• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • Tagged with
  • 24
  • 9
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Ação do vento em cobertura de madeira roliça para galpões de fertilizantes

Pansiera, Daví Blas [UNESP] 21 December 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-21Bitstream added on 2014-06-13T20:32:48Z : No. of bitstreams: 1 pansiera_db_me_ilha.pdf: 3062626 bytes, checksum: adfa69acace77a9c80daa21019f26f63 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O Brasil é um país de forte vocação agrícola, que necessita lugares adequados para armazenagem de matérias subsidiárias, como por exemplo, óleos, detergentes, tintas, fertilizantes entre outros; de armazenagem de ferramentas, instrumentos, dispositivos, madeiras. As maiorias dos galpões são feitos de concreto, aço, madeira, porém existem aqueles chamados mistos. Com isso o projeto busca atender as necessidades de empresas que buscam poder armazenar seus fertilizantes em galpões feitos com madeira de reflorestamento, que é o Eucalipto Citriodora. A técnica construtiva aplicada pretende ter mais rapidez para que a estrutura fique pronta para o uso, além de economizar em mão-de-obra, materiais mais baratos e por fim, contribuindo para o uso sustentável da madeira no Brasil e procurando inspirar que não só aqui no Brasil e como vários lugares do mundo que é necessário que todos se conscientizem e preservem o “verde” do planeta. Será feito todo o estudo necessário para que este tipo de modelo, cujas dimensões para analise são de 5, 6 e 7,5 metros de comprimento, por 30 metros de largura e 15 metros de altura esteja de acordo com as normas. A estrutura terá uma série de pórticos, utilizando-se duas peças de madeira roliças para cada um deles e travadas em sua parte mais delgada através de uma ligação em forma de capuz metálico, formando um ângulo de 90o entre as peças. Para travar os 2 pórticos é utilizada uma peça roliça de madeira que usará conectores metálicos para fazer a ligação e estará posicionado a três quartos da altura do pórtico. Na base do poste há um tensionamento diminuindo o vão do pórtico de 31,5m para 30,0 m utilizando-se um cabo de aço e retirando-o quando colocado na base da fundação. Os cálculos teóricos da estrutura foram realizados seguindo as NBR 7190:1997 e NBR 6123:1988; e através de... / Brazil is a country of strong agricultural vocation, which requires adequate sites for storage of subsidiary materials such as oils, detergents, paints, fertilizers, among others, storage of tools, instruments, appliances, wood. The majority of houses are made of concrete, steel, wood, however there are those called mixed. Thus the project aims to meet the needs of companies seeking to be able to store their fertilizers in sheds made of wood from reforestation, which is lemon eucalyptus. The construction technique used aims to have more speed for the structure to be ready for use, and saves on manpower, materials cheaper and ultimately contributing to the sustainable use of wood in Brazil and looking to inspire not only here in Brazil and how many places around the world that all must be aware and preserve the green the planet. It will be done all the studies required for this type of model to analyze the dimensions are 5, 6 and 7.5 meters long by 30 meters wide and 15 meters in height is consistent with the standards. The structure will have a series of frames, using two pieces of wood for each of them plump and locked in its thinnest part through a link-shaped metal hood, forming an angle of 90 ° between the parts. To lock the two frames is used a plump piece of wood that will use metal connectors to connect and be positioned at three-quarters of the height of the portico. At the base of the pole there is a tension reducing the span of the portico of 31.5 m to 30.0 m using a rope and pulling it while stationed at the foundation. Theoretical calculations of the structure were carried out using the NBR NBR 7190:1997 and 6123:1988, and by a numerical model developed in SAP2000 software, you can examine its behavior when subjected to proper weight and due to wind action. Concluding that it is not feasible to apply the tension and inclination of 30 ° is more appropriate, since the maximum span between frames is 6 feet.
22

Conforto térmico nos edifícios das indústrias de calçados de Jaú / Thermal comfort in footwear industry from Jaú

Prado, Monica Faria de Almeida 25 April 2012 (has links)
Este trabalho aborda o desempenho térmico obtido em edifícios industriais do setor calçadista, perante a importância em obter condições ambientais favoráveis à execução das atividades através de uma arquitetura adequada ao contexto climático. Assim, o objetivo nesta pesquisa é avaliar as condições de conforto térmico oferecidas pelos edifícios das indústrias calçadistas do município de Jaú, um importante pólo industrial do setor no interior de São Paulo. Caracterizam-se as tipologias construtivas dos edifícios quanto à geometria, materiais e sistema de ventilação. As estratégias passivas para obtenção de conforto térmico nos galpões fabris são identificadas e avaliadas utilizando as recomendações presentes na NBR 15220. Para avaliar as condições de conforto térmico, foram medidas as variáveis ambientais, sendo que a temperatura foi analisada sob condições de aceitabilidade térmica, conforme estabelecido pela ASHRAE 55-2010. Para estimar a sensação térmica dos usuários, são utilizados os índices PMV e PPD. Também foi aplicado um questionário para verificar o nível de satisfação dos funcionários com o ambiente de trabalho. Os resultados apontam que a maioria dos edifícios apresenta uma tipologia semelhante, com geometria retangular e ventilação realizada através de esquadrias nas fachadas. A ausência de diversas estratégias passivas resulta em um edifício com baixa inércia térmica e vulnerável às condições climáticas externas, sendo que em períodos quentes a temperatura interna foi superior a 30ºC, e em períodos frios inferior a 15ºC. A sensação térmica dos usuários na maior parte do período do expediente corresponde ao desconforto térmico para o calor, principalmente no período vespertino, sendo que a porcentagem de insatisfeitos ultrapassa 80%. Deste modo, há necessidade de otimizar a adoção de estratégias passivas, para proporcionar melhores condições térmicas de trabalho. Para isto, são indicadas soluções simples, que propiciam melhorias ao desempenho térmico dos edifícios, exemplificando: o uso de sistemas que possibilitem o resfriamento evaporativo e ampliação das áreas de aberturas destinadas à ventilação do edifício. / This paper discusses the thermal performance obtained in industrial buildings in the footwear sector, given the importance of obtaining favorable environmental conditions for the execution of activities through an architecture suited to the climate context. Thus, the objective of this research is to evaluate the thermal comfort conditions provided by the buildings of the footwear industries of Jaú city, an important industrial pole. It is characterized the typologies of building\'s construction regarding its geometry, materials and ventilation system. The passive strategies for achieving thermal comfort in the factory sheds are identified and evaluated using the recommendations present in the NBR 15220. To evaluate the thermal comfort conditions it was measured the environmental variables, and the temperature was examined under conditions of thermal acceptability, as established by ASHRAE 55-2010. In order to estimate the thermal sensation of the users, the PMV and PPD indices were used. Also, a questionnaire was applied in order to check the level of employee satisfaction with the working environment. The results show that most of the buildings presents a typology similar with a rectangular geometry and ventilation obtained through frames at the facades. The absence of different passive strategies results in a building with a low thermal inertia and vulnerable to the external weather conditions, and in hot periods, the internal temperature was above 30°C, and during colder periods it was lower than 15°C. The thermal sensation of users in most of the period of the working shift matches the thermal discomfort to the heat, especially in the afternoon, and the percentage of discontentment exceeds 80%. This way, there is a need to optimize the adoption of passive strategies, to provide better thermal conditions of work. For this purpose, simple solutions that provide improvements to the thermal performance of buildings are given, examples: the use of systems which allows evaporative cooling and expansion of openings areas for the ventilation of the building.
23

Pilares mistos de aço e concreto parcialmente revestidos: comportamento isolado, inserção em galpões industriais e comparativos com pilares de sistemas estruturais usuais

Serafim, Jorge Augusto 16 May 2013 (has links)
Made available in DSpace on 2016-06-02T20:09:19Z (GMT). No. of bitstreams: 1 5850.pdf: 3492179 bytes, checksum: a8bf8363cbcbb501bfa5251bc969c178 (MD5) Previous issue date: 2013-05-16 / Despite the great use in most developed countries, the composite structures have been little exploited in Brazil, including rare records the use of composite columns of steel and concrete partially coated in industrial sheds. The low-use leaves the impression of this being a structural solution viable. The aim of this work is to insert the composite columns of steel and concrete partially coated alternatively to the pillars of steel and precast, solutions commonly used in the composition of the structural system of industrial sheds. The development work was done to study the behavior of the isolated element and sizing criteria applicable, analysis of the structural design of systems where it can be employed and the phases of project highlighting, still, some steps involved in constructive phase of the industrial sheds. We analyzed the elements of 108 sheds with variation in the span between 20 to 50 m and height of 8 to 12 m. the porticos were designed considering coverage using steel beams with profile type I and type I section steel pillars, pillars of precast concrete with rectangular section, composite columns of steel and concrete partially coated consisting of metallic profile type I with filling of concrete between the tables. The porticoes were analyzed in 2nd order and scaled according to the specific Brazilian standards by comparing the results obtained between structural systems. Costs despite the difficulties have been raised for the central region of the State of São Paulo, where, after the composition were made comparisons between the solutions. The results obtained can realize that the use of composite columns of steel and concrete partially coated are perfectly viable with visa point economic values quite surprising, for the fact of being a solution less maid. The use of composite columns of steel and concrete partially coated is obviously viable as an alternative to the usual structural systems used in industrial sheds, comes in to advance contribution of Civil construction in General. / Apesar da grande utilização em países mais desenvolvidos, as estruturas mistas têm sido pouco exploradas no Brasil, inclusive com raros registros da utilização de pilar parcialmente revestido em galpões industriais. A pouca utilização deixa a impressão de esta não ser uma solução estrutural viável. O objetivo deste trabalho é inserir o pilar misto parcialmente revestido como alternativa aos pilares de aço e pré-moldados de concreto, soluções comumente empregados na composição do sistema estrutural de galpões industriais. Para o desenvolvimento do trabalho foi feito o estudo do comportamento do elemento isolado e dos critérios de dimensionamento aplicáveis, a análise da concepção estrutural dos sistemas onde possa ser empregado e das fases de projeto destacando, ainda, algumas etapas envolvidas na fase construtiva dos galpões. Foram analisados os elementos de 108 pórticos de galpão com variação do vão de 20 a 50 m e da altura de 8 a 12 m. Os pórticos foram projetados considerando cobertura utilizando-se vigas metálicas com perfil tipo I e, pilares metálicos de seção tipo I, pilares de concreto pré fabricado de seção retangular e, pilar misto parcialmente revestido constituído de perfil metálico tipo I com preenchimento de concreto entre as mesas. Os pórticos foram analisados em 2ª ordem e dimensionados de acordo com as normas brasileiras especificas comparando os resultados obtidos entre sistemas estruturais. Os custos apesar das dificuldades foram levantados para a região central do estado de São Paulo, onde, após a composição foram feitas as comparações entre as soluções. Pelos resultados obtidos pode-se perceber que a utilização dos pilares mistos de aço e concreto são perfeitamente viáveis com valores do ponto de visto econômico bastante surpreendentes pelo fato de ser uma solução pouco empregada. A utilização de pilares mistos de aço e concreto parcialmente revestidos é evidentemente viável como alternativa aos sistemas estruturais usuais utilizados em galpões industriais, vem contribuir em muito para o avanço da Construção Civil em geral.
24

Conforto térmico nos edifícios das indústrias de calçados de Jaú / Thermal comfort in footwear industry from Jaú

Monica Faria de Almeida Prado 25 April 2012 (has links)
Este trabalho aborda o desempenho térmico obtido em edifícios industriais do setor calçadista, perante a importância em obter condições ambientais favoráveis à execução das atividades através de uma arquitetura adequada ao contexto climático. Assim, o objetivo nesta pesquisa é avaliar as condições de conforto térmico oferecidas pelos edifícios das indústrias calçadistas do município de Jaú, um importante pólo industrial do setor no interior de São Paulo. Caracterizam-se as tipologias construtivas dos edifícios quanto à geometria, materiais e sistema de ventilação. As estratégias passivas para obtenção de conforto térmico nos galpões fabris são identificadas e avaliadas utilizando as recomendações presentes na NBR 15220. Para avaliar as condições de conforto térmico, foram medidas as variáveis ambientais, sendo que a temperatura foi analisada sob condições de aceitabilidade térmica, conforme estabelecido pela ASHRAE 55-2010. Para estimar a sensação térmica dos usuários, são utilizados os índices PMV e PPD. Também foi aplicado um questionário para verificar o nível de satisfação dos funcionários com o ambiente de trabalho. Os resultados apontam que a maioria dos edifícios apresenta uma tipologia semelhante, com geometria retangular e ventilação realizada através de esquadrias nas fachadas. A ausência de diversas estratégias passivas resulta em um edifício com baixa inércia térmica e vulnerável às condições climáticas externas, sendo que em períodos quentes a temperatura interna foi superior a 30ºC, e em períodos frios inferior a 15ºC. A sensação térmica dos usuários na maior parte do período do expediente corresponde ao desconforto térmico para o calor, principalmente no período vespertino, sendo que a porcentagem de insatisfeitos ultrapassa 80%. Deste modo, há necessidade de otimizar a adoção de estratégias passivas, para proporcionar melhores condições térmicas de trabalho. Para isto, são indicadas soluções simples, que propiciam melhorias ao desempenho térmico dos edifícios, exemplificando: o uso de sistemas que possibilitem o resfriamento evaporativo e ampliação das áreas de aberturas destinadas à ventilação do edifício. / This paper discusses the thermal performance obtained in industrial buildings in the footwear sector, given the importance of obtaining favorable environmental conditions for the execution of activities through an architecture suited to the climate context. Thus, the objective of this research is to evaluate the thermal comfort conditions provided by the buildings of the footwear industries of Jaú city, an important industrial pole. It is characterized the typologies of building\'s construction regarding its geometry, materials and ventilation system. The passive strategies for achieving thermal comfort in the factory sheds are identified and evaluated using the recommendations present in the NBR 15220. To evaluate the thermal comfort conditions it was measured the environmental variables, and the temperature was examined under conditions of thermal acceptability, as established by ASHRAE 55-2010. In order to estimate the thermal sensation of the users, the PMV and PPD indices were used. Also, a questionnaire was applied in order to check the level of employee satisfaction with the working environment. The results show that most of the buildings presents a typology similar with a rectangular geometry and ventilation obtained through frames at the facades. The absence of different passive strategies results in a building with a low thermal inertia and vulnerable to the external weather conditions, and in hot periods, the internal temperature was above 30°C, and during colder periods it was lower than 15°C. The thermal sensation of users in most of the period of the working shift matches the thermal discomfort to the heat, especially in the afternoon, and the percentage of discontentment exceeds 80%. This way, there is a need to optimize the adoption of passive strategies, to provide better thermal conditions of work. For this purpose, simple solutions that provide improvements to the thermal performance of buildings are given, examples: the use of systems which allows evaporative cooling and expansion of openings areas for the ventilation of the building.

Page generated in 0.0195 seconds