Spelling suggestions: "subject:"doseresponse relationships"" "subject:"doseresponses relationships""
1 |
Radiation effects on custom MOS devicesHarris, Rhodri January 1999 (has links)
No description available.
|
2 |
Predicting normal tissue radiosensitivityDickson, Jeanette January 2000 (has links)
No description available.
|
3 |
New methods to overcome radioresistanceShort, Susan Christine January 2000 (has links)
No description available.
|
4 |
Occupational Exposure to Wood DustAlwis, Kuruppuge Udeni January 1998 (has links)
ABSTRACT Occupational exposure to wood dust and biohazards associated with wood dust (endotoxins, (1->3)-b-D-glucans, Gram (-)ve bacteria and fungi), their correlation to respiratory function, and symptoms among woodworkers have been investigated in the present study. Wood dust, endotoxins, and allergenic fungi are the main hazards found in woodworking environments. Relatively very few studies have been done on wood dust exposure. The present study was designed to comprehensively investigate the health effects of wood dust exposure, and in particular provide new information regarding: Exposure to (1->3)-b-D-glucans in an occupational environment; Levels of exposure to wood dust and biohazards associated with wood dust in different woodworking environments; Correlations among personal exposures, especially correlations between (1->3)-b-D-glucans and fungi exposures, and endotoxins and Gram (-)ve bacteria exposures; Effects of personal exposure to biohazards on lung function; Effects of personal exposure to biohazards on work-related symptoms; and Determinants of inhalable exposures (provide which factors in the environment influence the personal inhalable exposures). Workers at four different woodworking processes; two logging sites, four sawmills, one major woodchipping operation and five joineries situated in the state of New South Wales in Australia were studied for personal exposure to inhalable dust (n=182) and respirable dust (n=81), fungi (n=120), Gram (-)ve bacteria (n=120), inhalable endotoxin (n=160), respirable endotoxin (n=79), inhalable (1->3)-b-D-glucan (n=105), and respirable (1->3)-b-D-glucan (n=62). The workers (n=168) were also tested for lung function. A questionnaire study (n=195) was carried out to determine the prevalence of work-related symptoms. The geometric mean inhalable exposure at logging sites was 0.56 mg/m3 (n=7), sawmills 1.59 mg/m3 (n=93), the woodchipping mill 1.86 mg/m3 (n=9) and joineries 3.68 mg/m3 (n=66). Overall, sixty two percent of the exposures exceeded the current standards. Among joineries, 95% of the hardwood exposures and 35% of the softwood exposures were above the relevant standards. Compared with green mills, the percentage of samples, which exceeded the hardwood standard was high for dry mills (70% in dry mills, 50% in green mills). The respirable dust exposures were high at the joineries compared with the other worksites. Exposure levels to fungi at logging sites and sawmills were in the range 103-104 cfu/m3, woodchipping 103-105 cfu/m3 and joineries 102-104 cfu/m3. The predominant fungi found at sawmills were Penicillium spp. High exposure levels of Aureobasidium pullulans were also found at two sawmills. At the woodchipping mill the predominant species were Aspergillus fumigatus, Penicillium spp., and Paecilomyces spp. The sawmills, which employed kiln drying processes, had lower exposure levels of fungi compared with the green mills. Those workplaces which had efficient dust control systems showed less exposure to fungi and bacteria. Although mean endotoxin levels were lower than the suggested threshold value of 20 ng/m3, some personal exposures at sawmills and joineries exceeded the threshold limit value. The mean inhalable (1->3)-b-D-glucan level at the woodchipping mill was 2.32 ng/m3, at sawmills 1.37 ng/m3, at logging sites 2.02 ng/m3, and at joineries 0.43 ng/m3. For the respirable size fraction, mean endotoxin and mean (1->3)-b-D-glucan concentrations were much lower, being similar to observed dust concentrations. Significant correlations were found between mean inhalable endotoxin and Gram (-)ve bacteria levels (p<0.0001), and mean airborne inhalable (1->3)-b-D-glucan and fungi levels (p=0.0003). The correlations between mean respirable endotoxin levels vs Gram (-)ve bacteria exposure levels (p=0.005), and respirable (1->3)-b-D-glucan exposure levels vs total fungi levels (p=0.005) were also significant. Significant correlations were found between lung function and personal exposures. Multivariate analyses showed that the effect of all the personal exposures on cross-shift decrements in lung function was more prominent among sawmill and chip mill workers compared with joinery workers. Woodworkers had markedly high prevalence of cough, phlegm, chronic bronchitis, frequent headaches, throat and eye irritations, and nasal symptoms compared with controls. Among the woodworkers, smokers had a high prevalence of chronic bronchitis (20%) compared with non-smokers (10%). Some workers also reported a variety of allergy problems due to exposure to various types of wood dust. Both joinery workers and sawmill and chip mill workers revealed significant correlations between work-related symptoms and personal exposures. Chronic bronchitis was significantly correlated with personal exposure to wood dust, endotoxin, (1->3)-b-D-glucan, fungi, and Gram (-)ve bacteria among joinery workers. Whereas among sawmill workers chronic bronchitis was significantly correlated with personal exposure to endotoxin, (1->3)-b-D-glucan, and fungi. Woodworkers showed significant positive correlations between percentage cross-shift change (decrease) in lung function and respiratory symptoms. Significant inverse correlations were also found among percentage predicted lung function and respiratory symptoms. The elevated inhalable dust exposures observed in this study can be explained by a combination of factors, including: lack of awareness of potential health effects of wood dust exposure among both management and workers, aging equipment, inadequate and ineffective dust extraction systems or usually none especially for hand held tools, poor maintenance of the ventilation system in some, non-segregation of dusty processes, dry sweeping, and the use of compressed air jets. The determinant-of-exposure analysis confirmed the field observations. The significant determinants of personal inhalable dust exposures (n=163) were found to be: local exhaust ventilation, job title, use of hand-held tools, cleaning method used, use of compressed air, and green or dry wood processed. Type of wood processed was not found to be statistically significant. A majority of workers (~90%) did not wear appropriate respirators approved for wood dust, while the workers who did wear them, used them on average less than 50% of the time. Workers should be protected by controlling dust at its source. When exposure to wood dust cannot be avoided, engineering controls should be supplemented with the use of appropriate personal protective equipment.
|
5 |
Occupational Exposure to Wood DustAlwis, Kuruppuge Udeni January 1998 (has links)
ABSTRACT Occupational exposure to wood dust and biohazards associated with wood dust (endotoxins, (1->3)-b-D-glucans, Gram (-)ve bacteria and fungi), their correlation to respiratory function, and symptoms among woodworkers have been investigated in the present study. Wood dust, endotoxins, and allergenic fungi are the main hazards found in woodworking environments. Relatively very few studies have been done on wood dust exposure. The present study was designed to comprehensively investigate the health effects of wood dust exposure, and in particular provide new information regarding: Exposure to (1->3)-b-D-glucans in an occupational environment; Levels of exposure to wood dust and biohazards associated with wood dust in different woodworking environments; Correlations among personal exposures, especially correlations between (1->3)-b-D-glucans and fungi exposures, and endotoxins and Gram (-)ve bacteria exposures; Effects of personal exposure to biohazards on lung function; Effects of personal exposure to biohazards on work-related symptoms; and Determinants of inhalable exposures (provide which factors in the environment influence the personal inhalable exposures). Workers at four different woodworking processes; two logging sites, four sawmills, one major woodchipping operation and five joineries situated in the state of New South Wales in Australia were studied for personal exposure to inhalable dust (n=182) and respirable dust (n=81), fungi (n=120), Gram (-)ve bacteria (n=120), inhalable endotoxin (n=160), respirable endotoxin (n=79), inhalable (1->3)-b-D-glucan (n=105), and respirable (1->3)-b-D-glucan (n=62). The workers (n=168) were also tested for lung function. A questionnaire study (n=195) was carried out to determine the prevalence of work-related symptoms. The geometric mean inhalable exposure at logging sites was 0.56 mg/m3 (n=7), sawmills 1.59 mg/m3 (n=93), the woodchipping mill 1.86 mg/m3 (n=9) and joineries 3.68 mg/m3 (n=66). Overall, sixty two percent of the exposures exceeded the current standards. Among joineries, 95% of the hardwood exposures and 35% of the softwood exposures were above the relevant standards. Compared with green mills, the percentage of samples, which exceeded the hardwood standard was high for dry mills (70% in dry mills, 50% in green mills). The respirable dust exposures were high at the joineries compared with the other worksites. Exposure levels to fungi at logging sites and sawmills were in the range 103-104 cfu/m3, woodchipping 103-105 cfu/m3 and joineries 102-104 cfu/m3. The predominant fungi found at sawmills were Penicillium spp. High exposure levels of Aureobasidium pullulans were also found at two sawmills. At the woodchipping mill the predominant species were Aspergillus fumigatus, Penicillium spp., and Paecilomyces spp. The sawmills, which employed kiln drying processes, had lower exposure levels of fungi compared with the green mills. Those workplaces which had efficient dust control systems showed less exposure to fungi and bacteria. Although mean endotoxin levels were lower than the suggested threshold value of 20 ng/m3, some personal exposures at sawmills and joineries exceeded the threshold limit value. The mean inhalable (1->3)-b-D-glucan level at the woodchipping mill was 2.32 ng/m3, at sawmills 1.37 ng/m3, at logging sites 2.02 ng/m3, and at joineries 0.43 ng/m3. For the respirable size fraction, mean endotoxin and mean (1->3)-b-D-glucan concentrations were much lower, being similar to observed dust concentrations. Significant correlations were found between mean inhalable endotoxin and Gram (-)ve bacteria levels (p<0.0001), and mean airborne inhalable (1->3)-b-D-glucan and fungi levels (p=0.0003). The correlations between mean respirable endotoxin levels vs Gram (-)ve bacteria exposure levels (p=0.005), and respirable (1->3)-b-D-glucan exposure levels vs total fungi levels (p=0.005) were also significant. Significant correlations were found between lung function and personal exposures. Multivariate analyses showed that the effect of all the personal exposures on cross-shift decrements in lung function was more prominent among sawmill and chip mill workers compared with joinery workers. Woodworkers had markedly high prevalence of cough, phlegm, chronic bronchitis, frequent headaches, throat and eye irritations, and nasal symptoms compared with controls. Among the woodworkers, smokers had a high prevalence of chronic bronchitis (20%) compared with non-smokers (10%). Some workers also reported a variety of allergy problems due to exposure to various types of wood dust. Both joinery workers and sawmill and chip mill workers revealed significant correlations between work-related symptoms and personal exposures. Chronic bronchitis was significantly correlated with personal exposure to wood dust, endotoxin, (1->3)-b-D-glucan, fungi, and Gram (-)ve bacteria among joinery workers. Whereas among sawmill workers chronic bronchitis was significantly correlated with personal exposure to endotoxin, (1->3)-b-D-glucan, and fungi. Woodworkers showed significant positive correlations between percentage cross-shift change (decrease) in lung function and respiratory symptoms. Significant inverse correlations were also found among percentage predicted lung function and respiratory symptoms. The elevated inhalable dust exposures observed in this study can be explained by a combination of factors, including: lack of awareness of potential health effects of wood dust exposure among both management and workers, aging equipment, inadequate and ineffective dust extraction systems or usually none especially for hand held tools, poor maintenance of the ventilation system in some, non-segregation of dusty processes, dry sweeping, and the use of compressed air jets. The determinant-of-exposure analysis confirmed the field observations. The significant determinants of personal inhalable dust exposures (n=163) were found to be: local exhaust ventilation, job title, use of hand-held tools, cleaning method used, use of compressed air, and green or dry wood processed. Type of wood processed was not found to be statistically significant. A majority of workers (~90%) did not wear appropriate respirators approved for wood dust, while the workers who did wear them, used them on average less than 50% of the time. Workers should be protected by controlling dust at its source. When exposure to wood dust cannot be avoided, engineering controls should be supplemented with the use of appropriate personal protective equipment.
|
6 |
Analise da radiossensibilidade de linfocitos perifericos de pacientes com cancer de pele e de individuos sadios por meio do metodo do micronucleoLOHMANN, TANIA H.O. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:10Z (GMT). No. of bitstreams: 1
06004.pdf: 4196576 bytes, checksum: 707f1ed9565795d26cc6aa938c5f4995 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
7 |
Dosimetria de processos de irradiacao gama com diodos comerciais de silicio / Gamma radiation processing dosimetry with commercial silicon diodesFERREIRA, DANILO C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:20Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
8 |
Efeito citogenetico do sup(153) Sm-EDTMP em linfocitos perifericos de pacientes com cancer metastaticoSILVA, MARCIA A. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:41Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
9 |
Analise da radiossensibilidade de linfocitos perifericos de pacientes com cancer de pele e de individuos sadios por meio do metodo do micronucleoLOHMANN, TANIA H.O. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:10Z (GMT). No. of bitstreams: 1
06004.pdf: 4196576 bytes, checksum: 707f1ed9565795d26cc6aa938c5f4995 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
10 |
Dosimetria de processos de irradiacao gama com diodos comerciais de silicio / Gamma radiation processing dosimetry with commercial silicon diodesFERREIRA, DANILO C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:20Z (GMT). No. of bitstreams: 0 / Este trabalho contempla o desenvolvimento de dosímetros baseados em diodos de Si para a dosimetria de radiação gama para doses desde 1 Gy até 100 Gy. Este intervalo de dose é freqüentemente utilizada em processos de irradiação de cristais, polímeros conjugados e também em vários estudos biológicos conduzidos no Centro de Tecnologia das Radiações (CTR) do IPEN-CNEN/SP. O dosímetro proposto foi construído a partir do diodo cormecial de Si SFH00206 (Siemens), operando em regime fotovoltaico, cujas características elétricas são adequadas para esta aplicação. As correntes geradas no dispositivo pela radiação gama do 60Co dos irradiadores tipo I e II foram registrada por um eletrômetro digital e armazenadas durante todo o tempo de exposição. Em todas as medidas realizadas verificou-se que os sinais de corrente registrados em função do tempo de exposição eram estáveis. Além disso, a fotocorrente do dispositivo mostrou-se linearmente dependente com a taxa de dose desde 6.1x10-2 Gy/min até 1.9x102 Gy/min. As curvas de calibração dos dosímetros, em termos da carga média registrada em função da dose absorvida, foram obtidas pela integração dos sinais de corrente em função do tempo de exposição. Os resultados evidenciaram uma resposta linear do dosímetro, com um coeficiente de correlação melhor que 0,998 para uma dose total absorvida de até 120 Gy. Finalmente, devido aos pequenos erros experimentais, 5% foi possível medir a dose de trânsito devida ao movimento das fontes radioativas de Cobalto-60 nos irradiadores utilizados neste trabalho. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
Page generated in 0.1397 seconds