• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • Tagged with
  • 22
  • 22
  • 18
  • 16
  • 16
  • 12
  • 12
  • 12
  • 11
  • 10
  • 6
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

"Estabilidade de cor de cerâmicas odontológicas submetidas ao processo de envelhecimento artificial acelerado após múltiplos ciclos de queima" / Color stability of ceramics restorations submitted to accelerated aging after multiple burn cycles

Fonseca, Karla Cristiane Vieira da 16 December 2005 (has links)
A estética tornou-se de fundamental importância nas últimas décadas, fazendo com que houvesse uma grande evolução nos materiais dentários e técnicas restauradoras para atender a esta exigência. As cerâmicas odontológicas são materiais estéticos e biocompatíveis, podendo ser uma ótima alternativa quando aplicadas a casos apropriadamente selecionados. O sucesso estético de uma restauração de cerâmica depende da caracterização de superfície, da integridade marginal, da forma anatômica e da coloração. O presente estudo teve o objetivo de avaliar a estabilidade de cor de dois tipos de restaurações em cerâmica odontológica, metalocerâmica e livre de metal, submetidas a múltiplos ciclos de queimas. Foram realizados 60 corpos-de-prova, sendo 30 na forma de metalocerâmicas e 30 livres de metal que foram divididas em três grupos de 10 amostras cada, sendo confeccionadas em duas, três e quatro queimas respectivamente. As leituras de cor foram realizadas em espectrofotômetro PCB 6807 BYK GARDNER antes e após envelhecimento artificial acelerado (Comexim Matérias Primas). Analisando-se inicialmente a influência do número de queimas sobre a cor da cerâmica odontológica, houve diferenças estatisticamente significantes para as coordenadas L* nas amostras metalocerâmicas, sendo que o grupo de 3 queimas foi o que apresentou diferenças em relação aos outros dois grupos. Para as amostras livres de metal, houve diferenças nas coordenadas L*, a* e b*, com comportamentos heterogêneos para as 3 coordenadas. Os resultados indicaram diferenças estatisticamente significantes na variação total de cor (&#8710;E) para as amostras de 3 e 4 queimas, comparando-se os tipos de restauração. Quando analisada a interferência do número de queimas de um mesmo tipo de restauração, não houve diferença estatisticamente significante para a amostra livre de metal. Para a amostra metalocerâmica, houve apenas diferença estatisticamente significante entre as amostras que receberam 2 e 3 queimas. Para a variação total nas coordenadas L*, a* e b* também houve variação de valores para os dois tipos de amostras e em relação aos ciclos de queimas. Concluiu-se que as pequenas diferenças estatisticamente significantes encontradas em alguns grupos não foram visíveis ao olho humano e portanto sem qualquer significado clínico (&#8710;E < 3,3). Além disso, os múltiplos ciclos de queima e o envelhecimento acelerado não modificaram de forma significativa a estabilidade de cor da cerâmica nas formas em que foi empregada (&#8710; < 1). / Esthetics has become essential over the past few decades, causing dental materials and restorative techniques to evolve significantly. Dental ceramics are esthetic and biocompatible materials which may be an excellent alternative for properly selected cases. The esthetic success of a ceramic’s restoration depends on surface characterization, marginal integrity, anatomic form, and color. This study aimed to assess the color stability of two types of dental ceramic restorations, metalloceramic and metal-free, submitted to multiple burn cycles. Sixty specimens were fabricated: 30 metalloceramic and 30 metal-free. The specimens were divided into 3 groups (n= 10) according to the number of burns (2, 3, and 4 burns). Color readings were performed using a PCB 6807 BYK GARDNER spectrophotometer before and after artificial accelerated aging (Comexim Raw Materials). By analyzing the influence of the number of burns over the dental ceramic’s color, statistically significant differences were found for the coordinate L* for the metalloceramic specimens, in the group of 3 burns, in relation to the other 2 groups. For the metal-free specimens, there were differences for the coordinates L*, a*, and b*, with heterogeneous compartments for the 3 coordinates. The results revealed statistically significant differences for total color variation (&#8710;E) for the 3 burns group, in comparison to the other types of restoration. When analyzing the specimens of a single type of material, in terms of the interference of the number of burns, the metal-free samples showed no statistically significant differences, whereas the metalloceramic samples showed difference only between those that received 2 and 3 burns. For the total variation of coordinates L*, a*, and b*, both materials showed a variation in those values and in relation to burn cycles. The small statistically significant differences found in some groups are invisible and present no clinical meaning (&#8710;E<3.3). In addition, the multiple burn cycles and accelerated aging did not modify significantly the ceramic’s color stability (&#8710;<1).
12

Influência do envelhecimento artificial acelerada sobre a estabilidade de cor, opacidade e densidade das ligações cruzadas de compósitos odontológicos armazenados em diferentes ambientes e tempos de armazenagem / Influence of artificial accelerated aging on color stability, opacity and cross-link density of dental composites stored in different environment and over different times

Fabrício Mariano Mundim 09 November 2007 (has links)
A evolução sofrida pelas resinas compostas, aliada à sua característica de restaurar a aparência natural dos dentes em relação à cor e opacidade, torna esses materiais uma das principais escolhas entre os materiais restauradores usados na odontologia. A estabilidade de cor e a opacidade assumem um papel crucial no sucesso do tratamento restaurador estético, pois a alteração destas características pode indicar a substituição das restaurações estéticas. Essas propriedades estão relacionadas ao grau de conversão desses materiais no momento da polimerização. O objetivo deste trabalho foi avaliar a influência do envelhecimento artificial acelerado sobre a estabilidade de cor, opacidade e densidade das ligações cruzadas de compósitos armazenados por 30 e 90 dias em ambientes diferentes (temperatura ambiente/geladeira). Foram utilizados 5 compósitos odontológicos em duas tonalidades: claras e escuras. As embalagens dos compósitos foram mantidas em temperatura ambiente (+/- 25ºC) e em geladeira (+/- 8ºC), sendo armazenados nestes ambientes por 30 e 90 dias, para posterior confecção dos corpos-de-prova (12 mm de diâmetro / 2 mm de espessura). Sobre essas amostras, foram realizadas as leituras da alteração de cor ( E), opacidade (OP), e densidade das ligações cruzadas, previamente e posteriormente a realização do procedimento de envelhecimento artificial acelerado. Após análise estatística (2-way ANOVA - Tukey - nível de significância em p<0.05), observou-se que compósitos QuiXfil Universal, Tetric EvoCeram C3 e SR Adoro A2, apresentaram valores para alteração de cor clinicamente inaceitável ( E 3,3). Quanto à opacidade, as resinas diretas, de tonalidades claras apresentaram menor opacidade que as tonalidades escuras enquanto que a resina indireta apresentou maior opacidade para a tonalidade clara que a escura. Quanto à densidade de ligações cruzadas, o envelhecimento artificial acelerado produziu um aumento na densidade de ligações cruzadas das resinas diretas. Concluiu-se que não houve um comportamento homogêneo dos materiais, em relação às propriedades estudadas, em função do tempo e ambiente de armazenagem sugerindo que a ação do envelhecimento é primordial e mais relevante para a alteração dos materiais ao longo do tempo. / The evolution of composite resins, allied to their characteristic of restoring the natural appearance of teeth regarding color and opacity, makes them one of the main materials of choice among the restorative materials used in dentistry. Color and opacity stability assume a crucial role in a successful aesthetic restoration treatment, since changes in these characteristics may indicate the replacement of aesthetic restorations. These properties are associated with these materials\' degree of conversion at the moment of polymerization. The purpose of this study was to evaluate the influence of artificial accelerated aging on color stability, opacity, and density of cross-links in composites stored for 30 and 90 days in different environments (room temperature/refrigerator). Five dental composites were used, with two shades: light and dark. Composite packages were kept in room temperature (+/- 25ºC) and in a refrigerator (+/- 8ºC), for 30 and 90 days, for posterior specimen fabrication (12 mm in diameter / 2 mm thick). Specimens were subjected to readings for color change ( E), opacity (OP), and cross-link density, before and after artificial accelerated aging. Statistical analysis (2-way ANOVA - Tukey - level of significance at p<0.05), revealed that QuiXfil Universal, Tetric EvoCeram C3, and SR Adoro A2 composites presented clinically unacceptable color changes ( E 3.3). Regarding opacity, light shade direct resins presented less opacity compared to dark shades, whereas light shade indirect resins presented more opacity than dark ones. As to cross-link density, artificial accelerated aging increased crosslink density in direct resins. It is concluded that the materials did not behave homogenously, in terms of the studied properties, under the effects of storage time and environment. This suggests that the effects of aging are imperative and more relevant to material changes over time.
13

"Estabilidade de cor de cerâmicas odontológicas submetidas ao processo de envelhecimento artificial acelerado após múltiplos ciclos de queima" / Color stability of ceramics restorations submitted to accelerated aging after multiple burn cycles

Karla Cristiane Vieira da Fonseca 16 December 2005 (has links)
A estética tornou-se de fundamental importância nas últimas décadas, fazendo com que houvesse uma grande evolução nos materiais dentários e técnicas restauradoras para atender a esta exigência. As cerâmicas odontológicas são materiais estéticos e biocompatíveis, podendo ser uma ótima alternativa quando aplicadas a casos apropriadamente selecionados. O sucesso estético de uma restauração de cerâmica depende da caracterização de superfície, da integridade marginal, da forma anatômica e da coloração. O presente estudo teve o objetivo de avaliar a estabilidade de cor de dois tipos de restaurações em cerâmica odontológica, metalocerâmica e livre de metal, submetidas a múltiplos ciclos de queimas. Foram realizados 60 corpos-de-prova, sendo 30 na forma de metalocerâmicas e 30 livres de metal que foram divididas em três grupos de 10 amostras cada, sendo confeccionadas em duas, três e quatro queimas respectivamente. As leituras de cor foram realizadas em espectrofotômetro PCB 6807 BYK GARDNER antes e após envelhecimento artificial acelerado (Comexim Matérias Primas). Analisando-se inicialmente a influência do número de queimas sobre a cor da cerâmica odontológica, houve diferenças estatisticamente significantes para as coordenadas L* nas amostras metalocerâmicas, sendo que o grupo de 3 queimas foi o que apresentou diferenças em relação aos outros dois grupos. Para as amostras livres de metal, houve diferenças nas coordenadas L*, a* e b*, com comportamentos heterogêneos para as 3 coordenadas. Os resultados indicaram diferenças estatisticamente significantes na variação total de cor (&#8710;E) para as amostras de 3 e 4 queimas, comparando-se os tipos de restauração. Quando analisada a interferência do número de queimas de um mesmo tipo de restauração, não houve diferença estatisticamente significante para a amostra livre de metal. Para a amostra metalocerâmica, houve apenas diferença estatisticamente significante entre as amostras que receberam 2 e 3 queimas. Para a variação total nas coordenadas L*, a* e b* também houve variação de valores para os dois tipos de amostras e em relação aos ciclos de queimas. Concluiu-se que as pequenas diferenças estatisticamente significantes encontradas em alguns grupos não foram visíveis ao olho humano e portanto sem qualquer significado clínico (&#8710;E < 3,3). Além disso, os múltiplos ciclos de queima e o envelhecimento acelerado não modificaram de forma significativa a estabilidade de cor da cerâmica nas formas em que foi empregada (&#8710; < 1). / Esthetics has become essential over the past few decades, causing dental materials and restorative techniques to evolve significantly. Dental ceramics are esthetic and biocompatible materials which may be an excellent alternative for properly selected cases. The esthetic success of a ceramic’s restoration depends on surface characterization, marginal integrity, anatomic form, and color. This study aimed to assess the color stability of two types of dental ceramic restorations, metalloceramic and metal-free, submitted to multiple burn cycles. Sixty specimens were fabricated: 30 metalloceramic and 30 metal-free. The specimens were divided into 3 groups (n= 10) according to the number of burns (2, 3, and 4 burns). Color readings were performed using a PCB 6807 BYK GARDNER spectrophotometer before and after artificial accelerated aging (Comexim Raw Materials). By analyzing the influence of the number of burns over the dental ceramic’s color, statistically significant differences were found for the coordinate L* for the metalloceramic specimens, in the group of 3 burns, in relation to the other 2 groups. For the metal-free specimens, there were differences for the coordinates L*, a*, and b*, with heterogeneous compartments for the 3 coordinates. The results revealed statistically significant differences for total color variation (&#8710;E) for the 3 burns group, in comparison to the other types of restoration. When analyzing the specimens of a single type of material, in terms of the interference of the number of burns, the metal-free samples showed no statistically significant differences, whereas the metalloceramic samples showed difference only between those that received 2 and 3 burns. For the total variation of coordinates L*, a*, and b*, both materials showed a variation in those values and in relation to burn cycles. The small statistically significant differences found in some groups are invisible and present no clinical meaning (&#8710;E<3.3). In addition, the multiple burn cycles and accelerated aging did not modify significantly the ceramic’s color stability (&#8710;<1).
14

Efeito do envelhecimento artificial acelerado na estabilidade de cor de cimentos resinosos para cimentação de laminados cerâmicos / Effect of accelerated artificial aging on color stability of resin cements for luting ceramic laminates

Francisca Daniele Jardilino Silame 10 April 2013 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor de cimentos resinosos para fixação de restaurações cerâmicas em diferentes espessuras submetidas ao envelhecimento artificial acelerado (EAA). Foram utilizados 60 molares humanos hígidos, cujas porções radiculares foram incluídas em matriz de PVC (15 mm de diâmetro) com resina acrílica e as faces oclusais foram planificadas, 30 em esmalte e 30 até dentina, sendo que 10 dentes de cada substrato foram considerados gruposcontrole para os dentes restaurados. Foram obtidos 40 corpos de prova em cerâmica (IPS e-max Ceram, Ivoclar Vivadent), com 0,5 mm e 1,0 mm, que foram separados aleatoriamente em dois grupos (n=10) segundo o tipo de cimento resinoso dual utilizado para fixação: convencional (Variolink II, Ivoclar/Vivadent) ou auto-adesivo (Rely-X Unicem, 3M ESPE). Além desses, foram obtidos 10 corpos de prova de cada cimento resinoso (0,5mm), considerado grupo-controle para os materiais. Todas as amostras foram mantidas em estufa a 37ºC por 24h, após o qual foram realizadas as leituras de cor iniciais (Vita EasyShade, VITA). Em seguida, foram submetidas ao EAA por 580 horas, após o qual novas leituras de cor foram realizadas. Foi avaliada estabilidade de cor e a luminosidade. Os dados de estabilidade de cor (&Delta;E) e luminosidade (&Delta;L) obtidos foram submetidos a análise estatística (2-way ANOVA, Bonferroni, p<0,05) e a comparação dos materiais com os grupos controles foi realizada utilizando 1-way ANOVA e teste de Tukey (p<0,05). O cimento dual convencional apresentou maior alteração de cor e luminosidade quando sob a restauração de 0,5mm, diferente estatisticamente (p<0,05) de restaurações de 1,0mm. Não houve diferença estatisticamente significante (p>0,05) quando comparados os materiais. Quando analisadas a estabilidade de cor e luminosidade dos grupos com restaurações em relação aos grupos-controle, verificou-se que ambos os cimentos apresentaram maiores alterações, diferente estatisticamente (p<0,05) dos demais grupos, com exceção ao grupo de 0,5mm em relação ao Grupo esmalte quando analisado o cimento dual convencional (p>0,05). Concluiu-se que quanto menor a espessura da restauração, maior a alteração de cor e de luminosidade do cimento dual convencional. As alterações do cimento autoadesivo não dependem da espessura da restauração. / The aim of this study was to evaluate the color stability of resin cements for luting ceramic restorations with different thicknesses submitted to accelerated artificial aging (AAA). Sixty sound human molars had their root portions embedded in PVC rings (15-mm diameter) with acrylic resin. Their occlusal surfaces were flattened according two substrates: 30 surfaces until enamel and 30 until dentin. Then, 10 teeth of each substrate were considered as control groups for restored teeth. Forty specimens of ceramic (IPS e-max Ceram, Ivoclar Vivadent) were obtained with two different thicknesses (0.5 mm and 1.0 mm) and were randomly separated into two groups (n = 10) according to the type of the Dual resin cement used for luting: conventional (Variolink II, Ivoclar / Vivadent) or self-adhesive (Rely-X Unicem, 3M ESPE). Also, 10 specimens (0.5 mm) of each cement were obtained to be considered as control groups for materials. All specimens were stored at 37º C for 24 hours, and initial color readings (Vita Easyshade, VITA) were performed. Then, they were submitted to AAA for 580 hours, and final color readings were taken. Color stability and brightness were evaluated. Data of color stability (&Delta;E) and brightness (&Delta;L) were statistically analyzed (2- way ANOVA, Bonferroni, p<0.05) and the comparison of materials with control groups was performed using one-way ANOVA and Tukeys test (p<0.05). The conventional dual cement showed the greatest change in color and brightness when under restorations of 0.5 mm, statistically different (p<0.05) to restorations of 1.0 mm. There was no statistically significant difference (p>0.05) when comparing materials. When analyzing the color stability and brightness of restorations groups compared to control groups, both cements showed greater changes, statistically different (p<0.05), than other groups, except for the group of 0.5 mm in relation to enamel group when the dual conventional cement was analyzed (p>0.05). It was concluded that the smaller the thickness of the restoration, the greater the color and brightness changes of the dual conventional cement. Changes of the self-adhesive cement do not depend on the thickness of the restoration.
15

Efeito da escovação e do envelhecimento artificial acelerado sobre a alteração superficial de materiais restauradores estéticos / Effect of simulated toothbrushing and accelerated artificial aging on surface degradation of aesthetic restorative materials

Roselino, Lourenço de Moraes Rego 11 April 2012 (has links)
O objetivo desse estudo foi avaliar sistematicamente o efeito da escovação simulada e do envelhecimento artificial acelerado (EAA) sobre estabilidade de cor e rugosidade de superfície de compósitos odontológicos de nanopartículas (Z350 - 3M ESPE) e híbrido (Tetric N-Ceram - Ivoclar Vivadent). Foram confeccionados 24 corpos-de-prova (12mm de diâmetro X 2mm de espessura) para cada compósito e uma cerâmica de revestimento (IPS e.max Ceram - Ivoclar Vivadent) como controle. Após sua confecção, os corpos-de-prova foram polidos com lixas d&lsquo;água em abrasividades decrescentes (compósitos = 600, 1200 e 2000 e cerâmica = 100, 320, 1200 e 2000). Em seguida, foram realizadas leituras iniciais de cor (Espectrofotômetro PCB 6807) e rugosidade de superfície (Rugosímetro Surfcorder SE 1700 - Kosakalab). As amostras foram separadas em 3 grupos (n=8), segundo o tratamento a que foram submetidas: Grupo 1: EAA; Grupo 2: escovação mecânica com dentifrício RDA* 68 (Colgate); e Grupo 3: escovação mecânica com dentifrício RDA* 180 (Colgate Total Plus Whitening). Após 480 horas de EAA e em intervalos de 41 minutos de escovação (=14.600 ciclos) até 205 minutos novas leituras de cor e rugosidade de superfície foram realizadas. Amostras inicialmente submetidas a EAA (n=4) receberam escovação mecânica com dentifrício RDA* 68 e 180, conforme metodologia descrita anteriormente e novas leituras de cor e rugosidade foram obtidas. Os dados (antes e após os testes) foram analisados estatisticamente (2-way ANOVA análises repetidas, Bonferroni, p<0,05) e verificou-se que houve maior alteração de cor dos compósitos quando submetidos a EAA com diferença estatisticamente significante (p<0,05) em relação à escovação mecânica. Não houve diferença estatisticamente significante (p>0,05) na estabilidade de cor dos materiais quando comparadas as abrasividades dos dentifrícios, porém esse fator foi significante para a alteração de rugosidade de superfície (p<0,05), sendo maior quando os materiais foram escovados com RDA* 180. Quanto ao tempo de escovação, não houve diferença estatisticamente significante (p>0,05) para a alteração de cor e de rugosidade de superfície dos materiais, o mesmo ocorrendo para amostras escovadas após EAA. Conclui-se que o EAA interfere na estabilidade de cor e a escovação simulada nas alterações de rugosidade de superfície dos compósitos, independente do tempo de utilização do dentifrício, sendo maior para dentifrícios mais abrasivos. Além disso, a abrasividade e o tempo de utilização do dentifrício não alteram a capacidade de remoção do manchamento e a rugosidade de superfície de compósitos. / The purpose of this study was to evaluate the effect of simulated toothbrushing and accelerated artificial aging (AAA) on color stability and surface roughness of nanofill (Z350 - 3M ESPE) and hybrid (Tetric N-Ceram - Ivoclar Vivadent) composites. Twenty-four diskshaped specimens (12mm in diameter X 2 mm thick) were made for each composite and one feldspatic ceramic (IPS e.max Ceram - Ivoclar Vivadent) as a control. The specimens were polished with decreasing abrasiveness sandpapers (composites = 600, 1200, 2000 and ceramic = 100, 320, 1200, 2000). Then, initial readings were taken on color (Spectrophotometer PCB 6807) and surface roughness (Rugosimeter Surfcorder SE 1700 - Kosakalab). The samples were separated in 3 groups (n=8) according to the submitted treatments: Group 1: AAA; Group 2: mechanical brushing with dentifrice RDA* 68 (Colgate); and Group 3: mechanical brushing with dentifrice RDA* 180 (Colgate Total Plus Whitening). New readings on color and surface roughness were taken after 480 hours of AAA and in intervals of 41 minutes of brushing (=14.600 cycles) until 205 minutes. The samples initially submitted to AAA (n=4) received mechanical brushing with dentifrice RDA* 68 and 180, according to previously described methodology and new readings on color and roughness were taken. Data (before and after tests) were statistically analyzed (2- way ANOVA repeated measures, Bonferroni, p<0,05) and it was observed a higher composite color alteration compared with mechanical brushing when submitted to AAA with a statistically significant difference (p<0,05) between them. There was no statistically significant difference (p>0,05) on color stability of materials when the dentifrices abrasiveness were compared, but it was significant for surface roughness degradation (p<0,05), higher when materials were brushed with RDA* 180. Regarding time brushing, there was no statistically significant difference (p>0,05) for color alteration and roughness surface of materials and the same occurred for samples brushed after AAA. It was concluded that AAA interferes on color stability and the simulated brushing on surface roughness degradation of composites regardless the time of used dentifrice, but it was higher for more abrasive dentifrices. Moreover, abrasiveness and time of used dentifrice do not alter the capacity of staining removal and the surface roughness of composites.
16

Tratamento térmico de envelhecimento da liga de fundição AlSi10Mg(Fe)

Lima, Nuno Alexandre Gonçalves January 2012 (has links)
Estágio realizado na empresa Traterme Tratamentos Térmicos, Lda. - e orientado pelo Eng. J. Alexandre Silva / Tese de mestrado integrado. Engenharia Metalúrgica e de Materiais. Faculdade de Engenharia. Universidade do Porto. 2012
17

Análise da efetividade de polimerização, adaptação marginal e interna de restaurações Classe II de resinas compostas de inserção em bloco utilizando diferentes matrizes / Effectiveness of cure, marginal and internal adaptation of Class II bulk-fill composites restorations made with different matrices bands

Gutierrez, Natália Cortez [UNESP] 11 February 2016 (has links)
Submitted by NATÁLIA CORTEZ GUTIERREZ null (natycg22@hotmail.com) on 2016-04-05T16:41:57Z No. of bitstreams: 1 TESE NATALIA CORTEZ GUTIERREZ.pdf: 1565983 bytes, checksum: f66fa4688260558df32b38d76df46e78 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-04-07T19:24:53Z (GMT) No. of bitstreams: 1 gutierrez_nc_dr_sjc.pdf: 1565983 bytes, checksum: f66fa4688260558df32b38d76df46e78 (MD5) / Made available in DSpace on 2016-04-07T19:24:53Z (GMT). No. of bitstreams: 1 gutierrez_nc_dr_sjc.pdf: 1565983 bytes, checksum: f66fa4688260558df32b38d76df46e78 (MD5) Previous issue date: 2016-02-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi analisar a efetividade de polimerização, a adaptação marginal e interna de resinas compostas para dentes posteriores, empregando diferentes matrizes associadas ao envelhecimento artificial. Cento e vinte incisivos bovinos foram cortados e desgastados para simular dentes posteriores, nos quais foram realizados preparados de Classe II, com o ângulo cavosuperficial gengival em dentina. As cavidades tinham 6 mm de altura (ocluso-cervical), 3 de largura (vestibulo-lingual) e 1,5 de profundidade (mesio-distal). Os espécimes foram divididos em seis grupos de acordo com o material restaurador utilizado: GrandioSO (Voco)– convencional incremental, G-aenial universal flo (GC)– fluída incremental, X-tra fil (Voco)– convencional com inserção em bloco, X-tra base (Voco)– fluída com inserção em bloco, Venus Bulk Fill (Kulzer)– fluída com inserção em bloco e SureFil SDR (Dentsply)– fluída com inserção em bloco. As resinas fluídas com inserção em bloco foram inseridas em incremento de 4 mm e receberam uma cobertura oclusal de 2 mm utilizando a resina GrandioSO, com exceção da X-tra fil que foi coberta com uma camada adicional do mesmo material. Nos demais grupos foi utilizada uma técnica incremental de 2 mm. Metade dos espécimes foi restaurada com matriz metálica e a outra metade com matriz de poliéster. O percentual de polimerização foi mensurado através da dureza Knoop e da relação dureza base/topo. A média da largura das fendas marginais presentes nas margens de cada restauração foi calculada após medição, em micrometros, no microscópio óptico (100x). Os espécimes foram submetidos à ciclagem mecânica (500,000 ciclos) e térmica (1,000 ciclos) e a fenda marginal foi avaliada novamente. Para fenda interna, os espécimes foram seccionados em uma cortadeira de precisão e o comprimento, em milímetros, da parede gengival que apresentava fenda foi mensurado no microscópio óptico. Foi calculada então a porcentagem de fenda em relação ao comprimento total da parede (1,5 mm). Os dados foram submetidos à ANOVA dois e três fatores. Com relação ao percentual de polimerização, houve diferença para o fator resina (p=0,001). As resinas G-aenial universal flo (82,08%) e GrandioSO (84,62%) apresentaram os maiores percentuais de cura. Para fenda marginal foi encontrada diferença significativa para todos os fatores (p<0,05). As resinas Venus Bulk e SDR apresentaram as menores médias de fenda marginal (19,16 e 19,62 µm, respectivamente) e GrandioSO a maior (26,88 µm). As restaurações com matriz de poliéster resultaram em fendas menos largas (21,08 µm) que com matriz metálica (23,27 µm). Todos os grupos apresentaram fendas marginais mais largas após a ciclagem. Com relação à fenda interna, houve diferença apenas para o fator resina (p=0,001). Somente a resina GrandioSO apresentou fenda em mais da metade da parede gengival (53,96%). As resinas de incremento em bloco apresentaram menores valores de fenda marginal e interna do que a resina convencional. Porém, não apresentaram eficiência de cura superior à 80% (dureza da base em relação ao topo). / The aim of this study was to analyze the effectiveness of cure, marginal and internal adaptation of composite resins for posterior teeth using different matrices bands associated with artificial aging. One hundred and twenty bovine incisors were cut and flattened in order to simulate posterior teeth, and then were prepared for class II cavities with gingival cavosurface margin in dentin. Cavities had 6 mm height (occluso-cervical), 3 mm width (bucco-lingual) and 1.5 mm deep (mesio-distal). Specimens were divided into six groups according to the restorative material: GrandioSO (Voco)- conventional, G-aenial universal flo (GC)- flowable, X-tra fil (Voco)- conventional bulk, X-tra base (Voco)- flowable bulk, Venus Bulk Fill (Kulzer)- flowable bulk, and SureFil SDR (Dentsply)- flowable bulk. Bulk-fill composites were placed in single increment of 4mm and received a 2mm occlusal coverage of GrandioSO, with the exception of X-tra fil which was covered with a layer of the same material. The remmaing groups were restored in 2 mm incremental technique. Half of the specimens were restored with metallic and the other half with polyester matrix. Effectiveness of cure was measured by Knoop hardness and the bottom/top hardness ratio was evaluated. The average width of marginal gaps present in the restoration was calculated after optical microscope measuring (100x), in microns. The specimens were subjected to mechanical (500.000 cycles) and thermal cycling (1.000 cycles) and marginal gap was evaluated again. For internal adaptation, the specimens were sectioned and the gap length, in millimeters, present on the gingival wall was measured in an optical microscope. The percentage of gap length in relation to the total length of the wall was also calculated. Data were analyzed with three and two-way ANOVA and Tukey´s test. Regarding effectiveness of cure, significant differences were observed for resin factor. Composites G-aenial universal flo (82.08%) and GrandioSO (84.62%) had the highest cure rates. For marginal gap, significant differences were observed for all factors (p<0.05). Venus Bulk (19.16 µm) and SDR (19.62 µm) had the narrower and GrandioSO (26.88 µm) the wider gap. For matrix factor, groups restored with polyester (21.08 µm) had narrower gaps than metallic (23.27 µm). All groups showed wider gaps after aging. For internal adaptation, the only difference found was for resin factor (p=0.001). Conventional composite GrandioSO presented gap in more than half of the gingival wall (53.96%). Bulk-fill composites showed lower values of marginal and internal gap than conventional composite. However, none of the bulk-fill composites showed efficiency of cure of 80% or more.
18

Estudo do comportamento da liga Al-Mg-Si 6005 A solubilizada e envelhecida

Bonfitto, Guilherme Bruno Barroso 09 August 2016 (has links)
Submitted by Rosa Assis (rosa_assis@yahoo.com.br) on 2017-04-10T12:03:21Z No. of bitstreams: 2 Guilherme Bruno Barroso Bonfitto.pdf: 4296266 bytes, checksum: 5092519d6b5bf1138c9d85efce8d53c4 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Paola Damato (repositorio@mackenzie.br) on 2017-04-20T15:36:43Z (GMT) No. of bitstreams: 2 Guilherme Bruno Barroso Bonfitto.pdf: 4296266 bytes, checksum: 5092519d6b5bf1138c9d85efce8d53c4 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-04-20T15:36:43Z (GMT). No. of bitstreams: 2 Guilherme Bruno Barroso Bonfitto.pdf: 4296266 bytes, checksum: 5092519d6b5bf1138c9d85efce8d53c4 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-08-09 / The possibility of increase use of aluminum in place of ferrous materials and wood in automotive industry, mainly in manufacturing of bus and truck structure, corrosion resistance, high ratio resistance and weight due low density and cost are the main reasons for this study. The alloy 6005A without any heat treatment appears disadvantageous compared to other alloys of aluminum and ferrous materials, however, with appropriate heat treatment, the mechanical properties are improved considerably, which is the case of this study. After comparisons in 36 different conditions of temperature of solubilization and temperature and time of artificial aging, the temperatures of 545ºC (30 minutes followed by water cooling) and 185°C (4 hours) solubilizing and artificial aging, respectively, showed the best growth of hardness alloy 63HRF to 85HRF. The metallography alloy after quenching was performed by optical microscopy showed in the microstructure equiaxed grains with homogeneous distribution. When compared the microstructures with different oven time and temperature, it was not showed the difference that relates the difference in hardness. It was realized the tensile test and the tensile strength limit values (σt) 279,21MPa and yield strength (σe) 257,33 MPa are among the average values for the alloy 6005A T6. The study of fatigue alloy was realized in a rotating bending testing machine (R=-1) at ambient temperature and the data was analyzed in a S-N curve. When applied stress less than 117,42 MPa, the specimen supported more than 1,0x107 cycles before breaking down. The fracture surfaces of the specimens with many tensile were analyzed by optical microscopy and by SEM and indicated the presence of ratchet marks, stretch marks, and integranular and transgranular cracks. / A possibilidade de crescimento da utilização do alumínio em substituição aos materiais ferrosos e de madeira no ramo automobilístico, principalmente na fabricação de carrocerias de ônibus e caminhão, resistência à corrosão, elevada razão resistência e peso devido a baixa massa específica e custo são as principais justificativas para este estudo. A liga 6005A sem nenhum tratamento térmico se apresenta desvantajosa em relação às demais ligas de alumínio e materiais ferrosos, porém, com o tratamento térmico adequado, suas propriedades mecânicas são aperfeiçoadas consideravelmente, que é o caso deste estudo. Após comparações em 36 condições distintas de temperatura de solubilização e temperatura e tempo em forno de envelhecimento artificial, as temperaturas de 545ºC (30 minutos seguido de resfriamento em água) e 185ºC e (4 horas) de solubilização e envelhecimento, respectivamente, foram as que apresentaram melhor incremento de dureza da liga de 63HRF para 85HRF. A metalografia da liga após têmpera foi realizada por microscopia óptica e apresentou na microestrutura grãos equiaixiais com distribuição homogênea. Quando comparada as microestruturas com tempos e temperatura distintas em forno, não foi visto nenhuma diferença que relacionasse a diferença da dureza. Realizado o ensaio de tração e os valores de limite resistência a tração (σt) de 279,21MPa, limite escoamento (σe) de 257,33 MPa estão entre os valores médios para a liga 6005A T6. O estudo de fadiga da liga foi realizado em uma máquina fadiga flexo-rotativa de ciclo reverso tensão-compressão (R=-1) à temperatura ambiente e os dados analisados em uma curva S-N. Com tensão de até 117,42 MPa, o corpo de prova suportou número de ciclos maior que 1,0x107 ciclos antes de romper. As superfícies de fratura dos corpos de prova com cargas variadas foram analisados através de microscopia ótica e pelo MEV e indicaram presença de marcas de catraca, estrias, clivagem e trincas integranulares e transgranulares.
19

Efeito da escovação e do envelhecimento artificial acelerado sobre a alteração superficial de materiais restauradores estéticos / Effect of simulated toothbrushing and accelerated artificial aging on surface degradation of aesthetic restorative materials

Lourenço de Moraes Rego Roselino 11 April 2012 (has links)
O objetivo desse estudo foi avaliar sistematicamente o efeito da escovação simulada e do envelhecimento artificial acelerado (EAA) sobre estabilidade de cor e rugosidade de superfície de compósitos odontológicos de nanopartículas (Z350 - 3M ESPE) e híbrido (Tetric N-Ceram - Ivoclar Vivadent). Foram confeccionados 24 corpos-de-prova (12mm de diâmetro X 2mm de espessura) para cada compósito e uma cerâmica de revestimento (IPS e.max Ceram - Ivoclar Vivadent) como controle. Após sua confecção, os corpos-de-prova foram polidos com lixas d&lsquo;água em abrasividades decrescentes (compósitos = 600, 1200 e 2000 e cerâmica = 100, 320, 1200 e 2000). Em seguida, foram realizadas leituras iniciais de cor (Espectrofotômetro PCB 6807) e rugosidade de superfície (Rugosímetro Surfcorder SE 1700 - Kosakalab). As amostras foram separadas em 3 grupos (n=8), segundo o tratamento a que foram submetidas: Grupo 1: EAA; Grupo 2: escovação mecânica com dentifrício RDA* 68 (Colgate); e Grupo 3: escovação mecânica com dentifrício RDA* 180 (Colgate Total Plus Whitening). Após 480 horas de EAA e em intervalos de 41 minutos de escovação (=14.600 ciclos) até 205 minutos novas leituras de cor e rugosidade de superfície foram realizadas. Amostras inicialmente submetidas a EAA (n=4) receberam escovação mecânica com dentifrício RDA* 68 e 180, conforme metodologia descrita anteriormente e novas leituras de cor e rugosidade foram obtidas. Os dados (antes e após os testes) foram analisados estatisticamente (2-way ANOVA análises repetidas, Bonferroni, p<0,05) e verificou-se que houve maior alteração de cor dos compósitos quando submetidos a EAA com diferença estatisticamente significante (p<0,05) em relação à escovação mecânica. Não houve diferença estatisticamente significante (p>0,05) na estabilidade de cor dos materiais quando comparadas as abrasividades dos dentifrícios, porém esse fator foi significante para a alteração de rugosidade de superfície (p<0,05), sendo maior quando os materiais foram escovados com RDA* 180. Quanto ao tempo de escovação, não houve diferença estatisticamente significante (p>0,05) para a alteração de cor e de rugosidade de superfície dos materiais, o mesmo ocorrendo para amostras escovadas após EAA. Conclui-se que o EAA interfere na estabilidade de cor e a escovação simulada nas alterações de rugosidade de superfície dos compósitos, independente do tempo de utilização do dentifrício, sendo maior para dentifrícios mais abrasivos. Além disso, a abrasividade e o tempo de utilização do dentifrício não alteram a capacidade de remoção do manchamento e a rugosidade de superfície de compósitos. / The purpose of this study was to evaluate the effect of simulated toothbrushing and accelerated artificial aging (AAA) on color stability and surface roughness of nanofill (Z350 - 3M ESPE) and hybrid (Tetric N-Ceram - Ivoclar Vivadent) composites. Twenty-four diskshaped specimens (12mm in diameter X 2 mm thick) were made for each composite and one feldspatic ceramic (IPS e.max Ceram - Ivoclar Vivadent) as a control. The specimens were polished with decreasing abrasiveness sandpapers (composites = 600, 1200, 2000 and ceramic = 100, 320, 1200, 2000). Then, initial readings were taken on color (Spectrophotometer PCB 6807) and surface roughness (Rugosimeter Surfcorder SE 1700 - Kosakalab). The samples were separated in 3 groups (n=8) according to the submitted treatments: Group 1: AAA; Group 2: mechanical brushing with dentifrice RDA* 68 (Colgate); and Group 3: mechanical brushing with dentifrice RDA* 180 (Colgate Total Plus Whitening). New readings on color and surface roughness were taken after 480 hours of AAA and in intervals of 41 minutes of brushing (=14.600 cycles) until 205 minutes. The samples initially submitted to AAA (n=4) received mechanical brushing with dentifrice RDA* 68 and 180, according to previously described methodology and new readings on color and roughness were taken. Data (before and after tests) were statistically analyzed (2- way ANOVA repeated measures, Bonferroni, p<0,05) and it was observed a higher composite color alteration compared with mechanical brushing when submitted to AAA with a statistically significant difference (p<0,05) between them. There was no statistically significant difference (p>0,05) on color stability of materials when the dentifrices abrasiveness were compared, but it was significant for surface roughness degradation (p<0,05), higher when materials were brushed with RDA* 180. Regarding time brushing, there was no statistically significant difference (p>0,05) for color alteration and roughness surface of materials and the same occurred for samples brushed after AAA. It was concluded that AAA interferes on color stability and the simulated brushing on surface roughness degradation of composites regardless the time of used dentifrice, but it was higher for more abrasive dentifrices. Moreover, abrasiveness and time of used dentifrice do not alter the capacity of staining removal and the surface roughness of composites.
20

Avaliação da influência do envelhecimento artificial acelerado e armazenamento em fluorfosfato acidulado a 1,23% na rugosidade superficial e na alteração de cor de cerâmicas odontológicas de ultra-baixa fusão para titânio comercialmente pur / Evaluation of the influence of the accelerated artificial aging and storage in 1.23% acidulated phosphate fluoride over superficial roughness and color stability of two low-fusing dental ceramics to commercially pure titanium

Janisse Martinelli Borges de Oliveira 20 December 2007 (has links)
O objetivo do trabalho foi avaliar a influência do envelhecimento artificial acelerado e do fluorfosfato acidulado a 1,23% sobre a rugosidade superficial e alteração de cor de duas cerâmicas odontológicas de ultra-baixa fusão para titânio (Triceram- Dentaurum, e Noritake Ti22- Noritake), livre de metal ou com subestrutura em titânio comercialmente puro (Tritan- Dentaurum). A partir de uma matriz cilíndrica em teflon foram confeccionados, ao todo, 80 corpos-de-prova, com 15mm de diâmetro e 2,5mm de espessura, sendo 40 para cada cerâmica, 20 amostras livre de metal e 20 metalocerâmicas, que foram divididas em dois grupos de 10 amostras cada, sendo submetidas ao envelhecimento artificial acelerado (Sistema Acelerado de Envelhecimento para não-metálicos C-UV - Comexim Matérias Primas Ltda, São Paulo, Brasil) ou ao armazenamento em fluorfosfato acidulado a 1,23%. A rugosidade superficial foi realizada em rugosímetro SJ - 201P (Mitutoyo, Tokyo, Japão) em dois momentos: inicial (R1) foi aquela mensurada logo após obtidos os corpos-de-prova e a rugosidade superficial final (R2) aquela obtida após o envelhecimento artificial acelerado ou armazenamento em fluorfosfato acidulado a 1,23%. Para verificar as alterações de cor ocorridas nas cerâmicas odontológicas utilizou-se o Espectrofotômetro PCB 6807 BYK GARDNER (Columbia, Estados Unidos). Foram feitas leituras antes e após as etapas de envelhecimento artificial acelerado e armazenamento em fluorfosfato acidulado a 1,23%. Os resultados médios e desvios padrão para os corpos-de-prova livre de metal com envelhecimento artificial acelerado foram: a) rugosidade superficial: Triceram antes 0,390 ± 0,097, após 0,431 ± 0,100; Noritake Ti 22 antes 0,299 ± 0,075, após 0,312 ± 0,076; b) alteração de cor: Triceram 0,28 ± 0,14; Noritake Ti 22 0,33 ± 0,22; e para os corpos-de-prova submetidos ao armazenamento em fluorfosfato acidulado a 1,23% foram: a) rugosidade superficial: Triceram antes 0,325 ± 0,036 , após 2,199 ± 0,889; Noritake Ti 22 antes 0,317 ± 0,094, após 2,760 ± 0,833; b) alteração de cor: Triceram 5,39 ± 1,61; Noritake Ti 22 7,31 ± 0,71. Para as amostras metalocerâmicas com envelhecimento artificial acelerado foram: a) rugosidade superficial: Triceram antes 0,282 ± 0,06, após 0,315 ± 0,095; Noritake Ti 22 antes 0,269 ± 0,062, após 0,290 ± 0,075; b) alteração de cor: Triceram 0,57 ± 0,11; Noritake Ti 22 0,41 ± 0,08; e para os corpos-de-prova submetidos ao armazenamento em fluorfosfato acidulado a 1,23% foram: a) rugosidade superficial: Triceram antes 0,137 ± 0,026, após 2,560 ± 0,377; Noritake Ti 22 antes 0,125 ± 0,34, após 3,174 ± 0,565; b) alteração de cor: Triceram 7,56 ± 1,21; Noritake Ti 22 7,69 ± 1,26. Os resultados obtidos mostraram que o envelhecimento artificial acelerado simulando dez anos de uso clínico da restauração não afetou a rugosidade superficial de nenhuma das cerâmicas avaliadas, em nenhum grupo; que apenas o grupo da cerâmica Triceram com subestrutura em titânio comercialmente puro revelou valores de &Delta;E estatisticamente maiores que os demais, revelando que o envelhecimento artificial acelerado influenciou a coloração desse grupo. Entretanto, a alteração de cor apresentou-se menor que um, sendo considerada clinicamente indetectável; que após o armazenamento em fluorfosfato acidulado foi observado aumento de rugosidade superficial semelhante estatisticamente para ambas as cerâmicas estudadas, tanto em amostras livres de metal quanto metalocerâmicas; que a alteração total de cor, após armazenamento em fluorfosfato acidulado, todos os grupos revelaram valores inaceitáveis clinicamente (&Delta;E > 3,3) / The purpose of this study was to evaluate the influence of accelerated artificial aging and of 1.23% acidulated phosphate fluoride over superficial roughness and color stability of two low-fusing dental ceramics for titanium (Triceram- Dentaurum, and Noritake Ti22- Noritake), metal-free or metalceramics using commercially pure titanium (Tritan- Dentaurum). 80 cylindrical samples, with 15mm of diameter and 2.5mm of thickness, being 40 for each ceramic, 20 metal free and 20 metal-ceramics, which were divided into two groups of 10 samples, being submitted to the accelerated artificial aging (System Accelerated of Aging for not-metallic C-UV - Comexim Raw materials Ltda, São Paulo, Brazil) or storage in 1.23% acidulated phosphate fluoride. Superficial roughness was accomplished by roughness tester SJ - 201P (Mitutoyo, Tokyo, Japan) in two moments: initial measured after obtained the samples and final superficial roughness after the accelerated artificial aging or storage in 1.23% acidulated phosphate fluoride. Color changes were analyzed by a spectrophotometer PCB 6807 BYK GARDNER (Columbia, United States). The average results and standard deviations for the metal free over accelerated artificial aging were: a) superficial roughness: Triceram before 0.390 ± 0.097, after 0.431 ± 0.100; Noritake Ti22 before 0.299 ± 0.075, after 0.312 ± 0.076; b) color evaluation: Triceram 0.28 ± 0.14; Noritake Ti22 0.33 ± 0.22; and for samples submitted to the storage in 1.23% acidulated phosphate fluoride were: a) superficial roughness: Triceram before 0.325 ± 0.036, after 2.199 ± 0.889; Noritake Ti22 before 0.317 ± 0.094, after 2.760 ± 0.833; b) Color evaluation: Triceram 5.39 ± 0.61; Noritake Ti22 7.31 ± 0.71. The data were submitted to ANOVA and Duncan statistics analysis to p &le; .05. The obtained results showed that the accelerated artificial aging simulating ten years of clinical use of the restoration did not affect the superficial roughness of none of the evaluated ceramics, in no group; which only the group of the Triceram with substructure in commercially pure titanium revealed values statistically greater than the rest, revealing that the accelerated artificial aging influenced the color of this group. However, the values of color alteration was smaller than 1, being considered clinically acceptable ; which after the storage in 1.23% acidulated phosphate fluoride was observed increased values of superficial roughness with significant difference between both studied ceramics, as in metal-free samples as in metal-ceramics; which the color alteration, after storage in 1.23% acidulated phosphate fluoride, revealed to all the groups evaluated unacceptable values clinically (&Delta;E > 3.3).

Page generated in 0.6702 seconds