• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 482
  • 19
  • 9
  • 1
  • Tagged with
  • 513
  • 381
  • 135
  • 121
  • 94
  • 71
  • 50
  • 50
  • 47
  • 40
  • 39
  • 39
  • 38
  • 37
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

"Simulação semi-empírica da resposta termoluminescente sob diferentes geometrias de filtro" / SEMI-EMPIRICAL SIMULATION OF THERMOLUMINESCENT RESPONSE UNDER DIFFERENT FILTER GEOMETRIES

Gabriel Issa Jabra Shammas 21 December 2006 (has links)
Muitos materiais termoluminescentes têm sido desenvolvidos e utilizados para a monitoração individual externa de fótons, mas nenhum tem todas as características desejadas sozinho. Estas características incluem robustez, alta sensibilidade, independência de resposta quanto à energia do fóton, larga faixa de detecção de energia, boa reprodutibilidade, evanescência pequena e curva de emissão termoluminescente simples, com picos abaixo de 150oC. O dosímetro de sulfato de cálcio dopado com disprósio CaSO4:Dy) tem sido usado por muitos laboratórios, principalmente no Brasil e na Índia. Outro fósforo interessante é o fluoreto de cálcio (CaF2). As vantagens destes fósforos começam a ser mais requisitadas e suas desvantagens mais aparentes, no mercado globalizado mais e mais competitivo. Estes fósforos são utilizados em monitoração de área e ambiental devido à sua maior sensibilidade do que outros fósforos, como o LiF:Mg. A sua maior desvantagem é a forte dependência energética da resposta, que deve ser corrigida para suas aplicações em campo, onde o fóton é desconhecido a priori. Um modo interessante de fazer esta correção numa incidência ortogonal da radiação no fósforo é a interposição de um filtro plano vazado entre o feixe e o fósforo. Com o objetivo de reduzir a dependência energética sob incidência em qualquer ângulo, reduzindo a incerteza de medição da dose em campo também, este trabalho apresenta um estudo de simulação em geometrias de filtro esféricas. Foram simuladas irradiações de fótons com raios gama do cobalto 60, com raios-X de 33, 48 e 118 keV, em vários ângulos de incidência de zero a noventa graus. Estas simulações computacionais semi-empíricas, utilizando diferenças finitas em três dimensões, foram feitas em coordenadas esféricas. Os resultados indicaram as melhores espessuras e larguras para a otimização da correção da dependência energética. / Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproductibility, small fading and simple glow curve with peaks above 150oC. Calcium Sulfate Dysprosium doped (CaSO4:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF2). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon radiation is unknown a priori. An interesting way do make this correction in orthogonal incidence of the radiation on the phosphor is to interject a plane leaked filter between the beam and the phosphor. In order to reduce the energetic dependence on any incidence angle, reducing the field dose measurement uncertainty too, this work presents a simulation study on spherical filter geometries. It was simulated photon irradiations with Gamma rays of 60Co and x-rays of 33; 48 and 118 keV, on many incidence angles from zero to ninety degrees. These semi-empirical computational simulations using finite differences in three dimensions were done in spherical coordinates. The results pointed out the best filter thicknesses and widths, in order to optimize the correction on energetic dependence.
132

Desenvolvimento de um sistema de verificação dosimétrica tridimensional utilizando Solução Fricke gel na aplicação para a verificação da Radioterapia em Arco Modulado Volumétrico (VMAT) nos tratamentos com movimentação do alvo pela respiração / Verification system development a dosimetric tridimensional using Solution Fricke gel in the application for verification of radiation therapy in arc modulated volumetric (VMAT) in treatment with target moving for breathing

Roberto Kenji Sakuraba 30 July 2015 (has links)
A Radioterapia em arco modulado volumétrico (VMAT) é uma das modalidades mais avançadas em teleterapia para o tratamento de câncer. Os diversos avanços tecnológicos, bem como a evolução das técnicas de tratamento tornaram o VMAT como uma das modalidades de estado da arte para o tratamento de alguns cânceres. Parte deste avanço é creditada à melhoria na acurácia e na prescrição de dose absorvida recomendada ao paciente ao longo dos anos. Este avanço permite que atualmente seja possível realizar os cálculos dosimétricos, por meio de sistemas de planejamento computadorizado, considerando as heterogeneidades dos pacientes, tais como: tecidos e órgãos com composições diferentes da água (meio de referência em radioterapia), contorno do paciente individualizado e o movimento dos tumores com a respiração. Tais avanços demandam o controle de qualidade destas ferramentas, com objetivo de assegurar que todo o processo de tratamento seja satisfatório e acurado. A comunidade dispõe poucos sistemas experimentais capazes de avaliar, considerando os níveis de incerteza, se os sistemas de planejamento computadorizados são aptos a considerar a movimentação dos alvos nos tratamentos com VMAT. Neste trabalho serão apresentados os resultados obtidos empregando um objeto simulador Fricke Xylenol Gel, com capacidade de mensurar as diferenças introduzidas pela movimentação, utilizando Imagem por Ressonância Magnética - MRI e comparando qualitativamente e quantitativamente os resultados. São discutidas as principais etapas de desenvolvimento deste objeto simulador, seus resultados experimentais, conclusões. / Volumetric Modulated Arc Therapy (VMAT) is one of the methods most commonly used in teletherapy to treat cancer. The various technological advances and the evolution of treatment techniques made the VMAT as one of the state of the art methods for the treatment of some cancers. Part of this improvement is credited to improvements in accuracy and prescription dose absorbed recommended to the patient over the years. This advance allows currently is possible to perform dosimetric calculations by means of the computerized planning system, considering the heterogeneity of patients, such as tissues and organs with different water compositions medium (reference radiation), and individual patient contour the movement of tumors breathing. Such advances require quality control of these tools, in order to ensure that the entire treatment process is satisfactory and accurate. Up to now, the community lacks an experimental system capable of evaluating, considering the uncertainty levels if the computerized planning systems are able to consider the movement of targets in the treatments with VMAT. In this paper, will be presented the results obtained with the phantom Fricke Xylenol Gel, capable of measuring the differences introduced by movement using the Magnetic Resonance Image - MRI and compared qualitatively and quantitatively. The main stages of the phantom development, their experimental results, conclusions and comparisons with other systems are discussed.
133

Estudo comparativo das respostas de diodos de Si para dosimetria de radiação gama / Comparative study of Si diodes response for gamma radiation dosimetry

Kelly Cristina da Silva Pascoalino 07 April 2010 (has links)
Neste trabalho é apresentado um estudo comparativo da resposta de diodos de Si para dosimetria de radiação gama. Os diodos investigados, crescidos pelas técnicas de fusão zonal (Fz) e Czchocralski magnético (MCz), foram processados no Instituto de Física da Universidade de Helsinki no âmbito das pesquisas e desenvolvimento de dispositivos de Si resistentes a danos de radiação segundo a colaboração RD50 do CERN (European Organization for Nuclear Research). Para estudar a resposta dosimétrica dos diodos, eles foram acoplados diretamente no modo fotovoltaico na entrada de um eletrômetro digital para medir o sinal de fotocorrente devido a incidência de raios gama provenientes de uma fonte de 60Co (Gammacell 220). O parâmetro dosimétrico usado para estudar a resposta destes dispositivos foi a carga, obtida pela integração do sinal de corrente pelo tempo de exposição, em função da dose absorvida. Estudos da influência dos procedimentos de pré-irradiação na sensibilidade e estabilidade destes diodos mostraram que a sensibilidade decresce com a dose total absorvida mas depois de uma pré-irradiação de cerca de 873 kGy, eles se tornaram mais estáveis. Efeitos dos danos de radiação eventualmente produzidos nos diodos foram monitorados mediante medidas dinâmicas de corrente e de capacitância depois de cada etapa de irradiação. Ambas as amostras exibiram boa reprodutibilidade de resposta, 2,21% (Fz) e 2,94% (MCz), obtida com 13 medidas consecutivas de 15 kGy comparadas com a equivalente dose de 195 kGy absorvida em uma única etapa de irradiação. É importante notar que estes resultados são melhores do que aqueles obtidos com dosímetros de rotina de polimetilmetacrilato (PMMA) usados em processamento por radiação. / In this work it is presented the comparative study of Si diodes response for gamma radiation dosimetry. The diodes investigated, grown by float zone (Fz) and magnetic Czchcralski (MCz) techniques, were processed at the Physics Institute of Helsinki University in the framework of the research and development of rad-hard silicon devices. To study the dosimetric response of these diodes they were connected in the photovoltaic mode to the input of a digital electrometer to measure the photocurrent signal due to the incidence of gamma-rays from a 60Co source (Gammacell 220). The dosimetric parameter utilized to study the response of these devices was the charge, obtained trough the integration of the current signals, as a function of the absorbed dose. Studies of the influence of the pre-irradiation procedures on both sensivity and stability of these diodes showed that the sensitivity decreased with the total absorbed dose but after a preirradiation of about 873 kGy they became more stable. Radiation damage effects eventually produced in the devices were monitored trough dynamic current and capacitance measurements after each irradiation step. Both samples also exhibited good response reproducibility, 2,21% (Fz) and 2,94% (MCz), obtained with 13 consecutive measurements of 15 kGy compared with the equivalent 195 kGy absorbed dose in one step of irradiation. It is important to note that these results are better than those obtained with routine polimetylmetacrilate (PMMA) dosimeters used in radiation processing dosimetry .
134

Avaliação da resposta de detectores termoluminescentes na dosimetria de feixes clínicos utilizando diferentes objetos simuladores / Response evaluation of thermoluminescent detectors in clinical beams dosimetry using different phantoms

Luciana Cardoso Matsushima 23 August 2010 (has links)
A radioterapia é uma das três principais modalidades de tratamento utilizadas no tratamento de doenças malignas, como o câncer; as duas outras são a quimioterapia e a radiocirurgia. Em contraste com outras especialidades médicas que necessitam principalmente de conhecimento clínico e da experiência de especialistas, a radioterapia, com o uso da radiação ionizante no tratamento do câncer, necessita de grandes investimentos em tecnologias modernas e do esforço colaborativo de diversos profissionais que contribuem para o sucesso do tratamento. Na área de dosimetria clínica, uma calibração eficiente e precisa do feixe de radiação garante o conhecimento da dose fornecida ao paciente, assegurando, portanto, o sucesso do tratamento radioterápico. Este trabalho tem por objetivo o estudo comparativo da resposta termoluminescente dos dosímetros de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN (6 mm de diâmetro e 0,8 mm de espessura) com a resposta dos dosímetros de fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti com 3,15 x 3,15 x 0,9 mm3) na dosimetria de feixes clínicos de fótons (6 e 15 MV) e elétrons (6 e 9 MeV) utilizando objetos simuladores de água sólida (RMI-457), água e PMMA. Foram obtidas as curvas de dose-resposta para a radiação gama do cobalto-60 (60Co) no ar e em condições de equilíbrio eletrônico (placa de PMMA), e para elétrons e fótons clínicos nas profundidades de dose máxima. Foi avaliada também a sensibilidade dos dosímetros termoluminescentes e determinada a reprodutibilidade da resposta e a eficiência intrínseca para os diferentes tipos de simuladores e energias de radiação estudadas. Os resultados obtidos indicam que a principal vantagem do dosímetro de CaSO4:Dy é a sua maior sensibilidade para as doses de radiação avaliadas para os feixes do 60Co, fótons e elétrons, representando, portanto, uma alternativa viável para a aplicação em dosimetria nos setores de radioterapia. / Radiotherapy is one of the three principal treatment modalities used in the treatment of malignant diseases such as cancer, the other two are chemotherapy and radiosurgery. In contrast to other medical specialties that rely mainly on the clinical knowledge and experience of medical specialists, radiotherapy, with its use of ionizing radiation in treatment of cancer, relies heavily on modern technology and the collaborative efforts of several professionals whose coordinated team approach greatly influences the outcome of the treatment. In the area of clinical dosimetry, an efficient and accurate calibration of the radiation beam ensures knowledge of the radiation dose delivered to the patient, allowing thus the success of radiotherapy. This study aims to compare the thermoluminescent response of calcium sulphate doped with dysprosium (CaSO4:Dy) dosimeters produced by IPEN (6 mm in diameter and 0,8 mm tick) with the response of lithium fluoride (3,15 x 3,15 x 0,9 mm3) doped with magnesium and titanium (LiF:Mg,Ti) in dosimetry of clinical photons (6 and 15 MV) and electrons beams (6 and 9 MeV) using solid water (RMI-457), water and PMMA phantoms. Initially, the dose-response curves were obtained for irradiation in cobalt-60 gamma radiation source in air (PMMA plates) and under electronic equilibrium conditions and for clinical electrons and photons beams at depth of maximum dose. The sensitivities of the thermoluminescent dosimeters were also evaluated and the values of their reproducibilities and intrinsic efficiency were determined for the response to differents types of phantoms and radiation energy. The obtained results indicate that the main advantage of CaSO4:Dy dosimeters is the enhanced sensitivity to radiation doses measured for 60Co, photons and electrons beams, thus representing a viable alternative for application in dosimetry in the radiotherapy area.
135

Desenvolvimento e calibração de um sistema dosimétrico de rotina em processamento por irradiação / Development and calibration of a routine dosimetry system for radiation processing

Danilo Cardenuto Ferreira 30 October 2013 (has links)
O desenvolvimento e calibração de um sistema dosimétrico de rotina baseado no fotodiodo comercial e de baixo custo (SFH 206) é apresentado neste trabalho. A sonda dosimétrica foi projetada para operar sem tensão de polarização no modo de corrente direta. As radiações foram realizadas no irradiador Panorâmico de Cobalto-60 no intervalo de taxas de dose de 8,1 Gy/h a 125 Gy/h. As fotocorrentes geradas no diodo, para cada taxa de dose, foram registradas utilizando um eletrômetro digital e foram armazenadas durante todo o tempo de exposição. A resposta em corrente do diodo foi medida em função do tempo de exposição em intervalos de 1 Gy até 200 Gy para doses acumuladas de até 15 kGy. Neste intervalo, a resposta em dose do diodo, em função da carga gerada pela dose, foi linear com coeficiente de correlação melhor que 0,998. Estes resultados foram comparados com os obtidos com filmes Gafchromic frequentemente utilizados em dosimetria de rotina. Para monitorar possíveis danos de radiação gama produzidos no diodo, as sensibilidades em corrente e em carga foram medidas em função da dose absorvida. Para doses até 15 kGy, não foi observado qualquer dano de radiação o que confirma a boa reprodutibilidade de resposta do diodo, melhor do que 3 %. Finalmente, devido aos pequenos erros experimentais ( 5% ) e boa resolução espacial do diodo, foi possível medir a dose de trânsito devida ao movimento da fonte radioativa de Cobalto-60 bem como a distribuição da taxa de dose no Irradiador Panorâmico. / The development and calibration of a routine dosimetry system based on commercial, low cost photodiode (SFH 206) are presented in this work. The dosimeter probe was designed to operate unbiased in the direct current mode. The radiations were performed with Cobalt-60 Panoramic Irradiator facility in the dose-rate range of 8.1 Gy/h - 125 Gy/h. The photocurrents generated in the device, in each dose-rate, were registered with a digital electrometer and stored during the exposure time. The current response of the diode was measured as a function of the time in steps from 1 Gy up to 200 Gy with accumulated dose up to 15 kGy. In this range, the dose-response of the diode, given by the charge as function of dose, was linear with correlation coefficient better than 0.998. These results were compared with those obtained using Gafchromic film dosimetry often used in routine. To monitor possible gamma radiation effects produced on the diode, the current and charge sensitivities were measured as a function of the absorbed dose. For doses up to 15 kGy, it was not observed any radiation damage what confirms the reproducibility of the diode response better than 3 %. Finally, due to the small experimental errors ( 5% ) and good spatial resolution of the diode it was possible to measure the transit dose due to the movement of the Cobalt-60 radioactive source as well the dose-rate mapping in the Panoramic Irradiator.
136

Avaliação de dosímetros termoluminescentes empregando objetos simuladores equivalentes à água para aplicação na dosimetria de feixes clínicos de elétrons / Evaluation of thermoluminescent dosimeters using water equivalent phantoms for application in clinical electrons beams dosimetry

Amanda Bravim 26 January 2011 (has links)
A dosimetria em Radioterapia prevê a calibração do feixe de radiação e a dosimetria de rotina para controle de qualidade, pois o seu principal objetivo é determinar, com maior precisão, a dose absorvida pelo tumor. Este trabalho tem como objetivo avaliar o comportamento de três dosímetros termoluminescentes na dosimetria de feixes clínicos de elétrons. O desempenho de detectores de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN foi comparado com o de dois dosímetros comercialmente disponíveis pela Harshaw, ambos denominados TLD-100, porém com dimensões distintas. Os dosímetros foram caracterizados com a utilização de objetos simuladores de água, água sólida RMI-457 e PMMA em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV. Também foram realizadas medidas em feixes de fótons de 6 e 15 MV (2 e 5 MeV) apenas para comparação de resultados. As curvas de dose-resposta foram obtidas para a radiação gama do 60Co no ar e em condições de equilíbrio eletrônico e para feixes clínicos de fótons e elétrons nas profundidades de máxima dose. A sensibilidade, a reprodutibilidade, a eficiência intrínseca e a dependência energética dos dosímetros termoluminescentes foram estudadas. O CaSO4:Dy apresentou comportamento semelhante ao dos TLD-100 com uma vantagem em relação à sensibilidade para os feixes e doses de radiação estudados. Sendo assim, o dosímetro produzido pelo IPEN pode ser considerado uma nova alternativa para a dosimetria nos departamentos de Radioterapia. / The dosimetry in Radiotherapy provides the calibration of the radiation beam as well as the quality control of the dose in the clinical routine. Its main objective is to determine with greater accuracy the dose absorbed by the tumor. This study aimed to evaluate the behavior of three thermoluminescent dosimeters for the clinical electron beam dosimetry. The performance of the calcium sulfate detector doped with dysprosium (CaSO4: Dy) produced by IPEN was compared with two dosimeters commercially available by Harshaw. Both are named TLD-100, however they differ in their dimensions. The dosimeters were evaluated using water, solid water (RMI-457) and PMMA phantoms in different exposure fields for 4, 6, 9, 12 and 16 MeV electron beam energies. It was also performed measurements in photon beams of 6 and 15 MV (2 and 5 MeV) only for comparison. The dose-response curves were obtained for the 60Co gamma radiation in air and under conditions of electronic equilibrium, both for clinical beam of photons and electrons in maximum dose depths. The sensitivity, reproducibility, intrinsic efficiency and energy dependence response of dosimeters were studied. The CaSO4: Dy showed the same behavior of TLD-100, demonstrating only an advantage in the sensitivity to the beams and radiation doses studied. Thus, the dosimeter produced by IPEN can be considered a new alternative for dosimetry in Radiotherapy departments.
137

Avaliação  dosimétrica de detectores semicondutores para aplicação na dosimetria e microdosimetria em reatores nucleares e instalações de radiocirugia / Dosimetric evaluation of semiconductor detectors for application in neutron dosimetry and microdosimetry in nuclear reactor and radiosurgical facilities

José Patricio Náhuel Cárdenas 19 April 2010 (has links)
Este trabalho tem como objetivo a avaliação dosimétrica de componentes semicondutores (detectores Barreira de Superfície e fotodiodos PIN) para aplicação em medições de dose equivalente em campos de baixo fluxo de nêutrons (rápidos e térmicos), utilizando uma fonte de AmBe de alto fluxo, a instalação de Neutrongrafia do reator IEA-R1 (fluxos térmicos/epitérmicos) e fluxo de nêutrons rápidos do núcleo do reator IPEN/MB-01 (UCRI Unidade Crítica). Para a detecção de nêutrons (térmicos, epitérmicos e rápidos) foram usados componentes moderadores e conversores (parafina, boro e polietileno). Os fluxos resultantes da moderação e conversão foram utilizados para a irradiação de componentes semicondutores (SSB - Barreira de Superfície e fotodiodos). Foi utilizado também um conversor misto constituído de uma folha de polietileno borado (marca Kodak). O método de simulação por Monte Carlo foi utilizado para avaliar de forma analítica a espessura ótima da parafina. O resultado obtido foi similar ao verificado experimentalmente e serviu para avaliar o fluxo de nêutrons emergentes do moderador (parafina). Da mesma forma, através de simulação, foi avaliado também o fluxo de nêutrons rápidos que atinge o conversor de polietileno que cobre a face sensível dos semicondutores. O nível de radiação gama foi avaliado cobrindo o detector por inteiro com uma folha de cádmio de 1 mm de espessura. O reator IPEN/MB-01 foi usado para avaliar a resposta dos detectores para nêutrons rápidos de alto fluxo. Os resultados, de uma forma geral, mostraram concordância e similaridade com os trabalhos desenvolvidos por outros grupos de pesquisas. Foi também estabelecida uma abordagem para o cálculo de dose equivalente utilizando os espectros obtidos nas experiências. / The main objetive of this research is the dosimetric evaluation of semiconductor componentes (surface barrier detectors and PIN photodiodes) for applications in dose equivalent measurements on low dose fields (fast and thermal fluxes) using an AmBe neutron source, the IEA-R1 reactor neutrongraphy facility (epithermal and thermal fluxes) and the Critical Unit facility IPEN/MB-01 (fast fluxes). As moderator compound to fast neutrons flux from the AmBe source was used paraffin and boron and polyethylene as converter for thermal and fast neutrons measurements. The resulting fluxes were used to the irradiation of semiconductor components (SSB Surface Barrier Detector and PIN photodiodes). A mixed converter made of a borated polyethylene foil (Kodak) was also used. Monte Carlo simulation metodology was employed to evaluate analytically the optimal paraffin thickness. The obtained results were similar to the experimental data and allowed the evaluation of emerging neutron flux from moderator, as well as the fast neutron flux reaching the polyethylene covering the semiconductor sensitive surface. Gamma radiation levels were evaluated covering the whole detector with cadmium foil 1 mm thick, allowing thermal neutrons blockage and gamma radiation measurements. The IPEN/MB-01 facility was employed to evaluate the detector response for high neutron flux. The results were in good agreement with other studies published. Using the obtained spectra an approach to dose equivalent calculation was established.
138

Desenvolvimento de um objeto simulador para investigação de heterogeneidades em braquiterapia de alta taxa de dose / Development of a phantom for investigations with heterogeneties in high-dose-rate brachytherapy

Eduardo Santana de Moura 26 March 2015 (has links)
A braquiterapia de alta taxa de dose é uma das modalidades mais utilizadas em braquiterapia para o tratamento de câncer. Os diversos avanços tecnológicos, bem como a evolução das técnicas de tratamento tornaram a braquiterapia de alta taxa de dose uma das modalidades de estado da arte para o tratamento de alguns cânceres. Parte deste avanço é creditada à melhoria na acurácia e na prescrição de dose absorvida recomendada ao paciente, ao longo dos anos. Este avanço permite que atualmente seja possível realizar os cálculos dosimétricos, por meio de sistemas de planejamento computadorizado, considerando as heterogeneidades dos pacientes, tais como: tecidos e órgãos com composições diferentes da água (meio de referência em radioterapia), contorno do paciente individualizado, introdução de aplicadores, dentre outros. Tais avanços demandam o controle de qualidade destas ferramentas, com objetivo de assegurar que todo o processo de tratamento seja satisfatório e acurado. Até o momento, a comunidade carece de um sistema experimental capaz de avaliar, considerando os níveis de incerteza, se os sistemas de planejamento computadorizados são aptos a considerar a heterogeneidade dos tratamentos. Neste trabalho, apresentamos o desenvolvimento de medidas experimentais em um objeto simulador, com capacidade de mensurar as diferenças introduzidas pela heterogeneidade por meio de três técnicas dosimétricas experimentais: termoluminescência, filmes radiocrômicos e ionométrica. Os resultados experimentais foram comparados com as simulações de Monte Carlo e com um sistema de planejamento computadorizado comercial, apto a realizar correções de heterogeneidade em braquiterapia. Discutimos as principais etapas de desenvolvimento deste objeto simulador, seus resultados experimentais e as comparações com os demais sistemas. As conclusões e as etapas futuras deste projeto também são apresentadas. / High dose rate brachytherapy is one of the most widely used modalities in brachytherapy for cancer treatment The various technological advances and the development of treatment techniques have made high dose rate brachytherapy as one of the state of the art methods for the treatment of some cancers. Part of this progress is credited to the improvement in the accuracy and absorbed dose prescription recommended to patients over the years. This advance currently allows the possibility of performing dosimetric calculations, by means of computerized planning systems, considering the heterogeneity of patients, such as: tissues and organs with different water compositions (reference medium in radiotherapy), individualized patient\'s contour and introduction of applicators, among others. Such advances require quality control of these tools, in order to ensure that the entire treatment process is satisfactory and accurate. Nowadays, the community needs an experimental system capable of evaluating, since the uncertainty levels if the computerized planning systems are able to consider the heterogeneity of treatments. In this project, we present the development of experimental measurements into a phantom, capable of measuring the differences introduced by heterogeneity through three experimental dosimetric techniques: thermoluminescence, radiochromic films and ionometric. The experimental results were compared with the Monte Carlo simulations and a commercial treatment planning system able to perform correction of heterogeneity in brachytherapy. We discuss the main stages of development of this phantom, their experimental results and comparisons with other systems. The conclusions and future steps to complete this project are also presented.
139

Dosimetria por cintilação utilizando imagens adquiridas com câmera digital / Scintillation dosimetry using images acquired with digital camera

Biagioni, Fernanda Guzzi 25 May 2018 (has links)
A utilização de detectores de radiação é de imensa importância na área de dosimetria, pois permite a quantificação da dose absorvida no meio. Uma técnica interessante para esta finalidade é o uso de detectores por cintilação. Estudos recentes com cintiladores plásticos e líquidos demonstraram a viabilidade do uso de detecção de cintilação por uma câmera digital com sensor CCD ou CMOS. Desse modo, este trabalho tem como objetivo desenvolver um dosímetro cintilador de baixo custo para viabilidade de seu uso e, de um sistema de detecção de cintilação através de uma câmera digital, para que assim pudesse ser realizada sua caracterização dosimétrica. O sistema dosimétrico foi construído a partir de um cintilador líquido a base de antraceno. Dosimetricamente verificou-se uma linearidade de resposta para a dose de 0,1 a 25,53 Gy, para a taxa de dose de 6,66 Gy/min e uma pequena diminuição da sensibilidade do dosímetro quando aumentada a taxa de dose de irradiação. Com relação à dependência energética, foi verificado um aumento na sensibilidade do dosímetro de 10,8% ao se variar a energia de 100 a 160 kVp. Quando comparado a um cintilador comercial, apresentou uma intensidade de sinal reduzida e, em uma análise de reprodutibilidade, obteve-se uma variação máxima de 2% em relação a repetição de uma mesma medida. O cintilador líquido apresentou baixa estabilidade pré e pós-irradiação, com uma variação de cor e redução do sinal ao decorrer dos dias. Para medidas bidimensionais o sistema montado mostrou-se promissor, uma vez que em medidas de deposição de dose com a profundidade para várias energias de feixes, verificou-se o aumento da penetração da radiação com o aumento da energia do feixe e as medidas de penumbra de um feixe parcialmente blindado com 2 mmPb apresentaram um valor de 1,79 cm, considerando o tipo de tubo gerador e blindagem utilizada. Por toda a caracterização realizada o sistema dosimétrico mostrou-se aplicável para dosimetria, desde que operado considerando as características apresentadas. / The utilization of radiation detector is important in the dosimetric area, because it allow the quantification of absortion dose in the medium. An interesting tehnique for this finalitypurpose is the use of scintillation detector. Recent studies with plastic scintillators and liquid scintillators have demonstrated the feasibility of using scintillation detection by a digital camera with CCD or CMOS sensors. Thus, this study is the intent to develop a low-cost scintillation dosimeter for the feasibility of its use and detection scintillation system through by a digital camera, with the finality of dosimetric characterization. The dosimetric system was constructed from using liquid scintilator based anthracene. A linearity dose response between 0.1 to 25.53 Gy was found for the dose rate of 6.66 Gy/min and the dosimeter sensibility was decreased when the dose rate increased. When varied the energy from 100 to 160 kVp, was verified an increased of 10.8% in the dosimeter sensibility, due the energy dependence. When compared to a commercial dosimeter, it shows signal intensity decreased and, the study of reproducibility, a maximum variation of 2% was obtained in relation to the repetition of the same measure. The liquid scintillator presented low stability before and after irradiation, with a color variation and signal reduction over the days. For two-dimensional measurements the assembled system proved to be promising, since in dose deposition measurements with the depth for several beam energies, the penetration of the radiation was increased with the increase of the beam energy and the penumbra measurements of a narrow beam with 2mmPb presented a value of 1.79 cm, considering the type of generator tube and narrow used. Throughout the characterization carried out the dosimetric system proved to be applicable for dosimetry, if operated considering the characteristics presented.
140

Avaliação das doses resultantes de procedimentos radiodiagnósticos realizados em medicina veterinária e avaliação das doses secundárias de radiação espalhada no corpo clínico e nos proprietários dos animais / Evaluation of doses from radiodiagnotic procedures performed in veterinary medicine and assessing of the doses of secondary radiation in the medical staff and animal owners

Veneziani, Glauco Rogério 25 March 2013 (has links)
O objetivo primordial em radiologia veterinária é a produção de radiografias com qualidade diagnóstica, em uma primeira tentativa. Esse objetivo deve atender a três propósitos: (1) diminuir a exposição à radiação do paciente e trabalhadores; (2) diminuir o custo do estudo para o cliente e (3) produzir dados diagnósticos para rápida interpretação e tratamento do paciente. Esse trabalho teve por objetivo a determinação das doses em cães submetidos a radiografias de tórax e abdômen utilizando a técnica da dosimetria termoluminescente (TL). As doses de radiação foram avaliadas com a utilização de dosímetros termoluminescentes de sulfato de cálcio dopado com disprósio (CaSO4:Dy) e fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti). Os resultados obtidos indicam que é extremamente importante a avaliação das doses de radiação envolvidas em procedimentos diagnósticos de radiologia veterinária, para a avaliação das doses nos animais e para ser usado como um parâmetro para a monitoração individual dos proprietários de animais, que auxiliam no posicionamento, e para a proteção dos trabalhadores ocupacionalmente expostos nas Clínicas de Radiologia Veterinária. / The primary goal in veterinary radiography is to produce radiographs of diagnostic quality on the first attempt. This goal serves three purposes: (1) to decrease radiation exposure to the patient and veterinary personnel; (2) to decrease the cost of the study for the client; and (3) to produce diagnostic data for rapid interpretation and treatment of the patient. This work aimed to determine the doses in dogs submitted to chest and abdomen Xrays using the technique of thermoluminescence (TL) dosimetry. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) and lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti). The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pets owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics.

Page generated in 0.0592 seconds