• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparação biomecânica entre CRIF e placa de reconstrução utilizadas para estabilização de fraturas distais de fêmur de cães / Biomechanical comparison of CRIF and reconstruction plate for stabilization of distal femur fractures in dogs

Paes, Fernanda 25 October 2016 (has links)
O presente estudo objetivou comparar biomecanicamente, por meio do ensaio de compressão excêntrica, a resistência dos implantes Clamp and Rod Internal Fixation (CRIF) 5,0 mm versus placa de reconstrução 3,5 mm na fixação de fratura distais de fêmur de cão. Tais implantes foram subdividos em dois grupos, denominados grupo CRIF (GC) e grupo placa (GC). Foram utilizados 22 fêmures de 10 cadáveres de cão entre 2 e 7 anos de idade e peso corporal entre 20 e 40 kg, que foram distribuídos aleatoriamente a serem testados ambos os implantes em cada um dos membros dos pares. Para realização dos testes, foi simulado uma fratura distal nos corpos de prova, através de uma osteotomia de até 0,5 cm, realizada por meio de serra oscilatória, imediatamente proximal ao início da tróclea. Os implantes foram fixados segundo os padrões AOSIF, lateralmente ao fêmur, sendo utilizados três parafusos distais e cinco proximais ao foco de fratura. Foi utilizado o programa de computador PMI para calcular o ponto máximo de resistência antes da falha e avaliadas as variáveis força máxima, deformação máxima real, rigidez, força intermediária e deformação intermediária real. Não foram encontradas diferenças estatisticamente significativas entre os GC e GP quantos as variáveis avaliadas / This study aims to compare the biomechanical properties, through eccentric compression test, of the resistance of the 5.0 mm Clamp and Rod Internal Fixation Implants (CRIF) and 3.5 mm reconstruction plate in fixing dog femur distal fracture. Such implants were subdivided into two groups, called CRIF Group (CG) and plate group (CG). It was used 22 femurs from 11 dog cadavers with age between 2 and 7 years old and body weight between 20 and 40 kg, which was randomly assigned to test both implants in each member of the pair. A distal fracture in the specimens with a gap of 0.5 cm osteotomy, it was simulated to perform the test, performed by the oscillating saw, just proximal to the beginning of the trochlea. Bound the distance from the gap to the distal femur limit was equivalent to the distance between the femoral condyles. The implants were fixed by the standards AO / SIF, laterally to the femur, being used three distal screws and five proximal to the fracture site. The bone was placed longitudinally, and the femoral neck coupled to a concave surface simulating an acetabular device. PMI computer program was used to calculate the maximum point of resistance before failure and evaluated the variables maximum strength, real maximum deformation, stiffness, intermediate strength and real intermediate deformation. No statistically significant differences were found between the GC and GP as the variables evaluated
2

Comparação biomecânica entre CRIF e placa de reconstrução utilizadas para estabilização de fraturas distais de fêmur de cães / Biomechanical comparison of CRIF and reconstruction plate for stabilization of distal femur fractures in dogs

Fernanda Paes 25 October 2016 (has links)
O presente estudo objetivou comparar biomecanicamente, por meio do ensaio de compressão excêntrica, a resistência dos implantes Clamp and Rod Internal Fixation (CRIF) 5,0 mm versus placa de reconstrução 3,5 mm na fixação de fratura distais de fêmur de cão. Tais implantes foram subdividos em dois grupos, denominados grupo CRIF (GC) e grupo placa (GC). Foram utilizados 22 fêmures de 10 cadáveres de cão entre 2 e 7 anos de idade e peso corporal entre 20 e 40 kg, que foram distribuídos aleatoriamente a serem testados ambos os implantes em cada um dos membros dos pares. Para realização dos testes, foi simulado uma fratura distal nos corpos de prova, através de uma osteotomia de até 0,5 cm, realizada por meio de serra oscilatória, imediatamente proximal ao início da tróclea. Os implantes foram fixados segundo os padrões AOSIF, lateralmente ao fêmur, sendo utilizados três parafusos distais e cinco proximais ao foco de fratura. Foi utilizado o programa de computador PMI para calcular o ponto máximo de resistência antes da falha e avaliadas as variáveis força máxima, deformação máxima real, rigidez, força intermediária e deformação intermediária real. Não foram encontradas diferenças estatisticamente significativas entre os GC e GP quantos as variáveis avaliadas / This study aims to compare the biomechanical properties, through eccentric compression test, of the resistance of the 5.0 mm Clamp and Rod Internal Fixation Implants (CRIF) and 3.5 mm reconstruction plate in fixing dog femur distal fracture. Such implants were subdivided into two groups, called CRIF Group (CG) and plate group (CG). It was used 22 femurs from 11 dog cadavers with age between 2 and 7 years old and body weight between 20 and 40 kg, which was randomly assigned to test both implants in each member of the pair. A distal fracture in the specimens with a gap of 0.5 cm osteotomy, it was simulated to perform the test, performed by the oscillating saw, just proximal to the beginning of the trochlea. Bound the distance from the gap to the distal femur limit was equivalent to the distance between the femoral condyles. The implants were fixed by the standards AO / SIF, laterally to the femur, being used three distal screws and five proximal to the fracture site. The bone was placed longitudinally, and the femoral neck coupled to a concave surface simulating an acetabular device. PMI computer program was used to calculate the maximum point of resistance before failure and evaluated the variables maximum strength, real maximum deformation, stiffness, intermediate strength and real intermediate deformation. No statistically significant differences were found between the GC and GP as the variables evaluated
3

As expressões vivas de corpos idosos frente à queda / The living expressions of elderly bodies face to fall

Rosa, Ana Elisa Sena Klein da 03 February 2012 (has links)
Made available in DSpace on 2016-04-27T18:47:08Z (GMT). No. of bitstreams: 1 Ana Elisa Sena Klein da Rosa.pdf: 1325679 bytes, checksum: ff0ceea43091284f2a08c54cdfbf60d9 (MD5) Previous issue date: 2012-02-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The relationship of the body in old age is very particular to each individual. Norbert Elias (2001) discussed the difficulty that our own body, so full of freshness and often pleasant sensations, can be slow, tired and clumsy. We cannot imagine it, and basically we do not want it. The fall followed by femoral fracture causes huge strangeness, an image in which the elder cannot identify himself, resulting in a disconnection between the image of the unconscious of the body and the image that the mirror gives him back. The objective of this study was to delineate the socio-demographic profile of 40 elders (31 females and 9 males) with femur fracture in surgical indication for pre operative phase, attended by the Service of Orthopedics of the Hospital of the State Public Servant of São Paulo (HSPESP). It is a cross-sectional observational study, and the data were collected through visits to files of medical records and semi-structured interviews, during the period of October 2010 to February 2011. All statistical analyzes were performed by SPSS for Windows, version 15.0. The age of the subjects studied ranged from 62 to 97 years old, with an average age equal to 78.9 years old, 77.5% were female, and 72.5% cared by a family caregiver. A factor of extreme relevance was that 97.5% of the subjects use more than 3 concomitant medicines daily. These and many others facts were raised with the intention of cross factors that reflect in the trial of human ageing. For the Gerontology, old age is to be understood by different looks. The social, cultural and subjective aspects permeate and intertwine in old age. With this study was possible to notice that a public health policy is necessary for that the rate of falls can be reduced by taking actions which are intended to give the elderly a better self-awareness of his body, and identify situations that can be harmful in relation to increase the risk of falls / A percepção sobre o corpo na velhice é muito particular para cada ser. A esse respeito, Norbert Elias (2001) discorre sobre a dificuldade sentida pelas pessoas quando seus corpos, tão cheios de frescor e muitas vezes de sensações agradáveis, passam a ficar vagarosos, cansados e desajeitados. Não se pode imaginar tal mudança e, no fundo, não se quer. Nesse sentido, a queda acompanhada de fratura femoral causa enorme estranheza, pois há uma imagem com a qual o idoso não se identifica, ocorrendo uma desconexão entre a imagem do inconsciente do corpo e a imagem que o espelho devolve-lhe. O objetivo deste estudo foi traçar o perfil sociodemográfico de 40 idosos (31 do sexo feminino e nove do sexo masculino) com fratura de fêmur, em indicação de tratamento cirúrgico em fase pré-operatória, atendidos pelo Serviço de Ortopedia do Hospital do Servidor Público Estadual de São Paulo. Trata-se de um estudo observacional de corte transversal, com coleta de dados através de visita a arquivos de prontuários médicos e entrevistas semiestruturadas, no período de outubro de 2010 a fevereiro de 2011. Todas as análises estatísticas foram feitas pelo Software Statistical Package for the Social Sciences para Windows, na versão 15.0. A idade dos sujeitos estudados variou de 62 a 97 anos, com média de idade de 78,9 anos, prevalecendo 77,5% do sexo feminino, e 72,5% dos idosos eram cuidados por um cuidador familiar. Um fator de extrema relevância foi que 97,5% dos sujeitos faziam uso de mais de três medicamentos concomitantes diariamente. Esses e muitos outros dados foram levantados com o intuito de cruzar fatores que incidem no processo de envelhecimento humano, pois, para a Gerontologia, a velhice deve ser entendida sob diferentes olhares, uma vez que os aspectos sociais, culturais e subjetivos permeiam e se entrelaçam na velhice. Com este estudo, foi possível notar que uma política de saúde pública faz-se necessária, com o desenvolvimento de ações que tenham como finalidade proporcionar ao idoso um melhor autoconhecimento de seu corpo, assim como identificar situações que possam lhe ser prejudiciais em relação ao maior risco de quedas, para que o índice de quedas possa ser reduzido

Page generated in 0.0236 seconds