Spelling suggestions: "subject:"electrocardiography"" "subject:"electrochromatography""
1 |
Applying the Short-Time Direct Directed Transfer Function to Human Electrocorticographic Recordings from a Language TaskWhaley, Meagan 28 June 2013 (has links)
This thesis applied the short-time direct directed transfer function (SdDTF) to time series data recordings from intracranial electrodes that measure the
brain's electrical activity to determine the causal influences that occurred between brain regions during a speech production task. The combination of high temporal and spatial resolution of the electrocorticography (ECoG) recordings directly from the cortex render these measurements of brain activity desirable, particularly when analyzing the fine cognitive dynamics involved in word generation. This research applied a new method to characterize the SdDTF results by compressing across time and high gamma frequencies, generating adjacency matrices, and graphing them to visualize the influences between anatomical regions over the duration of the entire task. This consolidated SdDTF analysis technique allowed for data from a total of seven patients to be combined, generating results which were consistent with current speech production models. The results from this thesis contribute to the expansion of language research by identifying areas relevant to word generation, providing information that will help surgeons avoid irreparable damage to crucial cortex during brain surgery.
|
2 |
Engineering Approaches for Improving Cortical Interfacing and Algorithms for the Evaluation of Treatment Resistant EpilepsyJanuary 2015 (has links)
abstract: Epilepsy is a group of disorders that cause seizures in approximately 2.2 million people in the United States. Over 30% of these patients have epilepsies that do not respond to treatment with anti-epileptic drugs. For this population, focal resection surgery could offer long-term seizure freedom. Surgery candidates undergo a myriad of tests and monitoring to determine where and when seizures occur. The “gold standard” method for focus identification involves the placement of electrocorticography (ECoG) grids in the sub-dural space, followed by continual monitoring and visual inspection of the patient’s cortical activity. This process, however, is highly subjective and uses dated technology. Multiple studies were performed to investigate how the evaluation process could benefit from an algorithmic adjust using current ECoG technology, and how the use of new microECoG technology could further improve the process.
Computational algorithms can quickly and objectively find signal characteristics that may not be detectable with visual inspection, but many assume the data are stationary and/or linear, which biological data are not. An empirical mode decomposition (EMD) based algorithm was developed to detect potential seizures and tested on data collected from eight patients undergoing monitoring for focal resection surgery. EMD does not require linearity or stationarity and is data driven. The results suggest that a biological data driven algorithm could serve as a useful tool to objectively identify changes in cortical activity associated with seizures.
Next, the use of microECoG technology was investigated. Though both ECoG and microECoG grids are composed of electrodes resting on the surface of the cortex, changing the diameter of the electrodes creates non-trivial changes in the physics of the electrode-tissue interface that need to be accounted for. Experimenting with different recording configurations showed that proper grounding, referencing, and amplification are critical to obtain high quality neural signals from microECoG grids.
Finally, the relationship between data collected from the cortical surface with micro and macro electrodes was studied. Simultaneous recordings of the two electrode types showed differences in power spectra that suggest the inclusion of activity, possibly from deep structures, by macroelectrodes that is not accessible by microelectrodes. / Dissertation/Thesis / Doctoral Dissertation Bioengineering 2015
|
3 |
Characterizing dynamically evolving functional networks in humans with application to speechStephen, Emily Patricia 03 November 2015 (has links)
Understanding how communication between brain areas evolves to support dynamic function remains a fundamental challenge in neuroscience. One approach to this question is functional connectivity analysis, in which statistical coupling measures are employed to detect signatures of interactions between brain regions. Because the brain uses multiple communication mechanisms at different temporal and spatial scales, and because the neuronal signatures of communication are often weak, powerful connectivity inference methodologies require continued development specific to these challenges.
Here we address the challenge of inferring task-related functional connectivity in brain voltage recordings. We first develop a framework for detecting changes in statistical coupling that occur reliably in a task relative to a baseline period. The framework characterizes the dynamics of connectivity changes, allows inference on multiple spatial scales, and assesses statistical uncertainty. This general framework is modular and applicable to a wide range of tasks and research questions.
We demonstrate the flexibility of the framework in the second part of this thesis, in which we refine the coupling statistics and hypothesis tests to improve statistical power and test different proposed connectivity mechanisms. In particular, we introduce frequency domain coupling measures and define test statistics that exploit theoretical properties and capture known sampling variability. The resulting test statistics use correlation, coherence, canonical correlation, and canonical coherence to infer task-related changes in coupling. Because canonical correlation and canonical coherence are not commonly used in functional connectivity analyses, we derive the theoretical values and statistical estimators for these measures.
In the third part of this thesis, we present a sample application of these techniques to electrocorticography data collected during an overt reading task. We discuss the challenges that arise with task-related human data, which is often noisy and underpowered, and present functional connectivity results in the context of traditional and contemporary within-electrode analytics. In two of nine subjects we observe time-domain and frequency-domain network changes that accord with theoretical models of information routing during motor processing.
Taken together, this work contributes a methodological framework for inferring task-related functional connectivity across spatial and temporal scales, and supports insight into the rapid, dynamic functional coupling of human speech.
|
4 |
Characteristic time courses of electrocorticographic signals during speechKuzdeba, Scott 07 October 2019 (has links)
Electrophysiology has produced a wealth of information concerning characteristic patterns of neural activity underlying movement control in non-human primates. Such patterns differentiate functional classes of neurons and illuminate neural computations underlying different stages of motor planning and execution. The scarcity of high-resolution electrophysiological recordings in humans has hindered such descriptions of brain activity during uniquely human acts such as speech production.
The goal of this dissertation was to identify and quantitatively characterize canonical temporal profiles of neural activity measured using surface and depth electrocorticography electrodes while pre-surgical epilepsy patients read aloud monosyllabic utterances. An unsupervised iterative clustering procedure was combined with a novel Kalman filter-based trend analysis to identify characteristic activity time courses that occurred across multiple subjects. A nonlinear distance measure was used to emphasize similarity at key portions of the activity profiles, including signal peaks. Eight canonical activity patterns were identified. These activity profiles fell broadly into two classes: symmetric profiles in which activity rises and falls at approximately the same rate, and ramp profiles in which activity rises relatively quickly and falls off gradually. Distinct characteristic time courses were found during four different task stages: early processing of the orthographic stimulus, phonological-to-motor processing, motor execution, and auditory processing of self-produced speech, with activity offset ramps in earlier stages approximately matching activity onset rates in later stages. The addition of an anatomical constraint to the distance measure to encourage clusters to form within local brain regions did not significantly change results. The anatomically constrained results showed a further subdivision of the eight canonical activity patterns, with the subdivisions primarily stemming from sub-clusters that are anatomically distinct across different brain regions, but maintained the base activity pattern of their parent cluster from the analysis without the anatomically constrained distance measure. The analysis tools developed herein provide a powerful means for identifying and quantitatively characterizing the neural computations underlying human speech production and may apply to other cognitive and behavioral domains.
|
5 |
Enhanced phase-amplitude coupling of human electrocorticography selectively in the posterior cortical region during rapid eye movement sleep / REM睡眠中のヒトの皮質脳波における位相-振幅間カップリングは、大脳後方皮質領域で選択的に高いTogawa, Jumpei 24 November 2022 (has links)
京都大学 / 新制・論文博士 / 博士(医学) / 乙第13513号 / 論医博第2263号 / 新制||医||1061(附属図書館) / 京都大学大学院医学研究科医学専攻 / (主査)教授 伊佐 正, 教授 村井 俊哉, 教授 高橋 淳 / 学位規則第4条第2項該当 / Doctor of Medical Science / Kyoto University / DFAM
|
6 |
Improved decoding for brain-machine interfaces for continuous movement controlMarathe, Amar Ravindra 20 April 2011 (has links)
No description available.
|
7 |
Cirugía de epilepsia en patología dual abordada con estimulación cortical directa y electrocorticografía intraoperatoria. Primer caso en el Hospital RebagliatiBarreto Acevedo, Elliot, Becerra Zegarra, Alicia, Villafuerte Espinoza, Mirla V., Llaja Rojas, Victoria 06 1900 (has links)
La coexistencia de esclerosis hipocampal con una lesión extrahipocampal potencialmente epileptógena, situación
conocida como patología dual, traza un reto para planificar la cirugía resectiva de epilepsia farmacorresistente.
Presentamos un caso de epilepsia focal farmacorresistente asociada a patología dual (esclerosis hipocampal
izquierda y gliosis frontal izquierda), abordada con estimulación eléctrica cortical directa y electrocorticografía
intraoperatoria, con buenos resultados a corto plazo. / The coexistence of hippocampal sclerosis with a potentially epileptogenic extra hippocampal injury is known as
dual pathology, and presents a challenge to resection surgery strategies in cases of drug-resistant epilepsy. We
present a case of drug-resistant focal epilepsy associated with dual pathology (left hippocampal sclerosis and left
frontal gliosis), treated by means of direct cortical electrical stimulation and intraoperative electrocorticography
with good short-term results.
|
8 |
Validation of a Flexible Bilayer Micro-Electrocorticography Array and Extraction of High-Frequency Features of Neuronal ActivityJanuary 2018 (has links)
abstract: Neural interfacing applications have advanced in complexity, with needs for increasingly high degrees of freedom in prosthetic device control, sharper discrimination in sensory percepts in bidirectional interfaces, and more precise localization of functional connectivity in the brain. As such, there is a growing need for reliable neurophysiological recordings at a fine spatial scale matching that of cortical columnar processing. Penetrating microelectrodes provide localization sufficient to isolate action potential (AP) waveforms, but often suffer from recorded signal deterioration linked to foreign body response. Micro-Electrocorticography (μECoG) surface electrodes elicit lower foreign body response and show greater chronic stability of recorded signals, though they typically lack the signal localization necessary to isolate individual APs. This dissertation validates the recording capacity of a novel, flexible, large area μECoG array with bilayer routing in a feline implant, and explores the ability of conventional μECoG arrays to detect features of neuronal activity in a very high frequency band associated with AP waveforms.
Recordings from both layers of the flexible μECoG array showed frequency features typical of cortical local field potentials (LFP) and were shown to be stable in amplitude over time. Recordings from both layers also showed consistent, frequency-dependent modulation after induction of general anesthesia, with large increases in beta and gamma band and decreases in theta band observed over three experiments. Recordings from conventional μECoG arrays over human cortex showed robust modulation in a high frequency (250-2000 Hz) band upon production of spoken words. Modulation in this band was used to predict spoken words with over 90% accuracy. Basal Ganglia neuronal AP firing was also shown to significantly correlate with various cortical μECoG recordings in this frequency band. Results indicate that μECoG surface electrodes may detect high frequency neuronal activity potentially associated with AP firing, a source of information previously unutilized by these devices. / Dissertation/Thesis / Doctoral Dissertation Biomedical Engineering 2018
|
9 |
Cortical Stimulation Mapping of Heschl’s Gyrus in the Auditory Cortex for Tinnitus TreatmentHuang, Austin 01 January 2019 (has links)
Tinnitus is the perception of sound in the absence of an actual sound stimulus. Recent developments have shifted the focus to the central nervous system and the neural correlate of tinnitus. Broadly, tinnitus involves cortical map rearrangement, pathological neural synchrony, and increased spontaneous firing rates. Various cortical regions, such as Heschl’s gyrus in the auditory cortex, have been found to be associated with different aspects of tinnitus, such as perception and loudness. I propose a cortical stimulation mapping study of Heschl’s gyrus using a depth and subdural electrode montage to conduct electrocorticography. This study would provide high-resolution data on abnormal frequency band oscillations characteristic of tinnitus and pinpoint regions where they occur. The validity of the neural synchrony model would also be tested in this study.
|
10 |
System Design and Evaluation of a Low Cost Epidural Intracranial Pressure Monitoring System, Integrable with ECoG ElectrodesJanuary 2015 (has links)
abstract: Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis.
Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and detecting seizure zones. However, ECoG electrodes cause a foreign body mass effect, swelling, and pneumocephaly, which results in elevation of intracranial pressure (ICP). Thus, the aim of this work is to design an intracranial pressure monitoring system that could augment ECoG electrodes.
A minimally invasive, low-cost epidural intracranial pressure monitoring system is developed for this purpose, using a commercial pressure transducer available for biomedical applications. The system is composed of a pressure transducer, sensing cup, electronics, and data acquisition system. The pressure transducer is a microelectromechanical system (MEMS)-based die that works on piezoresistive phenomenon with dielectric isolation for direct contact with fluids.
The developed system was bench tested and verified in an animal model to confirm the efficacy of the system for intracranial pressure monitoring. The system has a 0.1 mmHg accuracy and a 2% error for the 0-10 mmHg range, with resolution of 0.01 mmHg. This system serves as a minimally invasive (2 mm burr hole) epidural ICP monitor, which could augment existing ECoG electrode arrays, to simultaneously measure intracranial pressure along with the neural signals.
This device could also be employed with brain implants that causes elevation in ICP due to tissue - implant interaction often leading to edema. This research explores the concept and feasibility for integrating the sensing component directly on to the ECoG electrode arrays. / Dissertation/Thesis / Masters Thesis Bioengineering 2015
|
Page generated in 0.0931 seconds