• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1230
  • 239
  • 59
  • 11
  • 8
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1641
  • 463
  • 391
  • 191
  • 179
  • 160
  • 158
  • 129
  • 129
  • 128
  • 127
  • 112
  • 111
  • 108
  • 106
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Protection des sources d'eau potable : portrait de la contamination de l'eau par Cryptosporidium sp. et Giardia sp.

Fradette, Marie-Stéphanie 16 January 2024 (has links)
Titre de l'écran-titre (visionné le 12 janvier 2024) / Cryptosporidium sp. et Giardia sp., deux protozoaires parasites de l'homme et/ou de l'animal, sont des ennemis tenaces des usines de production d'eau potable partout à travers le monde. En effet, leur forme de dissémination les rend plus aisément dispersibles dans les étendues d'eau et plus robustes faces aux stress environnementaux en attendant leur ingestion par leur prochain hôte. Par ailleurs, cette forme les rend tous deux résistants au chlore, le composé le plus couramment utilisé dans la désinfection chimique de l'eau. D'autres moyens sont disponibles pour les éliminer, mais la performance de ceux-ci dépend de la concentration de parasites dans l'eau brute. Il est donc important de connaître la concentration de ces deux organismes dans les sources d'eau alimentant les usines de production d'eau potable et de cibler les conditions et/ou les moments de l'année durant laquelle chaque source est vulnérable à la contamination par ces agents pathogènes. Les objectifs du présent projet consistaient à 1) développer un outil biomoléculaire de détection spécifique à ces deux micro-organismes, 2) à optimiser le protocole de récupération de ceux-ci à partir d'eau brute, 3) à évaluer leur présence dans trois eaux de source du Québec d'un point de vue temporel ainsi que géographique et finalement, 4) à rechercher des corrélations entre le nombre de parasites et d'autres paramètres environnementaux. En cours de projet, il a été constaté que les méthodes de détection biomoléculaire actuellement disponibles manquent soit de sensibilité, soit de spécificité ou soit de reproductibilité pour être appliquées à la surveillance de Cryptosporidium sp. et de Giardia sp. dans l'eau environnementale. Les techniques de PCR et de LAMP ont été tentées avec plusieurs cibles génétiques différentes ainsi qu'avec différentes amorces sans permettre de trouver un protocole permettant de répondre à ces trois critères. Il a donc été décidé de se tourner vers le seul protocole standardisé actuellement disponible, soit la méthode 1623.1 de l'USEPA. Toutefois, compte tenu de ses pourcentages de récupération globalement faibles, des essais ont été entrepris pour tenter de modifier cette technique dans l'optique d'améliorer sa performance et/ou de diminuer les coûts requis pour son utilisation. Parmi les quatre approches mises à l'épreuve, le protocole original de la méthode 1623.1 a permis d'obtenir la meilleure récupération en ce qui concerne Giardia. Cependant, pour Cryptosporidium, les quatre protocoles testés ne produisaient pas de récupération statistiquement différente les uns des autres. Ultimement, il a été décidé d'utiliser le protocole original de la 1623.1 pour la suite du projet. Ensuite, une campagne d'échantillonnage d'un an a été menée entre mars 2022 et février 2023 au niveau de l'eau brute de trois usines de production d'eau potable du Québec (Québec, Charny et Lévis). Des prélèvements ont été faits de manière mensuelle avec des dates supplémentaires lors des périodes de transition saisonnière. Chaque échantillon était analysé avec la 1623.1 pour déterminer la concentration de parasites dans chacun des échantillons. Au final, un patron annuel a pu être dessiné pour Giardia avec de fortes concentrations durant les périodes froides et de transition saisonnière ainsi que des concentrations statistiquement plus faibles en période chaude. Pour sa part, la concentration de Cryptosporidium était davantage variable selon la saison et la source d'eau. Avec les données de la campagne d'échantillonnage de 2022-2023, des corrélations statistiques ont pu être établies entre la variation de la concentration d'(oo)cystes et celle de plusieurs paramètres environnementaux. Il a été rapidement constaté qu'aucun des paramètres environnementaux testés ne peut servir de proxy universel aux trois sites ni aux trois saisons pour la même source, pas même les micro-organismes indicateurs de pollution fécale conventionnels. Cependant, des corrélations fortes ont pu être trouvées pour chaque parasite à chaque site pour au moins une saison de l'année. Des modèles de régressions linéaires multiples ont également pu être établis pour chaque site et pour chaque parasite. Grâce aux travaux effectués durant ce projet, on peut conclure que chaque source d'eau possède ses caractéristiques et influences propres qui la rendent unique. Ainsi, les tendances observées à une source ne peuvent pas nécessairement être extrapolées aux autres sources, malgré leur proximité géographique. Par ailleurs, chaque année est unique en soi. Il est donc important d'effectuer une surveillance régulière au niveau de chaque source pour rester à l'affût de variations impromptues dans leur concentration. / Cryptosporidium sp. and Giardia sp., two protozoan parasites of humans and/or animals, are tenacious enemies of water treatment plants around the world. They adopt a dissemination conformation making them easily spread through watercourses and tougher against environmental stresses they undergo while waiting to be ingested by their next host. This conformation also makes them more resistant face to chlore-based treatments used as chemical disinfection in water treatment plants. Other means are available to get rid of them in raw water, but the use of these alternative treatments is concentration-dependent. It is therefore necessary to monitor the concentration of these parasites in water sources supplying treatment plants and to determine the conditions and/or the moments of the year where each water source is vulnerable to contamination by these pathogenic agents. The objectives of this project were to 1) develop a biomolecular tool for the detection of Cryptosporidium and Giardia, 2) optimize the protocol for recovery of these parasites from raw water, 3) evaluate the presence of these microorganisms in three water sources of Québec from a geographical and from a temporal angle, 4) seek statistical correlations between the parasite's concentration and other environmental parameters. Throughout the project, it was found that biomolecular methods available lack either sensitivity, specificity, or reproducibility to be applied for the monitoring of Cryptosporidium sp. and Giardia sp. in environmental water samples. PCR and LAMP experiments were performed targeting different genes and using different primers without being able to fulfill these three criteria. It was then decided to use the only standardized protocol available up to today, the USEPA Method 1623.1. However, knowing the low recovery percentages of this technique, tests were performed to try to improve this protocol and/or decrease the costs associated with it for a similar performance. Among the four approaches tests, the original protocol of the 1623.1 gave the highest recoveries of Giardia. On the other hand, the four protocols did not give statistically different recoveries when compared with each other for Cryptosporidium. Therefore, the original protocol of the 1623.1 was selected for the subsequent steps of this project.Afterwards, a sampling campaign of one year was performed between March 2022 and February 2023. Sample sites were three major water treatment plants of Québec (Québec, Charny and Lévis). Samples of raw water from each site were taken on a monthly basis with supplementary dates during transition periods (spring and fall). Each sample was analyzed with the 1623.1 protocol to determine the parasite concentration in each. Throughout this campaign, an annual pattern was found for Giardia with high concentrations during cold and transition months while concentrations were statistically lower during the warm season. Cryptosporidium's concentration had a much more variable behavior depending on the season and on the water source. With the data collected during the sampling campaign of 2022-2023, statistical correlations could be established between the variation in concentration of parasites and the variation of several environmental parameters. No proxy common to all sites and to all seasons could be found for either protozoan, not even the common fecal pollution indicator microorganisms. However, strong statistical correlations were found for each parasite in at least one season of the year. Multiple linear regression models could be made for each site and each parasite. With the work performed during this project, we can reach the conclusion that each water source has its own characteristics and influences which makes it unique. Therefore, patterns observed for a given source cannot necessarily be extrapolated to other sources, despite their geographical proximity. Moreover, each year has its own particularities, So, it is important to monitor regularly each water source and to stay alert face to unexpected variations in the concentration of these two protozoa.
242

Optimisation spatiotemporelle de la surveillance de la dégradation de la qualité de l'eau potable dans les réseaux de distribution

Ardila Jimenez, Andres Felipe 10 May 2024 (has links)
La surveillance de la qualité de l'eau dans les réseaux de distribution est essentielle pour assurer la conformité réglementaire, identifier les problèmes liés à sa dégradation excessive et proposer des approches visant à limiter la présence de contaminants susceptibles d'affecter la santé des citoyens. Cependant, en raison de contraintes budgétaires, technologiques, et de gestion, les responsables de l'eau potable des municipalités ne sont pas en mesure de surveiller l'ensemble du réseau et doivent choisir des points et des moments de surveillance représentatifs pour déterminer la qualité de l'eau. Bien qu'il s'agisse d'un besoin évident et crucial, il n'existe aucune démarche réglementaire appuyée par la science permettant aux responsables de sélectionner des points optimaux de surveillance. La dégradation de la qualité de l'eau varie dans l'espace et dans le temps le long du réseau de distribution en raison de facteurs spécifiques au système, tels que le temps de séjour de l'eau (TDS), le matériau et le diamètre des conduites, les caractéristiques physicochimiques de l'eau, l'utilisation de désinfectants secondaires, etc. Il est donc difficile pour les opérateurs de déterminer où et quand effectuer des contrôles de la qualité de l'eau. L'objectif principal de cette thèse de doctorat est de proposer une nouvelle démarche méthodologique pour optimiser la localisation des points et la fréquence de surveillance dans le réseau de distribution qui tienne compte de la variabilité spatio-temporelle des indicateurs de qualité de l'eau. Cette nouvelle démarche vise à répondre aux besoins méthodologiques identifiés à travers une revue chronologique et critique de la littérature, qui comprend l'identification des concepts fondamentaux, des techniques d'optimisation, ainsi que des avantages et des limites des méthodologies spécifiquement axées sur l'optimisation de la dégradation de la qualité de l'eau dans les réseaux de distribution présentées précédemment par la communauté scientifique. Cette thèse présente une approche innovante basée sur la variabilité spatio-temporelle de la qualité de l'eau, applicable à une échelle réelle par les responsables des municipalités. La méthodologie propose l'identification d'une zone géographique qui peut être représentée par la qualité de l'eau mesurée dans un point de surveillance sélectionné. La démarche fait appel à la connaissance des caractéristiques hydrauliques du réseau (débits et sens d'écoulement) ainsi qu'à celles des conditions associées à une forte variabilité spatiale des indicateurs entre les points qui partagent une connexion hydraulique. Compte tenu de l'utilisation du modèle hydraulique, les nœuds du modèle sont considérés comme des points de surveillance potentiels dans le réseau de distribution, ce qui permet de parler de nœuds de surveillance et nœuds de surveillance optimaux. Ensuite, la population représentée par chaque nœud du réseau est estimée et utilisée dans l'optimisation de la sélection des points de surveillance. Une évaluation est effectuée sur la base du nombre d'individus que chaque nœud peut représenter et le nœud ayant la plus grande capacité de représentation est choisi. Lorsqu'un nœud est choisi, la population représentée par ce nœud est considérée comme surveillée et le meilleur nœud suivant est sélectionné. Cette procédure est répétée jusqu'à ce que l'ensemble de la population cible soit considérée comme surveillée. La démarche proposée est appliquée au réseau de distribution de la Ville de Québec (Québec, Canada) afin d'optimiser la surveillance de quatre indicateurs de la qualité de l'eau: le chlore libre résiduel (CLR), les bactéries hétérotrophes totales aérobies et anaérobies (BHAA), les trihalométhanes (THM) et les acides haloacétiques (AHA). Deux objectifs d'optimisation sont pris en compte: l'optimisation de la représentativité de la population globale et la surveillance de la population à risque en raison d'une forte dégradation de la qualité de l'eau. Les résultats montrent que la variabilité spatiale de l'indicateur de la qualité de l'eau a une forte influence sur la représentativité des nœuds, ce qui fait que les indicateurs à forte variabilité spatiale, tels que le CLR, nécessitent un grand nombre de points de surveillance pour représenter l'ensemble de la population cible. Malgré cela, la méthodologie permet d'identifier les nœuds ayant une forte capacité de représentativité. Ces nœuds devraient être priorisés parce qu'ils maximisent la population représentée en minimisant les points de surveillance sélectionnés. De même, les résultats montrent que la surveillance de tous les indicateurs dans le même point n'est pas pertinente, car les conditions de variabilité spatiale sont propres à chaque indicateur. Ces conditions déterminent le nombre et la localisation optimaux des points de surveillance pour chaque indicateur individuellement. L'impact du comportement hydraulique et de l'incertitude liée à la modélisation a été analysé en appliquant la démarche proposée pour différents scénarios. Pour ce faire, des scénarios temporels de surveillance intra-journalière, journalière et saisonnière ont été étudiés et comparés. Les résultats obtenus pour l'étude de cas considérée montrent qu'à l'échelle intra-journalière, la localisation des points de surveillance ne varie pas de manière significative étant donné que le comportement hydraulique global du réseau n'est pas affecté. Le même effet peut être observé en comparant un jour de forte demande en eau (débit journalier maximum) à un jour de consommation moyenne (débit journalier moyen). Cependant, l'échelle de temps saisonnière joue un rôle dans la détermination des points de surveillance optimaux. En effet, en raison de la plus faible variabilité spatiale des indicateurs de la qualité de l'eau en hiver, moins de mesures sont nécessaires pour surveiller la même proportion de la population qu'en été. En revanche, la localisation spatiale des nœuds ayant une capacité de représentativité plus élevée ne semble pas changer d'une saison à l'autre, ce qui permet d'identifier des points de surveillance optimaux tout au long de l'année. La démarche proposée est un outil innovant d'aide à la décision pour la sélection optimale des points de surveillance de la qualité de l'eau des réseaux de distribution. Cette méthodologie est originale par la prise en compte de la variabilité spatio-temporelle de la qualité de l'eau, ainsi que par son adaptabilité pour l'optimisation de la surveillance de tout type d'indicateur pour lequel des conditions de forte variabilité spatiale peuvent être définies. / Monitoring water quality in distribution networks is essential to ensure regulatory compliance, identify problems associated with excessive degradation, and propose approaches to limit the presence of contaminants that could jeopardize citizens' health. However, due to budgetary, technological and management constraints, municipal drinking water authorities are unable to monitor the entire network, and must select representative monitoring points and times to determine water quality levels. Although this is an obvious and crucial need, there is no science-based regulatory approach to enable managers to select appropriate monitoring points. Furthermore, water quality degradation varies spatially and temporally along the distribution network, due to system-specific factors such as water residence time (WRT), pipe material and diameter, physicochemical characteristics of the water, use of secondary disinfectants, etc. This makes it all the more difficult for operators to determine where and when to carry out water quality checks. The main objective of this PhD thesis is to propose a new methodological approach for optimizing the location of monitoring points and the frequency of monitoring in the distribution network, taking into account the spatio-temporal variability of water quality indicators. This new approach aims to meet the methodological needs identified through a chronological and critical review of the literature, which includes the identification of fundamental concepts, optimization techniques, as well as the advantages and limitations of methodologies previously presented by the scientific community. This thesis presents an innovative approach based on the spatio-temporal variability of water quality, which can be applied on a real scale by municipal managers. The methodology proposes the identification of a geographical area that can be represented by the measured water quality of a selected monitoring point. The approach calls on knowledge of the network's hydraulic characteristics (flow rates and direction of flow), as well as of the conditions associated with high spatial variability of indicators between points sharing a hydraulic connection. Given the use of the hydraulic model, the nodes in the model are considered as potential monitoring points in the distribution network, hence the term monitoring nodes and optimal monitoring nodes. Next, the population represented by each network node is estimated and used to optimize the selection of monitoring points. An evaluation is made based on the number of individuals each node can represent, and the node with the greatest representation capacity is chosen. Once a node has been chosen, the population represented by that node is considered as monitored, and the next best node is selected. This procedure is repeated until the entire target population is considered monitored. The proposed approach is applied to the distribution network of Quebec City (Quebec, Canada) to optimize the monitoring of four water quality indicators: free chlorine residual (FRC), heterotrophic plate counts (HPC), trithalomethanes (THM) and haloacetic acids (HAA). Two distinct optimization objectives are taken into account: optimizing the global representativeness of the population and monitoring the population at risk due to high water quality degradation. The results show that the specific spatial variability of the water quality indicator has a strong influence on the representativeness of the nodes, meaning that indicators with high spatial variability, such as FRC, require a large number of monitoring points to represent the entire target population. Despite this, the methodology enables us to identify nodes with a high representativeness capacity. These nodes should be prioritized as they maximize the population represented reducing the monitoring points needed. Similarly, the results show that monitoring all indicators as a whole at the same point is not relevant, as the conditions of spatial variability are specific to each indicator; these conditions determine the optimal number and location of monitoring points for each indicator individually. The impact of hydraulic behavior and modeling uncertainty was analyzed by applying the proposed approach to different temporal scenarios. Intraday, daily and seasonal monitoring scenarios were studied and compared. The results obtained for the case study under consideration show that on an intraday scale, the location of monitoring points does not vary significantly, as the overall hydraulic behavior of the network is not affected. The same effect can be observed when comparing a day of high water demand (maximum daily flow) with a day of average consumption (average daily flow). Finally, the seasonal timescale plays an important role in determining optimum monitoring points. Indeed, due to the lower spatial variability of water quality indicators in winter, fewer measurements are required to monitor the same proportion of the population as in summer. On the other hand, the spatial location of nodes with a higher representativeness capacity does not appear to change from one season to the next, enabling optimal monitoring points to be identified throughout the year. Finally, the proposed approach will serve as an innovative decision-making tool for the optimal selection of water quality monitoring points in distribution networks. The methodology is original in that it takes into account the spatio-temporal variability of water quality, and is adaptable to optimize the monitoring of any type of inditor for which conditions of high spatial variability can be defined.
243

Variation des sous-produits de la désinfection de l'eau potable au point d'utilisation résidentiel

Dion-Fortier, Annick 13 April 2018 (has links)
Tableau d’honneur de la Faculté des études supérieures et postdoctorales, 2008-2009 / La population n'est pas nécessairement exposée à l'eau potable du réseau de distribution. En effet, l'eau peut stagner dans la tuyauterie résidentielle ou séjourner dans le réservoir d'eau chaude pendant plusieurs heures avant d'être consommée. La qualité de l'eau en est affectée et en particulier les sous-produits de la désinfection (SPD). La présente étude a démontré que les concentrations moyennes de trihalométhanes (THM) augmentent lorsque l'eau froide stagne dans les conduites résidentielles et de façon plus importante lorsque l'eau séjourne dans les réservoirs d'eau chaude. Les concentrations d'acides haloacétiques (AHA) augmentent également dans les deux cas mais de manière moins importante que celles des THM. L'hiver et l'automne sont les saisons où les concentrations de ces composés augmentent le plus par rapport à celles retrouvées dans l'eau du réseau de distribution. L'étude a aussi démontré que, autant dans les conduites que dans les réservoirs d'eau chaude résidentiels, les espèces chlorées et bromées ne se comportent pas de la même manière. Finalement, les résultats de l'étude montrent qu'une utilisation soutenue de l'eau à la maison permet de garder les niveaux de THM et d'AHA près de ceux retrouvés dans l'eau du système de distribution.
244

Occurrence de sous-produits émergents dans l'eau potable ozonée : cas des acétaldéhydes halogénés

Gao, Jianan 11 March 2021 (has links)
La désinfection de l'eau potable par le chlore permet d'inactiver les micro-organismes pathogènes et de contrôler la croissance microbienne au cours du transport de l'eau dans le réseau de distribution municipal. En présence de la matière organique et inorganique dans l'eau brute, ce procédé de traitement conduit à la formation de sous-produits de la désinfection (SPD) incluant les trihalométhanes (THM) et les acides haloacétiques (AHA) qui sont réglementés. Afin de respecter les normes pour ces SPD formés au cours de la chloration, les rayons ultraviolets et d'autres oxydants tels que l'ozone, le dioxyde de chlore ou la chloramine peuvent être utilisés comme désinfectants alternatifs pour la désinfection primaire. L'ozonation est communément appliquée durant la production d'eau potable non seulement pour permettre la diminution de la teneur en SPD réglementés mais aussi en raison de sa puissance comme désinfectant et oxydant. Néanmoins, compte tenu de courte demi-vie de l'ozone dans l'eau (l'ozone n'a pas d'effet rémanent), son utilisation requiert l'application de chlore ou de chloramine suivant l'ozonation afin de s'assurer la sécurité de l'eau distribuée. Toutefois, ce scénario de désinfection de l'eau potable (ozone-chlore/chloramine) favorise la formation des acétaldéhydes halogénés (halogenated acetaldehydes, HAL). Ces derniers attirent de plus en plus d'attention dans les dernières années en raison de leur abondance (troisième plus grande famille de SPD) et de leur cytotoxicité élevée. La présente thèse s'est donc consacrée à améliorer les connaissances sur la présence et la variabilité spatio-temporelle des HAL dans les réseaux d'aqueduc ainsi que sur les niveaux d'exposition de la population à ces contaminants dans les eaux potables désinfectées à l'ozone. Dans un premier temps, différents paramètres (pH, agent de conservation et durée de conservation) ont été optimisés pour la conservation des échantillons afin d'analyser les acétaldéhydes trihalogénés (trihalogenated acetaldehydes, THAL) et acétaldéhydes dihalogénés (dihalogenated acetaldehydes, DHAL) par une méthode analytique consolidée qui a été validée en laboratoire. Par la suite, quatre campagnes d'échantillonnage ont été réalisées sur deux ans (entre 2017 et 2019) au sein de deux systèmes d'eau potable sélectionnés comme cas à l'étude. La première campagne d'échantillonnage s'est échelonnée sur une année et a généré une base de données robuste sur le comportement de HAL dans les usines de traitement d'eau potable (UTEP) et leur variabilité spatio-temporelle dans les réseaux de distribution. À la suite de cette campagne, la relation entre l'ozonation et la variation de HAL dans l'eau traitée a été évaluée pendant un mois via une campagne d'échantillonnage intensive, dans une UTEP où les changements de pratique de l'ozonation avaient lieu. Finalement, deux autres campagnes d'échantillonnage ont été effectuées pour évaluer les effets de manipulations domestiques de l'eau sur la concentration de HAL à laquelle la population est exposée. Les résultats obtenus ont permis d'identifier les facteurs contribuant à la formation de HAL dans l'eau potable et de déterminer les stratégies de manipulation domestique pour réduire l'exposition aux HAL via l'eau potable. En se basant sur les concentrations de THM, la prédiction de la concentration de THAL est devenue possible grâce aux fortes corrélations entre les concentrations de THM et de THAL dans les deux systèmes d'eau potable à l'étude. / Disinfection of drinking water with chlorine results in the inactivation of targeted pathogens and the control of microbial growth during the transportation through the distribution system, while in the presence of naturally occurring organic and inorganic matter, disinfection by-products (DBPs) are formed. For instance, trihalomethanes (THMs) and haloacetic acids (HAAs) are regulated in many countries. In order to meet the regulations, ultraviolet irradiation and other oxidants such as ozone, chlorine dioxide or chloramines are used as alternative disinfectants for primary disinfection. Ozonation is commonly applied during water treatment not only due to the intended reduction in the levels of regulated THMs and HAAs but also its numerous advantages as oxidant and disinfectant. However, the use of chlorine or chloramines following ozonation is generally required to ensure the safety of drinking water in distribution systems due to the short half-life of ozone. Unfortunately, this disinfection scenario (ozone-chlorine/chloramines) promotes the formation of halogenated acetaldehydes (HALs), which attract more and more attention in the last years due to their abundance in drinking water (third largest group of identified DBPs by weight) and their relatively high cytotoxicity. This thesis is therefore devoted to improving the knowledge about the occurrence and spatio-temporal variability of HALs as well as the levels of human exposure to these contaminants in ozonated drinking water. First, various parameters (pH, quenching agent and sample holding limit) were optimized for sample preservation in order to analyze trihalogenated acetaldehydes (THALs) and dihalogenated acetaldehydes (DHALs) using a consolidated analytical method. Subsequently, four sampling campaigns were conducted over two years (between 2017 and 2019) in two drinking water systems. The first one-year sampling campaign generated a robust database of HALs regarding their behavior in drinking water treatment plants (DWTPs) and the spatio-temporal variability in distribution networks. Then the relationship between ozonation and HAL variation in treated water was assessed during a one-month intensive sampling campaign, in a DWTP where changes regarding ozonation procedures occurred. Finally, two more sampling campaigns were carried out to evaluate the effects of household tap water handling on the exposure of HALs. The results allow to identify the contributing factors to HAL formation in drinking water and to determine strategies of household handling for the control of HAL exposure via drinking water. The prediction of the occurrence of THALs based on THMs was made possible because of the strong correlations between THM levels and THAL levels in both drinking water systems.
245

Les Problèmes de l'eau dans une ville moyenne, cas de la ville de Millau, Aveyron : approvisionnement en eau, impact des rejets industriels (industrie des cuirs et peaux) et urbains sur le Tarn.

Bénézet, Jean-Pierre, January 1900 (has links)
Th. 3e cycle--Pharm. métrol. des polluants dans l'alimentation et l'environnement--Montpellier 1, 1979.
246

Drinking water quality and management strategies in small Quebec utilities

Coulibaly, Housseini Diadié 11 April 2018 (has links)
La présente thèse porte sur une étude des petits systèmes municipaux du Québec (en l’occurrence, ceux desservant 10 000 personnes ou moins) et comporte trois volets. Le premier volet se focalise sur un portrait historique de la qualité de l’eau distribuée et sur les stratégies de gestion. Parallèlement, il met l'historique de la qualité et les stratégies de gestion en relation avec certains paramètres importants de la qualité de l’eau. Les résultats de ce volet montrent que pour les systèmes s’approvisionnant en eau de surface et pratiquant uniquement une chloration, la différence entre le nombre annuel moyen de rinçages des systèmes ayant connu des problèmes de qualité et ceux n’ayant pas connu de tels problèmes s’est avérée statistiquement significative. En plus, certains indicateurs de la pression agricole sur le territoire des municipalités concernées apparurent significativement corrélés avec les épisodes de coliformes. Le deuxième volet porte sur une étude de la variation spatio-temporelle de la qualité de l’eau dans dix petits systèmes. Ces systèmes furent répartis en deux groupes : quatre systèmes qui n’ont jamais ou ont rarement distribué de l’eau dérogeant aux normes microbiologiques provinciales relatives à l’eau potable et six systèmes qui ont très souvent dérogé auxdites normes. Les résultats montrent que les différences entre les deux groupes de systèmes sont essentiellement imputables aux teneurs en chlore résiduel libre et au nombre de colonies de bactéries hétérotrophes aérobies et anaérobies facultatives (BHAA) dans les réseaux de distribution correspondants et, dans une moindre mesure, aux doses de chlore appliquées. Le troisième volet inclut trois parties : la première est un portait des caractéristiques d’opération, de l’infrastructure et de la maintenance ; la deuxième est consacrée au développement d’indicateurs de performance pour les petits systèmes ; alors que la troisième traite des facteurs humains et organisationnels. Le portrait a révélé des tendances intéressantes qui ont presque toutes été confirmées par les indicateurs de performance des systèmes de distribution. Les facteurs humains et organisationnels dégagèrent des aspects tels que les antécédents scolaires, la formation complémentaire, l’expérience, la bonne conscience des nouveaux défis, le niveau de préparation pour y faire face, et l’appui des autorités locales. Dans son ensemble, cette recherche aura permis de procéder à une étude exhaustive des stratégies de gestion de la qualité de l’eau potable généralement mises de l’avant par les gestionnaires de petits systèmes et de développer des outils explicatifs pouvant guider utilement leur action, de même que celle des gestionnaires relevant des divers paliers gouvernementaux. / This thesis presents a study of small Quebec municipal utilities (i.e., serving 10,000 people or fewer) and includes three chapters. The first chapter focuses on a portrait of historical quality of distributed water and on management strategies. Concurrently, it puts historical quality and management strategies in relation to certain important water quality parameters. Results show that for surface water utilities using chlorination alone, the mean difference of annual system flushings between utilities that have experienced difficulties with historical quality and those not having experienced such difficulties proved statistically significant. In addition, some agricultural land-use indicators within the municipal territory appeared significantly correlated with coliform occurrences. The second chapter studies the spatial and temporal variation of drinking water quality in ten small utilities. These utilities were divided into two groups: four utilities that had never or rarely served water violating the provincial drinking water microbiological standards and six utilities that very often infringed upon said standards. Results show that the differences between the two groups of utilities are associated essentially with maintained chlorine residuals and heterotrophic plate count bacteria populations in corresponding distribution systems and, to a lesser extent, to the applied chlorine doses. The study includes three distinctive parts: the first one is a portrait of studied utilities’ operational, infrastructure, and maintenance characteristics; the second part is devoted to development of indicators of performance for the same utilities, whereas the last part deals with human and organisational factors. The portrait revealed interesting trends, most of which had been confirmed by utility performance indicators. As for human and organizational factors, they allowed highlighting such issues like educational background, supplementary training, experience, awareness of and preparedness to take up new challenges, and support from local authorities. Overall, this research enabled a thorough investigation of management strategies the most popular with small drinking water utilities and the development of explanatory tools that may usefully guide action from local managers and government bodies.
247

Variabilité spatio-temporelle des sous-produits de la désinfection émergents (haloacétonitriles, halonitrométhane et halocétones) dans un réseau de distribution d'eau potable

Mercier Shanks, Catherine 18 April 2018 (has links)
Outre les trihalométhanes (THM) et les acides haloacétiques (AHA), d'autres sous-produits de la désinfection, dits émergents (SPDE), sont présents à de plus faibles concentrations dans l'eau potable. Certains d'entre eux présentent un risque potentiel pour la santé humaine supérieur à celui des THM et des AHA. Sept de ces SPDE méritent une attention particulière : quatre haloacétonitriles, un halonitrométhane et deux halocétones. Au cours de cette étude, la variabilité spatio-temporelle des concentrations de ces SPDE a été évaluée dans un réseau de distribution d'eau potable par le biais de campagnes de prélèvements mensuelles effectuées pendant une année à dix endroits répartis le long du principal réseau de la Ville de Québec. Les SPDE visés ont été observés à des concentrations d'au plus 6 ug/L. Les résultats montrent que les concentrations des SPDE étudiés varient de manière significative selon les saisons et selon le temps de séjour de l'eau dans le réseau.
248

Étude d'un système de trigénération décentralisé en climats canadiens

Allaire Tanguay, Dominique January 2011 (has links)
Ce mémoire présente l'étude d'un système de trigénération ou CCHP (combined cooling, heating and power) au gaz naturel fournissant les besoins thermiques à un immeuble à logement typique de 13 étages. Un groupe électrogène permettant de générer de l'électricité tout en fournissant de l'eau chaude assure le chauffage du bâtiment et de l'eau chaude sanitaire tandis qu'une machine à absorption ammoniac-eau permet de transformer cette chaleur en puissance frigorifique afin de climatiser le bâtiment en période chaude. Le modèle de cette machine à absorption a spécialement été conçu pour fonctionner avec une température de désorption basse et permet d'évaluer les performances de telles machines dans des situations hors design. Ce modèle a été vérifié à l'aide d'autres modèles avérés et propose des coefficients de performance de l'ordre de 0,7 à 0,8. L'évaluation des performances horaires de ce système est présentée pour une année standard sous trois climats canadiens. Ces performances sont ensuite comparées aux différentes méthodes employées pour assurer ces besoins ainsi que pour générer l'électricité supplémentaire. Les résultats démontrent d'excellentes performances même lorsque comparées aux plus récentes technologies. Les résultats passent d'une légère augmentation de la consommation de gaz naturel dans un climat chaud comme Toronto à une importante réduction dans un climat froid comme Edmonton. Ce système permet donc de combler les besoins thermiques d'un bâtiment tout en générant de l'électricité dans des périodes de pointes annuelles et possiblement journalières. Plusieurs études dont notamment l'optimisation du système et le couplage à d'autres types de bâtiment permettrait cependant de mieux évaluer les possibilités complètes de la trigénération.
249

Acquisition de la maladie du légionnaire suite à une exposition domestique

Duchesne, Annie January 2004 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
250

Caractérisation des pathotypes d'Escherichia coli dans les eaux des Grands Lacs à l'aide d'une biopuce d'ADN

Hamelin, Katia January 2006 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Page generated in 0.3511 seconds