• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • Tagged with
  • 20
  • 20
  • 20
  • 8
  • 7
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e avaliação biomecânica da resistência à flexão de um novo modelo de osteossíntese em fêmur: pinos intramedulares múltiplos bloqueados / Development and biomechanical evaluation of flexural strength of a new type of osteosynthesis in femoral: multiple locked intramedullary pins

Caquías, Daniela Fabiana Izquierdo 30 June 2010 (has links)
Na atualidade, vários são os métodos de osteossíntese utilizados na reparação de fraturas de fêmur em cães, porém alguns apresentam complicações na técnica, e outros não encontram-se disponíveis na atividade profissional diária de alguns médicos veterinários da América Latina. O presente trabalho teve como objetivo desenvolver um novo modelo simples de osteossíntese, baseado na utilização de pinos de Steinmann e Schanz denominado pinos intramedulares múltiplos bloqueados (PIMB), e testar biomecanicamente a resistência as forças de flexão em comparação com a técnica de pino intramedular único (PIU). Para tanto foram utilizados fêmures bilaterais de oito cadáveres de cães com peso entre 15 a 25 quilos que foram divididos em dois grupos, o primeiro grupo composto por oito fêmures utilizou os pinos intramedulares múltiplos bloqueados e o segundo grupo composto por oito fêmures utilizou pino intramedular único, ocupando entre 40 - 42 % do canal medular como controle do Grupo 1. Os dois grupos de fêmures foram submetidos a ensaios não destrutivos para avaliar a resistência as forças de flexão, com forças entre 0 e 50 Kg, e velocidade de deslocamento de 5mm/minuto, num dispositivo de quatro pontos. Os resultados encontrados nas condições apresentadas neste estudo mostraram que a técnica de pinos intramedulares múltiplos bloqueados apresenta uma menor resistência as forças de flexão comparada com a técnica de pino intramedular único / Currently, there are several methods of fixation used in the repair of femoral fractures in dogs, but some show complications in the technique, and others are not available daily in the professional activity of some veterinarians from Latin America. This study aimed the development of a new, simple model for bone fixation, based on the use of Steinmann and threaded pins, used as multiple locked intramedullary pins (MLIP), and biomechanically test the implants resistance to bending forces. Therefore, we used bilateral femurs of eight cadaveric dogs weighing between 15-25 kg, divided into two groups; in the first group multiple locked intramedullary pins were used in eight femurs, and in the second group, the control group, we used a single intramedullary pin (SIP) occupying between 40-42% of the intramedullary canal, of eight femurs. Both groups were subjected, in a four point device, to nondestructive testing to evaluate the resistance to flexion forces, with forces varying between 0 and 50 kg, and a speed of 5mm/minute. The results under the conditions presented in this study showed that technique locked multiple pins has a lower resistance to bending forces compared with the technique of single intramedullary pin.
2

Influência dos corticosteróides nas propriedades biomecânicas da traquéia de coelhas albinas / The effects of corticosteroids biomechanical properties in trachea of albinos female rabbits

Silva, Irene Raimundo dos Santos 27 January 2003 (has links)
Foram estudados os efeitos da metilprednisolona na traquéia de coelhas albinas adultas da raça Nova Zelândia. O objetivo deste estudo foi investigar os efeitos potenciais desta substância nas propriedades biomecânicas da traquéia de coelhas por meio de ensaio de tração axial. Os animais foram divididos em dois grupos. Dez coelhas do grupo controle receberam por via subcutânea 2 mg/Kg/dia de metilprednisolona diluída em solução salina. As dez coelhas do grupo controle receberam também de modo subcutâneo volumes proporcionais de solução salina. Após 21 dias, os animais foram sacrificados e suas traquéias submetidas a ensaio de tração e estudo histopatológico. Os animais do grupo experimental apresentaram peso significantemente inferior ao do grupo controle no final do tratamento (C = 3996 ± 314 g x E = 3555 ± 373 g). Os grupos não diferiram do ponto de vista estatístico quanto as seguintes variáveis: carga no limite de proporcionalidade (C = 8,94 ± 1,68 N x E = 8,93 ± 1,52 N); carga máxima (C = 9,12 ± 2,2 N x E = 9,57 ± 1,90 N); alongamento no limite de proporcionalidade (C = (683 ± 2,08) x '10 POT.-3' m x E = (6,05 ± 1,50) x '10 POT.-3' m); alongamento máximo (C = (7,44 ± 2,60) x '10 POT.-3' m x E = (6,85 ± 1,55) x '10 POT.-3' m); energia absorvida na fase elástica (C = (28,70 ± 14,43) x '10 POT.-3' J x E = (27,75 ± 11,06) x '10 POT.-3' J); rigidez (C = (1,08 ± 0,41) x '10 POT.-3' N/m x E = (1,2 ± 0,37) x '10 POT.-3' N/m). Concluiu-se ao término deste estudo que não houve alterações morfológicas e biomecânicas das traquéias estudadas, no entanto, os animais do grupo experimental sofreram significante emagrecimento ao final do tratamento, quando comparado ao grupo experimental / The effects of methilprednisolona in the adult’s trachea albinos female rabbits were studied. The goal of this study was examine the potential effects of this armorial traction. The animals were divided in two groups. Ten female rabbits of control group received by way of subcutaneous 2mg/kg/day of salt bed diluted solution. These ten female rabbits of the control group also received by way of subcutaneous proportional volumes of salt bed solution. After 21 days, the animals were sacrificed and their trachea were subjected to traction tests and anatomical pathological studies. Animals of the experimental group presented inferior weight significant from the control group in the end of the treatment (C = 8,94 ± 314g X E = 3555 ± 373g). The groups didn’t differ from the statistic point of view as regards of the following variables: limit load of proportionality (C = 8,94 ± 1,68 N X E = 8,93 ± 1,52 N); maxim load (C = 9,12 ± 2,2 N X E = 9,57 ± 1,90 N); stretch out on the limit of proportionality (C = (683 ± 2,08) x '10 POT.-3' m X E = (6,05 ± 1,50) x '10 POT.-3' m); maxim stretch out (C = (7,44 ± 2,60) x '10 POT.-3' J X E = (6,85 ± 1,55) x '10 POT.-3' J); absorbed energy in the elastic phase (C = 28,70 ± 14,43) x '10 POT.-3' m J X E = (27,75 ± 11,06) x '10 POT.-3' J); rigidity (C = 1,08 ± 0,41) x '10 POT.-3' N/m X E = (1,2 + 0,37) x '10 POT.-3' N/m). It was concluded in the end of the treatment that there weren’t any morphological and biomechanical alterations of the trachea studied, although, the animals of the experimental group suffered a significant slimming in the end of the treatment when compared with the experimental group
3

Influência dos corticosteróides nas propriedades biomecânicas da traquéia de coelhas albinas / The effects of corticosteroids biomechanical properties in trachea of albinos female rabbits

Irene Raimundo dos Santos Silva 27 January 2003 (has links)
Foram estudados os efeitos da metilprednisolona na traquéia de coelhas albinas adultas da raça Nova Zelândia. O objetivo deste estudo foi investigar os efeitos potenciais desta substância nas propriedades biomecânicas da traquéia de coelhas por meio de ensaio de tração axial. Os animais foram divididos em dois grupos. Dez coelhas do grupo controle receberam por via subcutânea 2 mg/Kg/dia de metilprednisolona diluída em solução salina. As dez coelhas do grupo controle receberam também de modo subcutâneo volumes proporcionais de solução salina. Após 21 dias, os animais foram sacrificados e suas traquéias submetidas a ensaio de tração e estudo histopatológico. Os animais do grupo experimental apresentaram peso significantemente inferior ao do grupo controle no final do tratamento (C = 3996 ± 314 g x E = 3555 ± 373 g). Os grupos não diferiram do ponto de vista estatístico quanto as seguintes variáveis: carga no limite de proporcionalidade (C = 8,94 ± 1,68 N x E = 8,93 ± 1,52 N); carga máxima (C = 9,12 ± 2,2 N x E = 9,57 ± 1,90 N); alongamento no limite de proporcionalidade (C = (683 ± 2,08) x '10 POT.-3' m x E = (6,05 ± 1,50) x '10 POT.-3' m); alongamento máximo (C = (7,44 ± 2,60) x '10 POT.-3' m x E = (6,85 ± 1,55) x '10 POT.-3' m); energia absorvida na fase elástica (C = (28,70 ± 14,43) x '10 POT.-3' J x E = (27,75 ± 11,06) x '10 POT.-3' J); rigidez (C = (1,08 ± 0,41) x '10 POT.-3' N/m x E = (1,2 ± 0,37) x '10 POT.-3' N/m). Concluiu-se ao término deste estudo que não houve alterações morfológicas e biomecânicas das traquéias estudadas, no entanto, os animais do grupo experimental sofreram significante emagrecimento ao final do tratamento, quando comparado ao grupo experimental / The effects of methilprednisolona in the adult’s trachea albinos female rabbits were studied. The goal of this study was examine the potential effects of this armorial traction. The animals were divided in two groups. Ten female rabbits of control group received by way of subcutaneous 2mg/kg/day of salt bed diluted solution. These ten female rabbits of the control group also received by way of subcutaneous proportional volumes of salt bed solution. After 21 days, the animals were sacrificed and their trachea were subjected to traction tests and anatomical pathological studies. Animals of the experimental group presented inferior weight significant from the control group in the end of the treatment (C = 8,94 ± 314g X E = 3555 ± 373g). The groups didn’t differ from the statistic point of view as regards of the following variables: limit load of proportionality (C = 8,94 ± 1,68 N X E = 8,93 ± 1,52 N); maxim load (C = 9,12 ± 2,2 N X E = 9,57 ± 1,90 N); stretch out on the limit of proportionality (C = (683 ± 2,08) x '10 POT.-3' m X E = (6,05 ± 1,50) x '10 POT.-3' m); maxim stretch out (C = (7,44 ± 2,60) x '10 POT.-3' J X E = (6,85 ± 1,55) x '10 POT.-3' J); absorbed energy in the elastic phase (C = 28,70 ± 14,43) x '10 POT.-3' m J X E = (27,75 ± 11,06) x '10 POT.-3' J); rigidity (C = 1,08 ± 0,41) x '10 POT.-3' N/m X E = (1,2 + 0,37) x '10 POT.-3' N/m). It was concluded in the end of the treatment that there weren’t any morphological and biomechanical alterations of the trachea studied, although, the animals of the experimental group suffered a significant slimming in the end of the treatment when compared with the experimental group
4

Desenvolvimento e avaliação biomecânica da resistência à flexão de um novo modelo de osteossíntese em fêmur: pinos intramedulares múltiplos bloqueados / Development and biomechanical evaluation of flexural strength of a new type of osteosynthesis in femoral: multiple locked intramedullary pins

Daniela Fabiana Izquierdo Caquías 30 June 2010 (has links)
Na atualidade, vários são os métodos de osteossíntese utilizados na reparação de fraturas de fêmur em cães, porém alguns apresentam complicações na técnica, e outros não encontram-se disponíveis na atividade profissional diária de alguns médicos veterinários da América Latina. O presente trabalho teve como objetivo desenvolver um novo modelo simples de osteossíntese, baseado na utilização de pinos de Steinmann e Schanz denominado pinos intramedulares múltiplos bloqueados (PIMB), e testar biomecanicamente a resistência as forças de flexão em comparação com a técnica de pino intramedular único (PIU). Para tanto foram utilizados fêmures bilaterais de oito cadáveres de cães com peso entre 15 a 25 quilos que foram divididos em dois grupos, o primeiro grupo composto por oito fêmures utilizou os pinos intramedulares múltiplos bloqueados e o segundo grupo composto por oito fêmures utilizou pino intramedular único, ocupando entre 40 - 42 % do canal medular como controle do Grupo 1. Os dois grupos de fêmures foram submetidos a ensaios não destrutivos para avaliar a resistência as forças de flexão, com forças entre 0 e 50 Kg, e velocidade de deslocamento de 5mm/minuto, num dispositivo de quatro pontos. Os resultados encontrados nas condições apresentadas neste estudo mostraram que a técnica de pinos intramedulares múltiplos bloqueados apresenta uma menor resistência as forças de flexão comparada com a técnica de pino intramedular único / Currently, there are several methods of fixation used in the repair of femoral fractures in dogs, but some show complications in the technique, and others are not available daily in the professional activity of some veterinarians from Latin America. This study aimed the development of a new, simple model for bone fixation, based on the use of Steinmann and threaded pins, used as multiple locked intramedullary pins (MLIP), and biomechanically test the implants resistance to bending forces. Therefore, we used bilateral femurs of eight cadaveric dogs weighing between 15-25 kg, divided into two groups; in the first group multiple locked intramedullary pins were used in eight femurs, and in the second group, the control group, we used a single intramedullary pin (SIP) occupying between 40-42% of the intramedullary canal, of eight femurs. Both groups were subjected, in a four point device, to nondestructive testing to evaluate the resistance to flexion forces, with forces varying between 0 and 50 kg, and a speed of 5mm/minute. The results under the conditions presented in this study showed that technique locked multiple pins has a lower resistance to bending forces compared with the technique of single intramedullary pin.
5

Desenvolvimento de máquina de movimentos cíclicos para testes biomecânicos / Development of machine of cyclic movements for biomechanical tests

Marinheiro, Carlos Alberto 10 February 2003 (has links)
O ser humano locomove-se utilizando-se do complexo sistema neuro-músculo-esquelético, o que lhe confere qualidade de vida. Partes do sistema esquelético são passíveis de tratamento ou mesmo de substituição pelo emprego de materiais estranhos ao corpo humano mas que provocam pequena reação biológica e necessitam ser dimensionados de modo a suportar toda tensão resultante do movimento humano. O objetivo deste trabalho foi desenvolver uma máquina de ensaio cíclico para testes biomecânicos, de implantes utilizados nas cirurgias de reconstrução ósteo-articular, utilizando tecnologia nacional. A máquina possui um sistema de acionamento por meio de um motor trifásico de 2 HP, 1800 rpm; um sistema de transmissão de cargas cíclicas utilizando um eixo excêntrico, que aciona um pistão, que promove o movimento de duas alavancas que transmitem a carga para os componentes a serem ensaiados. Há um inversor de freqüência para controle do número de ciclos do motor, um reservatório de soro fisiológico com um sistema que mantém o soro aquecido entre 36 e 38 ºC, e uma bomba hidráulica submersa que mantém o soro em constante movimentação. Foi feito um teste cíclico de fadiga de componente femoral de artroplastia de quadril, com torção, seguindo determinações das normas ISO 7206/89, parte 4 e ASTM F 1612/95, e utilizada para o teste a Prótese Femoral Cimentada Modelo Alpha ® da empresa Baumer ®, haste polida de 150 mm e off-set de 37,5 mm. Também foi feito um ensaio para verificação de trincas seguindo determinações da Norma ABNT NBR ISO 9583/1997. Durante as 139 horas previstas para o teste de fadiga do componente femoral, a máquina de ensaio não apresentou problemas mecânicos, demonstrando eficiência e o êxito na confecção de uma máquina de ensaios cíclicos para testes biomecânicos / The human being locomotes using the complex neuro-muscle-skeletal system, what confers him life quality. Parts of the skeletal system can submit to treatment or even to the substitution for the employment of strange materials to the human body but that provoke small biological reaction and they need to be projected in way to support every resulting tension of the human movement. The objective of this work was to develop a machine of cyclic trial for biomechanical tests using national technology. The machine has an activation system by means of a triphasic motor of 2 HP, 1800 rpm; a system of transmission of cyclic loads using an eccentric axis, that activates a piston, that promotes the movement of two levers that transmit the load for the components at be tested. There is a frequency inverter for control of the number of cycles of the motor, a reservoir of physiologic serum with a system that maintains the serum heated up to 36-38 ºC, and a submerged hydraulic bomb that maintains the serum in constant movement. It was made a cyclic test of fatigue of femoral component of hip arthroplasty, with torsion, following determinations of the norms ISO 7206/89, part 4 and ASTM F 1612/95, and used for the test the Prosthesis Femoral Cemented Model Alpha ® of the company Baumer ®, polished stem of 150 mm and off-set of 37,5 mm. It was also made a trial for verification of cracks following determinations of the norm ABNT NBR ISO 9583/1997. During the 139 hours foreseen for the test of fatigue of the femoral component, the trial machine didn’t present mechanical problems, demonstrating efficiency and the success in the production of a machine of cyclic trials for biomechanical tests
6

Artrodese da articulação interfalangeana proximal de equinos: avaliação biomecânica comparativa da técnica com placa de compressão dinâmica de 4,5mm e três orifícios, com dois parafusos transarticulares oblíquos de 5,5mm e técnica com placa \"Y\" de compressão bloqueada de 5,0mm e sete orifícios / Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of one 3-Hole 4.5-mm Narrow Dynamic Compression Plate with two 5.5mm oblique cortex screws technique and one 7-Hole 5.0mm \"Y\" locking compression plate technique

Latorre, Carlos Adolfo Salazar 25 June 2013 (has links)
As claudicações são a principal causa de encaminhamento de equinos aos médicos veterinários e uma das maiores causas de encaminhamento destes animais aos hospitais de referência; sendo as fraturas, especialmente aquelas de ossos longos e articulares, as que têm menor índice de sucesso devido ao prognóstico reservado e alto custo do tratamento; entendendo como sucesso o retorno do animal à função ou manutenção da qualidade de vida. A articulação interfalangeana proximal (AIP) dos equinos é clinicamente importante devido à apresentação frequente de claudicação, com lesões que comprometem a vida esportiva e função do equino. O objetivo desta pesquisa foi comparar biomecanicamente as características de duas técnicas de artrodese da AIP em equinos, utilizando-se placa de compressão dinâmica (DCP) de 4.5mm e três orifícios em combinação com dois parafusos corticais transarticulares de 5.5mm oblíquos inseridos pela técnica de tração (lag screw) e placa em "Y\" de compressão bloqueada (LCP) de 5,0mm e sete orifícios, com parafusos bloquados unicorticais e um parafuso cortical de 4.5mm oblíquo transarticular inserido no orifício central da placa, pela técnica de parafuso de tração. Foram utilizadas doze peças anatômicas de membros anteriores de equinos, das quais foi isolada a porção distal do membro desde a primeira falange até o casco. Uma vez preparadas as peças, cada par foi sorteado randomicamente para cada um dos dois grupos. Os modelos experimentais foram submetidos a ensaios biomecânicos de compressão axial em ciclo único até a sua falha. O tipo de falha ocorrida na placa, nos parafusos ou nos ossos foi avaliado, assim como a força à qual ocorreram estas falhas. Não houve diferença estatística significativa entre os grupos DCP e Y-LCP, nas variáveis rigidez e força máxima, quando submetidas a compressão axial até sua falha. Mesmo não havendo diferença entre as duas técnicas cirúrgicas na variável rigidez, a técnica Y-LCP possibilitou um procedimento menos invasivo e com menor tempo cirúrgico. Conclui-se que, as propriedades biomecânicas das duas técnicas de fixação (DCP e Y-LCP) são semelhantes nas condições testadas. / Lameness is the main cause of sport horses\' owners consulting equine veterinarians and one of the highest cause to send these animals to the reference hospitals. Long bones and joint fractures have the lesser rate of success, consequence of the hight cost of the treatment and poor prognosis. Understanding as success the return of the horse to previous athletic performance or at least to have useful life. The proximal interphalangeal joint (PIPJ) is clinically important because the injuries that involve it may threaten the horses sport life or its usefulness. The objective of this study was to compare the biomechanical properties of two PIPJ arthrodesis techniques using 4.5mm dynamic compression plate (DCP) in conjunction with two oblique abaxial transarticular 5.5mm cortical screws inserted in lag fashion and 5.0mm Y locking compression plate (Y-LCP) with unicortical locking screws and one axial transarticular 4.5mm cortex screw inserted in lag fashion through the midle plate hole. It was used twelve cadaveric adult equine forelimbs from the first phalanx to the foot. After full-limb preparations, each forelimb pair was randomly assigned to one of two treatment groups. Constructs were submited to axial compression single cycle to failure biomechanical testing. The failure of the screws, plate or bone, and the force at wich it happened was evaluated. There were no significant differences in construct stiffness or max force when loaded to failure, between the DCP and Y-LCP treatment groups. Even though there was no construct stiffness diffrences between the two techniques, the Y-LCP technique provided the possibility of a less invasive procedure with a shorter surgical time. In conclusion, the biomechanical properties of both fixation techniques (DCP and Y-LCP) are equivalent under the test conditions used.
7

Avaliação da resistência mecânica à compressão axial da poliuretana de mamona e quitosana associada a cimento de fosfato de cálcio no preenchimento de falhas ósseas do terceiro metacarpiano de equinos / Mechanical evaluation of strength of ricinus communis polyurethane and chitosan with calcium phosphate cement on filling of bone gap in equine third metacarpal bone

Moreira, Rodrigo Crispim 30 May 2014 (has links)
Os equinos são animais que, quando adultos, apresentam elevado peso corpóreo e ossos bastante resistentes para sustentar esse peso. Dessa forma, para que ocorra fratura nos ossos do cavalo é necessário um trauma de elevada energia resultando em fraturas cominutivas, que podem formar falhas ósseas impedindo o contato entre os fragmentos ósseos, o que compromete a estabilidade e resistência da osteossíntese. Devido à complexidade desse tipo de fraturas e aos implantes disponíveis apresentarem baixa resistência para o uso nessa espécie e devido a seu comportamento, o tratamento de fraturas em equinos apresenta baixos índices de sucesso. Dessa maneira, o uso de um material osteocondutor com resistência mecânica para o preenchimento dessas falhas poderia elevar a resistência da osteossíntese, levando a melhores índices de sucesso na correção dessas fraturas. O presente estudo teve como objetivo a avaliação biomecânica em laboratório de dois biomateriais substitutos ósseos no preenchimento de falha óssea. Para isso foram utilizados 30 ossos terceiro metacarpiano de equinos que foram submetidos a osteossíntese com placa LCP em sua face dorsal e criada uma falha óssea transversal completa de um centímetro na diáfise média. Dez dessas peças foram submetidas a ensaios biomecânicos não destrutivos até a carga de 1000N, onde foram avaliadas a rigidez, as deformações da peça inteira, da placa e do osso individualmente em diferentes regiões. As outras 20 dessas peças foram submetidas a ensaios destrutivos, onde foram avaliadas a carga e deformação suportada no limite elástico e no ponto de ruptura. Dessa forma, pôde-se observar que houve aumento na rigidez de 699,39N/mm para 2905,38N/mm e 4274,93N/mm devido ao preenchimento da falha com poliuretana de mamona e quitosana, respectivamente. A peça inteira teve sua deformação diminuída de 1,73mm para 0,5mm e 0,35 com carga de 1000N, devido ao preenchimento da falha com poliuretana de mamona e quitosana, respectivamente. A placa teve sua deformação diminuída de 2260,64µd para 320,25µd pelo preenchimento da falha com poliuretana de mamona e para 89,88µd com o preenchimento com quitosana durante a aplicação de 1000N. O osso próximo à falha sofreu maiores deformações tanto com poliuretana de mamona quanto com quitosana, contudo não apresentou maiores deformações em região distante da falha. A peça inteira teve aumento da carga suportada em seu limite elástico de 1008N para 8804N apenas com o preenchimento da falha com quitosana. A peça inteira teve sua deformação diminuída de 1,64mm para 1,26 no limite elástico apenas devido ao preenchimento da falha poliuretana de mamona. A peça inteira teve aumento da força suportada no momento de ruptura de 1660N para 15187N e 11012N com o preenchimento da falha com poliuretana de mamona e quitosana, respectivamente. A peça inteira teve sua deformação máxima no ponto de ruptura diminuída de 5,4mm para 2,16mm apenas com o preenchimento da falha com quitosana. / Adult horses are heavy animals equipped with bones strong enough to support their body weight. High energy trauma is required to produce comminuted fractures, where bone loss may prevent proper fracture reduction and compromise osteosynthesis resistance and stability. In horses, aside from behavioural issues, low success rates associated with comminuted fracture resolution may be due to the complexity of such fractures or the low resistance of bone implants. Therefore, osteoconductive biomaterials with good mechanical resistance would potentially benefit treatment outcomes. This ex vivo study evaluated the biomechanical behaviour of two bone surrogate biomaterials in experimental third metacarpal fractures in horses. Thirty equine third metacarpal bone specimens were submitted to dorsal LCP (locking compression plate) osteosynthesis following creation of a transverse 1 cm wide middiaphiseal defect. Defects were filled either with Ricinus communis polyurethane or calcium phosphate cement-chitosan composite. Ten specimens were submitted to non-destructive biomechanical testing under 1000N maximum load; construct stiffness, construct deformation and isolated deformation of LCP and third metacarpal bone in different regions were evaluated. The remaining 20 specimens were submitted to destructive biomechanical testing; maximum load and deformation within the elastic limit, and to failure were documented. Bone defect repair with RCP or CPC-chitosan composite increased construct stiffness from 699,39N/mm to 2905.38N/mm and 4274.93N/mm and decreased construct deformation under 1000N from 1.73mm to 0,5mm and 0.35 respectively. LCP deformation under 1000N decreased from 2260.64d to 320.25µd and from 2260.64µd to 89.88d following filling of the bone defect with RCP or CPC-chitosan composite respectively. Bone deformation around the defect increased following treatment with RCP or CPC-chitosan composite. However bone deformation away from the defect remained unchanged. Maximum load within the elastic limit increased from 1008N to 8804N when the experimental defect was filled with chitosan composite. Conversely, construct deformation within the elastic limit decreased from 1.64mm to 1.26mm following treatment with RCP. Maximum load to construct failure increased from 1660N to 15187N and 11012N following bone defect repair with RCP or calcium phosphate cement-chitosan composite respectively. However, construct maximum deformation decreased from 5.4mm to 2.16mm when calcium phosphate cement-chitosan composite was used.
8

Desenvolvimento de máquina de movimentos cíclicos para testes biomecânicos / Development of machine of cyclic movements for biomechanical tests

Carlos Alberto Marinheiro 10 February 2003 (has links)
O ser humano locomove-se utilizando-se do complexo sistema neuro-músculo-esquelético, o que lhe confere qualidade de vida. Partes do sistema esquelético são passíveis de tratamento ou mesmo de substituição pelo emprego de materiais estranhos ao corpo humano mas que provocam pequena reação biológica e necessitam ser dimensionados de modo a suportar toda tensão resultante do movimento humano. O objetivo deste trabalho foi desenvolver uma máquina de ensaio cíclico para testes biomecânicos, de implantes utilizados nas cirurgias de reconstrução ósteo-articular, utilizando tecnologia nacional. A máquina possui um sistema de acionamento por meio de um motor trifásico de 2 HP, 1800 rpm; um sistema de transmissão de cargas cíclicas utilizando um eixo excêntrico, que aciona um pistão, que promove o movimento de duas alavancas que transmitem a carga para os componentes a serem ensaiados. Há um inversor de freqüência para controle do número de ciclos do motor, um reservatório de soro fisiológico com um sistema que mantém o soro aquecido entre 36 e 38 ºC, e uma bomba hidráulica submersa que mantém o soro em constante movimentação. Foi feito um teste cíclico de fadiga de componente femoral de artroplastia de quadril, com torção, seguindo determinações das normas ISO 7206/89, parte 4 e ASTM F 1612/95, e utilizada para o teste a Prótese Femoral Cimentada Modelo Alpha ® da empresa Baumer ®, haste polida de 150 mm e off-set de 37,5 mm. Também foi feito um ensaio para verificação de trincas seguindo determinações da Norma ABNT NBR ISO 9583/1997. Durante as 139 horas previstas para o teste de fadiga do componente femoral, a máquina de ensaio não apresentou problemas mecânicos, demonstrando eficiência e o êxito na confecção de uma máquina de ensaios cíclicos para testes biomecânicos / The human being locomotes using the complex neuro-muscle-skeletal system, what confers him life quality. Parts of the skeletal system can submit to treatment or even to the substitution for the employment of strange materials to the human body but that provoke small biological reaction and they need to be projected in way to support every resulting tension of the human movement. The objective of this work was to develop a machine of cyclic trial for biomechanical tests using national technology. The machine has an activation system by means of a triphasic motor of 2 HP, 1800 rpm; a system of transmission of cyclic loads using an eccentric axis, that activates a piston, that promotes the movement of two levers that transmit the load for the components at be tested. There is a frequency inverter for control of the number of cycles of the motor, a reservoir of physiologic serum with a system that maintains the serum heated up to 36-38 ºC, and a submerged hydraulic bomb that maintains the serum in constant movement. It was made a cyclic test of fatigue of femoral component of hip arthroplasty, with torsion, following determinations of the norms ISO 7206/89, part 4 and ASTM F 1612/95, and used for the test the Prosthesis Femoral Cemented Model Alpha ® of the company Baumer ®, polished stem of 150 mm and off-set of 37,5 mm. It was also made a trial for verification of cracks following determinations of the norm ABNT NBR ISO 9583/1997. During the 139 hours foreseen for the test of fatigue of the femoral component, the trial machine didn’t present mechanical problems, demonstrating efficiency and the success in the production of a machine of cyclic trials for biomechanical tests
9

Artrodese da articulação interfalangeana proximal de equinos: avaliação biomecânica comparativa da técnica com placa de compressão dinâmica de 4,5mm e três orifícios, com dois parafusos transarticulares oblíquos de 5,5mm e técnica com placa \"Y\" de compressão bloqueada de 5,0mm e sete orifícios / Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of one 3-Hole 4.5-mm Narrow Dynamic Compression Plate with two 5.5mm oblique cortex screws technique and one 7-Hole 5.0mm \"Y\" locking compression plate technique

Carlos Adolfo Salazar Latorre 25 June 2013 (has links)
As claudicações são a principal causa de encaminhamento de equinos aos médicos veterinários e uma das maiores causas de encaminhamento destes animais aos hospitais de referência; sendo as fraturas, especialmente aquelas de ossos longos e articulares, as que têm menor índice de sucesso devido ao prognóstico reservado e alto custo do tratamento; entendendo como sucesso o retorno do animal à função ou manutenção da qualidade de vida. A articulação interfalangeana proximal (AIP) dos equinos é clinicamente importante devido à apresentação frequente de claudicação, com lesões que comprometem a vida esportiva e função do equino. O objetivo desta pesquisa foi comparar biomecanicamente as características de duas técnicas de artrodese da AIP em equinos, utilizando-se placa de compressão dinâmica (DCP) de 4.5mm e três orifícios em combinação com dois parafusos corticais transarticulares de 5.5mm oblíquos inseridos pela técnica de tração (lag screw) e placa em "Y\" de compressão bloqueada (LCP) de 5,0mm e sete orifícios, com parafusos bloquados unicorticais e um parafuso cortical de 4.5mm oblíquo transarticular inserido no orifício central da placa, pela técnica de parafuso de tração. Foram utilizadas doze peças anatômicas de membros anteriores de equinos, das quais foi isolada a porção distal do membro desde a primeira falange até o casco. Uma vez preparadas as peças, cada par foi sorteado randomicamente para cada um dos dois grupos. Os modelos experimentais foram submetidos a ensaios biomecânicos de compressão axial em ciclo único até a sua falha. O tipo de falha ocorrida na placa, nos parafusos ou nos ossos foi avaliado, assim como a força à qual ocorreram estas falhas. Não houve diferença estatística significativa entre os grupos DCP e Y-LCP, nas variáveis rigidez e força máxima, quando submetidas a compressão axial até sua falha. Mesmo não havendo diferença entre as duas técnicas cirúrgicas na variável rigidez, a técnica Y-LCP possibilitou um procedimento menos invasivo e com menor tempo cirúrgico. Conclui-se que, as propriedades biomecânicas das duas técnicas de fixação (DCP e Y-LCP) são semelhantes nas condições testadas. / Lameness is the main cause of sport horses\' owners consulting equine veterinarians and one of the highest cause to send these animals to the reference hospitals. Long bones and joint fractures have the lesser rate of success, consequence of the hight cost of the treatment and poor prognosis. Understanding as success the return of the horse to previous athletic performance or at least to have useful life. The proximal interphalangeal joint (PIPJ) is clinically important because the injuries that involve it may threaten the horses sport life or its usefulness. The objective of this study was to compare the biomechanical properties of two PIPJ arthrodesis techniques using 4.5mm dynamic compression plate (DCP) in conjunction with two oblique abaxial transarticular 5.5mm cortical screws inserted in lag fashion and 5.0mm Y locking compression plate (Y-LCP) with unicortical locking screws and one axial transarticular 4.5mm cortex screw inserted in lag fashion through the midle plate hole. It was used twelve cadaveric adult equine forelimbs from the first phalanx to the foot. After full-limb preparations, each forelimb pair was randomly assigned to one of two treatment groups. Constructs were submited to axial compression single cycle to failure biomechanical testing. The failure of the screws, plate or bone, and the force at wich it happened was evaluated. There were no significant differences in construct stiffness or max force when loaded to failure, between the DCP and Y-LCP treatment groups. Even though there was no construct stiffness diffrences between the two techniques, the Y-LCP technique provided the possibility of a less invasive procedure with a shorter surgical time. In conclusion, the biomechanical properties of both fixation techniques (DCP and Y-LCP) are equivalent under the test conditions used.
10

Avaliação da resistência mecânica à compressão axial da poliuretana de mamona e quitosana associada a cimento de fosfato de cálcio no preenchimento de falhas ósseas do terceiro metacarpiano de equinos / Mechanical evaluation of strength of ricinus communis polyurethane and chitosan with calcium phosphate cement on filling of bone gap in equine third metacarpal bone

Rodrigo Crispim Moreira 30 May 2014 (has links)
Os equinos são animais que, quando adultos, apresentam elevado peso corpóreo e ossos bastante resistentes para sustentar esse peso. Dessa forma, para que ocorra fratura nos ossos do cavalo é necessário um trauma de elevada energia resultando em fraturas cominutivas, que podem formar falhas ósseas impedindo o contato entre os fragmentos ósseos, o que compromete a estabilidade e resistência da osteossíntese. Devido à complexidade desse tipo de fraturas e aos implantes disponíveis apresentarem baixa resistência para o uso nessa espécie e devido a seu comportamento, o tratamento de fraturas em equinos apresenta baixos índices de sucesso. Dessa maneira, o uso de um material osteocondutor com resistência mecânica para o preenchimento dessas falhas poderia elevar a resistência da osteossíntese, levando a melhores índices de sucesso na correção dessas fraturas. O presente estudo teve como objetivo a avaliação biomecânica em laboratório de dois biomateriais substitutos ósseos no preenchimento de falha óssea. Para isso foram utilizados 30 ossos terceiro metacarpiano de equinos que foram submetidos a osteossíntese com placa LCP em sua face dorsal e criada uma falha óssea transversal completa de um centímetro na diáfise média. Dez dessas peças foram submetidas a ensaios biomecânicos não destrutivos até a carga de 1000N, onde foram avaliadas a rigidez, as deformações da peça inteira, da placa e do osso individualmente em diferentes regiões. As outras 20 dessas peças foram submetidas a ensaios destrutivos, onde foram avaliadas a carga e deformação suportada no limite elástico e no ponto de ruptura. Dessa forma, pôde-se observar que houve aumento na rigidez de 699,39N/mm para 2905,38N/mm e 4274,93N/mm devido ao preenchimento da falha com poliuretana de mamona e quitosana, respectivamente. A peça inteira teve sua deformação diminuída de 1,73mm para 0,5mm e 0,35 com carga de 1000N, devido ao preenchimento da falha com poliuretana de mamona e quitosana, respectivamente. A placa teve sua deformação diminuída de 2260,64µd para 320,25µd pelo preenchimento da falha com poliuretana de mamona e para 89,88µd com o preenchimento com quitosana durante a aplicação de 1000N. O osso próximo à falha sofreu maiores deformações tanto com poliuretana de mamona quanto com quitosana, contudo não apresentou maiores deformações em região distante da falha. A peça inteira teve aumento da carga suportada em seu limite elástico de 1008N para 8804N apenas com o preenchimento da falha com quitosana. A peça inteira teve sua deformação diminuída de 1,64mm para 1,26 no limite elástico apenas devido ao preenchimento da falha poliuretana de mamona. A peça inteira teve aumento da força suportada no momento de ruptura de 1660N para 15187N e 11012N com o preenchimento da falha com poliuretana de mamona e quitosana, respectivamente. A peça inteira teve sua deformação máxima no ponto de ruptura diminuída de 5,4mm para 2,16mm apenas com o preenchimento da falha com quitosana. / Adult horses are heavy animals equipped with bones strong enough to support their body weight. High energy trauma is required to produce comminuted fractures, where bone loss may prevent proper fracture reduction and compromise osteosynthesis resistance and stability. In horses, aside from behavioural issues, low success rates associated with comminuted fracture resolution may be due to the complexity of such fractures or the low resistance of bone implants. Therefore, osteoconductive biomaterials with good mechanical resistance would potentially benefit treatment outcomes. This ex vivo study evaluated the biomechanical behaviour of two bone surrogate biomaterials in experimental third metacarpal fractures in horses. Thirty equine third metacarpal bone specimens were submitted to dorsal LCP (locking compression plate) osteosynthesis following creation of a transverse 1 cm wide middiaphiseal defect. Defects were filled either with Ricinus communis polyurethane or calcium phosphate cement-chitosan composite. Ten specimens were submitted to non-destructive biomechanical testing under 1000N maximum load; construct stiffness, construct deformation and isolated deformation of LCP and third metacarpal bone in different regions were evaluated. The remaining 20 specimens were submitted to destructive biomechanical testing; maximum load and deformation within the elastic limit, and to failure were documented. Bone defect repair with RCP or CPC-chitosan composite increased construct stiffness from 699,39N/mm to 2905.38N/mm and 4274.93N/mm and decreased construct deformation under 1000N from 1.73mm to 0,5mm and 0.35 respectively. LCP deformation under 1000N decreased from 2260.64d to 320.25µd and from 2260.64µd to 89.88d following filling of the bone defect with RCP or CPC-chitosan composite respectively. Bone deformation around the defect increased following treatment with RCP or CPC-chitosan composite. However bone deformation away from the defect remained unchanged. Maximum load within the elastic limit increased from 1008N to 8804N when the experimental defect was filled with chitosan composite. Conversely, construct deformation within the elastic limit decreased from 1.64mm to 1.26mm following treatment with RCP. Maximum load to construct failure increased from 1660N to 15187N and 11012N following bone defect repair with RCP or calcium phosphate cement-chitosan composite respectively. However, construct maximum deformation decreased from 5.4mm to 2.16mm when calcium phosphate cement-chitosan composite was used.

Page generated in 0.0485 seconds