• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 10
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Incorporação de placas de metal duro em peças fundidas

Barbosa, André Miguel Azevedo January 2008 (has links)
Estágio realizado na DURIT-Metalurgia Portuguesa do Tungsténio, Ld.ª / Tese de mestrado integrado. Engenharia Metalúrgica e de Materiais. Faculdade de Engenharia. Universidade do Porto. 2008
2

Estudo da estrutura e comportamento tribológico de revestimentos duros e ultra-duros executados no vácuo

Silva, Francisco José Gomes da January 2001 (has links)
Dissertação apresentada para obtenção do grau de Doutor em Engenharia Mecânica, na Faculdade de Engenharia da Universidade do Porto, sob a orientação dos Professores Doutores António Paulo Monteiro Baptista e Maria Estela M. F. Pereira
3

Comportamento tribológico de filmes duros depositados por PAPVD em substrato de metal duro / Cleomar Schmitz ; orientador, Ricardo Diego Torres ; co-orientador, Carlos José Mesquita Siqueira

Schmitz, Cleomar January 2006 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2006 / Inclui bibliografia / O desempenho em serviço de peças ou ferramentas revestidas está diretamente ligado às propriedades do material do filme, a adesão ao substrato, microdureza e coeficiente de atrito. Neste trabalho foi investigado o comportamento do coeficiente de atrito de / The performance in service of parts or coated tools is directly on to the properties of the material of the film, the adhesion of the substrate, microhadness and friction coefficient. In the case of the deposition of nitrete and carbonitrete of in hard me
4

Obtenção da relação π°→+ 2y E y → 3π

Santos, Gonçalo Rodrigues dos, Instituto de Engenharia Nuclear 11 1900 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-09-27T16:16:04Z No. of bitstreams: 1 GONÇALO RODRIGUES DOS SANTOS M.pdf: 1459969 bytes, checksum: 8b3fc490a0a359784ab9aa180749a587 (MD5) / Made available in DSpace on 2017-09-27T16:16:04Z (GMT). No. of bitstreams: 1 GONÇALO RODRIGUES DOS SANTOS M.pdf: 1459969 bytes, checksum: 8b3fc490a0a359784ab9aa180749a587 (MD5) Previous issue date: 1982-11 / Estudamos a amplitude de desintegração y → 3π usando o método de pions duros da álgebra de correntes baseado na técnica das identidades de Ward do grupo quiral SU (2) XSU (2). Este método conduziu a uma expressão geral relacionando os processos y → 3π c π°→ 2y que possibilita reobter, no limite de pions moles, a relação de Adler e introduzir nela correções através do propagador vetorial e do fator de forma eletromagnético do pion.
5

Projeto ótico de linha de luz de raios-X duros para cristalografia de proteínas / Optical design of a hard X-ray beamline to protein crystallography

Grizolli, Walan Cesar 16 August 2018 (has links)
Orientador: Antônio Rubens Britto de Castro / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-16T08:21:17Z (GMT). No. of bitstreams: 1 Grizolli_WalanCesar_M.pdf: 22164883 bytes, checksum: 87cb39dcd42129ec1d9a3f9ec6fcba09 (MD5) Previous issue date: 2010 / Resumo: Diversas áreas da ciência moderna têm sido beneficiadas pelo uso da radiação síncrotron. As técnicas disponveis em laboratórios deste tipo abrangem pesquisas em ciências básicas como Física, Química e Biologia bem como em áreas como engenharia de materiais e farmacologia. Em particular, o uso do espectro de raios-x duros (8-20keV) das fontes síncrotron atuais e crucial para técnicas estruturais como difração e cristalografia. Estas técnicas estão disponíveis para a comunidade científica brasileira no Laboratório Nacional de Luz Síncrotron (LNLS), cujas linhas de luz estão abertas a usuários externos desde 1997. As instalações do LNLS vem sendo constantemente aperfeiçoadas, permitindo o estudo de novos casos científicos como consequência destas melhorias. Neste trabalho estudamos as propriedades da fonte de radiação síncrotron do LNLS e realizamos um projeto óptico para uma linha de luz direcionada a cristalografia de proteínas. Com uso de simulações computacionais propomos opções para melhoria do fluxo de flotons nas linhas de cristalografia de proteínas já existentes. Nossos estudos apontam para a viabilidade de construção de uma linha lateral a linha de luz MX2, utilizando a mesma fonte Wiggler já instalada, com fluxo proporcional à linha central. / Abstract: Distinct research fields in modern science have taken advantage of synchrotron radiation. The techniques that are available in such laboratories have a very broad scope, ranging from basic sciences such as Physics, Chemistry and Biology, to applied fields as engineering and pharmacology. In particular, the use of hard x-ray spectrum (8-20keV) from modern synchrotron sources is crucial for structural techniques such as diffraction and crystallography. These techniques have been available to the Brazilian scientific community since 1997, when the Brazilian Synchrotron Light Laboratory (LNLS) facilities were opened to external users. The LNLS beamlines have constantly evolved , allowing the users to perform novel experiments as a consequence of instrumental improvements. In this work we study the properties of the LNLS sources and propose solutions for the optics of a beamline dedicated to protein crystallography. By using computer simulations we propose options to enhance the photon flux in the pre-existing protein crystallography beamlines. Our results point out to the feasibility of a lateral beamline using the MX2 wiggler source, with similar flux to the central beamline. / Mestrado / Física / Mestre em Física
6

Prevalencia de patologías bucales en bebés atendidos en el programa de seguimiento del niño de alto riesgo del INMP durante el período enero 2016 – diciembre 2017 / Prevalence of oral pathologies in babies served in the high risk child monitoring program of INMP during the period January 2016 – December 2017

Soto Barrera, Milagros de Pilar 15 March 2019 (has links)
Objetivo: Determinar la prevalencia de patologías bucales en bebés atendidos en el programa de seguimiento del Niño de Alto riesgo del INMP durante el período Enero 2016 a Diciembre 2017 Materiales y métodos: Se recolectó la información de 455 historias clínicas de pacientes pertenecientes al programa de atención estomatológica Niños de Alto Riesgo en el consultorio de Odontopediatría del Instituto Nacional Materno Perinatal. Los datos fueron analizados mediante estadística descriptiva para el análisis univariado donde se aplicaron las medidas estadísticas de frecuencia absoluta y relativa, y análisis bivariado donde se aplicó la prueba de Chi2 y Exacta de Fisher (α=0,05). Resultados: Del total de 455 pacientes, 319 (70.11%) fueron diagnosticados con patologías orales y 136 (29.89%) con boca sana. Además; 127 presentaron patologías en el tejido blando (39.81%) y 192 en el tejido duro (60.19%), siendo este último el más prevalente. Del total de 24 patologías encontradas en la cavidad oral de esta población, las tres más prevalentes fueron síndrome de erupción (18.24%), defecto de desarrollo del esmalte (17.14%) y anquiloglosia (12.97%). Conclusiones: La prevalencia de los pacientes con patologías bucales fue alta (70.11%) y pacientes diagnosticados con boca sana (29.89%). / Objective: The aim of this study was to determine the prevalence of oral pathologies in babies treated in the follow-up program of the High Risk Child of the INMP during the period January 2016 to December 2017 Materials and methods: Information was collected from 455 medical records of patients belonging to the stomatological care program Children of High Risk in the pediatric dentistry office of the National Maternal and Perinatal Institute. The data were analyzed by means of descriptive statistics for the univariate analysis where statistical measurements of absolute and relative frequency were applied, and bivariate analysis where the Chi2 and Fisher Exacta test were applied. (α = 0.05). Results: Of the total of 455 patients, 319 (70.11%) were diagnosed with oral pathologies and 136 (29.89%) with a healthy mouth. Further; 127 presented pathologies in the soft tissue (39.81%) and 192 in the hard tissue (60.19%), the latter being the most prevalent. Of the total of 24 pathologies found in the oral cavity of this population, the three most prevalent were eruption syndrome (18.24%), enamel development defect (17.14%) and ankyloglossia (12.97%). Conclusions: The prevalence of patients with oral pathologies was high (70.11%) and patients diagnosed with healthy mouth (29.89%). / CAPÍTULO 1: INTRODUCCIÓN…………………………………………… CAPÍTULO 2: PLANTEAMIENTO DE LA INVESTIGACIÓN………….. 2.1. Justificación…………………………………………………………… CAPÍTULO 3: OBJETIVOS…………………………………………………. 3.1. Objetivo general………………………………………………………. 3.2. Objetivos específicos………………………………………………… CAPÍTULO 4: MATERIALES Y MÉTODOS……………………………….. 4.1 Diseño del estudio……………………………………………………... 4.2 Población y/o Muestra………………………………………………….. 4.3 Operacionalización de variables………………………………………. 4.4 Técnicas y/o procedimientos………………………………………….. 4.5 Plan de análisis…………………………………………………………. 4.6 Consideraciones éticas…………………………………………………. CAPÍTULO 5: RESULTADOS…………………………………………………. CAPÍTULO 6: DISCUSIÓN…………………………………………………….. CAPÍTULO 7: CONCLUSIONES………………………………………………… CAPÍTULO 8: REFERENCIAS BIBLIOGRÁFICAS…………………………………. ANEXOS……………………………………………………………………. / Tesis
7

Influência da irradiação com laser de Er, Cr:YSGG na resistência de união de sistemas adesivos em esmalte e dentina / Er,Cr:YSGG laser irradiation influence on enamel and dentin bond strength of adhesive systems

Botta, Sergio Brossi 04 June 2007 (has links)
Este trabalho teve o objetivo de avaliar a resistência adesiva de sistemas adesivos baseados no condicionamento prévio com ácido fosfórico (etch-and-rinse) e auto-condicionantes (de um e dois passos) ao substrato dental, submetido a diferentes condições de irradiação com laser de Er,Cr:YSGG. Amostras de esmalte e dentina foram obtidas do terço médio da face vestibular de 216 incisivos bovinos, divididos aleatoriamente em 18 grupos (n=12), de acordo com o substrato, (esmalte e dentina), sistema adesivo (etch-and-rinse, auto-condicionante de um passo e auto-condicionante de dois passos) e condições de irradiação (sem irradiação ? controle, irradiado com refrigeração ar-água e irradiado sem refrigeração ar-água). Em seguida foi realizada inclusão e polimento, sob refrigeração, com lixas de carbeto de silício de granulação decrescente 180, 320, 400 e 600 (por um minuto para padronização da camada de esfregaço). Para os grupos irradiados com laser de Er,Cr:YSGG (?=2,79 ?m, taxa de repetição de 20 Hz), com densidade de energia de 2,8 J/cm2, 12,5 mJ por pulso, potência média de 0,25W, com a ponta S75 de diâmetro de 750 ?m a 1 mm da superfície do substrato. A condição de refrigeração da irradiação foi realizada com 11 mL/min. Os corpos-de-prova foram confeccionados com a resina composta Filtek Z250, em forma de cone invertido para realização do teste de resistência adesiva. Após 24 h de armazenagem em água destilada a 37ºC, fez-se o ensaio de tração a 0,5 mm/min. Os dados foram comparados estatisticamente pelo método de ANOVA com significância de 5%. Os resultados obtidos mostraram que para o tecido esmalte foi observada diferença estatisticamente significante para os fatores adesivo e condições de irradiação empregadas, sem significância para a interação entre os fatores. A resistência de união do sistema adesivo auto-condicionante de dois passos e do sistema adesivo etch-and-rinse apresentam desempenho semelhante, sendo superiores ao sistema adesivo auto-condicionante de passo único. Ainda para esmalte, o efeito das condições de irradiação mostrou que os grupos sem irradiação com laser de Er,Cr:YSGG apresentaram maior resistência adesiva do que os grupos irradiados com refrigeração e sem refrigeração. Para o substrato dentina, houve diferença estatisticamente significante para os fatores de variação principais: sistemas adesivos, condição de irradiação com laser de Er,Cr:YSGG e para a interação adesivo X condição de irradiação. Quanto à comparação entre os sistemas adesivos testados na condição sem irradiação, os sistemas adesivos auto-condicionantes, de dois passos e o de um passo, não foram estatisticamente diferentes entre si, porém ambos forneceram resultados de resistência adesiva estatisticamente menores do que o sistema adesivo etch-and-rinse. Para as condições de irradiação com laser de Er,Cr:YSGG, com refrigeração e sem refrigeração, obteve-se valores de resistência adesiva maiores para o sistema auto-condicionante de dois passos do que para os demais sistemas. Deste modo, conclui-se que a irradiação com laser de Er,Cr:YSGG reduz a adesão ao esmalte independentemente do sistema adesivo utilizado e da condição de irradiação. Adicionalmente, observa-se que a irradiação de dentina com laser de Er,Cr:YSGG somente não altera a resistência adesiva do sistema auto-condicionante de dois passos, sendo deletéria aos demais adesivos testados. / The aim of this study was to assess the bond strength to dental substrate of adhesives based on previous etching with phosphoric acid (etch-and-rinse) and self-etching (one- and two-step) under different conditions of Er,Cr:YSGG laser irradiation. Enamel and dentin samples were obtained from the middle third of the buccal face of 216 bovine incisors, randomly divided in 18 groups (n=12), according to the substrate (enamel and dentin), adhesive system (etch-and-rinse, one-step self-etching and two-step self-etching) and irradiation condition (without irradiation ? control, irradiated with cooling, and irradiated without cooling). Next, the samples were included and polished, under cooling, with silicone carbide abrasive papers of decreasing grit #180, 320, 400 and 600 (for one minute to standardize the smear layer). For the irradiated groups with Er,Cr:YSGG laser, an energy density of 2.8 J/cm2, 12.5 mJ per pulse, mean power of 0.25W was selected. During laser irradiation, cooling was performed with 11 mL/min. Inverted cone-shaped test specimens were built-up with resin composite Filtek Z250, for performing the bond strength test. After 24 h storage in distilled water at 37ºC, the tensile test was performed at 0.5 mm/min. The results obtained show, for enamel, statistically significant difference for the factors adhesive and irradiation conditions used, without significance for the interaction among the factors. The bond strength of the 2-step self-etching and the etch-and-rinse adhesive system presented similar performance, being superior to that of one-step self-etching system. For enamel, the effect of the irradiation conditions showed that the groups without Er,Cr:YSGG laser irradiation presented higher bond strength than the groups irradiated with and without cooling. For the dentin substrate there was statistically significant difference for the main variation factors: adhesive systems, condition of Er,Cr:YSGG laser irradiation and for the interaction adhesive X irradiation condition. As regards the comparison among the adhesive systems tested under the condition without irradiation, the one-step and two-step self-etching adhesive systems did not differ statistically between them, but both provided statistically lower bond strength results than the etch-and-rinse adhesive system. For the condition of Er,Cr:YSGG laser irradiation with and without cooling, higher bond strength values were obtained for the two-step self-etching system than for the other systems. Therefore, it was concluded that Er,Cr:YSGG laser irradiation reduces the bond strength to enamel irrespective of the adhesive system used and the irradiation condition. Furthermore, it was observed that dentin irradiated with Er,Cr:YSGG laser did not alter the bond strength of the two-step adhesive system only, and it was deleterious to the other adhesives tested.
8

Influência da irradiação com laser de Er, Cr:YSGG na resistência de união de sistemas adesivos em esmalte e dentina / Er,Cr:YSGG laser irradiation influence on enamel and dentin bond strength of adhesive systems

Sergio Brossi Botta 04 June 2007 (has links)
Este trabalho teve o objetivo de avaliar a resistência adesiva de sistemas adesivos baseados no condicionamento prévio com ácido fosfórico (etch-and-rinse) e auto-condicionantes (de um e dois passos) ao substrato dental, submetido a diferentes condições de irradiação com laser de Er,Cr:YSGG. Amostras de esmalte e dentina foram obtidas do terço médio da face vestibular de 216 incisivos bovinos, divididos aleatoriamente em 18 grupos (n=12), de acordo com o substrato, (esmalte e dentina), sistema adesivo (etch-and-rinse, auto-condicionante de um passo e auto-condicionante de dois passos) e condições de irradiação (sem irradiação ? controle, irradiado com refrigeração ar-água e irradiado sem refrigeração ar-água). Em seguida foi realizada inclusão e polimento, sob refrigeração, com lixas de carbeto de silício de granulação decrescente 180, 320, 400 e 600 (por um minuto para padronização da camada de esfregaço). Para os grupos irradiados com laser de Er,Cr:YSGG (?=2,79 ?m, taxa de repetição de 20 Hz), com densidade de energia de 2,8 J/cm2, 12,5 mJ por pulso, potência média de 0,25W, com a ponta S75 de diâmetro de 750 ?m a 1 mm da superfície do substrato. A condição de refrigeração da irradiação foi realizada com 11 mL/min. Os corpos-de-prova foram confeccionados com a resina composta Filtek Z250, em forma de cone invertido para realização do teste de resistência adesiva. Após 24 h de armazenagem em água destilada a 37ºC, fez-se o ensaio de tração a 0,5 mm/min. Os dados foram comparados estatisticamente pelo método de ANOVA com significância de 5%. Os resultados obtidos mostraram que para o tecido esmalte foi observada diferença estatisticamente significante para os fatores adesivo e condições de irradiação empregadas, sem significância para a interação entre os fatores. A resistência de união do sistema adesivo auto-condicionante de dois passos e do sistema adesivo etch-and-rinse apresentam desempenho semelhante, sendo superiores ao sistema adesivo auto-condicionante de passo único. Ainda para esmalte, o efeito das condições de irradiação mostrou que os grupos sem irradiação com laser de Er,Cr:YSGG apresentaram maior resistência adesiva do que os grupos irradiados com refrigeração e sem refrigeração. Para o substrato dentina, houve diferença estatisticamente significante para os fatores de variação principais: sistemas adesivos, condição de irradiação com laser de Er,Cr:YSGG e para a interação adesivo X condição de irradiação. Quanto à comparação entre os sistemas adesivos testados na condição sem irradiação, os sistemas adesivos auto-condicionantes, de dois passos e o de um passo, não foram estatisticamente diferentes entre si, porém ambos forneceram resultados de resistência adesiva estatisticamente menores do que o sistema adesivo etch-and-rinse. Para as condições de irradiação com laser de Er,Cr:YSGG, com refrigeração e sem refrigeração, obteve-se valores de resistência adesiva maiores para o sistema auto-condicionante de dois passos do que para os demais sistemas. Deste modo, conclui-se que a irradiação com laser de Er,Cr:YSGG reduz a adesão ao esmalte independentemente do sistema adesivo utilizado e da condição de irradiação. Adicionalmente, observa-se que a irradiação de dentina com laser de Er,Cr:YSGG somente não altera a resistência adesiva do sistema auto-condicionante de dois passos, sendo deletéria aos demais adesivos testados. / The aim of this study was to assess the bond strength to dental substrate of adhesives based on previous etching with phosphoric acid (etch-and-rinse) and self-etching (one- and two-step) under different conditions of Er,Cr:YSGG laser irradiation. Enamel and dentin samples were obtained from the middle third of the buccal face of 216 bovine incisors, randomly divided in 18 groups (n=12), according to the substrate (enamel and dentin), adhesive system (etch-and-rinse, one-step self-etching and two-step self-etching) and irradiation condition (without irradiation ? control, irradiated with cooling, and irradiated without cooling). Next, the samples were included and polished, under cooling, with silicone carbide abrasive papers of decreasing grit #180, 320, 400 and 600 (for one minute to standardize the smear layer). For the irradiated groups with Er,Cr:YSGG laser, an energy density of 2.8 J/cm2, 12.5 mJ per pulse, mean power of 0.25W was selected. During laser irradiation, cooling was performed with 11 mL/min. Inverted cone-shaped test specimens were built-up with resin composite Filtek Z250, for performing the bond strength test. After 24 h storage in distilled water at 37ºC, the tensile test was performed at 0.5 mm/min. The results obtained show, for enamel, statistically significant difference for the factors adhesive and irradiation conditions used, without significance for the interaction among the factors. The bond strength of the 2-step self-etching and the etch-and-rinse adhesive system presented similar performance, being superior to that of one-step self-etching system. For enamel, the effect of the irradiation conditions showed that the groups without Er,Cr:YSGG laser irradiation presented higher bond strength than the groups irradiated with and without cooling. For the dentin substrate there was statistically significant difference for the main variation factors: adhesive systems, condition of Er,Cr:YSGG laser irradiation and for the interaction adhesive X irradiation condition. As regards the comparison among the adhesive systems tested under the condition without irradiation, the one-step and two-step self-etching adhesive systems did not differ statistically between them, but both provided statistically lower bond strength results than the etch-and-rinse adhesive system. For the condition of Er,Cr:YSGG laser irradiation with and without cooling, higher bond strength values were obtained for the two-step self-etching system than for the other systems. Therefore, it was concluded that Er,Cr:YSGG laser irradiation reduces the bond strength to enamel irrespective of the adhesive system used and the irradiation condition. Furthermore, it was observed that dentin irradiated with Er,Cr:YSGG laser did not alter the bond strength of the two-step adhesive system only, and it was deleterious to the other adhesives tested.
9

Avaliação da resistência ao desgaste de revestimentos duros aplicados por soldagem em martelos trituradores de baterias automotivas.

SOUSA NETO, Emydio Clemente de. 23 April 2018 (has links)
Submitted by Kilvya Braga (kilvyabraga@hotmail.com) on 2018-04-23T10:51:37Z No. of bitstreams: 1 EMYDIO CLEMENTE DE SOUSA NETO - DISSERTAÇÃO (PPGEM) 2015.pdf: 5264287 bytes, checksum: 48883828373d3daac0f65ee6e1ef7809 (MD5) / Made available in DSpace on 2018-04-23T10:51:37Z (GMT). No. of bitstreams: 1 EMYDIO CLEMENTE DE SOUSA NETO - DISSERTAÇÃO (PPGEM) 2015.pdf: 5264287 bytes, checksum: 48883828373d3daac0f65ee6e1ef7809 (MD5) Previous issue date: 2015-07-31 / O desgaste prematuro de conjuntos e componentes industriais, bem como de uma infinidade de outros segmentos, representa um grande fator para a redução da eficiência operacional de um equipamento, provocando assim, um aumento das perdas, e consequentemente, em altas despesas com manutenção e reposição de componentes mecânicos. Este trabalho aborda uma análise comparativa entre a resistência ao desgaste de martelos trituradores de baterias recuperados por três ligas a base de cobalto (Stellite 1, 6 e 21), bem como dois processos de deposição: os processos ao Arco Elétrico com Eletrodo Revestido (SMAW) e ao Arco Plasma Transferido com adição de Pó (PTA-P). Os martelos trituradores são originalmente confeccionados em aço inoxidável AISI 316 L sem nenhum recobrimento. Além da avaliação da resistência ao desgaste no próprio meio de trabalho foram realizados ensaios de microdureza, análises microestruturais via microscopia ótica, e eletrônica de varredura e, análise de diluição com o objetivo de caracterizar e consolidar a pesquisa para que se tenha o estudo comparativo da melhor liga e melhor processo de deposição. Os resultados demostraram que a melhor condição testada foi aquela que empregou a liga Stellite 6 depositadas pelo processo PTA-P. Essa condição apresentou a menor perda de massa nos ensaios de resistência ao desgaste, enquanto que a condição menos favorável foi verificada para os depósitos executados com a liga Stellite 1 utilizando o mesmo processo de deposição. A diluição média das ligas depositadas pelo processo SMAW foi 3,7 vezes maior do que a média apresentada utilizando o processo PTA-P. Os maiores valores de microdureza foram aqueles apresentados pelo revestimento executados com a liga Stellite 1 com maior teor de C, e esta liga, proporcionou um maior número de destacamento dos revestimentos. A microestrutura dos depósitos executados pelo processo PTA-P apresentou-se mais refinada quando comparada com aquelas depositadas pelo processo SMAW. / The premature wear sets and industrial components, as well as many of other segments, is a big factor for reducing operational efficiency of equipment, thus causing an increase in losses, and consequently in high cost of maintenance and replacement of mechanical components. This work presents a comparative analysis of the wear resistance of AISI 316 L steel automotive batteries crushers hammers repaired by welding process using three cobalt-based alloys: Stellite 1, 6 and 21, as well as, two welding deposition process: Shielded Metal Arc Welding (SMAW) and Plasma Transferred Arc with addition powder (PTA-P). Crushers hammers are originally made of stainless steel AISI 316 L with no coating. Besides the “in situ” wear resistance evaluation microhardness tests, microstructure and dilution analysis by optical microscopy and scanning electron were done to characterize and consolidate research in order to have a comparative study of best league and better deposition process. The results showed that the best alloy was Stellite 6 using the PTA-P process, which had the lowest mass loss in wear resistance tests, while the less favorable condition was for deposits made with the alloy Stellite 1 using the same deposition welding process. The average dilution of the alloys deposited by the SMAW process was 3.7 times higher than the average using the PTA-P process. The highest microhardness values were presented by Stellite 1 alloy deposit, with higher C content, which also provided a greater number of coating detachment. The deposits made by the process PTAP showed a more refined microstructure when compared to those deposited by the SMAW process
10

Estudo em múltiplas frequências da baixa atmosfera solar durante explosões

Huaman, Denis Pavel Cabezas 26 March 2015 (has links)
Made available in DSpace on 2016-03-15T19:35:52Z (GMT). No. of bitstreams: 1 DENIS PAVEL CABEZAS HUAMAN.pdf: 1718725 bytes, checksum: b98f52c6b4dac9b37a33cc5bc62d871e (MD5) Previous issue date: 2015-03-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The project aims to study the disturbances (responses) of the low solar atmosphere caused by solar flares, using Hα, 30 THz (10 μm), UV/EUV, soft and hard X-rays observations, and a wide range of radio waves emissions (microwaves, millimeter, sub-millimeter). This set of multispectral data enabled us to (i) examine in detail various aspects of the phenomena, (ii) determine the origin of the radio emission during the gradual phase, and therefore (iii) understand the mechanism of the particles acceleration. The data we used for the completion of this study are based on Hα and 30 THz (10 μm) observations, made by the high cadence flare imaging system installed at OSM4 and CASLEO5 observatories, additionally data from HASTA (H-Alpha Solar Telescope for Argentina) telescope installed at OAFA6 observatory. In the sub-millimeter and millimeter domain at 212, 405 GHz and 45, 90 GHz, were from SST (Solar Sub-millimeter Telescope) and from POEMAS (POlarization Emission of Millimeter Activity at the Sun) solar radio telescopes, respectively. Complementary radio observations in the microwave range (0.2-15 GHz) from RSTN (Radio Solar Telescope Network) were considered. In addition, solar observations obtained by RHESSI (Reuven Ramaty High Energy Solar Spectroscopic Imager), Fermi and GOES (Geostationary Operational Environmental Satellite) satellites in X-ray channels, and from AIA (Atmospheric Imaging Assembly) and HMI (Helioseismic and Magnetic Imager) instruments, onboard the SDO (Solar Dynamics Observatory) satellite, respectively. / O trabalho tem como objetivo estudar as perturbações da baixa atmosfera solar produzidas pelas explosões solares, usando observações em Hα, 30 THz (10 μm), UV/EUV, raios X e uma ampla faixa de emissões em ondas de rádio (microondas, milimétrica, submilimétrica); com o propósito de determinar a natureza dos processos físicos envolvidos. Este conjunto de dados multiespectrais nos permitiu (i) analisar os diferentes aspectos das explosões tanto na fase impulsiva como gradual, (ii) determinar a origem da emissão em rádio durante a fase gradual, e consequentemente (iii) entender melhor os mecanismos de aceleração das partículas. Os dados em Hα e 30 THz foram fornecidos pelo sistema de aquisição de dados com alta resolução temporal, instalado nos observatórios OSM1 e CASLEO2, adicionalmente dados do telescópio HASTA (H-Alpha Solar Telescope for Argentina) instalado no observatório OAFA3. Enquanto as observações em rádio, os dados foram do rádio polarímetro POEMAS (POlarization Emission of Millimeter Activity at the Sun) nas frequências de 45 e 90 GHz, do telescópio SST (Sub-millimeter Solar Telescope) nas frequências 212 e 405 GHz, ambos instalados no CASLEO. Dados na faixa de microondas (0,2-15 GHz) obtidos pela rede RSTN (Radio Solar Telescope Network). Além disso, foram considerados observações do Sol obtidas pelos satélites RHESSI (Reuven Ramaty High Energy Solar Spectroscopic Imager), Fermi e GOES (Geostationary Operational Environmental Satellite) para raios X, e dos instrumentos AIA (Atmospheric Imaging Assembly), HMI (Helioseismic and Magnetic Imager), a bordo do satélite SDO (Solar Dynamics Observatory), respectivamente.

Page generated in 0.0424 seconds