, and the selective removal of carious tissue has been recommended for teeth with deep carious lesions. Such cavity preparation preserves the caries-affected dentin (CAD), the inner layer of carious dentin that is remineralizable. However, this substrate presents low mechanical properties and many studies reported reduced bond strength. The objective of this study was to systematically review the literature on the microtensile bond strength (μTBS) of adhesive systems to (CAD) when compared to sound dentin (SD), as well as on the influence of methodological variables of in vitro studies. Also, to develop and characterize an adhesive resin with the incorporation of a calcium phosphate, as well as evaluate the potential to induce mineral deposition in teeth presenting CAD. The electronic databases PubMed, Scopus, ISI Web of Science and LILACS were systematically searched. Were included in vitro studies that assessed the immediate and aged microtensile bond strength of adhesive systems to natural or artificially created CAD in comparison to SD. Eight studies met the inclusion criteria and were included in a linear meta-regression of microtensile bond strength. The fully adjusted model with 5 methodological variables explained 75.6% of the variability among groups. All methodological variables were associated with microtensile bond strength, and bond strength to CAD was lower than to SD. Thus, an adhesive resin with the incorporation of α-tricalcium phosphate (αTCP) was developed and characterized. To formulate the experimental adhesive resins, 66.66 wt% BisGMA, 33.33 wt% HEMA and a photo-initiator system were mixed. The αTCP at 2 wt% was added, yielding the test adhesive resin. An adhesive resin without filler was used as control. The adhesive resins were characterized regarding polymerization kinetics and degree of conversion, and softening in ethanol. Sixty extracted human posterior permanent teeth with deep carious lesions were submitted to selective removal of carious tissue and restored using one of the two adhesive resins. Samples were evaluated by immediate and longitudinal (6 months, storage in SBF) following tests: microtensile bond strength, mineral deposition by Raman spectroscopy and Knoop hardness. The test adhesive resin showed higher initial Knoop hardness than the control one, and there was no difference between the groups for the percentage of variation of Knoop hardness after solvent immersion. The test group showed increased polymerization rate, and there was no difference between groups for degree of conversion. There was no difference between the groups for immediate and longitudinal microtensile bond strength, and the microtensile bond strength of both groups remained stable after the 6 months. The interface analysis regarding mineral deposition showed an increasing in mineral content for both groups. For Knoop hardness, there was an increase after 3 months, however the groups where not significantly different considering depth and time. It could be concluded that there was no difference between control and test adhesive resin for mineral deposition.

Page generated in 0.3576 seconds