• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • Tagged with
  • 32
  • 15
  • 15
  • 14
  • 14
  • 12
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo da luminescência de cristais de quartzo naturais e artificiais crescidos pelo método sol-gel. / Study of the luminescence of natural and artificial quartz crystals grown by the sol-gel method.

Tudela, Diego Renan Giglioti 28 November 2018 (has links)
Este trabalho foi dividido em duas grandes partes principais, a primeira relacionada ao estudo da luminescência de quatro espécimes de quartzo naturais brasileiros (verde, hialino, rosa e azul) e a segunda trata da confecção e caracterização de amostras sintéticas, baseadas na estrutura do SiO2, obtidas pelo método de sol-gel para fins de dosimetria das radiações ionizantes ambientais. Através da Análise por Ativação com Nêutrons Instrumental (AANI) e Fluorescência de Raios X por Reflexão Total (TXRF), foram determinadas as principais impurezas em concentrações maiores, menores e traços de forma quantitativa e qualitativa, respectivamente. Os espécimes verde e azul foram os que apresentaram as maiores quantidades de impurezas, incluindo metais e elementos terras raras, enquanto que o hialino e rosa são praticamente puros. Suas emissões de TL foram distintas, em termos de intensidade e posição dos picos. Testes de recuperação de dose por luminescência opticamente estimulada (LOE), através dos protocolos de alíquotas múltiplas (MAR) e única (SAR) com doses regenerativas, foram realizados e o espécime verde foi o único que apresentou resultados satisfatórios nesses testes, seguido do azul. Os cristais hialino e rosa apresentaram saturação e curva de crescimento fora da linearidade, onde o primeiro mostrou o efeito da fototransferência para a maioria das análises de SAR. Como os cristais verde e hialino apresentaram resultados opostos, em termos de quantidades de impurezas e emissões luminescentes, foi realizado um tratamento térmico em alta temperatura (1600 °C) para observar o efeito da mudança de fase (cristobalita) nas suas emissões luminescente. Ajustes teóricos das curvas de emissão de LOE contínua, linearmente modulada e TL mostraram que elas seguem o modelo teórico de cinéticas de ordens gerais. Na segunda parte deste trabalho, 32 amostras artificiais, do polimorfo de alta temperatura do quartzo, a cristobalita, foram sintetizadas com diferentes quantidades e tipos de dopantes, baseado nas impurezas determinadas no quartzo verde, utilizando duas rampas de aquecimento nas calcinações (3 e 15 °C/min). Essa parte do trabalho teve como finalidade o estudo do efeito do Fe na emissão luminescente das amostras sintéticas, a reprodução de uma das amostras naturais e produção e caracterização de dosímetros para radiações ionizantes ambientais. A utilização das duas rampas de aquecimento na emissão de TL, de forma geral, não desempenhou papel determinante na intensidade dos picos de altas temperaturas. Já na LOE foi observado que as amostras calcinadas com a rampa de maior temperatura apresentaram resposta à dose mais elevadas. O Fe como dopante em maior quantidade atuou como um inibidor de luminescência tanto na TL quanto na LOE. Uma amostra com características qualitativas semelhante ao quartzo verde, na fase da cristobalita, foi obtida com relativo sucesso utilizando como dopante todas as doze principais impurezas adquiridas para realização deste projeto. Quatro amostras foram sintetizadas com diferentes tipos e quantidades de dopantes para aplicação em dosimetria das radiações. Somente uma destas apresentou resposta linear às doses de radiação utilizando estimulação térmica (TL), cuja mínima dose de detecção (MDD) foi de 172 µGy. Utilizando estimulação óptica (LOE), duas amostras apresentaram comportamento linear com as doses de radiação, em que valores de MDD de ~440 µGy e 405 µGy foram obtidos. / This work was divided into two major parts, the first one related to the study of the luminescence of four Brazilian natural quartz specimens (green, hyaline, pink and blue) and the second one deals with the confection and characterization of synthetic samples, based on SiO2 structure, obtained by means of sol-gel method to environmental ionizing radiation dosimetry. Through Instrumental Neutron Activation Analysis (INAA) and Total Reflection X-ray Fluorescence (TXRF), the main impurities in major, minor and trace concentrations were determined quantitative and qualitatively respectively. The green and blue specimens presented the highest amounts of impurities, including metals and rare earth elements, whereas hyaline and pink are practically pure. Their TL emissions were distinct, in terms of intensity and peak position. OSL dose recovery tests, using multiple (MAR) and single aliquots regeneration (SAR) dose protocols were performed and the green specimen was the only one which presented satisfactory results in these tests, followed by blue. The hyaline and pink crystals showed saturation and growth curve out of linearity, where the first one showed the effect of phototransference for most SAR analysis. As green and hyaline crystals presented opposite results, in terms of impurities quantities and luminescent emissions, a high temperature (1600 °C) heat treatment was performed to observe the effect of the phase change (cristobalite) on its luminescent emissions. Theoretical adjustments of the CW-OSL, LM-OSL and TL emission curves showed that they follow the theoretical model of general order kinetics. In the second part of this work, 32 artificial samples of the high temperature polymorph of the quartz, cristobalite, were synthesized with different amounts and types of dopants, based on impurities determined in green quartz, making use of two heating rates in the calcinations (3 and 15 °C/min). This part of the work had as purpose the study of the effect of Fe in the luminescent emission of the synthetic samples, the reproduction of one of the natural samples and production and characterization of dosimeters for environmental ionizing radiation. The use of the two heating rates in TL emission, in general, did not play a determining role in the intensity of the high temperature peaks. In the OSL, it was observed that samples calcined with higher heating rate temperature showed higher response to dose. The Fe as a dopant in greater quantities acted as a quencher of luminescence both in TL and OSL. A sample with qualitative characteristics similar to the green quartz, in the cristobalite phase, was obtained with relative success using as dopants all the twelve main impurities acquired for this project. Four samples were synthesized with different types and amounts of dopants for application in ionizing radiation dosimetry. Only one of these showed a linear response to radiation doses using thermal stimulation (TL), with a minimum detectable dose (MDD) of 172 µGy. Using optical stimulation (OSL), two samples showed linear behavior with radiation doses, in which MDD values of ~440 µGy and 405 µGy were obtained.
12

Validação e avaliação dosimétrica empregando as técnicas de TL e OSL de materiais termoluminescentes para aplicação na dosimetria de feixes clínicos de elétrons utilizados na irradiação total da pele - TSI / Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI

Almeida, Shirlane Barbosa de 11 April 2017 (has links)
A dosimetria in vivo têm se tornado um papel importante para o tratamento da irradiação total da pele dentro de um rigoroso programa de garantia de qualidade que deve ser parte integrante nos departamentos radioterápicos. A dosimetria em TSI é difícil, devido à complexidade do tratamento em avaliar a uniformidade da dose e medir a dose absorvida em profundidades rasas em toda extensão da superfície cutânea, tendo como consequência uma ampla variação na distribuição da dose. Os TLDs tem provado ser muito úteis para a distribuição e verificação da dose prescrita para o paciente, pois a dose pode diferir de local para local devido a geometria do corpo do paciente, sobreposições de estruturas e assimetrias do campo de radiação. A utilização de TLDs in vivo pode identificar variações da dose prescrita por apresentarem uma grande exatidão e precisão nas medidas. Nos setores de radioterapia vêm sendo empregado vários tipos de dosímetros, os mais utilizados são o Flureto de Lítio (TLD-100), onde obtém uma longa história neste tipo de aplicação. Novos materiais dosímetricos vêm ganhado grande importância na aplicação da dosímetria de feixes clínicos de elétrons, como o Sulfato de Cálcio dopado com Disprósio (TL) e o Óxido de Alumínio dopado com Carbono (OSL), este trabalho avalia o desempenho dosímetrico dos respectivos dosímetros termoluminescentes e a luminescência opticamente estimulada na aplicação da dosímetria de feixes clínicos de elétrons utilizados na irradiação total da pele. / In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin.
13

Estudo da luminescência de cristais de quartzo naturais e artificiais crescidos pelo método sol-gel. / Study of the luminescence of natural and artificial quartz crystals grown by the sol-gel method.

Diego Renan Giglioti Tudela 28 November 2018 (has links)
Este trabalho foi dividido em duas grandes partes principais, a primeira relacionada ao estudo da luminescência de quatro espécimes de quartzo naturais brasileiros (verde, hialino, rosa e azul) e a segunda trata da confecção e caracterização de amostras sintéticas, baseadas na estrutura do SiO2, obtidas pelo método de sol-gel para fins de dosimetria das radiações ionizantes ambientais. Através da Análise por Ativação com Nêutrons Instrumental (AANI) e Fluorescência de Raios X por Reflexão Total (TXRF), foram determinadas as principais impurezas em concentrações maiores, menores e traços de forma quantitativa e qualitativa, respectivamente. Os espécimes verde e azul foram os que apresentaram as maiores quantidades de impurezas, incluindo metais e elementos terras raras, enquanto que o hialino e rosa são praticamente puros. Suas emissões de TL foram distintas, em termos de intensidade e posição dos picos. Testes de recuperação de dose por luminescência opticamente estimulada (LOE), através dos protocolos de alíquotas múltiplas (MAR) e única (SAR) com doses regenerativas, foram realizados e o espécime verde foi o único que apresentou resultados satisfatórios nesses testes, seguido do azul. Os cristais hialino e rosa apresentaram saturação e curva de crescimento fora da linearidade, onde o primeiro mostrou o efeito da fototransferência para a maioria das análises de SAR. Como os cristais verde e hialino apresentaram resultados opostos, em termos de quantidades de impurezas e emissões luminescentes, foi realizado um tratamento térmico em alta temperatura (1600 °C) para observar o efeito da mudança de fase (cristobalita) nas suas emissões luminescente. Ajustes teóricos das curvas de emissão de LOE contínua, linearmente modulada e TL mostraram que elas seguem o modelo teórico de cinéticas de ordens gerais. Na segunda parte deste trabalho, 32 amostras artificiais, do polimorfo de alta temperatura do quartzo, a cristobalita, foram sintetizadas com diferentes quantidades e tipos de dopantes, baseado nas impurezas determinadas no quartzo verde, utilizando duas rampas de aquecimento nas calcinações (3 e 15 °C/min). Essa parte do trabalho teve como finalidade o estudo do efeito do Fe na emissão luminescente das amostras sintéticas, a reprodução de uma das amostras naturais e produção e caracterização de dosímetros para radiações ionizantes ambientais. A utilização das duas rampas de aquecimento na emissão de TL, de forma geral, não desempenhou papel determinante na intensidade dos picos de altas temperaturas. Já na LOE foi observado que as amostras calcinadas com a rampa de maior temperatura apresentaram resposta à dose mais elevadas. O Fe como dopante em maior quantidade atuou como um inibidor de luminescência tanto na TL quanto na LOE. Uma amostra com características qualitativas semelhante ao quartzo verde, na fase da cristobalita, foi obtida com relativo sucesso utilizando como dopante todas as doze principais impurezas adquiridas para realização deste projeto. Quatro amostras foram sintetizadas com diferentes tipos e quantidades de dopantes para aplicação em dosimetria das radiações. Somente uma destas apresentou resposta linear às doses de radiação utilizando estimulação térmica (TL), cuja mínima dose de detecção (MDD) foi de 172 µGy. Utilizando estimulação óptica (LOE), duas amostras apresentaram comportamento linear com as doses de radiação, em que valores de MDD de ~440 µGy e 405 µGy foram obtidos. / This work was divided into two major parts, the first one related to the study of the luminescence of four Brazilian natural quartz specimens (green, hyaline, pink and blue) and the second one deals with the confection and characterization of synthetic samples, based on SiO2 structure, obtained by means of sol-gel method to environmental ionizing radiation dosimetry. Through Instrumental Neutron Activation Analysis (INAA) and Total Reflection X-ray Fluorescence (TXRF), the main impurities in major, minor and trace concentrations were determined quantitative and qualitatively respectively. The green and blue specimens presented the highest amounts of impurities, including metals and rare earth elements, whereas hyaline and pink are practically pure. Their TL emissions were distinct, in terms of intensity and peak position. OSL dose recovery tests, using multiple (MAR) and single aliquots regeneration (SAR) dose protocols were performed and the green specimen was the only one which presented satisfactory results in these tests, followed by blue. The hyaline and pink crystals showed saturation and growth curve out of linearity, where the first one showed the effect of phototransference for most SAR analysis. As green and hyaline crystals presented opposite results, in terms of impurities quantities and luminescent emissions, a high temperature (1600 °C) heat treatment was performed to observe the effect of the phase change (cristobalite) on its luminescent emissions. Theoretical adjustments of the CW-OSL, LM-OSL and TL emission curves showed that they follow the theoretical model of general order kinetics. In the second part of this work, 32 artificial samples of the high temperature polymorph of the quartz, cristobalite, were synthesized with different amounts and types of dopants, based on impurities determined in green quartz, making use of two heating rates in the calcinations (3 and 15 °C/min). This part of the work had as purpose the study of the effect of Fe in the luminescent emission of the synthetic samples, the reproduction of one of the natural samples and production and characterization of dosimeters for environmental ionizing radiation. The use of the two heating rates in TL emission, in general, did not play a determining role in the intensity of the high temperature peaks. In the OSL, it was observed that samples calcined with higher heating rate temperature showed higher response to dose. The Fe as a dopant in greater quantities acted as a quencher of luminescence both in TL and OSL. A sample with qualitative characteristics similar to the green quartz, in the cristobalite phase, was obtained with relative success using as dopants all the twelve main impurities acquired for this project. Four samples were synthesized with different types and amounts of dopants for application in ionizing radiation dosimetry. Only one of these showed a linear response to radiation doses using thermal stimulation (TL), with a minimum detectable dose (MDD) of 172 µGy. Using optical stimulation (OSL), two samples showed linear behavior with radiation doses, in which MDD values of ~440 µGy and 405 µGy were obtained.
14

Correção de heterogeneidades para feixes de fótons de 6 MeV: comparações entre algoritmos de cálculo e medidas com TLD

Baptista, Cláudia Gonçalves 25 September 2009 (has links)
O presente trabalho mostra as diferenças de dose encontradas em meios de diferentes densidades eletrônicas, simulando tecido adiposo, muscular, ósseo e cavidade aérea, comparando medidas experimentais com feixe de fótons de 6 MeV e valores resultantes de algoritmos de cálculo existentes em um sistema de planejamento radioterápico. Para isso foram utilizados dosímetros termoluminescentes posicionados acima, dentro e abaixo de cada objeto simulador e medidos os perfis de dose ao longo do eixo longitudinal e do eixo transversal. As simulações computacionais foram realizadas com dois algoritmos de cálculo presentes na versão 8.5 do sistema de planejamento Eclipse: o Pencil Beam Convolution e o Analytical Anisotropic Algorithm. Comparando doses em um mesmo ponto, com e sem heterogeneidades, foram encontradas diferenças percentuais de até 12%, quando os algoritmos de correção de heterogeneidades não foram aplicados. Analisando essas comparações, pode-se observar também qual dos algoritmos de cálculo mais se aproxima dos valores experimentais, propondo ser o algoritmo de maior confiabilidade. / This work presents the dose variations obtained when phantoms of different electronic densities were used, simulating fat tissue, muscle, bones and air cavities, comparing experimental data with a 6 MeV photon beams and the values calculated by the treatment planning system algorithms. Thermoluminescent dosimeters were positioned above, inside and below each phantom measuring the dose along the depth and along a profile. The computational simulation was done by two algorithms that are part of Eclipse version 8.5: Pencil Beam Convolution and Analytical Anisotropic Algorithm. Comparing doses at the same point, with and without heterogeneities, percentages of 12% were found when heterogeneity correction was not used. These results also show which of the algorithms approaches better to the experimental values, becoming more reliable.
15

Validação e avaliação dosimétrica empregando as técnicas de TL e OSL de materiais termoluminescentes para aplicação na dosimetria de feixes clínicos de elétrons utilizados na irradiação total da pele - TSI / Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI

Shirlane Barbosa de Almeida 11 April 2017 (has links)
A dosimetria in vivo têm se tornado um papel importante para o tratamento da irradiação total da pele dentro de um rigoroso programa de garantia de qualidade que deve ser parte integrante nos departamentos radioterápicos. A dosimetria em TSI é difícil, devido à complexidade do tratamento em avaliar a uniformidade da dose e medir a dose absorvida em profundidades rasas em toda extensão da superfície cutânea, tendo como consequência uma ampla variação na distribuição da dose. Os TLDs tem provado ser muito úteis para a distribuição e verificação da dose prescrita para o paciente, pois a dose pode diferir de local para local devido a geometria do corpo do paciente, sobreposições de estruturas e assimetrias do campo de radiação. A utilização de TLDs in vivo pode identificar variações da dose prescrita por apresentarem uma grande exatidão e precisão nas medidas. Nos setores de radioterapia vêm sendo empregado vários tipos de dosímetros, os mais utilizados são o Flureto de Lítio (TLD-100), onde obtém uma longa história neste tipo de aplicação. Novos materiais dosímetricos vêm ganhado grande importância na aplicação da dosímetria de feixes clínicos de elétrons, como o Sulfato de Cálcio dopado com Disprósio (TL) e o Óxido de Alumínio dopado com Carbono (OSL), este trabalho avalia o desempenho dosímetrico dos respectivos dosímetros termoluminescentes e a luminescência opticamente estimulada na aplicação da dosímetria de feixes clínicos de elétrons utilizados na irradiação total da pele. / In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin.
16

Estrutura eletrônica do polímero orgânico conjugado MEH-PPV em solução sob radiação ionizante /

Batagin Neto, Augusto. January 2009 (has links)
Orientador: Francisco Carlos Lavarda / Banca: Carlos Frederico de Oliveira Graeff / Banca: Paulo Monteiro Vieira Braga Barone / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: Os polímeros orgânicos conjugados têm sido amplamente utilizados em diversos campos tecnológicos devido às suas características semicondutoras e ópticas. Recentemente foi relatada a possibilidade de sua utilização na área de dosimetria. O polímero MEH-PPV, quando diluído em solventes que contenham halogênios, tem apresentado características bastante promissoras nesta área, contudo não há ainda uma completa compreensão dos mecanismos envolvidos. No presente trabalho realizou-se o estudo conformacional e da estrutura eletrônica do polímero MEH-PPV em clorofórmio e as possíveis alterações provenientes da irradiação desta solução com radiações ionizantes. Métodos de modelagem de materiais foram utilizados a fim de simular o sistema. Resultados experimentais sugerem que os efeitos observados são oriundos da interação do solvente com a cadeia polimérica. A fim de investigar tal possibilidade, uma análise dos prováveis sítios de maior reatividade sobre o polímero foi realizada, apontando um mecanismo de incorporação de radicais sobre a cadeia principal. / Abstract: Organic conducting polymers have been employed in several technological fields due to its semiconducting and optical properties. Recently, several reports points to applications in radiation dosimetry. When diluted in halogen-containing solvents, the polymer MEH-PPV shows interesting properties after gamma irradiation. Despite the promising application, still is lacking a complete understanding of the underlying phenomena. In the present work, we studied the geometry conformation and electronic structure of MEH-PPV in the presence of chloroform employing molecular modeling techniques to simulate the system. Several possibilities for polymer modification under gamma radiation were investigated, following suggestion from experimental results. Finally, a model for the color modifications of the solution is present. / Mestre
17

Produção e caracterização de dosímetros à base de magnésio

Souza, Luiza Freire de 13 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / With the purpose of obtain solid state dosimeters whith characteristics such as high sensitivity, ease obtaining and handling and that are practical and economical were studied in in the present work phosphors based on magnesium ion. The materials chosen for analysis were MgSO4 (magnesium sulphate) and MgB4O7 (magnesium tetraborate), both materials were doped with the rare earths Dy (dysprosium) and Tm (thulium). The interest in the production of these doped materials was to investigate the production of thermoluminescent dosimeters with these elements and study their thermoluminescence characteristics. The phosphors were obtained by acid solution. The thermoluminescence response of materials produced in pellet form were investigated. For the study of thermoluminescent characteristics, sulphate and tetraborate samples were irradiated with a beta source (90Sr+90Y). The thermoluminescence response of the pellets based on MgB4O7 were investigate in more details after exposure to different radiation sources such as X rays , 60Co and 137Cs. For these materials the dose response curves related to X-rays and 60Co irradiations, reproducibility, homogeneity, minimum detectable dose, energy dependence, the intrinsic efficiency and the kinetic parameters for the glow curves, using Chen´s method were evaluated. The results obtained for MgB4O7:Dy and MgB4O7:Tm samples, show that is possible to use both materials to radiation dosimetry of photon beams such as X ray and gamma and beta radiation, due to the facility of the preparation , since they have adequate sensitivity and linearity of TL response over the dose range evaluated, among other characteristic. The initial studies of MgSO4: Dy (or Tm), show that materials have potential to dosimetry and should be better evaluated in future work. / Com o intuito de se obter dosímetros de estado sólido que apresentem características tais como: alta sensibilidade, facilidade de obtenção e manuseio, praticidade e economicidade foram estudados no presente trabalho fósforos à base do íon magnésio. Os materiais escolhidos para análise foram o MgSO4 (sulfato de magnésio) e o MgB4O7 (tetraborato de magnésio); ambos materiais foram impurificados com os terras raras Dy (disprósio) e Tm (túlio). O interesse na produção desses materiais impurificados foi o de investigar a produção de dosímetros termoluminescente com esses elementos e as características dessa termoluminescência. Os fósforos foram obtidos através de solução ácida. Foi investigada a resposta termoluminescente dos materiais produzidos na forma de pastilhas prensadas. Para o estudo das características termoluminescentes, amostras de sulfatos e tetraboratos foram irradiados com fonte beta (90Sr+90Y). A resposta termoluminescente das pastilhas produzidas à base de MgB4O7 foi investigada de forma mais aprofundada, após exposição a diferentes fontes de radiação, tais como, raios X , 60Co, e 137Cs. Para esse material, as respostas em função da dose de raios X e 60Co,a reprodutibilidade, a homogeneidade, a dose mínima detectável, a dependência energética, a eficiência intrínseca e os parâmetros cinéticos das curvas de emissão através do método de Chen, foram avaliadas. Os resultados obtidos para as amostras de MgB4O7:Dy e MgB4O7:Tm mostram que é possível a utilização de ambos materiais para dosimetria de feixes de radiações ionizantes, tais como feixes de fótons de raios X e radiações gama e beta, devido à facilidade de preparação, por apresentarem sensibilidade termoluminescente adequada e linearidade da resposta TL no intervalo de dose avaliado, entre outras características. Os estudos iniciais com MgSO4:Dy (ou Tm) indicam que esses apresentam potencial para dosimetria e por isso devem ser mais bem avaliados em trabalhos futuros.
18

Caracterização de polímeros semicondutores para o uso em sensores de radiação gama. / Characterization of semiconductor polymers for use in gamma radiation sensors.

Dayana Luiza Martins Bazani 15 May 2008 (has links)
Este trabalho tem por objetivo investigar as propriedades ópticas de sistemas poliméricos luminescentes submetidos a diferentes doses de radiação gama. Foram preparadas soluções de poli[2-metóxi-5-(2\'etil-hexilóxi)-p-fenilenovinileno] - MEHPPV em clorofórmio e filmes finos depositados a partir de soluções deste polímero sobre substrato de vidro. As soluções e filmes finos tiveram suas propriedades investigadas por meio de medidas de absorção ultravioleta-visível (UV-VIS). Os filmes finos também foram analisados por medidas de espectroscopia de infravermelho (FTIR) além da cromatografia HPSEC. Os resultados experimentais foram analisados buscando elucidar tanto os efeitos da radiação nas propriedades ópticas dos polímeros, como também o estudo da viabilidade destes materiais como elementos ativos de dosímetros para baixas doses de radiação gama (< 1 kGy) especialmente para aplicações no tratamento de esterilização de bolsas de sangue (~ 25 Gy) e altas doses de radiação gama (até 25 kGy) para aplicações como esterilização de materiais médicos hospitalares. / This work aims the investigation of the optical properties of luminescent polymeric systems when submitted to different gamma radiation doses. Solutions of poly[2-methoxi-5-(2\'etil-hexiloxi)-p-phenilenevinilene] - MEH-PPV in chloroform were prepared. From those solutions, thin film layers of MEH-PPV were deposited on glass substrates. The polymer solutions and the thin-film samples of MEHPPV had their properties investigated by ultraviolet-visible (UV-Vis) absorption spectroscopy. The thin-film prepared samples were, additionally, investigated by InfraRed Fourier Transform (FTIR) spectroscopy and HPSEC chromatography. The experimental results were investigated to elucidate the radiation effects on the optical properties of these polymeric systems. From the experimental results, the feasibility of using this material as active element in gamma radiation dosimeters was investigated. The research was conducted aiming the low dose gamma radiation (< 1 kGy) specifically for application in the sterilization treatment of blood bags (~ 25 Gy) and high gamma radiation doses (up to 25 kGy) as used for the sterilization of medical and hospital supplies.
19

Avaliação dosimétrica da solução fricke gel usando a técnica de espectrofotometria para aplicação na dosimetria de elétrons e nêutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

Mangueira, Thyago Fressatti 31 July 2009 (has links)
Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams.
20

Preparação por inkjet e caracterização de dosímetros poliméricos para radiação UV-azul. / Fabrication using inkjet and characterization of polymer radiation dosimeter for UV-blue.

Santos, Helton Almeida dos 26 May 2008 (has links)
Ao final da década de 1980, pesquisadores da empresa Eastman Kodak anunciaram as propriedades eletroluminescentes de materiais orgânicos não poliméricos. Seguindo essa linha, em 1990, um grupo de pesquisadores ingleses demonstrou propriedades semelhantes para os polímeros, utilizando-os como elementos ativos de dispositivos emissores de luz. Era este o início de uma nova área de pesquisa que tinha interface na eletrônica e nos novos semicondutores poliméricos. Surgiram os chamados polímeros luminescentes - resultado das descobertas das propriedades semicondutoras dos polímeros e copolímeros, blendas e heteroestruturas orgânico-inorgânicas. Os materiais semicondutores poliméricos apresentam diversas vantagens associadas à sua característica de fácil processamento e baixo custo de produção. Podem ser utilizados na forma de filmes finos que têm boas propriedades mecânicas e que permitem a sua utilização em substratos flexíveis. Diversas empresas como Philips, Sony, Pioneer, DuPont, Kodak e Uniax têm investido fortemente em pesquisa e desenvolvimento de dispositivos eletroluminescentes, memórias, sensores de imagem e outros sensores que aproveitam as propriedades dos polímeros semicondutores. A radiação, numa variada faixa de comprimentos de onda, pode afetar as propriedades de alguns desses polímeros semicondutores. A característica de material semicondutor, inerente a esses materiais, pode ser degradada por efeito de foto-oxidação que pode ser estimulado pela exposição à radiação. Surge a possibilidade de desenvolver dispositivos baseados em polímeros semicondutores para uso em detectores de radiação. Este trabalho consiste num estudo de desenvolvimento de dosímetros poliméricos de radiação para a faixa de comprimento de onda entre 400 nm e 500 nm, especificamente usada em ambientes hospitalares no tratamento intensivo de neonatos. Com o objetivo descrito, foi realizado o estudo de substratos adequados para a finalidade desejada, o desenvolvimento de um processo de deposição para os dispositivos de filmes-finos e o estudo da influência da radiação na faixa do ultravioleta-visível (UV-Vis) em suas propriedades. Das diversas técnicas de deposição de filmes finos existentes, foi selecionada para este estudo, a de deposição por jato de tinta (\"inkjet printing\") devido às suas características de simplicidade, potencial custo baixo e, principalmente, o menor nível de perda do polímero a ser depositado, já que a referida técnica permite a deposição de quantidades mínimas do material. Como material ativo foi selecionado um semicondutor polimérico da família dos polifluorenos, devido ao seu relativamente fácil manuseio. Pesquisadores da área, cada vez mais, acreditam que a impressão por jato de tinta seja uma das técnicas de deposição mais promissoras para a produção em grande escala. O objetivo desta pesquisa é contribuir com um novo instrumento a ser usado no monitoramento da irradiação no tratamento fototerápico da hiperbilirrubinemia no ambiente da neonatologia hospitalar. Atualmente os bebês recém-nascidos são tratados com empirismo considerável tendo em conta não haver procedimentos de controle para a dose da irradiação aplicada ao neonato nas incubadora neonatal das maternidades. Os riscos de hiperbilirrubinemia severa do neonato incluem a possibilidade de surdez, de paralisia cerebral ou mesmo de lesão cerebral em casos extremos. A observada Icterícia pode estar ligada à imaturidade do fígado do bebê. A bilirubinemia é muito freqüente em neonatos e precisa ser tratada para a redução dos citados riscos. O tratamento mais comum é a fototerapia com radiação na faixa do UV-próximo/azul. A fototerapia é realizada por várias sessões de muitas horas que dependem do nível de hiperbilirrubinemia no sangue, TBS (Total Bilirrubine Serum) do bebê. A hiperbilirrubinemia é crítica quando seu nível for igual ou maior que 428 micromol/litro ou 25 mg/dL (Referencia - Previsão e prevenção de hiperbilirrubinemia de neonatal extremo, T.B., Newman et al., Arco Pediatr Adolesc Med/Vol 154, Nov. 2000 pp 1140-1147). Além de permitir reduzir o empirismo do tratamento com o uso de um dosímetro para a faixa de radiação em tela, este pode ser usado para avaliar a condição da fonte de radiação específica de luz usada neste tipo de tratamento. O dosímetro proposto, como instrumento adicional para os neonatologistas poderá monitorar as doses de radiação aplicada durante a fototerapia e evitar excessos, reduzindo o tempo no protocolo de tratamento neonatal. / At the end of the 1980s, researchers from Eastman Kodak announced the electroluminescent properties of non-polymeric organic materials. At the beginning of the 1990s, researchers from the UK showed similar properties of organic polymers, using them as active elements in light emitting devices. It was the beginning of a new research area interfacing the electronics and the new polymeric semiconductors. As a result of the findings on the semiconducting properties of polymers and copolymers, blends and organic-inorganic heterostructures, a new class of materials became the research subject of several groups. Polymer semiconductors exhibit several advantages like simple processing and low production cost. They can be utilized as thin-films with good mechanical properties for use in flexible substrates. Several high-tech enterprises like Philips, Sony, Pioneer, DuPont, Kodak and Uniax are investing strongly in the research and development of such materials and devices, including memories, image sensors, light-emmiting devices, among others. Radiation in a very broad range of wavelengths can affect characteristics of some semiconductor polymers. Their inherent semiconducting feature can be degraded by the photo-oxidation effect, activated by radiation exposition. This suggests the possibility of the development of semiconductor polymer based radiation sensing devices. This work deals with a study of radiation dosimeters for the wavelength range of 400 nm to 500 nm, specifically important at the maternity hospitals in the therapy of newborn babies. To cope with this objective, the study of adequate substrates, development of suitable deposition process for the thin-film devices and study of its properties changes with radiation in the ultraviolet-visible (UV-Vis) range was done. From the different thin-film deposition techniques, the inkjet deposition technique was selected for this study thanks to its production simplicity, potential low cost an, mainly, because it permits the deposition of minute amounts of material, leading to very little material losses. As the active material a polymeric semiconductor of the fluorene family was selected thanks to its easy processing. Researchers of this area, more and more, believe that the Inkjet Printing is one of the very promising deposition techniques for mass production of those devices. The aim of this research is to offer a new tool to be used in the monitor of the irradiation in the phototherapy for severe hyperbilirubinemia of newborn babies. In most cases newborn babies are treated with a considerably empiric protocol considering the inexistence of procedures to control the radiation doses in the treatments. The risks of extreme neonatal hyperbilirubinemia include possibility of deafness, cerebral palsy or brain damage in extreme cases. Jaundice may be due to the immaturity of baby\'s liver. Bilirubinemia is most frequent in newborn and must be treated to reduce such risks. The most common treatment is phototherapy with nearUV-blue radiation. Phototherapy is accomplished by several sessions of many hours depending on the Total Bilirubin Serum (TBS) found in the baby blood. Hyperbilirubinemia is very dangerous to the near-term newborn when its level is equal or greater than 428 micromol/liter or 25 mg/dL (Reference Prediction and prevention of extreme neonatal hyperbilirubinemia, T.B., Newman et al., Arch Pediatr Adolesc Med/Vol 154, Nov. 2000 pp 1140-1147). Besides reducing the empiric treatments based on the nearUV-blue radiation, the use of a sensor can be important to evaluate the condition of the specific type of lamp used in the treatments. The proposed dosimeter can be an additional instrument for the neonatologists to be used in the determination of the phototherapy radiation dose, thus reducing, in the medical protocol, the jaundice treatment time.

Page generated in 0.0598 seconds