• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de emissões fugitivas de biogás na camada de cobertura do aterro sanitário da CTR de Nova Iguaçu e do Lixão de Seropédica, Rio de Janeiro. / Monitoring and evaluation of biogas emission through the final cover layer of the waste treatment center of Nova Iguaçu and Dump of Seropédica, Rio de Janeiro.

Ana Carolina Eugênio de Oliveira 17 April 2013 (has links)
No Brasil, se espera ter até 2014, de acordo com o prazo da Política Nacional de Resíduos Sólidos, todos os lixões erradicados e os resíduos sólidos urbanos gerados depositados em aterros sanitários. Atualmente, os projetos de aterros sanitários dão oportunidade para um nicho de mercado, o da fonte de geração de energia. Um parâmetro de controle da poluição do ar causada pelos aterros sanitários são as chamadas camadas de cobertura. Nesse contexto, é de fundamental importância o estudo de camadas de cobertura de resíduos por ser um importante elemento de projeto para evitar ou minimizar a poluição do ar devido aos gases gerados em aterros sanitários de resíduos sólidos, já que é o elo existente entre o ambiente interno dos resíduos e a atmosfera. A presente pesquisa aborda o comportamento dos gases em relação à camada de cobertura existentes na CTR de Nova Iguaçu e no Lixão remediado de Seropédica. Foram realizados ensaios de Placa de Fluxo, medição de pressão e concentração dos gases no contato solo-resíduo e emissões dos gases pelos drenos, além das análises de solo in situ e em laboratório. Os ensaios foram realizados de outubro a novembro de 2012. Os resultados indicaram uma inexistência de fluxo de gases pela camada de cobertura, que possui 1,10 m de espessura, do lixão de Seropédica, sendo encontrado apenas fluxo nos drenos. Na CTR Nova Iguaçu, foi verificada que praticamente a inexistência de fluxo de gases com o sistema de gás ligado, mesmo possuindo uma camada de cobertura de 0,8 m. / In Brazil, according to the timeframe given by the National Policy of Solid Waste, by 2014, every dump will be eradicated and every municipal solid waste generated will be deposited in landfills. Currently, the landfill projects provide an opportunity for the market, which is a source of energy. A parameter of control of the air pollution caused by landfills is called cover layers. In this context, it is important the study of the cover layers to avoid or minimized the air pollution due to gases generated in landfills, which is the link between the solid waste and the atmosphere. This research addresses the behavior of the gases in relation to the cover layers on the CTR Nova Iguaçu and Dump of Seropédica. Six test trials of the Flux chamber, pressure measurement and concentration of gases in the soil-residue contact and emissions of gases through the drains, in addition to in situ soil analysis and laboratory analysis. The tests trials were performed from October, 2012 to November, 2012. The results indicated no gas flow through the cover layer, which has a thickness of 1.10 m, of the dump of Seropédica, where the gas flow was only encountered through the drains. In CTR Nova Iguaçu, the gas flow was almost inexistent, even having a cover layer of thickness of 0.8 m.
2

Avaliação de emissões fugitivas de biogás na camada de cobertura do aterro sanitário da CTR de Nova Iguaçu e do Lixão de Seropédica, Rio de Janeiro. / Monitoring and evaluation of biogas emission through the final cover layer of the waste treatment center of Nova Iguaçu and Dump of Seropédica, Rio de Janeiro.

Ana Carolina Eugênio de Oliveira 17 April 2013 (has links)
No Brasil, se espera ter até 2014, de acordo com o prazo da Política Nacional de Resíduos Sólidos, todos os lixões erradicados e os resíduos sólidos urbanos gerados depositados em aterros sanitários. Atualmente, os projetos de aterros sanitários dão oportunidade para um nicho de mercado, o da fonte de geração de energia. Um parâmetro de controle da poluição do ar causada pelos aterros sanitários são as chamadas camadas de cobertura. Nesse contexto, é de fundamental importância o estudo de camadas de cobertura de resíduos por ser um importante elemento de projeto para evitar ou minimizar a poluição do ar devido aos gases gerados em aterros sanitários de resíduos sólidos, já que é o elo existente entre o ambiente interno dos resíduos e a atmosfera. A presente pesquisa aborda o comportamento dos gases em relação à camada de cobertura existentes na CTR de Nova Iguaçu e no Lixão remediado de Seropédica. Foram realizados ensaios de Placa de Fluxo, medição de pressão e concentração dos gases no contato solo-resíduo e emissões dos gases pelos drenos, além das análises de solo in situ e em laboratório. Os ensaios foram realizados de outubro a novembro de 2012. Os resultados indicaram uma inexistência de fluxo de gases pela camada de cobertura, que possui 1,10 m de espessura, do lixão de Seropédica, sendo encontrado apenas fluxo nos drenos. Na CTR Nova Iguaçu, foi verificada que praticamente a inexistência de fluxo de gases com o sistema de gás ligado, mesmo possuindo uma camada de cobertura de 0,8 m. / In Brazil, according to the timeframe given by the National Policy of Solid Waste, by 2014, every dump will be eradicated and every municipal solid waste generated will be deposited in landfills. Currently, the landfill projects provide an opportunity for the market, which is a source of energy. A parameter of control of the air pollution caused by landfills is called cover layers. In this context, it is important the study of the cover layers to avoid or minimized the air pollution due to gases generated in landfills, which is the link between the solid waste and the atmosphere. This research addresses the behavior of the gases in relation to the cover layers on the CTR Nova Iguaçu and Dump of Seropédica. Six test trials of the Flux chamber, pressure measurement and concentration of gases in the soil-residue contact and emissions of gases through the drains, in addition to in situ soil analysis and laboratory analysis. The tests trials were performed from October, 2012 to November, 2012. The results indicated no gas flow through the cover layer, which has a thickness of 1.10 m, of the dump of Seropédica, where the gas flow was only encountered through the drains. In CTR Nova Iguaçu, the gas flow was almost inexistent, even having a cover layer of thickness of 0.8 m.
3

CARACTERIZAÇÃO METROLÓGICA DE UM MEDIDOR VOLUMÉTRICO PARA PEQUENAS TAXAS DE FLUXO DE GÁS UTILIZANDO O MÉTODO DE DIFERENÇA DE PRESSÃO / CHARACTERIZATION OF A GAUGE METROLOGICAL VOLUMETRIC FOR SMALL FLOW RATE OF GAS USING THE METHOD PRESSURE DIFFERENCE

Abreu, Pedro Augusto Lopes 16 March 2011 (has links)
Made available in DSpace on 2016-08-17T14:53:15Z (GMT). No. of bitstreams: 1 Pedro Augusto Lopes Abreu.pdf: 1389353 bytes, checksum: 81ce9ae4d3b6d093a60100d28069418b (MD5) Previous issue date: 2011-03-16 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A system for measuring low rates of gas flow has great importance for some industrial and especially for scientific applications where usually high accuracy and low uncertainty are required. This type of measurement systems have undergone a great development in recent years primarily due to the concern with the release of gases in natural processes occurring in the environment, such as anaerobic biodegradation process which releases methane and the use in the production of biogas. In this work, the development of low-volume gas flow rate measurement system using the method of pressure difference in a container of known volume is presented. A microcontroller is used to control two valves located one gas inlet and the other at the gas outlet of the container. Appropriate analysis of uncertainty propagation is carried out, and components suitable are selected for the development of the meter in order to perform the measurement with low uncertainty. Simulations and experimental tests are presented for validating the proposed system. / Os sistemas de medição de pequenas taxas de fluxo de gás tem grande relevância nos âmbitos industriais e científicos, nos quais suas aplicações exigem geralmente medições com baixa incerteza. Esses sistemas de medição tem tido uma grande evolução ultimamente. Isso se deve, principalmente, à preocupação com a liberação de gases em processos biológicos naturais como, por exemplo, o gás metano liberado no processo de biodegradação anaeróbio, e que também é aproveitado como biogás. Neste trabalho, apresenta-se o desenvolvimento de um medidor para pequenos volumes de gases utilizando o método de diferença de pressão em um recipiente de volume conhecido. Um microcontrolador é utilizado no controle das duas válvulas localizadas na entrada e na saída do recipiente. São realizados estudos apropriados de análise e propagação de incertezas, e são escolhidos componentes adequados para o desenvolvimento e construção do medidor, de modo a realizar a medição com boa exatidão e baixa incerteza. Simulações e testes experimentais são apresentados para validação do sistema proposto.
4

Fluxos de amônia e óxido nitroso na interface ar-água do sistema lagunar de Maricá-Guarapina

Couto, Vanessa Barcelos 16 May 2017 (has links)
Submitted by Biblioteca de Pós-Graduação em Geoquímica BGQ (bgq@ndc.uff.br) on 2017-05-16T17:00:09Z No. of bitstreams: 1 Microsoft Word - Vanessa Dissertaçao.pdf: 1678884 bytes, checksum: ee88f8d0505bb8844a68dc56e1473779 (MD5) / Made available in DSpace on 2017-05-16T17:00:09Z (GMT). No. of bitstreams: 1 Microsoft Word - Vanessa Dissertaçao.pdf: 1678884 bytes, checksum: ee88f8d0505bb8844a68dc56e1473779 (MD5) / Universidade Federal Fluminense. Instituto de Química. Programa de Pós-Graduação em Geoquímica, Niterói, RJ / Este estudo analisa os fluxos de óxido nitroso (N 2 O) e amônia (NH 3 ) no Sistema Lagunar de Maricá-Guarapina (SLMG). O N 2 O é um dos gases do efeito estufa e está envolvido no consumo de ozônio (O 3 ) na estratosfera. A NH 3 pode levar a acidificação de ambientes terrestres e aquáticos, a eutrofização de sistemas aquáticos e produção de N 2 O. O SLMG vem sofrendo degradação da qualidade de suas á guas devido à urbanização e às atividades agropecuárias na região. Este sistema la gunar é composto por quatro lagoas interligadas entre si através de canais: Maricá, Ba rra, Padre e Guarapina. Para a análise de N 2 O foi utilizada a técnica da câmara estática flutua nte e 4 modelos de predição de fluxos (MPF). No caso da NH 3 foram feitas estimativas de fluxos também através de MPF. Os resultados deste estudo mostram que as quatro lagoa s do SLMG apresentam comportamentos distintos com relação aos fluxos dos dois gases ana lisados. As estimativas de taxas de emissão do sistema lagunar mostram que, apesar do sistema a presentar lagoas que parecem atuar como sorvedouro de N 2 O ou de NH 3 , num balanço geral, ele emite N para a atmosfera s ob uma ou outra forma. A taxa de emissão estimada variou entr e 92,15 g N dia -1 e 104,77 g N dia -1 . Outra informação que esta estimativa trouxe foi a d e que a maior parte das emissões ocorre sob a forma de NH 3 com emissão estimada de 84,79 g N dia -1 a 97,41 g N dia -1 . / This study examines the nitrous oxide (N 2 O) and ammonia (NH 3 ) fluxes in Maricá- Guarapina’s system. The N 2 O is a greenhouse gas and is involved in the consum ption of the ozone (O 3 ) in the stratosphere. The NH 3 can lead to acidification of terrestrial and aquat ic environments, eutrophication of aquatic systems and production of N 2 O. The SLMG is suffering degradation in the water’s quality due to urbanization and agricultural activities in the region. This system is composed for four lagoon interconnected between themselves through channels: Maricá, Barra, Father and Guarapi na. For the analysis of N 2 O was used the technique of the static chamber and 4 models predic tion fluxes (MPF). In the case of NH 3 were made estimates of fluxes through MPF too. The results of this study show that the four lagoons in the SLMG have different behaviors with r espect to the fluxes of the two gases analyzed. Estimates of the rates of emission in th e system lagoon show that despite the present system lagoons that seem act as sink of N 2 O and NH 3 , in a general balance, it gives N to the atmosphere in one form or another. The estim ated emission rate ranged between 92,15 g N -1 day -1 and 104,77 g N -1 day -1 . Other information that brought this estimate was that the majority of emissions occur in the form of NH 3 with estimated emission of 84,79 g N -1 day -1 to 97,41 g N -1 day -1 .

Page generated in 0.1103 seconds