• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude du couplage optomécanique dans une cavité de grande finesse. Observation du mouvement Brownien d'un miroir

Hadjar, Yassine 25 November 1998 (has links) (PDF)
The topic of this thesis is the theoretical analysis of theoptomechanical coupling effects in a high-finesse optical cavity, and the experimental realization of such a device.Radiation pressure exerted by light limits the sensitivity of high precision optical measurements. In particular, the sensitivity of interferometric measurements of gravitational wave is limited by the so called standard quantum limit. cavity with a movable mirror. The internal field stored in such cavity can be orders of magnitude greater than the input field, and it's radiation pressure force can change the physical length of the cavity. In turn, any change in the mirror's position changes the phase of the out put field. This optomechanical coupling leads to an intensity-dependent phase shift for thelight equivalent to an optical Kerr effect. Such a device can then be used for squeezing generation or quantum nondemolition measurements.In our experiment, we send a laser beam in to a high-finesse optical cavity with a movable mirror coated on a high Q-factor mechanical resonator. Quantum effects of radiation pressure become therefore, at low temperature, experimentally observable. However, we've shown that the phase of the reflected field is very sensitive to small mirror displacements, which indicate other possible applications of thistype of device like high precision displacements measurements. We've been able to observe the Brownian motion of the moving mirror. We've also used an auxiliary intensity modulated laser beam to optically excite the acoustic modes. We've finally obtained a sensitivity of2x10^(-19) m/sqrt(Hz), in agreement with theoretical prediction.
2

Spectroscopie Laser avec des cavités résonantes de haute finesse couplées à un peigne de fréquences : ML-CEAS et vernier effet techniques. Applications à la mesure in situ de molécules réactives dans les domaines UV et visible. / Cavity enhanced multiplexed comb spectroscopy : ML-CEAS and Vernier effect techniques Application : a UV Spectrometer for in situ measurements of reactive molecules.

Abd Alrahman, Chadi 25 October 2012 (has links)
La communauté de la chimie atmosphérique souffre d'un manque de mesures rapides, fiables résolues spatialement et temporellement pour un large éventail de molécules réactives (radicaux tels que NO2, OH, BrO, IO, etc). En raison de leur forte réactivité, ces molécules contrôlent largement la durée de vie et la concentration de nombreuses espèces clés dans l'atmosphère, et peuvent avoir un impact important sur le climat. Les concentrations de ces radicaux sont extrêmement faibles (ppbv ou moins) et très variable dans le temps et dans l'espace, ce qui impose un véritable défi lors de la détection. Dans la première partie de cette thèse, un spectromètre UV robuste, compacte et transportable est développé, exploitant la technique ML-CEAS pour mesurer à des niveaux très faibles (pptv et même en dessous) des molécules réactives d'importance atmosphérique, en particulier, les radicaux d'oxyde d'halogènes, afin de répondre aux besoins émergents. La technique ML-CEAS est basée sur le couplage d'un laser femtoseconde à blocage de modes à une cavité optique de haute finesse, qui agit comme un piège à photons pour augmenter l'interaction entre la lumière et l'échantillon de gaz intracavité. Cela permet d'améliorer fortement la sensibilité d'absorption. La limite de détection obtenue pour le radical IO est de 20 ppqv pour un temps d'acquisition de 5 minutes, ce qui est un résultat impressionnant. Dans la deuxième partie de cette thèse, une nouvelle technique spectroscopique est développée appelée effet Vernier, qui est également basé sur l'interaction entre un laser femtoseconde à blocage de mode et une cavité optique de haute finesse. Cette technique fournit une sensibilité de détection similaire à la technique ML-CEAS, mais l'avantage est que le nombre des éléments spectraux est donné par la finesse de la cavité optique et donc peut atteindre plusieurs dizaines de milliers. De plus, cette configuration simplifie le montage expérimental par la suppression du spectrographe qui est remplacé par une simple photodiode. Le temps d'acquisition d'un spectre peut être aussi réduit à moins d' 1 ms. / The atmospheric chemistry community suffers a lack of fast, reliable and space resolved measurements for a wide set of reactive molecules (e.g. radicals such as OH, NO3, BrO, IO, etc). Due to their high reactivity, these molecules largely control the lifetime and concentration of numerous key atmospheric species, and may have an important impact on the climate. The concentrations of such radicals are extremely low (ppbv or less) and highly variable in time and space, which imposes a real challenge during the detection. In the first part of this thesis, a compact, robust and transportable UV spectrometer is developed, exploiting the Mode-Locked Cavity Enhanced Absorption Spectroscopy (ML-CEAS) technique to measure pptv and sub-pptv levels of atmospherically important reactive molecules, in particular, halogen oxide radicals, to respond to the emerging needs. The ML-CEAS technique is based on coupling a Mode-Locked femtosecond laser to a high finesse optical cavity, which acts as a photon trap to increase the interaction between the light and the intracavity gas sample, which highly enhances the absorption sensitivity. The detection limit obtained for the IO radical is 20 ppqv (part per quadrillion), which is an impressive result. In the second part of this thesis, a new spectroscopic technique is developed, called Vernier effect, which is also based on the interaction between a mode-locked femtosecond laser with a high finesse optical cavity. This technique provides detection sensitivity similar to that of ML-CEAS technique, but the advantage is that the number of the spectral elements is given by the cavity finesse, so it can reach ten thousands, as well as this technique has a simple setup, where the spectrograph is replaced by a photodiode. Additionally, the time required to measure one output absorption spectrum can be less than 1 ms.
3

Maintien du couplage optique entre une ECDL et une cavité de haute finesse : application à la mesure ultrasensible de biréfringence induite par effet Kerr / Maintenance of the optical coupling between an External Cavity Diode Laser and a high finesse cavity : application to ultrasensitive measurement of birefringence induced by Kerr effect

Durand, Mathieu 23 July 2009 (has links)
Ce travail se place dans le cadre de la mesure ultrasensible d’anisotropie de phase optique que permet l’emploi adapté des cavités de très haute finesse. Pour stabiliser la fréquence laser sur une résonance de la cavité, un schéma d’asservissement reposant sur la rétroaction optique est utilisé.Une première partie décrit le couplage optique entre le laser et la cavité à travers l’analyse du comportement de la fréquence d’émission du laser auto-réinjecté. Une comparaison analytique théorie expérience a permis d’identifier les signaux d’erreur nécessaires au maintien durable de la fréquence du laser à l’exacte résonance d’un mode de la cavité. Après une description détaillée du dispositif d’asservissement, sa réalisation expérimentale sur une cavité de finesse de quelques milliers (F = 3 000)a démontré la possibilité de stabiliser la fréquence laser sur plus de dix heures avec une excursion résiduelle à la seconde de 375 Hz.Dans la deuxième partie, le développement précédent a été mis en œuvre sur une cavité de très haute finesse (F = 250 000) et a permis la mesure ultrasensible de biréfringence induite dans des gaz par effet Kerr. L’originalité du dispositif repose sur la mise à profit de la biréfringence résiduelle des miroirs de haute réflectivité.Elle est utilisée d’une part comme source à la rétroaction optique, et d’autre part comme biais optique à la mesure de la biréfringence du gaz. Une étude théorique et expérimentale détaillée des sources de bruit présent dans la chaîne de détection en fonction de la valeur du biais optique a permis de réaliser la mesure de déphasage au niveau du bruit de photons avec quelques mW de puissance laser. Ainsi, une sensibilité référence sur la mesure de déphasage Kerr de 3.10−13 rad a été démontrée pour un temps de mesure de 800 sec. Cette valeur record améliore de trois ordres de grandeur les déphasages Kerr précédemment mesurés. Le dispositif a été de plus mis à profit pour la mesure à faible champ électrique (< 40 V /mm) et à pression atmosphérique, des constantes de Kerr de différents gaz moléculaires et atomiques jusqu’à l’He. / The context of the work is the ultra-sensitive measurement of phase anisotropy permits by well-used of very high finesse cavity. To stabilize the laser frequency at the exact resonance of one cavity mode, a servo control based on optical feedback is used.In the first part, the optical coupling between laser and cavity is described through the comportment of the frequency of the self-locked laser. A comparison between experience and theory has permitted to identify the error signals in order to keep enduringly the laser frequency at the exact resonance. The experimental realization of the servo control into a 3 000 finesse cavity had demonstrated the stabilization of the laser frequency during more than ten hours with a residual one second excursion of 375 Hz.In the second part, the previous development has been used with a very high finesse cavity (F=250 000) to measure static Kerr birefringence in gases. The originality of the set-up is the use of the residual high reflectivity mirrors birefringence, firstly as the source of the optical feedback and secondly as an optical bias to measure the weak gas birefringence. An experimental and theoretical study of the noise according to the value of the optical bias has permitted a photon noise limited measurement (laser intensity of few mW). A record sensitivity of the phase shift induced by Kerr effect has been demonstrated at 3.10-13 rad with 800 s integration time. The scheme has been used to measure, in weak electric field (<40 V/mm) and in standard condition of pressure and temperature, the Kerr constant of molecular and atomic gases, even He gas

Page generated in 0.0957 seconds