• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 437
  • 135
  • 21
  • 18
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • 6
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 640
  • 365
  • 209
  • 194
  • 184
  • 163
  • 113
  • 104
  • 98
  • 96
  • 87
  • 85
  • 83
  • 77
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Estudo da alteração da dimensão vertical de oclusão (DVO) em dentaduras completas variando-se a fase de inserção da resina acrílica para microondas em mufla e utilizando-se a técnica do propiciador de espaço / Influence of acrylic resin stages and of the space propitiator technique on vertical dimension of occlusion in total dentures

Oshiro, Adriana 21 September 2007 (has links)
As alterações de dimensão vertical de oclusão em dentaduras completas foram avaliadas através da mudança da fase de inserção (arenosa ou pegajosa) da resina acrílica de microondas Onda-Cryl em muflas próprias com a utilização ou não da técnica do propiciador de espaço. Foram confeccionadas dentaduras superiores em cera, corretamente articuladas com uma dentadura inferior previamente montada em articulador semi-ajustável, sendo realizadas as medidas de dimensão verticais iniciais através de um relógio micrométrico. Estas próteses superiores em cera foram divididas em quatro grupos de 10 elementos cada para acrilização: grupo F (inserção da resina acrílica na fase fibrilar em mufla, sem a utilização da técnica do propiciador de espaço), grupo FP (inserção na fase fibrilar, com utilização da técnica do propiciador de espaço), grupo A (fase arenosa, sem a técnica do propiciador de espaço) e grupo AP (fase arenosa, com a técnica do propiciador de espaço). O ciclo de polimerização em todos os grupos foi de 3 minutos a 30% da potência, 4 minutos com 0 (zero) de potência e 3 minutos a 90% da potência, em forno microondas de 800 Watts, conforme as instruções do fabricante. Após a acrilização, as dentaduras superiores, juntamente com seus respectivos modelos, foram remontadas no articulador semi-ajustável (através da técnica do split-cast com imã), onde novas medidas foram tomadas e comparadas com as iniciais. Os resultados foram submetidos à análise estatística e demonstraram que a técnica do propiciador de espaço foi efetiva na diminuição das alterações de dimensão vertical e que a mudança da fase de inserção da resina, embora não estatisticamente significante, também provoca uma redução dessas alterações. / Changes in vertical dimension of occlusion in maxillary complete dentures were evaluated after modifying Onda Cryl acrylic resin insertion stages (sandy or stringy) in specifics flasks or employing or not a space propitiator technique. Forty maxillary wax total dentures were made and randomly assigned in four groups, each one with 10 elements. They were all mounted in a semi-adjustable articulator and the initial vertical dimension measurements were recorded by the means of a gauging device attached to the articulator\'s guideline. The 4 groups were: Group S (Stringy stage, no use of space propitiator technique), Group SP (Stringy stage associated with the space Propitiator technique), Group Sn (Sandy stage, no use of space propitiator technique) and Group SnP (Sandy stage associated with the space Propitiator technique). All specimens were processed in a domestic microwave oven according to Onda cryl manufacturer\'s instructions. After the curing cycle, the flask was removed from the oven, remaining on the bench until its full cooling and the remounted standardized dentures were replaced in the articulator were reevaluated. The vertical dimensional alterations values were submitted to statistical analysis. Space propitiator technique was effective on reducing the vertical dimension alterations and changing the resin stage (sandy instead stringy stage) results in minor alterations on vertical dimension, although not statiscally significant.
312

Análise do comportamento da cor de restaurações cerâmicas sem metal avaliadas por diferentes métodos : estudo clínico prospectivo /

Martini, Ana Paula. January 2015 (has links)
Orientador: Eduardo Passos Rocha / Banca: Renato Herman Sundfeld / Banca: Carlos Marcelo Archangelo / Banca: Manoel Martin Junior / Banca: Paulo Henrique dos Santos / Resumo: Introdução: O processo de interpretação da cor em restaurações cerâmicas delgadas pré e pós-tratamento é um desafio. Os métodos de avaliação dos resultados são diversos e a literatura não é clara em apontar o mais eficaz e eficiente. A questão é ainda mais relevante diante da variação do cimento resinoso utilizado. Proposição: Após variar o tipo de cimento resinoso utilizado, o objetivo deste estudo foi avaliar o comportamento da cor de restaurações cerâmicas em dentes com demanda estética, ao longo de 1 ano após o tratamento, com o auxílio de diferentes métodos de acompanhamento (espectrofotômetro, fotografias, vídeos e avaliação clínica) em um estudo clínico longitudinal e prospectivo. Materiais e Métodos: Foram selecionados 28 pacientes, perfazendo um total de 204 dentes restaurados (89 facetas laminadas, 57 coroas totais ou parciais e 58 lentes de contato). 76 restaurações foram cimentadas com Rely X veneer, 71 com Variolink veneer e 57 com Rely X U200. Foram realizadas mensurações de cor com espectrofotômetro, fotografias digitais e vídeos gravados no decorrer do tratamento e em controles periódicos (inicial, 30 dias, 180 dias e 1 ano após a cimentação). Grupos formados por observadores externos (pacientes, alunos de 1º e último ano de graduação, pós-graduandos e especialistas) avaliaram, aleatoriamente, as imagens obtidas inicialmente e ao final do tratamento, segundo perguntas sobre a satisfação ou não com o resultado estético do caso. Resultados: Os dados obtidos com o espectrofotômetro foram submetidos a testes estatísticos que revelaram diferença significativa apenas entre os tempos avaliados, contudo, para todos os tipos de restauração foi observada estabilidade de cor após, no máximo, 180 dias da cimentação. Não houve diferença estatística entre a satisfação dos diferentes grupos... / Abstract: Introduction: The process of interpretation of color in thin ceramic restorations pre- and post-treatment is challenging. The evaluation methods of the results are diverse and literature is not clear in pointing out the most effective method. The question is even more relevant given the variation of the resin cement used. Purpose: After changing the type of resin cement used, the aim of this study was to evaluate the color behavior of ceramic restorations in teeth with aesthetic demand, over 1 year after treatment, with the help of different monitoring methods (spectrophotometer, photographs, videos and clinical assessment) in a longitudinal and prospective study. Materials and Methods: 28 patients were selected, for a total of 204 restored teeth (89 veneers, 57 crowns and 58 contact lenses). 76 restorations were cemented with Rely X veneer, 71 with Variolink veneer and 57 with Rely X U200. Color measurements were made with a spectrophotometer, digital photos and videos taken during treatment and periodic controls (initial, 30 days, 180 days and 1 year after cementation). Groups formed by outside observers (patients, students of 1st and last year of undergraduate, graduate students, and experts) evaluated, randomly, images obtained initially and after treatment, according to questions on satisfaction or not with the aesthetic outcome of the case. Results: The data obtained with the spectrophotometer were subjected to statistical tests which showed a significant difference only between the time periods; however, for all types of restoration, color stability was observed after a maximum of 180 days after cementation. There was no statistical difference between the satisfaction of different groups of outsiders observers with the aesthetic result of the cases for both the photos and for videos, although they videos have obtained the highest... / Doutor
313

Determinação da tensão de falha de lascamento da porcelana de cobertura em prótese livre de metal utilizando análise de imagem /

Silva, Elielson Nóbrega da. January 2018 (has links)
Orientador: Marcos Yutaka Shiino / Coorientador: Alberto Noriyuki Kojima / Banca: Vinícius Anéas Rodrigues / Banca: Vivian Silveira dos Santos Bardini / Resumo: A introdução da zircônia na Odontologia deu-se pela necessidade de melhores propriedades mecânicas dos materiais cerâmicos, pois com a crescente demanda estética, os cerâmicos tornaram-se materiais de largo uso, devido às suas propriedades estéticas e mecânicas. Em busca dessas propriedades, vários estudos analisaram a taxa de sobrevivência de restaurações zircônia-porcelana, relatando como uma das causas de falha a fratura precoce da porcelana de cobertura e o aumento significativo nos relatos clínicos de lascamento da porcelana de recobrimento aplicada sobre "coping" de zircônia. Diante desse problema, o objetivo deste trabalho foi determinar a tensão de falha no lascamento a partir de casos de clínicos e experimentais pertinentes a esse fenômeno em próteses fixas livres de metal .Foram coletados dados de artigos dos últimos 15 anos, por meio das bases de dados Pubmed e Google Schoolar, sendo selecionados para essa revisão os que obtiveram melhor abordagem do assunto, dando ênfase às possíveis causas de falhas nas restaurações cerâmicas dos casos clínicos e os ensaios realizados, visando um melhor entendimento desse fenômeno, via análise quantitativa e qualitativa, para melhor utilização e aproveitamento desse material na Odontologia. Para determinação da tensão de falha, foi empregada a mecânica da fratura linear elástica e determinado o fator de correção da trinca com base nas dimensões da trinca.Com a presente pesquisa, nota-se que amplitude de tensão influencia no proce... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The introduction of zirconia in dentistry was due to the need for better mechanical properties of ceramic materials, because of an increasing aesthetic demand. Ceramics became widely used materials due to their aesthetic and mechanical properties. Aiming at these properties, several studies have analyzed the survival rate of zirconia-porcelain restorations, reporting as one of the causes of failure. Early porcelain fracture coverage and a significant increase in clinical reports of veneering porcelain applied over "coping "of zirconia. In view of this problem, the objective of this work was to determine the failure causes of chipping from clinical and experimental cases associated to this phenomenon in fixed metal free prostheses. Data from articles of the last 15 years were collected through the Pubmed and Google Schoolar databases. Those who obtained the best approach to the subject were selected for this analysis, emphasizing the possible causes of failures in the ceramic restorations of the clinical cases and the tests performed. Aiming for a better understanding of this phenomenon, via quantitative and qualitative analysis, to better use this material in dentistry. To determine the failure causes, linear elastic fracture mechanics were used and the crack correction factor was determined based on the crack dimensions. With the present research, it is noticed that stress amplitude influences in the fracture process, although it has not pointed exactly the cause of the frac... (Complete abstract click electronic access below) / Mestre
314

EFEITO CLÍNICO DO USO TÓPICO DE UNCARIA TOMENTOSAWILLD D.C.EM PACIENTES COM ESTOMATITE PROTÉTICA

Tay Chu Jon, Lidia Yileng 30 July 2013 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-09-11T12:20:53Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Lidia Yileng.pdf: 2407431 bytes, checksum: 8e4f36ecd67d4196231ab479788b77c2 (MD5) / Made available in DSpace on 2018-09-11T12:20:53Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Lidia Yileng.pdf: 2407431 bytes, checksum: 8e4f36ecd67d4196231ab479788b77c2 (MD5) Previous issue date: 2013-07-30 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / A Estomatite protética (EP) é uma doença inflamatória crônica que afeta usuários de prótese removível, sendo a Candida spp. o principal agente etiológico. Uncaria tomentosa, conhecida como unha de gato, é utilizada usualmente na medicina alternativa para o tratamento de diversas doenças. O propósito deste estudo clínico randomizado duplo cego foi determinar a eficácia de um gel de Uncaria tomentosa Willd D.C. contra a EP. Cinquenta pacientes portadores de EP foram distribuídos aleatoriamente em três grupos para receber tratamento contra a doença: grupo M: gel de miconazol 2% como controle positivo; grupo P: gel de hydroxietilcelulose (natrosol) como placebo; e grupo UT: gel de Uncaria tomentosa 2% como o grupo experimental. Os pacientes receberam uma bisnaga contendo o medicamento de acordo com o grupo e foram instruídos para aplicar o gel na base da prótese três vezes ao dia durante uma semana. Além disso, instruções sobre a higiene bucal e das próteses foram prescritas a todos os pacientes. Os pacientes foram avaliados inicialmente (dia 0), após uma semana de tratamento (dia 7) e uma semana após terminado o tratamento (dia 14). A efetividade do tratamento foi avaliada clinicamente pela utilização dos critérios de Newton para grau de EP. Além disso, exame micológico foi realizado contando as unidades formadoras de colônias por mililitro (UFC/mL) de amostras tomadas da mucosa do palato e da superfície interna da prótese. AsCandida spp.foram identificadas com o HiCrome Candida Agar e submetidas ao teste bioquímico Api 20 C AUX. Não houve diferença significativa entre os três grupos (p>0,05) segundo o teste estatístico Kruskal-Wallis e o teste de comparação múltipla de Dunn. Pôde-se observar clinicamente uma diminuição no grau de EP e na análise microbiológica redução significativa da contagem de UFC/mL, após uma semana de tratamento (p<0,05) a qual permaneceu semelhante após 14 dias (p>0,05) nos três grupos avaliados. Foi possível reconhecer C. albicans, C. tropicalis, C. glabrata e C. krusei encontradas nas amostras dos pacientes com EP. Pode-se concluirque o gel de Uncaria tomentosa teve o mesmo efeito que o agente antifúngico miconazol 2%. / Denture stomatitis is a chronic oral disease that affects denture wearers. It presents as an inflammatory reaction in denture-bearing patients, under maxillary prosthesis. Candida spp. has been reported as the principal etiological agent. Despite the existence of a great number of antifungal agents, treatment failure is observed frequently. Uncaria tomentosaWilld D.C., known as cat’s claw, is habitually used in alternative medicine for the treatment of several diseases. The aim of this clinical study was to determine the efficacy of Uncaria tomentosa gel against denture stomatitis (DS). Fifty patients with DS were randomly assigned into three groups to receive either 2% miconazole gel as a positive control (Group M) or 1.5% hydroxyethylcellulose (natrosol) as a placebo group (Group P) or 2% Uncaria tomentosa gel as the experimental group (Group UT). All patients received their treatment on admission and were told to apply the gel on the base of the denture three times a day for a period of 1 week. In addition, instructions for oral and denture hygiene were prescribed to all patients. DS level was registered initial (day 0), after 1 one week of treatment (day 7) and 7 days after treatment (day 14). The effectiveness of treatment was assessed clinically using Newton’s criteria for severity degree of DS; mycological examination was performed counting colony-forming units per milliliter (CFU/mL) from samples of the palatal mucosa and from the tissue surface or the upper denture. Candida spp. were identified with HiCrome Candida and submitted to the biochemical test API 20 C AUX. Results were statistically evaluated using Kruskal-Wallis test and Dunn’s multiple comparsion test. Clinically it was observed decrease in the severity of DS in all groups (p<0.05). At the mycological examination, significant reduction in number of CFU/ml after one week of treatment (p<0.05) which remained after 14 days (p>0.05) were found in the three groups with no significant difference among the three groups (p < 0.05). It was possible to identifyC. albicans, C. tropicalis, C. glabrata and C. krusei found on the samples of DS patients. Furthermore, it was observed that Uncaria tomentosa gel has the same effect as the antifungal agent.
315

REEMBASADORES RESILIENTES PARA BASE DE PRÓTESE: RUGOSIDADE SUPERFICIAL E ANÁLISE HISTOPATOLÓGICA EM MODELO ANIMAL

Bail, Michele 13 December 2012 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-09-13T18:41:40Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Michele Bail.pdf: 2774179 bytes, checksum: 1f5c1e274fd4373179a7cc4505ff8bd6 (MD5) / Made available in DSpace on 2018-09-13T18:41:40Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Michele Bail.pdf: 2774179 bytes, checksum: 1f5c1e274fd4373179a7cc4505ff8bd6 (MD5) Previous issue date: 2012-12-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi avaliar in vivo o efeito de tratamento térmico pós polimerização em reembasadores resilientes para base de prótese sobre sua biocompatibilidade; além de investigar as alterações em sua rugosidade superficial após 14 dias de utilização em animais. Cinquenta ratos adultos (Wistar, fêmeas), com idade de sessenta dias e massa corporal de 150 g - 250 g foram divididos em cinco grupos de acordo com os materiais testados, dos quais um grupo recebeu placas palatinas confeccionadas em resina acrílica termopolimerizável Lucitone 550 (G2); cinco grupos receberam placas palatinas de Lucitone 550 reembasados com um dos seguintes materiais: Dentusoft (G3), Dentuflex (G4), Trusoft (G5) e Ufigel P (G6); e um grupo foi mantido sem utilização de placas sob as mesmas condições (grupo controle – G1). Para os grupos G2, G3, G4 e G5 foram utilizados 10 animais sendo que metade (n=5) utilizou placas com tratamento térmico pós-polimerização e a outra metade recebeu placas sem tratamento. Após 14 dias os animais foram mortos e os palatos foram fixados em formalina tamponada a 10%. Cortes transversais de 5 μm corados com hematoxilina e eosina (HE) foram analisados com planimetria computadorizada, com o objetivo de mensurar quantitativamente a espessura de queratina (KC), espessura total do epitélio (ET), e comprimentos da interface da camada basal (BL). Mensuração da rugosidade superficial (Ra) das placas foi realizada nos materiais em amostras imediatas ao reembasamento (RaI) e após os 14 dias da utilização (RaF) para os grupos G3, G4, G5 e G6. Os testes Shapiro Wilks e Levene foram aplicados aos dados da planimetria computadorizada a fim de se analisar a normalidade dos resíduos e homogeneidade das variâncias, respectivamente. ANOVA e teste de Tukey foram utilizados para os dados de histomorfometria. O peso dos animais inicial e após 14 dias foram comparados utilizando teste de Wilcoxon. Foi realizado o cálculo do poder da amostra para os dados de rugosidade superficial, os quais foram submetidos ao ANOVA e teste de Tukey. Todas as inferências estatísticas para a análise quantitativa histológica e rugosidade superficial foram realizadas assumindo um nível de significância de 5%. Para NT, os parâmetros histológicos estudados não foram estatisticamente diferentes entre os grupos G2, G3, G4 e G5, nem quando cada um deles foi comparado ao grupo G1 (p ≥ 0,05). Para HT, G4 demonstrou na interface da membrana basal cristas menos alongadas quando comparadas ao G2 (p = 0,037). Quando comparados NT e HT, G2 demonstrou uma diminuição significante de KC (p = 0,037) e de ET (p = 0,003). As médias IRa (2,92 ± 0,87 μm) e FRa (3,35 ± 0,65 μm) foram estatisticamente diferentes (p = 0,016). Ufi Gel P demonstrou uma menor (p = 0,01) media Ra (2,1 ± 0,52 μm) que Dentuflex (3.94 ± 0.81 μm), Trusoft (4,12 ± 0,64 μm) e Dentusoft (3,27 ± 0,64 μm). Trusoft foi mais rugoso que Dentusoft (P > 0,05). O tratamento térmico pós- polimerização foi efetivo em reduzir as alterações histomorfológicas na mucosa palatina de ratos quando o material acrílico para base de próteses Lucitone 550 foi utilizado. Os materiais resilientes testados não causaram alterações significativas na mucosa palatina de ratos Wistar no período testado, segundo a análise histomorfológica quantitativa. Dentuflex, Trusoft e Dentusoft demonstraram maiores alterações na rugosidade superficial após 14 dias quando comparados ao Ufi Gel P. O período de 14 dias in vivo resultou em alterações na rugosidade superficial dos materiais testados. / The aim of this study was to evaluate in vivo the effect of a post-polymerization heat treatment in the biocompatibility of resilient denture base liners, and to investigate the changes on their surface roughness after 14 days of use in animals. Fifty adult rats (Wistar, females), aged sixty days, and body mass of 150g - 200g were divided in five groups according to the materials tested: one group used an acrylic plate made with Lucitone 550 (G2), and five groups tested received one of the following lining materials on the Lucitone 550 plates: Dentusoft (G3), Dentuflex (G4) or Trusoft (G5) and Ufigel P (G6); and one control group (G1) was kept without plates in the same conditions. For the groups G2, G3, G4 and G5 were used 10 rats, when half of the animals from each group (n=5) used plates with no post-polymerization (NT), and the other half received a heat water-bath post-polymerization (HT) before insertion. After 14 days the animals were killed and the palates were fixed in 10% buffered formalin. Sections of 5 μm, stained with hematoxylin and eosin, were analyzed by computerized planimetry to quantitatively assess the keratin layer thickness (KC), the total epithelium thickness (ET) and the basal layer interface lenght (BL). Surface roughness (Ra) of the relined dentures materials tested was recorded immediately after reline (IRa groups) or 14 days after fixing the palatal plates on animals (FRa groups), for the groups G3, G4, G5 and G6. Normality of residuals and homogeneity of the variances were examined by Shapiro-Wilk and Levene’s tests, respectively. ANOVA and Tukey’s test were used to the morpho- histometric data. Animal weight initially and after 14 days were compared using Wilcoxon signed rank sum test. Post hoc power analysis was performed for the Ra data (μm) and analyzed by 2-way ANOVA and Tukey’s test. All the statistical inferences for the histological quantitative analyses and surface roughness were performed assuming a 5% significance level. For NT, there were no statistical differences for the tissue parameters among the groups G2, G3, G4 and G5, nor either when comparing each one with G1 (p ≥ 0.05). For HT, G4 showed less elongated ridges at the basal membrane interface (p = 0.037) than G2. When comparing NT and HT, G2 showed a significant decrease in the KC and ET (p < 0.05). IRa means (2.92 ± 0.87 μm) and FRa means (3.35 ± 0.65 μm) were significantly different (P = 0.016). Ufi Gel showed a lower (p = 0.01) Ra mean (2.1 ± 0.52 μm) than Dentuflex (3.94 ± 0.81 μm), Trusoft (4.12 ± 0.64 μm) and Dentusoft (3.27 ± 0.64 μm). Trusoft was rougher than Dentusoft (p > 0.05). The post-polymerization heat treatment for Lucitone 550 was an effective method to reduce the morpho-histometric changes in the rat palatal mucosa. By means of quantitative data, in this study the resilient chairside lining materials tested did not cause significant histopathologic changes in the rat palatal mucosa for the tested period. Dentuflex, Trusoft and Dentusoft showed greater changes in their surface roughness after 14 days when compared to Ufi Gel P. The period of 14 days in vivo resulted in changes in the surface roughness of the materials tested.
316

Avaliação da adaptação marginal de copings cerâmicos obtidos por diferentes métodos de moldagem /

Pinto, Tatiana Saretta Ferreira. January 2018 (has links)
Orientador: Rodrigo Máximo de Araújo / Banca: Vinícius Anéas Rodrigues / Banca : Eduardo Galera da Silva / Resumo: O objetivo desse estudo foi avaliar a adaptação marginal de copings cerâmicos obtidos pelos métodos de moldagem convencional e escaneamento. Os modelos foram separados em 3 grupos para avaliação e todas as coroas foram confeccionadas sobre um modelo mestre previamente fabricado em CoCr. Grupo 1: Com o auxílio de uma moldeira individual cilíndrica de acrílico foram reproduzidas 10 moldagens com silicona de adição (Panasil) no modelo mestre pela técnica de moldagem dupla e replicados dez modelos físicos em gesso pedra Fuji Rock.Sobre esses modelos foi realizado o enceramento dos copings, confecção dos sprues de cera e sobre eles foi realizada a injeção da cerâmica Grupo 2: foram realizadas 10 moldagens diretas com scanner extraoral (Swing Dental Scanner) no modelo mestre. As imagens foram obtidas através do software Exocad e copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Grupo 3: foram realizadas 10 moldagens diretas com scanner intraoral (CEREC Bluecam) no modelo mestre. As imagens foram obtidas através do software Exocad. Copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Os copings de cerâmica não foram cimentados no modelo mestre, apenas posicionados e mantidos com pressão constante de 1,4 a 1,5 kg durante a medição, com a ajuda de um delineador adaptado para esse trabalho, onde oito pontos eletivos foram usados como referência para med... (Resumo completo, clicar acesso eletrônico abaixo) / The objective of the study was to evaluate the marginal adaptation of ceramic crowns obtained by conventional molding and scanning methods. The models were separated into 3 groups for evaluation and all the crowns were made on a master model previously manufactured in CoCr. For group 1: With the aid of a single cylindrical acrylic tray the master model was molded 10 times with Panasil in the master model by the technique of double molding and replicated ten physical models in stone gypsum Fuji Rock. On these models was done the waxing of the copings, making the sprues of wax and on them was carried out the injection of the ceramics In group 2, 10 direct impressions were performed with the Swing Dental Scanner (Korea) extra oral scanner in the master model. The images were obtained through the software Exocad (GmbH) and copings in IPS-Emax CAD were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramics. In group 3, 10 direct impressions were performed with the CEREC Bluecam intraoral scanner (Sirona Dental Systems) in the master model. The images were obtained through the Exocad (GmbH) software. IPS-Emax CAD copings were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramic. Ceramic copings were not cemented in the master model, only positioned and maintained with a constant pressure of 1.4 to 1.5 kg during the measurement, with the aid of an eyeliner adapted for this work, where eight elective points were used as reference to measure the vertical distance between the end line of the master model and the end line of the copings. The margin at each point was measured 3 times with stereo microscope Discovery V20 (ZEISS). The mean was calculated and submitted to the ANOVA variance test "with a significance level of 5% and the following results were obtained: 66.15μm for group 1; 67.48μm for group ...(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
317

Efetividade clínica de sabonetes líquidos desinfetantes no controle do biofilme presente em próteses totais removíveis /

Tasso, Camilla Olga January 2019 (has links)
Orientador: Janaina Habib Jorge / Resumo: As dificuldades de higienização e controle do biofilme das próteses podem resultar em desequilíbrio da microbiota e desencadear a proliferação dos micro-organismos, inclusive patogênicos. A adoção de métodos que inativem os micro-organismos da superfície da prótese é imprescindível para prevenção e tratamento de infecções. O objetivo deste estudo clínico, randomizado do tipo cross-over foi avaliar,a efetividade de sabonetes líquidos desinfetantes na inativação de micro-organismos presentes em próteses totais removíveis. Vinte e oito participantes totalmente desdentados superiores foram selecionados para o estudo de acordo com a sequencia estabelecida para utilização dos métodos de higienização: HS: hipoclorito de sódio 0,5% (grupo controle positivo); SD: sabonete líquido Dettol; SL: sabonete líquido Lifebuoy; PBS: solução de PBS (grupo controle negativo). O tratamento consistiu na imersão das próteses totais superiores dos participantes nas soluções por 8 horas (overnight), durante sete dias. Neste estudo clínico randomizado adotou-se delineamento cruzado (crossover), onde todos os tratamentos (métodos de desinfecção) foram aplicados a todos os participantes, eliminando, assim, a possibilidade de variação entre os indivíduos em resposta a estes tratamentos. Amostras do biofilme das próteses foram obtidas antes (baseline) e após cada tratamento, utilizando-se swab estéril, e o material microbiológico foi diluído e plaqueado em meios seletivos para Candida spp. O sabonete líqui... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The difficulties related to hygiene and biofilm control on buccal prosthesis may unbalance the microbiota and trigger the proliferation of microorganisms, including pathogens. Adopting methods that inactivate microorganisms at the surface of the prosthesis is essential for preventing and treating infections. The difficulties of sanitizing and controlling the biofilm of the prostheses can result in imbalance of the microbiota and trigger the proliferation of microorganisms, including pathogens. The adoption of methods that inactivate microorganisms on the surface of the prosthesis is essential for the prevention and treatment of infections. The objective of this cross-over randomized clinical trial was to evaluate the effectiveness of liquid disinfectant soaps in the inactivation of microorganisms present in total removable dentures. Twenty-eight upper fully edentulous participants were selected for the study according to the established sequence for use of the hygiene methods: HS: sodium hypochlorite 0.5% (positive control group); SD: Dettol liquid soap; SL: Lifebuoy liquid soap; PBS: PBS solution (negative control group). The treatment consisted in immersing the upper limbs of the participants in the solutions for 8 hours (overnight) for seven days. In this randomized crossover study, all treatments (disinfection methods) were applied to all participants, thus eliminating the possibility of variation among individuals in response to these treatments. Biofilm samples of the p... (Complete abstract click electronic access below) / Mestre
318

Avaliação clínica e laboratorial do efeito de soluções de Hipoclorito de sódio, Cloramina T e Ricinus communis sobre espécies de Candida identificadas no biofilme de próteses totais e palato de indivíduos desdentados totais / Clinical and laboratorial evaluation of the effect of Sodium hypochlorite solutions, Cloramina T e Ricinius communis in Candida species identified in the biofilm of total prostheses and palate of total edentuluos individuals

Badaró, Mauricio Malheiros 30 January 2017 (has links)
Este estudo clínico-laboratorial identificou as espécies de Candida do palato e prótese de indivíduos desdentados totais com estomatite relacionada à prótese (ERP) e avaliou o efeito de soluções desinfetantes para higiene de próteses totais sobre Candida spp.. Sessenta participantes foram distribuídos aleatoriamente em 04 grupos paralelos (n=15); orientados a escovar as próteses e o palato 3 vezes ao dia e imergi-las nas soluções salina (C controle), Hipoclorito de sódio a 0,25% (HS0,25%), Ricinus communis a 10% (RC10%) ou Cloramina T a 0,5% (CT0,5%) por 20 minutos. Amostras de biofilme foram coletadas da prótese e palato no Baseline, após 7 e 37 dias do uso das soluções e semeadas em meio CHROMagar Candida. Após período de incubação foi realizada a identificação presuntiva, verificação da incidência e quantificação de crescimento das espécies de Candida (contagem de UFC). Cepas ATCC das espécies mais incidentes clinicamente foram avaliadas no estudo laboratorial. Biofilmes de C. albicans, C. tropicalis e C. glabrata foram formados sobre espécimes em resina acrílica termopolimerizável e imersos nas soluções por 20 minutos. Água destilada foi utilizada como controle. As variáveis de resposta foram crescimento de colônias (contagem de UFC), metabolismo celular (método de XTT), produção de enzimas hidrolíticas (kits específicos), formação de hifas (contagem de células em câmara de Newbauer) e quantificação de células vivas (microscopia de epifluorescência). A capacidade de remoção de biofilme pelas soluções também foi avaliada por meio de microscopia de epifluorescência. Para o estudo clínico, análises descritivas foram utilizadas para interpretação dos dados quanto às características sociodemográficas da amostra, identificação e incidência das Candida spp. Os resultados de crescimento celular (UFC) foram analisados pelos Testes Kruskal-Wallis e Friedman. Para o estudo laboratorial, os resultados foram analisados por teste Anova (One-way) e Tukey (capacidade de crescimento e metabolismo celular de C. albicans e C. tropicalis), teste de Kruskal-Wallis (metabolismo celular de C. glabrata; produção de enzimas hidrolíticas; formação de hifas; capacidade de remoção de biofilme) e teste de Wilcoxon (comparação entre quantidade de biofilme vivo e biofilme total). Empregou-se um nível de confiança de 95% (&alpha;= 0,05). As espécies mais incidentes foram C. albicans, seguida de C. tropicalis, C. glabrata e C. krusei. O HS 0,25% reduziu a incidência das três espécies na prótese e palato nos períodos de 7 e 37 dias; o CT 0,5% promoveu redução de Candida spp. somente nas próteses totais. O R. communis diminuiu a incidência de C. tropicalis em ambos os sítios de coleta. Para contagem de UFC, o HS 0,25% e CT 0,5% causaram redução significativa para cepas clínicas e ATCC. O R. communis, in vitro, reduziu a quantidade de UFC de C. glabrata. O HS 0,25% obteve os melhores valores contra atividade metabólica, formação de hifas, manutenção de células vivas e remoção do biofilme das espécies de Candida. As soluções de RC 10% e CT 0,5% causaram diminuição da atividade metabólica. Não houve diferença significante na produção de proteinase por C. albicans e C. tropicalis após exposição às diferentes soluções desinfetantes, com exceção da C. glabrata, em que todas as soluções causaram aumento significativo da produção desta enzima. As soluções não influenciaram a produção de fosfolipase. A CT 0,5% e RC 10% apresentaram resultados intermediários para manutenção de células vivas. A Cloramina T foi mais eficiente que o R. communis para remoção do biofilme de C. albicans e C. tropicalis e menos eficiente para remoção de biofilme de C. glabrata. As soluções de Hipoclorito de sódio a 0,25% e Cloramina T a 0,5% apresentaram os melhores resultados como solução de imersão frente às variáveis estudadas, podendo ser indicadas para uso clínico como desinfetantes para próteses totais. / This clinical-laboratory study identified the Candida species from the palate and complete dentures of edentulous individuals with prosthesis-related stomatitis (PRS) and evaluated the effect of disinfectant solutions for denture hygiene on Candida spp. Sixty participants were randomly assigned in 04 parallel groups (n = 15); They were oriented to brush their prostheses and the palate 3 times a day and immerse them in saline solution (C-control), 0.25% Sodium hypochlorite (HS0.25%), 10% Ricinus communis (RC10%) or 0.5% Chloramine T (CT 0.5%) for 20 minutes. Biofilm samples were collected from the prosthesis and palate in the baseline, after 7 and 37 days of use of the solutions and seeded in CHROMagar Candida medium. After incubation period, the presumptive identification, incidence verification and quantification of Candida species growth (CFU count) were performed. ATCC strains of the most clinically incident species were evaluated in the laboratory study. C. albicans, C. tropicalis and C. glabrata biofilms were formed on heatpolymerised acrylic resin specimens and immersed in the solutions for 20 minutes. Distilled water was used as control. The response variables were colony growth (UFC count), cell metabolism (XTT method), production of hidrolytic enzymes (specific kits), formation of hyphae (counting cells in Newbauer\'s chamber) and quantification of live cells (epifluorescence microscopy). The ability of biofilm removal by the solutions was also evaluated by means of epifluorescence microscopy. For the clinical study, descriptive analyzes were used to interpret the data regarding the sociodemographic characteristics of the sample, identification and incidence of Candida spp. The cell growth results (CFU) were analyzed by the Kruskal-Wallis and Friedman tests. For the laboratorial study, the results were analyzed by the Anova (One-way) and Tukey test (growth capacity and cellular metabolism of C. albicans and C. tropicalis), Kruskal-Wallis test (cellular metabolism of C. glabrata; hidrolytic enzymes production; formation of hyphae; ability to remove biofilm) and Wilcoxon\'s test (comparison of the amount of live biofilm and total biofilm). A confidence level of 95% (&alpha; = 0.05) was used. The most incident species were C. albicans, followed by C. tropicalis, C. glabrata and C. krusei. HS 0.25% reduced the incidence of the three species on the prosthesis and palate in the periods of 7 and 37 days; CT 0.5% promoted reduction of Candida spp. only in dentures. R. communis decreased the incidence of C. tropicalis in both collection sites. For CFU counts, HS 0.25% and CT 0.5% caused significant reduction for clinical strains and ATCC. R. communis, in vitro, reduced the amount of CFU of C. glabrata. The HS 0.25% obtained the best values compared to the metabolic activity, hyphae formation, maintenance of living cells and removal of the biofilm of Candida species. The solutions of RC 10% and CT 0.5% caused the decrease in the metabolic activity. There was no significant difference in proteinase production by C. albicans and C. tropicalis after exposure to different disinfectant solutions, except C. glabrata, in which all solutions caused a significant increase in the production of this enzyme. The solutions did not influence phospholipase production. A CT 0.5% and RC 10% presented intermediate results for the maintenance of living cells. Chloramine T was more efficient than R. communis for biofilm removal from C. albicans and C. tropicalis; and less efficient for biofilm removal from C. glabrata. The solutions of 0.25% Sodium Hypochlorite and 0.5% Chloramine T presented the best results as immersion solution compared to the studied variables and can be prescribed for clinical use as disinfectants for total dentures.
319

Formação de biofilme de Candida albicans na superfície de uma resina acrílica termopolimerizável tratada com polimento líquido / Candida albicans biofilm formation on surface of an denture base resin treated with liquid-polish

Silva, Matheus Jacobina Andrade e 15 June 2012 (has links)
O objetivo deste trabalho foi quantificar a formação de biofilme de Candida albicans e avaliar a integridade da superfície de uma resina acrílica termopolimerizável tratada com os sistemas de polimento líquido Biscover LV (Bisco, Schaumburg, USA) e Surface Coat (Kuraray, Tokyo, Japan), após 30 e 90 ciclos de desinfecção química. Um total de 280 corpos de prova (10 X 10 X 2 mm) foram confeccionados, esterilizados e aleatoriamente divididos em 20 grupos (n=14), de acordo com o tipo de polimento (mecânico de 0,3 ou 3 m, Surface Coat e Biscover LV), número de ciclos testados (0, 30 e 90) e solução utilizada: Nenhuma (controle negativo), Hipoclorito de sódio 1% (experimental) e água destilada (controle positivo). Após exposição às respectivas soluções de acordo com o protocolo adotado, as amostras foram imersas em saliva artificial por 2 h para a formação da película adquirida salivar e então inoculadas com 2 mL de suspensão de C. albicans (1.107 cel/mL) para fase de adesão durante 90 min. Após esta fase, as amostras foram lavadas e imersas em TSB estéril por 24 h para crescimento do biofilme em estufa a 37ºC sob agitação. Para quantificação do biofilme, foi utilizado o método de coloração por Cristal Violeta, em 240 espécimes divididos em 20 grupos de 12 amostras cada. Esta análise foi realizada por espectrofotômetro com comprimento de onda de 595 nm para mensuração do nível de absorbância do sobrenadante obtido após a descoloração do biofilme. Para análise qualitativa da integridade da camada de polimento liquido, 2 amostras de cada grupo (uma contaminada e outra não) tiveram suas superfícies fotografadas em seis campos distintos através do microscópio eletrônico de varredura (MEV). Os resultados foram submetidos o teste paramétrico ANOVA, seguido de teste de Tukey (p<0,05). Comparando os tipos de tratamentos de superfície avaliados dentro do mesmo tempo e soluções testadas não pode-se notar diferença estatisticamente significante entre os grupos de 0,3 m e Biscover LV ou 3 m e Surface Coat quando comparados entre si. Porém quando comparados os grupos de 0,3 m e Biscover LV aos grupos de 3 m e Surface Coat, estes apresentaram diferença estatisticamente significante. A análise em MEV dos corpos de prova colonizados demostrou a presença de C. albicans na superfície do corpo de prova sob a forma de leveduras e hifas em todos os grupos, enquanto que nos não colonizados foi observada uma degradação progressiva em todos os tipos de tratamento de superfície a medida que os números de ciclos e os desafios químicos eram aumentados. Apesar disso, o grupo Biscover LV apresentou uma quantidade de biofilme formada compatível com uma superfície lisa (0,3 m), enquanto que Surface Coat apresentou quantidade de biofilme formada compatível com a superfície rugosa (3,0 m). / The aim of this study was to quantify Candida albicans biofilm formation and evaluate the surface integrity of an denture base resin treated with liquid-polish Biscover LV (Bisco, Schaumburg, USA) and Surface Coat (Kuraray, Tokyo, Japan), after 30 and 90 cycles of chemical disinfection. A total of 280 specimens (10 x 10 x 2 mm) were prepared, sterilized and randomly divided into 20 groups (n = 14), according to the type of polishing (mechanical 0.3 or 3 m, Surface Coat and Biscover LV), number of cycles tested (0, 30, 90) and the solution used: none (negative-control), 1% sodium hypochlorite (experimental) and distilled water (positive-control). After exposure to the respective solutions according to the protocol adopted, the samples were immersed in artificial saliva for 2 h to form the acquired salivary pellicle and then inoculated with 2 mL of C. albicans (1.107 cel / mL) for 90 min to adhesion. After this, samples were washed and immersed in TSB for 24 h to biofilm growth at 37°C. For biofilm quantification, the method of crystal violet staining was used in 240 specimens, divided into 20 groups of 12 samples each. This analysis was performed by a spectrophotometer at a wavelength of 595 nm by measuring the level of supernatants absorbance obtained after the biofilms stain release. For qualitative analysis of the integrity of the liquid-polish layer, two samples from each group (one colonized and one not) had their surfaces photographed in six different fields through the scanning electron microscope (SEM). The results were submitted to ANOVA followed by Tukey\'s test (p<0.05). Comparing the types of surface treatments evaluated, within the same time and tested solutions, can not be noted statistically significant difference between groups of 0.3 m and Biscover LV or 3 m and Surface Coat. But when comparing the groups of 0.3 m and Biscover LV to groups of 3 mm and Surface Coat, there was a statistically significant difference. SEM analysis of the colonized specimens demonstrated the presence of C. albicans in the form of yeast and hyphae in all groups. In not colonized surfaces a progressive degradation was observed that was bigger when the number of cycles and chemical challenges were increased. Nevertheless, the group Biscover LV showed a amount of biofilm similar to a smooth surface (0.3 m), while Surface Coat presented an amount compatible with the roughened surface (3.0 m).
320

Avaliação eletromiográfica e análise da qualidade de vida de edentados totais antes e após o reembasamento das próteses inferiores / Electromyographic evaluation and oral health related quality of life of edentulous before and after mandibular denture relining

Pisani, Marina Xavier 30 May 2012 (has links)
O presente estudo teve como objetivo geral analisar o impacto do reembasamento de próteses totais com reembasadores rígido e macio na atividade eletromiográfica e na qualidade de vida relacionada à saúde oral (OHRQoL) de pacientes edentados totais. Quarenta e quatro usuários de próteses totais superiores e inferiores foram distribuídos em dois grupos. No grupo 1 (n=22), as próteses inferiores foram reembasadas com reembasador macio à base de silicone (Mucopren Soft) e no grupo 2, com reembasador rígido à base de resina acrílica (Kooliner) pela técnica direta. A avaliação eletromiográfica dos músculos masseter e temporal e análise da OHRQoL foram realizadas antes do reembasamento (baseline-T0) e após 90 dias (T90) da intervenção. Para avaliação da OHRQoL, foi aplicado o questionário OHIP-EDENT, composto por quatro domínios, e três possíveis respostas (escores) às questões: nunca (0), às vezes (1) e quase sempre (2). Após normalização do sinal eletromiográfico, os pacientes foram instruídos a realizarem a máxima contração voluntária em MIH (teste estático), e as variáveis consideradas foram: POC (%), tors (%) e total de atividade eletromiográfica ou impacto (&mu;V / &mu; V.s %). Em seguida, mastigaram amendoins, barra de cereal e chocolate (teste dinâmico), com as seguintes variáveis: coordenação neuromuscular (%), frequência (Hz) e impacto (&mu;V / &mu;V.s %). Os resultados foram analisados por meio do modelo linear generalizado (p&le;0,05). A comparação dos escores da OHRQoL indicou diferença significante entre T0 e T90, independente do grupo, representando uma melhoria nas questões relacionadas à mastigação (domínio 1; p=0,007), dor oral e desconforto (domínio 4; p= 0,047) e no OHIP em geral (p=0,025). Não houve diferença entre os grupos para nenhum dos domínios e para o OHIP em geral. Os resultados do POC dos músculos masseter e temporal não indicaram diferença significante entre os tempos (POCmas p=0,147; POCtem p=0,469) e entre os grupos (POCmas p=0,549; POCtem p=0,104). Para o tors, não foi encontrada diferença significante entre os grupos (p=0,971), e, houve redução do tors em T90 (p=0). Não houve diferença significante entre os grupos (p=0,067), para o impacto, que aumentou em T90 (p=0). A coordenação neuromuscular durante a mastigação de chocolate (p=0), barra de cereal (p=0) e amendoim (p=0) aumentou em T90 e não houve diferença significante entre os grupos (chocolate p=0,087; barra p=0,185; amendoim p=0,472). Não foi encontrada diferença significante entre os grupos (p=0,530) e tempos (p=0,685) para a frequência da mastigação de chocolate. Para o amendoim e barra de cereal, a frequência aumentou em T90 (amendoim p=0,03; barra p=0,007) e não houve diferença entre os grupos (amendoim p=0,566; barra p=0,173). O impacto, durante mastigação de chocolate, aumentou em T90 (p=0), onde o grupo rígido apresentou maior valor (p=0,018). Durante a mastigação de amendoim e barra de cereal, o impacto aumentou em T90 (amendoim p=0; barra p=0) e não houve diferença significante entre os grupos (amendoim p=0,428; barra p=0,590). Conclui-se que o reembasamento, promoveu aumento na atividade eletromiográfica dos músculos avaliados, bem como melhorias na função mastigatória e na OHRQoL. Para a maioria das variáveis não houve diferença significante entre os reembasadores macio e rígido. / The present study aimed to analyze the impact of denture relining with hard and soft denture liners in the electromyographic activity and oral health related quality of life (OHRQoL) of edentulous patients. Forty and four complete denture wearers were distributed in two groups. In group 1 (n=22), the mandibular dentures were relined with a soft silicone based liner (Mucopren Soft) and in group 2, with a hard acrylic based denture liner (Kooliner) by chairside procedures. The electromyography of masseter and temporal muscles and the OHRQoL analysis were assessed before relining (baseline-T0) and after 90 days (T90) of the intervention. The questionnaire OHIP-EDENT, that was used to evaluate the OHRQoL, is composed of four domains, and three possible answers (scores) to the questions: never (0), sometimes (1) and almost always (2). After the normalization of the electromyographic signal, patients had been instructed to perform the maximum voluntary contraction in MIH (static test), and the following variables were considered: POC (%), tors (%) and total of electromyographic activity or impact (&mu;V / &mu;V.s %). After that, they performed masticatory movements by chewing peanuts, cereal bar and chocolate (dynamic test), with the following variables: neuromuscular coordination (%), frequency (Hz) and impact (&mu;V / &mu;V.s %). The results were analyzed by means of the generalized linear model (p&le;0,05). The scores comparison of the OHRQoL indicated significant difference among T0 and T90, regardless the group, which represented an improvement in questions related to mastication (domain 1; p=0,007), oral pain and discomfort (domain 4; p= 0,047) and in overall OHIP (p=0,025). There was no significant difference between the groups for none of the domains and for the overall OHIP. Regarding POC of masseter and temporal, no significant differences between times (POCmas p=0,147; POCtem p=0,469) and groups (POCmas p=0,549; POCtem p=0,104) were found. For tors, significant difference between the groups was not found (p=0,971), and, it decreased in T90 (p=0). There was no significant difference between the groups (p=0,067), for the impact, which increased in T90 (p=0). The neuromuscular coordination during chocolate (p=0), cereal bar (p=0) and peanut (p=0) mastication increased in T90 and there was no significant difference between the groups (chocolate p=0,087; cereal p=0,185; peanut p=0,472). Significant difference between the groups (p=0,530) and times (p=0,685) for the frequency during chocolate mastication was not found. For peanut and cereal bar, the frequency increased in T90 (peanut p=0,03; cereal p=0,007) and there was no difference between the groups (peanut p=0,566; cereal p=0,173). The impact, during chocolate mastication, increased in T90 (p=0), and the hard group presented higher values than the soft (p=0,018). For peanut and bar of cereal mastication, the impact increased in T90 (peanut p=0; bar p=0) and there was no significant difference between the groups (peanut p=0,428; bar p=0,590). It can be concluded that the relining increased the electromyographic activity of the evaluated muscles and improved the masticatory function and the OHRQoL. There was no significant differences among the hard and soft denture liners for most of the tested variables.

Page generated in 0.0813 seconds