• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • Tagged with
  • 32
  • 15
  • 15
  • 14
  • 14
  • 12
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação dosimétrica da solução fricke gel usando a técnica de espectrofotometria para aplicação na dosimetria de elétrons e nêutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

Thyago Fressatti Mangueira 31 July 2009 (has links)
Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams.
22

Avaliação da qualidade da imagem e dose na paciente em mamografia analógica e digital

Santos, Amanda Cristina dos 30 August 2011 (has links)
Este trabalho foi motivado por um estudo maio, proposto pela Agência Internacional de Energia Atômica (IAEA). O objetivo do trabalho foi estimar o kerma incidente (Ki) e a dose glandular média (Dg) em pacientes submetidas a mamografias nas projeções crânio-caudal (CC) e médio-lateral-oblíqua (MLO), nos sistemas de aquisição de imagens analógico e digital CR. A estimativa foi realizada através de cálculos matemáticos, tendo como base estudos computacionais utilizando simulações de Monte Carlo. Este estudo fez parte de um estudo maior em mamografia, coordenado pela IAEA, cujos dados fizeram parte da representação dos dados brasileiros no estudo da América Latina. Foram escolhidas mamografias cuja mama exposta tinha aproximadamente 50% de glandularidade e 50% de adiposidade. Dados da técnica radiográfica utilizada nos exames, assim como a espessura da mama comprimida, foram registrados em planilhas especificas e o cálculo foi realizado com base em testes de rendimento do tubo de raios X dos mamógrafos. Além disso, as mamografias acompanhadas foram analisadas quanto a critérios de qualidade da imagem. Foram acompanhadas 100 exposições, sendo 50 analógicas e d 50 digitais. Os resultados mostraram que as imagens foram predominantemente aceitas quanto aos critérios de qualidade da imagem estabelecidos pala IAEA, com melhores resultados do sistema digital. Os valores de Ki e Dg encontrados para o objeto simulador estavam de acordo com o recomendado, mas os calculados para as pacientes estavam mais altos, principalmente o Ki. O sistema digital obteve doses mais baixas e melhor qualidade de imagem. Os resultados sugerem que os exames devem ser realizados com o devido cuidado, de maneira a oferecer qualidade de imagem para o diagnóstico em doses tão baixas quanto razoavelmente exeqüíveis. O treinamento contínuo dos profissionais da mamografia deve ser realizado de maneira e oferecer exames adequados ao diagnóstico, protegendo os pacientes e mantendo a qualidade do serviço a todos. / This work has been motivated by a larger study, proposed by the International Atomic Energy Agency (IAEA). The aim of this work was to estimate the incident kerma (Ki) and mean glandular dose (Dg) in patients who underwent mammograms in craniocaudal projections (CC) and mediolateral-ablique (MLO), at analog and digital systems. The estimation was performed using mathematical calculations based on computational studies using Monte Carlo simulations. This study was part of a larger study in mammography, coordinated by the IAEA, whose data were included in the representation of Brazilian data in the study of Latin America. Mammograms with 50% of glandular tissue and 50% of fat were selected. Data from the radiographic technique used in the examinations, as well as the compressed breast thickness were recorded in spreadsheets and specific calculation was made based on output tests of the X-ray tube for mammography. In addition, the mammograms were analysed with the criteria of image quality. The amount of examinations was 100 mammograms, 50 analog and 50 digital. The results showed that the images were largely accepted as the criteria for image quality established by the IAEA, with better results from digital system. The values of Ki and Dg for the phantom were according to the recommended, but those calculate for the patients were higher, especially the Ki. Digital system produced lower dosis and better results on image quality. The results suggests that the examinations must be conducted with due care in order to offer image quality in dosis as low as reasonably achievable. The permanent training of mammographers should be conducted in a manner to provide exams with quality, protecting the patient and maintaining the quality of service to all patients treated.
23

Preparação por inkjet e caracterização de dosímetros poliméricos para radiação UV-azul. / Fabrication using inkjet and characterization of polymer radiation dosimeter for UV-blue.

Helton Almeida dos Santos 26 May 2008 (has links)
Ao final da década de 1980, pesquisadores da empresa Eastman Kodak anunciaram as propriedades eletroluminescentes de materiais orgânicos não poliméricos. Seguindo essa linha, em 1990, um grupo de pesquisadores ingleses demonstrou propriedades semelhantes para os polímeros, utilizando-os como elementos ativos de dispositivos emissores de luz. Era este o início de uma nova área de pesquisa que tinha interface na eletrônica e nos novos semicondutores poliméricos. Surgiram os chamados polímeros luminescentes - resultado das descobertas das propriedades semicondutoras dos polímeros e copolímeros, blendas e heteroestruturas orgânico-inorgânicas. Os materiais semicondutores poliméricos apresentam diversas vantagens associadas à sua característica de fácil processamento e baixo custo de produção. Podem ser utilizados na forma de filmes finos que têm boas propriedades mecânicas e que permitem a sua utilização em substratos flexíveis. Diversas empresas como Philips, Sony, Pioneer, DuPont, Kodak e Uniax têm investido fortemente em pesquisa e desenvolvimento de dispositivos eletroluminescentes, memórias, sensores de imagem e outros sensores que aproveitam as propriedades dos polímeros semicondutores. A radiação, numa variada faixa de comprimentos de onda, pode afetar as propriedades de alguns desses polímeros semicondutores. A característica de material semicondutor, inerente a esses materiais, pode ser degradada por efeito de foto-oxidação que pode ser estimulado pela exposição à radiação. Surge a possibilidade de desenvolver dispositivos baseados em polímeros semicondutores para uso em detectores de radiação. Este trabalho consiste num estudo de desenvolvimento de dosímetros poliméricos de radiação para a faixa de comprimento de onda entre 400 nm e 500 nm, especificamente usada em ambientes hospitalares no tratamento intensivo de neonatos. Com o objetivo descrito, foi realizado o estudo de substratos adequados para a finalidade desejada, o desenvolvimento de um processo de deposição para os dispositivos de filmes-finos e o estudo da influência da radiação na faixa do ultravioleta-visível (UV-Vis) em suas propriedades. Das diversas técnicas de deposição de filmes finos existentes, foi selecionada para este estudo, a de deposição por jato de tinta (\"inkjet printing\") devido às suas características de simplicidade, potencial custo baixo e, principalmente, o menor nível de perda do polímero a ser depositado, já que a referida técnica permite a deposição de quantidades mínimas do material. Como material ativo foi selecionado um semicondutor polimérico da família dos polifluorenos, devido ao seu relativamente fácil manuseio. Pesquisadores da área, cada vez mais, acreditam que a impressão por jato de tinta seja uma das técnicas de deposição mais promissoras para a produção em grande escala. O objetivo desta pesquisa é contribuir com um novo instrumento a ser usado no monitoramento da irradiação no tratamento fototerápico da hiperbilirrubinemia no ambiente da neonatologia hospitalar. Atualmente os bebês recém-nascidos são tratados com empirismo considerável tendo em conta não haver procedimentos de controle para a dose da irradiação aplicada ao neonato nas incubadora neonatal das maternidades. Os riscos de hiperbilirrubinemia severa do neonato incluem a possibilidade de surdez, de paralisia cerebral ou mesmo de lesão cerebral em casos extremos. A observada Icterícia pode estar ligada à imaturidade do fígado do bebê. A bilirubinemia é muito freqüente em neonatos e precisa ser tratada para a redução dos citados riscos. O tratamento mais comum é a fototerapia com radiação na faixa do UV-próximo/azul. A fototerapia é realizada por várias sessões de muitas horas que dependem do nível de hiperbilirrubinemia no sangue, TBS (Total Bilirrubine Serum) do bebê. A hiperbilirrubinemia é crítica quando seu nível for igual ou maior que 428 micromol/litro ou 25 mg/dL (Referencia - Previsão e prevenção de hiperbilirrubinemia de neonatal extremo, T.B., Newman et al., Arco Pediatr Adolesc Med/Vol 154, Nov. 2000 pp 1140-1147). Além de permitir reduzir o empirismo do tratamento com o uso de um dosímetro para a faixa de radiação em tela, este pode ser usado para avaliar a condição da fonte de radiação específica de luz usada neste tipo de tratamento. O dosímetro proposto, como instrumento adicional para os neonatologistas poderá monitorar as doses de radiação aplicada durante a fototerapia e evitar excessos, reduzindo o tempo no protocolo de tratamento neonatal. / At the end of the 1980s, researchers from Eastman Kodak announced the electroluminescent properties of non-polymeric organic materials. At the beginning of the 1990s, researchers from the UK showed similar properties of organic polymers, using them as active elements in light emitting devices. It was the beginning of a new research area interfacing the electronics and the new polymeric semiconductors. As a result of the findings on the semiconducting properties of polymers and copolymers, blends and organic-inorganic heterostructures, a new class of materials became the research subject of several groups. Polymer semiconductors exhibit several advantages like simple processing and low production cost. They can be utilized as thin-films with good mechanical properties for use in flexible substrates. Several high-tech enterprises like Philips, Sony, Pioneer, DuPont, Kodak and Uniax are investing strongly in the research and development of such materials and devices, including memories, image sensors, light-emmiting devices, among others. Radiation in a very broad range of wavelengths can affect characteristics of some semiconductor polymers. Their inherent semiconducting feature can be degraded by the photo-oxidation effect, activated by radiation exposition. This suggests the possibility of the development of semiconductor polymer based radiation sensing devices. This work deals with a study of radiation dosimeters for the wavelength range of 400 nm to 500 nm, specifically important at the maternity hospitals in the therapy of newborn babies. To cope with this objective, the study of adequate substrates, development of suitable deposition process for the thin-film devices and study of its properties changes with radiation in the ultraviolet-visible (UV-Vis) range was done. From the different thin-film deposition techniques, the inkjet deposition technique was selected for this study thanks to its production simplicity, potential low cost an, mainly, because it permits the deposition of minute amounts of material, leading to very little material losses. As the active material a polymeric semiconductor of the fluorene family was selected thanks to its easy processing. Researchers of this area, more and more, believe that the Inkjet Printing is one of the very promising deposition techniques for mass production of those devices. The aim of this research is to offer a new tool to be used in the monitor of the irradiation in the phototherapy for severe hyperbilirubinemia of newborn babies. In most cases newborn babies are treated with a considerably empiric protocol considering the inexistence of procedures to control the radiation doses in the treatments. The risks of extreme neonatal hyperbilirubinemia include possibility of deafness, cerebral palsy or brain damage in extreme cases. Jaundice may be due to the immaturity of baby\'s liver. Bilirubinemia is most frequent in newborn and must be treated to reduce such risks. The most common treatment is phototherapy with nearUV-blue radiation. Phototherapy is accomplished by several sessions of many hours depending on the Total Bilirubin Serum (TBS) found in the baby blood. Hyperbilirubinemia is very dangerous to the near-term newborn when its level is equal or greater than 428 micromol/liter or 25 mg/dL (Reference Prediction and prevention of extreme neonatal hyperbilirubinemia, T.B., Newman et al., Arch Pediatr Adolesc Med/Vol 154, Nov. 2000 pp 1140-1147). Besides reducing the empiric treatments based on the nearUV-blue radiation, the use of a sensor can be important to evaluate the condition of the specific type of lamp used in the treatments. The proposed dosimeter can be an additional instrument for the neonatologists to be used in the determination of the phototherapy radiation dose, thus reducing, in the medical protocol, the jaundice treatment time.
24

Medida do Perfil de Dose no Alumínio Irradiado com Raios Gama de Captura de Nêutrons Térmicos Utilizando o Dosímetro Termoluminescente CaSO4:Dy / Measurement of dose profile in aluminum, irradiated wtth thermal neutron capture gamma rays, by using the termoluminescent dosimeter CaSO4:Dy

Federico, Claudio Antonio 10 May 2002 (has links)
Radiação gama com energias maiores que 1,25 MeV são usualmente encontradas em ambientes de reatores, aceleradores de partículas e campos de radiação de origem cósmica. Nestas energias, a resposta de um dosímetro varia fortemente com a espessura de material absorvedor, até atingir um valor máximo conhecido como espessura de equibl^rio de partículas carregadas. O objetivo principal do presente trabalho foi a determinação experimental do perfil de dose absorvida por uma amostra de alumínio, para várias energias de feixes de raios gama, de forma a obter uma relação entre a energia média do campo de radiação gama e a espessura de equilíbrio de partículas carregadas para o alumínio. Os dosímetros foram irradiados com radiação gama produzida pela captura de neutrons térmicos em 23 materiais alvos no arranjo experimental montado no canal tangencial do reator do IPEN-CNEN/SP. Na determinação da camada de equilíbrio de partículas carregadas, foi ajustada aos dados experimentais uma função semi-empirica que permitiu obter a espessura de ETPC (Equilíbrio Transitório de Partículas Carregadas) para cada espectro de radiação gama utilizado neste trabalho, com energia média variando no intervalo de 3,26 a 7,85 MeV. Os resultados experimentais do presente trabalho permitiram obter uma relação entre a energia média do campo de radiação gama e a espessura de ETPC, que apresenta uma excelente concordância com o alcance corrigido dos elétrons gerados naquela energia. / Gamma radiation with energies greater than 1.25 MeV are usually produced in reactor environments, particle accelerators and in cosmic radiation fields. For these energies, the response of a dosimeter heavily vary with the absorber material thickness, up to attain a maximum value named as charged particle equilibrium thickness. The main gol of this paper was the experimental determination of the absorbed dose profile in an aluminum sample for several energies of gamma ray beam, in order to obtain a relationship between the average energy of the gamma radiation field and the charged particle equilibrium thickness. The dosimeters were irradiated with gamma radiation produced by thermal neutron capture in 23 target materials in the experimental arrangement mounted at the tangential beam hole of the BPEN-CNEN/SP reactor. For the determination of the charged particle equilibrium thickness, it was fitted to the experimental data a semi-empirical fimction which allowed to obtain the thickness of CTPE ( Charged Particle Transient Equilibrium ) for each gamma radiation spectrum used in this work, with average energy varying in the interval from 3.26 to 7.85 MeV. The experimental results of the present paper allowed to obtain a relationship between average energy of the radiation field and the CTPE thickness, which presents an excellent agreement with the corrected range for electrons produced in that energy.
25

Medida do Perfil de Dose no Alumínio Irradiado com Raios Gama de Captura de Nêutrons Térmicos Utilizando o Dosímetro Termoluminescente CaSO4:Dy / Measurement of dose profile in aluminum, irradiated wtth thermal neutron capture gamma rays, by using the termoluminescent dosimeter CaSO4:Dy

Claudio Antonio Federico 10 May 2002 (has links)
Radiação gama com energias maiores que 1,25 MeV são usualmente encontradas em ambientes de reatores, aceleradores de partículas e campos de radiação de origem cósmica. Nestas energias, a resposta de um dosímetro varia fortemente com a espessura de material absorvedor, até atingir um valor máximo conhecido como espessura de equibl^rio de partículas carregadas. O objetivo principal do presente trabalho foi a determinação experimental do perfil de dose absorvida por uma amostra de alumínio, para várias energias de feixes de raios gama, de forma a obter uma relação entre a energia média do campo de radiação gama e a espessura de equilíbrio de partículas carregadas para o alumínio. Os dosímetros foram irradiados com radiação gama produzida pela captura de neutrons térmicos em 23 materiais alvos no arranjo experimental montado no canal tangencial do reator do IPEN-CNEN/SP. Na determinação da camada de equilíbrio de partículas carregadas, foi ajustada aos dados experimentais uma função semi-empirica que permitiu obter a espessura de ETPC (Equilíbrio Transitório de Partículas Carregadas) para cada espectro de radiação gama utilizado neste trabalho, com energia média variando no intervalo de 3,26 a 7,85 MeV. Os resultados experimentais do presente trabalho permitiram obter uma relação entre a energia média do campo de radiação gama e a espessura de ETPC, que apresenta uma excelente concordância com o alcance corrigido dos elétrons gerados naquela energia. / Gamma radiation with energies greater than 1.25 MeV are usually produced in reactor environments, particle accelerators and in cosmic radiation fields. For these energies, the response of a dosimeter heavily vary with the absorber material thickness, up to attain a maximum value named as charged particle equilibrium thickness. The main gol of this paper was the experimental determination of the absorbed dose profile in an aluminum sample for several energies of gamma ray beam, in order to obtain a relationship between the average energy of the gamma radiation field and the charged particle equilibrium thickness. The dosimeters were irradiated with gamma radiation produced by thermal neutron capture in 23 target materials in the experimental arrangement mounted at the tangential beam hole of the BPEN-CNEN/SP reactor. For the determination of the charged particle equilibrium thickness, it was fitted to the experimental data a semi-empirical fimction which allowed to obtain the thickness of CTPE ( Charged Particle Transient Equilibrium ) for each gamma radiation spectrum used in this work, with average energy varying in the interval from 3.26 to 7.85 MeV. The experimental results of the present paper allowed to obtain a relationship between average energy of the radiation field and the CTPE thickness, which presents an excellent agreement with the corrected range for electrons produced in that energy.
26

Caracterização das exposições ocupacionais e eficiência da dosimetria pessoal em radiologia intervencionista vascular

Bacchim Neto, Fernando Antonio. January 2017 (has links)
Orientador: Diana Rodrigues Pina / Resumo: A Radiologia Intervencionista (RI) é a área da medicina que proporciona as maiores exposições ocupacionais. Os valores de dose aos quais os intervencionistas são expostos são difíceis de padronizar. Nesta pesquisa apresentamos uma avaliação completa das exposições ocupacionais e determinamos a eficiência de distintos métodos de dosimetria pessoal utilizados na RI. Essa pesquisa foi abordada em 2 etapas, conforme descrito a seguir: A primeira etapa se baseou em caracterizar as exposições ocupacionais em diferentes modalidades de procedimentos de RI vascular para duas categorias de profissionais e estimar o número de procedimentos anuais que cada profissional pode realizar sem exceder os limites de dose. Foi avaliada a exposição ocupacional, através de dosimetria termoluminescente, em diferentes partes do corpo (cristalino, tireoide, tórax, abdômen, pés e mãos) de duas categorias de intervencionistas (principais e assistentes) em três modalidades diferentes de procedimentos de RI vascular. As maiores doses equivalentes foram encontradas para as mão de ambos os profissionais, podendo chegar a aproximadamente 9 mSv em um único procedimento. Algumas regiões dos profissionais em alguns procedimentos podem receber, durante o ano, níveis de doses perigosamente perto dos limites anuais. Dosímetros posicionados no tórax podem subestimar as doses para outras regiões do corpo, especialmente abdômen, extremidades e cristalinos. Na segunda etapa foram avaliadas as eficiências de 6 diferent... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Interventional Radiology (IR) is the area of medicine that provides the largest occupational exposures. The dose values to which interventionists are exposed are difficult to standardize. In this research we present a complete evaluation of occupational exposures and determine the efficiency of different personal dosimetry methods used in IR. This research was performed in 2 stages, as described below: The first step was to characterize the occupational exposures in different modalities of vascular IR procedures for two categories of professionals. We also estimated the number of annual procedures that each professional can perform without exceeding the dose limits. Occupational exposures were evaluated in different body parts (crystalline, thyroid, thorax, abdomen, feet and hands) by two interventional categories (primary and assistants) in three different modalities of vascular IR procedures. The highest equivalent doses were found for the hands of both professionals, reaching approximately 9 mSv in a single procedure. Some regions of professionals in some procedures may receive dose levels during the year dangerously close to annual limits. Dosimeters positioned in the chest may underestimate the doses to other regions of the body, especially the abdomen, extremities and crystalline. The second stage, we evaluated the efficiencies of 6 different personal dosimetry methodologies used internationally to estimate the effective dose received by interventional professionals. An... (Complete abstract click electronic access below) / Mestre
27

Comparações entre doses pediátricas periféricas provenientes de radioterapia conformal e de intensidade modulada

Santos, Marinei do Rocio Pacheco dos 20 August 2010 (has links)
Esta pesquisa apresenta e compara medidas de doses pediátricas periféricas em radioterapia, em regiões de tireóide, coração, mama, abdome, medial de ovários e testículos. Tais doses foram obtidas com TLDs de LiF:Mg,Ti (TLD-100) em pó, posicionados em três objetos simuladores humanóides com tamanhos de crianças de dois, cinco e dez anos, feitos de polietileno de alta densidade e completamente preenchidos com água. Foi empregado um acelerador linear Varian Clinac 600CD para irradiar a cabeça dos três objetos simuladores, com feixes de Raios X produzidos com potencial de 6 MV, com três diferentes planejamentos craniais: (a) IMRT sliding window com o colimador multifolhas rotacionado em 0º, (b) IMRT sliding window com o colimador multifolhas rotacionado em 90º e (c) planejamento conformal (3D). As doses aplicadas foram de 300 cGy e 600 cGy com cinco campos coplanares para todos os planejamentos. Como resultado deste trabalho observa-se que as doses obtidas para todas as irradiações são muito baixas, quando comparadas aos valores de doses determinísticas para as regiões de maior interesse em proteção radiológica e que IMRT 90º proporciona maior blindagem para a radiação de fuga que se direcionaria para o corpo do paciente, oferecendo vantagens quando comparado com os planejamentos conformal e IMRT 0º. / This research presents and compares peripheral pediatric doses measurements in radiation therapy, for of thyroid, heart, breast, abdomen, ovaries and testicles regions, obtained with TLD LiF: Mg, Ti (TLD-100) powder, placed on three humanoid phantoms with sizes of children as two, five and ten years old, made of high density polyethylene and completely filled with water. It at linear accelerator Varian Clinac 600CD was employed to irradiate the heads of the three phantoms, with X-rays beams generated by a potential of 6 MV, with three different skull plannings: (a) IMRT sliding window with multileaf collimator rotated 0°, (b) IMRT sliding window with the multileaf collimator rotated 90° and (c) conformal planning (3D). The doses applied were 300 cGy and 600 cGy with five coplanar fields for all cares planning. The results show that the doses obtained for the all irradiations are very low compared to deterministic dose values deterministic for the regions of greater interest in radiological protection and that IMRT 90º provides more shielding for leakage radiation which would be directed to patient's body, offering advantages when compared to conformal planning and IMRT 0º.
28

Avaliação de Kerma na superfície de entrada da pele em pacientes pediátricos do Hospital de Clínicas de Curitiba

Porto, Lorena Elaine 09 April 2010 (has links)
CAPES / No presente trabalho foram feitas medidas de dose recebida pelos pacientes pediátricos em exames de radiográficos de tórax em uma amostra de 386 exposições nas projeções AP/PA e Perfil. Os pacientes foram divididos em nas faixas etárias de 0-1 ano, 1-5 anos, 5-10 anos e 10-15 anos. Os exames foram realizados no Hospital de Clínicas da UFPR. Foi medida inicialmente a dose de entrada na pele com dosímetros termoluminescentes TLD-100 em uma amostra de 68 exposições, distribuídos pelas faixas etárias adotadas. A dose foi também determinada utilizando-se cálculos dosimétricos, que faz a determinação de dose para cada paciente a partir do rendimento do aparelho de raios X. O programa utiliza como dados de entrada a massa do paciente, a idade, a distância foco-pele, os dados da técnica radiográfica empregada (kV e mAs) e o valor de uma medida do rendimento feita com câmara de ionização para fins de calibração. Os primeiros dados avaliados mostraram doses maiores para os pacientes mais jovens. Uma mudança na técnica radiográfica dos exames contribuiu para a redução das doses. Foi avaliado todo o procedimento radiográfico e ficou caracterizada a necessidade de uma adequação da técnica radiográfica e uma constante otimização de todo o procedimento. Os dados foram colhidos novamente em 2007 e depois em 2009. Num primeiro momento os níveis de dose se mantiveram. Em 2009 os valores voltaram a subir devido ao aumento da carga (mAs). Os dados obtidos foram então comparados com os limites de dose permissíveis determinados pelos órgãos competentes. / In the present work absorbed doses by pediatric patients in chest radiographs were measured in 386 x-ray examinations in AP/PA and LAT projections. The patients were divided in age groups of 0-1 years, 1-5 years, 5-10 years and 10-15 years. The examinations were made at the pediatric room of Clinical Hospital of the Federal University of Paraná. Initially the entrance skin dose was measured with thermoluminescent dosimeters TLD-100 in 68 expositions, distributed in the age groups. The dose was also determined with the software dosimetric calculations that calculates the dose for each patient, from the X-ray equipment yield. The program uses the following data as input: patient mass, age, skin-focus, radiographic technique (kV, mAs), and the yield measurement made with an ionization chamber for calibration. The first evaluated data showed higher doses for the younger patients. A change in the radiographic technique of the examinations contributed to the reduction of the doses. The whole radiographic procedure was evaluated and, thus, showed that the radiographic technique had to be adjusted and the procedure as a whole had to be constantly optimized. Dates were measurement in 2007 again and after 2009. At a first moment the dose levels if had kept. In 2009 the values had come back to go up due to the increase of the load (mAs). The doses were then compared with the regulatory dose limits.
29

Comparações entre doses pediátricas periféricas provenientes de radioterapia conformal e de intensidade modulada

Santos, Marinei do Rocio Pacheco dos 20 August 2010 (has links)
Esta pesquisa apresenta e compara medidas de doses pediátricas periféricas em radioterapia, em regiões de tireóide, coração, mama, abdome, medial de ovários e testículos. Tais doses foram obtidas com TLDs de LiF:Mg,Ti (TLD-100) em pó, posicionados em três objetos simuladores humanóides com tamanhos de crianças de dois, cinco e dez anos, feitos de polietileno de alta densidade e completamente preenchidos com água. Foi empregado um acelerador linear Varian Clinac 600CD para irradiar a cabeça dos três objetos simuladores, com feixes de Raios X produzidos com potencial de 6 MV, com três diferentes planejamentos craniais: (a) IMRT sliding window com o colimador multifolhas rotacionado em 0º, (b) IMRT sliding window com o colimador multifolhas rotacionado em 90º e (c) planejamento conformal (3D). As doses aplicadas foram de 300 cGy e 600 cGy com cinco campos coplanares para todos os planejamentos. Como resultado deste trabalho observa-se que as doses obtidas para todas as irradiações são muito baixas, quando comparadas aos valores de doses determinísticas para as regiões de maior interesse em proteção radiológica e que IMRT 90º proporciona maior blindagem para a radiação de fuga que se direcionaria para o corpo do paciente, oferecendo vantagens quando comparado com os planejamentos conformal e IMRT 0º. / This research presents and compares peripheral pediatric doses measurements in radiation therapy, for of thyroid, heart, breast, abdomen, ovaries and testicles regions, obtained with TLD LiF: Mg, Ti (TLD-100) powder, placed on three humanoid phantoms with sizes of children as two, five and ten years old, made of high density polyethylene and completely filled with water. It at linear accelerator Varian Clinac 600CD was employed to irradiate the heads of the three phantoms, with X-rays beams generated by a potential of 6 MV, with three different skull plannings: (a) IMRT sliding window with multileaf collimator rotated 0°, (b) IMRT sliding window with the multileaf collimator rotated 90° and (c) conformal planning (3D). The doses applied were 300 cGy and 600 cGy with five coplanar fields for all cares planning. The results show that the doses obtained for the all irradiations are very low compared to deterministic dose values deterministic for the regions of greater interest in radiological protection and that IMRT 90º provides more shielding for leakage radiation which would be directed to patient's body, offering advantages when compared to conformal planning and IMRT 0º.
30

Avaliação de Kerma na superfície de entrada da pele em pacientes pediátricos do Hospital de Clínicas de Curitiba

Porto, Lorena Elaine 09 April 2010 (has links)
CAPES / No presente trabalho foram feitas medidas de dose recebida pelos pacientes pediátricos em exames de radiográficos de tórax em uma amostra de 386 exposições nas projeções AP/PA e Perfil. Os pacientes foram divididos em nas faixas etárias de 0-1 ano, 1-5 anos, 5-10 anos e 10-15 anos. Os exames foram realizados no Hospital de Clínicas da UFPR. Foi medida inicialmente a dose de entrada na pele com dosímetros termoluminescentes TLD-100 em uma amostra de 68 exposições, distribuídos pelas faixas etárias adotadas. A dose foi também determinada utilizando-se cálculos dosimétricos, que faz a determinação de dose para cada paciente a partir do rendimento do aparelho de raios X. O programa utiliza como dados de entrada a massa do paciente, a idade, a distância foco-pele, os dados da técnica radiográfica empregada (kV e mAs) e o valor de uma medida do rendimento feita com câmara de ionização para fins de calibração. Os primeiros dados avaliados mostraram doses maiores para os pacientes mais jovens. Uma mudança na técnica radiográfica dos exames contribuiu para a redução das doses. Foi avaliado todo o procedimento radiográfico e ficou caracterizada a necessidade de uma adequação da técnica radiográfica e uma constante otimização de todo o procedimento. Os dados foram colhidos novamente em 2007 e depois em 2009. Num primeiro momento os níveis de dose se mantiveram. Em 2009 os valores voltaram a subir devido ao aumento da carga (mAs). Os dados obtidos foram então comparados com os limites de dose permissíveis determinados pelos órgãos competentes. / In the present work absorbed doses by pediatric patients in chest radiographs were measured in 386 x-ray examinations in AP/PA and LAT projections. The patients were divided in age groups of 0-1 years, 1-5 years, 5-10 years and 10-15 years. The examinations were made at the pediatric room of Clinical Hospital of the Federal University of Paraná. Initially the entrance skin dose was measured with thermoluminescent dosimeters TLD-100 in 68 expositions, distributed in the age groups. The dose was also determined with the software dosimetric calculations that calculates the dose for each patient, from the X-ray equipment yield. The program uses the following data as input: patient mass, age, skin-focus, radiographic technique (kV, mAs), and the yield measurement made with an ionization chamber for calibration. The first evaluated data showed higher doses for the younger patients. A change in the radiographic technique of the examinations contributed to the reduction of the doses. The whole radiographic procedure was evaluated and, thus, showed that the radiographic technique had to be adjusted and the procedure as a whole had to be constantly optimized. Dates were measurement in 2007 again and after 2009. At a first moment the dose levels if had kept. In 2009 the values had come back to go up due to the increase of the load (mAs). The doses were then compared with the regulatory dose limits.

Page generated in 0.0619 seconds