• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 7
  • 2
  • Tagged with
  • 35
  • 35
  • 20
  • 20
  • 16
  • 15
  • 11
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Comportamento tribocorrosivo do aço inoxidável e de ligas de titânio em meio salino / Tribocorrosion behavior of stainless steel and titanium alloys in saline medium

Danillo Pedro Silva 16 October 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / No presente trabalho, foram realizados ensaios de tribocorrosão no aço inoxidável AISI 304L, no titânio comercialmente puro (CPTi) e na liga de titânio Ti6Al4V em solução aquosa de 0,90% m/v NaCl. Amostras de ligas de titânio com tratamento térmico superficial de refusão a laser também foram utilizadas. Um tribômetro do tipo pino-no-disco com contracorpo de alumina foi usado. Técnicas eletroquímicas in situ de monitoramento em circuito aberto, espectroscopia de impedância eletroquímica, curvas de polarização e amperimetria de resistência nula foram empregadas. Os resultados obtidos indicam que o desgaste tribocorrosivo das ligas de titânio é mais intenso do que o observado no aço inoxidável, apresentando perfis de superfície mais irregulares. A análise da impedância eletroquímica mostrou que todos os materiais utilizados apresentam uma rápida recuperação da camada passiva, exibindo módulos e fases um pouco menores do que os medidos antes do desgaste. Sob atrito, os diagramas de impedância apresentam uma forte redução do módulo. Sob desgaste, o expoente α do elemento de fase constante (CPE) atinge seu valor mais baixo, enquanto o parâmetro γ é máximo. As curvas de polarização exibem potenciais menores e densidades de corrente de corrosão maiores durante o desgaste. O tratamento de refusão a laser, embora mude a microestrutura e a dureza superficial das amostras, não indica uma mudança aparente nos parâmetros eletroquímicos sob tribocorrosão, bem como do coeficiente de atrito. Nos ensaios de amperimetria de resistência nula, foi possível estimar a corrente mensurada no ARN por meio do emprego de um circuito elétrico equivalente. A densidade espectral de potência dos sinais de potencial e de corrente exibe a frequência de rotação (1,25 Hz) e seus harmônicos. Para baixas frequências (abaixo de 10 mHz), o decaimento obedece à relação 1 ⁄ e 1⁄ para os sinais de potencial e corrente, respectivamente. / In this study, tribocorrosion tests were performed in stainless steel AISI 304L, commercially pure titanium (CPTI) and Ti6Al4V titanium alloy in 0.9% m/v NaCl aqueous solution of. Titanium alloy sample with laser remelting treatments were also tested. A pin-on-disc tribometer with alumina counterbody was used. In situ electrochemical techniques of open circuit monitoring, electrochemical impedance spectroscopy, polarization curves and zero resistance ammeter were employed. Results indicate tribocorrosion wear of titanium alloys is more intense than that observed in stainless steel, presenting more irregular surface profiles. Analysis of electrochemical impedance spectroscopy showed all materials used have a fast recovery of the passive layer, showing modulus and phase slightly smaller than those measured prior to wear. Under friction, impedance diagrams show a strong reduction of the modulus. Under rubbing, exponent α of the constant phase element (CPE) reaches its lowest value, while γ parameter is maximum. Polarization curves show lower corrosion potential and higher corrosion current density during rubbing. Laser remelting treatments, although changes microstructure and surface hardness of the samples, does not indicate an apparent change in electrochemical parameters under tribocorrosion, as well as in coefficient of friction. In zero resistance ammeter tests, it was possible to estimate the current measured in ZRA using an electrical equivalent circuit. Power spectral density of the potential and current signals exhibits the rotation frequency (1.25 Hz) and its harmonics. For lower frequencies (below 10 mHz), the decay follows 1⁄ and 1⁄ roll-off for signals of potential and current, respectively.
32

AVALIAÇÃO DO DESEMPENHO DE CONCRETOS COM ADIÇÕES MINERAIS QUANTO À CORROSÃO DAS ARMADURAS INDUZIDA POR CLORETOS / Performance evaluation of concretes content with mineral additions in relation to the reinforcing steels corrosion induced by chlorides

OLIVEIRA, Andrielli Morais de 29 August 2007 (has links)
Made available in DSpace on 2014-07-29T15:03:38Z (GMT). No. of bitstreams: 1 dissertacao Adrielli.pdf: 5370662 bytes, checksum: 4e167ff0f119f9298b4d7ed2791baa06 (MD5) Previous issue date: 2007-08-29 / The present work aims to study the performance of concrete with regard to the action of chloride ions, evaluating the influence of both mineral additions and water/binder ratio (w/b), considering kinetic and thermodynamic aspects of the corrosive phenomenon. A experimental research was carried out considering the following variables: the presence of mineral additions in partial substitution to the cement weight (10% of silica fume; 25% of fly ash; 10%, 20% and 30% of metakaolin) and the water/binder ratio (0,40 and 0,55). Thus, cubic concrete test specimens were produced, in addition to cylindrical test specimens for concrete characterization in relation to the compressive strength, specific mass, void ratio and capillary water absorption. After 645 days of casting, the cubic concrete test specimens were submitted to the chlorides attack during 308 days, totality 44 weekly cycles of immersion in chlorides aggressive solution. They were monitored, throughout this period, by means of techniques, such as: the concrete electric resistivity, the half-cell potential, the polarization resistance and the electrochemical impedance spectroscopy. At the end of the experiment, visual inspections of reinforcing steels allowed to observe their superficial aspects after attack. As general result, it was gotten that the incorporation of mineral additions to the concretes promoted significant profits in all the evaluated properties, evidencing the beneficial effect of these additions in concretes exposed to aggressive conditions, specially in those in which there are chloride ions. In this direction, the statistical analysis has shown evidences that concretes with silica fume and metakaolin achieved the best results of electrical resistivity. In relation to the half-cell potentials, the reference concrete (without mineral additions) presented the worst performance, with an indication of despassivation in the reinforcing steels accentuated fall in the values of resistance of polarization with the time, proving the susceptibility of these systems to the action of chlorides. The concrete with mineral additions did not present depassivation of the reinforcing steels meaning that these systems possess great durability and service life in relation to those without mineral additions / O presente trabalho tem como objetivo estudar o desempenho de concretos quanto à ação de íons cloreto, avaliando tanto a interveniência das adições minerais incorporadas ao concreto quanto da relação água/aglomerante (a/ag), considerando aspectos cinéticos e termodinâmicos do fenômeno corrosivo. Para tanto, desenvolveu-se uma pesquisa experimental que contemplou as seguintes variáveis: a presença de adições minerais em substituição parcial à massa de cimento (10% de sílica ativa; 25% de cinza volante; 10%, 20% e 30% de metacaulim) e a relação água/aglomerante (0,40 e 0,55). Foram moldados corpos-de-prova cúbicos, além de corpos-de-prova cilíndricos para caracterização dos concretos quanto à resistência à compressão, massa específica, índice de vazios e absorção de água por capilaridade. Após 645 dias de moldagem, os corpos-de-prova cúbicos de concreto foram submetidos ao ataque por cloretos durante 308 dias, totalizando 44 ciclos semanais de imersão em solução agressiva e posterior secagem em ambiente de laboratório. Foram monitorados, ao longo deste período, a resistividade elétrica desses concretos, os potenciais de corrosão, a resistência de polarização e a impedância eletroquímica. Ao fim do experimento, inspeções visuais à armadura permitiram observar o seu aspecto superficial após o período de ataque. Como resultado geral, obteve-se que a incorporação de adições minerais aos concretos promoveu ganhos significativos em todas as propriedades avaliadas, evidenciando o efeito benéfico dessas adições em concretos submetidos às condições agressivas, sobretudo contendo íons cloreto. Nesse sentido, a análise estatística evidenciou que os concretos com sílica ativa e com metacaulim obtiveram os melhores resultados de resistividade elétrica. Quanto aos potenciais de corrosão, os concretos de referência (sem adições minerais) apresentaram desempenho inferior, com a indicação da despassivação das armaduras e a queda acentuada nos valores de resistência de polarização com o tempo, comprovando a susceptibilidade desses sistemas à ação de cloretos. Os concretos com adições minerais não apresentaram despassivação das armaduras, denotando que esses sistemas possuem maior durabilidade e vida útil em comparação àqueles referentes aos concretos sem adição mineral, tendo em vista o ataque por cloretos
33

Avaliação da capacidade de proteção contra a corrosão da arma-dura induzida por cloretos de concretos com adições minerais e inibidores de corrosão / Evaluation of the ability to protect against corrosion of the gun hard-induced chloride concrete with mineral additions and corrosion inhibitors

LIMA, Marcelo Batista 28 September 2009 (has links)
Made available in DSpace on 2014-07-29T15:18:24Z (GMT). No. of bitstreams: 1 pretextual.pdf: 140883 bytes, checksum: 5d9ee4b9b3884a0032825e604304580f (MD5) Previous issue date: 2009-09-28 / Increasing the durability of concrete structural elements is primordial, especially those related to power generation in eolic areas that are subjected to the phenomenon of reinforcement corrosion. In this context, this study aims to evaluate the overall protection ability of concrete to the phenomenon of reinforcement corrosion induced by chlorides. To this end, it was adopted a statistical program based on a fractional factorial design in which the variables studied were as follows: the water-binder ratio (0.35, 0.45 and 0.55), the type of mineral admixture (silica fume and blast furnace slag at specific levels), the type of corrosion inhibitor (calcium nitrite, sodium nitrite and amine) and the level of corrosion inhibitor (minimum and maximum recommended by each manufacturer). In the concrete investigations, the tests performed were corrosion potential, polarization resistance and electrochemical impedance. Throughout the experiments, it was possible to testify the beneficial effect of reducing the water-binder ratio. It was also possible to prove the very positive effect of the incorporation of mineral admixtures, especially of silica fume. The satisfactory performance of various inhibitors evaluated was also verified, specially when concrete contains mineral admixtures. A parallel study was conducted to make a comparative analysis of inhibitors at the same range of concentrations (at solid levels of 0.76%, 2.21% and 3.66% of the compound on the cement mass), nevertheless this study have demonstrated that fixing contents for all inhibitor is not appropriated, and the recommended dosages by the manufacturer is the best condition. As the levels recommended by manufacturers, it was found that the higher percentages have not worked well for sodium nitrite otherwise, for amine and nitrite calcium, the higher levels implied better results. Regarding the tannin inhibitor also assessed in the parallel study mentioned above (related to specific inhibitors), its good performance related to corrosion inhibition happened just for the content of 0.76% (the lowest levels). For the other contents, it was verified anomalous results. These results demonstrated that each type of corrosion inhibitor has its optimal concentration for use in concrete. Based on a cost-benefit analysis and evaluating the increase in the concrete value for cubic meter (in R$) in the presence of inhibitors at the same contents, it was verified a relative parity prices among the tested nitrites and an extremely high cost of amine. However, when performing the same analysis but using the levels recommended by the manufacturers for each inhibitor independent, it was found that the large disparity in prices between nitrite and amine was reduced considerably. An assessment of technical and economic feasibility was also performed based on the efficiency of corrosion inhibition and cost per cubic meter of concrete mixtures that did not show a typical depassivation of their stell bar up to the attack age evaluated / O aumento da durabilidade é um aspecto primordial para os elementos estruturais de concreto, em especial aqueles constituintes das estruturas de geração de energia em parques eólicos, sujeitos ao fenômeno de corrosão das armaduras. Nesse contexto, este trabalho tem como objetivo geral avaliar a capacidade de proteção de diferentes concretoS frente ao fenômeno da corrosão da armadura induzida por cloretos. Para tanto, foi adotado um planejamento estatístico baseado em um modelo fatorial fracionado em que as variáveis estudadas foram: a relação água/aglomerante (0,35; 0,45 e 0,55), o tipo de adição mineral (sílica ativa e escória de alto-forno, em teores específicos), o tipo de inibidor de corrosão (nitrito de cálcio, nitrito de sódio e amina) e o teor de inibidor de corrosão (mínimo e máximo recomendado por cada fabricante). Na avaliação dos concretos, foram realizados ensaios de potencial de corrosão, resistência de polarização e impedância eletroquímica. Ao longo de todo experimento foi possível constatar o efeito benéfico da redução da relação a/agl. Também foi possível verificar o efeito extremamente positivo da incorporação das adições minerais, em especial da sílica ativa. Constatou-se também o efeito positivo dos diversos inibidores avaliados, em seus teores mínimo e máximo, beneficio que se mostrou mais pronunciado quando da utilização conjunta com as adições minerais. Um estudo paralelo foi realizado para se fazer uma análise comparativa dos inibidores dentro da mesma faixa de teores empregados (teores de 0,76%; 2,21% e 3,66% de sólidos do aditivo em relação à massa de cimento), no qual se verificou que a utilização desses teores fixos para os diferentes tipos de inibidores não se mostrou tão eficiente quanto em relação à utilização dos aditivos na dosagem de recomendação do fabricante. Quanto a estes teores (recomendados pelos fabricantes), verificou-se que os percentuais mais altos não funcionaram bem para o nitrito de sódio, ao passo que para a amina e para o nitrito de cálcio os teores mais elevados resultaram em melhores resultados. Em relação ao tanino, inibidor que também foi avaliado no estudo paralelo referido anteriormente (específico sobre os inibidores), só houve algum resultado de inibição de corrosão para o teor de 0,76% (mais baixo dos teores), tendo-se obtido resultados anômalos para os outros 2 teores mais altos. Tais resultados permitiram constatar que cada tipo de inibidor de corrosão possui sua concentração ótima de utilização no concreto. Fazendo-se uma análise de custo e avaliando-se o acréscimo em Reais no valor do m3 do concreto proporcionado pelos diversos aditivos inibidores e nos teores de mesma faixa de emprego, verificou-se uma relativa paridade de preços entre os nitritos e um elevadíssimo custo da amina. No entanto, ao se realizar a mesma análise, mas utilizando os teores recomendados pelos fabricantes de cada inibidor, verificou-se que a grande disparidade de preços entre os nitritos e a amina foi reduzida de forma considerável. Uma avaliação da viabilidade técnico-econômica dos concretos também foi realizada, a partir dos dados de eficiência de inibição à corrosão e custo/m3 das misturas que não apresentaram comportamento típico de despassivação de suas armaduras até a idade de ataque considerada
34

DETERMINAÇÃO DE ÁCIDO α-LIPÓICO EMPREGANDO TÉCNICAS ELETROQUÍMICAS E ANÁLISE POR INJEÇÃO EM BATELADA / DETERMINATION OF α-LIPOIC ACID EMPLOYING ELECTROCHEMICAL TECHNIQUES AND ANALYSIS BY INJECTION IN BATCH

Pereira, Laise Nayra dos Santos 18 July 2014 (has links)
Made available in DSpace on 2016-08-19T12:56:48Z (GMT). No. of bitstreams: 1 Dissertacao LAISE NAYRA DOS SANTOS PEREIRA.pdf: 1329578 bytes, checksum: bb0923e1ddc2d57bb73b2390b4ceb375 (MD5) Previous issue date: 2014-07-18 / FUNDAÇÃO DE AMPARO À PESQUISA E AO DESENVOLVIMENTO CIENTIFICO E TECNOLÓGICO DO MARANHÃO / This work describes the development of electroanalytical procedures for α-lipoic acid (ALA) determination in dietary supplement using a pyrolitic graphite electrode (PG) modified with cobalt phthalocyanine (CoPc) from electrochemical techniques and by Batch Injection Analysis (BIA). Cyclic voltammograms of ALA oxidation on the PG/ CoPc electrode presented an irreversible peak ~+0.85 V vs Ag/ AgCl, a value about 100 mV to less positive potential, well as a significant increase in the magnitude of peak current compared to the PG electrode unmodified. The analytical curves obtained with cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry showed good linearity and sensitivity. The DPV technique showed the best values of limit of detection (LOD) and quantification (LOQ) 3.4 x 10ˉ⁹ mol Lˉ¹ and 1.2 x 10ˉ⁸ mol Lˉ¹, respectively. Therefore was chosen for determination of ALA on technique. Voltammetric response of ALA was also evaluated in PG electrode unimodified and modified in hydrodynamic conditions. The modification of the PG/ CoPc electrode produced an increase of 2.33 times compared to the PG electrode. The analytical method was then proposed using the PG/ CoPc electrode for detection of ALA by BIA. The method showed a good linear range between (1.0 x 10ˉ⁶ to 1.0 x 10ˉ⁴ mol Lˉ¹), values of LOD and LOQ of 1.5 × 10ˉ⁸ mol Lˉ¹ and 5.0 × 10ˉ⁸ mol L-1, respectively, with analytical frequency of 208 injections/ hour. The quantification of ALA in dietary supplement showed concordant results with those obtained by chromatographic method, with a confidence level of 95%. Recovery tests were performed added a concentration of ALA in a sample of synthetic urine, where the recovery values were in the range 98 - 107%. / O presente trabalho descreve o desenvolvimento de procedimentos eletroanalíticos para determinação de ácido α-lipóico (ALA) em suplemento dietético utilizando eletrodo de grafite pirolítico (GP) modificado com ftalocianina de cobalto (CoPc) a partir de técnicas eletroquímicas e pela Análise por Injeção em Batelada (BIA). Os voltamogramas cíclicos da oxidação de ALA sobre o eletrodo GP/ CoPc apresentaram um pico irreversível com potencial ~ +0,85 V vs. Ag/ AgCl, mostrando um deslocamento do início da corrente de oxidação em cerca de 100 mV para potenciais menos positivos, bem como um aumento significativo na magnitude da corrente de pico, quando comparados ao eletrodo não modificado GP. As curvas analíticas obtidas com as técnicas de voltametria cíclica (VC), voltametria de pulso diferencial (VPD) e cronoamperometria apresentaram boa linearidade e sensibilidade. A técnica de VPD apresentou os melhores valores de limite de detecção (LD) e de quantificação (LQ), 3,4 x 10ˉ⁹ mol Lˉ¹ e 1,2 x 10ˉ⁸ mol Lˉ¹, respectivamente. Portanto foi a técnica escolhida para determinação de ALA. Resposta voltamétrica do ALA também foi avaliada no eletrodo GP não modificado e modificado em condições hidrodinâmicas. A modificação do eletrodo GP/ CoPc produziu um aumento de 2,33 vezes comparado com o eletrodo GP. O método analítico foi então proposto usando o eletrodo GP/ CoPc para detecção de ALA por BIA. O método apresentou uma boa faixa linear compreendida entre (1 x 10ˉ⁶ a 1 x 10ˉ⁴ mol Lˉ¹); valores de LD e LQ de 1, 5 x 10ˉ⁸ mol Lˉ¹ e 5, 0 x 10ˉ⁸ mol Lˉ¹, respectivamente, com frequência analítica de 208 injeções/ hora. A quantificação de ALA em suplemento dietético apresentou resultados concordantes com os obtidos pelo método cromatográfico, apresentando um nível de confiança de 95%. Testes de recuperação foram feitos adicionados uma concentração de ALA em amostra de urina sintética, onde os valores de recuperação foram na faixa de 98 a 107%.
35

Investigating the Electrochemical Interaction of Microorganisms with MetalSurfaces During Microbiologically Influenced Corrosion

Sadek, Anwar 11 August 2022 (has links)
No description available.

Page generated in 0.1056 seconds