Determinação experimental da distribuição de dose absorvida em diferentes qualidades de feixes mamográficos / Experimental determination of absorbed dose distribution in different qualities of mammographic x-ray beams.

Santos, Josilene Cerqueira 20 December 2017 (has links)
A dose glandular média é a grandeza utilizada para dosimetria em mamografia. Esta grandeza apresenta grande dependência com propriedades específicas referentes ao tipo de mama a ser avaliada, tais como sua glandularidade e espessura comprimida. Depende também das propriedades do espectro de raios X, tais como a combinação anodo/filtro e a tensão aplicada ao tubo, que modificam a camada semirredutora do feixe. A caracterização do feixe de raios X através da medição direta do seu espectro é um procedimento de alta complexidade e de difícil execução em sistemas de mamografia, devido à arquitetura dos equipamentos e da alta taxa de fluência de fótons característica dos feixes. Estes espectros representam a fonte de informações quantitativas e qualitativas mais completa do feixe. O objetivo geral desse trabalho é estimar distribuições de dose glandular em diferentes profundidades de materiais simuladores de tecido mamário por meio de espectros de raios X medidos em mamógrafos. Para isso, foram utilizadas técnicas radiográficas comumente empregadas na mamografia para o rastreamento do câncer de mama. Foi avaliado o comportamento da dose glandular média normalizada pelo kerma no ar incidente (DgNp) com parâmetros relacionados à mama (glandularidade e espessura) e aos espectros (camada semirredutora, tensão, combinação alvo/filtro). Primeiramente, foi desenvolvida uma metodologia experimental para medição dos espectros de raios X nos mamógrafos. Em seguida, foram propostos os seguintes métodos de cálculo da DgNp utilizando esses espectros: Método I, que calcula a DgNp com espectros incidentes; Método II, que utiliza espectros incidentes e transmitidos para este cálculo e Método III, que usa espectros incidentes e transmitidos para estimar a distribuição de dose em profundidade. Por fim, para efeito de comparação, a distribuição da DgNp também foi estimada utilizando dosímetros termoluminescentes (TLDs). A metodologia desenvolvida para medição de espectros mostrou-se eficaz para posicionamento e alinhamento adequados do detector no feixe e consequentemente a medição dos espectros diretos. Os espectros incidentes experimentais mostraram boa concordância com espectros simulados. Os resultados mostraram uma distribuição bem-comportada desses coeficientes (DgNp), com tendência linear ou exponencial, com relação aos parâmetros analisados. Para um dado espectro, os valores de DgNp apresentaram decrescimento exponencial com a espessura do material simulador ao tecido mamário e dependencia linear com a glandularidade. Além disso, esses coeficientes crescem linearmente com o aumento da camada semirredutora e, consequentemente, com a energia efetiva. A partir das distribuições de DgNp (obtidas pelo Método III) foi possível estimar a dose no volume completo da mama com diferença máxima de 5,2% dos valores obtidos com o Método II. A variação da DgNp com a profundidade obtidas com TLDs mostrou-se bastante coerente com os resultados observados com a utilização do Método III. Conclui-se que é possível avaliar a dose glandular em mamografia utilizando espectros de raios X e que a metodologia proposta tem potencial para ser aplicada como procedimentos alternativos para dosimetria em mamografia. / The mean glandular dose is the quantity used for dosimetry in mammography. This quantity has a strong dependence with some properties of the evaluated breast, such as its glandularity and compressed thickness. It also depends on the X-ray spectrum used for the mammographic image production, such as the target/filter combination and the tube voltage, which are related to the half value layer (HVL) of the beam. The X-ray beam characterization by means of the direct measurement of its spectrum is a complex procedure, and it is difficult to be implemented in clinical systems due to the architecture of the mammography equipment and the high photon fluence rates. These spectra provide a complete qualitative and quantitative information of the X-ray beam. The general objective of this work is to estimate mean glandular dose distributions in different depths of breast tissue-equivalent materials (bTEM) considering the X-ray spectra measured in clinical mammography devices. Radiographic techniques commonly applied for breast cancer screening were used. The behavior of the mean glandular dose normalized to the incident air kerma (DgNp), with parameters related to the breast (glandularity and compressed thickness) and to the mammographic spectra (HVL, tube voltage, target/filter combination), was evaluated. First, an experimental methodology was developed to measure X-ray spectra in clinical mammography devices. Then, the following methods for calculating the DgNp using these spectra were considered: Method I, which calculates the DgNp using the incident spectra; Method II, which uses incident and transmitted spectra by the bTEMs, and Method III, which uses incident and transmitted spectra to estimate the dose distributions in depth of the breast equivalent materials. Finally, thermoluminescent dosimeters (TLDs) were used as a comparative method to evaluate DgNp distributions. The methodology developed for measuring spectra proved to be efficient for the proper positioning and alignment of the detector and, consequently, for the measurement of direct X-ray spectra. The experimental incident spectra showed good agreement with spectra simulated in similar conditions. The results showed well-defined trends (either linear or exponential) of the distributions of these coefficients (DgNp) regarding the analyzed parameters. The DgNp values presented an exponential decay with the bTEM thickness and linear decrease with the glandularity. In addition, these coefficients increase linearly with the increase of the HVL and, consequently, with the increase of the effective energy. From the distributions of DgNp (obtained by Method III) it was possible to estimate the DgNp in the whole breast with a maximum difference of 5.2% from the values obtained using the Method II. The variation of the DgNp with the depth, obtained with TLDs, showed to be consistent with the results observed using the Method III. In conclusion, it is possible to evaluate the glandular dose in mammography examinations using X-ray spectra and the suggested methodology, with some adaptations, can be applied as an alternative procedure for dosimetry in mammography.
2

Determinação experimental da distribuição de dose absorvida em diferentes qualidades de feixes mamográficos / Experimental determination of absorbed dose distribution in different qualities of mammographic x-ray beams.

Josilene Cerqueira Santos 20 December 2017 (has links)
A dose glandular média é a grandeza utilizada para dosimetria em mamografia. Esta grandeza apresenta grande dependência com propriedades específicas referentes ao tipo de mama a ser avaliada, tais como sua glandularidade e espessura comprimida. Depende também das propriedades do espectro de raios X, tais como a combinação anodo/filtro e a tensão aplicada ao tubo, que modificam a camada semirredutora do feixe. A caracterização do feixe de raios X através da medição direta do seu espectro é um procedimento de alta complexidade e de difícil execução em sistemas de mamografia, devido à arquitetura dos equipamentos e da alta taxa de fluência de fótons característica dos feixes. Estes espectros representam a fonte de informações quantitativas e qualitativas mais completa do feixe. O objetivo geral desse trabalho é estimar distribuições de dose glandular em diferentes profundidades de materiais simuladores de tecido mamário por meio de espectros de raios X medidos em mamógrafos. Para isso, foram utilizadas técnicas radiográficas comumente empregadas na mamografia para o rastreamento do câncer de mama. Foi avaliado o comportamento da dose glandular média normalizada pelo kerma no ar incidente (DgNp) com parâmetros relacionados à mama (glandularidade e espessura) e aos espectros (camada semirredutora, tensão, combinação alvo/filtro). Primeiramente, foi desenvolvida uma metodologia experimental para medição dos espectros de raios X nos mamógrafos. Em seguida, foram propostos os seguintes métodos de cálculo da DgNp utilizando esses espectros: Método I, que calcula a DgNp com espectros incidentes; Método II, que utiliza espectros incidentes e transmitidos para este cálculo e Método III, que usa espectros incidentes e transmitidos para estimar a distribuição de dose em profundidade. Por fim, para efeito de comparação, a distribuição da DgNp também foi estimada utilizando dosímetros termoluminescentes (TLDs). A metodologia desenvolvida para medição de espectros mostrou-se eficaz para posicionamento e alinhamento adequados do detector no feixe e consequentemente a medição dos espectros diretos. Os espectros incidentes experimentais mostraram boa concordância com espectros simulados. Os resultados mostraram uma distribuição bem-comportada desses coeficientes (DgNp), com tendência linear ou exponencial, com relação aos parâmetros analisados. Para um dado espectro, os valores de DgNp apresentaram decrescimento exponencial com a espessura do material simulador ao tecido mamário e dependencia linear com a glandularidade. Além disso, esses coeficientes crescem linearmente com o aumento da camada semirredutora e, consequentemente, com a energia efetiva. A partir das distribuições de DgNp (obtidas pelo Método III) foi possível estimar a dose no volume completo da mama com diferença máxima de 5,2% dos valores obtidos com o Método II. A variação da DgNp com a profundidade obtidas com TLDs mostrou-se bastante coerente com os resultados observados com a utilização do Método III. Conclui-se que é possível avaliar a dose glandular em mamografia utilizando espectros de raios X e que a metodologia proposta tem potencial para ser aplicada como procedimentos alternativos para dosimetria em mamografia. / The mean glandular dose is the quantity used for dosimetry in mammography. This quantity has a strong dependence with some properties of the evaluated breast, such as its glandularity and compressed thickness. It also depends on the X-ray spectrum used for the mammographic image production, such as the target/filter combination and the tube voltage, which are related to the half value layer (HVL) of the beam. The X-ray beam characterization by means of the direct measurement of its spectrum is a complex procedure, and it is difficult to be implemented in clinical systems due to the architecture of the mammography equipment and the high photon fluence rates. These spectra provide a complete qualitative and quantitative information of the X-ray beam. The general objective of this work is to estimate mean glandular dose distributions in different depths of breast tissue-equivalent materials (bTEM) considering the X-ray spectra measured in clinical mammography devices. Radiographic techniques commonly applied for breast cancer screening were used. The behavior of the mean glandular dose normalized to the incident air kerma (DgNp), with parameters related to the breast (glandularity and compressed thickness) and to the mammographic spectra (HVL, tube voltage, target/filter combination), was evaluated. First, an experimental methodology was developed to measure X-ray spectra in clinical mammography devices. Then, the following methods for calculating the DgNp using these spectra were considered: Method I, which calculates the DgNp using the incident spectra; Method II, which uses incident and transmitted spectra by the bTEMs, and Method III, which uses incident and transmitted spectra to estimate the dose distributions in depth of the breast equivalent materials. Finally, thermoluminescent dosimeters (TLDs) were used as a comparative method to evaluate DgNp distributions. The methodology developed for measuring spectra proved to be efficient for the proper positioning and alignment of the detector and, consequently, for the measurement of direct X-ray spectra. The experimental incident spectra showed good agreement with spectra simulated in similar conditions. The results showed well-defined trends (either linear or exponential) of the distributions of these coefficients (DgNp) regarding the analyzed parameters. The DgNp values presented an exponential decay with the bTEM thickness and linear decrease with the glandularity. In addition, these coefficients increase linearly with the increase of the HVL and, consequently, with the increase of the effective energy. From the distributions of DgNp (obtained by Method III) it was possible to estimate the DgNp in the whole breast with a maximum difference of 5.2% from the values obtained using the Method II. The variation of the DgNp with the depth, obtained with TLDs, showed to be consistent with the results observed using the Method III. In conclusion, it is possible to evaluate the glandular dose in mammography examinations using X-ray spectra and the suggested methodology, with some adaptations, can be applied as an alternative procedure for dosimetry in mammography.
3

Estudo semianalítico da qualidade de imagem e dose em mamografia / Semianalytical study of image quality and dose in mamography

Tomal, Alessandra 24 February 2011 (has links)
Neste trabalho, foram desenvolvidos modelos semianalíticos para estudar os parâmetros de qualidade da imagem (contraste objeto, SC, e razão contraste-ruído, CNR) e a dose glandular normalizada (DgN ) em mamografia convencional e digital. As características de 161 amostras de tecidos mamários (coeficiente de atenuação linear e densidade) e os espectros de raios X mamográficos foram determinados experimentalmente, visando construir uma base de dados consistente destas grandezas para serem utilizadas nos modelos. Os coeficientes de atenuação linear foram determinados utilizando um feixe de raios X polienergético e um detector de Si(Li), e as densidades foram medidas utilizando o método da pesagem hidrostática. Os espectros de raios X de um equipamento industrial, que simula as qualidades de radiação de mamografia, foram medidos utilizando detectores de Si(Li), CdTe e SDD. A resposta de cada detector foi determinada por simulação Monte Carlo (MC). Os modelos semianalíticos desenvolvidos neste trabalho permitem calcular a deposição de energia na mama e no receptor de imagem, e foram utilizados para estudar o SC, a CNR e a DgN, para diferentes tipos de mama (espessura e glandularidade) e características do espectro incidente (combinação ânodo/filtro, potencial do tubo e camada semirredutora), bem como permitem avaliar a figura de mérito (FOM) em mamografia convencional e digital. Os resultados de coeficiente de atenuação e densidade para os diferentes grupos de tecidos mamários, mostram que os tecidos normais fibroglandulares e neoplásicos possuem características similares, enquanto tecidos normais adiposos apresentam menores valores destas grandezas. Os espectros medidos com cada detector, e devidamente corrigidos por suas respostas, mostram que os três tipos de detectores podem ser usados para determinar espectros mamográficos. Com base nos resultados de SC e CNR, foram estimados limites de detecção de nódulos em mamografia convencional e digital, que se mostraram similares entre si. Os resultados de SC, CNR e DgN obtidos também destacam a importância da escolha do modelo da mama e da base de dados de coeficiente de atenuação e espectros de raios X utilizados, uma vez que estes são responsáveis por uma grande variação nas grandezas estudadas. Além disso, os resultados de FOM mostram que, para mamas finas, a combinação Mo/Mo, tradicionalmente utilizada, apresenta o melhor desempenho, enquanto as combinações W/Rh e W/Ag são as mais indicadas para mamas espessas. Para mamas de espessuras médias, a melhor combinação depende da técnica utilizada (convencional ou digital). Finalmente, verificou-se que os modelos semianalíticos desenvolvidos permitem a obtenção de resultados de forma prática e rápida, com valores similares aos obtidos por simulação MC. Desta forma, estes modelos permitirão estudos futuros a respeito da otimização da mamografia, para outros tipos de mama e condições de irradiação. / In this work, semianalytical models were developed to study the image quality parameters (subject contrast, SC, and contrast-to-noise ratio, CNR) and the normalized average glandular dose (DgN) in conventional and digital mammography. The characteristics of 161 breast tissue samples (linear attenuation coefficient and density), and the mammographic x-ray spectra were determined experimentally, aiming to establish a consistent experimental database of these quantities to be used in the models. The linear attenuation coefficients were determined using a polyenergetic x-ray beam and a Si(Li) detector, and the densities were measured using the buoyancy method. The x-ray spectra from an industrial equipment, which reproduces the mammographic qualities, were measured using Si(Li), CdTe and SDD detectors. The responses of the detectors were determined using Monte Carlo (MC) simulation. The semianalytical models developed in this work allow computing the energy deposited in the breast and in the image receptor, and they were employed to study the SC, CNR and DgN, for different types of breast (thickness and glandularity) and incident x-ray spectra (anode/filter combination, tube potential and half-value layer). These models also allow evaluating the figure of merit (FOM) for conventional and digital mammography. The results of attenuation coefficient and density for the tissues analyzed show similar characteristics for the normal fibroglandular and neoplasic breast tissues, while the adipose tissue presents lower values of these quantities. From the x-ray spectra obtained using each detector, and corrected by their respective responses, it is observed that the three types of detectors can be used to determine mammographic spectra. Detection limits for nodules were estimated from the results of SC and CNR, and they were similar for both cases. The results of SC, CNR and DgN also show the importance of the choice of the breast model, and of the database of attenuation coefficient of breast tissues and x-ray spectra, since they largely influence the studied quantities. Besides, the results for FOM show that, for thin breasts, the Mo/Mo spectrum exhibits the better performance, while the W/Rh and W/Ag spectra are recommended for thicker breasts. For average thickness breasts, the more indicated spectra depend on the employed technique (conventional or digital). Finally, it was verified that the semianalytical models developed in this work provided results in a fast and simple way, with a good agreement with those obtained by using MC simulation. Therefore, these models allow further studies, regarding optimization of mammography, for other breast characteristics and irradiation parameters.
4

Estudo semianalítico da qualidade de imagem e dose em mamografia / Semianalytical study of image quality and dose in mamography

Alessandra Tomal 24 February 2011 (has links)
Neste trabalho, foram desenvolvidos modelos semianalíticos para estudar os parâmetros de qualidade da imagem (contraste objeto, SC, e razão contraste-ruído, CNR) e a dose glandular normalizada (DgN ) em mamografia convencional e digital. As características de 161 amostras de tecidos mamários (coeficiente de atenuação linear e densidade) e os espectros de raios X mamográficos foram determinados experimentalmente, visando construir uma base de dados consistente destas grandezas para serem utilizadas nos modelos. Os coeficientes de atenuação linear foram determinados utilizando um feixe de raios X polienergético e um detector de Si(Li), e as densidades foram medidas utilizando o método da pesagem hidrostática. Os espectros de raios X de um equipamento industrial, que simula as qualidades de radiação de mamografia, foram medidos utilizando detectores de Si(Li), CdTe e SDD. A resposta de cada detector foi determinada por simulação Monte Carlo (MC). Os modelos semianalíticos desenvolvidos neste trabalho permitem calcular a deposição de energia na mama e no receptor de imagem, e foram utilizados para estudar o SC, a CNR e a DgN, para diferentes tipos de mama (espessura e glandularidade) e características do espectro incidente (combinação ânodo/filtro, potencial do tubo e camada semirredutora), bem como permitem avaliar a figura de mérito (FOM) em mamografia convencional e digital. Os resultados de coeficiente de atenuação e densidade para os diferentes grupos de tecidos mamários, mostram que os tecidos normais fibroglandulares e neoplásicos possuem características similares, enquanto tecidos normais adiposos apresentam menores valores destas grandezas. Os espectros medidos com cada detector, e devidamente corrigidos por suas respostas, mostram que os três tipos de detectores podem ser usados para determinar espectros mamográficos. Com base nos resultados de SC e CNR, foram estimados limites de detecção de nódulos em mamografia convencional e digital, que se mostraram similares entre si. Os resultados de SC, CNR e DgN obtidos também destacam a importância da escolha do modelo da mama e da base de dados de coeficiente de atenuação e espectros de raios X utilizados, uma vez que estes são responsáveis por uma grande variação nas grandezas estudadas. Além disso, os resultados de FOM mostram que, para mamas finas, a combinação Mo/Mo, tradicionalmente utilizada, apresenta o melhor desempenho, enquanto as combinações W/Rh e W/Ag são as mais indicadas para mamas espessas. Para mamas de espessuras médias, a melhor combinação depende da técnica utilizada (convencional ou digital). Finalmente, verificou-se que os modelos semianalíticos desenvolvidos permitem a obtenção de resultados de forma prática e rápida, com valores similares aos obtidos por simulação MC. Desta forma, estes modelos permitirão estudos futuros a respeito da otimização da mamografia, para outros tipos de mama e condições de irradiação. / In this work, semianalytical models were developed to study the image quality parameters (subject contrast, SC, and contrast-to-noise ratio, CNR) and the normalized average glandular dose (DgN) in conventional and digital mammography. The characteristics of 161 breast tissue samples (linear attenuation coefficient and density), and the mammographic x-ray spectra were determined experimentally, aiming to establish a consistent experimental database of these quantities to be used in the models. The linear attenuation coefficients were determined using a polyenergetic x-ray beam and a Si(Li) detector, and the densities were measured using the buoyancy method. The x-ray spectra from an industrial equipment, which reproduces the mammographic qualities, were measured using Si(Li), CdTe and SDD detectors. The responses of the detectors were determined using Monte Carlo (MC) simulation. The semianalytical models developed in this work allow computing the energy deposited in the breast and in the image receptor, and they were employed to study the SC, CNR and DgN, for different types of breast (thickness and glandularity) and incident x-ray spectra (anode/filter combination, tube potential and half-value layer). These models also allow evaluating the figure of merit (FOM) for conventional and digital mammography. The results of attenuation coefficient and density for the tissues analyzed show similar characteristics for the normal fibroglandular and neoplasic breast tissues, while the adipose tissue presents lower values of these quantities. From the x-ray spectra obtained using each detector, and corrected by their respective responses, it is observed that the three types of detectors can be used to determine mammographic spectra. Detection limits for nodules were estimated from the results of SC and CNR, and they were similar for both cases. The results of SC, CNR and DgN also show the importance of the choice of the breast model, and of the database of attenuation coefficient of breast tissues and x-ray spectra, since they largely influence the studied quantities. Besides, the results for FOM show that, for thin breasts, the Mo/Mo spectrum exhibits the better performance, while the W/Rh and W/Ag spectra are recommended for thicker breasts. For average thickness breasts, the more indicated spectra depend on the employed technique (conventional or digital). Finally, it was verified that the semianalytical models developed in this work provided results in a fast and simple way, with a good agreement with those obtained by using MC simulation. Therefore, these models allow further studies, regarding optimization of mammography, for other breast characteristics and irradiation parameters.