• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 10
  • 6
  • 2
  • 2
  • Tagged with
  • 47
  • 47
  • 21
  • 15
  • 12
  • 10
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Resistencia a la fractura de premolares según el diseño de cavidad de acceso endodóntico. Estudio in vitro

Arias Moreno, Mauricio Alonso January 2024 (has links)
La preparación de la cavidad de acceso es el primer paso y un requisito esencial, para la instrumentación y obturación de los conductos radiculares durante el tratamiento endodóntico. El objetivo del presente estudio fue comparar la resistencia a la fractura in vitro de premolares con cavidad de acceso tradicional (CAT), cavidad de acceso conservador (CAC) y cavidad de acceso ultraconservador (CAU). Esta fue una investigación transversal, prospectiva y experimental pura. Se realizó con 40 segundos premolares superiores, divididos en 4 grupos. Todas las muestras fueron desinfectadas y almacenadas en recipientes con suero fisiológico al 0.9%. Al primer grupo se designó como el control, al segundo grupo CAT, al tercer grupo CAC y al cuarto grupo CAU. Se realizaron todos los accesos endodónticos con una pieza de mano de alta velocidad con refrigeración respetando el protocolo de cada uno de los diseños, posterior a ello se realizó el tratamiento endodóntico y restauración de los especímenes. Una vez preparadas todas las muestras, estas fueron sometidas a una prueba de fatiga en una máquina de ensayo universal y los resultados se registraron en Newtons. La prueba estadística usada fue ANOVA con un nivel de significancia de 5 %. Las CAT obtuvieron el menor valor de resistencia y fueron diferentemente significativas al grupo control. Además, CAC y CAU no obtuvieron valores de resistencia significativos en comparación con CAT.
42

INVESTIGATION OF THE FRACTURE RESISTANCE OF PAPER UTILIZING A MODIFIED LINEAR ELASTIC FRACTURE MECHANICS MODEL

Li, Ji 06 August 2015 (has links)
No description available.
43

Resistencia a la fractura de dientes con reabsorción radicular interna reparadas con diferentes selladores de conductos radiculares: estudio in vitro

Flores Mejia, Jose Orlando January 2024 (has links)
El objetivo del presente estudio fue determinar in vitro que grupo de dientes analizados con reabsorción radicular interna tratados endodónticamente y reparados con tres distintos selladores presentó la mayor resistencia a la fractura. Metodología, el estudio fue de nivel básica; de tipo prospectivo, longitudinal y exploratorio; de diseño experimental in vitro; y de enfoque cuantitativo. La población, estuvo conformada por piezas dentarias del grupo premolar mandibulares y de un sólo conducto radicular; la muestra, fue conformada de manera no aleatoria por conveniencia, constituida por 60 piezas dentarias, divididas en seis grupos de 10 dientes cada uno (A: Biodentine + Biodentine, B: Biodentine + gutapercha + Neo Sealer, C: Neo Putty + Neo Putty, D: Neo Putty + gutapercha + cemento Neo sealer, grupo control positivo y grupo control negativo); asimismo, se consideró los criterios de inclusión y exclusión. Para la medición de la resistencia a la fractura se utilizó la máquina universal Instron, en el Laboratorio High Technology Laboratory Certificate S.A.C, San Juan de Lurigancho – Lima, 2023. Resultados, se halló que la resistencia a la fractura promedio de los grupos control positivo y negativo fueron 558.147N y 648.212N, respectivamente; y, la resistencia a la fractura promedio en los grupos experimentales fueron los siguientes: 485.938N para el grupo D, 419.382N para el grupo A, 410.417N para el grupo C y 407.824N para el grupo B. Además, se mostró que existe diferencia significativa entre las medias resistencia a la fractura de los dientes de los grupos experimentales con respecto a los grupos controles, pues los grupos controles tuvieron un mayor rango promedio de la resistencia a la fractura que los dientes tratados con los sellantes endodónticos (p-valor = 0.002, p<0.05). Conclusión, se concluyó que entre los grupos experimentales, el grupo sellador Neo Putty + gutapercha + sellador Neo Sealer fue aquel que mostró la mayor resistencia a la fractura en los dientes con reabsorción radicular interna tratados endodónticamente; sin embargo, esta resistencia fue menor a la hallada en los grupos controles.
44

Avaliação da adaptação marginal e interna, da resistência à fratura após ciclagem termomecânica e das tensões nos implantes por correlação de imagens digitais em próteses parciais fixas sobre implantes com pilares e copings em zircônia com diferentes sistemas CAD/CAM / Evaluation of the marginal and internal fit, resistance to fracture after thermomechanical cycling and tensions in the implants by correlation of digital images in fixed partial dentures on implants with abutments and copings in zirconia with different CAD/CAM systems

Mendes, Francielle Alves 02 June 2015 (has links)
Considerando a crescente exigência estética, o desenvolvimento da zircônia e o incremento da tecnologia CAD/CAM o objetivo deste trabalho foi avaliar a adaptação marginal e interna, as tensões nos implantes e a resistência à fratura após prensagem da porcelana e termociclagem mecânica em próteses parciais fixas sobre implantes com pilares e infraestrutura em zircônia com dois sistemas CAD/CAM (Neodent digital - Neodent e Lava - 3M ESPE) comparados com o método convencional (n=10). A adaptação marginal e interna foi analisada por meio de um microtomógrafo computadorizado (microCT). Cada prótese foi digitalizada e os arquivos foram processadas utilizando o software NRecon e CTAN. Foi utilizado o programa Dataview para aferição das medidas. Para a realização da ciclagem termomecânica as próteses foram posicionadas na máquina de fadiga mecânica por mastigação e foi aplicada a carga de 120 N com uma ponta que simula a oclusão antagonista simulando 2.000.000 ciclos. Durante o ensaio, as próteses foram mantidas em água destilada e termocicladas com variação de temperatura entre 5º-55º C. Para a verificação das tensões geradas pelas próteses parciais fixas em torno dos implantes foi realizada a análise por correlação de imagens digitais. Foram selecionados cinco modelos de cada um dos sistemas CAD/CAM e um antagonista e aplicada uma carga de 250 N, com velocidade de 0,1 mm/min, em máquina universal de ensaios. Para avaliação da resistência à fratura foi aplicada uma força perpendicular ao longo eixo da peça protética, no pôntico, até que devido à fratura não houvesse mais resistência. Após esse teste foi avaliado o relacionamento entre os componentes da prótese em microscópio eletrônico de varredura (MEV). A análise estatística mostrou que houve diferença significativa na adaptação pilar-implante dos molares entre os grupos Lava e ZirNeo, Lava e Controle (p=0,008). Para a desadaptação vertical e horizontal antes e após a prensagem e ciclagem não houve diferença significante (p>0,005). A desadaptação interna axial mostrou diferença significante antes e após para os molares dos grupos Lava e ZirNeo (p<0,001). A desadaptação interna oclusal mostrou diferença significante para os PM dos grupos TiNeo e Controle e para os molares dos grupos Lava e Zir Neo (p<0,005). Houve diferença significante de tensão na região cervical dos molares dos grupos ZirNeo e Lava (p=0,015) com maiores valores de tensão para o grupo Lava. O grupo TiNeo teve maior resistência à fratura que os demais (p=0,022). O relacionamento entre os componentes da prótese permaneceu favorável para todos os grupos. Os resultados deste trabalho permitem concluir que a prensagem da porcelana e a termociclagem mecânica não influenciou os resultados da desadaptação marginal e melhorou a desadaptação interna. O grupo usinado pelo sistema Neodent digital em zircônia teve maior concentração de tensão na região cervical podendo ter maior perda óssea nessa região. O grupo TiNeo foi o que mais resistiu à fratura. Entre fresar em zircônia pelo sistema Neodent digital ou Lava, o sistema Lava distribui melhor a tensão ao longo do implante, porém teve maiores valores de desadaptação interna. Entre fresar em titânio ou confeccionar a prótese pelo sistema convencional, melhor fresar. / Considering the growing aesthetic requirements, the development of zirconia and the increase of CAD/CAM technology, the aim of this study was to evaluate the marginal and internal fit, tensions in implants and fracture resistance after pressing porcelain and thermomechanical cycling in FPDs on implants with abutments and infrastructure in zirconia with two CAD/CAM systems (Neodent digital -Neodent and Lava - 3M ESPE) compared with the conventional method (n = 10). The marginal and internal fit was analyzed by a computerized microtomograph (microCT). Each prosthesis was scanned and the files were processed using the NRecon and CTAN software. Dataview program was used for the assessment of the measures. To carry out the thermomechanical cycling, prostheses were placed in mechanical fatigue machine for chewing and 120 N load was applied with a tip that simulates the antagonist occlusion simulating 2,000,000 cycles. During the test, the prostheses were kept in distilled water and thermocycled with temperatures between 5°-55° C. Digital image correlation analysis was performed to check the load transfer by implant-supported restoration. Five models were selected from each of the CAD/CAM systems and an antagonist and a load of 250 N was applied, with 0.1 mm/min speed using a universal testing machine. The fracture resistance was verified with force applied perpendicular to the long axis of the prosthesis, at pontic, until there were no more fracture resistance. After this test was evaluated the relationship between the components of the prosthesis in a scanning electron microscope (SEM). The statistical analysis showed significant difference in abutment-implant fit of molars between Lava and ZirNeo, Lava and control groups (p=.008). For vertical and horizontal fit there was no significant difference (p>.005) before and after pressing and thermomechanical cycling. The axial internal gap was significantly different before and after for molar ZirNeo groups (p<.001). The occlusal internal fit was significantly different to the PM of TiNeo and Control, and the molars of Lava and ZirNeo (p<.005). There were significant difference for tension in the cervical region of the molars of ZirNeo and Lava (p=.015) with higher values for the Lava group. TiNeo group had higher resistance to fracture than others (p=.022). The relationship between the prosthesis components remained positive for all groups. The results of this study showed that the pressing of porcelain and thermomechanical cycling did not influence the results of marginal gap and improved internal fit. The zirconia group machined by Neodent digital system had higher concentration of tension in the cervical and may have greater bone loss in this region. TiNeo group was the most resistant to fracture. Between the zirconia milling by Neodent digital or Lava system, the Lava system distributes better strain throughout the implant, but had greater internal fit values. Between milling titanium or fabricate the prosthesis by the conventional system, better milling.
45

INFLUÊNCIA DA ADAPTAÇÃO DE PINOS DE FIBRA E DE TÉCNICAS RESTAURADORAS ALTERNATIVAS PARA PREENCHIMENTO DE CANAIS RADICULARES EXCESSIVAMENTE ALARGADOS / Influence of fiber posts adaptation and alternative restorative techniques for flared root canal filling

Gomes, Giovana Mongruel 20 September 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:29Z (GMT). No. of bitstreams: 1 Giovana Mongruel Gomes.pdf: 3752517 bytes, checksum: 6acad02e468853d81d1d9172fd003844 (MD5) Previous issue date: 2013-09-20 / The objectives of this study were 1) to evaluate the effect of the influence of the resin cement thickness (RCT) on bond strength (BS) and gap formation (GF) between glass fiber post (FP) and root dentin and 2) to evaluate the BS and fracture resistance (FR) of restorative techniques for filling oversized root canals. In experiment 1, the roots of 24 mandibular premolars (n=8 per group) were endodontically treated. After one week, the post spaces were prepared depending on the post adaptation inside the root canal, simulating an ideal adaptation (IdAd),medium adaptation (MeAd) and inadequate adaptation (InAd). All posts were cemented with Excite® DSC and Variolink® II. After a week of cementation, the RCT and GF were measured with the Image Tool software version 3.0, and the BS by the push-out test. In experiment 2, the roots of 84 mandibular premolars were endodontically treated and, after a week, the conduits were prepared in order to simulate an oversized root canal, except for the positive control group (PC), which was cemented one prefabricated fiber post (PFP) with the diameter compatible with the conduit. In the other oversized root canals, alternative restorative techniques for filling root canals were tested: NC - negative control (PFP with a smaller diameter than of the root canal), PA - PFP + accessory posts, DAP – direct anatomical post,IAP – indirect anatomical post and RR – root reinforcement with composite resin. All posts were cemented with the same adhesive system and resin cement. After indirect composite crowns cementation, the teeth were submitted to mechanical fatigue (1.2 X 106 cycles, 40 N) before the push-out BS test (n=8) and the FR test (n=6). The data of experiments 1 and 2 were analyzed by ANOVA and paired test (α=0.05). The experiment 1 showed that the smaller RCT resulted in better fiber post adhesion, that is, higher BS and lower GF. The experiment 2 showed that the use of direct and indirect anatomical posts resulted in the best performance both in BS and FR tests,and must be the first choice for FP cementation in flared roots with oversized root canals. Therefore, we concluded that the post adaptation to root canal affected significantly its retention. The better the post adaptation, the better the laboratory results. However, in the absence of this ideal condition, the use of direct and indirect anatomic posts should be the first choice for restoring flared root canals. / Os objetivos deste estudo foram 1) avaliar o efeito da influência da espessura de cimento resinoso (ECR) na resistência de união (RU) e na formação de gaps (FG) entre pino de fibra de vidro (PFV) e dentina radicular e 2) avaliar a RU e resistência à fratura (RF) de técnicas restauradoras para preenchimento de canais radiculares excessivamente alargados. No experimento 1, as raízes de 24 pré-molares inferiores (n=8 por grupo) foram tratadas endodonticamente. Após uma semana, os condutos foram preparados em função da adaptação do pino no canal radicular, simulando uma adaptação ideal (AdId), média (AdMe) e inadequada (AdIn). Todos os pinos foram cimentados com Excite® DSC e Variolink® II. Uma semana após a cimentação, a ECR e a FG foram mensuradas com o software Image Tool versão 3.0 e a RU por meio do teste de push-out. No experimento 2, as raízes de 84 pré-molares inferiores foram tratadas endodonticamente e, após uma semana, realizou-se o preparo dos condutos, de maneira a simular um canal radicular excessivamente alargado, com exceção do grupo controle positivo (GCP), em que foi cimentado um pino préfabricado (PPF) com calibre compatível ao diâmetro do conduto. Nos outros condutos alargados, técnicas restauradoras alternativas de preenchimento dos canais radiculares foram empregadas: GCN – grupo controle negativo (PPF de diâmetro inferior ao conduto), GPA – PPF + pinos acessórios, GAD – pino anatômico direto, GAI – pino anatômico indireto e GRR – reforço radicular com resina composta + PPF. Todos os pinos foram cimentados com o mesmo sistema adesivo e cimento resinoso. Após cimentação de coroas de resina indireta, os dentes foram submetidos à fadiga mecânica (1,2 x 106 ciclos, 40 N) antes de realizar o teste de RU (n=8) e de RF (n=6). Os dados do experimento 1 e 2 foram analisados por ANOVA e teste pareado (α=0,05). O experimento 1 mostrou que quanto menor a ECR melhor a adesão dos PFV, ou seja, maior a RU e menor a FG. O experimento 2 mostrou que o uso de pinos anatômicos diretos e indiretos mostrou o melhor desempenho nos testes de RU e RF, e deve ser primeira opção para cimentação de PFV em canais radiculares alargados. Portanto, foi evidenciado que a adaptação do pino ao conduto radicular influenciou significativamente na retenção dos mesmos; quanto mais justa,melhores resultados laboratoriais. Entretanto, na ausência desta condição ideal, o uso de pinos anatômicos diretos e indiretos pode ser a primeira escolha do clínico para tratamento de canais excessivamente alargados. Palavras-chave: cimentos resinosos, dentina radicular, gap, microscopia eletrônica de varredura, pinos de fibra, raízes enfraquecidas, resistência à fratura, resistência de união.
46

[en] APPLICATION OF J-INTEGRAL IN STEELS OF DIFFERENT YIELD LIMITS / [pt] APLICAÇÃO DA INTEGRAL-J EM AÇOS DE DIFERENTES LIMITES DE ESCOAMENTO

THAIS MOTTA DA SILVA 28 January 2019 (has links)
[pt] O estudo da resistência à fratura dos materiais é de grande importância para desenvolvimentos de projetos, seleção de materiais e avaliação do comportamento dos materiais perante a presença de um defeito no componente. Há inúmeras normas que envolvem geometrias padronizadas para determinação desta propriedade mecânica, no entanto nem todo componente em serviço possui as mesmas condições encontradas nas geometrias padronizadas, como é o caso de materiais dúcteis empregados em estruturas com espessuras de paredes finas e elevada pressão interna. Nesta dissertação foram estudados dois materiais com diferentes limites de escoamento confeccionados conforme geometria tipo SEN(T) de fixação por garras, a qual não é padronizada pela ASTM. Com isso, foi realizada uma pesquisa com o emprego desta geometria com variação de 0,2 a 0,8 da relação entre a dimensão idealizada inicialmente para a trinca e a largura do corpo de prova, e entalhes laterais com redução de 20 porcento foram confeccionados nos corpos de prova do material mais dúctil. Após, foi realizada a pré-trinca de fadiga e iniciado o ensaio de tenacidade à fratura. Este último foi desenvolvido adotando o método compliance, o qual permite que com apenas um corpo de prova seja realizado descarregamentos parciais permitindo assim a determinação de J e incremento de trinca em cada posição, possibilitando plotar a curva-R Os resultados obtidos determinaram que mesmo com a/W diferente daqueles indicados por norma para levantamento da curva-R, é possível obter uma curva-R para a/W=0,2. Existe uma limitação em aplicar a geometria SEN(T) que não possuem extensa ductilidade. / [en] The study of resistance to fracture of the materials is very important for developing new projects, making materials specifications and also for evaluating materials behaviour under presence of a crack in a component. There are uncountables standards which apply normalized specimens due to determine this mechanical property, however some components in service doesn t act under same conditions as the specimen chosen, for instance ductile materials applied in components with thin thickness and high intern pressure. In this dissertation was studied two diferente of materials with distinct yield limits fabricated according to SEN(T) geometry with clamped fixing, which one is not acceptable by ASTM. Thus, a research has been carried out using this geomerty with a variation of 0,2 to 0,8 of the relation between the idealized initially for the crack and the width of the proof body ratio and side-grooves with 20 percent reducted were made in the specimens with higher ductility. After that, the procedure for doing fatigue pre-crack was initialized, followed by fracture toughness test. This last one was developed adopting the unloading compliance technique, which one allows that more than one aplications of force and displacement can be realized in only one specimen then the value of J and crack extension can be calculated and the R-curve will be plotted. The results obtained showed even with a a/W ratio diferente of those indicated by standards, is possible to constructo a qualified R-curve for a/W=0,2. In additon to the results, there is a limitation in applying a SEN(T) geometry in materials that don t present extensive ductility.
47

Avaliação da adaptação marginal e interna, da resistência à fratura após ciclagem termomecânica e das tensões nos implantes por correlação de imagens digitais em próteses parciais fixas sobre implantes com pilares e copings em zircônia com diferentes sistemas CAD/CAM / Evaluation of the marginal and internal fit, resistance to fracture after thermomechanical cycling and tensions in the implants by correlation of digital images in fixed partial dentures on implants with abutments and copings in zirconia with different CAD/CAM systems

Francielle Alves Mendes 02 June 2015 (has links)
Considerando a crescente exigência estética, o desenvolvimento da zircônia e o incremento da tecnologia CAD/CAM o objetivo deste trabalho foi avaliar a adaptação marginal e interna, as tensões nos implantes e a resistência à fratura após prensagem da porcelana e termociclagem mecânica em próteses parciais fixas sobre implantes com pilares e infraestrutura em zircônia com dois sistemas CAD/CAM (Neodent digital - Neodent e Lava - 3M ESPE) comparados com o método convencional (n=10). A adaptação marginal e interna foi analisada por meio de um microtomógrafo computadorizado (microCT). Cada prótese foi digitalizada e os arquivos foram processadas utilizando o software NRecon e CTAN. Foi utilizado o programa Dataview para aferição das medidas. Para a realização da ciclagem termomecânica as próteses foram posicionadas na máquina de fadiga mecânica por mastigação e foi aplicada a carga de 120 N com uma ponta que simula a oclusão antagonista simulando 2.000.000 ciclos. Durante o ensaio, as próteses foram mantidas em água destilada e termocicladas com variação de temperatura entre 5º-55º C. Para a verificação das tensões geradas pelas próteses parciais fixas em torno dos implantes foi realizada a análise por correlação de imagens digitais. Foram selecionados cinco modelos de cada um dos sistemas CAD/CAM e um antagonista e aplicada uma carga de 250 N, com velocidade de 0,1 mm/min, em máquina universal de ensaios. Para avaliação da resistência à fratura foi aplicada uma força perpendicular ao longo eixo da peça protética, no pôntico, até que devido à fratura não houvesse mais resistência. Após esse teste foi avaliado o relacionamento entre os componentes da prótese em microscópio eletrônico de varredura (MEV). A análise estatística mostrou que houve diferença significativa na adaptação pilar-implante dos molares entre os grupos Lava e ZirNeo, Lava e Controle (p=0,008). Para a desadaptação vertical e horizontal antes e após a prensagem e ciclagem não houve diferença significante (p>0,005). A desadaptação interna axial mostrou diferença significante antes e após para os molares dos grupos Lava e ZirNeo (p<0,001). A desadaptação interna oclusal mostrou diferença significante para os PM dos grupos TiNeo e Controle e para os molares dos grupos Lava e Zir Neo (p<0,005). Houve diferença significante de tensão na região cervical dos molares dos grupos ZirNeo e Lava (p=0,015) com maiores valores de tensão para o grupo Lava. O grupo TiNeo teve maior resistência à fratura que os demais (p=0,022). O relacionamento entre os componentes da prótese permaneceu favorável para todos os grupos. Os resultados deste trabalho permitem concluir que a prensagem da porcelana e a termociclagem mecânica não influenciou os resultados da desadaptação marginal e melhorou a desadaptação interna. O grupo usinado pelo sistema Neodent digital em zircônia teve maior concentração de tensão na região cervical podendo ter maior perda óssea nessa região. O grupo TiNeo foi o que mais resistiu à fratura. Entre fresar em zircônia pelo sistema Neodent digital ou Lava, o sistema Lava distribui melhor a tensão ao longo do implante, porém teve maiores valores de desadaptação interna. Entre fresar em titânio ou confeccionar a prótese pelo sistema convencional, melhor fresar. / Considering the growing aesthetic requirements, the development of zirconia and the increase of CAD/CAM technology, the aim of this study was to evaluate the marginal and internal fit, tensions in implants and fracture resistance after pressing porcelain and thermomechanical cycling in FPDs on implants with abutments and infrastructure in zirconia with two CAD/CAM systems (Neodent digital -Neodent and Lava - 3M ESPE) compared with the conventional method (n = 10). The marginal and internal fit was analyzed by a computerized microtomograph (microCT). Each prosthesis was scanned and the files were processed using the NRecon and CTAN software. Dataview program was used for the assessment of the measures. To carry out the thermomechanical cycling, prostheses were placed in mechanical fatigue machine for chewing and 120 N load was applied with a tip that simulates the antagonist occlusion simulating 2,000,000 cycles. During the test, the prostheses were kept in distilled water and thermocycled with temperatures between 5°-55° C. Digital image correlation analysis was performed to check the load transfer by implant-supported restoration. Five models were selected from each of the CAD/CAM systems and an antagonist and a load of 250 N was applied, with 0.1 mm/min speed using a universal testing machine. The fracture resistance was verified with force applied perpendicular to the long axis of the prosthesis, at pontic, until there were no more fracture resistance. After this test was evaluated the relationship between the components of the prosthesis in a scanning electron microscope (SEM). The statistical analysis showed significant difference in abutment-implant fit of molars between Lava and ZirNeo, Lava and control groups (p=.008). For vertical and horizontal fit there was no significant difference (p>.005) before and after pressing and thermomechanical cycling. The axial internal gap was significantly different before and after for molar ZirNeo groups (p<.001). The occlusal internal fit was significantly different to the PM of TiNeo and Control, and the molars of Lava and ZirNeo (p<.005). There were significant difference for tension in the cervical region of the molars of ZirNeo and Lava (p=.015) with higher values for the Lava group. TiNeo group had higher resistance to fracture than others (p=.022). The relationship between the prosthesis components remained positive for all groups. The results of this study showed that the pressing of porcelain and thermomechanical cycling did not influence the results of marginal gap and improved internal fit. The zirconia group machined by Neodent digital system had higher concentration of tension in the cervical and may have greater bone loss in this region. TiNeo group was the most resistant to fracture. Between the zirconia milling by Neodent digital or Lava system, the Lava system distributes better strain throughout the implant, but had greater internal fit values. Between milling titanium or fabricate the prosthesis by the conventional system, better milling.

Page generated in 0.0951 seconds