Strengthening T-Joints of Rectangular Hollow Steel Sections Using Through-Wall Bolts and Externally Bonded FRP Plates

Aguilera, JOSE Jr 28 September 2012 (has links)
T-joints are common in beam-column connections of steel frames, vierendeel girders and at mid-span of N-trusses. Strengthening the members of these structures increases the demand on the joints, which may require joint strengthening. This thesis examines different strengthening techniques of T-joints of RHS members. In Phase I, the effectiveness of through-wall steel bolts is examined. This is accomplished by controlling the web outward buckling of the chord under the brace axial load. The study examined the effect of the number and pattern of bolts, as well as the web height-to-wall thickness (h/t) ratio of the chord, on strengthening effectiveness. Rectangular 203x76x(3.09, 4.5, and 5.92) mm chord members were tested. The 8 mm diameter steel bolts varied from a single bolt to 15 bolts of various distributions. The joint strength increased by 3.1%, 6.2%, and 29% for chords with (h/t) of 34, 45, and 65, respectively. The number and distribution of bolts had little effect on their effectiveness. In Phase II, similar T-joint specimens were strengthened using adhesively bonded GFRP plates, 9.5 mm thick, of different configurations, and 2 mm thick high-modulus CFRP plates of equivalent stiffness. It was shown that strength gain increases significantly, from 9% to 38%, as (h/t) ratio of the HSS chord increases from 34 to 65. In thin-walled HSS (h/t = 65), retrofitting provided significant gains in strength but not in ductility. In thick-walled HSS (h/t = 34), retrofitting provided little strength gain, but enhanced ductility, especially with properly bonded plates extending on the brace. Generally, plates fractured under local bending or delaminated within plate layers while bond was fully intact. In Phase III, selected configurations of the two retrofitting methods were used in additional T-joints with chord (h/t) ratio of 65, to study their effectiveness in presence of axial compression load in the chord. Two sustained load levels were induced in the chord, representing 45% and 80% of its full axial capacity. The transverse brace load was then gradually increased to failure. The through-wall steel bolts increased the joint capacity by 13% to 25%, depending on the chord’s axial load level, while the bonded GFRP plate increased the capacity by 38 to 46%. / Thesis (Master, Civil Engineering) -- Queen's University, 2012-09-28 12:40:44.479
82

Fibre reinforced polymer (FRP) strengthened masonry arch structures

Tao, Yi January 2013 (has links)
Masonry arch bridges have played a significant role in the road and rail transportation network in the world for centuries. They are exposed to damage due to overloading and deterioration caused by environmental actions. In order to reestablish their performance and to prevent their collapse in various hazardous conditions, many of them require strengthening. Fibre reinforced polymer (FRP) systems are increasingly used for repair and strengthening of structures, with particularly widespread application to concrete structures. However, the application of FRP composites to masonry structures is less well established due to the complexity of masonry caused by the material discontinuity. FRP strengthening masonry arch bridges has been even less studied due to the additional complexity arising from the co-existence of the normal interfacial stress and the shear interfacial stress at the curved FRP-to-masonry bondline. This thesis presents an extensive study investigating the behaviour of FRP strengthened masonry bridges. The study started with a laboratory test of a two span masonry arch bridge with sand backfill. A single ring arch bridge was first tested to near failure, and then repaired by bonding FRP into their intrados and tested to failure. It was found that the FRP strengthening not only improved the loading capacity and stiffness of bridge, but also significantly restrained the opening of cracks in the masonry. Shear and peeling debonding of FRP was observed. There have been two common strategies in finite element (FE) modelling of FRP strengthened structures in meso-scale: direct model and interface model. The former is necessary when investigating the detailed bond behaviour but challenges remain due to the difficulties in concrete modelling. A new concrete damage model based on the plastic degradation theory has been developed in this study to study the bond behaviour of FRP strengthened concrete structure. This robust model can successfully capture this bond behaviour and simulate the entire debonding process. A numerical study of masonry arch bridges including the backfill was conducted to study the behaviour of masonry arch bridge. A total of four modelling strategies were examined and compared. Although they all can successfully predict the behaviour of arch, a detailed solid model newly developed in this study is more suitable for modelling both plain masonry and FRP strengthened structures. Finally, a numerical study of bond behaviour and structural response of FRP strengthened masonry arch structures with sand backfill was conducted. In addition to the masonry and backfill, the mixed mode interfacial behaviour was modelled by the aforementioned interface model strategy and investigated in detail to achieve a deeper understanding of the behaviour of FRP strengthened masonry arch structures. The results are in close agreement with test results, and highlight the influence of the key parameters in the structural response to failure and revealed the mechanisms on how the load is transmitted through this complex multi-component structural system.
83

Experimental and analytical analysis of the stress-strain diagram of FRP-confined concrete with different loading rates

Sutherland, Brandy January 1900 (has links)
Master of Science / Department of Civil Engineering / Asadollah Esmaeily / The accuracy and applicability of the existing stress-strain models for concrete confined by Carbon Fiber Reinforced Polymer (CFRP) were analytically and experimentally explored. This investigation includes major parameters affecting the stress-strain response of confined concrete, including the loading pattern and protocol. It has been observed and reported that the experimentally recorded stress-strain relationship of the same specimen will be different if the loading protocol of the test is switched from displacement control to load control. In the experimental phase of this study, four standard 6" by 12" concrete cylinders were constructed using the same concrete batch for consistency. Three two-inch strain gauges were affixed equally spaced at mid-height on the surface of the specimen in the longitudinal direction, and two two-inch strain gauges were applied in the lateral direction at mid-height opposite each other. CFRP was then impregnated with a two-part epoxy and applied externally in two continuous layers, with an overlap. During the first phase of the experimental program, the tests were conducted with a constant load rate or with a constant displacement rate. The data was collected from externally mounted strain gauges and potentiometers positioned on the opposite sides of the cylinder in the longitudinal direction. Since the capacity of the existing actuator in the structural lab was less than the required failure level of the specimens, a nutcracker-like device was constructed to increase the mechanical advantage of the test frame in the second phase of the experimental program. In this phase, all tests were conducted in displacement control. Various models were selected to be studied from a large number of existing models that propose to determine the stress-strain relationship of concrete. Analytical predictions of the models were compared against the experimental data. Results show that some of the models provide a reasonable prediction of the real performance of the specimen. However, in general, predictions are different from the real performance for most models.
84

Development of Surface Flaw Thresholds for Pre-Cured Fiber Reinforced Polymer and Groove Size Tolerance for Near Surface Mounted Fiber Reinforced Polymer Retrofit Systems

Kalayci, Ahmet Serhat 16 July 2008 (has links)
Since the introduction of fiber reinforced polymers (FRP) for the repair and retrofit of concrete structures in the 1980’s, considerable research has been devoted to the feasibility of their application and predictive modeling of their performance. However, the effects of flaws present in the constitutive components and the practices in substrate preparation and treatment have not yet been thoroughly studied. This research aims at investigating the effect of surface preparation and treatment for the pre-cured FRP systems and the groove size tolerance for near surface mounted (NSM) FRP systems; and to set thresholds for guaranteed system performance. The research included both analytical and experimental components. The experimental program for the pre-cured FRP systems consisted of a total of twenty-four (24) reinforced concrete (RC) T-beams with various surface preparation parameters and surface flaws, including roughness, flatness, voids and cracks (cuts). For the NSM FRP systems, a total of twelve (12) additional RC T-beams were tested with different grooves sizes for FRP bars and strips. The analytical program included developing an elaborate nonlinear finite element model using the general purpose software ANSYS. The model was subsequently used to extend the experimental range of parameters for surface flatness in pre-cured FRP systems, and for groove size study in the NSM FRP systems. Test results, confirmed by further analyses, indicated that contrary to the general belief in the industry, the impact of surface roughness on the global performance of pre-cured FRP systems was negligible. The study also verified that threshold limits set for wet lay-up FRP systems can be extended to pre-cured systems. The study showed that larger surface voids and cracks (cuts) can adversely impact both the strength and ductility of pre-cured FRP systems. On the other hand, frequency (or spacing) of surface cracks (cuts) may only affect system ductility rather than its strength. Finally, within the range studied, groove size tolerance of +1/8 in. does not appear to have an adverse effect on the performance of NSM FRP systems.
85

Response of Reinforced Concrete Columns Subjected to Impact Loading

Imbeau, Paul January 2012 (has links)
Reinforced Concrete (RC) bridge piers, RC columns along exterior of buildings or those located in parking garages are designed to support large compressive axial loads but are vulnerable to transverse out-of-plane loadings, such as those arising from impacts or explosions. To address a lack of understanding regarding blast and impact response of RC members and the need for retrofit techniques to address deficiencies in existing structures, a multi-disciplinary team including various institutes of the National Research Council and the University of Ottawa has initiated work towards developing a fibre reinforced polymer composite protection system for RC columns subjected to extreme shocks. This thesis will focus on the impact program of the aforementioned project. An extensive literature review was conducted to gain a better understanding of: impact loading and associated dynamic effects; experimental testing of RC members subjected to impact; experimental testing of axially loaded members; and retrofit methods for the protection of RC under impact loading. Five half-scale RC columns were constructed and tested using a drop-weight impact machine and two additional specimens were tested under static loading. Deflections, strain distributions within the columns, impact loads and reaction loads were measured during the testing of the built RC members. Comparisons of experimental datum were established between members with differing levels of axial load and between a retrofitted and a non-retrofitted member. Single-degree-of-freedom analysis was used to obtain the predicted response of certain columns under impact loading allowing for comparisons with experimental data.
86

Three dimensional analysis of fibre reinforced polymer laminated composites

Haji Kamis, Haji Elmi Bin January 2012 (has links)
The thesis presents the structural behaviour of fibre reinforced polymer (FRP) laminated composites based on 3D elasticity formulation and finite element modeling using Abaqus. This investigation into the performance of the laminate included subjecting it to various parameters i.e. different boundary conditions, material properties and loading conditions to examine the structural responses of deformation and stress. Both analytical and numerical investigations were performed to determine the stress and displacement distributions at any point of the laminates. Other investigative work undertaken in this study includes the numerical analysis of the effect of flexural deformation of the FRP strengthened RC slab. The formulation of 3D elasticity and enforced boundary conditions were applied to establish the state equation of the laminated composites. Transfer matrix and recursive solutions were then used to produce analytical solutions which satisfied all the boundary conditions throughout all the layers of the composites. These analytical solutions were then compared with numerical analysis through one of the commercial finite element analysis programs, Abaqus. Out of wide variety of element types available in the Abaqus element library, shells and solids elements are chosen to model the composites. From these FEM results, comparison can be made to the solution obtained from the analytical. The novel work and results presented in this thesis are the analysis of fully clamped laminated composite plates. The breakthrough results of fully clamped laminated composite plate can be used as a benchmark for further investigation. These analytical solutions were verified with FEM solutions which showed that only the solid element (C3D20) exhibited close results to the exact solutions. However, FEM gave poor results on the transverse shear stresses particularly at the boundary edges. As an application of the work above, it is noticed that the FEM results for the FRP strengthened RC slab, agreed well with the experimental work conducted in the laboratory. The flexural capacity of the RC slab showed significant increase, both at service and ultimate limit states, after FRP sheets were applied at the bottom surface of the slab. Given the established and developed programming codes, exact solutions of deflection and stresses can be determined for any reduced material properties, boundary and loading conditions, using Mathematica.
87

Studium vlastností ohýbaných FRP výztuží / Study of properties of bent FRP reinforcement

Lipoldová, Marie January 2021 (has links)
The diploma thesis deals with the study of bent FRP reinforcements with the main focus on the methods of production of bent FRP reinforcement, examples of their application in structures. The work also mentions the effects of aggressive environments on the durability of FRP. In the practical part, a search of the possibilities of testing the properties of bent FRP reinforcement. Subsequently, an experiment is designed and performed to monitor changes in the properties of straight and bent FRP reinforcement exposed to the alkaline environment and water at 20 °C and 40 °C. Finally, the evaluation of changes in mechanical properties and observation of reinforcements using optical and scanning electron microscopy is performed.
88

Bending Behavior of Concrete Beams with Fiber/Epoxy Composite Rebar

Rice, Kolten Dewayne 12 December 2019 (has links)
This research explores the use of carbon/epoxy and fiberglass/epoxy fiber-reinforced polymer (FRP) composite rebar manufactured on a three-dimensional braiding machine for use as reinforcement in concrete beams under four-point bending loads. Multiple tows of prepreg composite fibers were pulled to form a unidirectional core. The core was consolidated with spirally wound Kevlar fibers which were designed to also act as ribs to increase pullout strength. The rebar was cured at 121â—¦C (250â—¦F) in an inline oven while keeping tension on the fibers. Five configurations of reinforcing bars were used in this study as reinforcement in concrete beam specimens: carbon/epoxy rebar and fiberglass/epoxy rebar were manufactured on the three-dimensional braiding machine and cured in an inline oven while still under tension immediately after production; carbon/epoxy rebar was manufactured by IsoTruss industries on the three-dimensional braiding machine and was rolled and stored before curing; fiberglass/epoxy rebar was purchased from American Fiberglass; conventional No. 4 steel rebar was also purchased. All bars were embedded in 152 cm (60 in) long, 11 cm (4.5 in) wide, and 15 cm (6.0 in) tall concrete beams. Beams were tested under four-point bending loads after which three 30 cm (12 in) specimens were taken from the ends of each configuration to be tested under axial compression loads in order to investigate the effects of the concrete voids on the concrete strength. Concrete beams reinforced with BYU glass/epoxy rebar manufactured on the three-dimensional braiding machine exhibited 5% greater compression bending stress and 11% greater tension bending stress than concrete beams reinforced with industry manufactured glass/epoxy rebar. Concrete beams reinforced with BYU carbon/epoxy rebar manufactured on the three-dimensional braiding machine exhibited 18% lower compression bending stress and 64% lower tension bending stress than concrete beams reinforced with industry manufactured carbon/epoxy rebar. BYU glass/epoxy rebar has a 3% greater stiffness and 1% greater displacement than industry manufactured glass/epoxy rebar and BYU carbon/epoxy rebar has a 40% greater bending stiffness and 19% lower displacement than industry carbon/epoxy rebar. BYU carbon/epoxy rebar has 49% lower compression bending stress, 1% lower tension bending stress, 28% lower displacement, and a 68% greater bending stiffness than BYU glass/epoxy rebar. BYU glass/epoxy rebar has 38% greater compression bending stress, 30% lower tension bending stress, 26% greater center displacement, and a 105% lower bending stiffness than conventional steel. BYU carbon/epoxy rebar has 8% lower compression bending stress, 31% lower tension bending stress, and 22% lower bending stiffness than steel. The deflections of steel reinforced concrete and BYU carbon/epoxy reinforced concrete are comparable with steel rebar displaying a 1% greater center displacement than BYU carbon/epoxy rebar.
89

Blast Performance of Reinforced Concrete Columns Protected by FRP Laminates

Kadhom, Bessam January 2016 (has links)
Recent terrorist attacks on critical infrastructures using car bombs have heightened awareness on the needs for blast resistance of structures. Blast design of civilian buildings has not been a common practice in structural design. For this reason, there is now an urgent need to mitigate the potentially devastating effects of blast shock waves on existing structures. The current research project, the results of which are reported in this dissertation, aims to expand knowledge on blast resistance of reinforced concrete building columns, while developing a technology and design procedure for protecting critical buildings columns against the damaging effects of impulsive blast loads through the use of externally applied fibre-reinforced polymer (FRP) jackets of different material architecture. The research project has a significant experimental component, with analytical verifications. A total of thirty two reinforced concrete columns were experimentally investigated under the effects of simulated blast loads using the University of Ottawa Shock Tube. Column dimensions were 150 mm x 150 mm in cross section and 2438 mm in length. Each concrete column was reinforced longitudinally with four 10M rebars which were tied laterally with 6.3 mm closed steel hoops, spaced at 37.5 mm and 100 mm c/c, representing seismic and non-seismic column details, respectively. The experimental research had two phases. Phase-I (sub-study) included blast tests of eight as-built, seismically detailed columns. The behaviour of these columns was explored under single and multiple blast shots, with and without the application of pre-blast axial loads. Phase-II (main-study) included column tests of different carbon FRP (CFRP) designs to investigate the significance of the use of different CFRP column jacket designs on dynamic response of twenty four seismic and non-seismic RC columns. Analytical investigation was conducted to assess and verify the significance of experimentally investigated parameters on column response. These included the use of Single-Degree-of-Freedom (SDOF) dynamic inelastic analysis, generation of dynamic resistance functions, the effects of variable axial loads, different plastic hinge lengths and the influence of secondary moments (P- moments) on column behaviour. The results indicate that the loading history has effects on column response, with multiple shots reducing column stiffness, and affecting dynamic response of columns relative to single blast shots of equivalent magnitude. The effect of concrete strength within the normal-strength concrete range is to increase strength and decrease deformations. Columns with CFRP jackets have considerable improvements in column deformability, with additional increases in column strength. The CFRP laminate design influences performance, with jackets having fibres in ±45o orientation especially improving column ductility and increasing plastic hinge lengths, thereby permitting redistribution of stresses and dissipating blast energy. Axial gravity loads vary during blast loads and can affect column strength. It was shown that SDOF dynamic inelastic analysis does capture key structural performance parameters in blast analysis. The consideration of experimentally observed parameters in column analysis; including the influence of CFRP design and associated change in plastic hinge length, variable axial load during response, and secondary moment (P- moments) result in significant improvements in the accuracy of blast analysis. The experimental results and the suggested improvements to the SDOF analysis technique can be used to implement a performance-based design approach recommended as part of the current research project for design of CFRP protection systems for concrete columns.This research project was conducted jointly by the National Research Council Canada (NRC) and the University of Ottawa.
90

Zesilování železobetonových sloupů ovinutím FRP tkaninou / Strengthening reinforced concrete column confined by FRP fabric

Kostiha, Vojtěch January 2018 (has links)
The doctoral thesis deals with the strengthening of reinforced concrete columns by FRP fabric wrapping. Its aim is to describe the principles of confinement based on the analytical study, numerical simulations and the results of the experimental program. The description of the confinement philosophy is made with respect to the type of FRP material used. It was therefore possible to present a design process of confinement, which accurately predicts the behaviour of the confined columns. At the same time, some effects limiting the effect of confinement (e.g. the method of wrapping, the number of FRP fabric layers, the slenderness of the element, etc.) are included in the design. The dissertation also presents basic information about FRP material and its properties and gives an overview of design approaches of the FRP confined columns. The dissertation also pointing out the shortcomings of the design code ČSN EN 1992-1-1. The stated example highlights the significant variation in properties of confined concrete determined by selected approaches. This variation of properties complicates the design of this strengthening method. The experimental program was used to verify the basic principles of confinement and, through high columns, allowed a description of the behaviour in almost the whole range of interaction diagram. The conclusions of the work provide information on possible future research direction.