• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 193
  • 4
  • 2
  • Tagged with
  • 202
  • 80
  • 64
  • 55
  • 50
  • 45
  • 42
  • 35
  • 33
  • 33
  • 33
  • 32
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Análise técnica e ergonômica da produção de carvão vegetal de uma bateria de fornos de superfície do tipo rabo-quente / Technical and ergonomic analysis of charcoal production using “rabo quente” masonry kilns

Faria, Manoel Marques de 19 December 2003 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-12-15T10:47:19Z No. of bitstreams: 1 texto completo.pdf: 1563492 bytes, checksum: 90b3a88f8f22164c42ea6092e91deddb (MD5) / Made available in DSpace on 2016-12-15T10:47:19Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1563492 bytes, checksum: 90b3a88f8f22164c42ea6092e91deddb (MD5) Previous issue date: 2003-12-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo geral deste trabalho foi analisar os fatores ergonômicos no processo de produção de carvão vegetal em uma bateria de fornos rabo- quente, almejando uma melhoria no bem-estar, na saúde, na segurança, no conforto e na produtividade do operador de fornos de carbonização. Os objetivos específicos deste trabalho foram: 1) fazer um levantamento das condições de trabalho do operador de fornos de carbonização; 2) avaliar as características pessoais, sociais, econômicas e profissionais do operador; 3) avaliar os clima do local de t abalho (temperatura); 4) avaliar a capacidade r aeróbica do trabalhador; 5) avaliar a carga de trabalho do operador através do batimento cardíaco durante a jornada; 6) realizar o estudo do tempo consumido nas operações de carbonização; 7) fazer uma avaliação biomecânica das operações de carbonização. A metodologia empregada foi proposta por APUD (1987), COUTO (1996) e SANTANNA (1998). Pela análise das características geográfica-edafoclimáticas, do sistema de trabalho e da rotina diária, pôde-se perceber que as condições são adequadas para que o operador de fornos de carbonização desenvolva bem sua atividade laboral. Observou também que o operador de fornos de carbonização é um indivíduo jovem, mestiço, casado, com poucos filhos e poucos dependentes financeiros, baixo nível de escolaridade, estatura média de 171,40 cm e média de peso corporal de 68,40 kg. Dos entrevistados, 20% disseram ser analfabetos. Constatou-se que o operador é de origem predominantemente rural e religião católica. Além disso, registrou que os valores do índice de bulbo úmido e termômetro de globo (IBUTG) encontrados nos locais onde se desenvolveram as operações na atividade de carbonização estavam dentro dos limites estipulados pela Legislação Brasileira; não havendo sobrecarga térmica. Pelos resultados encontrados no teste do banco de Astrand, foi possível notar que o operador de fornos de carbonização possui uma boa capacidade aeróbica. Concluiu que a atividade de carbonização é considerada moderadamente pesada. Classificou também a carga de trabalho físico em cada operação em que a carga/descarga foi classifica como pesada e moderadamente pesada; barrelamento e expedição foram classificadas como moderadamente pesados; vedação, como leve. Havendo necessidade de pausas ao longo da jornada n operação de a carga/descarga. No estudo do tempo consumido em cada operação certificou- se que a operação de descarga consumiu menor tempo equivalente à 41% do total da jornada; as operações de carga e limpeza consumiram 60%; a operação de vedação é a que consumiu maior tempo correspondendo a 61,6% na jornada diária que é de 6 horas. Por meio da análise biomecânica, foi demonstrado que o limite de carga recomendado em todas as operações não seria suportado em todas as articulações pela maioria dos indivíduos. Na operação de carga, na fase de levantamento e deslocamento da tora, poderia haver risco de compressão do disco da coluna vertebral lombar 5 e sacro 1 (L5- S1), podendo causar lesão se o esforço fosse muito freqüente. / The objective of this work is to analyze ergonomic factors in charcoal production using masonry kilns called “rabo quente”, in order to improve health, safety, comfort and productivity of kiln operators. The specific objectives of this work are: 1) to evaluate work conditions for the kiln operator; 2) to evaluate personal, social, economic and professional characteristics of the operator; 3) to evaluate the climate (temperature) at the workplace; 4) to evaluate the operator’s aerobic capacity; 5) to estimate the w orking load for the operator from measuring heartbeating during the day; 6) to estimate time spent in the carbonization operations; 7) to do a biomechanical evaluation of carbonization tasks. The results of the analysis of geographic and edafoclimatic characteristics, work system and daily work routine showed that the work conditions are appropriate. It was observed that the kiln operator is a young, mestizo and married individual, with few children and few dependants, low education, average height of 171,40 cm and average weight of 68,40 kg. Twenty per cent of the interviewees declared themselves as illiterate, catholic and from countryside. The global thermometer and humid bulb index values found at the work place were within the limits stipulated by the regulating standard, with no thermal overload occurring. By the results found by using Astrand test, it was concluded that the kiln operator has a good aerobic capacity. The carbonization activity is considered moderately heavy, and the working load is classified as heavy and moderately heavy for load and unload operations, respectively, for what pauses are needed during the day. The barrelamento and shipping operations are classified as moderately heavy; the operation of sealing, as light. By estimating time spent in the carbonization activity, it can be observed that the unloading operation took 41% of the day; loading and cleaning operations took 60% of the work routine, and the sealing operation took 61,6% of the 6-hour daily routine. The results of the biomechanical analysis showed that the limit working load recommended in all operations would not be supported in all articulations for most individuals. In the loading operation, at the steps of lifting up and moving the log, a compression of the lumbar 5 and sacrum 1 spinal disk (L5-S1) is possible, causing an injury if the exposure is frequent. / Não foi encontrado o cpf do autor.
22

Investigação da amostragem direta para determinação de elementos traço em carne in natura e em petróleo usando espectrometria de absorção atômica com forno de grafite

Damin, Isabel Cristina Ferreira January 2009 (has links)
Neste trabalho foram desenvolvidos diferentes métodos analíticos para serem aplicados rotineiramente na determinação direta de elementos de interesse em amostras de petróleo e de carne in natura, usando a espectrometria de absorção atômica com forno de grafite (GF AAS). Os métodos foram baseados na análise das amostras mediante introdução direta no forno de grafite (SS-GF AAS), sem nenhum tratamento prévio. Inicialmente foi investigada a possibilidade da determinação direta de níquel, vanádio e chumbo em amostras de petróleo. A fim de contornar as perdas de compostos voláteis, foi investigado o uso de diferentes modificadores químicos (convencional e permanente) e os resultados obtidos foram comparados com HR-CS AAS (espectrômetro de absorção atômica de alta resolução com fonte contínua). As análises de amostras de petróleo em emulsões usando um Forno com filtro (THFA) foram também investigadas para determinação de chumbo. Na segunda parte do trabalho foi investigada a determinação direta de chumbo e cádmio em amostras de carne in natura (amostrada diretamente ou sob a forma de suspensão). Todos os resultados foram satisfatórios para aplicação de rotina, e a comparação entre os resultados obtidos para os métodos propostos e os obtidos com os métodos tradicionais não apresentaram diferenças estatísticas significativas. / The goal of this work was to investigate different methods using graphite furnace atomic absorption spectrometry (GF AAS) for direct determination of elements of interest in petroleum and fresh meat to be applied as a rapid routine procedure. The methods were based on analysis of samples weighed directly onto solid sampling platforms and introduced into a transversely heated solid sampling graphite tube, without previous treatment. In the first moment it was investigated of the possibility of direct determination of nickel, vanadium and lead in petroleum. In order to avoid the problem of losses of volatile compounds different chemical modifiers (conventional and permanent) have been investigated and the results obtained were compared with those obtained by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS AAS) by emulsion technique. The analysis of petroleum samples in emulsions using a filter furnace (THFA) was also investigated for lead determination. In the second part of this work it was investigated a method for direct determination of lead and cadmium in fresh bovine meat (solid or slurry sampling). The overall result was very satisfactory for routine application, and the comparison with the conventional methods shows no significant statistical differences between the results.
23

Desenvolvimento de métodos analíticos para a determinação de mercúrio e selênio utilizando técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite

Potes, Mariana da Luz January 2018 (has links)
A geração química de vapor (CVG) e a geração fotoquímica de vapor (PVG) são técnicas analíticas empregadas na conversão do analito, presente na fase condensada, em uma espécie volátil, previamente a sua introdução no sistema de detecção. Neste trabalho foram desenvolvidos procedimentos analíticos para a determinação de Hg e Se em amostras biológicas por técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite (GF AAS). A determinação exata e precisa de Hg em amostras de peixe foi possível após a solubilização em hidróxido de tetrametilamônio e adição de n-propanol, como composto orgânico de baixo peso molecular, e detecção por PVG-GF AAS. O método analítico desenvolvido com o emprego da técnica de PVG para a determinação de Se em água de coco por GF AAS resultou em limites de detecção e quantificação de 0,65 μg L-1 e 2,2 μg L-1, respectivamente, os quais foram semelhantes aos obtidos por CVG. Os métodos desenvolvidos para a determinação de Hg e Se por PVG-GF AAS em amostras biológicas são sensíveis, livres de interferência espectral, de baixo custo e representam uma alternativa viável a CVG. / Chemical vapor generation (CVG) and photochemical vapor generation (PVG) are analytical techniques used to convert the analyte into a volatile species in liquid phase, before the introduction into the detection system. In this study, analytical procedures for the determination of Hg and Se in biological samples by vapor generation techniques coupled to graphite furnace atomic absorption spectrometry (GF AAS) were developed. Accurate Hg determination in fish samples was possible after a solubilization in tetramethylammonium hydroxide and adding n-propanol, as low molecular organic compound, using PVG-GF AAS. The developed method for Se determination in coconut water with PVG-GF AAS have resulted in limits of detection and quantification of 0,65 μg L-1 and 2,2 μg L-1, respectively and that were similar with those obtained with CVG. The developed methods for Hg and Se determination in biological samples using PVG-GF AAS are sensitive, free of spectral interference, low-cost, and are a feasible alternative for CVG.
24

Estratégias de análise direta de amostras para determinação de elementos traço em biomassa e seus produtos de pirólise por espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite

Duarte, Álvaro Tavares January 2014 (has links)
No presente trabalho foi investigada a viabilidade da aplicação da técnica de análise direta (com mínimo preparo de amostra) por espectrometria de absorção atômica de alta resolução com fonte continua e fomo de grafite (DS-HR-CS GF AAS). Métodos foram desenvolvidos para a determinação de chumbo, cádmio e cromo em amostras de biomassa, bio-óleo, água de pirólise e cinzas de biomassa (obtidos através de processo de pirólise ). As determinações foram realizadas sem adição de modificador quimico e utilizando calibração com soluções padrão aquosas. A determinação de cádmio e cromo foi realizada de maneira sequencial, ou seja, feita somente uma pesagem de amostra para determinação dos dois elementos, que possibilita trabalhar com uma menor quantidade de amostra e aumenta a velocidade analítica do método. Os métodos desenvolvidos se mostraram sensíveis, exatos, precisos e aplicáveis à rotina, com exceção do método desenvolvido para determinação sequencial de cádmio e cromo em amostras de bio-óleo, que apresentou limitações para determinação de cádmio. Após a determinação desses metais nas amostras analisadas, foi realizado um balanço de massas e estimado que a maior parte de chumbo e cromo presente na biomassa é eliminada para o ambiente durante o processo de pirólise, ficando uma parte significante retida nas cinzas. / In this work was investigated the feasibility of applying the technique of direct analysis (with a minimum sample preparation) by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS DS-GF AAS). Methods have been developed for the determination o f lead, cadmium and chromium in biomass, bio-oil, the aqueous phase o f the pyrolysis, and biomass ashes ( obtained by the pyrolysis process ). Ali measurements were performed without chemical modifier and using aqueous standard solutions for calibration. The determination of cadmium and chromium was performed in a sequential mode, determining both elements from the same sample aliquot, which allows work:ing with a small quantity of sample and increases the speed of the analytical method. The developed methods were sensitive, accurate and applicable to routine, with the exception of the method for sequential determination of cadmium and chromium in bio-oil, which presented lirnitations for the determination of cadmium. After determination ofthese metais in the samples, a mass balance was performed and estimated that most of the lead and chromium present in the biomass were emitted to the environment during the pyrolysis process, with a significant portion retained in the ashes.
25

Investigação da amostragem direta para determinação de elementos traço em carne in natura e em petróleo usando espectrometria de absorção atômica com forno de grafite

Damin, Isabel Cristina Ferreira January 2009 (has links)
Neste trabalho foram desenvolvidos diferentes métodos analíticos para serem aplicados rotineiramente na determinação direta de elementos de interesse em amostras de petróleo e de carne in natura, usando a espectrometria de absorção atômica com forno de grafite (GF AAS). Os métodos foram baseados na análise das amostras mediante introdução direta no forno de grafite (SS-GF AAS), sem nenhum tratamento prévio. Inicialmente foi investigada a possibilidade da determinação direta de níquel, vanádio e chumbo em amostras de petróleo. A fim de contornar as perdas de compostos voláteis, foi investigado o uso de diferentes modificadores químicos (convencional e permanente) e os resultados obtidos foram comparados com HR-CS AAS (espectrômetro de absorção atômica de alta resolução com fonte contínua). As análises de amostras de petróleo em emulsões usando um Forno com filtro (THFA) foram também investigadas para determinação de chumbo. Na segunda parte do trabalho foi investigada a determinação direta de chumbo e cádmio em amostras de carne in natura (amostrada diretamente ou sob a forma de suspensão). Todos os resultados foram satisfatórios para aplicação de rotina, e a comparação entre os resultados obtidos para os métodos propostos e os obtidos com os métodos tradicionais não apresentaram diferenças estatísticas significativas. / The goal of this work was to investigate different methods using graphite furnace atomic absorption spectrometry (GF AAS) for direct determination of elements of interest in petroleum and fresh meat to be applied as a rapid routine procedure. The methods were based on analysis of samples weighed directly onto solid sampling platforms and introduced into a transversely heated solid sampling graphite tube, without previous treatment. In the first moment it was investigated of the possibility of direct determination of nickel, vanadium and lead in petroleum. In order to avoid the problem of losses of volatile compounds different chemical modifiers (conventional and permanent) have been investigated and the results obtained were compared with those obtained by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS AAS) by emulsion technique. The analysis of petroleum samples in emulsions using a filter furnace (THFA) was also investigated for lead determination. In the second part of this work it was investigated a method for direct determination of lead and cadmium in fresh bovine meat (solid or slurry sampling). The overall result was very satisfactory for routine application, and the comparison with the conventional methods shows no significant statistical differences between the results.
26

Desenvolvimento de métodos analíticos para determinação de elementos traço em materiais poliméricos utilizando amostragem sólida por espectrometria de absorção atômica em forno de grafite

Duarte, Álvaro Tavares January 2010 (has links)
A União Europeia ao adotar as diretivas: 2002/96/EC — WEEE e a 2002/95/EC — RoHS de modo a minimizar os resíduos equipamentos eletroeletrônicos (WEEE — do inglês: Waste Eletrical Electronic Equipment) e restringir as substancias nocivas (RoHS — do inglês: Restriction of Hazardous Substances) vem causando um grande impacto na rotina de controle de substancias perigosas, incluindo metais taco tóxicos, como chumbo, cadmio e cromo, em todos os materiais que são utilizados nesses equipamentos. Os componentes plásticos são os principais constituintes dos equipamentos eletrônicos e uma potencial fonte de metais taco tóxicos que são adicionados como estabilizantes, corantes e catalisadores. Como esses materiais plásticos são desenvolvidos de modo a serem resistentes a ataques químicos, eles são normalmente difíceis de serem dissolvidos. Sob esta motivação, neste trabalho foram desenvolvidos e otimizados métodos para a determinação de cadmio, chumbo e cromo utilizando a técnica de amostragem direta de sólidos por espectrometria de absorção atômica com forno de grafite. Em todos os procedimentos o foco principal foi a redução de tratamento das amostras, bem como o emprego de soluções padrão aquosas a fim de tornar os métodos mais simples e facilmente aplicáveis a rotina. O use de modificador químico, mistura de paládio e magnésia foi mandatório para estabilizar cadmio e chumbo. As determinações de cromo foram realizadas sem a adição de modificador químico. Calibração versus padrões aquosos Ode ser utilizada para a determinação dos três analitos. Nas determinações de chumbo e de cromo de modo a ter uma maior faixa linear de concentração usou-se o artificio de trabalhar com ou sem fluxo de gás na etapa de atomização. No caso da determinação de cadmio linhas analíticas (228,8 nm e 326,1 nm) com diferentes sensibilidades foram empregadas para ampliar a faixa linear do método. Os limites de detecção foram: 0,7 lig kg-1, 22 prg kg1 e 13 jig kg-1 para cadmio, chumbo e cromo, respectivamente. Materiais de referencia certificados foram utilizados para a validação dos métodos, não havendo diferença significativa entre os valores obtidos e os certificados. Oito amostras de resíduos de equipamentos eletroeletrônicos foram analisadas, estando todas em conformidade com as diretivas WEEE e RoHS. / By adopting the directives 2002/96/EC — WEEE (Waste Eletrical and Electronic Equipment) and 2002/95/EC — RoHS (Restriction of Hazardous Substances) the European Union will cause a great impact on the routine control of hazardous substances, including toxic trace metals, such as lead, cadmium and chromium, in all the materials that are used in this kind of equipment. Plastic components are among the main constituents of electronic equipment and a potential source of toxic trace metals, which are added as stabilizers, catalysts and/or colorant. As these plastic materials are designed to be resistant against chemical attack, they are usually very difficult to bring into solution. Because of that, methods have been developed and optimized in this work for the determination of cadmium, lead and chromium using direct solid sampling graphite furnace atomic absorption spectrometry. The primary aspects in all all method development have been reduction of sample treatment and the use of aqueous Standards for calibration in order to make methods simple and easily applicable in routine. The use of a mixture of palladium and magnesium as a chemical modifier was found to be mandatory for the determination of cadmium and lead, whereas no modifier was necessary for the determination of chromium. Calibration against aqueous standards could be used for all three analytes. In order to increase the linear working range for the determination of chromium and lead, the determination has been carried out with the internal gas flow turned off and on, respectively, during atomization. In the case of cadmium, the analytical lines at 228.8 nm and 326.1 nm, respectively, with significantly different sensitivities were used for that purpose. The detection limits were 0.7 p.g kg', 22 pig kg-1 and 13 !,ig kg-1 for cadmium, lead and chromium, respectively. Certified reference materials were used for validation of the methods, and there was no significant difference between the found and the certified values. Eight samples of residues of electronic equipment have been analyzed, and all of them were within the limits of the directives of WEEE and RoHS.
27

Avaliação da viabilidade técnica da utilização de misturas do carvão faxinal com importados para injeção em altos-fornos

Gomes, Maria de Lourdes Ilha January 2004 (has links)
Neste trabalho, fez-se uma avaliação da reatividade do carvão gaúcho da mina de Faxinal com 17% de cinzas, de dois carvões importados, bem como das misturas destes carvões em diferentes proporções mássicas. Além disso, quantificou-se outros parâmetros importantes para o processo de injeção do carvão pulverizado (PCI) na fabricação do gusa via alto-forno, como o teor de cinzas, teor de matéria volátil e composição química das cinzas. A reatividade foi avaliada em termos da reação de gaseificação com CO2, em termobalança, sob condições isotérmicas e pressão atmosférica. Os experimentos foram realizados na temperatura de 1050ºC com CO2 puro, utilizando amostras com granulometria menor que 75 mm. Avaliou-se o efeito da geometria do cadinho e vazão de gás sobre a taxa de reação para garantir uma situação de controle cinético na reação de gaseificação. Os resultados experimentais revelaram que o carvão de Faxinal possui uma reatividade muito maior frente ao CO2 do que os carvões importados. O tempo para que se complete a reação, parâmetro importantíssimo no processo do alto-forno que utiliza PCI, é muitíssimo menor para o carvão de Faxinal do que para os carvões importados. As misturas de carvões revelaram um comportamento aditivo quanto à reatividade e aos demais parâmetros estudados. Observou-se que quanto maior o teor de carvão gaúcho presente na mistura, maior sua reatividade e menor é o tempo gasto para atingir a taxa máxima de reação. Em função dos resultados de reatividade, teor de cinzas e composição química das cinzas obtidos, permitiu-se indicar uma mistura com até 50% de carvão de Faxinal para ser testada na injeção de carvão pulverizado.
28

Desenvolvimento de métodos analíticos para a determinação de mercúrio e selênio utilizando técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite

Potes, Mariana da Luz January 2018 (has links)
A geração química de vapor (CVG) e a geração fotoquímica de vapor (PVG) são técnicas analíticas empregadas na conversão do analito, presente na fase condensada, em uma espécie volátil, previamente a sua introdução no sistema de detecção. Neste trabalho foram desenvolvidos procedimentos analíticos para a determinação de Hg e Se em amostras biológicas por técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite (GF AAS). A determinação exata e precisa de Hg em amostras de peixe foi possível após a solubilização em hidróxido de tetrametilamônio e adição de n-propanol, como composto orgânico de baixo peso molecular, e detecção por PVG-GF AAS. O método analítico desenvolvido com o emprego da técnica de PVG para a determinação de Se em água de coco por GF AAS resultou em limites de detecção e quantificação de 0,65 μg L-1 e 2,2 μg L-1, respectivamente, os quais foram semelhantes aos obtidos por CVG. Os métodos desenvolvidos para a determinação de Hg e Se por PVG-GF AAS em amostras biológicas são sensíveis, livres de interferência espectral, de baixo custo e representam uma alternativa viável a CVG. / Chemical vapor generation (CVG) and photochemical vapor generation (PVG) are analytical techniques used to convert the analyte into a volatile species in liquid phase, before the introduction into the detection system. In this study, analytical procedures for the determination of Hg and Se in biological samples by vapor generation techniques coupled to graphite furnace atomic absorption spectrometry (GF AAS) were developed. Accurate Hg determination in fish samples was possible after a solubilization in tetramethylammonium hydroxide and adding n-propanol, as low molecular organic compound, using PVG-GF AAS. The developed method for Se determination in coconut water with PVG-GF AAS have resulted in limits of detection and quantification of 0,65 μg L-1 and 2,2 μg L-1, respectively and that were similar with those obtained with CVG. The developed methods for Hg and Se determination in biological samples using PVG-GF AAS are sensitive, free of spectral interference, low-cost, and are a feasible alternative for CVG.
29

Desenvolvimento de métodos analíticos para determinação de elementos traço em materiais poliméricos utilizando amostragem sólida por espectrometria de absorção atômica em forno de grafite

Duarte, Álvaro Tavares January 2010 (has links)
A União Europeia ao adotar as diretivas: 2002/96/EC — WEEE e a 2002/95/EC — RoHS de modo a minimizar os resíduos equipamentos eletroeletrônicos (WEEE — do inglês: Waste Eletrical Electronic Equipment) e restringir as substancias nocivas (RoHS — do inglês: Restriction of Hazardous Substances) vem causando um grande impacto na rotina de controle de substancias perigosas, incluindo metais taco tóxicos, como chumbo, cadmio e cromo, em todos os materiais que são utilizados nesses equipamentos. Os componentes plásticos são os principais constituintes dos equipamentos eletrônicos e uma potencial fonte de metais taco tóxicos que são adicionados como estabilizantes, corantes e catalisadores. Como esses materiais plásticos são desenvolvidos de modo a serem resistentes a ataques químicos, eles são normalmente difíceis de serem dissolvidos. Sob esta motivação, neste trabalho foram desenvolvidos e otimizados métodos para a determinação de cadmio, chumbo e cromo utilizando a técnica de amostragem direta de sólidos por espectrometria de absorção atômica com forno de grafite. Em todos os procedimentos o foco principal foi a redução de tratamento das amostras, bem como o emprego de soluções padrão aquosas a fim de tornar os métodos mais simples e facilmente aplicáveis a rotina. O use de modificador químico, mistura de paládio e magnésia foi mandatório para estabilizar cadmio e chumbo. As determinações de cromo foram realizadas sem a adição de modificador químico. Calibração versus padrões aquosos Ode ser utilizada para a determinação dos três analitos. Nas determinações de chumbo e de cromo de modo a ter uma maior faixa linear de concentração usou-se o artificio de trabalhar com ou sem fluxo de gás na etapa de atomização. No caso da determinação de cadmio linhas analíticas (228,8 nm e 326,1 nm) com diferentes sensibilidades foram empregadas para ampliar a faixa linear do método. Os limites de detecção foram: 0,7 lig kg-1, 22 prg kg1 e 13 jig kg-1 para cadmio, chumbo e cromo, respectivamente. Materiais de referencia certificados foram utilizados para a validação dos métodos, não havendo diferença significativa entre os valores obtidos e os certificados. Oito amostras de resíduos de equipamentos eletroeletrônicos foram analisadas, estando todas em conformidade com as diretivas WEEE e RoHS. / By adopting the directives 2002/96/EC — WEEE (Waste Eletrical and Electronic Equipment) and 2002/95/EC — RoHS (Restriction of Hazardous Substances) the European Union will cause a great impact on the routine control of hazardous substances, including toxic trace metals, such as lead, cadmium and chromium, in all the materials that are used in this kind of equipment. Plastic components are among the main constituents of electronic equipment and a potential source of toxic trace metals, which are added as stabilizers, catalysts and/or colorant. As these plastic materials are designed to be resistant against chemical attack, they are usually very difficult to bring into solution. Because of that, methods have been developed and optimized in this work for the determination of cadmium, lead and chromium using direct solid sampling graphite furnace atomic absorption spectrometry. The primary aspects in all all method development have been reduction of sample treatment and the use of aqueous Standards for calibration in order to make methods simple and easily applicable in routine. The use of a mixture of palladium and magnesium as a chemical modifier was found to be mandatory for the determination of cadmium and lead, whereas no modifier was necessary for the determination of chromium. Calibration against aqueous standards could be used for all three analytes. In order to increase the linear working range for the determination of chromium and lead, the determination has been carried out with the internal gas flow turned off and on, respectively, during atomization. In the case of cadmium, the analytical lines at 228.8 nm and 326.1 nm, respectively, with significantly different sensitivities were used for that purpose. The detection limits were 0.7 p.g kg', 22 pig kg-1 and 13 !,ig kg-1 for cadmium, lead and chromium, respectively. Certified reference materials were used for validation of the methods, and there was no significant difference between the found and the certified values. Eight samples of residues of electronic equipment have been analyzed, and all of them were within the limits of the directives of WEEE and RoHS.
30

Estratégias de análise direta de amostras para determinação de elementos traço em biomassa e seus produtos de pirólise por espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite

Duarte, Álvaro Tavares January 2014 (has links)
No presente trabalho foi investigada a viabilidade da aplicação da técnica de análise direta (com mínimo preparo de amostra) por espectrometria de absorção atômica de alta resolução com fonte continua e fomo de grafite (DS-HR-CS GF AAS). Métodos foram desenvolvidos para a determinação de chumbo, cádmio e cromo em amostras de biomassa, bio-óleo, água de pirólise e cinzas de biomassa (obtidos através de processo de pirólise ). As determinações foram realizadas sem adição de modificador quimico e utilizando calibração com soluções padrão aquosas. A determinação de cádmio e cromo foi realizada de maneira sequencial, ou seja, feita somente uma pesagem de amostra para determinação dos dois elementos, que possibilita trabalhar com uma menor quantidade de amostra e aumenta a velocidade analítica do método. Os métodos desenvolvidos se mostraram sensíveis, exatos, precisos e aplicáveis à rotina, com exceção do método desenvolvido para determinação sequencial de cádmio e cromo em amostras de bio-óleo, que apresentou limitações para determinação de cádmio. Após a determinação desses metais nas amostras analisadas, foi realizado um balanço de massas e estimado que a maior parte de chumbo e cromo presente na biomassa é eliminada para o ambiente durante o processo de pirólise, ficando uma parte significante retida nas cinzas. / In this work was investigated the feasibility of applying the technique of direct analysis (with a minimum sample preparation) by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS DS-GF AAS). Methods have been developed for the determination o f lead, cadmium and chromium in biomass, bio-oil, the aqueous phase o f the pyrolysis, and biomass ashes ( obtained by the pyrolysis process ). Ali measurements were performed without chemical modifier and using aqueous standard solutions for calibration. The determination of cadmium and chromium was performed in a sequential mode, determining both elements from the same sample aliquot, which allows work:ing with a small quantity of sample and increases the speed of the analytical method. The developed methods were sensitive, accurate and applicable to routine, with the exception of the method for sequential determination of cadmium and chromium in bio-oil, which presented lirnitations for the determination of cadmium. After determination ofthese metais in the samples, a mass balance was performed and estimated that most of the lead and chromium present in the biomass were emitted to the environment during the pyrolysis process, with a significant portion retained in the ashes.

Page generated in 0.0541 seconds