11 |
Avaliação in vitro do tiossulfato de sódio, em diferentes concentrações e tempos de aplicação, na resistência de união à dentina intracoronária tratada com hipoclorito de sódio / In vitro evaluation of sodium thiosulfate, at different concentrations and times of application, in the bond strength to intracoronary dentin treated with sodium hypochloriteCorrêa, Ana Carolina Pimentel, 1989- 22 August 2018 (has links)
Orientador: Caio Cezar Randi Ferraz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T00:11:16Z (GMT). No. of bitstreams: 1
Correa_AnaCarolinaPimentel_M.pdf: 2431017 bytes, checksum: 0e40b6c1be77015400d7410e76397857 (MD5)
Previous issue date: 2013 / Resumo: A resistência de união de sistemas adesivos à dentina é comprometida quando esta é tratada com hipoclorito de sódio (NaOCl). Soluções antioxidantes têm sido propostas a fim de restabelecer os valores de adesão. Embora vários estudos tenham avaliado a eficiência do ascorbato de sódio, outras substâncias devem ser pesquisadas. O objetivo deste estudo foi avaliar a eficácia do tiossulfato de sódio (Na2S2O3), em diferentes tempos e concentrações, no restabelecimento da resistência de união à dentina tratada com NaOCl. Coroas de dentes bovinos foram cortadas de forma a expor a dentina da câmara pulpar. As superfícies dentinárias foram tratadas como se segue: grupo 1- cloreto de sódio a 0,9% durante 30 min.; grupo 2: NaOCl a 5,25% durante 30 min., EDTA a 17% durante 3 minutos e mais NaOCl a 5,25% durante 1 min.; nos grupos 3, 4, 5, 6, 7 e 8 foi realizado o mesmo protocolo do grupo 2, porém seguido da aplicação de Na2S2O3 a 0,5% por 1 min. (grupo 3), 5 min. (grupo 4) e 10 min. (grupo 5) e de Na2S2O3 a 5% por 1 min. (grupo 6), 5 min. (grupo 7) e 10 min. (grupo 8); grupo 9- imersão em cloreto de sódio a 0,9% por 10 min., após o mesmo tratamento realizado no grupo 2. Depois disso, o sistema adesivo Scotchbond Multipurpose foi aplicado na dentina da câmara pulpar, seguido da resina composta Z250. Após armazenamento em 100% de umidade por 24 horas a 37 ºC, 25 palitos foram obtidos a partir das amostras de cada grupo e submetidos ao ensaio de microtração. Os dados convertidos em MPa foram analisados por ANOVA e teste de Fisher (p <0,05). Os grupos 2 e 9 apresentaram resistência de união significativamente mais baixa do que a do controle (grupo 1). Não houve diferença estatisticamente significativa entre a aplicação da solução de Na2S2O3 a 0,5% ou 5%, durante 5 ou 10 min., para aumentar a resistência de união à dentina comprometida pelo tratamento com NaOCl (p> 0,05). Não houve diferença estatisticamente significativa entre os grupos 1 e 8 (p = 0,944), mas ambos são estatisticamente diferentes dos grupos 2, 3 e 9. Todos os grupos estudados apresentaram dois ou mais padrões de fratura, sendo que o predominante foi o coesivo em camada híbrida. Observou-se que os grupos que apresentaram maior resistência de união (Grupos 1 e 8) foram os que apresentaram o maior percentual de fraturas do tipo coesiva em resina ou dentina. Pode-se concluir que o NaOCl reduziu significativamente a resistência de união à dentina da câmara pulpar. O restabelecimento da resistência de união à dentina comprometida pelo tratamento com NaOCl não dependeu da concentração do Na2S2O3, quando este foi usado por 5 ou 10 min. Depois de aplicar por 1min, o Na2S2O3 a 5% é capaz de restaurar a resistência de união à dentina tratada com NaOCl / Abstract: The bond strength to dentin is compromised when it is treated with sodium hypochlorite. Several antioxidant solutions have been proposed in order to reestablish the adhesion values. Although several studies have evaluated the efficiency of sodium ascorbate, other substances should be assessed. The purpose of this study was to evaluate the antioxidant efficiency of sodium thiosulfate (Na2S2O3), at different times and concentrations, in reestablishing the adhesive bond strength to sodium hypochlorite-treated dentin. Crowns of bovine incisors were cut to expose the pulp chamber. The dentin surfaces were treated as follows: group 1: 0.9% sodium chloride for 30 min; group 2: treated with 5.25% sodium hypochlorite (NaOCl) for 30 min, 17% EDTA for 3 min and additional 5.25% NaOCl for 1 min; groups 3, 4, 5, 6, 7 and 8: followed the same treatment performed in group 2, adding the final applications of 0.5% sodium thiosulfate solution for 1 min (group 3), 5 min (group 4) and 10 min (group 5) or applications of 5% sodium thiosulfate solution for 1 (group 6), 5 (group 7) and 10 min (group 8); group 9: immersion in 0.9% sodium chloride for 10 min after the same treatment performed in group 2. After that, Scotchbond Multipurpose adhesive system was applied to pulp chamber dentin, followed by Filtek Z250 composite. After storage in water for 24h at 37oC, twenty-five rectangular sticks were obtained from the specimens of each group and subjected to the microtensile bond test. The data converted to MPa were analyzed by one-way ANOVA and Fisher's test (p<0.05). The groups 2 and 9 had significantly lower bond strength than the control (group 1). There was no statistically difference between application of 0.5% or 5% sodium thiosulfate solution for 5 or 10 min to increase the compromised bonding to NaOCl-treated dentin (p>0.05). There was no statistically significant difference between groups 1 and 8 (p = 0.944), but both are statistically different from the groups 2, 3 and 9. All groups studied presented two or more failure mode and the fractures predominating are the cohesive in the hybrid layer. It was observed that the groups that showed the highest bond strength (Groups 1 and 8) were the ones with the highest percentage of cohesive resin / dentin fractures type. It was concluded that sodium hypochlorite significantly reduced the bond strength to pulp chamber dentin. The bond strength reestablishment on compromised NaOCl-treated dentin do not depended on the sodium thiosulfate concentration when it is used for 5 and 10 min. After applied for 1min, 5% sodium thiosulfate is able to restore the bond strengths to NaOCl-treated dentin / Mestrado / Endodontia / Mestra em Clínica Odontológica
|
12 |
Influence of Erosive and Abrasive Cycling on Bonding of Diferent Adhesive Systems Enamel: An in situ studyCiccone Giacomini,Marina, Casas-Apayco, Leslie, Moreira Machado,Camila, Carvalho de Almendra Freitas,Maria Cristina, Atta,Maria Teresa, Wang, Linda January 1900 (has links)
This study evaluated the impact of orange juice on the bond strength (BS) of dentin bonding systems (DBSs) to enamel surface after simulation with an in situ/ ex vivo erosive cycling. One hundred and ninety two bovine enamel fragments (4x4x2 mm) were obtained and randomized regarding superficial microhardness and distributed to palatal devices for 8 volunteers, in three phases (one for each DBS), containing 8 blocks, which were, allocated in 4 pairs. Daily, these pairs were subjected extraorally to the following conditions: CONTneither erosive nor abrasive challenge; ERO- erosive challenge only; ABR- abrasive challenge only and ERO + ABR- with erosive and abrasive challenges. Erosive cycles (immersion in orange juice, 3 times/day/5 min/5 days) or/and abrasive challenges (electric toothbrush, 3 times/day/1 min/5 days) were performed. After these cycles, all specimens were restored with the adhesive systems Adper Scotchbond Multi Purpose (MP), Adper Single Bond 2 (SB) or Clearfil SE Bond (SE), and the composite resin Filtek Z250. After 7 days, sticks (area ≅1 mm2) were obtained and subjected to the microtensile bond strength test (μTBS) at 0.5 mm/min. Data was statistically analyzed by ANOVA and Tukey tests (a=0.05). Failure modes were determined using a digital microscope (40×). DBS was the only statistical significant factor. SE was the unique DBS not affected in any challenge, whereas MP and SB performed according to the scenario. The adhesive and mixed failures were predominant in all groups. Overall performance suggested that BS to enamel after erosive /abrasive challenged by orange juice was not affected and it was material-dependent
|
13 |
Estudo in vitro do efeito da clorexidina e do etanol na dentina em diferentes condições do substrato dentinário e tempos de armazenagem : Study in vitro the effect of chlorhexidine and ethanol on dentin in different conditions of the dentin substrate and storage times / Study in vitro the effect of chlorhexidine and ethanol on dentin in different conditions of the dentin substrate and storage timesCosta, Ana Rosa, 1977- 05 October 2018 (has links)
Orientador: Regina Maria Puppin Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-10-05T18:49:21Z (GMT). No. of bitstreams: 1
Correr_AnaRosaCosta_D.pdf: 3218831 bytes, checksum: f30505368b581fed81781723b234fbd9 (MD5)
Previous issue date: 2013 / Resumo: O propósito deste estudo foi avaliar a influencia de diferentes tipos de substrato (Capitulo 1) e tratamento com etanol 100% (Capitulo 2) ou digluconato de clorexidina a 2% (CHX) (Capitulo 3) na resistência e longevidade da união compósito/dentina, apos diferentes períodos de armazenagem. Os dentes humanos hígidos foram divididos em 3 grupos, de acordo com o substrato dentinario: (Sd) dentina hígida, (Ci) dentina infectada (manutenção da carie) e (Ca) dentina afetada (remoção parcial de carie). As superfícies oclusais de terceiros molares hígidos foram removidas com disco diamantado dupla face sob refrigeração, a fim de expor a superfície plana dentinaria hígida, a qual foi submetida ao desenvolvimento da lesão de carie artificial com S. mutans. Brocas esféricas foram usadas para remover parcialmente o tecido cariado pigmentado, ate que permanecesse apenas a dentina levemente corada (Ca). Em seguida, os dentes foram novamente subdivididos, de acordo com o tratamento da superfície: Grupo Controle (Ct) - nenhum tratamento (Capitulo 1); Ct e (Et) - aplicação de etanol 100% (Capitulo 2); e, Ct e (CHX) - aplicação de digluconato de clorexidina a 2% (Capitulo 3). O substrato foi condicionado com acido fosfórico a 35% por 15 s, lavado por 30 s e seco com leve jato de ar. CHX ou Et foram aplicados apos o condicionamento acido. O sistema adesivo Adper Single Bond 2 (3M ESPE) foi aplicado de acordo com as recomendações do fabricante e fotoativado por 20 s com a fonte de aparelho de luz XL 2500. Sobre a superfície de união foram inseridos incrementos de 2 mm do compósito Z350 (3M ESPE), polimerizados usando a fonte de luz XL 2500 por 40 s, ate confeccionar um bloco com 6 mm de altura. As amostras foram armazenadas em água destilada a 37o C por 24 horas. Apos, os dentes foram seccionados perpendicularmente a área de união, de modo a obter palitos com área de secção transversal de 1mm2. Os palitos foram armazenadas em três períodos: 24 horas, 6 meses e 1 ano. Em seguida, as amostras foram submetidas ao ensaio de resistência de união a microtração usando a maquina de ensaio EZ test (EZS, Shimadzu) a velocidade de 0,5 mm/minuto. Os dados foram submetidos a Analise de Variância e ao teste de Tukey HSD (?=0,05). A união em Sd mostrou valores de resistência de união significativamente maior quando comparado a Ca e Ci. As amostras armazenadas nos períodos de 6 meses e 1 ano resultou na diminuição da resistência de união, independente do tipo de substrato e/ou tratamento. O etanol não foi efetivo em melhorar a resistência de união para os três substratos de dentina avaliados. A clorexidina não influenciou na resistência de união nos períodos de armazenagem avaliados, independente dos substratos / Abstract: The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate (CHX) and 100% ethanol wet-bonding (Et) on the degradation of the adhesive system bond strength in sound or artificial caries-affected/infected dentin after different storage times under microtensile test (_TBS). The sound teeth were divided into 3 groups, according to dentin substrates: sound dentin, caries-infected dentin (maintained of caries) and caries-affected dentin (partial removal of caries). Non-carious human third molars had their occlusal enamel removed with a slow speed diamond saw, under copious water-cooling to expose a flat-surfaced sound dentin, which was submitted to the microbiological challenge (S. mutans) for the development of artificial caries. Spherical drill was used to remove soft pigmented carious tissue till hard and slightly pigmented dentin remains (Ca). After, the teeth will be assigned into 3 subgroups according to surface treatment: water wet- bonding (Ct) (Chapter 1); Ct and 100% ethanol application (Et) (Chapter 2); and, Ct and chlorhexidine digluconate 2% application (CHX) (Chapter 3). The substrate will was etched with 35% phosphoric acid gel for 15 s, rinsed for 30 s with tap water and dried with oil/water-free air. The CHX or Et was applied for 60 s, just after etching with 35% phosphoric acid gel. The adhesive system Adper Single Bond 2 (3M ESPE) was applied according to the manufacturer's instruction and polymerized for 10 s by a light-curing unit XL 2500. The bonded surfaces were coupled with a composite resin Filtek Z350 (3M ESPE) applied in 2 mm increments and polymerized using a curing unit XL 2500 (3M ESPE) for 40 s for each increment and to build 6 mm thick block. The restored teeth were stored in distilled water at 37o C for 24 h. After this period, the restored teeth were longitudinally sectioned across the bonded interface to produce a series of 1.0mm2 beams. The specimens were then submitted to three storage periods: 24 hours, 6 months, or 1 year. Afterwards, the storage periods, the specimens were submitted to a microtensile bond strength (_TBS) using EZ test machine (EZS, Shimadzu) at a crosshead speed of 0.5 mm/min until failure. Data were submitted to ANOVA and Tukey's HSD test (?=0.05). The bonding with sound dentin showed _TBS values significant higher when compared to caries-affected and caries-infected dentin. The 6 months and 1 year storage periods resulted in decreased bond strengths for all dentin conditions and/or treatment. The ethanol was not effective to improve the _TBS for the three dentin substrates evaluated. The CHX did not affect the 24- hour, 6 and 12 months _TBS, independent of the tested dentin substrates / Doutorado / Materiais Dentarios / Doutora em Materiais Dentários
|
14 |
Degradação quimica da união de materiais adesivos ao substrato dentinario : analise mecanica e micromorfologica / Chemical degradation of adhesive materials bonded to dentin substrate : mechanical and micromorphologic analysisCorrer, Ana Rosa Costa, 1977- 05 October 2018 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-10-05T18:32:34Z (GMT). No. of bitstreams: 1
Costa_AnaRosa_M.pdf: 3213917 bytes, checksum: 992b632a45094f40763749a7a2048776 (MD5)
Previous issue date: 2009 / Resumo: O propósito neste estudo foi avaliar o efeito da ciclagem dinâmica de pH (solução DES/RE) e o tempo de armazenagem na degradação da união resina/dentina, por meio do ensaio de resistência da união à microtração e quantificar os íons flúor liberados do sistema adesivo. A superfície da face oclusal de terceiros molares humanos extraídos foi desgastada com lixa de carbeto de silício de granulação 600. Em seguida, os dentes foram separados em 2 grupos de acordo com o sistema adesivo utilizado (n=4): Clearfil Protect Bond (PB) (Kuraray) e Clearfil SE Bond (SE) (Kuraray). Um bloco de resina composta TPH (Dentsply) de aproximadamente 6 mm de espessura foi unido ao dente com os sistemas adesivos, preparados de acordo com as recomendações do fabricante e cada camada de 2 mm de espessura foi irradiada por 40 segundos. Após 24 horas em umidade relativa à 37º C, as amostras foram seccionadas perpendicularmente à área de união, para obter palitos com área de secção transversal de 1mm2 e separados em 6 grupos de acordo com o período de armazenagem: G1 - PBI (imediato - controle); G2 - PBC (ciclagem dinâmica de pH); G3 - PBA (armazenagem em água deionizada por 140 dias); G4 - SEI (imediato - controle); G5 - SEC (ciclagem dinâmica de pH); e, G6 - SEA (armazenagem em água deionizada por 140 dias). Em seguida, os palitos foram submetidos ao ensaio de resistência de união à microtração em máquina de ensaio universal (Instron) a velocidade de 0,5 mm/minuto. Para análise da liberação de flúor, os palitos foram armazenados individualmente em 1 mL de solução DES (n=8), RE (n=8) ou água deionizada (n=23) para o sistema adesivo Clearfil Protect Bond com um eletrodo íon específico conectado a um potenciômetro, usando 0,05 mL do sistema tampão concentrado TISAB III adicionado a 0,5 mL da solução da amostra, por 1 a 4 (DES, RE e água deionizada) e 30 dias (água deionizada). Os dados foram submetidos à Análise de Variância, ao teste de Tukey (5%) e ao teste de Friedman's. Os valores de resistência de união à microtração (MPa) foram: 30,4±11,6 (PBI), 29,5±9,1 (PBC), 27,1±11,6 (PBA), 28,9±11,1 (SEI), 27,1±7,6 (SEC) e 21,3±10,9 (SEA). Nenhuma diferença estatística foi observada entre os dois sistemas adesivos em todas as condições de tratamento (p>0,05). O PBI e o SEI apresentaram valores de resistência de união à microtração significativamente maiores em relação ao PBA e ao SEA (p<0,05). A ciclagem dinâmica de pH no PB e SE não mostrou diferença significativa nos valores de resistência de união à microtração, quando comparado com o imediato e a armazenagem em água deionizada por 140 dias (p>0,05). A concentração de flúor presente nas soluções DES/RE foi menor que 0,03125 ppm e nenhuma quantidade esteve presente na água, para o sistema adesivo testado (Clearfil Protect Bond). Conclui-se, portanto, que nenhuma diferença significativa foi observada entre os sistemas adesivos. A
armazenagem em água deionizada por 140 dias diminuiu os valores de resistência da união à microtração, para os dois sistemas adesivos. / Abstract: The purpose of this study was to evaluate the effect of the dynamic chemical
challenge pH (DES/RE solutions) and storage regimen on degradation of resin/dentin-bonding using the microtensile bond strength (µTBS) and quantify fluoride release from the adhesive system. Superficial occlusal dentin of extracted human molars was exposed and wet ground with 600-grit SiC paper. Then, teeth were randomly distributed into 2 groups according to adhesive systems (n=4): Clearfil Protect Bond (PB) (Kuraray) and Clearfil SE Bond (SE) (Kuraray). A block of composite resin TPH (Dentsply) with 6 mm thickness was bonded to the tooth with the adhesive systems according to manufacturer's instructions and each thickness with 2 mm was light cured for 40 seconds. After 24 hours in moist environment at 37oC, the specimens were sectioned perpendicular to the bonding area to obtain 1mm2 sectional area sticks, which were randomly divided into 6 groups according to storage regimen: G1 - PBI (immediate-control); G2 - PBC (pH cycling model); G3 - PBW (140 days water storage); G4 - SEI (immediate - control); G5 - SEC (pH cycling model); and, G6 - SEW (140 days water storage). After that, the sticks were submitted to microtensile bond strength (µTBS) test in a Universal machine (Instron) at a crosshead speed of 0.5mm/min. Fluoride concentration in demineralization (n=8) / remineralization (n=8) solutions and deionized water (n=23) was obtained by collecting 0,5 mL of these solutions and 0,05 mL of TISAB III, from 1 to 4 days ( De, Re and deionized water) and 30 days (deionized water). Fluoride release was detected using a fluoride-specific electrode connected to a microprocessor ion analyzer.The data were submitted to ANOVA and Tukey's tests (p<0.05) and Friedman's tests. Microtensile bond strength- µTBS (MPa) mean values were 30.4±11.6 (PBI), 29.5±9.1 (PBC), 27.1±11.6 (PBW), 28.9±11.1 (SEI), 27.1±7.6 (SEC) and 21.3±10.9 (SEW). There was no significantly statistical difference between PB and SE in all conditions of treatment (p>0.05). The PBI and SEI showed significantly higher µTBS values compared to PBW and SEW (p<0.05). The pH cycling model in the PB and SE didn't show significantly difference on µTBS values when compared immediate and the deionized water storage for 140 days (p>0.05). Fluoride concentrations present in the DES/RE were less than 0.03125 ppm and no in deionized water, regardless of the adhesive system tested. No significantly difference was found between adhesive systems in all conditions. The 140-day water storage decreased the µTBS values from two adhesives systems. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
|
15 |
How 10-MDP functional phosphate monomer and 2% digluconate chlorhexidine solution interact on sound, artificial carious or eroded dentin substrates / Como o monômero funcional fosfatado 10-MDP e a solução de digluconato de clorexidina a 2% interagem em substratos dentinários hígido, cariado e erodido artificialmenteJacomine, Juliana Carvalho 22 March 2019 (has links)
Objective: Carious and eroded dentin represent common modified dental substrates, which mostly require restorative procedures. MDP-based dentin bonding system (DBS) and digluconate chlorhexidine (CHX) are presented as promising agents to minimize intrinsic degradation of the resin-dentin interface by interaction with calcium (Ca). Therefore, the purpose of this study was to explore the possible interaction between MDP in a universal adhesive system with 10-MDP in self-etching mode and CHX on substrates artificially modified by caries and erosion, through microtensile bond strength (TBS). Additional characterization of the adhesive interface was performed by SEM/EDS analyses. Material and methods: Flat dentin surfaces were obtained from 120 specimens (n=20/group) prepared from extracted sound human third molars and randomly divided into three groups according to the dentin substrate: sound-control (S), artificial carious (C) and artificial eroded (E). Half of these specimens were pretreated with distilled water (W) and other half with 2% CHX, constituting 6 groups: SW, S-CHX, C-W, C-CHX, E-W, E-CHX. After, all the specimens were restored with a universal adhesive system (Apder Single Bond Universal) using self-etching mode and two increments of composite resin (Filtek Z-350), following manufacturers instructions. Slices (0.8mm) were obtained to SEM analysis and beams (0.64mm²) were obtained and evaluated by EDS analysis and TBS in universal testing machine (500N/ 0.5mm/min) after 24 hours and 6 months. Data was statistically analyzed by two-way ANOVA and Tukey tests (p<0.05). Results: Substrate type was a statistically significant factor (p<0.0001), whereas the pretreatment (p=0.189), time (p=0.337) and the interaction between three factors (p=0.452) were not significant. Conclusion: Carious and eroded dentin substrates negatively interfered on the bond strength of an MDP- based universal adhesive systems, regardless its use with CHX. Likely, the reduction of available calcium from these substrates impaired the effectiveness of this system. / Objetivo: Substratos dentinários cariados e erodidos representam os substratos modificados mais comuns na prática clínica. Sistemas adesivos baseados em MDP e CHX são apresentados como promissores agentes para minimizar a degradação intrínseca da interface resina-dentina devido a suas interações com cálcio. O objetivo deste estudo foi explorar a possível interação entre MDP em um sistema adesivo universal com 10-MDP em modo autocondicionante e CHX em substratos artificialmente modificados por cárie e erosão através da resistência de união (TBS). Caracterizações adicionais das interfaces adesivas foram realizadas por análise em MEV/EDS. Material e métodos: Cento e vinte terceiros molares hígidos foram preparados e randomizados em três grupos de avaliação de acordo com a condição dentinária (n=20/grupo): hígida (controle), cariada e erodida. Metade dos espécimes foram tratados com água (controle) e a outra metade com solução aquosa de CHX a 2%. Todos os espécimes foram restaurados com sistema adesivo Adper Single Bond Universal no modo autocondicionante e resina composta Filtek Z250, seguindo as instruções do fabricante. Fatias (0,8mm) foram obtidas paras as análises em MEV e, na sequência, palitos (0,64mm²) para as avaliações de EDS e TBS em máquina de ensaios universal (500N/0,5mm/min) depois de 24 horas e 6 meses. Os dados foram submetidos à análise estatística (ANOVA e teste Tukey (p<0,05). Resultados: O tipo de substrato foi o único fator estatisticamente significante (p<0,0001), enquanto o pré-tratamento (p=0,189), tempo (p=0,337) e a interação entre os três fatores (p=0,452) não foram significantes. Conclusão: Substratos dentinários cariados e erodidos interferem negativamente na resistência de união de sistemas adesivos universais baseados em MDP, independente do uso de CHX. Provavelmente a redução da disponibilidade de cálcio nesses substratos prejudica a efetividade deste sistema.
|
16 |
Dentin bonding SEM comparison of dentin surface and resin-dentin interface in primary and permanent teeth : a thesis submitted in partial fulfillment ... for the degree of Master of Science (Pediatric Dentistry) ... /by Jacques Eduardo Nör.Nör, Jacques Eduardo. January 1994 (has links)
Thesis (M.S.)--University of Michigan, 1994.
|
17 |
Avaliação morfológica, físico-química e mecânica longitudinal de adesivo dental experimental manipulado com diferentes concentrações de água /Esteves, Stella Renata Machado Silva. January 2018 (has links)
Orientador: Sergio Eduardo de Paiva Gonçalves / Coorientadora: Paulette Spencer / Banca: Flávia Lucisano Botelho do Amaral / Banca: Taciana Marco Ferraz Caneppele / Banca: Alessandra Cassoni Ferreira / Banca: Renata Marques de Melo Marinho / Resumo: O objetivo desse estudo foi avaliar um adesivo experimental com diferentes concentrações de água, bem como sua degradação morfológica, química, física e mecânica. A primeira etapa envolveu a manipulação do adesivo experimental contendo 45/55% de HEMA e BisGMA, 0.5% de canforoquinona, 0.5% EDMAB e 1% de DPIHP. Foram incorporadas diferentes concentrações de água a partir dessa formulação adesiva (0, 10 e 16%). Os modelos adesivos foram fotopolimerizados e as análises iniciais realizadas: Morfológicas (Estereomicroscopio e Micro-xct); Físicas (Rugosidade-Ru, Sorção-Sor, Solubilidade-Sol); Químicas (Grau de conversão-GC, Mapeamento do espécime com 16% de água e os monômeros liberados pela CLAE); Mecânicas (Resistência flexural-RF, Módulo de elasticidade-ME e Resistência a compressão-RC). Em seguida os espécimes foram divididos conforme a solução de envelhecimento (água, etanol e acetona). Foram realizadas novas análises após o envelhecimento por 2 e 84 dias. Os testes estatísticos ANOVA e Tukey (5%) foram realizados. Os resultados iniciais, sem o envelhecimento, mostraram que as diferentes concentrações de água influenciam as propriedades dos adesivos. Na análise morfológica notou-se a presença de bolhas no espécime com 16% de água. Para a Ru e GC os maiores valores foram encontrados para os espécimes com mais água em sua composição e os menores para 0%. Já nas análises mecânicas, para RF e ME os espécimes com 10% de água foram mais resistentes; e em RC os espécimes com 16% foram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was evaluated an experimental adhesive with different water content, as well the degradation morphological, physical, chemical and mechanical. Firstly the dental adhesive was manipulated with 45/55% of HEMA and BisGMA, 0.5% of CQ, 0.5% EDMAB e 1% of DPIHP. Was added different water content (0, 10 and 16%). The adhesive model was cured and the analysis was done: Morphological (Stereomicroscope and Micro-xct); Physical (Surface Roughness), Sorption, Solubility); Chemical (Degree of convertion, Map of the pore on 16% water content sample and the released monomers- HPLC); Mechanicals (Flexural strength, Modulus of elasticity and Compressive strength). After the these analyzes, the samples were divided to each evaluation into 3 groups according to solution for performed ageing (water, ethanol and acetone). Further analyzes were performed after aging for 2 and 84 days. Statistical tests of ANOVA and Tukey (5%) were performed. Initial results, without aging, showed that the different water content influence adhesive properties. In the morphological analysis, bubbles were present on the sample with 16% water. For Ru and DC all specimens differed from each other, with the highest values for the specimens with 16% and the lowest to 0%. In the mechanical analyzes, for RF and ME the specimens with 10% water were more resistant; and in RC the specimens with 16% were less resistant. After aging it is possible notice cracks on the border of specimens 0% and 16% in the ... (Complete abstract click electronic access below) / Doutor
|
18 |
Pentóxido de nióbio como carga para materiais de base polimérica para uso odontológicoLeitune, Vicente Castelo Branco January 2012 (has links)
O objetivo desta tese foi caracterizar o pentóxido de nióbio (Nb2O5), produzir materiais compósitos de matriz polimérica de uso odontológico e avalia-los. As partículas de Nb2O5 foram caracterizadas com difração de raios-X, microscopia eletrônica de varredura, granulometria a laser, método de Brunauer–Emmett–Teller e espectroscopia micro-Raman. Um adesivo experimental foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 5, 10 e 20 %, em peso). Este adesivo foi avaliado quanto à radiopacidade, grau e cinética de conversão, microdureza e a sua interface com a dentina. Um cimento endodôntico experimental de cura dual também foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 80, 100 e 120 %, em peso). Este cimento foi avaliado quanto à radiopacidade, escoamento, espessura de película, microdureza e grau de conversão (imediatamente, 7 dias e 14 dias após a fotoativação). A avaliação do Nb2O5 mostrou que as partículas utilizadas apresentavam estrutura monoclínica, com formato irregular, com tamanho médio de 38,16 μm, área de superfície de 3,86 m2/g e estrutura química compatível com pentóxido de nióbio. A radiopacidade e dureza do adesivo aumentaram com a incorporação do Nb2O5 e ele pode ser detectado no interior da interface dentina/adesivo. No cimento endodôntico a incorporação do Nb2O5 também aumentou a radiopacidade e a dureza e reduziu o escoamento apenas no grupo com 120 %. O grau de conversão aumentou até 14 dias após a fotoativação, com exceção do grupo com 80%. Após a caracterização do Nb2O5 e da produção dos materiais experimentais, foi feito o depósito de pedido de patente de invenção. Conclui-se que o pentóxido de nióbio é uma nova e promissora partícula para uso em Odontologia como agente de carga. / The aim of this thesis was to characterize the niobium pentoxide (Nb2O5), to produce resin-based composite for dental applications and evaluate them. Niobium pentoxide was characterised by X-ray diffraction, surface area, particle size, micro-Raman and scanning electron microscopy. An experimental adhesive resin was formulated with 0, 5, 10 and 20 wt% Nb2O5. The formulated adhesive resins were evaluated based on microhardness, degree of conversion, radiopacity and interface (resin/dentin) characterisation by micro-Raman. An experimental dual-cured root canal sealer was produced with a methacrylate-based comonomer blend. Nb2O5 was added at four different concentrations: 0, 80, 100 and 120wt%. Radio-opacity, flow, film thickness, microhardness and degree of conversion (after 1, 7 and 14 days) were evaluated. The particles used in this study presented a monoclinic crystalline phase with typical chemical groups, mean size of 38.16 μm and 3.86 m2/g of surface area. Microhardness and radiopacity increased with higher amounts of Nb2O5, and the particles were able to penetrate into the hybrid layers. Microhardness and radiopacity increased with higher amounts of Nb2O5 in the adhesive resin, and the particles were able to penetrate into the hybrid layers. For the endodontic cement, the radiopacity and microhardness increased with the Nb2O5 addition. The flow was significantly smaller for the 120% group. All groups except those with 80wt% had higher values for degree of conversion after 14 days than immediately after photocuring. After the Nb2O5 characterization and the production of experimental materials, an application for patent was done. Niobium pentoxide is a new and promising filler for dental materials production.
|
19 |
Avaliação da resistência de união em dentina de um adesivo de frasco único quando utilizado diferentes fontes de ativaçãoKreidler, Martín Antúnez de Mayolo [UNESP] 14 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-12-14Bitstream added on 2014-06-13T20:51:31Z : No. of bitstreams: 1
kreidler_mam_me_arafo.pdf: 1061515 bytes, checksum: 8631de69ed2363b4ba75419b58ee0e3b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste estudo foi avaliar através do teste de microtração e da análise do padrão de fratura, o efeito da luz halógena e LED, na ativação de um adesivo de frasco único. Superfícies dentinárias planas foram criadas em 16 dentes terceiros molares hígidos. Os dentes foram aleatoriamente divididos em 4 grupos: Grupo G1 - Aparelho de luz halógena - KM-200R®; Grupo G2 - Aparelho LED - Ultraled®; Grupo G3 - Aparelho LED - UltraLume®LED5 e Grupo G4 - Aparelho LED - Biolux Single V®. O procedimento restaurador foi realizado utilizando o adesivo Single Bond® e a resina composta InTen-S®. Após as restaurações, os dentes foram armazenados em água destilada e estufa a 37ºC por 24h. A seguir, os mesmos foram cortados, resultando em espécimes com área de aproximadamente 1 mm2, que foram selecionados e submetidos ao teste de microtração para posterior observação do padrão de fratura no microscópio digital. Os resultados, submetidos a análise estatística mostram que o grupo G2 teve média de resistência de união significativamente menor que os demais grupos, que foram semelhantes entre si. Quanto ao tipo de fratura, houve diferença significativa entre os grupos G1 e G2 e entre os grupos G2 e G4. Entre os outros grupos não houve evidência de diferenças significativas. As falhas de união foram predominantemente do tipo adesivas. Conclui-se que os aparelhos LEDs de segunda e terceira geração utilizados nesta pesquisa podem ser utilizados como uma alternativa viável à luz halógena. / The purpose of this study was to evaluate the effect of halogen light and LED on dentin tensile bond strength and fracture mode analysis. Flat dentin surfaces were created on 16 intact human third molars. The teeth were randomly divided in 4 groups: Group G1 - halogen - KM -200R®; Group G2 - LED - Ultraled®; Group G3 - LED - UltraLume LED5® and Group G4 - LED - Biolux Single V®. The restoration procedure used Single Bond® adhesive and InTen-S® composite resin. The teeth were placed in distilled water and stored at 37ºC for 24 hours. Then, they were cut on serial sections to obtain 1 mm2 area. The samples were submitted to micro tensile test and after words, the fractures were analysed with a digital microscope. The statistical analysis showed that all in all groups, except Group G2, which had a significant smaller tensile bond strength ratio. The fracture mode analysis showed that there were significant difference when comparing groups G1 / G2, and G2 / G4. There is no evidence of relevant differences among the other groups. Adhesive fracture was the most common fracture mode. As a conclusion, second and third LED generation used in this research could be use as an alternative to the conventional halogen lamp. Keyword: Dentin-bonding agents; tensile strength.
|
20 |
Efeito de diferentes soluções de clorexidina na produção e estabilidade mecânica da união resina-dentina afetada por cárie /Ricci, Hérica Adad. January 2012 (has links)
Orientador: Josimeri Hebling / Banca: Daniela Prócida Raggio / Banca: Regina Maria Puppin Rontani / Banca: Edson Alves de Campos / Banca: Welingtom Dinelli / Resumo: O objetivo geral deste trabalho, o qual foi dividido em três estudos, foi avaliar o efeito da clorexidina (CLX) em diferentes excipientes, etanol e água, na produção e estabilidade mecânica da união resina-dentina afetada por cárie. Materiais e Métodos. No primeiro estudo foi avaliada a influência da CLX em solução aquosa ou alcoólica na umectabilidade da dentina hígida e afetada por cárie por um sistema adesivo. Foram preparadas superfícies planas de dentina em 100 terceiros molares hígidos, das quais 50 foram submetidas ao processo microbiológico de indução de cárie. Dentro de cada condição de substrato, hígido e afetado por cárie, as superfícies foram divididas em 5 grupos (n=10): com smear layer (SL), sem smear layer impregnada com água, sem smear layer impregnada com CLX em água, sem smear layer impregnada com etanol e sem smear layer impregnada com CLX em etanol. Ângulos de contato entre a superfície de dentina e o sistema adesivo Single Bond 2 foram mensurados por meio de um goniômetro, e os dados submetidos aos testes de ANOVA e Tukey ( =0,05). No segundo estudo foi avaliado o efeito da solução de CLX em diferentes excipientes, etanol ou água, na presença de colágeno exposto na união resina-dentina hígida e dentina afetada por cárie. Foram produzidas superfícies planas de dentina em 24 molares humanos hígidos, sendo metade delas cariadas artificialmente. Os dentes foram divididos em 8 grupos (n=3) segundo o tratamento da dentina após o condicionamento ácido (CLX associada a etanol, CLX associada a água, somente etanol ou somente água) e segundo o tipo de substrato utilizado para a adesão. Espécimes foram produzidos de cada dente e preparados histologicamente para coloração com tricrômico de Goldner. A zona de colágeno exposta (ZC) foi quantificada (μm) em... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose. The overall purpose of this work, divided into three studies, was to evaluate the effect of chlorhexidine (CHX) in different excipients, ethanol and water, on the production and mechanical stability of resin-caries affected dentin bonds. Materials and Methods. In the first study, it was evaluated the influence of aqueous and alcoholic solution of CHX on the wettability of noncarious and caries-affected dentin by an adhesive system. Flat dentin surfaces (n=100) were produced, and 50 were submitted to a biological method of artificial caries induction. Within each type of substrate, noncarious and caries-affected dentin, the surfaces were divided into 5 groups (n=10): with smear layer, smear layer-free impregnated with water, smear layer-free impregnated with CHX in water, smear layer-free impregnated with ethanol and smear layer-free impregnated with CHX in ethanol. Contact angles between the dentin surface and the adhesive system Single Bond Plus were measured by using a goniometer and the data were submitted to ANOVA and Tukey tests ( =0.05). In the second study, it was evaluated the effect of CHX in different excipients, ethanol or water, on the collagen exposure in interfaces produced on noncarious and caries-affected dentin. Flat dentin surfaces were prepared in 24 noncarious human molars, and half of them were artificially decayed. The surfaces were divided into 8 groups (n=3) according to the treatment of the dentin after its conditioning with phosphoric acid (CHX in ethanol, CHX in water, water and ethanol) and to the type of substrate used for the adhesive procedures. Specimens were produced from each tooth and histologically prepared to be stained by Goldner's trichrome. The zone of exposed collagen (CZ) was quantified (μm) under a light microscope and the data submitted to... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.107 seconds