Avaliação do esmalte dental na remoção de resíduos resinoso fluorescente com diferentes fontes luminosas /

Salomão, Fabio Martins. January 2017 (has links)
Orientador: Renato Herman Sundfeld / Coorientador: Lucas Silveira Machado / Banca: Rodolfo Brunieira Anchieta / Banca: André Pinheiro de Magalhães Bertoz / Banca: Elaine Cristina Guerbach Conti / Banca: Sergio Kiyoshi Ishikiriama / Resumo: Objetivo: Avaliar através de simulação clínica a efetividade da remoção de resíduos fluorescentes do esmalte dental bovino, após remoção de bráquetes ortodônticos, utilizando dispositivos emissores de luz branca e fluorescente. Materiais e Métodos: 180 dentes bovinos anteriores hígidos foram seccionados em discos de esmalte/dentina. A remoção do material resinoso cimentante foi realizada por três operadores. Os dentes foram divididos em quatro grupos de estudo. Os fatores em estudo foram: a fonte de iluminação empregada durante a remoção dos materiais resinosos cimentantes de bráquetes ortodônticos em 4 níveis (n = 45): Convencional (C), LED branco (W), LED fluorescente (F) e fotopolimerizador com filtro fluorescente (FL). Foram consideradas como variáveis de resposta: o tempo para remoção dos resíduos das amostras; a área de remanescente resinoso fluorescente superficial e a mensuração da altura de material adesivo fluorescente remanescente (PICO) e a profundada de esmalte desgastado (VALE). Na comparação entre as técnicas empregou-se o teste Kruskal-Wallis seguido do pós-teste Mann-Whitney U (P≤0,05). Resultados: As Técnicas F e FL apresentaram-se, estatisticamente, semelhantes e as menores medianas de tempo consumido para a remoção do resíduo resinoso. As técnicas C e W apresentaram estatisticamente, a presença de maiores e semelhantes medianas de áreas fluorescentes remanescentes e de PICO (altura do remanescente), com relação as técnicas F e FL; enquanto que as técnicas ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objec&ve: Evaluate, through clinical simulaSon, the effecSveness on the removal of fluorescent resin residues from bovine dental enamel ater brackets debonding using white and fluorescent light emivng devices. Materials and Methods: 180 healthy anterior bovine teeth were secSoned on enamel / denSn disks. The removal of the resinous material was performed by three operators. The teeth were divided into four groups. The factors studied were: the light source used to remove orthodonSc resin residue in 4 levels (n = 45): ConvenSonal (C), white LED (W), fluorescent LED (F) and photocuring unit with Fluorescent filter (FL). Response variables were: the Sme spent to remove the sample residues; The surface area of the fluorescent remaining resin and the depth measurement of the remaining fluorescent adhesive thickness (PEAK) and the enamel thickness removed (VALLEY). In the comparison between the techniques, the Kruskal-Wallis test was used, followed by the Mann-Whitney U post-test (P≤0.05). Results: In terms of Sme, the groups F and FL were similar to each other and staSsScally different for groups C and W. The techniques C and W presented staSsScally, the presence of larger and similar medians of remaining fluorescent areas, in relaSon to the F and FL techniques. The techniques C and W presented, staSsScally, a larger and similar median of peaks than the F and FL techniques. The FL technique staSsScally demonstrated a higher median of valleys than the C technique. The W, F and FL techniques were staSsScally similar to each other, as were C and W techniques. Conclusions: Fluorescent light with a fluorescent resinous material, significantly and effecSvely collaborated in the reducSon of the Sme consumed for evidencing and removal of fluorescent resin residues, allowing an efficient removal ater removal of orthodontic brackets / Doutor
2

Analise in vitro de diferentes metodos da remoção da resina residual no esmalte dentario / Evaluation in vitro different methods of dental enamel residual resin removal

Tavares, Stenyo Wanderley 20 June 2006 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T04:24:28Z (GMT). No. of bitstreams: 1 Tavares_StenyoWanderley_D.pdf: 4135316 bytes, checksum: 2a1db19579aa0bcb7036ac454b9d537d (MD5) Previous issue date: 2006 / Resumo: O objetivo desta pesquisa foi comparar in vitro diferentes métodos de remoção da resina residual do esmalte dentário, após o descolamento de bráquetes. Cinquenta terceiros molares foram separados em 5 grupos (n=10). Foram fixados bráquetes metálicos com o compósito ortodôntico Transbond XT, após condicionamento do esmalte com ácido fosfórico a 37%. Os corpos-de-prova foram armazenados água à temperatura ambiente, por 24 horas. Após a remoção dos bráquetes com pistola removedora (Orthosource), a resina remanescente foi removida por diferentes tipos de tratamento: grupo I ¿ Jato de óxido de alumínio, grupo II ¿ ponta de carboneto de tungstênio (30 lâminas) em alta rotação; grupo III ¿ ponta de óxido de alumínio (Shofu) em alta rotação, grupo IV ¿ sistema Profin, grupo V ¿ alicate removedor de resina. Depois da remoção da resina foi realizado polimento com pasta de pedra pomes e água em todas as amostras. A avaliação foi realizada antes da colagem, depois da remoção e após o polimento, por meio da análise rugosimétrica de superfície e observação em microscopia eletrônica de varredurra. Os valores de rugosidade foram submetidos à análise de variância a ao teste de Tukey (5%). Os resultados demonstraram que em todas as fases, o alicate removedor de resina foi método que mostrou os melhores resultados. Depois da remoção da resina residual, os métodos com broca de carboneto de tungstênio (30 lâminas) e com ponta de óxido de alumínio mostraram os maiores valores de rugosidade com diferença estatística significante em relação aos demais. O polimento foi importante para o restabelecimento da lisura superficial do esmalte, em todos os métodos de remoção da resina residual / Abstract: The purpose of this study was to compare different in vivo methods of dental enamel residual resin removal after brackets debonding. Fifty third molars were separated in 5 groups of 10 teeth. Metal brackets were fixed with Transbond XT orthodontic composite, after enamel conditioning with 37% phosphoric acid. Specimens were stored in water at room temperature for 24 hours. After brackets debonding with a removal plier (Orthosource), residual resin was removed through different treatment methods: Group I- aluminium oxide blaster, group II ¿ high speed tungsten carbide bur (30 laminae), group V ¿ resin removal plier. After resin elimination it was accomplished pumice and water polishing in all specimens. Evaluation was consummated before bonding, after removal, and also after polishing, trrought roughness surface analysis and scanning electron microscopy observation. Roughness values were submitted to variance analysis and Tukey test (5%). Results showed that the removal method which did not present significant statistical difference in roughness surface enamel values in all treatment methods was resin removal plier. Polishing was important for enamel superficial smoothness recovery in all methods for removal residual resin / Doutorado / Ortodontia / Doutor em Radiologia Odontológica
3

Laser de CO2 como auxiliar na remoção de bráquetes estéticos cerâmicos / CO2 laser-assisted debonding for esthetic ceramic brackets

Macri, Rodrigo Teixeira 02 May 2012 (has links)
Este estudo avaliou a eficiência do uso do laser de CO2 com comprimento de onda de 10,6 m como auxiliar na remoção de bráquetes estéticos cerâmicos. Para este estudo foram utilizados 105 pré-molares inferiores humanos recentemente extraídos, que receberam irradiações com laser de CO2 antes da descolagem dos bráquetes. Na primeira fase deste estudo, o objetivo foi mensurar e comparar a temperatura no compósito de colagem do bráquete e na câmara pulpar após aplicação do laser de CO2 , para observar a segurança para o esmalte, bem como se a temperatura era suficiente para fragilizar o compósito, facilitando a remoção do bráquete. Nesta etapa foram utilizados 30 pré-molares inferiores recentemente extraídos, sendo que cada um recebeu 4 irradiações com diferentes protocolos de maneira aleatória. Foram testados 12 diferentes protocolos variando o tempo de irradiação (3 e 5s), a duração do pulso (0,01 e 0,03s) e a potência (5, 8 e 10W). Cada protocolo foi utilizado por 10 vezes (n=10), totalizando 120 irradiações. Em todas as irradiações os corpos-de-prova foram imersos em banho térmico com água a 37º C. Foram encontrados 4 protocolos cuja variação da temperatura na polpa foi menor que 5,5º C, portanto compatível com a saúde da polpa. Na segunda etapa do estudo, o objetivo foi avaliar a resistência ao cisalhamento após a aplicação do laser utilizando os protocolos cuja temperatura na polpa não fosse superior a 5,5º C. Setenta e cinco pré-molares inferiores humanos foram divididos em 5 grupos, dos quais um não foi submetido à irradiação, sendo considerado Controle (C). Nos 4 grupos restantes, irradiações foram realizadas como descrito a seguir: Grupo I (potência 5W; tempo de pulso 0,01s; tempo de aplicação 3s), Grupo II (5W; 0,03s e 3s), Grupo III (8W; 0,01s e 3s) e Grupo IV (10W; 0,01s e 3s). Cada grupo foi formado por 15 corpos-de-prova (n=15). Após a descolagem do bráquete foi avaliado o Índice de Remanescente Adesivo (IRA). Após as mensurações e aplicação da Análise de Variância (ANOVA) e do teste de Tukey foi constatado que o único grupo que apresentou diminuição na força de remoção foi o IV (7,33 MPa) em relação ao grupo C (10,81 MPa) sendo assim considerado seguro e eficaz na diminuição da resistência do compósito. / This study evaluates the efficacy CO2 10,6 m laser-assisted debonding esthetic ceramic brackets. For this purpose it was used 105 recently extracted lower human premolars that were irradiated with CO2 laser before debonding. In the first phase, the objectives were to measure and compare the temperature in composite for bracket bonding and at the pulp chamber after CO2 laser irradiation, to observe the safety for enamel, as well the temperature was enough to softening the composite, making debonding bracket easier. In this part it was used 30 lower premolar recently extracted, and each one received 4 irradiations with different protocols, randomly choose. It was tested 12 different protocols varying time of irradiation (3 and 5s), pulse duration (0,01s e 0,03s) and power (5, 8 and 10W). Each protocol was repeated for 10 times (n=10), resulting 120 irradiations. In every irradiation the teeth tested were immerse in warm water bath at 37o C. It was found 4 protocols with pulp temperature lower than 5,5º C, so this is compatible with pulp health. In the second phase of this study, the objective was to evaluate the shear bond strength after laser irradiation, using the protocols with pulp chamber temperatures lower than 5,5º C. Seventy-five lower human premolars was shared in 5 groups. One group did not receive laser irradiation and considered Control (C) and the other groups the irradiation was made as it follows: Group I (power density 5W; pulse duration 0,01s; irradiation time 3s), Group II (5W; 0,03s, 3s), Group III (8W; 0,01s; 3s) and Group IV (10W; 0,01s; 3s). After results ANOVA and Tukey tests were made. Group IV presented lowering in SBS force (7,33 MPa) when compared with C (10,81MPa). This protocol was founded as a safe and efficient in softening composite layer.
4

Caracterização do esmalte dentário e remanescentes adesivos após a remoção de brackets por meio de tomografia por coerência óptica / Jorge César Borges Leão Filho ; orientador, Orlando Tanaka ; co-orientador, Ana Carla Souza Braz

Leão Filho, Jorge César Borges January 2012 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Inclui bibliografias / Introdução: Os objetivos deste estudo foram (1) avaliar quantitativamente a presença de remanescentes adesivos e fragmentos de brackets sobre o esmalte, além de fraturas deste tecido após a descolagem de brackets metálicos e cerâmicos; (2) quantificar em / Introduction: The aims of this study were (1) to quantitatively evaluate the presence of adhesive remnants and fragments of brackets on enamel and of enamel fractures after the debonding of metal and ceramic brackets; and (2) to quantify the layer of adhe
5

Avaliação do esmalte dental na remoção de resíduos resinoso fluorescente com diferentes fontes luminosas / Evaluation of dental enamel in the removal of fluorescent resin residues with different light sources

Salomão, Fabio Martins [UNESP] 28 August 2017 (has links)
Submitted by Fabio Salomão (salomaofm@me.com) on 2017-10-25T13:11:58Z No. of bitstreams: 1 TESE FINAL - POS DEFESA OK.pdf: 22130957 bytes, checksum: 001852660d064b7d48732b95f0767def (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-10-31T16:03:04Z (GMT) No. of bitstreams: 1 salomao_fm_dr_araca.pdf: 22130957 bytes, checksum: 001852660d064b7d48732b95f0767def (MD5) / Made available in DSpace on 2017-10-31T16:03:04Z (GMT). No. of bitstreams: 1 salomao_fm_dr_araca.pdf: 22130957 bytes, checksum: 001852660d064b7d48732b95f0767def (MD5) Previous issue date: 2017-08-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: Avaliar através de simulação clínica a efetividade da remoção de resíduos fluorescentes do esmalte dental bovino, após remoção de bráquetes ortodônticos, utilizando dispositivos emissores de luz branca e fluorescente. Materiais e Métodos: 180 dentes bovinos anteriores hígidos foram seccionados em discos de esmalte/dentina. A remoção do material resinoso cimentante foi realizada por três operadores. Os dentes foram divididos em quatro grupos de estudo. Os fatores em estudo foram: a fonte de iluminação empregada durante a remoção dos materiais resinosos cimentantes de bráquetes ortodônticos em 4 níveis (n = 45): Convencional (C), LED branco (W), LED fluorescente (F) e fotopolimerizador com filtro fluorescente (FL). Foram consideradas como variáveis de resposta: o tempo para remoção dos resíduos das amostras; a área de remanescente resinoso fluorescente superficial e a mensuração da altura de material adesivo fluorescente remanescente (PICO) e a profundada de esmalte desgastado (VALE). Na comparação entre as técnicas empregou-se o teste Kruskal-Wallis seguido do pós-teste Mann-Whitney U (P≤0,05). Resultados: As Técnicas F e FL apresentaram-se, estatisticamente, semelhantes e as menores medianas de tempo consumido para a remoção do resíduo resinoso. As técnicas C e W apresentaram estatisticamente, a presença de maiores e semelhantes medianas de áreas fluorescentes remanescentes e de PICO (altura do remanescente), com relação as técnicas F e FL; enquanto que as técnicas FL e F postaram, estatisticamente, uma maior mediana de VALE que a técnica C. Conclusões: A associação de emissor de luz fluorescente com um material resinoso fluorescente, colaborou significativamente e de forma eficaz, na redução do tempo consumido para remoção e evidenciação dos resíduos resinosos cimentantes fluorescentes, possibilitando uma remoção efetiva, após a remoção dos bráquetes ortodônticos. / Objective: Evaluate, through clinical simulation, the effectiveness on the removal of fluorescent resin residues from bovine dental enamel after brackets debonding using white and fluorescent light emitting devices. Materials and Methods: 180 healthy anterior bovine teeth were sectioned on enamel / dentin disks. The removal of the resinous material was performed by three operators. The teeth were divided into four groups. The factors studied were: the light source used to remove orthodontic resin residue in 4 levels (n = 45): Conventional (C), white LED (W), fluorescent LED (F) and photocuring unit with Fluorescent filter (FL). Response variables were: the time spent to remove the sample residues; The surface area of the fluorescent remaining resin and the depth measurement of the remaining fluorescent adhesive thickness (PEAK) and the enamel thickness removed (VALLEY). In the comparison between the techniques, the Kruskal-Wallis test was used, followed by the Mann-Whitney U post-test (P≤0.05). Results: In terms of time, the groups F and FL were similar to each other and statistically different for groups C and W. The techniques C and W presented statistically, the presence of larger and similar medians of remaining fluorescent areas, in relation to te F and FL techniques. The techniques C and W presented, statistically, a larger and similar median of peaks than the F and FL techniques. The FL technique statistically demonstrated a higher median of valleys than the C technique. The W, F and FL techniques were statistically similar to each other, as were C and W techniques. Conclusions: Fluorescent light with a fluorescent resinous material, signicantly and removal of fluorescent resin residues, allowing an efficient removal after removal of orthodontic brackets. / CAPES: 1294804
6

Laser de CO2 como auxiliar na remoção de bráquetes estéticos cerâmicos / CO2 laser-assisted debonding for esthetic ceramic brackets

Rodrigo Teixeira Macri 02 May 2012 (has links)
Este estudo avaliou a eficiência do uso do laser de CO2 com comprimento de onda de 10,6 m como auxiliar na remoção de bráquetes estéticos cerâmicos. Para este estudo foram utilizados 105 pré-molares inferiores humanos recentemente extraídos, que receberam irradiações com laser de CO2 antes da descolagem dos bráquetes. Na primeira fase deste estudo, o objetivo foi mensurar e comparar a temperatura no compósito de colagem do bráquete e na câmara pulpar após aplicação do laser de CO2 , para observar a segurança para o esmalte, bem como se a temperatura era suficiente para fragilizar o compósito, facilitando a remoção do bráquete. Nesta etapa foram utilizados 30 pré-molares inferiores recentemente extraídos, sendo que cada um recebeu 4 irradiações com diferentes protocolos de maneira aleatória. Foram testados 12 diferentes protocolos variando o tempo de irradiação (3 e 5s), a duração do pulso (0,01 e 0,03s) e a potência (5, 8 e 10W). Cada protocolo foi utilizado por 10 vezes (n=10), totalizando 120 irradiações. Em todas as irradiações os corpos-de-prova foram imersos em banho térmico com água a 37º C. Foram encontrados 4 protocolos cuja variação da temperatura na polpa foi menor que 5,5º C, portanto compatível com a saúde da polpa. Na segunda etapa do estudo, o objetivo foi avaliar a resistência ao cisalhamento após a aplicação do laser utilizando os protocolos cuja temperatura na polpa não fosse superior a 5,5º C. Setenta e cinco pré-molares inferiores humanos foram divididos em 5 grupos, dos quais um não foi submetido à irradiação, sendo considerado Controle (C). Nos 4 grupos restantes, irradiações foram realizadas como descrito a seguir: Grupo I (potência 5W; tempo de pulso 0,01s; tempo de aplicação 3s), Grupo II (5W; 0,03s e 3s), Grupo III (8W; 0,01s e 3s) e Grupo IV (10W; 0,01s e 3s). Cada grupo foi formado por 15 corpos-de-prova (n=15). Após a descolagem do bráquete foi avaliado o Índice de Remanescente Adesivo (IRA). Após as mensurações e aplicação da Análise de Variância (ANOVA) e do teste de Tukey foi constatado que o único grupo que apresentou diminuição na força de remoção foi o IV (7,33 MPa) em relação ao grupo C (10,81 MPa) sendo assim considerado seguro e eficaz na diminuição da resistência do compósito. / This study evaluates the efficacy CO2 10,6 m laser-assisted debonding esthetic ceramic brackets. For this purpose it was used 105 recently extracted lower human premolars that were irradiated with CO2 laser before debonding. In the first phase, the objectives were to measure and compare the temperature in composite for bracket bonding and at the pulp chamber after CO2 laser irradiation, to observe the safety for enamel, as well the temperature was enough to softening the composite, making debonding bracket easier. In this part it was used 30 lower premolar recently extracted, and each one received 4 irradiations with different protocols, randomly choose. It was tested 12 different protocols varying time of irradiation (3 and 5s), pulse duration (0,01s e 0,03s) and power (5, 8 and 10W). Each protocol was repeated for 10 times (n=10), resulting 120 irradiations. In every irradiation the teeth tested were immerse in warm water bath at 37o C. It was found 4 protocols with pulp temperature lower than 5,5º C, so this is compatible with pulp health. In the second phase of this study, the objective was to evaluate the shear bond strength after laser irradiation, using the protocols with pulp chamber temperatures lower than 5,5º C. Seventy-five lower human premolars was shared in 5 groups. One group did not receive laser irradiation and considered Control (C) and the other groups the irradiation was made as it follows: Group I (power density 5W; pulse duration 0,01s; irradiation time 3s), Group II (5W; 0,03s, 3s), Group III (8W; 0,01s; 3s) and Group IV (10W; 0,01s; 3s). After results ANOVA and Tukey tests were made. Group IV presented lowering in SBS force (7,33 MPa) when compared with C (10,81MPa). This protocol was founded as a safe and efficient in softening composite layer.
7

Avaliação de diversos métodos para remoção da resina remanescente após descolagem de bráquetes ortodônticos

Cabral, Fátima Gouveia January 2006 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T17:11:38Z No. of bitstreams: 1 Dissertação - Fatima Cabral.pdf: 3063741 bytes, checksum: 2fef60738a8888a178499680d9647e2d (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T12:35:58Z (GMT) No. of bitstreams: 1 Dissertação - Fatima Cabral.pdf: 3063741 bytes, checksum: 2fef60738a8888a178499680d9647e2d (MD5) / Made available in DSpace on 2013-05-08T12:35:58Z (GMT). No. of bitstreams: 1 Dissertação - Fatima Cabral.pdf: 3063741 bytes, checksum: 2fef60738a8888a178499680d9647e2d (MD5) Previous issue date: 2006 / O objetivo deste estudo foi avaliar as alterações na superfície do esmalte, decorrentes da utilização de 5 técnicas distintas para a remoção da resina remanescente após a descolagem de bráquetes ortodônticos. Foram analisados 50 pré-molares humanos, extraídos por fins ortodônticos e periodontais, cujas faces vestibulares foram submetidas à análise rugosimétrica de superfície, executada em 3 momentos distintos: 1- inicial; 2- após a colagem, remoção de bráquetes e eliminação da resina remanescente; 3- após o polimento final. Nos grupos 1 e 2, utilizou-se a broca carbide de tungstênio em baixa e alta rotação, respectivamente. Para os grupos 3 e 4, o instrumento empregado foi a broca carbide de tungstênio proposta por Radlanski, também em baixa e alta rotação, respectivamente. Nestes 4 primeiros grupos, o polimento consistiu na utilização de discos de óxido de alumínio de granulação superfina. O grupo 5 foi representado pela associação de alicate removedor de resina e ponta de carboneto de silício em alta rotação, seguidos por polimento com pontas de borracha com grânulos de diamante em baixa rotação. Os resultados demonstraram que, após a remoção da resina, os menores valores de rugosidade superficial foram obtidos com a utilização da broca carbide de tungstênio em baixa rotação (grupo 1) e com as brocas propostas por Radlanski, tanto em baixa (grupo 3) quanto em alta rotação (grupo 4). Já a broca carbide de tungstênio em alta rotação (grupo 2) e o alicate removedor de resina associado às pontas de carboneto de silício e borracha (grupo 5)apresentaram valores de rugosidade média estatisticamente superiores aos demais grupos. Com o polimento, passou a existir diferença estatisticamente significante apenas em relação ao grupo 5, o qual revelou maior rugosidade do que os demais. A avaliação visual foi realizada por 3 examinadores e não detectou diferença estatisticamente significante entre os métodos utilizados. A partir destes dados, concluiu-se que a broca carbide de tungstênio em baixa rotação (grupo 1) e as brocas propostas por Radlanski (grupos 3 e 4) representaram métodos menos agressivos ao esmalte dentário para a remoção da resina remanescente após a descolagem de bráquetes. / Salvador