• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 482
  • 19
  • 9
  • 1
  • Tagged with
  • 513
  • 381
  • 135
  • 121
  • 94
  • 71
  • 50
  • 50
  • 47
  • 40
  • 39
  • 39
  • 38
  • 37
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Development of a Thermoluminescence - Radioluminescence Spectrometer / Desenvolvimento de um Espectrômetro de Termoluminescência - Radioluminescência

França, Leonardo Vinícius da Silva 29 March 2018 (has links)
In this work, initially the radioluminescence (RL) and thermoluminescence (TL) techniques are presented. The radioluminescence is the prompt luminescence emitted by a material under ionizing radiation exposure. The thermoluminescence is the luminescence emitted by a material previously exposed to ionizing radiation when excited by heat. Enegy bands concepts, defects in crystals and the different processes of ionization that take place in matter when exposed to ionizing radiation are briefly discussed in order to present the mechanisms involved in RL and TL processes. The usage of the techniques in characterization of materials and dosimetry is reported, legitimating the importance of the instrument developed. Mechanical and structural parts as well as a description of each component of the instrument are fairly described. The implemented algorithm for controlling the instrument and acquiring data is also discussed. The development of the instrument enabled us to generate temperature ramps with a quite good performance, reaching temperatures up to 500 °C with deviations up to 2 °C, having used heating rates between 0.5 °C/s and 5 °C/s. Calibrations of optical spectrometer used in light collection and irradiation system were carried out. Lastly, TL and RL spectra tests were performed. The RL tests were carried out using several materials which emission spectra are well known by literature, namely, carbon-doped aluminium oxide Al2O3:C, terbium-doped gadolinium oxysulphide Gd2O2S:Tb, europium-doped yttrium oxide Y2O3:Eu and dysprosium-doped calcium borate CaB6O10:Dy. For the TL spectra test, the aluminium oxide doped with carbon Al2O3:C was used. The results of RL and TL spectra tests showed a good agreement with the literature, pointing out that the instrument developed in this work is comparable to others instruments in operation from others research groups, making our results reliable. / Nesse trabalho, inicialmente as técnicas de radioluminescência (RL) e termolumi- nescência (TL) são apresentadas. A radioluminescência é a luminescência imediata emitida por um material quando exposto à radiaçao ionizante. A termoluminescência é a luminescência emitida por um material previamente exposto à radiação quando este é aquecido. Conceitos de bandas de energia, defeitos em cristais e os diferentes processos de ionização que ocorrem na matéria quando exposta à radiação ionizante são brevemente discutidos a fim de apresentar os mecanismos envolvidos na RL e TL. A utilização das técnicas na caracterização de materiais e na dosimetria é reportada, justificando a importância do instrumento desenvolvido. As partes mecânicas/estruturais e uma descrição de cada componente do instrumento são descritos. O algoritmo implementado para controle do instrumento e aquisição de dados é também descrito. O desenvolvimento do instrumento possibilitou a geração de rampas de temperatura com uma boa performance, atingindo até 500 °C com variações de até 2 °C ao utilizar taxas de aquecimento entre 0.5 °C/s e 5 °C/s. Calibrações do espectrômetro óptico utilizado na aquisição da luminescência e do sistema de irradiação foram executadas. Por fim, testes de aquisição de espectros de RL e TL foram realizados. Os testes de RL foram realizados utilizando vários materiais cujos espectros de emissão são bem conhecidos pela literatura, a saber, óxido de alumínio dopado com carbono Al2O3:C , oxisulfeto de gadolínio dopado com térbio Gd2O2S:Tb , óxido de ítrio dopado com európio Y2O3:Eu e borato de cálcio dopado com disprósio CaB6O10:Dy. Para o teste dos espectros de TL, o Al2O3:C foi utilizado. Os resultados dos espectros de RL e TL mostraram concordância com a literatura, indicando que o instrumento desenvolvido é comparável a outros instrumentos em operação de outros grupos, tornando os nossos resultados confiáveis.
202

Metodologia dosimétrica para extremidades em indivíduos ocupacionalmente expostos à radiação  beta por meio da técnica de luminescência opticamente estimulada / Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence technique

Pinto, Teresa Cristina Nathan Outeiro 27 July 2010 (has links)
Uma metodologia dosimétrica foi estabelecida, para determinação das doses recebidas em extremidades por indivíduos ocupacionalmente expostos à radiação beta, com detectores de Al2O3:C e sistema leitor microStar, da Landauer, associados à técnica de luminescência opticamente estimulada (OSL). As principais etapas do trabalho foram: caracterização do material dosimétrico Al2O3:C utilizando a técnica de OSL; estabelecimento de um método para avaliação de dose em extremidades; determinação de taxas de dose de fontes de radiação beta; aplicação do método estabelecido em um teste prático com indivíduos ocupacionalmente expostos à radiação beta durante uma simulação de procedimento de calibração de aplicadores clínicos; validação do método desenvolvido por meio de comparação das doses obtidas no teste prático pela técnica de OSL com doses obtidas pela técnica de TL. Os resultados mostram que os detectores de Al2O3:C e a técnica de OSL podem ser utilizados em monitoração individual de extremidades e radiação beta. / A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al2O3:C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al2O3:C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al2O3:C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation.
203

Desenvolvimento de um sistema de dosimetria para aplicadores de betaterapia de 90Sr+90Y / Dosimetry system development for 90sr+90y betatherapy applicators

Coelho, Talita Salles 17 September 2010 (has links)
Os aplicadores de 90Sr+90Y utilizados no Brasil em betaterapia para prevenção de quelóide e pterígio são importados e suas características dosimétricas são obtidas através de tabelas e manuais dos fabricantes apenas de forma ilustrativa pelos fabricantes. A rotina exaustiva dos profissionais de física médica nos serviços de radioterapia muitas vezes não viabiliza a realização de procedimentos para confirmação destes parâmetros. Este trabalho apresenta o desenvolvimento de uma metodologia para dosimetria de aplicadores de betaterapia de 90Sr+90Y. O software MCNP5 que é baseado no método de Monte Carlo foi utilizado para simulação das curvas de porcentagem de dose profunda e perfis de distribuição de dose produzidos por estes aplicadores. As medidas experimentais da atenuação da radiação, perfil radial e axial, foram realizadas com uma mini-câmara de extrapolação, dosímetros termoluminescentes e filmes radiocrômicos. Os resultados das medidas experimentais foram comparados com os valores simulados. Ambas as curvas de porcentagem de dose profunda e os perfis de distribuição de dose radiais, teóricos e experimentais, apresentaram boa concordância, o que pode validar o uso do software MCNP5 para estas simulações, reforçando a viabilidade do uso deste método nos procedimentos de dosimetria destas fontes emissoras de radiação beta. / The 90Sr+90Y applicators, used in Brazil betatherapy for prevention of keloids and pterigium, are imported and their dosimetric features are obtained through charts and manuals provided only in an illustrated form by the manufacturers. The exhaustive routine of the medical physicists in the clinic often do not make possible the accomplishment of procedures for the confirmation of these parameters. This work presents the development of a methodology for the dosimetry of 90Sr+90Y betatherapy applicators. The MCNP5 software that is based on the Monte Carlo method was used for the simulation of the percentage depth dose curves and dose distribution profiles produced by these applicators. The experimental measurements of the radial and axial radiation attenuation, have been done with a mini-extrapolation chamber, thermoluminescent dosimeters and radiographic films. The experimental results have been compared with the simulated values. Both percentage depth dose curves and the radial dose profiles, the theoretical and the experimental ones, have presented good agreement, which may validate the use of the MCNP5 software for these simulations, confirming the viability of the usage of this method in procedures of beta emitter sources dosimetry.
204

Cinética e dosimetria do [177Lu-DOTA0, Tyr3]octreotato em pacientes com tumores carcinoides / Kinetic and dosimetry [177Lu-DOTA0 ,Tyr3]octreotate in patients with carcinoid tumors

Silva, Ana Claudia Machado 11 August 2014 (has links)
Tumores carcinoides (neoplasias bem diferenciadas) são tumores neuroendócrinos que podem surgir em diferentes locais anatômicos. Na população a prevalência dos tumores carcinoides é de aproximadamente 10 casos para um milhão de habitantes e sua incidência é maior na quinta e sexta década de vida. Este trabalho propõe um modelo cinético baseado na teoria da análise compartimental em humanos com tumores carcinoides que se submeterão ao tratamento com o radiofármaco [177Lu-DOTA0,Tyr3]Octreotato. Imagens cintilográficas dinâmicas planares, obtidas imediatamente à injeção de 370 MBq (10 mCi) do radiofármaco, foram obtidas com o tomógrafo SPECT (Single Photon Emission Computed Tomography). Por meio da seleção de regiões de interesse (ROI) os resultados foram digitalizados e aplicados ao modelo cinético aqui proposto. A primeira fase do estudo (atividade de 370 MBq) teve como objetivo conhecer os parâmetros cinéticos e subsequentemente, o paciente foi submetido ao protocolo de tratamento radioterápico, a critério médico, aos quatro ciclos de 7,4 GBq (200 mCi) do radiofármaco. Desta forma, foi possível estimar previamente as constantes cinéticas ki,j da biodistribuição do 177Lu-DOTATATO no corpo, sendo ki,j a fração de transferência do i-ésimo compartimento (tecido ou órgão) para o j-ésimo compartimento a partir das ROI demarcadoras dos órgãos de maior captação, a saber: fígado, rins, região vascularizada e tumores carcinoides. A partir das constantes cinéticas ki,j a estimativa de dose absorvida em 26 órgãos foi estimada pelo método MIRD. Os resultados dosimétricos foram compatíveis com outras metodologias descritas na literatura. Para um paciente adulto de 73,6 kg, em termos médios seus rins (sem os protetores renais) recebem a maior intensidade de dose (2,39 mGy/MBq) seguido do fígado (0,70 mGy/MBq). Observou-se que tumores com aproximadamente 100g recebem dose da ordem de 0,52 mGy/MBq independentemente da posição a que se encontram no corpo. Este achado se deve à predominância do dano devido às partículas beta quando comparado à radiação gama que possui pouco rendimento de emissão no processo de decaimento do 177Lu. Portanto, os parâmetros cinéticos que promovem a captação do 177Lu nas células são os principais responsáveis pela composição da dose no tumor e demais órgãos. / Carcinoid tumors (well differentiated neoplasms) are neuroendocrine tumors that may arise in different anatomical locations. The population prevalence of carcinoid tumors is approximately 10 cases per one million inhabitants. Its incidence is higher in the fifth and sixth decade of life. This paper proposes a kinetic model in humans with carcinoid tumors who will underwent treatment with the radiopharmaceutical [177Lu-DOTA0,Tyr3 ]OCTREOTATE based on the theory of compartmental analysis. Dynamic planar scintigraphic images acquired immediately upon injection of 370 MBq (10 mCi) of the radiopharmaceutical were obtained with the SPECT (Single Photon Emission Computed Tomography) tomography. Samples from regions of interest (ROI) were used for the kinetic study applying the kinetic proposed model. The first phase of the study (activity 370 MBq) was aimed to evaluate the kinetic parameters. Subsequently, the patient underwent the [177Lu-DOTA0,Tyr3 ]OCTREOTATE radiotherapy protocol, under the physician\'s prescription (up to four cycles of 7.4 GBq (200 mCi)). Thus, it was possible to previously estimate the kinetic constants ki,j relative to biodistribution of [177Lu-DOTA0,Tyr3 ]OCTREOTATE in the body. The ki,j is the transfer fraction from the ith compartment (a tissue or an organ) to the jth compartment. Only few organs showed significant ROI radioactivity count level, among them: the liver, kidney, blood and carcinoid tumors. The MIRD method and the kinetic constants ki,j were used to estimate the absorbed dose in 26 body organs. The absorbed dose D(mGy/MBq) was comparable to other methods described in the literature. For an adult patient of 73.6 kg, on average, the kidneys (without amino acid protectors) showed the highest dose (2.39 mGy/MBq) followed by liver (0.70 mGy / MBq) and tumor (0.52 mGy/MBq) with a tissue size of approximately 100 g. It was observed that tumors receive the same absorbed dose D(mGy/MBq) regardless their position in the body. This finding is due to the predominance of the tissue radiation damage of beta particles compared to gamma radiation that has little yield emission in the 177Lu decay scheme. Therefore, the kinetic parameters ki,j that promote the uptake of 177Lu in cells are primarily responsible for the absorbed D dose in the tumor and other organs.
205

Métodos simplificados para obtenção de distribuição de luz em tecidos biológicos: aplicação para terapia fotodinâmica / Simplified methods for obtaining the light distribution in biological tissues

Moriyama, Lilian Tan 17 June 2011 (has links)
A determinação da distribuição da luz em tecidos biológicos é importante para aplicações tais como a terapia fotodinâmica e o fotodiagnóstico. grande parte das aplicações se baseiam na luz que atinge a superfície do tecido e se propaga ao longo da profundidade. A combinação da absorção e do espalhamento leva aos perfis de intensidade que determinam a ação terapêutica. Os métodos existentes para a prever a distribuição da luz nos tecidos biológicos necessitam da determinação dos coeficientes ópticos do tecido, e demandam longo tempo computacional de modo que a aplicação em tempo real conjugada às fototerapias torna-se impossível. Considerando a terapia fotodinâmica, o contorno da necrose é determinado pela dose limiar. Portanto é importante assegurar uma intensidade de luz acima deste limiar na região onde deseja-se induzir necrose. Esta determinação envolve o conhecimento da distribuição da luz. Nesta tese são apresentados experimentos realizados em meios que simulem o comportamento óptico dos tecidos biológicos para estabelecer uma metodologia empírica para determinar a distribuição da luz. Este método baseia-se em medidas da intensidade de luz como função da posição espacial no interior do meio. Os dados são então armazenados em forma de uma matriz tridimensional. Usando esta matriz, operações matemáticas como soma, translação e rotação são utilizadas para compor diferentes campos de luz, ou seja, diferentes geometrias de iluminação. As medidas experimentais e as previsões teóricas foram comparadas demonstrando que o método proposto pode ser utilizado para recuperar a distrubuição da luz em meios túrbidos para diversas geometrias de iluminação. Experimentos in vivo mostraram que este método pode ser bastante útil na determinação da dosimetria para terapia fotodinâmica. / The determination of light distribution within biological tissues is important for applications such as photodynamic therapy and photodiagnostics. Most applications use light that reaches the tissue surface and propagates along the depth. The combination of absorption and scattering leads to light intensity profiles which determines the therapeutic action. Considering photodynamic therapy, necrosis contour is determined by the threshold intensity. Therefore it is quite important to assure intensity above the threshold at the region where necrosis is desired. This determination involves the knowledge of light distribution. In this study, we have developed an empirical method to determine light distribution in optical phantom. This method is based on experimental measurements of light intensity as a function of position inside the medium. The data were collected for a collimated narrow laser beam and arranged in a tridimensional matrix. Using this matrix, simple mathematical operations were used to simulate different conditions of irradiation geometry. Comparison between experimental measurements and mathematical simulations show that our method can be used to recover light distribution in biological tissue for any condition of illumination, since we have previously performed simple measurements in a sample using a narrow beam. In vivo experiments showed that this method can be very useful to the determination of photodynamic therapy dosimetry.
206

Confecção e caracterização de dosímetro luminescente de óxido de alumínio dopado com magnésio. / Luminescence dosimeter based on magnesium doped aluminum oxide: production and characterization.

Bitencourt, José Francisco Sousa 09 June 2008 (has links)
O objetivo desse trabalho é confeccionar e caracterizar dosímetros luminescentes de óxido de alumínio, dopados com o elemento químico magnésio, para aplicação em dosimetria das radiações ionizantes. O óxido de alumínio é obtido pelo método do precursor polimérico; através da obtenção de resina polimérica que resulta em material cerâmico em pó após tratamentos térmicos em temperaturas específicas. As análises dosimétricas são realizadas durante ciclos de aquecimento de amostras que já tenham absorvido certa quantidade de radiação ionizante, ou dose radioativa, é a chamada Termoluminescência. Neste trabalho as fontes radioativas são emissoras de radiação- ou raios-X, que são mais presentes nos campos da radioterapia, radiodiagnóstico, geração de energia elétrica e estudos científicos. Devido às propriedades físicas do cristal, ocorre emissão de luz quando elétrons e buracos recebem energia térmica, permitindo a sua liberação de estados quânticos meta-estáveis e a recombinação com cargas opostas, liberando fótons no espectro UV/visível. A análise química por ICP AES indica as concentrações de 0,47; 0,88; 1,33; 2,61 e 3,36 mol% de Mg2+ para as cinco amostras preparadas com diferentes massas do reagente MgCO3; estes valores indicam que o procedimento para obtenção das amostras foi realizado com uniformidade adequada e, portanto, os resultados alcançados são proporcionais às concentrações de Mg2+. Inicialmente, analisando os resultados da difração de Raios-X, percebe-se que a menor temperatura utilizada para a calcinação do material cerâmico não foi suficiente para que se obtivesse a fase estrutural desejada (fase alfa), uma vez que a estrutura gama não exibiu propriedades dosimétricas para doses baixas. Este fato implicou em tratamentos térmicos adicionais em temperatura superior (1100°C). Os difratogramas obtidos comprovam a viabilidade do processo e metodologia, com amostras altamente cristalinas e ausência de fases desconhecidas que poderiam ocorrer caso houvesse contaminação. As medidas de TL acusaram uma forte emissão luminescente na região do espectro visível e UV, com picos de emissão em 125, 200, 280, 350 e 430°C, aproximadamente. Os últimos não puderam ser estudados para doses baixas, pois suas intensidades são sobrepostas pela incandescência do porta amostras. Entretanto, o pico de emissão em 200°C mostrou comportamento satisfatório e, portanto, empregado para estudos mais aprofundados. Os picos de alta temperatura (280, 360 e 430ºC) exibiram ótima resposta luminescente para altas doses absorvidas (acima de 100 Gy), sem que seu ponto de saturação fosse alcançado para doses de até 1 kGy. Variando sensivelmente a energia do feixe de irradiação foi possível determinar que a luminescência do material apresenta baixa dependência energética para energias abaixo de 40 keV, o que está de acordo com a teoria de interação energia/matéria. Acima desta energia, há diminuição do fenômeno fotoelétrico em detrimento do espalhamento Compton. As imagens obtidas por Microscopia Eletrônica de Transmissão detectaram, nas amostras dopadas, a presença de estruturas superficiais compostas por espinélio (MgAl2O4) sobre aglomerados de Al2O3. Este resultado faz crer que a ocorrência desta camada superficial aumenta significativamente a concentração de centros de recombinação e, conseqüentemente, a intensidade de emissão também é aumentada. / The aim of the present work is to obtain and characterize luminescent dosimeters made of magnesium doped aluminium oxide, for ionizing radiation dosimetry purposes. The material is produced by Pechini Method (US Patent 3.330.697, 1967), starting from a polymer that generates powder ceramic, after firing at predetermined temperatures. Dosimetric measurements were taken during heating cycles (Thermoluminescence) with gamma and X-rays irradiated samples. Due to physical properties of the crystal, light is emitted during heating, because of free carriers being released from trap centers and recombining with opposite sigh charges. Chemical analysis indicated the Mg2+ concentrations 0.47, 0.88, 1.32, 2.61 and 3.36 mol%; reactants masses and process parameters were adequate to obtain uniformity. From X-Ray Diffraction, samples calcinated at lower temperatures did not reach the properly structural phase. The gamma phase did not show dosimetric properties for the preferred spectra (UV/visible region). Calcinations at higher temperatures were necessary to obtain alpha phase, which exhibited TL emission. For doped sample, diffractograms indicated the occurrence of highly crystalline sample. TL glow curves showed high visible and UV emission, with peaks at 125, 200, 280, 365 and above 450°C. The lowest peak was faded within 24 hours after irradiation and those above 280°C could not be exactly determined due to peak overlapping. Nevertheless, the emission peak at 200°C showed itself a great achievement for the present work, because of its energy depth and dose response. For higher absorbed doses (above 100 Gy), the emission generated by deeper traps could be studied with more details: acceptable TL response and exponential growth were exhibited. The peak at 280 was not reported. Low energy dependence luminescence in observed for doses as high as 40 keV. This limitation is due to decreasing of photoelectric phenomena, which is responsible for charges trapping. Images obtained using Transmission Electron Microscopy detected surface layer in doped samples; such layer is composed by spinel (MgAl2O4). The presence of spinel layer increases recombination centers concentration, once luminescence enhancement was perceived for doped samples.
207

Desenvolvimento de um novo gel e otimização de leitor para dosimetria química / New gel and Fricke reader for chemical dosimetry.

Zaias, Herofen 26 June 2006 (has links)
O interesse científico em se conhecer os efeitos provocados pelo uso da radiação ionizante nos sistemas biológicos, fez com que a área da dosimetria merecesse uma atenção especial na busca de sensores que pudessem traduzir respostas equivalentes às dos tecidos humanos. O presente trabalho mostra a caracterização preliminar e a aplicação de um novo dosímetro químico (FXGA), derivado do FXG, que se diferencia do anterior pela substituição da gelatina de pele de porco \"300 Bloom\" por uma nacional. As leituras de dose absorvida por esse dosímetro são baseadas na absorção ótica e para tal foi desenvolvido um protótipo portátil (RADIARE III), que se mostrou prático e acessível economicamente em relação a um espectrofotômetro. A partir das medidas realizadas pode-se inferir que o dosímetro FXGA possui comportamento linear com a dose absorvida no intervalo de 0,5 à 35 Gy para fótons do 60Co, e de 1 à 7 Gy para elétrons com energias de 5, 8 e 10 MeV. Também a dependência energética para fótons e elétrons foram obtidas e seus comportamentos são coerentes com o esperado. Aplicações na radioterapia foram obtidas, como: perfil, fator de campo e percentual de dose profunda para fótons do 60Co. Dos resultados obtidos da caracterização para fótons e elétrons, bem como dos parâmetros físicos para o equipamento 60Co, o sistema dosimétrico \"gel FXGA + protótipo RADIARE III\" mostrou-se promissor para ser utilizado no controle de qualidade de um serviço de radioterapia. / Researchs with radiation dosimeters look for materials that presents similar response to radiation as biological systems. This work presents preliminar characterization and radiotherapy application from a new chemical dosimeter (FXGA), derived from the FXG with a difference due to the gelatin used (pork skin \"300 Bloom\" for FXG and national gelatin for FXGA). The FXGA absorbed dose reading are based on the optic absorption, and for this reason a reader (RADIARE III) was developed, which is portable and economically accessible when compared with an spectrophotometer. From the measurements done, it can be inferred that FXGA dosimeter possess linear response with the absorbed dose from 0.5 up to 35 Gy for 60Co photons and from up 1 up to 7 Gy for 5, 8 and 10 MeV. The energy dependence for photons and electrons were obtained and their response are coherent those expected. FXGA radiotherapy applications had been done as field factor, profile and percentage depth dose for 60Co photons. From the characterization results for photons and electrons, as well from physical parameters for the 60Co , one can figure out that the dosimetric system \"FXGA gel + RADIARE III reader\" can be an attractive tool for the quality control in a radiotherapy service.
208

Influência de nanoestruturas na resposta dosimétrica de compósitos particulados de alanina/ouro e alanina/prata / Nanostructure Influence in the Dosimetric Response of Alanine/Gold and Alanine/Silver Particulate Composites

Guidelli, Éder José 28 July 2011 (has links)
A interação da radiação ionizante com moléculas de alanina promove a quebra das ligações químicas entre o átomo de carbono central e os grupos que se ligam a ele, resultando na formação de radicais livres paramagnéticos. A técnica de dosimetria utilizando alanina e a ressonância de spin eletrônico (ESR) baseia-se na determinação da concentração dos radicais livres produzidos pela interação da radiação ionizante com as moléculas da alanina por meio do registro do espectro de ESR da alanina irradiada. Para propósitos de dosimetria, a amplitude da linha central do espectro pode ser correlacionada diretamente com a dose de radiação. Na atualidade, a alanina/ESR é uma técnica de dosimetria amplamente aceita para a dosimetria de altas doses como aquelas usadas nos processos de irradiação de alimentos, esterilização de produtos médicos e radioterapia. A expansão dos tratamentos de câncer por meio de procedimentos de radiocirurgia e radioterapia de intensidade modulada (IMRT) torna cada vez mais relevante a necessidade de realizar a dosimetria em pequenos campos de radiação. Para a dosimetria desses feixes estreitos de radiação, é necessário o uso detectores que também apresentem dimensões reduzidas de forma a proporcionar alta resolução espacial. Uma vez que a sensibilidade dos dosímetros de alanina depende do número de radicais formados pela radiação, a redução do tamanho do detector de alanina implica em redução de seu volume sensível e consequentemente de sua sensibilidade. Assim, pesquisas têm sido realizadas buscando uma melhora de sua sensibilidade. Neste trabalho foram investigados os mecanismos envolvidos na formação da nanoestrutura e a capacidade da alanina em estabilizar e acomodar nanopartículas metálicas de ouro e prata em sua matriz cristalina, para aplicação dos nanocompósitos como detectores de radiação utilizando a técnica de ressonância de spin eletrônico. Foi analisado o tamanho das partículas, sua interação com as moléculas do aminoácido, sua agregação e posicionamento dentro da matriz cristalina da alanina. Além disso, foi investigada a maneira como a morfologia e o estado de agregação e segregação das nanopartículas podem alterar a resposta dosimétrica dos detectores híbridos de alanina. O aumento de sensibilidade dos dosímetros de alanina mostrou estar diretamente associado ao aumento do número de elétrons ejetados por efeito fotoelétrico. No entanto, foi mostrado que aumento da sensibilidade dos dosímetros de alanina é governado por outros fatores além do número de eventos fotoelétricos. A auto-absorção dos elétrons oriundos de uma nanopartícula metálica, por outra nanopartícula vizinha, também influencia na resposta dosimétrica do detector. Assim, sistemas homogêneos onde não houve segregação, apresentaram menor auto-absorção e, consequentemente, os ganhos em sensibilidade foram maiores. Para sistemas onde houve aumento de tamanho e segregação das partículas metálicas, a auto-absorção se tornou mais relevante. Para fótons com energias próximas a energia da camada K do metal presente no nanocompósito, a absorção da radiação foi muito mais relevante do que a organização das nanopartículas na estrutura da alanina. Para energias maiores a probabilidade de eventos fotoelétricos somente diminui e, dessa forma, a agregação e segregação das partículas desempenharam papéis fundamentais na sensibilidade dos dosímetros. Assim, a sensibilidade dosimétrica dos detectores pode ser aumentada e otimizada por meio do uso da nanoestruturação, reduzindo a auto-absorção dos elétrons ejetados. / The interaction of ionizing radiation with alanine molecules produces free radicals. The room temperature stable alanine radical is molecule depleted of the amine group. The Alanine/ESR dosimetry technique is able to measure the amount of free radicals produced by the radiation. For dosimetric purposes, the amplitude of the central ESR spectral line is direct related to the absorbed dose by the alanine molecules. Nowadays, the alanine/ESR technique is largely used for dosimetry of high doses such as used in food irradiation, sterilization of medical products and radiotherapy. The growing need for cancer treatments using radiosurgery and intensity modulated radiation therapy (IMRT) makes important the dosimetry of small radiation fields. To this end, it is necessary to use small radiation detectors in order to obtain enough special resolution. Once the sensitivity of alanine dosimeters depends on the amount of free radical produced by the radiation, reducing the size of alanine detector also reduces its sensitivity. Thus there is an intense investigation to develop high sensitivity of Alanine/ESR dosimeters. In this work the mechanisms involved in the formation of nanostructures and the ability of alanine to stabilize and accommodate nanoparticles of silver and gold in its crystalline matrix, for applications of the nanocomposite as radiation detectors was investigated using the electron spin resonance technique. The effect of particle size, its interaction with alanine molecules, aggregation and segregation of particles inside the alanine matrix as well as the way the morphology and the state of agglomeration change the dosimetric sensitivity of the alanine detectors were investigated. The increase of sensitivity of the alanine detectors was direct related to the amount of photoelectric events in the nanocomposite. However, the self-absorption of the electrons ejected by one particle, by another nanoparticle in the vicinity, also dictates the sensitivity of the detectors. In this sense, homogeneous systems presented less self-absorption and, consequently, the increase in sensitivity was higher. For systems containing aggregated and segregated particles, self-absorption becomes more relevant. For incident photons with energies near de K-edge of the metal of the nanocomposite, the number of photoelectric events was more relevant than the organization of the particles inside the alanine crystals. For higher energies the probability of a photoelectric interaction decreases, therefore the aggregation and segregation of particles become essential in determining the sensitivity of the dosimeters.
209

Luminescência opticamente estimulada com aplicações em radioterapia: dependência da dose absorvida e da energia de fótons produzidos em aceleradores clínicos e Microtron - IFUSP / Optically stimulated luminescence with applications in radiotherapy: dependence of absorbed dose and photon energy produced on clinical accelerators and Microtron - IFUSP

Freitas, Carlos Eduardo 28 April 2017 (has links)
Atualmente a utilização de fótons de raios X e gama na Medicina (radiodiagnóstico e radioterapia) gerou a necessidade do conhecimento da dose absorvida nos tecidos dos pacientes. Para isso, utiliza-se detectores com diversas funcionalidades a fim de conhecer a deposição de energia. Para ser possível a utilização destes materiais, é necessário caracterizá-los tanto quanto à resposta em função da dose absorvida, quanto à dependência com a energia. Neste trabalho foi estudada a dependência energética da resposta OSL dos dosímetros compostos por BeO e Al2O3 em feixes de raios X convencional com espectro largo, feixes de raios X de aceleradores clínicos e do acelerador Microtron do Instituto de Física da USP e fontes gama de Cs-137 e Co-60, em uma faixa de doses desde centenas de mGy até aproximadamente 2 Gy. Foram utilizadas em conjunto simulações em Monte Carlo com o código PENELOPE, que simula o transporte de fótons e elétrons na matéria, a fim de conhecer a deposição de energia nos materiais. Os espectros utilizados nas simulações foram validados através da comparação das características dos feixes tais como a deposição de dose com a profundidade, camada semirredutora, energia média e resolução espectral. Utilizando um sistema de varredura por câmara de ionização controlado remotamente, foi estudada a distribuição de doses no campo de irradiação para definir uma região de irradiação com dose uniforme para pode realizar a irradiação de um conjunto de dosímetros simultaneamente. Foram encontrados valores do fator de dependência energética experimental para os feixes mais energéticos (Co-60, Microtron 5 MeV e aceleradores clínicos de 6 e 15 MeV), com desvio menor que 3% para o Al2O3 e 5% para o BeO, indicando independência com a energia do feixe de irradiação. Já nos feixes de baixa energia, os fatores de dependência energética relativos à energia do Co-60 para o Al2O3 foram de 1,68 e 1,42, e, para o BeO, de 0,78 e 0,90 para os feixes W150 e W200 respectivamente. Estes valores indicam que, nesta faixa de energia, a resposta OSL depende mais fortemente da energia do feixe. As simulações em Monte Carlo feitas para os fatores de dependência energética se mostraram bem consistentes com os valores experimentais para o BeO em toda faixa de energia e para o Al2O3, excetuando-se os feixes de baixa energia, possivelmente pelo não completo conhecimento de todos os elementos constituintes do dosímetro empregado (fita de Luxel®). Quanto às curvas de emissão OSL para as diferentes energias de irradiação, foi observado que o sinal decai mais rápido quanto mais elevada é a energia média do feixe para o BeO. Para o Al2O3, o efeito foi mais sutil e oposto. Os estudos do feixe do Microtron mostraram que, desde que a corrente seja monitorada durante as irradiações para posterior correção da dose, é possível realizar estudos utilizando um feixe de fótons de Bremsstrahlung produzido com alvo externo e energias médias (simuladas e ainda não validadas experimentalmente) próximas às energias das fontes gama de Cs-137 e Co-60. Os resultados experimentais para as respostas OSL dos dois materiais foram compatíveis com as simulações. / Nowadays the use of X and gamma-ray photons in Medicine (radiodiology and radiotherapy) has generated the necessity of knowing the absorbed dose to the tissues of patients. For this purpose, detectors with diverse functionalities are used to know the energy deposition. To make possible the use of these materials, it is necessary to characterize the dose response, as well as the energy dependence of the response. In this work the energy dependence of the OSL response of the BeO and Al2O3 dosimeters was studied for conventional X-ray beams with wide energy spectrum, X-ray beams from clinical accelerators and from the Microtron accelerator of the Institute of Physics (University of São Paulo), and for gamma sources of Cs-137 and Co-60, in a dose range from hundreds of mGy to about 2 Gy. Monte Carlo simulations were used with the PENELOPE code, which simulates the photons and electrons transport of in the matter, to know the energy deposition in the materials. The energy spectra used in simulations were validated by comparison with beam characteristics such as depth dose deposition, half-value layer, mean energy and spectral resolution. Using a remotely controlled ionization chamber scanning system, the dose distribution within the irradiation field was evaluated to define a uniform dose region for irradiation or a set of dosimeters simultaneously. Experimental energy dependence factor values were obtained for the high-energy beams (Co-60, Microtron 5 MeV, and clinical accelerators of 6 and 15 MeV), with a deviation of less than 3% for Al2O3 and 5% for BeO, indicating independence with the beam energy. For the low-energy X-ray beams, the energy dependence factors, relative to the Co-60 energy, for Al2O3 were 1.68 and 1.42, and, for BeO, 0.78 and 0.90 for W150 and W200 beams respectively. These values indicate that, in this energy range, the OSL response depends on beam energy. Monte Carlo simulations for the energy dependence factors were consistent with experimental values for the BeO in entire energy range and for the Al2O3, with the exception of low energy beams, possibly due to the incomplete knowledge of all the elements that constitute the Luxel®. As for the shape of OSL emission curves for the different irradiation energies, it was observed that the signal decays faster the higher is the average beam energy for BeO. For Al2O3, the effect was more subtle and opposite. The Microtron beam scanning has shown that, as long as the current is monitored during irradiation for further dose-rate correction, it is possible to carry out studies using a beam of Bremsstrahlung photons produced with external target and mean energies (simulated but still not validated experimentally) close to the energies of the Cs-137 and Co-60 sources. The experimental results for the OSL responses of both materials were compatible with simulations.
210

Estudo e validação da dosimetria em condições de não-referência / Estudy and validation of dosimetry in non-reference conditions

Sabino, Talita 12 July 2011 (has links)
Com o avanço tecnológico dos equipamentos utilizados em radioterapia tornaram-se possíveis o uso de alguns campos de radiação nomeados como campos pequenos em algumas modalidades especiais de radioterapia. Com isso, a dosimetria dos feixes de radiação também teve de ser revista, pois com estes novos tamanhos de campos, não há condição de referência como aquela dita nos protocolos e diretrizes de dosimetria. Neste trabalho foi realizado um estudo completo sobre os campos pequenos, bem como sua dosimetria, mostrando o comportamento dos detectores nessa nova condição de dosimetria através de uma comparação entre os detectores utilizados e dados já publicados na literatura. Além disso, os dados obtidos experimentalmente puderam ser validados através de comparação com dados publicados por outros autores. Na caracterização do detector de diamante o mesmo apresentou-se apropriado em todos os parâmetros para medidas com campos pequenos. Na análise do fator de qualidade Q os resultados experimentais obtidos nesta investigação mostraram diferenças percentuais de 1,8%; 4,0% e 4,9% para câmara do tipo CC01, CC13 e diodo estereotáxico respectivamente. Na avaliação de PDP e TMR foi possível observar a dificuldade nas medições com campos pequenos bem como na comparação de diferentes detectores, para PDP a maior diferença foi de 2,6% e para TMR 2,7%. / With the technological equipment used in radiotherapy became possible use of some radiation fields named small fields in some special forms of radiotherapy. Thus, the dosimetry of radiation fields also had to be revised, as with these new sizes of fields, there is no reference condition such as that expressed in dosimetry protocols and guidelines. This work represents a complete study of small fields and its dosimetry, showing the behavior of the detectors in this new condition of dosimetry through a comparison between the detectors used and data already published. Moreover, the experimental data can be validated by comparison with data published by others authors. In the characterization of the same diamond detector has been considered appropriate in all parameters measured with small fields. The analysis of the beam quality factor (Q) the experimental results obtained in this study showed differences in percentages of 1.8%, 4.0% and 4.9% for chamber-type CC01, CC13 and stereotactic diode respectively. In evaluating PDP and TMR was possible to observe the difficulty in measurements with small fields and the comparison of different detectors, the biggest difference for PDP was 2.6% and 2.7% for TMR.

Page generated in 0.0384 seconds