• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e barra articulada / Evaluation of two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar

Silva, Rafael Cândido Pedroso e 27 January 2016 (has links)
O objetivo deste estudo foi avaliar dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e Barra Articulada. Após ciclagem termomecânica, foram analisadas a perda de torque dos parafusos protéticos e adaptação marginal vertical e horizontal. Ao final, as próteses foram submetidas a ensaios de fadiga acelerada progressiva e resistência à fratura. Foram confeccionadas 48 próteses totais fixas implantossuportadas, as quais foram divididas inicialmente em dois grupos, G1 protocolo convencional; G2 - &ldquo;All-on-4&rdquo;. De acordo com a técnica de fabricação das infraestruturas, estes grupos foram divididos em três subgrupos, A - tecnologia CAD-CAM; B - fundição convencional; C - Barra Articulada, proporcionando seis amostragens diferentes: G1A, G1B, G1C, G2A, G2B e G2C (n=8). Todas as próteses foram avaliadas em relação à adaptação marginal vertical e horizontal, utilizando MicroCT, antes e após a ciclagem termomecânica (2.000.000 de ciclos). A perda de torque dos parafusos protéticos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). Após este ensaio, as próteses foram submetidas ao teste de fadiga acelerada progressiva (n=8) e em sequência, ensaio de resistência à fratura (n=6). A perda de torque teve diferença significante para todos os tempos comparados (p<0,01), exceto em G2B, onde a comparação entre T1 - T2 não mostrou diferença significante (p=0,72). A comparação entre G1 e G2 não foi significante. A comparação entre os subgrupos A, B e C teve diferenças significantes em G1T1, G1T2, G2T1 e G2T2 quando comparados os subgrupos A - B e B - C, todos com (p<0,01). Não houve diferenças significantes para a adaptação marginal vertical e horizontal antes e depois da ciclagem em todos os grupos. Na comparação de G1 e G2, houve diferença significante para a adaptação vertical e horizontal apenas no subgrupo B, nos dois tempos, ambos com (p <0,01). Na comparação dos subgrupos A, B e C, houve diferenças significantes em G1 antes e depois; e G2 antes e depois, quando comparados os subgrupos A - B e B - C, todos com (p<0,01) para a adaptação vertical e horizontal. Já para a adaptação horizontal, esta comparação foi significante apenas em G2 antes e depois, ambos com (p=0,02). Em relação à resistência à fratura, a comparação entre G1 e G2, foi significante em todos os subgrupos, A e C (p<0,01), B (p=0,02). A comparação dos subgrupos A, B e C, também foi significante em relação à resistência à fratura das próteses em todos os grupos (p<0,01). Pode-se concluir que a simulação de ciclos mastigatórios teve influência significante sobre a perda de torque dos parafusos protéticos, porém não influenciou significativamente a adaptação marginal vertical e horizontal das próteses; desadaptações marginais influenciaram significativamente no afrouxamento dos parafusos protéticos; as próteses dos subgrupos A e C obtiveram resultados significantemente melhores para a adaptação marginal vertical e horizontal quando comparadas às do subgrupo B, sendo que na adaptação horizontal, as do subgrupo A tiveram resultados melhores que as do C; a quantidade e distribuição dos implantes não influenciou na perda de torque dos parafusos protéticos em todas as situações, porém teve influência significativa na adaptação marginal vertical e horizontal das próteses do subgrupo B; todas as próteses sobreviveram ao ensaio de fadiga acelerada progressiva; em relação ao ensaio de resistência à fratura, as próteses do G2, tiveram resultados significantemente melhores que as do G1, o subgrupo B obteve valores significantemente maiores de resistência na região do cantilever, quando comparadas ao subgrupos A e C; o subgrupo A obteve os menores valores de resistência. / The objective of this study was evaluate two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar. After thermomechanical cycling, were analyzed prosthetic screws loosening and vertical and horizontal marginal adaptation. In the end, the prostheses were submitted to tests of progressive accelerated fatigue and fracture resistance. Were made 48 implant-supported fixed dentures, which initially were divided into two groups, G1 - conventional protocol; G2 - \"All-on-4\". According to the technique of manufacturing infrastructure, these groups were divided into three subgroups: A - CAD-CAM technology; B - conventional casting; C - Articulated bar, providing six different samples: G1A, G1B, G1C, G2A, G2B e G2C (n=8). All samples were evaluated in the vertical and horizontal marginal adaptation using MicroCT before and after the thermomechanical cycling (2,000,000 cycles). The loosening of the prosthetic screws was analyzed before (T0), 1,000,000 (T1) and 2,000,000 cycles (T2). After this test, the prostheses were submitted to progressive accelerated fatigue test (n = 8) and sequentially fracture resistance test (n = 6). The prosthetic screw loosening has significant difference for all time compared (p <0.01), except in G2B where the comparison between T1 - T2 showed no significant difference (p = 0.72). The comparison between G1 and G2 was not significant. The comparison between subgroups A, B and C had significant differences in G1T1, G1T2, G2T1 and G2T2 compared subgroups A - B, B - C, all of (p <0.01). There were no significant differences for vertical and horizontal marginal adaptation before and after cycling in all groups. Compared to G1 and G2, there was a significant difference for vertical and horizontal adjustment only in the subgroup B in two stages, both (p <0.01). In the comparison of subgroups A, B and C, there were significant differences G1 before and after; and G2 before and after, when compared subgroups A - B, B - C, all of (p <0.01) for vertical and horizontal adaptation. As for the horizontal adaptation, this comparison was significant only in G2 before and after, with both (p = 0.02). With regard to fracture resistance, the comparison between G1 and G2 was significant in all subgroups, A and C (p <0.01), B (p = 0.02). The comparison of subgroups A, B and C was also significant compared to the fracture resistance of the prosthesis in all groups (p <0.01). It can be concluded that the simulation of mechanical cycling had significant influence on the loosening of prosthetic screws, but did not significantly influence the vertical and horizontal marginal fit of the prosthesis; marginal adaptation significantly influenced the loosening of prosthetic screws; the prostheses of the subgroups A and C had significantly better results for the vertical and horizontal marginal adaptation when compared to the subgroup B, and in the horizontal adaptation, the sub-group A had better results than those of C; the amount and distribution of the implants did not affect the prosthetic screws loosening in all situations, but had significantly influence in vertical and horizontal marginal adaptation of subgroup B prostheses; all samples survived in progressive accelerated fatigue test; in relation to the fracture resistance test, the prosthesis G2, had significantly better results than the G1, the B subgroup achieved significantly higher values of resistance in the cantilever region, when compared to subgroups A and C; the subgroup C obtained the smallest resistance.
2

Avaliação de dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e barra articulada / Evaluation of two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar

Rafael Cândido Pedroso e Silva 27 January 2016 (has links)
O objetivo deste estudo foi avaliar dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e Barra Articulada. Após ciclagem termomecânica, foram analisadas a perda de torque dos parafusos protéticos e adaptação marginal vertical e horizontal. Ao final, as próteses foram submetidas a ensaios de fadiga acelerada progressiva e resistência à fratura. Foram confeccionadas 48 próteses totais fixas implantossuportadas, as quais foram divididas inicialmente em dois grupos, G1 protocolo convencional; G2 - &ldquo;All-on-4&rdquo;. De acordo com a técnica de fabricação das infraestruturas, estes grupos foram divididos em três subgrupos, A - tecnologia CAD-CAM; B - fundição convencional; C - Barra Articulada, proporcionando seis amostragens diferentes: G1A, G1B, G1C, G2A, G2B e G2C (n=8). Todas as próteses foram avaliadas em relação à adaptação marginal vertical e horizontal, utilizando MicroCT, antes e após a ciclagem termomecânica (2.000.000 de ciclos). A perda de torque dos parafusos protéticos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). Após este ensaio, as próteses foram submetidas ao teste de fadiga acelerada progressiva (n=8) e em sequência, ensaio de resistência à fratura (n=6). A perda de torque teve diferença significante para todos os tempos comparados (p<0,01), exceto em G2B, onde a comparação entre T1 - T2 não mostrou diferença significante (p=0,72). A comparação entre G1 e G2 não foi significante. A comparação entre os subgrupos A, B e C teve diferenças significantes em G1T1, G1T2, G2T1 e G2T2 quando comparados os subgrupos A - B e B - C, todos com (p<0,01). Não houve diferenças significantes para a adaptação marginal vertical e horizontal antes e depois da ciclagem em todos os grupos. Na comparação de G1 e G2, houve diferença significante para a adaptação vertical e horizontal apenas no subgrupo B, nos dois tempos, ambos com (p <0,01). Na comparação dos subgrupos A, B e C, houve diferenças significantes em G1 antes e depois; e G2 antes e depois, quando comparados os subgrupos A - B e B - C, todos com (p<0,01) para a adaptação vertical e horizontal. Já para a adaptação horizontal, esta comparação foi significante apenas em G2 antes e depois, ambos com (p=0,02). Em relação à resistência à fratura, a comparação entre G1 e G2, foi significante em todos os subgrupos, A e C (p<0,01), B (p=0,02). A comparação dos subgrupos A, B e C, também foi significante em relação à resistência à fratura das próteses em todos os grupos (p<0,01). Pode-se concluir que a simulação de ciclos mastigatórios teve influência significante sobre a perda de torque dos parafusos protéticos, porém não influenciou significativamente a adaptação marginal vertical e horizontal das próteses; desadaptações marginais influenciaram significativamente no afrouxamento dos parafusos protéticos; as próteses dos subgrupos A e C obtiveram resultados significantemente melhores para a adaptação marginal vertical e horizontal quando comparadas às do subgrupo B, sendo que na adaptação horizontal, as do subgrupo A tiveram resultados melhores que as do C; a quantidade e distribuição dos implantes não influenciou na perda de torque dos parafusos protéticos em todas as situações, porém teve influência significativa na adaptação marginal vertical e horizontal das próteses do subgrupo B; todas as próteses sobreviveram ao ensaio de fadiga acelerada progressiva; em relação ao ensaio de resistência à fratura, as próteses do G2, tiveram resultados significantemente melhores que as do G1, o subgrupo B obteve valores significantemente maiores de resistência na região do cantilever, quando comparadas ao subgrupos A e C; o subgrupo A obteve os menores valores de resistência. / The objective of this study was evaluate two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar. After thermomechanical cycling, were analyzed prosthetic screws loosening and vertical and horizontal marginal adaptation. In the end, the prostheses were submitted to tests of progressive accelerated fatigue and fracture resistance. Were made 48 implant-supported fixed dentures, which initially were divided into two groups, G1 - conventional protocol; G2 - \"All-on-4\". According to the technique of manufacturing infrastructure, these groups were divided into three subgroups: A - CAD-CAM technology; B - conventional casting; C - Articulated bar, providing six different samples: G1A, G1B, G1C, G2A, G2B e G2C (n=8). All samples were evaluated in the vertical and horizontal marginal adaptation using MicroCT before and after the thermomechanical cycling (2,000,000 cycles). The loosening of the prosthetic screws was analyzed before (T0), 1,000,000 (T1) and 2,000,000 cycles (T2). After this test, the prostheses were submitted to progressive accelerated fatigue test (n = 8) and sequentially fracture resistance test (n = 6). The prosthetic screw loosening has significant difference for all time compared (p <0.01), except in G2B where the comparison between T1 - T2 showed no significant difference (p = 0.72). The comparison between G1 and G2 was not significant. The comparison between subgroups A, B and C had significant differences in G1T1, G1T2, G2T1 and G2T2 compared subgroups A - B, B - C, all of (p <0.01). There were no significant differences for vertical and horizontal marginal adaptation before and after cycling in all groups. Compared to G1 and G2, there was a significant difference for vertical and horizontal adjustment only in the subgroup B in two stages, both (p <0.01). In the comparison of subgroups A, B and C, there were significant differences G1 before and after; and G2 before and after, when compared subgroups A - B, B - C, all of (p <0.01) for vertical and horizontal adaptation. As for the horizontal adaptation, this comparison was significant only in G2 before and after, with both (p = 0.02). With regard to fracture resistance, the comparison between G1 and G2 was significant in all subgroups, A and C (p <0.01), B (p = 0.02). The comparison of subgroups A, B and C was also significant compared to the fracture resistance of the prosthesis in all groups (p <0.01). It can be concluded that the simulation of mechanical cycling had significant influence on the loosening of prosthetic screws, but did not significantly influence the vertical and horizontal marginal fit of the prosthesis; marginal adaptation significantly influenced the loosening of prosthetic screws; the prostheses of the subgroups A and C had significantly better results for the vertical and horizontal marginal adaptation when compared to the subgroup B, and in the horizontal adaptation, the sub-group A had better results than those of C; the amount and distribution of the implants did not affect the prosthetic screws loosening in all situations, but had significantly influence in vertical and horizontal marginal adaptation of subgroup B prostheses; all samples survived in progressive accelerated fatigue test; in relation to the fracture resistance test, the prosthesis G2, had significantly better results than the G1, the B subgroup achieved significantly higher values of resistance in the cantilever region, when compared to subgroups A and C; the subgroup C obtained the smallest resistance.
3

Avaliação da adaptação marginal e interna, da resistência à fratura após ciclagem termomecânica e das tensões nos implantes por correlação de imagens digitais em próteses parciais fixas sobre implantes com pilares e copings em zircônia com diferentes sistemas CAD/CAM / Evaluation of the marginal and internal fit, resistance to fracture after thermomechanical cycling and tensions in the implants by correlation of digital images in fixed partial dentures on implants with abutments and copings in zirconia with different CAD/CAM systems

Mendes, Francielle Alves 02 June 2015 (has links)
Considerando a crescente exigência estética, o desenvolvimento da zircônia e o incremento da tecnologia CAD/CAM o objetivo deste trabalho foi avaliar a adaptação marginal e interna, as tensões nos implantes e a resistência à fratura após prensagem da porcelana e termociclagem mecânica em próteses parciais fixas sobre implantes com pilares e infraestrutura em zircônia com dois sistemas CAD/CAM (Neodent digital - Neodent e Lava - 3M ESPE) comparados com o método convencional (n=10). A adaptação marginal e interna foi analisada por meio de um microtomógrafo computadorizado (microCT). Cada prótese foi digitalizada e os arquivos foram processadas utilizando o software NRecon e CTAN. Foi utilizado o programa Dataview para aferição das medidas. Para a realização da ciclagem termomecânica as próteses foram posicionadas na máquina de fadiga mecânica por mastigação e foi aplicada a carga de 120 N com uma ponta que simula a oclusão antagonista simulando 2.000.000 ciclos. Durante o ensaio, as próteses foram mantidas em água destilada e termocicladas com variação de temperatura entre 5º-55º C. Para a verificação das tensões geradas pelas próteses parciais fixas em torno dos implantes foi realizada a análise por correlação de imagens digitais. Foram selecionados cinco modelos de cada um dos sistemas CAD/CAM e um antagonista e aplicada uma carga de 250 N, com velocidade de 0,1 mm/min, em máquina universal de ensaios. Para avaliação da resistência à fratura foi aplicada uma força perpendicular ao longo eixo da peça protética, no pôntico, até que devido à fratura não houvesse mais resistência. Após esse teste foi avaliado o relacionamento entre os componentes da prótese em microscópio eletrônico de varredura (MEV). A análise estatística mostrou que houve diferença significativa na adaptação pilar-implante dos molares entre os grupos Lava e ZirNeo, Lava e Controle (p=0,008). Para a desadaptação vertical e horizontal antes e após a prensagem e ciclagem não houve diferença significante (p>0,005). A desadaptação interna axial mostrou diferença significante antes e após para os molares dos grupos Lava e ZirNeo (p<0,001). A desadaptação interna oclusal mostrou diferença significante para os PM dos grupos TiNeo e Controle e para os molares dos grupos Lava e Zir Neo (p<0,005). Houve diferença significante de tensão na região cervical dos molares dos grupos ZirNeo e Lava (p=0,015) com maiores valores de tensão para o grupo Lava. O grupo TiNeo teve maior resistência à fratura que os demais (p=0,022). O relacionamento entre os componentes da prótese permaneceu favorável para todos os grupos. Os resultados deste trabalho permitem concluir que a prensagem da porcelana e a termociclagem mecânica não influenciou os resultados da desadaptação marginal e melhorou a desadaptação interna. O grupo usinado pelo sistema Neodent digital em zircônia teve maior concentração de tensão na região cervical podendo ter maior perda óssea nessa região. O grupo TiNeo foi o que mais resistiu à fratura. Entre fresar em zircônia pelo sistema Neodent digital ou Lava, o sistema Lava distribui melhor a tensão ao longo do implante, porém teve maiores valores de desadaptação interna. Entre fresar em titânio ou confeccionar a prótese pelo sistema convencional, melhor fresar. / Considering the growing aesthetic requirements, the development of zirconia and the increase of CAD/CAM technology, the aim of this study was to evaluate the marginal and internal fit, tensions in implants and fracture resistance after pressing porcelain and thermomechanical cycling in FPDs on implants with abutments and infrastructure in zirconia with two CAD/CAM systems (Neodent digital -Neodent and Lava - 3M ESPE) compared with the conventional method (n = 10). The marginal and internal fit was analyzed by a computerized microtomograph (microCT). Each prosthesis was scanned and the files were processed using the NRecon and CTAN software. Dataview program was used for the assessment of the measures. To carry out the thermomechanical cycling, prostheses were placed in mechanical fatigue machine for chewing and 120 N load was applied with a tip that simulates the antagonist occlusion simulating 2,000,000 cycles. During the test, the prostheses were kept in distilled water and thermocycled with temperatures between 5°-55° C. Digital image correlation analysis was performed to check the load transfer by implant-supported restoration. Five models were selected from each of the CAD/CAM systems and an antagonist and a load of 250 N was applied, with 0.1 mm/min speed using a universal testing machine. The fracture resistance was verified with force applied perpendicular to the long axis of the prosthesis, at pontic, until there were no more fracture resistance. After this test was evaluated the relationship between the components of the prosthesis in a scanning electron microscope (SEM). The statistical analysis showed significant difference in abutment-implant fit of molars between Lava and ZirNeo, Lava and control groups (p=.008). For vertical and horizontal fit there was no significant difference (p>.005) before and after pressing and thermomechanical cycling. The axial internal gap was significantly different before and after for molar ZirNeo groups (p<.001). The occlusal internal fit was significantly different to the PM of TiNeo and Control, and the molars of Lava and ZirNeo (p<.005). There were significant difference for tension in the cervical region of the molars of ZirNeo and Lava (p=.015) with higher values for the Lava group. TiNeo group had higher resistance to fracture than others (p=.022). The relationship between the prosthesis components remained positive for all groups. The results of this study showed that the pressing of porcelain and thermomechanical cycling did not influence the results of marginal gap and improved internal fit. The zirconia group machined by Neodent digital system had higher concentration of tension in the cervical and may have greater bone loss in this region. TiNeo group was the most resistant to fracture. Between the zirconia milling by Neodent digital or Lava system, the Lava system distributes better strain throughout the implant, but had greater internal fit values. Between milling titanium or fabricate the prosthesis by the conventional system, better milling.
4

Avaliação da adaptação marginal e interna, da resistência à fratura após ciclagem termomecânica e das tensões nos implantes por correlação de imagens digitais em próteses parciais fixas sobre implantes com pilares e copings em zircônia com diferentes sistemas CAD/CAM / Evaluation of the marginal and internal fit, resistance to fracture after thermomechanical cycling and tensions in the implants by correlation of digital images in fixed partial dentures on implants with abutments and copings in zirconia with different CAD/CAM systems

Francielle Alves Mendes 02 June 2015 (has links)
Considerando a crescente exigência estética, o desenvolvimento da zircônia e o incremento da tecnologia CAD/CAM o objetivo deste trabalho foi avaliar a adaptação marginal e interna, as tensões nos implantes e a resistência à fratura após prensagem da porcelana e termociclagem mecânica em próteses parciais fixas sobre implantes com pilares e infraestrutura em zircônia com dois sistemas CAD/CAM (Neodent digital - Neodent e Lava - 3M ESPE) comparados com o método convencional (n=10). A adaptação marginal e interna foi analisada por meio de um microtomógrafo computadorizado (microCT). Cada prótese foi digitalizada e os arquivos foram processadas utilizando o software NRecon e CTAN. Foi utilizado o programa Dataview para aferição das medidas. Para a realização da ciclagem termomecânica as próteses foram posicionadas na máquina de fadiga mecânica por mastigação e foi aplicada a carga de 120 N com uma ponta que simula a oclusão antagonista simulando 2.000.000 ciclos. Durante o ensaio, as próteses foram mantidas em água destilada e termocicladas com variação de temperatura entre 5º-55º C. Para a verificação das tensões geradas pelas próteses parciais fixas em torno dos implantes foi realizada a análise por correlação de imagens digitais. Foram selecionados cinco modelos de cada um dos sistemas CAD/CAM e um antagonista e aplicada uma carga de 250 N, com velocidade de 0,1 mm/min, em máquina universal de ensaios. Para avaliação da resistência à fratura foi aplicada uma força perpendicular ao longo eixo da peça protética, no pôntico, até que devido à fratura não houvesse mais resistência. Após esse teste foi avaliado o relacionamento entre os componentes da prótese em microscópio eletrônico de varredura (MEV). A análise estatística mostrou que houve diferença significativa na adaptação pilar-implante dos molares entre os grupos Lava e ZirNeo, Lava e Controle (p=0,008). Para a desadaptação vertical e horizontal antes e após a prensagem e ciclagem não houve diferença significante (p>0,005). A desadaptação interna axial mostrou diferença significante antes e após para os molares dos grupos Lava e ZirNeo (p<0,001). A desadaptação interna oclusal mostrou diferença significante para os PM dos grupos TiNeo e Controle e para os molares dos grupos Lava e Zir Neo (p<0,005). Houve diferença significante de tensão na região cervical dos molares dos grupos ZirNeo e Lava (p=0,015) com maiores valores de tensão para o grupo Lava. O grupo TiNeo teve maior resistência à fratura que os demais (p=0,022). O relacionamento entre os componentes da prótese permaneceu favorável para todos os grupos. Os resultados deste trabalho permitem concluir que a prensagem da porcelana e a termociclagem mecânica não influenciou os resultados da desadaptação marginal e melhorou a desadaptação interna. O grupo usinado pelo sistema Neodent digital em zircônia teve maior concentração de tensão na região cervical podendo ter maior perda óssea nessa região. O grupo TiNeo foi o que mais resistiu à fratura. Entre fresar em zircônia pelo sistema Neodent digital ou Lava, o sistema Lava distribui melhor a tensão ao longo do implante, porém teve maiores valores de desadaptação interna. Entre fresar em titânio ou confeccionar a prótese pelo sistema convencional, melhor fresar. / Considering the growing aesthetic requirements, the development of zirconia and the increase of CAD/CAM technology, the aim of this study was to evaluate the marginal and internal fit, tensions in implants and fracture resistance after pressing porcelain and thermomechanical cycling in FPDs on implants with abutments and infrastructure in zirconia with two CAD/CAM systems (Neodent digital -Neodent and Lava - 3M ESPE) compared with the conventional method (n = 10). The marginal and internal fit was analyzed by a computerized microtomograph (microCT). Each prosthesis was scanned and the files were processed using the NRecon and CTAN software. Dataview program was used for the assessment of the measures. To carry out the thermomechanical cycling, prostheses were placed in mechanical fatigue machine for chewing and 120 N load was applied with a tip that simulates the antagonist occlusion simulating 2,000,000 cycles. During the test, the prostheses were kept in distilled water and thermocycled with temperatures between 5°-55° C. Digital image correlation analysis was performed to check the load transfer by implant-supported restoration. Five models were selected from each of the CAD/CAM systems and an antagonist and a load of 250 N was applied, with 0.1 mm/min speed using a universal testing machine. The fracture resistance was verified with force applied perpendicular to the long axis of the prosthesis, at pontic, until there were no more fracture resistance. After this test was evaluated the relationship between the components of the prosthesis in a scanning electron microscope (SEM). The statistical analysis showed significant difference in abutment-implant fit of molars between Lava and ZirNeo, Lava and control groups (p=.008). For vertical and horizontal fit there was no significant difference (p>.005) before and after pressing and thermomechanical cycling. The axial internal gap was significantly different before and after for molar ZirNeo groups (p<.001). The occlusal internal fit was significantly different to the PM of TiNeo and Control, and the molars of Lava and ZirNeo (p<.005). There were significant difference for tension in the cervical region of the molars of ZirNeo and Lava (p=.015) with higher values for the Lava group. TiNeo group had higher resistance to fracture than others (p=.022). The relationship between the prosthesis components remained positive for all groups. The results of this study showed that the pressing of porcelain and thermomechanical cycling did not influence the results of marginal gap and improved internal fit. The zirconia group machined by Neodent digital system had higher concentration of tension in the cervical and may have greater bone loss in this region. TiNeo group was the most resistant to fracture. Between the zirconia milling by Neodent digital or Lava system, the Lava system distributes better strain throughout the implant, but had greater internal fit values. Between milling titanium or fabricate the prosthesis by the conventional system, better milling.
5

Prognostics for Condition Based Maintenance of Electrical Control Units Using On-Board Sensors and Machine Learning

Fredriksson, Gabriel January 2022 (has links)
In this thesis it has been studied how operational and workshop data can be used to improve the handling of field quality (FQ) issues for electronic units. This was done by analysing how failure rates can be predicted, how failure mechanisms can be detected and how data-based lifetime models could be developed. The work has been done on an electronic control unit (ECU) that has been subject to a field quality (FQ) issue, determining thermomechanical stress on the solder joints of the BGAs (Ball Grid Array) on the PCBAs (Printed circuit board assembly) to be the main cause of failure. The project is divided into two parts. Part one, "PCBA" where a laboratory study on the effects of thermomechanical cycling on solder joints for different electrical components of the PCBAs are investigated. The second part, "ECU" is the main part of the project investigating data-driven solutions using operational and workshop history data. The results from part one show that the Weibull distribution commonly used to predict lifetimes of electrical components, work well to describe the laboratory results but also that non parametric methods such as kernel distribution can give good results. In part two when Weibull together with Gamma and Normal distributions were tested on the real ECU (electronic control unit) data, it is shown that none of them describe the data well. However, when random forest is used to develop data-based models most of the ECU lifetimes of a separate test dataset can be correctly predicted within a half a year margin. Further using random survival forest it was possible to produce a model with just 0.06 in (OOB) prediction error. This shows that machine learning methods could potentially be used in the purpose of condition based maintenance for ECUs.

Page generated in 0.1462 seconds