• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 930
  • 14
  • 12
  • 12
  • 12
  • 11
  • 8
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 973
  • 347
  • 300
  • 237
  • 208
  • 203
  • 201
  • 199
  • 180
  • 161
  • 155
  • 127
  • 116
  • 108
  • 104
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
401

Bases conceituais da implantação de redes elétricas inteligentes de distribuição de energia elétrica. / Conceptual basis for implementation of distribution smart grids.

Antonio Paulo da Cunha 18 May 2011 (has links)
As redes elétricas inteligentes significam um novo paradigma de fornecimento de energia, cuja concepção integra várias áreas de concentração, novas funcionalidades e funções até então não realizáveis, bem como uma pluralidade de tecnologias e a necessidade de infraestrutura de apoio para a sua realização. A transição das redes elétricas atuais para o modelo de rede inteligente constitui-se num processo complexo, que envolve aspectos técnicos, econômicos, regulatórios e sociológicos. Esta pesquisa visa contribuir significativamente para a solução dessa questão pela proposição das bases conceituais para realizar efetivamente um plano de implementação, respeitando condições vigentes e impostas por cenários de outros setores. O modelo proposto, centrado na expansão da automação, lança as bases para a análise dos impactos da rede elétrica inteligente, para a formulação, análise e seleção de alternativas de implementação. É introduzido o conceito e forma de avaliação de uma rede por meio da definição de um índice de inteligência de uma rede elétrica, composto de vários indicadores, de forma a expressar padrões de eficiência energética e operativa, aspectos de gestão de ativos e da qualidade do serviço. A proposta de alternativas para evolução da automação se baseia em um conjunto de funções pré-estabelecidas, que melhoram os indicadores de desempenho e apresentam custos e benefícios quantificáveis. / The smart grids mean a new paragon for energy supply, whose concept integrates several areas of concentration, functionalities and functions non achievable up to now, as well as a plurality of technologies and the need of supporting infrastructure for its accomplishment. The transition of the present electrical networks to the smart grid model constitutes a complex process, which involves technical, economical, regulatory and sociological aspects. This research aims to contribute significantly to the solution of this issue by proposing the conceptual basis for effectively perform an implementation plan taking into account the constraints imposed by scenarios from other sectors. The proposed model, focused in automation expansion, launches the basis for the impact analysis of Smart Grid in order to formulate, analyze and selection alternatives of implementation. The concept and evaluation method of grid through the definition of a grid intelligence index, composed by several indicators is introduced in order to express standards of energy and operational efficiency, asset management and quality of supply. The proposal of alternatives for automation evolution is based on a set of pre established functions, which improve the performance indicators and present valuable costs and benefits.
402

Análise da variação da tensão gerada e do estado de magnetização em um gerador com ímãs permanentes. / Generated voltage variation and permanent magnet magnetic condition analysis.

André Camargo Mathiazzi 10 August 2007 (has links)
Visando analisar o comportamento de um gerador de ímãs permanentes a partir de diferentes pontos de carga aplicada, quantificando a magnetização dos ímãs presentes, desenvolveu-se um protótipo com desenho propício à adaptação para geradores eólicos. Como o objetivo é a obtenção do comportamento da magnetização dos ímãs permanentes com vários pontos de carga acoplada, optou-se pela utilização de ímãs de ferrite, com valor médio da densidade de fluxo magnético remanente (Br) igual a 0,39 T. Desta forma, o valor da carga acoplada não necessita atingir valores elevados para verificação da variação do comportamento da tensão após aplicação de carga, facilitando a avaliação de possível desmagnetização parcial ou total dos ímãs instalados. Adicionalmente é estudada divisão de carga do gerador, com tensão de saída retificada, operando em paralelo com um barramento C.C. ou banco de baterias. É apresentada uma abordagem analítica de estudo da desmagnetização dos ímãs permanentes do gerador, bem como um levantamento experimental do mesmo. Conduta semelhante é adotada no estudo da divisão de carga. / Aiming to analyze the performance of a permanent magnet generator, operating under variable load and quantifying the corresponding condition of its magnets, we have developed a prototype adaptable to wind generators. As one of the purposes of this work is to study the magnetic performance of the permanent magnets in several points of load, we have chosen ferrite magnets with average remanence (Br) of 0.39 T. Thus, even light variations in load are enough to verify the variation of the generated voltage, which eases the rating of total or partial demagnetization of the installed magnets. Additionally, we study load share of that generator, with rectified output, operating in parallel with D.C. bus or battery bank. An analytic approach of demagnetization of the generator\'s permanent magnets is also presented, as well as an experimental survey of it. A similar procedure is adopted in the study of the load share.
403

Desenvolvimento de uma plataforma digital para a minimização da vibração e da ondulação de torque de um motor de relutância chaveado. / Development of a digital test setup for minimizing the torque ripple and the vibration of a swiched reluctance motor.

Daniel Augusto Prudente Corrêa 14 August 2009 (has links)
A finalidade inicial deste estudo é desenvolver uma metodologia de análise da ondulação de torque de um motor de relutância chaveado especial bifásico com 4 pólos no estator e 2 no rotor (MRC 4/2) através de dados experimentais de aceleração. De forma a validar o método proposto, são apresentados resultados experimentais de aceleração obtidos com dois rotores: o rotor de referência e o rotor otimizado. Uma vez alcançados os objetivos de otimização do torque através da modificação da geometria do rotor, implementou-se um estudo complementar de modo a explorar a vibração e a ondulação de torque, do ponto de vista do acionamento. Desta forma, desenvolveu-se uma plataforma digital de testes, onde os dados de aceleração podem ser monitorados no domínio da frequência, e os parâmetros de controle do acionamento, tais como, a velocidade, os ângulos de ligamento e condução são flexíveis e podem ser alterados através de programa. A plataforma digital foi concebida a partir de um kit de desenvolvimento (eZdsp LF2407A) associado a uma interface de controle serial, desenvolvida a partir de um aplicativo LabView, instalado num microcomputador. / The initial purpose of this study is to develop a methodology of analysis of the torque ripple of a two-phase special SRM 4/2 using acceleration experimental data. In order to validate the proposed method, acceleration experimental results are presented, these results were obtained with two rotors: the reference rotor and the optimized rotor. Once the torque optimization objectives were reached by modifying the rotor geometry, a complementary study from the point of view of motor drive vibration and torque ripple optimization was carried out. Thus, a test digital setup was developed, where the acceleration data could be monitored, in the frequency domain, and the drive control parameters, such as speed, turn-on and dwell angles, and phase current were flexible and could be altered by program. The test digital setup was conceived using a development kit (eZdsp LF2407A) associated with a serial control interface developed on a LabView application, installed in a microcomputer.
404

Alocação ótima de compensação de potência reativa

Stypulkowski, Yuri Solis January 2017 (has links)
Este trabalho propõe uma metodologia para enumerar soluções, que indiquem a barra e a compensação de potência reativa necessária para o sistema elétrico sob análise, que atendam aos requisitos avaliados pela função objetivo e as restrições. Nessa alocação de compensação ótima de potência reativa, obtemos as melhores barras e configurações de potências e tecnologias de dispositivos de compensação, minimizando as perdas totais de potência ativa da rede. Em redes fracas com conversores de frequência (por exemplo, para conexão de fontes renováveis, ou interligações utilizando conversores HVDC), esta metodologia proposta busca a melhor relação de curto-circuito trifásico (SCR) no ponto de conexão do conversor de frequência, melhorando a conexão da barra de interesse. O método busca soluções para alocar um único dispositivo de compensação, e soluções alocando simultaneamente dois dispositivos. A metodologia proposta baseia-se na enumeração exaustiva das soluções, e o estudo de caso nos sistemas de 14 e 30 barras do IEEE mostrou a aplicabilidade e funcionalidade da metodologia proposta. / This work proposes a methodology to enumerate solutions, which indicate the bar and the reactive power compensation required for the electrical system under analysis, that meet the requirements evaluated by the objective function and the constraints. In this allocation of optimal compensation of reactive power, we obtain the optimal bars and technologies of compensation devices, minimizing the total losses of active power of the network. In weak networks with frequency converters (e.g. for connection of renewable sources, or interconnections using HVDC converters), the proposed methodology seeks the best threephase short-circuit (SCR) relation at the connection point, improving the connection of the new generation. The method looks for solutions to allocate a single compensation device, and solutions to allocate two devices simultaneously. The proposed methodology is based on the exhaustive enumeration of the solutions. A case study carried out in the IEEE 14 and 30 bus systems shows the applicability and performance of the proposed methodology.
405

Desenvolvimento de um simulador de redes elétricas para estudos da propagação de harmônicos

LIMA, Diorge de Souza 23 August 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-01-04T13:44:49Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolviementoSimuladorRedes.pdf: 3993762 bytes, checksum: d833db03c025ab4cf9cb2cc2e7498a7e (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-10T17:41:03Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolviementoSimuladorRedes.pdf: 3993762 bytes, checksum: d833db03c025ab4cf9cb2cc2e7498a7e (MD5) / Made available in DSpace on 2017-01-10T17:41:03Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolviementoSimuladorRedes.pdf: 3993762 bytes, checksum: d833db03c025ab4cf9cb2cc2e7498a7e (MD5) Previous issue date: 2016-08-23 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O setor elétrico brasileiro tem enfrentado grandes mudanças devido a modernização dos equipamentos elétricos, principalmente quando se refere aos consumidores residenciais. Isso tem proporcionado um aumento considerável do nível de distorção de harmônicos nas redes elétricas de distribuição, o que pode ser justificado pelo uso acentuado de equipamentos baseados na eletrônica de potência, na tentativa de torná-los cada vez mais eficientes e compactos. Portanto, torna-se necessário a realização de diagnóstico quanto aos níveis de distorções harmônicas em sistemas elétricos. O monitoramento por analisadores de energia é a melhor forma de obter os dados do sistema elétrico, entretanto a simulação computacional é uma eficiente ferramenta capaz de reproduzir os distúrbios e o comportamento da rede elétrica para diferentes modos de operação. Logo, este trabalho tem como objetivo apresentar um ambiente computacional que auxilie nos estudos de propagação de harmônicos nos sistemas elétricos. Para isso, utilizou-se o software ATP (Alternative Transient Program) para a modelagem do sistema elétrico, o comportamento harmônico de uma carga não linear é representado por valores eficazes de medidas de correntes harmônicas em função do tempo. As medidas foram obtidas por meio de analisares de qualidade da energia conectados em uma rede de distribuição da região norte do Brasil. Logo, para esse conjunto de medidas, foi realizado um conjunto de simulações, disponibilizando ao usuário valores de tensões harmônicas para todos os barramentos do sistema elétrico. Portanto, com o simulador de redes elétricas será possível realizar estudos de propagação de harmônicos em diversos sistemas elétricos, podendo auxiliar como uma ferramenta de planejamento estratégico quanto ao uso de medidas mitigadoras ou mesmo para o controle estratégico das distorções harmônicas, a partir das avaliações dos principais momentos críticos de distorções harmônicas em todos os pontos da rede elétrica. Para demonstrar a utilização, o sistema industrial de 13 barras foi utilizado como um sistema teste para as análises nesta dissertação. / The electricity sector in Brazil has faced many changes due to the modernization of electrical equipment, especially when it refers to residential consumers. This has provided a considerable increase in the level of harmonic distortion in the electric distribution networks, which can be explained by the large use of devices based on power electronics in an attempt to make them more efficient and compact. Therefore, it becomes necessary execute analysis of the levels of harmonic distortion in the power systems. Monitoring by power quality analyzer is the best way to collect data of the electrical system; however, the computer simulation is an efficient tool capable of reproducing the disturbances and behavior of the electric networks for different operating modes. Thus, this paper aims to present a computational environment that helps the harmonic propagation studies in electrical systems. For this, it was used the software ATP (Alternative Transient Program) for modeling the electrical system, the harmonic behavior of a nonlinear load is represented by effective values of harmonic currents in function of time. The measurements were obtained through power quality analysis of a distribution network in the North Region of Brazil. Thus, for this set of measures, a set of simulations was performed, providing for the users the values of harmonic voltages for all buses of the electrical system. Therefore, with the simulator of electrical networks it is possible perform harmonic propagation studies in several electrical systems, and it can work as a strategic planning tool for the use of mitigating measures or for the strategic control of harmonic distortion, from evaluations of most critical moments of harmonic distortion at all points of the network. To demonstrate its use, the industrial system of 13 bar was used as a test system for analysis in this dissertation.
406

Estudo da topologia de motores de fluxo axial de excitação híbrida com foco na utilização em tração elétrica. / Study of hybrid excitation axial flux motor topology for electric traction utilization.

Pelizari, Ademir 07 December 2015 (has links)
Os motores de corrente contínua convencionais são muito bem conhecidos pela sua robustez e pelo seu alto nível de controlabilidade, alem do fato de possibilitarem a operação na região de enfraquecimento de campo (modo motor), quando esta situação se fizer necessária. Por estas características, as máquinas de corrente contínua ainda são empregadas nos dias atuais em nichos específicos de utilização. Não obstante, a máquina c.c. apresenta algumas desvantagens, principalmente a intensiva e dispendiosa manutenção eletromecânica necessária para sua operação. Como opção de sanar este problema, surgiram na década de 60, as máquinas elétricas de corrente contínua sem escovas (brushless) com excitação por ímãs permanentes de fluxo trapezoidal. O problema destas máquinas se deve justamente a impossibilidade da variação de fluxo de excitação uma vez que são produzidos puramente pelos ímãs. Sendo assim, este trabalho tem como propósito, o estudo de topologias diferenciadas da máquina elétrica, através de um circuito magnético não convencional para aplicação e utilização em sistemas de tração elétrica para operação na região de enfraquecimento de campo através da variação do fluxo resultante no entreferro. Como objeto de estudo, foi focada a topologia de fluxo axial com excitação híbrida, ou seja, dupla excitação (excitação a ímãs permanentes e excitação elétrica). Para o projeto da topologia proposta, nesta tese, adicionalmente ao método analítico, foram realizadas simulações computacionais para a comparação e refinamento dos resultados das grandezas eletromagnéticas da máquina. / DC motors haves been used for almost two centuries. They are very well known not only its excellent torque response, but also because they can operate at the flux weakening region, when this situation is required. Due these characteristics, nowadays, the dc machines haves been used in specific niches of utilization. Nonetheless, this sort of machine presents a disadvantage, specifically the problem of exhaustive electromechanical maintenance required. In order to solve this type of problem, during the 1960\'s, the permanent magnet trapezoidal brushless dc machines were developed. The problem in this kind of machine is the dificulty to obtain excitation flux variation, since there is only a permanent magnet excitation system. Hence, the aim of this thesis is a study of non conventional electric machines topology for application and utilization in electric traction systems for operation at weakening flux region through the changing of resulting air-gap flux. As purpose of the study, an axial flux hybrid excitation topology was focused, i.e, a double excitation system (a permanent excitation and an electric excitation) to make its operation at the constant power region possible keeping the flux density level in the critical parts of the machine under the saturation point. Additionally, for design the topology proposed, in this thesis, computational simulations were done in order to compare with the results obtained from the analytical method.
407

Metodologia para atendimento de novas cargas em sistemas de distribuição de energia elétrica. / Methodology for assessing the impact for new loads in eletric power distribution systems.

Tello Ortíz, Elvis Richard 31 March 2009 (has links)
Nos países em desenvolvimento, como o Brasil, novos requerimentos de conexão às redes elétricas são solicitados constantemente como conseqüência do crescimento econômico e da conseqüente expansão da rede elétrica. Uma empresa distribuidora que atenda a uma cidade de grande porte recebe a cada mês um elevado número de solicitações de conexão de novas cargas. Assim, um dos principais desafios das áreas de projeto das empresas distribuidoras é encontrar a melhor forma, tanto técnica como economicamente, de atender a estas solicitações. Devido ao volume do trabalho envolvido, bem como à escassez de dados detalhados da rede elétrica, a prática convencional estabelece filtros para reduzir o número de estudos associados às novas cargas. Normalmente, estes filtros são baseados em um valor limite de demanda máxima. Se a nova carga possui uma demanda máxima inferior ao limite, a nova carga é ligada diretamente, sem a execução de estudos elétricos. Se, por outro lado, a demanda máxima da nova carga excede o limite, então um estudo detalhado é iniciado. Esta prática pode levar a duas decisões equivocadas por parte da empresa: (i) não-execução de um estudo quando ele era necessário, e (ii) execução de um estudo desnecessariamente. A situação de escassez de dados detalhados está mudando rapidamente nos últimos anos no mundo da distribuição de energia elétrica. Há atualmente poderosos sistemas geo-referenciados que permitem associar cada elemento da rede elétrica a uma posição geográfica bem definida. Além disso, estes sistemas contam com o apoio de bases de dados que possuem recursos para cadastrar e administrar o enorme volume de dados associados às redes de distribuição de energia elétrica. Esta nova realidade conduz naturalmente ao desenvolvimento de modelos mais sofisticados que permitem aprimorar muito a qualidade dos serviços prestados pelas empresas distribuidoras. Este trabalho propõe, desenvolve e implementa uma nova metodologia de apoio à decisão no que se refere à ligação de novas cargas em redes de distribuição de energia elétrica. A metodologia está baseada no conceito inovador de folga de potência, estabelecido no âmbito deste trabalho, pelo qual calcula-se a priori e em cada ponto da rede a máxima carga que pode ser conectada sem que os critérios técnicos, de tensão mínima e máximo carregamento, sejam transgredidos. A natureza da metodologia proposta elimina automaticamente a possibilidade de ocorrência das duas decisões equivocadas comentadas anteriormente. A utilização da metodologia desenvolvida é ilustrada através de diversos exemplos de aplicação que utilizam redes reais de distribuição, em baixa e média tensão. / Economic growth and the associated expansion of the electrical power system naturally lead to a large number of new loads being connected to the existing network. As a consequence, one of the main challenges faced by the design areas in electrical utilities refers to the problem of finding the best solution among various alternatives for connecting a new load, from both technical and economic viewpoints. Owing to the large size of the problem, and also to the lack of detailed data associated with distribution systems, electrical utilities adopted in the past a few filtering techniques so as to reduce the amount of work to reasonable levels. These filters usually define a limit for the maximum demand declared by a new customer. If the required maximum demand does not exceed the limit, the new load is connected straight away without carrying out any electrical study. On the other hand, when the maximum demand does exceed this limit, a detailed analysis is executed. Despite the savings brought about by this technique, it may lead to two potentially wrong decisions: (i) overseeing a detailed analysis when it is needed, and (ii) carrying out a study when it is not necessary. Concerning the lack of detailed data, fortunately this situation has been improving rapidly in the last few years. Currently, there exist powerful georreferenced systems capable of associating every component of the electrical system with a well-defined geographical location. These systems usually rely on supporting databases which allow efficient management of the huge amount of data normally associated with distribution networks. This new standpoint naturally leads to the development of more sophisticated models which allow considerable improvements on the quality of services offered by the utilities. This work presents a new methodology aimed at supporting the decision-making process regarding the connection of new loads in electrical distribution networks. The methodology is based upon the innovative concept of capacity margin, established within this work, by which the maximum load that can be connected to any given point is computed in advance in offline mode. The criteria for finding the maximum load are based on the common requirements of minimum voltage and maximum loading. The proposed methodology automatically eliminates the two wrong decisions mentioned above. The application of the proposed methodology is illustrated through various examples which use real distribution networks, at both low and medium voltage levels.
408

Absorção e dispersão de microondas em sistemas amorfos / Absorption and dispersion of microwaves in amorphous systems

Bergo, Paulo Victor Albuquerque 03 February 2005 (has links)
A dispersão e absorção das ondas eletromagnéticas que se propagam através de um material dielétrico podem ser medidas ao longo de uma ampla região do espectro que se estende desde a região de freqüências extremamente baixas até a região óptica incluindo as faixas das microondas, objeto de interesse do presente estudo. Dentre os dielétricos, incluem-se os materiais cristalinos e amorfos isolantes e semicondutores. Os vidros de composições (1-x)(60\'P IND. 2\'\'O IND.5\'.\'40\'BA\'\'O).x(\'M\'\'O\'), (1-X)(25\'LI IND. 2\'\'O\'.25\'NA IND. 2\'\'O\'.50\'P IND. 2\'\'O IND. 5\').x(\'M\'\'O\') e 60\'B IND. 2\'\'O IND. 3\'.30\'BA\'\'O\'.\'10\'AL IND. 2\'\'O IND. 3\' onde x é a concentração (mol%) de óxido do metal de transição \'FE\' ou \'CO\' (\'M\'\'O\'), foram escolhidos para representar o comportamento das propriedades dielétricas dos vidros óxidos, tanto na região das freqüências mais baixas (0 - 100 MHz), como na faixa de microondas (2 - 30 GHz). Os íons de metais de transição, quando ocupam posições intersticiais da rede vítrea, como ocorre com os elementos modificadores alcalinos e alcalinoterrosos atuam como compensadores de carga junto às unidades estruturais tetraédricas eletricamente carregadas, formando dipolos permanentes locais, contribuindo para a constante dielétrica do vidro. A polarização desses dipolos, quando submetido ao campo elétrico oscilatório de uma onda eletromagnética, atinge valores maiores às freqüências mais baixas decrescendo gradualmente à medida que estas atingem a região de microondas. Um novo método alternativo foi desenvolvido para a medida da temperatura da transição vítrea (\'T IND. g\') utilizando técnicas de microondas. Mostramos que a posição da inflexão do gráfico da constante dielétrica em função da temperatura do vidro 25\'LI IND. 2\'\'O\'.25\'NA IND. 2\'\'O\'.50\'P IND. 2\'\'O IND. 5\' medida em 9 GHz, na faixa de temperaturas em torno de \'(270 \'+ OU -\' 10) GRAUS\' C coincidiu com o valor da \'T IND. g\' deste vidro obtida por análise térmica diferencial (DTA). Outro método também foi desenvolvido para monitorar o resfriamento do vidro em função do tempo a partir do estado liquido até a solidificação, registrando o sinal de microondas refletido sobre o material vertido no interior de um guia de ondas. Pudemos observar, também, mudanças no espectro de ressonância paramagnética eletrônica (EPR) do vidro fosfato contendo níquel após ter sido irradiado com diferentes níveis de potência das microondas, por cerca de duas horas. Este efeito pode estar relacionado com mecanismos de acoplamento de spins paramagnéticos. Os espectros de transmissão de microondas das amostras de vidros fosfatos contendo diferentes concentrações de cobalto, bário, ferro e manganês, obtidos por meio de uma varredura de freqüências desde 7 até 13 GHz, mostraram a presença de uma intensa atenuação do sinal próximo de 9,7 GHz. Essa atenuação diminuiu conforme aumenta a concentração dos modificadores. / The dispersion and absorption of electromagnetic waves that propagate through a dielectric material can be measured along a wide spectral region ranging from extremely low frequency to the optical region, including microwaves one, which is the subject of interest of the present study. Among dielectrics, there are crystalline and amorphous materials that can be either insulators or semiconductors. Glasses of compositions (1-x)(60\'P IND. 2\'\'O IND.5\'.\'40\'BA\'\'O).x(\'M\'\'O\'), (1-X)(25\'LI IND. 2\'\'O\'.25\'NA IND. 2\'\'O\'.50\'P IND. 2\'\'O IND. 5\').x(\'M\'\'O\') and 60\'B IND. 2\'\'O IND. 3\'.30\'BA\'\'O\'.\'10\'AL IND. 2\'\'O IND. 3\', where x is the concentration (mol %) of the \'FE\' or \'CO\' (\'M\'\'O\') transition metal oxide, were selected to investigate the behavior of the dielectric properties of oxide glasses in the lower frequency range (0 - 100 MHz) and in the microwave region (2- 30 GHz). When transition metal ions occupy interstitial positions in the glass matrix, as it happens with the regular alkaline and alkaline-earth modifier ions, they compensate the electrically charged tetrahedral structural units. As a consequence, local permanent dipoles are formed, contributing to the dielectric constant of the glass. The polarization of these dipoles, when submitted to an oscillating electromagnetic field, is higher at lower frequencies and decreases gradual1y as the frequency approaches the microwave region. An alternative new method was developed to measure the glass transition temperature (\'T IND. g\') using microwave techniques. It was shown that the inflexion position of the dielectric constant of the glass 25\'LI IND. 2\'\'O\'.25\'NA IND. 2\'\'O\'.50\'P IND. 2\'\'O IND. 5\' measured at 9 GHz, in the temperature range about \'(270 \'+ OU -\' 10) GRAUS\' C, coincided with the \'T IND. g\' value obtained by differential thermal analysis (DTA). Another method was also developed for monitoring the melt cooling as a function of time from the liquid to the solid state, by recording the reflected microwave signal crossing the material poured inside the wave guide. We observed, also, changes in the electronic paramagnetic resonance (EPR) spectrum of phosphate glass containing nickel after being irradiated for two hours with several microwave power levels. This effect may be related with coupling and decoupling mechanisms among the spin clusters developed in the sample. The microwave transmission spectra of the phosphate glass samples containing different concentrations of iron, cobalt, barium, manganese and barium, obtained by a frequency sweep from 7 to 13 GHz, presented an intense attenuation of the signal near to 9,7 GHz. This attenuation was found to decrease with the increase of modifier content.
409

A contribuição da conservação de energia elétrica em instalações residenciais e seu impacto no planejamento da expansão da geração futura, com base na análise do Programa de Eficiência Energética - PEE desenvolvidas pelas concessionárias de energia elétrica no Brasil /

Santos, Rodolfo Esmarady Rocha dos. January 2018 (has links)
Orientador: Pedro Magalhães Sobrinho / Coorientador: Jamil Haddad / Banca: Celso Eduardo Tuna / Banca: Teófilo Miguel de Souza / Banca: Roberto Akira Yamachita / Banca: Christian Jeremi Coronado Rodriguez / Resumo: O Programa de Eficiência Energética (PEE) das distribuidoras de energia elétrica é, atualmente, o principal mecanismo de destinação de recursos para a promoção do uso racional de energia no Brasil. Ao longo do período de 2000 a 2017, este instrumento proporcionou importantes alterações, como a implementação da Lei nº 12.212/2010, que determinou a aplicação da maior parcela dos recursos aos projetos de iluminação, troca de refrigeradores, reforma das instalações elétricas e aquecedores destinados a população de baixa renda. Neste contexto, para este estudo, foi desenvolvido um Software de Análise PEE responsável pela seleção das informações dos relatórios propostos e realizados do PEE, disponibilizado pela Agência Nacional de Energia Elétrica (ANEEL), possibilitando o acesso às informações relevantes contidas nos projetos. Em posse desses dados, foi possível determinar a economia de energia total de 3.190,12 GWh e redução de demanda na ponta de 1.168,05 MW para o período de análise abordado de 2009 a 2015, para os usos finais em iluminação e refrigeração. Na sequência do estudo, foi realizada uma avaliação sobre o impacto ambiental relacionado à redução de emissão de CO2, com a aplicação da metodologia proposta para o PEE da ANEEL, e pode-se verificar que foi evitada a emissão total de 1.244.457,02 tCO2 para o uso final em iluminação e 169.570,05 tCO2 para refrigeração (refrigerador), totalizando 1.414.027,07 tCO2 ao longo do período de 2009 a 2015. O foco principal desse estu... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The Energy Efficiency Program (PEE) of energy distributors is currently the main mechanism for allocating resources for the advancement of rational energy use in Brazil. Over the period from 2000 to 2017, this tool has undergone important changes, such as the implementation of Law 12,212 / 2010, which has determined the application of most of the resources to lighting projects, fridge replacement, electrical and heaters installation aimed at a low-income population. In this context, a PEE Analysis Software was developed for this study, which was used to select information from PEE proposed and performed reports, provided by the National Electric Energy Agency (ANEEL), allowing access to the relevant information contained in the projects. Based on these data, it was possible to determine a total energy saving of 3,190.12 GWh and demand reduction at peak of 1,168.05 MW for the analysis period from 2009 to 2015. Following the study, it was conducted an assessment on the environmental impact related to CO2 emission reduction, with the application of the methodology proposed for the ANEEL PEE, and it can be verified a total emission of 1,244,457.02 tCO2 for the end use in illumination and 169,570.05 tCO2 for cooling (fridge), totalizing 1,414,027.07 tCO2 over the period from 2009 to 2015. The study main focus was the development of the new Cost-benefit Ratio (RCB), where an RCB between 0.10 and 0.18 was obtained for the end use in lighting for traditional calculations and RCB between 0.08 to 0.17 adopting the Certified Emissions Reductions (CERs) calculated with the reduction of CO2, proving that both results were lower than the maximum established by ANEEL, thus providing a significant contribution to the other SES projects. For the end use in cooling, the results presented a traditional RCB between 0.97 and 1.62 and, increasing the CERs, ... (Complete abstract click electronic access below) / Doutor
410

Desenvolvimento de uma plataforma digital para a minimização da vibração e da ondulação de torque de um motor de relutância chaveado. / Development of a digital test setup for minimizing the torque ripple and the vibration of a swiched reluctance motor.

Corrêa, Daniel Augusto Prudente 14 August 2009 (has links)
A finalidade inicial deste estudo é desenvolver uma metodologia de análise da ondulação de torque de um motor de relutância chaveado especial bifásico com 4 pólos no estator e 2 no rotor (MRC 4/2) através de dados experimentais de aceleração. De forma a validar o método proposto, são apresentados resultados experimentais de aceleração obtidos com dois rotores: o rotor de referência e o rotor otimizado. Uma vez alcançados os objetivos de otimização do torque através da modificação da geometria do rotor, implementou-se um estudo complementar de modo a explorar a vibração e a ondulação de torque, do ponto de vista do acionamento. Desta forma, desenvolveu-se uma plataforma digital de testes, onde os dados de aceleração podem ser monitorados no domínio da frequência, e os parâmetros de controle do acionamento, tais como, a velocidade, os ângulos de ligamento e condução são flexíveis e podem ser alterados através de programa. A plataforma digital foi concebida a partir de um kit de desenvolvimento (eZdsp LF2407A) associado a uma interface de controle serial, desenvolvida a partir de um aplicativo LabView, instalado num microcomputador. / The initial purpose of this study is to develop a methodology of analysis of the torque ripple of a two-phase special SRM 4/2 using acceleration experimental data. In order to validate the proposed method, acceleration experimental results are presented, these results were obtained with two rotors: the reference rotor and the optimized rotor. Once the torque optimization objectives were reached by modifying the rotor geometry, a complementary study from the point of view of motor drive vibration and torque ripple optimization was carried out. Thus, a test digital setup was developed, where the acceleration data could be monitored, in the frequency domain, and the drive control parameters, such as speed, turn-on and dwell angles, and phase current were flexible and could be altered by program. The test digital setup was conceived using a development kit (eZdsp LF2407A) associated with a serial control interface developed on a LabView application, installed in a microcomputer.

Page generated in 0.2835 seconds