• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 67
  • 63
  • 8
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 182
  • 144
  • 137
  • 59
  • 51
  • 51
  • 45
  • 40
  • 38
  • 36
  • 34
  • 31
  • 30
  • 29
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Análise numérica do comportamento estrutural e da resistência de terças de aço restringidas pelas telhas / Numerical analysis of cold-formed purlin-sheeting systems focused on the structural behavior and strength

Luiz Carlos Marcos Vieira Junior 09 May 2007 (has links)
Terças e longarinas metálicas são geralmente projetadas no Brasil desconsiderando a interação com as telhas, ou seja, como barras isoladas, apesar da norma brasileira NBR 14762:2001 apresentar um procedimento de cálculo que leva em consideração tal interação (método do fator R). O comportamento estrutural do sistema terça-telha é complexo e a análise completa deve considerar a não-linearidade geométrica e física, bem como a influência do contato e da conexão terça-telha. Foram analisados modelos numéricos propostos na literatura e desenvolvido um modelo via método dos elementos finitos (MEF) que incorpora as não-linearidades e o contato terça-telha. O modelo foi calibrado com resultados experimentais e posteriormente foi realizada uma análise paramétrica, a qual permitiu gerar expressões que relacionam a força (vento de sucção) com os deslocamentos. Foi também analisada a viabilidade da aplicação do método da resistência direta (MRD) ao dimensionamento de terças restringidas pela telha, empregando o método das faixas finitas (MFF) para a análise de estabilidade elástica, em que a restrição promovida pela telha foi modelada por meio de vínculos elásticos na mesa conectada com a telha. Foram considerados dois casos de distribuição de tensões normais: (i) tensões oriundas somente da flexão e (ii) tensões oriundas da flexão e torção. Em ambos os casos o momento resistente apresentou diferenças relativamente elevadas em relação ao obtido pelo método do fator R, refletindo a necessidade de uma abordagem específica do método para o sistema terça-telha. / The structural behavior of purlin-sheeting system is complex and the complete analysis should consider the physical and geometrical nonlinearity, as well as the influence of the purlin-sheeting contact and connection. The brazilian code NBR 14762:2001 provides a design procedure to consider the interaction between a purlin or girt connected to the sheeting (factor R method). In Brazil purlins and girts are typically designed as isolated beams, without consideration for this purlin-sheeting combination. Numerical models proposed in the literature were analyzed and a finite element model (FEM) was developed considering nonlinearities and the contact between purlin and sheeting. The model was validated through experimental results and then implemented in a parametrical analysis. Expressions were generated using the parametrical results to relate the loading (wind uplift) to the displacements. The direct strength method (DSM) was analyzed to the designed of purlins restrained by sheeting. The finite strip method (FSM) was used for elastic buckling determination. The restraint applied to the sheeting was modeled using an elastic foundation on the flange connected to the sheeting. Two stress distributions were considered: (i) bending stresses and (ii) bending and warping stresses. In both cases the nominal flexural strength presented considerable differences compared to the factor R design method, reflecting the necessity of a specific study to evaluate the viability of the DSM approach for purlin design.
132

Análise teórica-experimental de perfis de aço formados a frio devido à instabilidade por distorção na flexão / Theoretical-experimental analysis of cold-formed steel for distortional buckling in flexural members

Julio Cesar Martins da Silva 24 September 2004 (has links)
Apresenta-se neste trabalho um estudo teórico-experimental sobre a instabilidade de perfis formados a frio submetidos à flexão. A instabilidade distorcional se faz comum na presença de tensões de compressão atuando sobre perfis enrijecidos e fabricados com aços de elevada resistência mecânica. A parte teórica abrange os métodos de cálculo analíticos e numéricos para a análise de instabilidade distorcional de perfis de seção aberta formados a frio. Na parte experimental inclui-se o estudo de perfis formados a frio com seções do tipo U enrijecidos submetidos aos ensaios à flexão. Nestes ensaios variou-se a altura de alma e espessura de chapa procurando-se abranger maior número de condições geométricas para análise da estabilidade distorcional. Inclui-se também a análise de instabilidade numérica dos perfis do programa experimental através do método de resistência direta via método das faixas finitas. Com base nos resultados experimentais, numéricos e na análise teórica do problema, verificou-se o procedimento adotado pela NBR14762/2001 e efetuou-se comparação entre curvas de resistência propostas para o dimensionamento de perfis formados a frio à flexão. Foi verificado que o fenômeno de instabilidade distorcional pode ser o estado limite último crítico para o dimensionamento dos perfis formados a frio. / This work present a study theoretical-experimental about the distortional buckling of cold-formed steel members under bending. The distortional buckling is common for members with edge-stiffened sections and manufactured with steel of high strength. The theorical part present the analitic and numerical methods for stability analysis by distortional buckling. The experimental part included the study of cold-formed with sections channel altering flange width and thickness by proof in flexural members. Included too the numerical analysis by Direct Strength Method in Finite Strip Method on members with the same configurations of experimental investigation. Based on the experimental measurements, numerical analysis and in the theorical analysis of work, verified the procedures adopted in brazilian code NBR14762/2001 and compared with others distortional curve proposed for to design of cold-formed members under bending. Verified that the distortional buckling may control the design being the critical mode for the ultimate limit state.
133

Viga mista de aço e concreto constituída por perfil formado a frio preenchido / Composite steel and concrete beam constituted by filled cold-formed steel section

Igor Avelar Chaves 20 January 2009 (has links)
As vigas mistas de aço e concreto têm sido amplamente empregadas em edifícios e pontes, havendo ampla investigação teórica e experimental a respeito da utilização de perfis laminados e soldados e conectores de cisalhamento compatíveis com esses perfis, como por exemplo, o conector tipo pino com cabeça (stud bolt) e perfil U laminado. No âmbito dos perfis formados a frio, a utilização do sistema misto ainda é incipiente, necessitando de investigações mais aprofundadas a respeito do comportamento estrutural e a adequação dos modelos de cálculo adotados para vigas mistas em perfis laminados e soldados. No Brasil, a ampla disponibilidade de aços planos tem impulsionado o emprego do sistema misto constituído por perfis formados a frio em edifícios de pequeno porte, porém, mediante concepções clássicas, o que não conduz a um aproveitamento mais racional do sistema. Neste trabalho foi investigado um sistema não-convencional de vigas mistas em perfil cartola leve preenchido com concreto, cuja conexão com a laje foi feita mediante duas soluções: conectores do tipo alça em barra chata soldados ao perfil e conectores do tipo alça em barra redonda soldados ao perfil. Foi feita avaliação do comportamento estrutural da conexão aço-concreto, via ensaios de cisalhamento direto (push-out tests), e ensaios em vigas mistas simplesmente apoiadas para avaliação da região de momento fletor positivo. Os conectores de cisalhamento apresentaram ductilidade e resistência compatíveis com as vigas mistas analisadas, e as respostas de rigidez e resistência à flexão para uma condição de interação completa comprovam que a hipótese de plastificação total da seção descreve com precisão o comportamento estrutural do sistema proposto. / The composite steel and concrete beams have been largely applied in buildings and bridges constructions, having also a large amount of theoretical and experimental investigations about the use of hot-rolled and welded shapes and shear connectors that are compatible with these members, as for an example, the stud bolt and channel connectors. In the cold-formed steel sections scope, the use of a composite steel and concrete solution is still premature, what makes necessary a higher degree of a structural behavior investigation and the adequacy of the theoretical solutions proposed, also for the composite steel and concrete hot-rolled and welded shapes. In Brazil, the high availability of steel sheets has pushed the employee of the composite system of cold-formed steel in small and mid-height buildings, however, because of classical conceptions, it doesn\'t lead too a more rational use of the system. It was investigated in this work a non-conventional lightweight composite system formed by hat-shaped beams filled with concrete, witch connection with the slab was done by means of two solutions: arc-shaped connectors in at bars welded too the section and arc-shaped connectors in round bars welded too the section. An analysis was conducted for evaluation of the structural behavior in the steel and concrete interface by push-out tests, and tests in simple two points supported beams for evaluation of the bending strength. The shear connectors showed ductility and resistance compatible with the analyzed composite beams and the stiffness and bending resistance responses for the given condition of full interaction showed that the full section plastification consideration describes with precision the structural behavior of the proposed system.
134

Análise teórica e experimental de barras em dupla cantoneira de aço formada a frio submetidas à compressão / Theoretical and experimental analysis of cold-formed steel double angle members under compression

Wanderson Fernando Maia 24 August 2012 (has links)
Barras compostas em dupla cantoneira são constituídas por duas seções idênticas dispostas paralelamente, afastadas entre si e ligadas uma a outra apenas em alguns pontos ao longo do comprimento, por meio de chapas separadoras. O sistema aqui apresentado é bastante utilizado, principalmente em estruturas treliçadas leves, no entanto, não existem estudos específicos sobre seu comportamento, como conseqüência as normas de cálculo não fornecem subsídios para o projeto desse componente estrutural. É relevante estudar o comportamento de barras em dupla cantoneira, já que neste caso, além dos modos de instabilidade associados à cantoneira isolada, poderão ocorrer modos de instabilidade associados à barra composta em função da presença das chapas separadoras, que tendem a modificar o comportamento do sistema. Apresenta-se no trabalho análises numérica e experimental sobre o comportamento de barras submetidas à compressão centrada e excêntrica. Nas análises variou-se o número de chapas separadoras buscando estudar a eficiência das mesmas na força normal resistente das barras. Os resultados mostraram que a introdução de chapas separadoras melhorou significativamente o comportamento das barras, principalmente para compressão excêntrica. Foram observados modos de instabilidade por flexo-torção, por flexão e combinação dos dois modos. Para comparação dos resultados, inicialmente foram adotadas duas hipóteses de cálculo com base no procedimento da ABNT NBR 14762:2010, considerando compressão centrada. No primeiro procedimento considerou-se cada cantoneira como uma barra isolada independente da presença das chapas separadoras, admitiu-se instabilidades local, por flexo-torção e por flexão; no segundo considerou-se barra composta admitindo-se apenas instabilidades local e por flexão em relação ao eixo principal de menor inércia do conjunto. Em geral, os resultados das análises numérica e experimental apresentaram valores intermediários aos obtidos pelas duas hipóteses adotadas inicialmente. Com os resultados obtidos nas análises numérica e experimental são recomendados procedimentos para o dimensionamento desse componente estrutural. / Double-angle members with batten plates consist of two identical angles set up in parallel, spaced apart, and connected to each other by batten plates at specified points along the length. The system presented herein is widely used, especially in light truss structures; however, there are no standard design procedures specific for the design of this structural component. Studying the behavior of double angle members is interesting, because in this case, besides the critical modes of the single angle, they also show critical modes, due to the presence of the batten plates that sometimes interfere with the behavior of the system. This work presents a numerical and experimental study of members under concentric and eccentric axial compression. The number of batten plates is changed to study the influence on the nominal axial strength. The use of batten plates significantly increases the strength of the system, especially for members under eccentric compression. The buckling modes observed were flexural-torsional, flexural and combination of the modes. Initially, two design hypotheses are compared to the results obtained: (i) non-composite action (no interaction between angles), with only local, flexural, and flexural-torsional buckling considered; (ii) composite action (full interaction between angles), and only considering local and minor-axis flexural buckling of the pair of angles. The two design hypotheses ignore load eccentricity. The hypotheses are based upon recommendations in ABNT NBR 14762:2010. In general, numerical and experimental results for angles connected by bolted batten plates fall in between the design curves defined by methods (i) and (ii). With the results obtained in numerical and experimental analysis, procedures are recommended for the design of this structural component.
135

Sobre o comportamento estrutural e o dimensionamento de cantoneiras de aço formadas a frio submetidas à compressão e conectadas por uma aba / On the structural behavior and the design of bolted cold-formed steel angles under compression

Maria Ávila Branquinho 24 February 2017 (has links)
A cantoneira de abas iguais é encontrada laminada ou formada a frio. Quando laminada, normalmente possui abas compactas, isto é, se submetida à compressão, não apresenta instabilidade local e, para a faixa usual de comprimentos, não apresenta também o modo global de flexo-torção como dominante. Quando formada a frio, estes modos predominam, uma vez que a relação largura-espessura torna-se elevada. A elevada esbeltez das abas, juntamente com as peculiaridades do seu comportamento mecânico, pode conduzir a significativas divergências entre a força axial resistente (experimental) quando comparada aos valores oriundos dos procedimentos de cálculo apresentados pelas normas. As divergências são ainda maiores quando se considera a cantoneira em sua situação mais usual: sob compressão excêntrica devido à ligação parafusada ou soldada em uma das abas. No presente trabalho foi analisado o comportamento mecânico das cantoneiras formadas a frio e conectadas pela aba por dois parafusos e desenvolvida uma formulação baseada no método do comprimento de flambagem equivalente, bem como identificados seus modos de instabilidade e a respectiva participação modal para diversas faixas de esbeltez. Para validar esta formulação, foi realizada uma análise de confiabilidade que resultou em índices de confiabilidade (β) de acordo com as exigências normativas. / The equal-leg angle is found hot-rolled or cold-formed. When hot-rolled, it usually has compact legs, that is, if subjected to compression it does not present local buckling and it does not present a global flexo-torsion buckling mode as dominant for the usual range of lengths. When cold-formed, these modes predominate, since the width-to-thickness ratio becomes high. The high slenderness of the legs, together with the peculiarities of its mechanical behavior, can lead to significant divergences between the axial strength (experimental) and the values from standard\'s procedures. The divergences are even greater when considering the angle in its most usual loading situation: under eccentric compression due to bolted or welded connection in one leg. In the present work the mechanical behavior of the cold-formed angles connected by the leg by two bolts was analyzed in order to propose a formulation based on the equivalent buckling length method, as well as, to define its buckling modes and the respective modal participation for different slenderness ranges. To validate this formulation, a reliability analysis was performed that resulted in reliability indexes (β) according to the design standards requirements.
136

Análise experimental de vigas de seção I compostas de perfis formados a frio com emendas soldadas, submetidas à flexão simples / Experimental analysis of beams of the "I" made up of cold formed steel with welded seams, subjected to simple bending

VIEIRA, Gregório Sandro 19 March 2010 (has links)
Made available in DSpace on 2014-07-29T15:03:30Z (GMT). No. of bitstreams: 1 Gregorio Sandro Vieira.pdf: 2051926 bytes, checksum: 3f1641739e31761ce674bd4e06e87c0d (MD5) Previous issue date: 2010-03-19 / This paper presents an experimental study done in bi-metal beams supported from 3000 mm in length, composed of thin-walled, resulting in a section of the "I". The beams were formed from the welding of the souls of two metal profiles of type U. The variables were the type of profile used, the quantity and positioning of the welded seams. The beams were divided into two groups where the first group used profiles of the "U" and the second group used simple profiles such as "U" stiff. Each group was composed of three beams so that a beam does not receive any amendment, another amendment received a girder high up in the middle of the span, and the third top beam was amended so that the position would result in an amendment pierced. The applied load was set so as to leave the central part of the beams, which served as a region of the present study, working in pure bending. Test results for beams without amendment were compared with the theoretical results and served as a parameter to compare the behavior of these beams, with beams that were amended. Also a comparison was made between the bearing capacity of the two groups of beams. The experiments showed that, by making the proper control of welding there is no problem in making welded seams in the rafters. We also observed that the simple addition of stiffening beams tables promotes a significant increase in the bearing capacity. There was no correlation between failure modes provided theoretically and observed experimentally, thus, further studies are needed to properly analyze the theoretical results with experimental results. / Este trabalho apresenta um estudo experimental feito em vigas metálicas bi-apoiadas de 3000 mm de comprimento, compostas por perfis formados a frio, resultando em uma seção do tipo I . As vigas foram formadas a partir da soldagem das almas de dois perfis metálicos do tipo U. As variáveis estudadas foram o tipo de perfil utilizado, a quantidade e o posicionamento das emendas soldadas. As vigas foram dividas em dois grupos onde, o primeiro grupo utilizou perfis do tipo U simples e o segundo grupo utilizou perfis do tipo U enrijecido. Cada grupo foi composto por três vigas de forma que uma viga não recebeu nenhum tipo de emenda, outra viga recebeu uma emenda de topo no meio do vão, e a terceira viga recebeu emendas de topo de forma que o posicionamento resultasse em uma emenda trespassada. O carregamento aplicado foi disposto de forma a deixar a parte central das vigas, que serviu como região de estudo deste trabalho, trabalhando em flexão pura. Os resultados dos ensaios para as vigas sem emenda foram comparados com os resultados teóricos e serviram de parâmetro para a comparação do comportamento destas vigas, com o das vigas que receberam emendas. Também foi feita uma comparação entre a capacidade portante dos dois grupos de vigas. Os experimentos constataram que, fazendo-se o controle adequado da soldagem não há problemas em se fazer emendas soldadas nas vigas. Também foi observado que o simples acréscimo de enrijecimento nas mesas das vigas promove um acréscimo significativo da capacidade portante. Não houve concordância entre os modos de ruptura previstos teoricamente e os observados experimentalmente, assim, são necessários mais estudos para se analisar adequadamente os resultados teóricos com os resultados experimentais.
137

Análise experimental de vigas constituídas de perfis formados a frio com emendas soldadas submetidas à flexão simples / Experimental analysis of beams made of cold formed steel with welded seams subjected to bending

ALMEIDA, Ariovaldo Fernandes de 23 September 2009 (has links)
Made available in DSpace on 2014-07-29T15:03:30Z (GMT). No. of bitstreams: 1 Dissertacao ariovaldo ecivil 2009.pdf: 972968 bytes, checksum: 9d1288c7a6be7d0bce6e1136f5b34c12 (MD5) Previous issue date: 2009-09-23 / The cold-formed steel sheets have been sufficiently used when it is thought of manufacturing a metallic structure with reduced weight. Its use until some time ago in construction was limited to the secondary structures, but, with considerable growth in research involving this type of material together with development of technical standards, made its use a good solution for certain types of light structures. The present work presents considerations on cold-formed steel sheets, the patened steel, processes of welding and the result of experimental tests with beams with composed section of two profiles U constituted with cold-formed steel sheets, manufactured with two types of patened steel produced in Brazil. In some of these beams, welded sections with coated electrode had been used and were made the comparison with the reference beam, where it was possible to study the influence of the process of welding in the ultimate resistance and the ductility of the beam. / Os perfis metálicos formados a frio tem sido bastante usados quando se pensa em fabricar uma estrutura metálica com peso próprio reduzido. O seu uso até a algum tempo atrás na construção civil estava limitado apenas a estruturas secundárias, mas, com o crescimento considerável de pesquisas envolvendo este tipo de material associadas ao desenvolvimento de normas técnicas, fez com que o seu uso apresentasse uma boa solução para determinados tipos de estruturas leves. O presente trabalho apresenta considerações sobre perfis formados a frio, aços patináveis, processos de soldagem e o resultado de ensaios experimentais de vigas bi-apoiadas constituídas de perfis formados a frio compostas pela junção de dois perfis U enrijecidos, fabricadas com dois tipos de aço patináveis produzidos no Brasil, comparando-se os resultados. Em algumas destas vigas foram feitas emendas soldadas com eletrodo revestido e foi feita a comparação com vigas de referência, sem emenda soldada, possibilitando o estudo da influência do processo de soldagem na resistência à flexão e na ductilidade das vigas.
138

Análise de confiabilidade em ligações parafusadas em chapas finas e perfis de aço formados a frio / Reliability analysis in bolted connections in thin sheets and cold-formed steel members

Emerson Alexandro Bolandim 11 May 2011 (has links)
Este trabalho apresenta uma investigação de modelos analíticos de previsão da força de tração resistente para ligações parafusadas em chapas finas e perfis de aço formados a frio, de acordo com quatro especificações de projeto (ABNT NBR 14762:2010, ANSI AISI S100:2007-S, AS/NZS 4600:2005 e EUROCODE 3 Parte1.3:2010). O estudo envolveu 404 resultados experimentais de ligações parafusadas, sendo: 232 ligações em chapas finas, 104 ligações em cantoneiras e 68 ligações em perfis U, em que diversas configurações geométricas foram analisadas. No total 1616 análises de força resistente foram realizadas de modo que estatísticas da variável aleatória erro de modelo pudessem ser construídas. Dessa forma, a análise de erro de modelo consistiu da plotagem das probabilidades do erro de modelo, para que em seguida testes de aderência pudessem ser então aplicados de modo satisfatório, validando funções teóricas de distribuição de probabilidades para a representação da informação estatística dessa variável aleatória. Uma análise de regressão foi utilizada nas ligações parafusadas para descrever a variação do erro de modelo com a espessura da chapa e para descrever a incerteza de modelo. As análises realizadas mostraram que os modelos brasileiros e americanos conseguem prever, em média, a ruptura da seção líquida de maneira mais eficiente do que as outras especificações, pois utilizam coeficientes de redução da área líquida, e também apontam que todos os modelos apresentam uma grande variabilidade dos resultados em torno da média, o que faz com que a confiabilidade dos modelos seja prejudicada. A análise de confiabilidade, utilizada para avaliar o nível de segurança das especificações de projeto, incluiu o erro de modelo e outros parâmetros aleatórios como a resistência à ruptura do aço, ação permanente (D) e variável (L), totalizando 7092 análises em ligações parafusadas, revelando que a contribuição da variável aleatória erro de modelo na segurança dessas ligações é considerável, especialmente para razões de carregamento (Ln/Dn) entre 0,50 e 2,50. Cabe ainda observar que as especificações de projeto foram avaliadas de acordo com critérios de confiabilidade uniforme e suficiente, demonstrando que a uniformidade é alcançada de maneira mais fácil para as quatro especificações, para razões de carregamento (Ln/Dn) maiores que 2,0, e que a suficiência de segurança, na maioria das análises realizadas, não foi alcançada, principalmente para o modo de ruína de esmagamento da parede do furo, em que os índices de confiabilidade para as ligações situaram-se em torno de 2,0 a 2,5, abaixo do valor alvo de 3,5 estabelecido pelo AISI e 3,8 estabelecido pelo EUROCODE. Além disso, ao se tratar da ruptura da seção líquida, os modelos brasileiro, americano e australiano também não atingiram níveis desejáveis de segurança, contudo, fornecem probabilidades de falha bem abaixo das obtidas para o modo de ruína de esmagamento. Por fim, análises de sensibilidade revelaram que os parâmetros x/L e d/g, presentes nos modelos analíticos de previsão da ruptura da seção líquida, para a especificação brasileira e americana, não interferem na segurança estrutural das ligações. / This work presents an investigation of analytical models for predicting the tensile strength to bolted connections in thin sheets and cold-formed steel members, according to four design specifications (ABNT NBR 14762:2010, ANSI AISI S100:2007-S, AS/NZS 4600:2005 and Eurocode 3 Parte1.3:2010). The study involved 404 experimental results of bolted connections, as follows: 232 connections in thin sheets, 104 connections in angles and 68 connections in channels, in which various geometric configurations were analyzed. A total of 1616 strength analysis were performed so that statistics of the random variable model error could be constructed. Thus, the model error analysis consists of plotting the probability of error model, then for the adherence tests could then be applied satisfactorily validating theoretical functions of probability distribution for the statistical representation of random variable. A regression was used in bolted connections to describe the variation of the model error with the thickness of the sheet and to describe the model uncertainty. The analysis showed that the models can predict Brazilians and Americans, on average, net section fracture more efficiently than the other specifications, for use of coefficient of reduction of net area, and also note that all models showed a great variability of results around the mean, which makes the reliability of the models is affected. The reliability analysis used to assess the safety level of design specifications, included the model error and other random parameters such as tensile strength of steel, dead (D) and live (L) loads, totaling 7092 analysis on bolted connections, revealing that the contribution the random variable model error in the security of these connections is considerable, especially for load ratios (Ln/Dn) between 0.50 and 2.50. It should also be noted that the design specifications were evaluated according to sufficient and uniform reliability criteria showing that uniformity is achieved more easily for the four specifications, for load ratios (Ln/Dn) higher than 2.0, and that the sufficiency of security, most of the analysis, is not achieved, especially for the failure modes of bearing of the hole, in which the reliability index for the connections are located around 2.0 to 2.5, below the target value of 3.5 indicated by AISI and 3.8 indicated by EUROCODE. Furthermore, when dealing with the net section fracture, the models Brazilian, American and Australian also did not reach desirable levels of security, however, provided failure probabilities well below those obtained for the failure modes of bearing. Finally, sensitivity analysis revealed that the parameters x/L and d/g, present in the analytical models for predicting the net section fracture, the specification for Brazilian and U.S., do not affect the structural safety of the connections.
139

Tecnologia construtiva de fachada em chapas delgadas estruturadas em light steel framing. / Light stell external wall system.

Silvia Scalzo Cardoso 20 January 2016 (has links)
Aumento da produtividade, melhorias na qualidade dos produtos, redução de custos e de impactos ambientais são essenciais para a capacidade competitiva das empresas. A execução da fachada faz parte do caminho crítico da obra, por ser um subsistema que associa as funções de fechamento, acabamento, iluminação e ventilação e ainda por incorporar sistemas prediais; apresenta, por isso também, um alto custo direto em relação aos outros subsistemas do edifício. A tecnologia construtiva de fachadas em chapas delgadas com estrutura em Light Steel Framing (LSF) é uma alternativa viável para aumentar a produtividade e reduzir os prazos de obra, com qualidade e desempenho, e pode trazer benefícios em relação a atividades intensas em mão de obra como é o caso da alvenaria de vedação e de seus revestimentos. O presente trabalho tem por objetivo sistematizar e analisar o conhecimento relativo a essa tecnologia construtiva de fachada. O método adotado compreende revisão bibliográfica. Como contribuição, o trabalho reúne um conjunto organizado de informações sobre os principais sistemas disponíveis no mercado contemplando: a caracterização do sistema de fachada, de suas camadas e dos perfis leves de aço e a sistematização das principais avaliações técnicas de sistemas existentes em outros países, reunindo normas técnicas de produtos e de execução. Acredita-se que a reunião e organização das informações, antes dispersas em diversas referências, têm potencial para subsidiar o meio técnico para tomada de decisão quanto ao uso adequado da nova tecnologia. / Increase productivity, improve product quality and reducing costs and environmental impact are essential for a competitive business. One of the critical paths of construction projects is the execution of the façade, a subsystem that associates multiple functions as sealing, finishing, lighting and ventilation feature and may incorporate other building systems. As another characteristic of these properties, a façade possess an important direct cost in relation to other subsystems. The building technology of light steel external wall system is a viable alternative, as it holds a potential to increase productivity, reduce construction deadline and bring benefits in regards to the labor heavy nature of masonry and mortar cladding. This research aims to organize the knowledge on the building technology of light steel external wall facade. The research method comprises a technical literature review. As a result, this study combines an organized ensemble of information about characterization of the light steel external wall system, its layers and steel profile. The work also performs an analysis of technical evaluations of existing systems in other countries, gathering technical standards of products and assembling techniques. The information here presented may serve as reference to the technical community by compiling and organizing information available in various and dispersed references.
140

Ligações parafusadas em chapas finas e perfis de aço formados a frio / Bolted connections in thin sheet and cold-formed steel members

Carlos Henrique Maiola 29 June 2004 (has links)
Devido à crescente demanda por perfis formados a frio destinados à fabricação de estruturas de aço no Brasil, aliada a desatualização da norma brasileira NB-143:1967, fez-se necessário a publicação de uma nova norma brasileira de \'Dimensionamento de Estruturas de Aço Constituídas por Perfis Formados a Frio\' a NBR14762:2001. Essa apresenta, para o dimensionamento das ligações, expressões adaptadas da norma norte-americana AISI:1996. As adaptações foram inseridas com o intuito de simplificar o cálculo e foram determinadas apenas por ajustes teóricos, faltando, portanto uma investigação mais criteriosa. Deste modo tornou-se prioritário o estudo das ligações em chapas e perfis com pequena espessura, para avaliação destas expressões propostas. Neste âmbito analisou-se neste trabalho o comportamento estrutural de ligações parafusadas em chapas e perfis formados a frio de pequena espessura, mediante análise teórica e experimental de corpos-de-prova, os quais foram definidos de maneira a se obter os diversos modos de falha, em especial a ruptura da seção líquida. Com os resultados experimentais pôde-se sugerir modificações nas expressões do coeficiente redutor da área líquida Ct, aplicado na avaliação da resistência ao estado limite de ruptura da seção líquida efetiva. Com os resultados desta pesquisa, espera-se colaborar com futuras edições da norma brasileira, fornecendo subsídios em suas futuras revisões. / The growing demand for cold-formed steel members of steel structures in Brazil, allied to the obsolescence of the brazilian NB-143:1967 standard, led to the need for a new brazilian code for the \'Design of Cold-formed Steel Structural Members\', the NBR14762:2001 standard. This new standard contains expressions adapted from the american AISI:1996 code for the design of connections. The adaptations were included with the purpose of simplifying the calculation and were determined merely for theoretical adjustments; hence, they lack a more careful investigation. It has thus become a matter of priority to study the connections in thin sheets and cold-formed members to evaluate the proposed expressions. The work reported on here therefore analyzed the structural behavior of bolted connections in thin sheets and cold-formed members based on theoretical and experimental analyses of test specimens, which were defined in order to obtain the various failure modes, particularly on sheet tearing in the net section. Based on the experimental results, suggestions are made for modifications in the expressions of the reduction coefficient of the net area Ct, applied in evaluations of the tensile strength of the effective net section. It is expected that the results of this research will contribute to future editions of the new brazilian code, supplying inputs for use in future revisions.

Page generated in 0.0381 seconds