• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 475
  • 220
  • 17
  • 6
  • 6
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 727
  • 225
  • 183
  • 145
  • 129
  • 123
  • 104
  • 80
  • 77
  • 76
  • 69
  • 65
  • 63
  • 56
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
511

“Caudales máximos de diseño para una defensa ribereña en el Asentamiento Humano El Olivar de Lurín”

Flores Veliz, Juan Carlos January 2018 (has links)
El documento digital no refiere un asesor / Publicación a texto completo no autorizada por el autor / En vista de los acontecimientos ocurridos por el niño costero, ocasionando fuertes lluvias, huaicos, etc., sobre todo en la cuenca del río Rímac, Chillón y Lurín, y las consecuencias que puede causar este fenómeno climático “el niño costero”, se ha previsto la necesidad de proteger la ribera; en especial la ribera de un tramo de la cuenca del río Lurín. Con el fin, que las comunidades, asentamientos humanos, o agrupaciones agropecuarias queden protegidas tras las fuertes avenidas que han socavado a lo largo de los márgenes del río Lurín. Para este proyecto, se calcula el caudal máximo de diseño para diferentes periodos de retorno. Realiza un estudio que involucre el modelamiento hidráulico que será de referencia para la estructura de protección que se quiera diseñar, ya que en dichas zonas también, existen estructuras diversas, como la bocatoma de Lurín, lecho de secado, que corresponde a SEDAPAL, zonas agropecuarias, ganado, etc. El enfoque que se lleva a cabo en este estudio, tiene que ver con el cálculo y análisis de caudales máximos de diseño para varios periodos de retorno, que pueden ser utilizados para distintas estructuras de protección. Se recurre a varios métodos, entre ellos las distribuciones teóricas y el método empírico de Creager y el método de Fuller. También se halla el ajuste de datos de la muestra de caudales para un mayor análisis. / Trabajo de suficiencia profesional
512

Diseño de sistema de protección contra incendio en LQ8 poza de operaciones y ampliación casa de fuerza LQCC - minera Yanacocha

Linares Jara, Danny Milthon, Linares Jara, Danny Milthon January 2014 (has links)
El documento digital no refiere un asesor / El documento digital no refiere un asesor / Diseña hidráulicamente los sistemas de protección contra incendio a base de agua para el área LQ8 (La Quinua) y el área LQCC, para dar la confiabilidad de que el sistema trabajará en óptimas condiciones para la máxima demanda en concordancia a lo exigido por las normas aplicables. El propósito del diseño es controlar los riesgos que conllevan la ocurrencia de un incendio, a través de la detección efectiva y preventiva, además de la preparación efectiva en caso de emergencias. / Trabajo de suficiencia profesional
513

“Diseño hidráulico del sistema contra incendios de un almacén de productos eléctricos y la selección de la bomba pertinente”

Jimenez Asencio, Carlos Felix Arturo January 2018 (has links)
El documento digital no refiere un asesor / Publicación a texto completo no autorizada por el autor / El presente trabajo “Diseño hidráulico para una bomba contra incendio de un almacén de productos eléctricos” trata de determinar la presión y caudal necesarios que debe proporcionar la bomba de un sistema contra incendio para un almacén. Para ello se desarrolla el cálculo hidráulico de las áreas que demanden más potencia de bombeo y así determinar cuál es el área más crítica, para finalmente seleccionar la bomba apropiada con sus características y costos. / Trabajo de suficiencia profesional
514

Diseño del sistema de protección contra incendio a base de agua para almacenamiento de papel

Villar Navarro, Luis Alberto January 2016 (has links)
El documento digital no refiere un asesor / Publicación a texto completo no autorizada por el autor / La presente monografía técnica, pretende dar a conocer los criterios y procedimientos necesarios para establecer el diseño de un sistema de extinción contra incendio de un almacenamiento de papel, utilizando las normas pertinentes (locales e internacionales). El estudio se inicia con un marco teórico referente al tema, para posteriormente analizar las condiciones y requerimientos de las distintas zonas del predio a proteger, reconociendo los riesgos para luego mediante la aplicación de las normas y cálculos correspondientes evaluar las alternativas y sus resultados para una aplicación eficiente y económica a fin elegir los componentes del Sistema. Finalmente se aprecian los cálculos realizados a fin de determinar qué método de protección elegir, y a su vez se presentará un cuadro de costos observando la diferencia de aplicación entre el método control y método supresión contra incendios. / Trabajo de suficiencia profesional
515

Diseño hidráulico del canal de sección circular con tuberías HDPE corrugada para el sistema de riego en el distrito de Aparicio Pomares, provincia de Yarowilca, región de Huánuco

Valdez Gutierrez, Juan Carlos January 2018 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere asesor / Realiza el diseño hidráulico del canal de sección circular a flujo libre para un sistema de riego en el distrito de Aparicio Pomares, provincia de Yarowilca, región de Huánuco, considerando una tubería HDPE corrugada a las condiciones de topografía, acceso en el emplazamiento del canal. El canal de sección circular con la tubería corrugada HDPE a comparación con tubería HDPE lisa tiene mayor eficiencia hidráulica debido a que estas tuberías tienen el diámetro interior mayor que la tubería HDPE lisa, es decir a mayor diámetro mayor capacidad de conducción hidráulica. Para la conducción del canal de sección circular se considera las obras de derivación y protección garantizando así la mayor vida útil de infraestructuras de riego, para generar la mayor producción agrícola de la zona de estudio. Al optar por esta infraestructura, la población de la zona de estudio puede generar ingresos económicos con miras hacia una tecnificación en el sistema de riego. Afianza la mayor vida útil en las infraestructuras de riego para mejorar la producción agrícola. / Trabajo de suficiencia profesional
516

Soluções analíticas para transporte de hidrocarbonetos do petróleo em água subterrânea : avaliação determinística e probabilística do risco à saúde humana

Melo, Tirzah Moreira de January 2010 (has links)
O presente trabalho apresenta um estudo de caso de contaminação de solo e água subterrânea por derivados do petróleo em uma refinaria da região Sudeste do país, para o qual foram aplicados todos os níveis ou tiers da metodologia RBCA de avaliação de risco à saúde humana. Diferentes vias de exposição foram consideradas ao longo de toda a metodologia, a qual foi dividida em determinística, compreendendo os dois primeiros níveis, e estocástica, no caso do terceiro nível. Sobre a abordagem determinística, o modelo de Domenico (1987) para transporte de contaminantes em água subterrânea foi substituído por um conjunto de soluções analíticas que considera diferentes geometrias de fonte de contaminação para casos instantâneos e contínuos de liberação de contaminantes, permitindo que a metodologia RBCA também possa ser empregada mesmo quando o modelo de Domenico (1987) não se aplica. A comparação deste conjunto de soluções com outro utilizado apenas para comparar e confirmar a validade dos modelos escolhidos demonstrou grande estabilidade nas soluções, enquanto os modelos de comparação apresentaram instabilidade nas soluções para altos valores da variável tempo. Tal fato comprovou a viabilidade do emprego do conjunto de soluções analíticas proposto para avaliação de risco à saúde humana. No contexto da abordagem estocástica da estimativa do risco, o método de Monte Carlo foi empregado para propagação das incertezas sobre uma das soluções analíticas citadas anteriormente, da qual, por sua vez, foram extraídos os resultados para a simulação estocástica do risco para a via de contato dermal com água superficial contaminada por Benzeno. Os resultados da simulação estocástica demonstraram uma correlação muito grande do risco com a variável C (concentração do contaminante), a qual, por sua vez, foi modelada pela simulação estocástica da condutividade hidráulica. Logo, pode-se concluir que a condutividade hidráulica afeta a estimativa do risco, para o qual observou-se uma diferença de seis ordens de magnitude entre o valor mínimo e o máximo simulados e duas ordens de magnitude para o valor real do risco. / This dissertation presents a case study on soil and ground water contamination by components derived from petroleum in a refinery located in the Southeast region of Brazil. All of the RBCA health risk assessment methodology tiers were applied in this study. Different exposure pathways were considered throughout the methodology. Firstly, the deterministic approach which encompasses the first two tiers and secondly, the stochastic approach which addressed the third tier. Regarding the deterministic approach, the Domenico (1987) ground water contaminant transport model was replaced by a new set of analytical solutions that consider different geometries of contamination sources used in cases of instantaneous and continuous release of contaminants. This replacement allowed for the utilization of the RBCA methodology whenever the Domenico (1987) analytical model does not apply. A comparison between this set of analytical solutions with another set used to validate and testify the chosen set only, showed great solution stability response; whereas, the models of comparison have demonstrated instability for high values of the time variable. Such a fact proved the validity of the use of the proposed set of analytical solutions inserted in a health risk assessment context. In the context of the stochastic approach of risk estimation, the Monte Carlo method was employed to propagate uncertainties over one of the analytical solutions mentioned above, from which results were obtained to simulate dermal contact with contaminated surface water while swimming exposure pathway. The results of the stochastic simulation demonstrated a high correlation between the risk and the variable C (contaminant concentration), which was modeled by the hydraulic conductivity stochastic simulation. Hence, it may be concluded that the hydraulic conductivity affects the risk estimation, for which a difference of six orders of magnitude between the minimum and maximum simulated values and two orders of magnitude for the real risk value was observed.
517

Diseño hidráulico del sistema contra incendio en faja transportadora de mineral del edificio de zarandeo minera Cerro Verde - Arequipa

Calero Espinoza, César Augusto January 2018 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere asesor / Presenta el diseño hidráulico para la red de tuberías del sistema de protección contra incendio de faja transportadora C2-3220-CV-026 mineral del edificio de zarandeo, ubicado en la nueva unidad de producción de expansión de la minera Cerro Verde área 3240. El diseño hidráulico para una red de tuberías de acero, el acero SCH 40 es la más comercial para un sistema contra incendio, están basados en los fundamentos de la mecánica de fluidos, utilizando ecuaciones para el flujo turbulento en tuberías como las ecuaciones de Darcy-Weisbach, Colebrook y White, también ecuaciones empíricas de mayor uso y difusión en la ingeniería como la de HazenWilliams. El diseño de un sistema contra incendio debe ajustarse a los parámetros de las normas NFPA, FM que son de gran aceptación internacional y adoptada en algunos países. Para la presente monografía se hará uso de las normas NFPA 13 Norma para la Instalación de Sistemas de Rociadores, NFPA 14 Norma para la Instalación de Sistemas de Tubería Vertical y de Mangueras, FM 7-11 Property Loss Prevention Data Sheets - Belt Conveyors, donde se establecen los parámetros máximos y mínimos que corresponde al caudal, presión, velocidad y entre otros factores para el aseguramiento adecuado del ambiente a proteger ante posibles riesgos de incendio. / Trabajo académico
518

Simulação do movimento da água no solo utilizando modelo numérico

Biassusi, Marcelo January 2001 (has links)
Um dos principais desafios para o século XXI é o uso sustentável dos recursos hídricos. A agricultura é a maior usuária desse recurso, sendo responsável por aproximadamente 70% dos gastos globais de água. Para o uso racional da água é necessário o conhecimento das propriedades hidráulicas do solo na condição de não-saturação. A simulação do movimento da água no solo através da modelagem é uma ferramenta importante no entendimento do sistema solo-água-planta, pois permite a previsão e estudo do comportamento da redistribuição da água no solo de maneira eficiente. Porém a forte dependência entre os parâmetros hidráulicos do solo (teor de água, potencial matricial e condutividade hidráulica) fazem da modelagem um assunto complicado, necessitando de modelos numéricos que utilizem intervalos discretos de tempo e espaço. Esses intervalos devem ser suficientemente pequenos para que dentro de um intervalo as variações dos parâmetros hidráulicos sejam insignificantes. Nesta tese é proposto um algoritmo para a descrição do movimento vertical da água no solo, definindo o intervalo de tempo como função de uma variação máxima admissível do teor de água. O algoritmo foi testado para alguns conjuntos de dados hidráulicos de solos, utilizando as condições de contorno de um experimento de perfil instantâneo. A eficiência do algoritmo foi verificada em situações práticas, como na previsão do teor de água na Capacidade de Campo e na predição do tempo para ser atingida determinada condição de umidade no solo. Utilizando o algoritmo, também foram estudados o comportamento da retenção e dos parâmetros de condutividade em relação aos parâmetros de drenagem. Concluiu-se que o algoritmo descreve adequadamente o processo de redistribuição de água no solo utilizando intervalos suficientemente pequenos de tempo e espaço; a forma de discretização do tempo não comprometeu a acurácia das medidas; a previsão do teor de água na Capacidade de Campo e do tempo para ser atingida determinada condição de umidade no solo foram satisfatórias; e o algoritmo permite o estudo das relações entre os parâmetros hidráulicos do solo.
519

Estudo geotécnico de dois taludes da formação serra geral, RS

Perazzolo, Lilian January 2003 (has links)
Esta dissertação de mestrado apresenta um estudo sobre dois taludes coluvionares localizados na região nordeste do Rio Grande do Sul, inseridos no contexto geológico da Formação Serra Geral. Estes taludes apresentam características e comportamento geotécnico distintos. O objetivo desta dissertação é obter parâmetros de condutividade hidráulica e resistência ao cisalhamento dos solos presentes nos dois taludes, a fim de entender os diferentes processos de ruptura observados. Um dos taludes, denominado talude de Canastra, apresenta um processo de rastejo; este talude tem uma inclinação bastante suave e apresenta uma camada de colúvio sobre um solo residual de basalto vesicular. O talude de Canastra apresenta uma camada de transição entre o colúvio e o solo residual; os ensaios de condutividade hidráulica realizados em campo mostraram que esta camada é menos permeável do que o colúvio e o solo residual, formando uma camada quase impermeável e criando condições para a formação de dois níveis freáticos neste talude. Nos solos deste talude foi detectada a presença significante de argila expansiva (montmorilonita). O outro talude estudado, denominado de talude da rodovia RS470, apresentou uma ruptura abrupta após um período de intensa chuva. Este talude apresenta uma inclinação bastante íngreme e um solo coluvionar assente diretamente sobre basalto alterado. A condutividade hidráulica deste colúvio é bastante elevada. O colúvio apresenta pouca argila expansiva, sendo formado essencialmente por caulinita. Os ensaios ring shear, realizados para a obtenção de parâmetros de resistência ao cisalhamento residual nos solos dos dois taludes, apresentaram valores muito baixos de φr, inferiores a 10° Valores semelhantes foram encontrados por Pinheiro (2000) e Rigo (2000) em solos residuais de basalto da Formação Serra Geral. Foram realizadas simulações numéricas de fluxo d’água e de estabilidade destes taludes, na tentativa de verificar as condições em que aconteceram os escorregamentos.
520

Determinação da condutividade hidráulica não saturada de solos residuais com o permeâmetro Guelph e ensaios de laboratório / Determination of the hydraulic conductivity no saturated of residual soils with the Guelph permeameter and laboratory tests

Lisboa, Rafael Luis Lobato 10 February 2006 (has links)
Made available in DSpace on 2015-03-26T13:28:42Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1091644 bytes, checksum: e1d6af20cbbbd1a4c083a7271719354c (MD5) Previous issue date: 2006-02-10 / Hydraulic conductivities of three non-saturated soils of the Viçosa region were studied with field tests, using the Guelph permeameter, and laboratory tests. In the field, the tests were performed with one and two hydraulic head heights. The corresponding results were analyzed with theoretical models proposed by REYNOLDS and ELRICK (1985). In the laboratory, water retention curves and saturated hydraulic conductivities of the soils were determined, with which variation of the hydraulic conductivities with suction were obtained using VAN GENUCHTEN (1980) and GARDNER (1958) empirical formulations. Finally, the non-saturated hydraulic conductivities obtained with the Guelph permeameter and the ones determined in the laboratory were compared. With the exception of soil 03, in which the walls of the hole made to execute the field test smeared, the saturated hydraulic conductivities values obtained in the field and in the laboratory were similar. With respect to the hydraulic conductivities variation with suction, it was verified that field and laboratory results agreed better when GARDNER (1958) model was used to represent the water retention curves than when the VAN GENUCHTEN (1980) model was used. / A condutividade hidráulica de três solos não saturados da região de Viçosa-MG é estudada através de ensaios de campo, empregando o permeâmetro Guelph, e ensaios de laboratório. No campo, os ensaios foram realizados com uma e duas alturas de carga. Os resultados obtidos foram analisados com os modelos teóricos proposto por REYNOLDS e ELRICK (1985). No laboratório, as curvas de retenção de água dos solos e as condutividades hidráulicas saturadas foram determinadas, o que possibilitou a determinação da variação da condutividade hidráulica com a sucção, através das fórmulas empíricas de VAN GENUCHTEN (1980) e GARDNER (1958). Por fim, os valores da condutividade hidráulica não saturada fornecidos pelo permeâmetro Guelph foram comparados com os obtidos no laboratório. Com exceção do solo 03, no qual as paredes do furo escavado para a execução do ensaio de campo colmataram, as condutividades hidráulicas saturadas dos solos obtidas no campo e no laboratório foram praticamente iguais. Com relação à variação da condutividade hidráulica com a sucção, verificou-se que os resultados de campo e laboratório tiveram uma maior concordância quando se usou o modelo de GARDNER (1958) para representar a curva de retenção de água dos solos do que quando se usou o modelo de VAN GENUCHTEN (1980).

Page generated in 0.0704 seconds