• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolupament de mètodes de preconcentració emprant membranes líquides suportades i extracció en fase sòlida per a la determinació de l'herbicida glifosat i el seu metabòlit AMPA en aigües naturals

Rios Losada, Carolina 16 April 2004 (has links)
El glifosat, N-(fosfonometil) glicina, és un dels herbicides més utilitzats arreu del món a causa de la seva baixa toxicitat i al seu ampli espectre d'aplicació. A conseqüència del gran ús que se'n fa, és necessari monitoritzar aquest compost i el seu principal metabòlit, l'àcid aminometilfosfònic (AMPA), en el medi ambient. S'han descrit diversos mètodes instrumentals basats en cromatografia de gasos (GC) i de líquids (HPLC), sent aquesta darrera l'opció més favorable a causa del caràcter polar dels anàlits. Per assolir nivells de concentració baixos cal, però, la preconcentració dels anàlits.En aquest treball s'estudien diferents alternatives amb aquest objectiu. S'ha avaluat la tècnica de membrana líquida suportada (SLM) on la membrana consisteix en una dissolució orgànica, que conté un transportador (en el nostre cas, un bescanviador d'anions comercial, Aliquat 336), que impregna un suport polimèric microporós que se situa entre dues solucions aquoses: la de càrrega, que conté els anàlits inicialment, i la receptora, on es retenen els anàlits després del seu transport a través de la membrana. Les condicions d'extracció més adequades s'obtenen treballant en medi bàsic amb NaOH on els anàlits estan en forma aniònica i les majors recuperacions s'obtenen amb HCl 0,1 M o NaCl 0,5 M, la qual cosa indica que l'ió clorur és la força impulsora del transport.Un cop dissenyat el sistema, es duen a terme experiments de preconcentració amb dues geometries diferents: un sistema de membrana laminar (LSLM) on recircula la fase receptora i un sistema de fibra buida (HFSLM). Els millors resultats s'obtenen amb el mòdul de fibra buida, amb factors de concentració de 25 i 3 per a glifosat i AMPA, respectivament, fent recircular durant 24 hores 100 ml de solució de càrrega i 4 ml de solució receptora. També s'aplica una tècnica més selectiva, la cromatografia d'afinitat amb ió metàl·lic immobilitzat (IMAC), basada en la interacció entre els anàlits i un metall immobilitzat en una resina a través d'un grup funcional d'aquesta. En aquest estudi s'immobilitza pal·ladi al grup funcional 8-hidroxiquinoleïna de la resina amb matriu acrílica Spheron Oxine 1000 i s'avalua per a l'extracció i preconcentració de glifosat i AMPA. Per a ambdós anàlits l'adsorció és del 100 % i les recuperacions són superiors al 80 % i al 60 % per a glifosat i AMPA, respectivament, utilitzant HCl 0,1 M + NaCl 1 M com a eluent. Aquests resultats es comparen amb els obtinguts amb dues resines més, també carregades amb pal·ladi: Iontosorb Oxin 100, que té el mateix grup funcional però matriu de cel·lulosa, i Spheron Thiol 1000, on el grup funcional és un tiol i la matriu també és acrílica. Per al glifosat els resultats són similars amb totes les resines, però per a l'AMPA la resina Spheron Thiol és la única que proporciona recuperacions superiors al 93 %.Finalment, una altra opció estudiada és l'acoblament de dues columnes de cromatografia líquida (LC-LC). En l'estudi l'objectiu és millorar el mètode existent per a glifosat i AMPA en aigües naturals on el LOD era de 0,25 ug/l. El mètode consisteix en la derivatització precolumna amb el reactiu fluorescent FMOC i l'anàlisi amb l'acoblament LC-LC-fluorescència. Variant lleugerament les condicions de derivatització s'aconsegueix quantificar 0,1 ug/l de glifosat i AMPA. Es fortifiquen aigües naturals amb 0,1, 1 i 10 ug/l dels anàlits per validar el mètode. S'obtenen recuperacions d'entre el 85 % i el 100 %, amb desviacions estàndard relatives inferiors al 8 %. Aplicant una tècnica de preconcentració prèvia a la derivatització i anàlisi utilitzant una resina de bescanvi aniònic, Amberlite IRA-900, es millora la sensibilitat del mètode i s'assoleix un LOD per al glifosat de 0,02 ug/l. / Glyphosate, N-(phosphonomethyl)glycine, is one of the most widely used herbicides in the world due to its low mammal toxicity. Therefore, there is a great interest in the monitoring of this compound and its major metabolite aminomethylphosphonic acid (AMPA), in environmental matrices. A great variety of methods based on gas chromatography (GC) and liquid chromatography (HPLC) have been applied for their determination. HPLC is the most popular option due to the polar nature of both compounds. However, the analysis of these compounds at residue levels requires the use of preconcentration techniques.In this work we have studied different alternatives to this aim. We have evaluated the supported liquid membrane (SLM) technique where the membrane consists of an organic solution, which contains the carrier (in this case a commercial anion exchanger extractant, Aliquat 336), that impregnates a microporous polymeric support placed between two aqueous solutions: the feed solution, which initially contains the analytes, and the stripping solution, where the analytes are retained after their transport through the membrane. The best conditions were achieved with NaOH as feed solution, where the analytes are present in their anionic form and 0.1 M HCl or 0.5 M NaCl as stripping solutions indicating that the chloride ion is the responsible for the transport.Under these chemical conditions some preconcentration experiments were run using two different geometries of the membrane: a laminar membrane system (LSLM) where the stripping solution can be recirculated and a hollow fiber liquid membrane (HFSLM). The best results were obtained for the liquid membrane system in HF configuration, with concentration factors of 25 and 3 for glyphosate and AMPA, respectively, after recirculation during 24 hours of 100 ml of feed solution and 4 ml of stripping solution.A more selective technique is also studied, immobilised metal ion affinity chromatography (IMAC), which is based on the interaction between the analytes and a metal immobilised in a resin through a functional group. In this work we have immobilised palladium through the chelating group 8-hydroxyquinoline of the acrylic resin Spheron Oxine and it has been evaluated for the preconcentration of glyphosate and AMPA. 100 % adsorption has been obtained for both analytes and the recoveries are higher than 80 % and 60 % for glyphosate and AMPA, respectively, using 0.1 M HCl + 1 M NaCl as eluent. These results are compared with the results obtained working with two different resins also charged with palladium: Iontosorb Oxin, which has the same functional group but cellulose matrix, and Spheron Thiol, which a thiol functional group and acrylic matrix. The results for glyphosate are similar with all the resins tested, but for AMPA the best results are obtained with Spheron Thiol with recoveries higher than 93 %.Finally, another option studied is the coupling of two liquid chromatographic columns (LC-LC). In this work the objective is to improve the existing method for the analysis of glyphosate and AMPA in natural waters which had a LOD of 0.25 mg/l. The method consists of the pre-column derivatization with the fluorescent reagent FMOC and the analysis by LC-LC-fluorescence detection. The derivatization step has been slightly modified with the aim of decreasing the limits of quantification of glyphosate and AMPA down to 0.1 mg/l. Different water samples spiked at three concentration levels (0.1, 1, 10 mg/l) were analysed by the improved method yielding recoveries between 85-100 % with relative standard deviations lower than 8 %.Additionally, the potential of an anion-exchange resin, Amberlite IRA-900, for preconcentration of glyphosate, previously to the derivatization step, has been investigated. In this way the LOD of the parent compound has been lowered to 0.02 mg/l.
2

Desenvolupament de metodologia analítica per a la determinació de glifosat i adjuvants

Corbera Mas, Marta 15 February 2008 (has links)
El glifosat és un herbicida no selectiu àmpliament utilitzat en cultius agrícoles i zones no agrícoles que requereixen un control de la vegetació. Tot i la baixa toxicitat del glifosat en si mateix, la seva aplicació es realitza emprant formulacions comercials que contenen substàncies auxiliars que milloren l'eficàcia de l'herbicida, però modifiquen la toxicitat del producte final.Aquest treball s'ha centrat en la determinació de components de formulacions comercials d'herbicides i el seu comportament en el sòl. La primera part del treball s'ha dedicat al desenvolupament de mètodes d'anàlisi per a la determinació de glifosat i el seu principal metabòlit, AMPA, en matrius aquoses i sòls. A continuació s'ha desenvolupat un mètode d'anàlisi per les substàncies auxiliars addicionades freqüentment en les formulacions comercials, tensioactius no iònics. Finalment s'ha estudiat la mobilitat de l'herbicida en sòls de la zona mediterrània, incidint en els processos d'adsorció i degradació. També s'ha comparat el comportament de diversos herbicides comercials que contenen glifosat. / Glyphosate is a non-selective broad-spectrum herbicide widely used both in agriculture and in the control of vegetation in nonagricultural land. The toxicity of pure glyphosate is low but commercial formulations usually contain auxiliary substances to enhance the effectiveness of the active ingredient which modify the toxicity of the final product. The first part of this study is devoted to the development of analytical methods for the determination of glyphosate and its main metabolite, aminomethylphosphonic acid (AMPA), in aqueous and soil samples. An analytical method for the determination of non-ionic surfactants, auxiliary substances, generally added to commercial formulations, is then developed. In the second part the mobility of the herbicide in soils located in the Mediterranean area is investigated with special focus in those aspects related to the sorption and degradation processes. Finally, a comparison of the behaviour of different glyphosate-containing commercial herbicides is made.

Page generated in 0.2311 seconds