Spelling suggestions: "subject:"endodontic"" "subject:"endodontia""
481 |
Análise física química e mecânica de um cimento experimental à base de MTAMassi, Santiago [UNESP] 31 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:45Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-03-31Bitstream added on 2014-06-13T18:56:26Z : No. of bitstreams: 1
massi_s_me_arafo.pdf: 223224 bytes, checksum: 277dcea4e6af26233b5a8ab30ff054dd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Modificações têm sido propostas ao MTA e cimento Portland para a obtenção de um cimento obturador de canal radicular. Um material experimental à base de MTA (CE-MTA) é avaliado neste estudo para emprego como cimento endodôntico, contendo cimento Portland, radiopacificador, aditivos e veículo. Assim, o objetivo deste estudo foi avaliar o cimento experimental, usando como parâmetros comparativos o cimento AHPlus (AHP), MTA-Angelus (MTA) e cimento Portland (CP). Foram realizados testes de tempo de presa; resistência à compressão; escoamento; radiopacidade; alteração do pH e liberação de íons cálcio. Todas as metodologias foram definidas usando como referência normas ISO e a literatura científica recente da área endodôntica. O teste de escoamento seguiu a metodologia proposta pela norma ISO, com a medição do diâmetro dos discos de cimento, assim como da área por meio de um programa de imagens. O tempo de presa foi avaliado pela norma da ADA/ASTM, verificando os períodos de tempo necessários para que as agulhas indentadoras (100g e 2mm de diâmetro na ponta; e 456g e 1 mm de diâmetro na ponta) não marcassem a superfície dos discos de cimento, fornecendo resultados para a presa inicial e final. No teste de radiopacidade foi feita uma comparação da radiopacidade de discos de cimento de 10mm de diâmetro e 1 mm de espessura, com uma escala de alumínio padronizada. A alteração de pH do foi avaliada com um pHmetro e a liberação de cálcio com um espectrofotômetro de absorção atômica. Para ambos os ensaios tubos preenchidos com o cimento foram imersos em frascos contendo água destilada. Os tubos foram passados para um novo frasco contendo mais água destilada nos períodos de tempo de 3, 6, 12, 24 e 48 horas, assim como 7, 14 e 28 dias. O líquido remanescente nos frascos foi avaliado para obter os resultados deste ensaio. Na resistência à compressão... / Modifications of MTA and Portland cement has been proposed to obtain an root canal sealer. This study evaluates an experimental MTA based root canal sealer (CE-MTA) which contains Portland cement, radiopacifier, addictives and a vehicle. The aim of this study was to evaluate the experimental endodontic sealer, using white Portland cement (CP), MTAAngelus(MTA) and AH Plus (AHP) as control groups. The tests realized were: setting time, radipacity, compressive strength, pH alterations, calcium release and flow. The flow test followed the ISO 6876 norms, and the the sealer discs’ area was measured with a paquimeter and using an area measurement software. The setting time was measured based on the ADA/ASTM Norm, allowing initial and final setting time measurements. Radiopacity was measured using an aluminum scale as reference and sealer discs with 10 mm in diameter by 1 mm thick. The pH was measured using a pHmeter and the calcium release using an atomic absorption spectrophotometer. For compressive strength test the ISO 9917 methodology was used, testing specimens at 24 hours and 21 days. All the data was submitted to statistical analysis, a normality test, and after the data normality check, an ANOVA and a Tukey test using 5% significance were applyed. Results: The results showed that CE-MTA has flow similar to AH Plus and superior to the minimum required by the ISO standard. The setting time was faster than AH Plus and slower than MTA and Portland cement. The compressive strength was lower for the experimental sealer at 24 hours time compared with all the tested materials, and similar for the experimental sealer and MTA at 21 days. The experimental sealer had a superior calcium release in all period of time, and higher pH values until 48 hours period, being similar to MTA and Portland cement on posterior time periods. The experimental sealer radiopacity was lower... (Complete abstract click electronic access below)
|
482 |
ANÁLISE COMPARATIVA DOS SISTEMAS DE INSTRUMENTO ÚNICO RECIPROC, WAVEONE E ONE SHAPE NA INCIDÊNCIA DE DEFEITOS DENTINÁRIOS / COMPARATIVE ANALYSIS OF RECIPROC, WAVEONE AND ONE SHAPE SINGLE-FILE SYSTEMS ON THE INCIDENCE OF DENTINAL DEFECTSPillar, Rafael 02 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Dentinal defects are characterized by cracks in the root dentin that can develop into a vertical root fractures (VRF), thus leading to tooth loss. Endodontic procedures may generate these defects and between these steps, the biomechanical preparations with NiTi rotary instruments are associated with the incidence of these amendments dentinal. A new concept in minimally invasive preparation was introduced, along with a new reciprocating movement, using a single instrument for root canal instrumentation. This allows less root dentin is removed, thus avoiding the weakening of tooth structure. The aim of this study was evaluate the incidence of dentinal defects after root canal preparation by three single-file systems. One hundred forty mesial roots of mandibular molars were selected and randomly assigned to 4 groups (n= 35 mesial roots per group). One group was left unprepared as control. In two groups, the root canals were instrumented by using the reciprocating single-file systems WaveOne (Dentsply-Maillefer) and Reciproc (VDW), while other group was prepared with single-file of continuous rotation One Shape (Micro-Mega). The specimens were sectioned in 03, 06 and 09 mm from the apex with a low-speed saw under water cooling (IsoMet 1000 Precision Saw) and observed through a stereomicroscope (Zeiss Stemi SV6, Carl Zeiss) at a magnification of 20×. The pictures were recorded and evaluated by two blinded calibrated observers. The slices were categorized in: 0- No defects; 1- Others defects and 2 vertical root fracture. The dates were statistically analyzed with a significance level set at α = 0.05. The chi-square and Fisher exact tests were used to assess the differences between groups. No defects were observed in control group. All the experimental groups showed dentinal defects. The reciprocating files were associated with more defects than the continuous rotary file and control group (P < 0.05), but no significant difference between them (P = .115). VRF was observed only in the One Shape group. The results of this study suggest that the biomechanical preparation could cause damage in the root dentin and that the continuous rotary has a tendency to result in fewer defects compared to reciprocating files. / Defeitos dentinários são caracterizados por trincas na dentina radicular que podem evoluir para uma Fratura Vertical da Raiz (FVR), levando assim a perda do elemento dentário. O preparo biomecânico com o uso de sistemas rotatórios está associado com a incidência dessas alterações dentinárias. Atualmente, o uso de um único instrumento para a instrumentação dos canais radiculares juntamente com uma cinemática reciprocante tem sido introduzido. Desse modo, o objetivo desse estudo foi avaliar a incidência de defeitos dentinários causado por três sistemas de instrumento único. Cento e quarenta raízes mesiais de molares inferiores foram selecionadas e aleatoriamente divididas em quatro grupos (n= 35 por grupo). Um grupo não sofreu intervenção e serviu como controle. As demais raízes foram preparadas pelos instrumentos reciprocantes WaveOne (Dentsply-Maillefer) e Reciproc (VDW) e por um instrumento de rotação contínua One Shape (Micro-Mega). As raízes foram seccionadas horizontalmente com auxílio de uma máquina de corte de precisão (IsoMet 1000 Precision Saw) em 03, 06 e 09 mm a partir do ápice e observadas em um estereomicroscópio (Zeiss Stemi SV6, Carl Zeiss) sob um aumento de 20×. Imagens das fatias foram gravadas e avaliadas por dois observadores cegos, previamente calibrados. As fatias foram categorizadas em: 0 - Ausência de defeitos; 1- Outros defeitos; 2- Fratura Vertical da Raiz. Os resultados obtidos foram submetidos à análise estatística com nível de significância fixado em α= 0.05. Os testes Qui-quadrado e Exato de Fisher foram utilizados para analisar e comparar as diferenças entre os grupos. O grupo controle não apresentou defeito. Todos os grupos experimentais apresentaram defeitos dentinários e foram diferentes estatisticamente do grupo controle (P < 0.05). Os grupos reciprocantes foram associados à presença de mais defeitos do que o grupo One Shape, mas não houve diferença significante entre eles (P = .115). O grupo One Shape foi o único que apresentou FVR. Os resultados obtidos nesse estudo sugerem que o preparo biomecânico com instrumentos rotatórios e/ou de reciprocidade podem causar danos na dentina radicular.
|
483 |
Avaliação das alterações morfológicas de três tipos diferentes de instrumentos endodônticos, após a instrumentação de canais radiculares, com a utilização da microscopia eletrônica de varreduraSomenzari Neto, Henrique [UNESP] 03 March 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-03-03Bitstream added on 2014-06-13T19:11:08Z : No. of bitstreams: 1
somenzarineto_h_me_arafo.pdf: 770431 bytes, checksum: ccfcddbbe84f78661018f873cf984b0d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi realizada uma análise comparativa entre três técnicas de instrumentação distintas, utilizando-se instrumentos do sistema Endo-Eze, com movimentação oscilatória; instrumentos do sistema Pow-R, com movimentação rotatória e instrumentos Tipo K manuais, com técnica de forças balanceadas. Os instrumentos foram utilizados em uma sequência técnica pré-determinada em pré-molares superiores humanos, birradiculados, por cinco vezes. Para cada técnica utilizamos quatro jogos de instrumentos novos. Os instrumentos foram fotografados com o auxílio do microscópio eletrônico de varredura quando estavam sem uso, após uma vez de uso e após cinco vezes de uso. Para cada instrumento utilizado foi atribuído um escore de acordo com o grau de deformação apresentado. A correlação numérica para cada instrumento foi submetida a uma análise estatística (Teste de Kruskal-Wallis) para podermos determinar diferenças estatísticas significantes entre esses três grupos de instrumentos endodônticos. Os resultados obtidos foram tratados estatísticamente e permitiram concluir que não houve diferenças estatisticamente significantes entre os três grupos estudados para a situação de uma vez de uso. No entanto, para as situações sem uso e cinco vezes de uso os instrumentos do Grupo I (Endo-Eze) apresentaram melhores resultados quando comparados com os Grupos II e III (Pow-R e Manual). / It was comparatively analysed 3 different instrumentation techniques upon Endo-Eze, Pow-R and manual K-file instrument deformation Upper bicuspid teeth were instrumented 5 times, and the instruments were photographed before, and after 1 and 5 times of use. For each instrument, it was stablished one specific score, that when submmited to Kruskal-Wallis test showed better results to Endo-Eze group, followed by Pow-R and Manual respectivelly.
|
484 |
Avaliação da instrumentação rotatória com limas de níquel e titânio, K3 e RaCe, em canais radiculares curvos simuladosLeonardi, Denise Piotto [UNESP] 16 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-02-16Bitstream added on 2014-06-13T19:52:07Z : No. of bitstreams: 1
leonardi_dp_me_arafo.pdf: 741813 bytes, checksum: 2517134a5a1799a4a8f6f37ddf2985b0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foram analisadas, comparativamente, a ação e a presença de deformações proporcionadas pela instrumentação com limas manuais Flexofile e dois Sistemas Rotatórios de Limas Endodônticas de Níquel e Titânio: o Sistema K3 (SDS Kerr) e o Sistema Race (FKG), sobre as paredes dos canais radiculares curvos simulados em blocos de resina. Foram utilizadasa as técnicas manual e ultra-sônica de irrigação. Após a instrumentação, os blocos de resina foram digitalizados, analisados e estabelecido escores de acordo com a qualidade do preparo biomecânico obtido em cada uma das técnicas. Concluímos que os melhores resultados foram obtidos com as duas técnicas de instrumentação rotatória associadas à irrigação manual. / It were comparatively analyzed the action and aberrations provided by the instrumentation using manual files Flexofile and two Rotary Systems of Endodontic Nickel-Titanium files, the K3 (SDS Kerr) System and the Race (FKG) System, in the curved root canal walls simulated in resin blocks, with two irrigations techniques: a manual and an ultrasonic technique. Thereafter the instrumentation, the resin blocks were digitalized, analysed and scores were set according to the preparation's quality achieved in each technique. It was ended that the best results were obtained with the two techniques of rotary instrumentation associated to the manual irrigation.
|
485 |
Avaliação de solubilidade e desintegração, alteração dimensional e resistência à compressão de cimentos endodônticosGuinesi, Adriana Simionatto [UNESP] 26 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-03-26Bitstream added on 2014-06-13T19:52:09Z : No. of bitstreams: 1
guinesi_as_me_arafo.pdf: 754134 bytes, checksum: 23c103d33c850eddf1ca5b948632482a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito do presente estudo foi avaliar os cimentos endodônticos Acroseal, AH Plus, Epiphany e Polifil (cimento endodôntico experimental), no que se refere às propriedades de solubilidade e desintegração, alteração dimensional e resistência à compressão. Os testes seguiram a Norma ISO 6876-2, de 2001 e ISO 9917-1, de 2003. Nos testes de solubilidade e desintegração foram utilizados moldes de teflon (4mm de espessura, 12mm de diâmetro interno e 2mm de parede) preenchidos com cimentos endodônticos e contendo perfuração com fio de nylon para suspensão das amostras. Os espécimes foram levados à estufa até a presa dos materiais. Em seguida, as amostras hidratadas e desidratadas tiveram sua massa mensurada imediatamente após sua retirada da estufa, e após períodos de 24h, 48h, 72h, 7, 14, 30, 60 e 90 dias. A solubilidade dos cimentos endodônticos foi identificada pela alteração da massa de cada amostra, expressa como o percentual de massa perdida em comparação à massa inicial. A desintegração foi identificada visualmente, pela observação de resíduos nos recipientes e pela turbidez da água destilada. Nos testes de alteração dimensional e resistência à compressão foram utilizados moldes de teflon (12mm de espessura e 6mm de diâmetro). Os moldes foram preenchidos com cimentos endodônticos e levados à estufa até a tomada de presa, então foram removidos dos moldes e, para os testes de alteração dimensional, suas dimensões foram medidas, no sentido longitudinal, com paquímetro digital, imediatamente após sua retirada da estufa e após períodos de 24, 48 e 72 horas, 7, 14, 30, 60 e 90 dias de armazenamento. A alteração dimensional foi identificada como a percentagem de alteração volumétrica no final de cada período, em comparação ao período inicial. / Considering all the steps of the endodontic therapy, their success depend on the root canals sealing when the professional uses an endodontic sealer that gathers physical, chemical and biological properties. The aim of this study was to evaluate the endodontic sealers: Acroseal, AH Plus, Epiphany and a castor-oil based experimental sealer (Polifil) concerning the properties of solubility and disintegration, dimensional change and compressive strength. All of these tests were supposed to follow the ISO Specification 6876-2, 2001 and ISO Specification 9917-1, 2003. To perform the solubility and disintegration tests teflon rings (4 mm thickness, 12 mm of internal diameter, and 2 mm height) filled with the endodôntico sealers were used, containing perforations that allow a nylon wire passing through it, in order to get the specimens raised up. They were storaged in the oven under 37º C up to the setting time. The specimens were hydrated and dehydrated to be weighted for 24h, 48h, 72h, 7, 14, 30, 60 and 90 days. The solubility of the endodontic sealers was identified as a percentage obtained through the difference between the last measure of weight and the initial one. The disintegration were visually identified by observating the residues and the water’s whirlwind. Teflon moulds (12 mm thickness and 6mm diameter) were used in dimensional change and compressive strength tests. They were filled with the endodontic sealers and storaged in the oven under 37º C up to the setting time. Afterwards, the moulds were removed and then, for the dimensional change test, they were measured under the longitudinal position with digital pachymeter for 24h, 48h, 72h, 7, 14, 30, 60 and 90 days. The dimensional change was identified as a percentage of the volumetrical change gotten in each time, compared with the first specimen.
|
486 |
Avaliação da eficácia das instrumentações rotatórias (Sistema Quantec LX, Pow-R, Profile e Profile Série 29) em canais radiculares curvos simuladosCamargo, José Maurício Paradella de [UNESP] 08 November 2000 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2000-11-08Bitstream added on 2014-06-13T19:25:39Z : No. of bitstreams: 1
camargo_jmp_me_arafo.pdf: 2506915 bytes, checksum: 3c82c9bacd6db2893e1c2f01ff217116 (MD5) / Foram avaliadas comparativamente as técnicas Quantec LX, Pow-R, Profile e Profile série 29, em blocos de resina com canais radiculares simulados, as deformações produzidas nas paredes côncavas e convexas, através da editoração de imagens com a utilização do programa AutoCAD. Os resultados nos permitiram concluir que o sistema que mais provocou a ampliação foi o sistema Quantec LX seguido respectivamente pelo sistema Profile série 29, sistema Profile e sistema Pow-R. Permitiu também fazer uma análise matemática de qual a quantidade e local do desgaste nos níveis 1, 3, 5, 7, 12 e 16 milímetros. / It was comparatively evaluated the Quantec LX, Pow-R, Profile and Profile series 29 techniques, utilizing resin blocks, with simulated canals. The evaluation was done with the AutoCAD program after image editoration. The results led us to conclude that, the Quantec LX system promoted the greater amplification of the root canal, folowed by Profile series 29, Profile and Pow-R systems. This kind of analysis, alowed us to concluse also, where and the quantity of wear in different levels.
|
487 |
Estudo do pH e atividade antimicrobiana sobre Enterococcus faecalis de medicação intracanal à base de hidróxido de cálcio associada ao óleo de melaleuca, clorexidina ou farnesol /Vasconcelos, Rodrigo Arruda January 2016 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Banca: Denise M Spolidorio / Banca: Flaviana Bombarda de Andrade / Resumo: Medicações intracanal (MIC) são utilizadas para complementar a desinfecção do sistema de canais radiculares. A associação de antimicrobianos ao hidróxido de cálcio visa aumentar sua ação. As MIC (Capítulo 1) hidróxido de cálcio (HC)/óleo de melaleuca (OM) 4,5%/polietilenoglicol 400 (PL), HC/OM 9%/PL, HC/CLX 0,4%/PL e HC/PL (Capítulo 2) HC/farnesol (FAR) 4,5%/PL, HC/FAR 9%/PL e HC/PL foram analisadas. O teste de contato direto sobre células planctônicas (Capítulos 1 e 2) foi realizado utilizando suspensões das MIC. O teste de contato direto das MIC sobre briofilme (Capítulo 2) foi realizado em blocos de dentina bovina (5mm x 5mm x 0,7mm) com biofilme de Enterococcus faecalis induzidos por 15 dias e contato com as suspensões das MIC por 6 horas. A efetividade antibacteriana (Capítulos 1 e 2) foi avaliada em canais radiculares de dentes de humanos extraídos. Canais radiculares de dentes unirradiculares padronizados em 15mm foram preparados até MTwo #40/.04 e contaminados com E. faecalis por 21 dias. As MIC foram mantidas no canal durante 7 dias. A primeira coleta (C1) foi realizada após período de contaminação, a segunda coleta (C2), imediatamente após a remoção das MIC e terceira coleta (C3), realizada 7 dias após a remoção das MIC. Foi realizada contagem de UFCmL-1. O pH foi avaliado após preenchimento de tubos de polietileno (Capítulos 1 e 2) com as pastas por 12 horas, 1, 3, 7, 14, 21 e 28 dias. A difusão de íons hidroxila por meio de dentina bovina (Capítulos 1 e 2) foi ava... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Intracanal medications (ICM) are used to complement desinfection of the root canal system. The association of antimicrobials to calcium hydroxide aims to improve its action. The ICM (Chapter 1) calcium hydroxide (CH)/tea tree oil (TTO) 4.5%/polyethylene glycol 400 (PL), CH/TTO 9%/PL, CH/chlorhexidine (CHX) 0.4%/PL e CH/PL (Chapter 2) CH/farnesol (FAR) 4.5%/PL, CH/FAR 9%/PL and HC/PL were analysed. Direct contact test against E. faecalis planktonic cells (Chapters 1 and 2) was performed by using suspension of ICM. Direct contact test on biofilm (Chapter 2) was performed on bovine dentin blocks (5mm x 5mm x 0.7mm) with E. faecalis biofilms induced by 15 days and contact with the suspensions of ICM for 6 hours. Antibacterial effectiveness was evaluated in root canals of extracted human teeth (Chapters 1 e 2). Standardized single-rooted teeth with 15mm were prepared up to #40/.04 MTwo and contaminated with E. faecalis for 21 days. As ICM were kept within the root canals for 7 days. The first sample (S1) was performed after contamination, S2 immediately after the ICM removal and S3 7 days after the ICM removal.It was performed UFCmL-1 count. pH was evaluated after filling the polyethylene tubes (Chapter 1 and 2) with the ICM for 12 hours, 1, 3, 7, 14, 21 and 28 days. The diffusion of hydroxyl ions through the bovine dentin (Chapters 1 and 2) was evaluated after filling root canals of bovine teeth after 1, 3, 7, 14, 21, 28 and 60 days. Data was statistically analyzed using ANOVA an... (Complete abstract click electronic access below) / Mestre
|
488 |
Citotoxicidade do ácido peracético : avaliação metabólica, estrutural e de morte em fibroblastos L929 /Viola, Kennia Scapin. January 2016 (has links)
Orientador: Gisele Faria / Banca: Andrea Soares da Costa Fuentes / Banca: Mário Tanomaru-Filho / Resumo: A solução de ácido peracético (AP) vem sendo citada na literatura odontológica como uma possível solução irrigadora de canais radiculares. Ele apresenta a vantagem de reunir em um só produto atividade antibacteriana e capacidade de remoção de tecido orgânico e de smear layer. Para a seleção da solução irrigadora de canais radiculares deve-se levar em consideração não somente os seus benefícios terapêuticos, mas também os possíveis efeitos citotóxicos, uma vez que ela pode entrar em contato com os tecidos periapicais. O objetivo deste estudo foi investigar a citotoxicidade e o mecanismo de agressão celular do AP em comparação com o hipoclorito de sódio (NaOCl) sobre fibroblastos L929 por meio de avaliação metabólica, estrutural, ultraestrutural e de morte celular (necrose e/ou apoptose). As células foram incubadas com diferentes concentrações do AP a 1% e do NaOCl a 2,5%, por 10 minutos. Após este período, foram avaliados o metabolismo celular por meio do ensaio do metiltetrazólio (MTT), a morfologia externa das células em microscópio eletrônico de varredura, a ultraestrutura em microscópio eletrônico de transmissão, o citoesqueleto por meio de marcação para actina e α- tubulina, o tipo de morte celular (necrose ou apoptose) por citometria de fluxo. Os resultados foram analisados empregando ANOVA de dois fatores e pós-teste de Bonferroni (α=0.05). Observou-se que o AP apresentou maior citotoxicidade do que o NaOCl. As alterações no metabolismo, na viabilidade, nos filamentos d... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The solution peracetic acid (PA) has been reported in the dental literature as a possible root canal irrigating solution. It has the advantage of attending together in one product antibacterial activity and ability to remove of organic tissue and smear layer. For selection of root canal irrigating solution it should take into account not only its therapeutic benefits, but also the possible cytotoxic effects, since it can contact the periapical tissues. The aim of this study was to evaluate the aggression mechanism of 1% AP compared with 2.5% sodium hypochlorite (NaOCl) on L929 fibroblasts through metabolic evaluation, structural, ultrastructural and cell death (necrosis and / or apoptosis). The cells were incubated with different dilutions of the 1% AP and 2.5% NaOCl for 10 minutes. After this period, it was evaluated the cell metabolism by methyl tetrazolium (MTT) assay, the cell external morphology in scanning electron microscope, the ultrastructure in transmission electron microscope, the cytoskeleton by marking to actin and α-tubulin, the type of cell death (necrosis or apoptosis) by flow cytometry. The results were analyzed using two-way ANOVA and Bonferroni post-test (α = 0.05). It was observed that the AP showed higher cytotoxicity than NaOCl. Changes in metabolism, viability, in actin filaments and microtubules, surface morphology and ultraestrtura cells were observed at lower dilutions AP when compared to NaOCl. Cell death caused for both the AP and for NaOCl occurre... (Complete abstract click electronic access below) / Mestre
|
489 |
Avaliação da instrumentação rotatória com limas de níquel e titânio, K3 e RaCe, em canais radiculares curvos simulados /Leonardi, Denise Piotto. January 2004 (has links)
Orientador: Roberto Miranda Esberard / Banca: Renato de Toledo Leonardo / Banca: Giulio Gavini / Resumo: Foram analisadas, comparativamente, a ação e a presença de deformações proporcionadas pela instrumentação com limas manuais Flexofile e dois Sistemas Rotatórios de Limas Endodônticas de Níquel e Titânio: o Sistema K3 (SDS Kerr) e o Sistema Race (FKG), sobre as paredes dos canais radiculares curvos simulados em blocos de resina. Foram utilizadasa as técnicas manual e ultra-sônica de irrigação. Após a instrumentação, os blocos de resina foram digitalizados, analisados e estabelecido escores de acordo com a qualidade do preparo biomecânico obtido em cada uma das técnicas. Concluímos que os melhores resultados foram obtidos com as duas técnicas de instrumentação rotatória associadas à irrigação manual. / Abstract: It were comparatively analyzed the action and aberrations provided by the instrumentation using manual files Flexofile and two Rotary Systems of Endodontic Nickel-Titanium files, the K3 (SDS Kerr) System and the Race (FKG) System, in the curved root canal walls simulated in resin blocks, with two irrigations techniques: a manual and an ultrasonic technique. Thereafter the instrumentation, the resin blocks were digitalized, analysed and scores were set according to the preparation's quality achieved in each technique. It was ended that the best results were obtained with the two techniques of rotary instrumentation associated to the manual irrigation. / Mestre
|
490 |
Comparação "in vitro" da adesão de diferentes cimentos endodônticos à dentina radicular e aos componentes sólidos da obturação /Barbizam, João Vicente Baroni. January 2006 (has links)
Orientador: Mário Tanomaru Filho / Banca: Marco Antônio Húngaro Duarte / Banca: Manoel Damião de Souza Neto / Banca: Luis Geraldo Vaz / Banca: Idomeo Bonetti Filho / Resumo: O objetivo desse estudo é avaliar "in vitro", por meio dos testes de push-out e tração, a adesão de diferentes cimentos endodônticos à dentina e aos componentes sólidos da obturação, guta-percha e resilon. Sessenta dentes humanos uniradiculares tiveram suas coroas removidas e foram divididos em três gupos de vinte dentes. Cada grupo foi instrumentado pela técnica rotatória até uma lima tipo Profile 40.04 e alargados com uma broca de preparo de pino com 1,5 mm de diâmetro, sob irrigação com hipoclorito de sódio 2,5% (NaOCl) seguido de irrigação final com EDTA 17%; gel de clorexidina 2%(CHX) alternado com soro fisiológico e seguido por EDTA 17% ou apenas com soro fisiológico, como controle. A seguir, foram obturados com os cimentos AH 26, Endo Fill, Endo Rez e Epiphany. Após 48 horas de incubação a 37 graus Celsius e 100% de umidade, os dentes foram cortados tranversalmente em discos de 2 mm de espessura. As amostras foram submetidas à força de compressão pelo teste de push-out. Para o teste de tração, discos de guta-percha e resilon foram criados e os cimentos AH 26, Endo Fill, Endo Rez e Epiphany foram colocados em contato com o material sólido da obturação por meio de anéis metálicos contendo os cimentos em seu interor. Após incubação as amostras foram submetidas ao teste de tração. Ambos os testes foram realizados em máquina de ensaios (1mm/min) e os resultados expressos em Mpa. O teste Anova e Newman-Keuls evidenciaram que cimento Epiphany apresentou maior adesão à dentina no teste de push-out, seguido pelos cimentos Endo Rez e AH 26 que foram semelhantes entre si e, por último o cimento Endo Fill. O uso da CHX aumentou a adesão à dentina de todos os cimentos testados. No teste de tração aos componentes sólidos, o cimento AH 26 mostrou ter uma maior adesão que os demais cimentos, que foram semelhantes entre si. / Abstract: The aim of this in vitro study was to evaluate the bond strength of different root canal sealers to dentin and to the filling core material, using push-out and tensile tests. Sixty extracted single-rooted human teeth were divided into three groups and evenly instrumented with the crown-down technique up to a file #55 followed by a root canal enlargement using a 1,5 mm diameter post drill. Teeth were prepared under irrigation with 2.5% NaOCl + EDTA 17 %, 2% CHX associated to a saline solution + EDTA 17% or just saline solution, as control. All teeth were completely filled with AH 26, Endo Rez, Endo Fill and Epiphany sealers. After 48 hours of storage in 100% humidity at 37°C, all samples were sectioned transversally into 2mm thickness disks and the push-out tests were performed. For the tensile tests, gutta-percha and resilon disks were created and metallic rings with the sealers were positioned over the core material disks, in the same time/temperature conditions. Both push-out and tensile tests were performed using the universal testing machine (1 mm/min) and the maximum load at failure expressed in MPa. Two-way ANOVA and Newman-Keuls tests showed that Ephipany sealant presented the highest bond strength to dentin followed by Endo REZ and AH 26 that were similar to each other and Endo Fill with the lowest values of bonding to dentin. 2% CHX irrigation increased the bonding strength of all sealers to dentin. Tensile tests to the filling core materials showed that AH 26 presented the highest values of bonding. No statistical differences were found between the other sealers. / Doutor
|
Page generated in 0.0546 seconds