Spelling suggestions: "subject:"esgoto - delineamento""
1 |
Adenovirus e rotavirus como indicadores biologicos em aguas residuarias de esgotos sanitarios apos tratamento por processo anaerobio e disposição controlada no solo / Adenoviruses as biological indicators in watewater from sewage, before anaerobic process treatment and soil disposalMartins, Sandra Soares 09 August 2018 (has links)
Orientador: Maria Silvia Viccari Gatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-09T22:09:52Z (GMT). No. of bitstreams: 1
Martins_SandraSoares_M.pdf: 1140484 bytes, checksum: de8846c9246eef9258a4b0d3953a88b6 (MD5)
Previous issue date: 2006 / Resumo: O tratamento de esgoto sanitário em lagoa de decantação anaeróbia e disposição controlada de água residuária no solo é uma alternativa de baixo custo para o reuso de águas residuárias na agricultura. Nele, o esgoto sanitário é depositado em uma lagoa de decantação anaeróbia com retenção hidráulica de sete dias, após o que a água residuária é conduzida para rampa de solo franco argilo-arenoso, com cobertura vegetal de gramínia Cynodon sp, para disposição por escoamento superficial, seguindo-se sua infiltração e percolação. O objetivo desse trabalho foi verificar a eficiência desse sistema na eliminação e/ou inativação de adenovírus humanos (HAdV) e rotavírus (RV). Amostras de 1L de água residuária foram obtidas em quatro coletas, em intervalos de sete dias, na entrada do esgoto bruto (EB), no ponto de aplicação na rampa (0m) e nos pontos da sua superfície após 10, 20, 30, 35m e 40m. Sob a rampa, a 1m de profundidade e distantes 30m (30-1) e 35m (35 -1), dois pontos foram amostrados. Antes do ponto 0m, pontos de testemunha a 1m de profundidade e distantes 2m (T1) e 0,5m (T2) da rampa, e um ponto do lençol freático (LF) a 3m de profundidade, também foram coletados.As água residuárias foram concentradas de 1.000 a 5.000 vezes por filtração e eluição em membrana eletropositiva e ultracentrifugação. Nos eluatos obtidos, após extração de DNA, a presença de HAdV foi pesquisada por PCR e nested-PCR. Para a detecção de RV usou-se RT-PCR e duplo-semi- nested-PCR. Eluatos HAdV positivos foram inoculados em células HEp-2 e após até cinco passagens a presença de HAdV foi confirmada por PCR.. HAdV foram detectados em 29 das 35 amostras analisadas, sendo positivos todos os pontos de EB e da superfície da rampa. Em profundidade, sob a rampa, quatro amostras foram positivas, além de outras duas em T2 e uma em LF, o que demonstra a percolação desses vírus no solo com contaminação do LF. Quando testadas em células HEp-2, nas amostras do EB e dos pontos 0, 30, 35 e 40m a presença de vírions foi determinada, enquanto nos pontos 30-1m e LF os HAdV não foram infectivos. Esses resultados permitem concluir que o sistema não foi eficiente para remover e/ou inativar HAdV. Por outro lado, pode-se afirmar que os HAdV são indicadores virais adequados para esse sistema, desde que mantida a metodologia aqui empregada. Uma amostra de EB foi positiva para RV (genotipos G1 e G2), resultado esse que não permite qualquer conclusão. Para o reuso da água residuária advinda desse sistema impõe-se a associação de processos de desinfecção para a eliminação de HAdV / Abstract: Urban sewage treatment by an anaerobic process with overland flow system is a cheap alternative to reuse domestic effluents in agriculture. In this procedure, wastewater remains in an anaerobic pond for seven days, and then it is spilled from the top of a 40-meter extension slope covered with Tifton 85 (Cynodon sp) grass in order to surface flow and percolate until it reaches groundwater. The objective of this work is to determine if this procedure could be effective in removing and/or inactivating human adenoviruses (HAdV) and rotaviruses (RV) in a test unit in Limeira - SP, Brazil. Samples were collected every seven days from different spots in four sampling events totalizing one liter of wastewater. Sampling points were chosen at the raw sewage (EB), on the surface of the slope at 0, 10, 20, 30, 35 and 40 meters, and down one meter from the surface of the slope at the 30- and 35-meter points (30-1 and 35-1). Other points upslope were used at a distance of 2 meters (T1) and 0.5 meters (T2), beyond a 3-meter depth and 1-meter distant spot (LF). All samples were concentrated from a 1000 to 5000 times by filtration through electropositive microporous membrane followed by ultracentrifugation. HAdV detection was performed by both PCR and nested PCR. RV detection was accomplished by both RT-PCR and duplex semi-nested PCR. The positive samples for HAdV were inoculated in HEp-2 cells, and confirmation of the virions was performed by PCR. HAdV were detected in 29 of the 35 samples tested including in all samples both from the EB and from the surface of the slope. HAdV tested positive in the two T2, in one LF, and in the four samples underneath the slope. In HEp-2 cells HAdV virions were detected at the EB and at 0, 30, 35, and 40 meters on the surface of the slope. Spots 30-1 and LF were tested in HEp-2 cells, resulting negative to the presence of infective viral particles, although they tested HAdV positive. These results attest to the inefficiency of the proposed system of sewage treatment in removing and/or inactivating HAdV; however, maintaining the methodology used in this research, HAdV proves to be the appropriate viral indicator in this system. In relation to RV, no conclusions can be extracted since just one sample from the EB was RV-positive (G1 and G2 mixture). Finally, before reuse in agriculture, the effluents from the anaerobic pond should be disinfected to eliminate these viruses / Mestrado / Microbiologia / Mestre em Genética e Biologia Molecular
|
2 |
Pos-tratamento de efluente anaerobio por filtros de areia / Post-treatment of anaerobic reactor effluent by sand filtersTonetti, Adriano Luiz, 1973- 13 February 2004 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T21:31:46Z (GMT). No. of bitstreams: 1
Tonetti_AdrianoLuiz_M.pdf: 4911696 bytes, checksum: 17f72ad475f9781c9cc0c2be169415a9 (MD5)
Previous issue date: 2004 / Resumo: O objetivo deste projeto foi estudar os filtros de areia como um método de baixo custo para o pós-tratamento de filtros anaeróbios alimentados com esgoto sanitário. Nesta pesquisa buscou-se contribuir com o desenvolvimento deste sistema avaliando-se a eficiência de tratamento de quatro filtros de areia com diferentes profundidades de leitos (0,25; 0,50, 0,75 e 1,00 m). A alimentação era proveniente de reatores anaeróbios e foram empregadas cinco cargas diferentes de aplicação (20, 40, 60, 80 e 100 Lm-2). Cada uma delas dispostas diariamente pelo período de um mês.
O esgoto bruto, afluente e efluente dos filtros de areia foram analisados semanalmente, permitindo constatar que no emprego de baixas cargas de efluente anaeróbio o sistema propiciava uma remoção superior a 96% da DBO, adequação na emissão de coliformes totais e completa nitrificação. Aumentando-se as cargas, ocorria uma pequena redução da eficiência, no entanto os resultados ainda eram satisfatórios / Abstract: The aim of this project was to study sand filters as a low cost method in the post treatment of upflow anaerobic filter effluent, fed by municipal wastewater. This research intends to contribute with the development of this system estimating the efficiency of the treatment of four sand filters with different depths of the sand layer (0,25; 0,50, 0,75 e 1,00 m). The feed (I think it's influent) was from the four upflow anaerobic filters. Five hydraulic loads (20, 40, 60, 80 e 100 Lm-2) were used to apply the effluent on the sand filters. Each one was applied for one month and later the
frequency was increased for two and tree times per day. The municipal wastewater, influent and the effluent of the sand filter were weekly analyzed allowing to conclude that the treatment system had good removal of BOD, COD, TOC, nutrients and microorganisms like total and fecal coli forms. The
effluent was good to be disposed or to reused. / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
3 |
Remoção de helmintos e protozoarios em sistema de tratamento filtro anaerobio- filtro de areia visando uso agricola / Helminths and protozoans removal in treatment of anaerobic filter- sand filter system focusing agricultural useKanegae, Alexandre Patto 17 March 2005 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T15:44:03Z (GMT). No. of bitstreams: 1
Kanegae_AlexandrePatto_M.pdf: 1125389 bytes, checksum: dc519b3abb15e2a72d094f64448f7383 (MD5)
Previous issue date: 2005 / Resumo: Este trabalho foi desenvolvido com o intuito de se verificar a utilização de filtros de areia, como um sistema de pós-tratamento de efluentes de filtros anaeróbios na remoção de organismos patogênicos presentes nos esgotos, tais como protozoários e helmintos. Para tanto, foi feita a verificação das melhores taxas de aplicação de efluente de filtro anaeróbio em 4 filtros de areia, com profundidades de 0,25; 0,50; 0,75 e 1,00 m. As taxas de aplicação foram de 20, 40, 60, 80 e 100 Lm-2dia -1. O tempo do experimento foi de Maio de 2003 a Agosto de 2004. Para verificação dos organismos presentes no efluente utilizou-se a metodologia adotada pela Cetesb, descrita pela norma L5.550 (1989) - Hoffman modificado e os resultados foram expressos em número de organismos/L. Os resultados demonstraram que o processo de tratamento biológico ocorrido nos filtros de areia com leito mais profundo (1,00 m) foi o que apresentou melhor performance. Não houve correlação entre o número de organismos encontrados e as taxas aplicadas, mas o valor estipulado pela NBR 7229 (1993) de 100 Lm-2dia-1 de efluente aplicado, apresentou resultados satisfatórios / Abstract: This project was developed with the aim of verifying the use of sand filters as a post treatment system of effluents from anaerobic filters. Most of the pathogens found in the wastewater can be classified as protozoans and helminths. For that, the best application rates of anaerobic effluent were studied in four sand filters. They were 0,25; 0,50; 0,75 and 1,00 m deep. The application rates were 20, 40,60,80 e 100 Lm-2day-1. The experiment was run from May 2003 to August 2004. To verify the presence of the organisms in the wastewater, the methodology adopted by Cetesb was used (described as Standard L5.550, 1989) - Hoffman modified and the results were expressed in number or organisms/L. The results show that the biological process of treatment occurred in the deepest sand filter (1,00 m) was the one which presented the best performance. There was no correlation between the number of microorganisms found and the applied rates but, the value established by NBR 7229 (1993) of 100 Lm-2day-1 of effluent presented satisfactory results / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
4 |
Avaliação das valas de filtração como metodo de pos-tratamento de efluente anaerobico : remoção natural de patogenos e nutrientes na aplicação de altas taxas hidraulicas / Evaluation of filtration ditches as method of post treatment of effluent anaerobic : removal natural of pathogens and nutrients in application of high hydrauli ratesSousa Junior, Oder Luiz de, 1977- 31 August 2006 (has links)
Orientadores: Bruno Coraucci Filho, Roberto Feijo de Figueiredo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-11T17:07:18Z (GMT). No. of bitstreams: 1
SousaJunior_OderLuizde_M.pdf: 3018467 bytes, checksum: f62050928dc0c085881f96c0708b1328 (MD5)
Previous issue date: 2006 / Resumo: O objetivo deste projeto foi estudar as valas de filtração como um método de baixo custo aplicável a residências isoladas e pequenas ou médias comunidades brasileira, analisar as valas de filtração como unidades de pós-tratamento de efluente anaeróbio de um sistema fossa filtro, na remoção natural de nutrientes e microrganismos patogênicos. No presente estudo foram estudadas três valas de filtração em escala piloto com 1 m de comprimento e 0,50 m de largura, com altura da camada de areia igual a 0,25, 0,50, e 0,75 m, foi utilizado tubo de drenagem em PEAD - polietileno de alta densidade ¿ com 0,10 m de diâmetro, as valas de filtração foram alimentadas por efluente de um sistema fossa filtro, foram empregadas 4 taxas hidráulicas (40, 60, 80, e 100 L/m2.dia) cada taxa foi aplicada na freqüência de 6, 12, 18, e 24 hora/dia. O esgoto bruto, afluente, e efluente das valas de filtração, foram analisados semanalmente permitindo constatar que os resultados obtidos no estudo das valas de filtração no emprego de altas taxas hidráulicas proporcionavam uma remoção superior a 82,5% DBO e adequação de coliformes e a ausência de microrganismo patogênico. Quanto aos compostos nitrogenados, ocorreu uma grande nitrificação. A concentração de fósforo também foi muito reduzida, adequando o efluente das valas de filtração a legislação brasileira, em todas as taxas empregadas / Abstract: The aim of this work was to study filtration ditches as a method of low cost applicable the isolated homes and the small Brazilian municipalities for the posttreatment of anaerobic effluent from a system septic tank with anaerobic unit in the removal of natural nutrients and pathogenic microorganisms. For the research were analyzed three filtration ditches on pilot-scale with 1 m length and 0,5 m width, with height of the layer of sand equal 0,25, 0,50, and 0,75 m was used a drainage pipe in HDPE - High Density Polyethylene - with 0,10 m in diameter. The of filtration ditches were fed by effluent from a system septic tank with anaerobic unit were used four high hydraulic rates (40, 60, 80, and 100 L/m2.day) each rate was applied in the frequency of 6, 12, 18, and 24 hours/day. The municipal wastewater, affluent and the effluent of the filtration ditches were weekly analyzed allowing that the results obtained in the study removal of organic matter exceeded 82,5% BOD and adequacy of coliform, absence of pathogenic microorganisms. In terms of nitrogen compounds, a high nitrification occurred. The phosphorus concentration also was very reduced, the effluent of the three filtration ditches being in compliance with Brazilian laws at all the rates used. / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
Page generated in 0.0586 seconds