• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Jämförelse av portrycksmätning i Uppsalalera mellan portrycksmätare och dissipationstest

Ahlgren Mattsson, David January 2019 (has links)
Portrycket är en viktig parameter för att bestämma jordens egenskaper, såsom dränering, permeabilitet och stabilitet (då portrycket har en påverkan på den effektiva spänningen i jorden). Portrycket kan mätas med portrycksmätare men det kan även mätas under ett Cone penetrating test (CPT) med ett s.k. dissipationstest. Fördelar med ett dissipationstest jämfört med traditionell portrycksmätning skulle vara att det skulle spara tid och pengar, då man slipper trycka ner portrycksmätare och sedan vänta på att få portrycket ifrån dem, istället kan portrycket mätas under sondering med CPT.Detta självständiga arbete har som syfte att jämföra portrycksmätningar mellan portrycksmätning med BAT-spets och dissipationstest under CPT-sondering för att se hur bra mätvärden dissipationstester ger och om de eventuellt kan ersätta portrycksmätare. Fältförsöken av metoderna skedde i Uppsalalera, på en tomt i Kungsängen i Uppsala.Två stationer med BAT-spetsar på 5 meter, 7,5 meter och 10 meters djup sattes ner i leran. Sondering med CPT genomfördes sedan, där borren stoppades på samma djup som BAT-spetsarna. CPT:n stoppades på dessa djup i drygt 24 timmar, för att tillåta det generade portrycket som skapades när borren trycks ner i leran att skingras åt sidan. Jämviktsportrycket kommer vara det portryck som finns kvar efter att det generade portrycket har försvunnit. Portrycken från de två olika metoderna jämfördes sedan för att se hur nära dissipationstestet kommer värdena från portrycksmätningen med BAT-spetsarna.Resultatet av dissipationstesterna blev att inga av dem nådde referensvärdena från BAT-spetsarna efter 24 timmar. Beroende på användningsklass ligger dissipationstesterna inom den tillåtna minsta noggrannheten. Dissipationstest är antagligen inte så praktiskt tillämpbart i jordar med låg permeabilitet. / The pore pressure is an important parameter for determining the properties of thesoil, such as drainage, permeability and stability (since the pore pressure has aneffect on the effective stress in the soil). The pore pressure can be measured withpore pressure gauges but it can also be measured during a Cone penetration test(CPT) with a dissipation test. Advantages of a dissipation test compared tomeasurement with traditional pore pressure gauges would be that it would save timeand money, since you don’t have to press down pore pressure gauges and then waitto get the pore pressure from them, instead the pore pressure can be measuredduring probing with CPT.The purpose of this project is to compare pore pressure measurements betweenpore pressure measurements with BAT-tips and dissipation test during CPT probing,to see how good measured values the dissipation tests will provide and if theyeventually can supersede pore pressure gauges for pore pressure measurements.The field tests of the methods were done in Uppsala clay, on a site in Kungsängen inUppsala.Two stations with BAT-tips at 5 meters, 7.5 meters and 10 meters depth wereinstalled in the clay. Probing with CPT was then carried out, by stopping the CPT atthe same depth as the BAT-tips. Measurements with the CPT were done at thesedepths for just over 24 hours, to allow the generated excess pore pressure createdwhen the cone is pushed into the clay to disperse to the sides. The equilibrium porepressure is the pore pressure that remains after the generated pore pressure hasdissipated. The pore pressure from the two different methods was then compared tosee how close the dissipation test results were to the values from the pore pressuremeasurements with the BAT tips.The result of the dissipation tests was that none of them reached the referencevalues from the BAT-tips after 24 hours. Depending on the chosen application class,the dissipation tests are within the permitted minimum accuracy. Dissipation tests areprobably not practically applicable to soils with low permeability.

Page generated in 0.1071 seconds