171

Caracterização de diodos com e sem estrutura de múltiplos anéis de guarda para dosimetria de elétrons

Ramos do Nascimento, Cristina 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T23:14:49Z (GMT). No. of bitstreams: 2 arquivo8685_1.pdf: 2609467 bytes, checksum: df3a1f7a23ceefd241ca386948713bc5 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / A dosimetria de feixes de elétrons de alta energia utilizados em radioterapia é realizada atualmente com câmaras de ionização de placas paralelas. Entretanto, devido aos crescentes avanços nas técnicas de tratamento utilizadas, detectores com maior resolução espacial do que as câmaras de ionização são necessários. Os detectores semicondutores podem ser a melhor solução. Diodos com estrutura de múltiplos anéis de guarda têm sido desenvolvidos para aplicações em campos de alta radiação. Este tipo de diodo é mais resistente aos danos da radiação, e apresenta alto grau de pureza, excelentes características de resposta e pequenas dimensões. O objetivo deste trabalho foi caracterizar dois tipos de diodos, de baixo custo, para dosimetria de feixes de elétrons utilizados em radioterapia: o diodo CERN MGR, com múltiplos anéis de guarda e o diodo XRA-24, sem múltiplos anéis de guarda. As respostas dos diodos foram avaliadas em feixes de elétrons, com energias entre 5 e 15 MeV, através das medidas de repetibilidade e linearidade de resposta com a dose e da dependência com a energia, taxa de dose média, tamanho do campo de radiação e profundidade ao longo do eixo central do campo de radiação. Os resultados mostraram excelente repetibilidade, com coeficiente de variação inferior a 0,4%. Em relação à sensibilidade, foram observados valores 60.000 vezes maiores do que os observados para as câmaras de ionização Markus Advanced e PPC05, quando normalizada pelo volume sensível dos detectores. A dependência energética do diodo CERN MGR foi inferior a 2% para energias entre 10 e 15 MeV e a 7% para energias entre 5 e 9 MeV. Para o diodo XRA-24, a dependência energética foi inferior a 8,5% para as energias entre 8 e 12 MeV. A variação da resposta do diodo CERN MGR em função da taxa de dose média foi cerca de 0,2%. Os fatores de saída de campo medidos com o diodo CERN MGR concordaram dentro de 2% em relação aos medidos com a câmara de ionização. As curvas de porcentagem de dose profunda obtidas com os dois diodos possibilitaram a determinação do índice de qualidade dos feixes dentro de 1% em relação aos valores obtidos com a câmara de ionização. A partir deste estudo, conclui-se que os dois tipos de diodos, com e sem múltiplos anéis de guarda, são alternativas confiáveis e econômicas para a realização da dosimetria de feixes de elétrons aplicados em radioterapia. Eles podem ser utilizados na dosimetria de técnicas que necessitam de pequenos campos de radiação e para dosimetria in vivo
172

Novas rotas de preparação de filmes de polianilina e caracterização dosimétrica para radiação gama em altas doses

Paula Lima Pacheco, Ana January 2003 (has links)
Made available in DSpace on 2014-06-12T23:14:57Z (GMT). No. of bitstreams: 2 arquivo8993_1.pdf: 2950400 bytes, checksum: 22e85ebad0ed18e65dfe07ff3a73864d (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / Este trabalho apresenta um novo material polimérico condutor, a base de polianilina (PANI) na forma de filmes finos, que foi utilizado na confecção de dispositivos com fins dosimétricos. Para o preparo dos dispositivos os filmes foram depositados sobre as superfícies de substratos de poli(metacrilato de matila) (PMMA). Esta deposição foi feita através do espalhamento de uma pasta altamente viscosa e homogênea, contendo poli(ácido acrílico) e agente oxidante (MnO2), sobre as superfícies dos substratos de PMMA (formando uma película). Em seguida o substrato contendo a película foi imerso em uma solução ácida de anilina resultando na formação dos filmes. Os filmes formados por esta nova metodologia de síntese apresentam resistividade elétrica (6 x 102 W. m.), boa resistência mecânica e maior aderência aos eletrodos do sistema, quando comparados com os primeiros dispositivos desenvolvidos. A caracterização foi feita por infravermelho, medidas de condutividade elétrica e pela análise elementar de manganês. Os resultados dos ensaios dosimétricos mostraram: correlação linear (r2 = 0,9928) para variação da resistência elétrica em função da dose de irradiação gama, na faixa de 1000 6000 Gy; erro médio menor que 5%; sensibilidade de resposta; e estabilidade de suas propriedades por três dias antes e após a irradiação. A utilização do compósito PANI/poli(ácido acrílico) como dosímetro, para aplicações em instalações industriais que trabalhem com altas doses de radiação gama, foi estudada e resultou em uma curva de calibração com excelentes resultados. Os dispositivos dosimétricos preparados de acordo com esta nova rota apresentam leitura em tempo real e são de baixo custo. Sendo assim, podem vir a ser utilizados para calibração de fontes radioativas industriais, substituindo com eficácia o dosimetro Fricke (modificado) que vem sendo utilizado neste intervalo de dose
173

Quantificação de arsênio, zinco, cobalto, cromo e bário no solo de uma área agriculturável do Agreste de Pernambuco

Dias Bezerra, Jairo 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:15:37Z (GMT). No. of bitstreams: 2 arquivo7032_1.pdf: 1439685 bytes, checksum: 93549e0e8d0b438208dcd20ff21cffed (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Elevadas concentrações de metais pesados em um ecossistema dependem da sua formação geológica e/ou da ação antrópica, diversas ações podem contaminar o meio ambiente e os seres vivos, sendo importânte monitorar o ambiente e controlar a presença desses metais na cadeia alimentar, principalmente do As, Zn, Co, Cr e Ba, devido aos níveis de toxicidade, disponibilidade e especiação química. Em regiões isentas de processos antropogênicos, as concentrações de metais pesados são consideradas naturais, originadas da composição das rochas de origem e da evolução pedogeomorfológica. Em uma área com altos níveis de radionuclídeos primordiais, atividades agrícolas e produção de leite em grande escala no agreste de Pernambuco no município de Pedra, foram monitorados os teores de As, Zn, Co, Cr e Ba no solo. Trinta e quatro amostras com 100 mg de cada, solo e rochas, foram ativadas por oito horas com nêutrons juntamente com os padrões GS-N (ANRT) e BE-N (IWG-GIT) e analisadas por espectrometria gama de alta resolução, sendo a primeira aquisição após sete dias e a segunda quinze dias após a irradiação. As concentrações medias apresentaram resultados menores que 0,16 mg.kg-1 a 6,7 mg.kg-1 para o As; 17 mg.kg-1 a 119 mg.kg-1 para o Zn; 2,45 mg.kg-1 a 213 mg.kg-1 para o Co; 11,50 mg.kg-1 a 180 mg.kg-1 para o Cr e 164 mg.kg-1 a 61.313,50 mg.kg-1 para o Ba. Considerando os resultados obtidos e comparando-os com os valores de prevenção e intervenção estabelecido pela resolução 420/2009 do Conselho Nacional do Meio Ambiente (CONAMA) do Brasil, as concentrações do Ba encontram-se acima do valor de prevenção e 91% delas acima do valor de intervenção. As, Zn e Cr apresentaram quase 100% dos resultados abaixo do valor de prevenção e 12% dos valores do Co foram superiores ao valor de prevenção. Considerando que a área de estudo não apresenta atividades industriais, as altas concentrações determinadas para o Ba são provenientes de processos naturais e os níveis encontrados evidenciam uma possível contaminação de fontes de água e alimentos produzidos nesta região
174

Desenvolvimento do FrameDose: uma plataforma computacional para organização de informações técnicas relacionadas com modelos computacionais de exposição

Resende Filho, Tennyson Accetti 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:15:44Z (GMT). No. of bitstreams: 2 arquivo8467_1.pdf: 3087609 bytes, checksum: a05c3722ae5b084578c4d8aa0c5b10ce (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O Trabalho desenvolveu uma plataforma computacional visando disponibilizar grupo GDN/CNPq e à comunidade científica interessada, informações técnicas sobre modelos computacionais de exposição desenvolvidos pelo grupo desde 2004. Trata-se de um software que integra e disponibiliza ferramentas úteis em avaliações dosimétricas já consagradas meio acadêmico, documentos técnicos e modelos computacionais de exposição desenvolvidos pelo grupo. O framework aqui desenvolvido foi construído utilizando um ambiente visual Studio.net, e também dá suporte ao desenvolvimento de aplicações seguindo o padrão projeto Façade, permitindo agregar outros sistemas desenvolvidos, mas também tornou- uma solução multi banco de dados através do padrão Factory Method. O presente trabalho detalhes da construção da plataforma de software e conclui utilizando o FrameDose para executar, passo a passo, um dos MCEs disponíveis no banco de dados. O trabalho desenvolvido cria um ambiente orientado a objetos que permite ao usuário, com um simples clique do mouse, ativar processos diferentes, executar aplicativos em linha de comando, executar aplicativos de suporte, disponibilizar, livremente, textos e imagens já produzidos pelo GDN/CNPq úteis para estudos sobre MCEs. Isto constitui uma ferramenta inestimável para qualquer estudante ou pesquisador em dosimetria numérica das radiações ionizantes
175

Utilização de redes neurais artificiais para identificação de energia em campos fotônicos com materiais termoluminescentes

Ramos da Silveira, Renata January 2006 (has links)
Made available in DSpace on 2014-06-12T23:17:03Z (GMT). No. of bitstreams: 2 arquivo9110_1.pdf: 1563256 bytes, checksum: 28869f7530bc27f7721347b575f57574 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / A alta qualidade de um serviço de monitoração individual é de fundamental importância para a segurança dos trabalhadores que exercem suas atividades em ambientes controlados e dependem de avaliações precisas das doses que receberam e podem vir a receber durante o desempenho das suas atividades profissionais. O investimento em pesquisas que possibilitem o aperfeiçoamento da qualidade da resposta fornecida com o sistema dosimétrico utilizado é de fundamental importância. Para isto, o Laboratório de Dosimetria Temoluminescente do Centro Regional de Ciências Nucleares, Instituto da Comissão Nacional de Energia Nuclear, possui um programa que visa pesquisar, testar e implementar novos processos que resultem na melhoria da qualidade de seus serviços. Objetivando identificar os espectros em energia para campos fotônicos, foi investigada neste trabalho a aplicabilidade da inteligência artificial, através do uso de uma rede neural multicamadas, como ferramenta de classificação de padrões em energia, associada a um sistema dosimétrico termoluminescente (TLD-700 e TLD-600). Os dosímetros foram expostos inicialmente a diversas energias médias conhecidas, entre 16 keV e 1,2 MeV, para o intervalo de doses de 0,5 a 10 mSv, com o propósito de gerar um conjunto de dados de treinamento para a rede neural. Posteriormente, um novo conjunto de dosímetros irradiados em energias desconhecidas para a rede neural, foi utilizado para testes. A metodologia empregada neste trabalho se mostrou adequada à aplicação na classificação de energias. As melhores respostas foram obtidas para irradiações com altas doses, com 100% de acerto, para 10 mSv
176

Dosimetria e qualidade de imagem em mamografia digital

XAVIER, Aline Carvalho da Silva 28 August 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-04-15T15:22:54Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Aline Carvalho da Silva Xavier.pdf: 7741739 bytes, checksum: a144ef1082bc63af0c0c529b5b83b059 (MD5) / Made available in DSpace on 2016-04-15T15:22:54Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Aline Carvalho da Silva Xavier.pdf: 7741739 bytes, checksum: a144ef1082bc63af0c0c529b5b83b059 (MD5) Previous issue date: 2015-08-28 / FACEPE / A mamografia é o método de diagnóstico mais eficaz na detecção precoce de doenças mamárias. Os sistemas digitais permitem obter radiografias com melhor qualidade de imagem, mas nem sempre estão associadas a protocolos de aquisição otimizados, resultando em doses absorvidas mais elevadas nas glândulas mamárias. Neste sentido, tornam-se pertinentes levantamentos dosimétricos e avaliações da proteção radiológica nas instituições que realizam mamografias. O presente trabalho tem como objetivo estimar a dose glandular média (DGM) em pacientes que realizaram mamografias em sistemas digitais de Recife, Brasil e avaliar a qualidade das imagens obtidas. Foram avaliados: um mamógrafo Siemens, modelo Mammomat 3000 Nova e leitora CR Carestream, modelo Kodak DirectView; dois mamógrafos digitais DR Lorad, modelo Hologic Selenia e um equipamento analógico (telafilme) Lorad M-IV com uma processadora de filmes Kodak, modelo X-Omat 2000. As DGMs foram estimadas a partir da metodologia descrita por Dance e colaboradores, em pacientes com idades entre 40 e 64 anos, com espessuras de mama comprimida que variaram entre 2 e 9 cm. Foram levadas em conta apenas as incidências de rotina (CCD, CCE, MLOD, MLOE). Ao todo, foram coletados os seguintes parâmetros de irradiação de 5200 mamografias: tensão (kV); carga (mAs); combinação anodo/filtro, bem como, a espessura da mama comprimida, força de compressão utilizada e idade da paciente. Em relação à qualidade da imagem, foram analisadas a função da transferência de modulação (MTF), a razão sinal-ruído (SNR) e a razão contraste-ruído (CNR) para diferentes espessuras de simuladores de mama, de acordo com o documento Humam Health Series 17, da Agência Internacional de Energia Atômica. Paralelamente, utilizando os mesmos critérios de avaliação, médicos radiologistas analisaram 50 imagens mamográficas. Os resultados mostraram que os valores das DGMs foram de: 2,70±0,50 mGy para o equipamento tela-filme, 3,91±0,72 mGy para o equipamento CR, 2,86±0,53 mGy para o DR1 e 3,83±0,70 mGy para o DR2. As espessuras médias das mamas foram, respectivamente: 4,82 cm; 6,73 cm; 6,02 cm; 6,11 cm. A força de compressão foi menor do que o indicado para os equipamentos digitais e maior para o tela-filme. Os valores de DGM obtidos com o simulador de mama foi menor que os obtidos para paciente com espessura de mama equivalente. O parâmetro SNR foi considerado adequado para todos os equipamentos. A razão contraste-ruído não foi satisfatória para mamas mais espessas, porém a DGM se mostrou bem abaixo do limite recomendado para este tipo de mama, fazendo-se necessário o ajuste no controle automático de exposição. A MTF foi satisfatória tanto para o equipamento CR quanto para o DR1. A avaliação das imagens clínicas identificou falhas no posicionamento, indicando a necessidade de treinamento para os operadores dos equipamentos de mamografia digital. De maneira geral, espera-se, com este estudo, despertar e educar os profissionais envolvidos sobre a importância dos conceitos de proteção radiológica em mamografias digitais. / The mammography is the most effective diagnostic method for breast disease detection. Digital systems improve image quality, but not always follow optimization protocols for image acquisition and it may result in higher doses absorbed by the mammary glands. Therefore, it is important to conduct radiological protection studies in patients. Thus, this study aims to estimate the mean glandular dose (MGD) in patients who underwent mammograms in digital systems in Recife, Brazil, and to analyze the image quality. This study was conducted with: one Siemens mammography unit and a Carestream CR reader, Kodak DirectView; two Lorad Hologic Selenia digital mammography DR, and one Lorad M-IV analogic equipment with a Kodak film processor, X-Omat 2000. In order to evaluate the MGD, tests were conducted in patients with ages between 40 and 64 years old and breast thickness between 2 and 9 cm. Only the routine incidents were taken into account (RCC, LCC, RMLO, LMLO). The irradiation parameters of 5200 mammograms were analyzed among these four equipment. were recorded (kV, mAs, anode/filter), as well as the thickness of the compressed breast and the patient’s age. The MGD was calculated using the methodology described by Dance et al. The image quality was assessed through the modulation transfer function (MTF), the signal to noise ratio (SNR) and contrast to noise ratio (CNR) for different thicknesses of phatom, according to Humam Health Series 17 document of the International Atomic Energy Agency. Furthermore, the quality of 50 mammograms were evaluated by radiologists. The results showed that the value of MGD was 2.70±0.50 mGy to screen-film equipment, 3.91±0.72 mGy for CR equipment, 2.86±0.53 mGy for the DR1 and 3.83±0.70 mGy for the DR2. The average thicknesses were, respectively: 4.82 cm; 6.73 cm; 6.02 cm; 6.11 cm. The compression force was smaller than indicated for the digital equipment and greater for screen-film. The MGD values obtained with the phantom were lower than those obtained for patients with breast equivalent thickness. The SNR was suitable for all equipment. In most thicker breasts, CNR was not satisfactory, but DGM was below the recommended range for this type of breast, allowing to conclude that an adjustment in automatic exposure control is needed to improve the CNR, even though MGD might increase. The MTF was satisfactory for both CR and DR1 equipment. The evaluation of clinical images showed failure in positioning which indicates lack of training of mammography technicians. In general this study expects to awake and educate professionals of this field about the importance of radiation protection concepts in digital mammograms.
177

Dosimetria de pacientes pediátricos em exames de tomografia computadorizada de crânio

ARAÚJO, Max Well Caetano de 27 August 2015 (has links)
Submitted by Haroudo Xavier Filho (haroudo.xavierfo@ufpe.br) on 2016-04-22T18:09:16Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação final Max-FINAL .compressed.pdf: 3341309 bytes, checksum: d495284374075775bce6c91531257a7e (MD5) / Made available in DSpace on 2016-04-22T18:09:16Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação final Max-FINAL .compressed.pdf: 3341309 bytes, checksum: d495284374075775bce6c91531257a7e (MD5) Previous issue date: 2015-08-27 / A tomografia computadorizada (TC) é um dos métodos mais importantes de radiodiagnóstico, porém, pode resultar em altas doses absorvidas pelos pacientes quando comparado com exames radiográficos convencionais. O objetivo deste trabalho é avaliar as doses absorvidas pelos pacientes pediátricos nos procedimentos de tomografia computadorizada de crânio realizados em Recife, Brasil, utilizando o software de simulação computacional CALDose_XCT. Os parâmetros de irradiação para os procedimentos de TC de crânio pediátrico de 108 pacientes foram coletados e divididos nas seguintes faixas etárias: <1; 1 a 5; 5 a 10; e 10 a 15 anos de idade. Os valores de índice volumétrico de kerma ar em TC (CVOL) e produto kerma ar-comprimento para exames completos de TC (PKL,CT) foram estimados para cada exame e comparados com os níveis de referência internacional. Foram estimados os valores das doses absorvidos por órgãos relevantes (cristalino, cérebro, mucosa oral e glândulas salivares) utilizando o CALDose_XCT. Outra simulação foi realizada utilizando um fantoma de cabeça com inclinação de 18º para avaliar a redução da dose absorvida quando se utiliza a inclinação do gantry ou da cabeça do paciente. Os parâmetros de irradiação selecionados na maioria dos exames pediátricos avaliados não estão otimizados, já que foram observados valores maiores ou iguais aos parâmetros recomendados para exames em adultos. A maioria dos valores estimados de CVOL foram menores que os níveis de referência referência internacionais para exames pediátricos de TC. Por outro lado, situação inversa ocorreu com os valores de PKL,CT, devido ao uso de valores elevados de comprimento de varredura, em alguns casos maiores que a cabeça inteira do paciente. A maioria dos exames avaliados resultou em valores estimados de PKL,CT acima dos limites recomendados. A simulação da inclinação da cabeça dos pacientes pediátricos para exames de crânio resultou em redução da dose absorvida pelos olhos, mucosa oral e glândulas salivares, demostrando ser um método eficiente para otimização da proteção radiológica nestes procedimentos. Deste modo, ressalta-se a importância de implementação de um programa de garantia de qualidade no serviço, com o objetivo de otimizar os procedimentos e reduzir o detrimento para os pacientes pediátricos submetidos a exames de tomografia computadorizada. / The computed tomography (CT) is one of the most important methods for radio diagnostics, resulting, however, in high absorbed doses to the patients. The objective of this work is to evaluate the pediatric head CT examinations performed at one hospital in Recife, Brazil, and to estimate the mean absorbed doses to organs using the computational simulation software CALDose_XCT. The irradiation parameters used with 108 pediatric head CT examinations were registered and divided in the following age ranges: <1; 1 to 5; 5 to 10; and 10 to 15 years-old. The volume CT air kerma index (CVOL) and the air kerma-length product for full CT examinations (PKL,CT) were estimated to each examination and compared to international diagnostic reference levels. The mean absorbed doses to relevant organs (eye lens, brain, oral mucosa and salivary glands) were simulated using CALDose_XCT. Another simulation was made using a head phantom tilt of 18º, in order to evaluate the dose reduction to some organs using either the gantry or head tilt. The results showed that the irradiation parameters used in the most of the examinations are not optimized, since it was possible to observe tube potential and current-time product values higher than the recommended values to adult examinations. Most of the CVOL values were lower than the international reference levels for pediatric CT examinations. On the other hand, the contrary was observed with the PKL,CT, due to the use of large scan ranges, in some cases, bigger than the patient’s entire head. The simulation of the patient head tilt resulted in absorbed dose reduction to the eyes, oral mucosa and salivary glands, showing to be an efficient method to optimize the radiological protection of pediatric CT examinations. Thus, it can be highlighted the importance of a quality assurance program in the service, with the objective of optimizing the procedures and reducing the risk to the pediatric patients.
178

Avaliação do quartzo como dosímetro pessoal baseado na luminescência opticamente estimulada / Evaluation of the quartz as personal dosimeter based on optically stimulated luminescence

Mineli, Thays Desirèe, 1985- 27 August 2018 (has links)
Orientadores: Eduardo Tavares Costa, André Oliveira Sawakuchi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-27T00:20:49Z (GMT). No. of bitstreams: 1 Mineli_ThaysDesiree_M.pdf: 1544477 bytes, checksum: 80869854299a120a6e91842425c1e644 (MD5) Previous issue date: 2015 / Resumo: O uso de radiação ionizante é cada vez mais intenso, seja na indústria seja na área médica. Os efeitos nocivos da radiação ionizante exigem medidas de segurança na sua utilização e um dos meios mais comuns para proteção da saúde do operador de equipamentos que usam esta radiação é o controle da dose que este pode receber em determinado período de tempo. Para tal controle, são normalmente utilizados dosímetros pessoais. Estudos sobre datação de sedimentos costeiros e fluviais do Brasil têm encontrado tipos específicos de quartzo com excelentes características dosimétricas. Com o objetivo de analisar as propriedades dosimétricas de amostras de quartzo de elevada sensibilidade de luminescência e avaliar a sua possível utilização na dosimetria pessoal, foram feitos testes comparativos com amostra do principal e mais utilizado dosímetro pessoal do tipo OSL (Optically Stimulated Luminescence), o Al2O3:C. Este trabalho apresenta as características de luminescência de amostras de quartzo. Essas características foram determinadas por testes de recuperação de dose conhecida (dose recovery) por meio de protocolo de alíquota única (Single-Aliquot Regenerative ¿ SAR) em amostras irradiadas por fonte de radiação beta. Foram realizados testes de sensibilidade e de estabilidade do sinal OSL e testes com radiação gama. Os resultados mostraram que as amostras de quartzo estudadas foram capazes de recuperar com exatidão doses de 50 mGy a 50Gy. Estimou-se que as amostras de quartzo saturam em doses (114-175 Gy) superiores à dose de saturação da amostra de Al2O3:C (35 Gy). A dose mínima capaz de ser medida pelas amostras de quartzo variou de 0,2 mGy (para radiação gama) a aproximadamente 20 mGy (para radiação beta). As amostras de quartzo não apresentaram fading do sinal OSL. O sinal OSL ultravioleta da amostra de Al2O3:C cresceu com o tempo. A amostra de Al2O3:C apresentou maior sensibilidade em comparação às amostras de quartzo no teste com radiação beta. A sensibilidade da amostra de quartzo TE65B no teste com radiação gama foi superior à sensibilidade da amostra Al2O3:C. Estes resultados indicam que as amostras de quartzo estudadas têm potencial como material para dosímetros e incentivam estudos mais aprofundados para avaliar o uso destes tipos de quartzo como elementos sensores em dosímetros pessoais / Abstract: The use of ionizing radiation is becoming more intense, whether in industry or in the medical field. The harmful effects of ionizing radiation require safety measures in its use. One of the most common ways to protect the health of the operator of ionizing radiation equipment is the dose control that he/she can receive in a given time period. Personal dosimeters are used for this purpose. Studies on dating of coastal and fluvial sediments in Brazil have found quartz types with very high luminescence signal and excellent dosimetric characteristics. In order to analyze the dosimetric properties of very bright Brazilian quartz samples and evaluate their use in personal dosimetry, comparative tests with the most used personal OSL (Optically Stimulated Luminescence) dosimeter, Al2O3:C, were made. This work presents the luminescence characteristics of quartz samples. These characteristics were determined by dose recovery tests using a Single-Aliquot Regenerative dose protocol (SAR) in samples irradiated by beta radiation. Sensitivity and stability tests and gamma radiation tests were made. The results have shown that the studied quartz samples were able to recover at least a dose range from 50 mGy to 50 Gy. It was estimated that the quartz samples saturate in doses (114-175 Gy) above the saturation dose of Al2O3:C sample (35 Gy). The minimum dose capable of being measured by the quartz samples ranged from 0.2 mGy (for gamma rays) to about 20 mGy (for beta radiation). The quartz samples showed no fading of the OSL signal. The ultraviolet OSL signal of Al2O3:C sample increased with time. The Al2O3:C sample showed higher sensitivity compared to quartz samples in beta radiation test. However, the sensitivity of TE65B quartz sample for the gamma radiation test was higher than the sensitivity of the Al2O3:C sample. These results indicate that the studied quartz samples have potential as dosimeter material and encourage further studies to evaluate the use of this type of quartz as sensor element in personal dosimeters / Mestrado / Engenharia Biomedica / Mestra em Engenharia Elétrica
179

Análise Radiométrica de Feixes de Fótons de Alta Energia - Elaboração do Plano de Radioproteção Aplicado a Radioterapia Veterinária

Ferreira, Gizele Cristina January 2019 (has links)
Orientador: Marco Antônio Rodrigues Fernandes / Resumo: A proposta do trabalho é a elaboração de um Plano de Radioproteção e a apresentação da rotina de procedimentos de dosimetria de feixes de teleterapia para a adequação em serviços de radioterapia dedicados à medicina veterinária. São apresentados os principais parâmetros radiométricos dos feixes de radiação que devem ser analisados com maior periodicidade pelos usuários de equipamentos de teleterapia. Os experimentos dosimétricos foram realizados no acelerador linear instalado no Setor Técnico de Radioterapia do Hospital das Clinicas da Faculdade de Medicina de Botucatu. Os ensaios de planura, simetria e de determinação da dose absoluta dos feixes de radiação mostraram-se exequíveis para a rotina da radioterapia veterinária. Os resultados apresentados dos parâmetros radiométricos medidos estão em conformidade com os protocolos de dosimetria nacionais e internacionais. O Plano de Radioproteção elaborado, pode subsidiar os profissionais e autoridades sanitárias envolvidas nas práticas da radioterapia veterinária quanto aos preceitos do uso seguro das fontes radioativas e feixes de teleterapia. / Abstract: The proposal of the work is the elaboration of a Radioprotection Plan and the presentation of the routine of dosimetry procedures of teletherapy beams for the adequacy in radiotherapy services dedicated to veterinary medicine. Presented the main radiometric parameters of the radiation beams that should be analyzed more frequently by users of teletherapy equipment. The dosimetric experiments were performed in the linear accelerator installed in the Technical Section of Radiotherapy of the Clinical Hospital of the Botucatu Medical School. The tests of flatness, symmetry and absolute dose determination of the radiation beams were shown feasible for the routine of veterinary radiotherapy. The presented results of the radiometric parameters measured are in accordance with national and international dosimetry protocols. The Radioprotection Plan elaborated may support the professionals and health authorities involved in veterinary radiotherapy practices regarding the safe use of radioactive sources and teletherapy beams. / Mestre
180

Avaliação dosimétrica da solução fricke gel usando a técnica de espectrofotometria para aplicação na dosimetria de elétrons e nêutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

Mangueira, Thyago Fressatti 31 July 2009 (has links)
Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams.