• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Testování MEMS gyroskopů / Testing of MEMS gyroscopes

Hasík, Stanislav January 2016 (has links)
This diploma thesis presents theoretical information regarding MEMS gyroscopes their parameters and designs. The description of measurement chain be used for testing of MEMS gyroscopes in Honeywell International s.r.o. is presented. Special focus is devoted to: the Polytec MSA-500 system, the Standa goniometers and their controller, Peltier cell and its driver. The practical part of this thesis contains the description of the thermal control system and also the description of the developed “Measurement system” in the LabVIEW software which is used for controlling the goniometers position and the Peltier cell. The system is able to fully control two goniometer stages, align the surface of tested MEMS device to orthogonal position with respect to the Polytec MSA-500 measurement head and also control the temperature of the tested device. The last part of this thesis presents the tests of the MEMS gyroscope parameters with special focus to the MEMS gyroscope angle random walk and the bias dependence on the vacuum quality of the structure environment.
2

Ganganalytische Besonderheiten bei Patienten mit diabetischer Neuropathie am Ganganalysesystem GangAS

Surminski, Oleg 20 March 2003 (has links)
Diabetiker entwickeln nach durchschnittlich 10 Jahren Folgeschäden. Die Polyneuropathie mit nachfolgender Osteoarthropathie des Fußes ist eine meist zu spät erkannte und suboptimal versorgte Komplikation. Nicht rechtzeitig erkannte Schäden führen zu Ulcera, sekundären Infektionen, Osteomyelitiden und Amputationen. Fragestellung: Ist eine Ganganalyse incl. Posturographie in der Lage, eine evtl. bestehende Polyneuropathie zu verifizieren, um eine frühzeitige orthopädische Schuhversorgung vornehmen zu können? Material und Methoden: Es wurden Diabetiker (n = 73) mit (mittels Messung der Nervenleitgeschwindigkeit NLG) nachgewiesener Neuropathie und eine gesunde Vergleichsgruppe (n = 38) ohne Neuropathie am Ganganalysesystem GANGAS untersucht. Ergebnisse: Die Allgemeinparameter relative Geschwindigkeit, Schrittlänge und Kadenz, sowie die Belastungsparameter Fersen-, Mittelfuß-, Vorfußbelastung und Belastung beim Auftritt und Abstoß zeigten keine wesentlich signifikanten Unterschiede im Gruppenvergleich. Dagegen zeigte die Posturographie (apparative Untersuchung der Schwankung des Druckschwerpunktes beim Romberg-Test, welche durch die Länge und Geschwindigkeit beschrieben wurde) signifikante Unterschiede zwischen beiden Patientengruppen. So lag z.B. der Median der Weglänge des Druckschwerpunktes beim Test mit geschlossenen Augen bei den Diabetikern bei 21,27 cm und in der Vergleichsgruppe bei 15,4 cm (p = 0,007). Die Bewegungsgeschwindigkeit des Druckschwerpunktes beim Test mit geschlossenen Augen betrug im Median 1,33 cm/sec bei den Diabetikern und 0,96 cm/sec in der gesunden Vergleichsgruppe (p = 0,006). Beim Test mit offenen Augen ergab sich kein signifikanter Unterschied im Gruppenvergleich. Klinische Relevanz: Eine Instabilität des Ganges der Patienten mit diabetischer Neuropathie und entsprechenden Folgeschäden des Fußes läßt sich durch die Ganganalyse mit Standardparametern nach vorliegendem Datenmaterial nicht nachweisen. Die Posturographie ist eine einfache, zeitlich mit geringem Aufwand verbundene Methode, die mit statistischer Signifikanz die subjektiven Kriterien der klinisch-orthopädischen Frühdiagnostik sinnvoll ergänzen und damit die Verdachtsdiagnose eine diabetischen Fußes objektiv nachweisen kann, bevor bleibende Schäden am Fuß entstanden sind. / Every diabetic patient after about ten years develops secondary changes in different tissues. Polyneuropathy with consecutive osteoarthropathy of the foot often is recognized too late and suboptimal treated. Diabetic disorders recognized too late may lead to ulcera, secondery infections and even amputations. Question: Is standard gait analysis including posturography able to verify diabetic neuropathy in order to supply the patient with adapted orthopadic shoeware in time? Materials and methods: A group of diabetics (n=73) with proved neuropathy by measuring nerve conduction velocity and a healthy control group (n=38) without neuropathy were examined by the gait-analysis-system GANGAS. Results: The general parameters: relative speed, length of step and cadence as well as the loading parameters of the heel, middle foot and forefoot during treading and repulsion show no significant differences between both groups. Posturography however (apparative examination of the elongation of focal point of pressure (FPP) according to the Romberg test, described by length and speed) shows significant differences between both groups. For diabetics making the test with closed eyes the mean value of walking length of the FPP was 21,27 cm, for the healthy control persons it was only 15,4 cm (p = 0,007). Asimulary results were found for the speed of movement of FPP during the test with closed eyes: mean value in diabetics 1,33 cm/s and for the healthy control persons 0,96 cm/s (p = 0,006). During this test with open eyes there was no significant difference between both groups. Clinical Relevance: Walking instability of patients with diabetic neuropathy and corresponding sequential damage of the foot could not be proved by the current data with standard parameters. Posturography however is able to give additional information with statistical significance to the subjective criteria of the clinical-orthopedic early diagnosis and verify the diagnosis of a beginning diabetic foot before severe disorders have occured.
3

Fotometrie a spektroradiometrie zapouzdřených LED čipů / Photometry and spectroradiometry of LEDs

Vysoudil, Martin January 2012 (has links)
This thesis deals with the processing of light technical parameters and performance of key LED chips for their applications in lighting systems. The aim is to create a laboratory model for measuring the qualitative and quantitative parameters of highly luminous light LED emitted depending on the angle, using a spherical integrator 0.3 m, goniometer and fiber spektroradiometr /luxmeters. Goniometer is designed using modular optomechanical parts company Thorlabs. Due to the current passing through the LED chips heat up considerably. To light LED chip parameters tested were not affected by heat from the chip is required to pay the heat generated by a passive radiator. Another part of this thesis is the reconstruction of an older model spherical integrator. Reconstruction must be undertaken so as to ensure sufficient cooling again tested LEDs. Light scattered in the ball of the integrator is led by the optical cable to the spektroradiometr that are subsequently recorded its parameters. The second element used to measure the light produced by the LED source is photocell. Spherical integrator must be appropriately modified to indicate the two measuring elements and also meet the standards of determining the correctness of measurement. At the end of the measurement results will be compared with catalog values provided by the manufacturer.

Page generated in 0.0555 seconds