Advanced test mass suspensions and electrostatic control for AIGO

Lee, Benjamin H January 2007 (has links)
This thesis presents the research done towards the development of the final mirror suspension stage for the high power test facility at AIGO, Western Australia. One of the goals of the facility is to test advanced suspension methods that may be useful in future gravitational wave detectors. An in depth study of current mirror suspension techniques is presented and areas of possible improvement are highlighted. The extension of an existing suspension modelling toolkit written in Mathematica is also presented, where added functions allow one to include the violin modes of a suspension into their analysis. Through this tool, new suspension geometries boasting a lower number of violin modes with lower Q factors where developed. The orthogonal ribbon suspension and the thin tube suspension boast a lower number of lower Q violin modes compared to typical ribbon suspensions. For the latter, a reduction in the number of violin modes below 5kHz down to 5 and peak thermal noise amplitude by approximately 30dB is predicted. Presented also is the affect that such suspension geometries have on pendulum mode dilution factor and overall suspension thermal noise. It is seen that the violin mode improvement comes at a cost of a small increase in thermal noise above approximately 50Hz. A theoretical analysis of the AIGO cavity locking control scheme is also given. Issues of sensor noise and dynamic range are considered to produce a possible hierarchical locking method that would be compatible with advanced detectors. The resulting actuator force range requirements for AIGO at each actuation location on the vibration isolation system are given. Requirements of local controls before achieving cavity lock are also discussed. Finally, the suspension of a dummy sapphire mirror using removable modular niobium ribbons is presented. The design and performance of an electrostatic actuator and sensor for suspended mirror control is given. Initial experimental results of positioning and control of the final stage suspension through a digital interface is also included.
2

Etude du couplage optomécanique dans une cavité de grande finesse. Observation du mouvement Brownien d'un miroir

Hadjar, Yassine 25 November 1998 (has links) (PDF)
The topic of this thesis is the theoretical analysis of theoptomechanical coupling effects in a high-finesse optical cavity, and the experimental realization of such a device.Radiation pressure exerted by light limits the sensitivity of high precision optical measurements. In particular, the sensitivity of interferometric measurements of gravitational wave is limited by the so called standard quantum limit. cavity with a movable mirror. The internal field stored in such cavity can be orders of magnitude greater than the input field, and it's radiation pressure force can change the physical length of the cavity. In turn, any change in the mirror's position changes the phase of the out put field. This optomechanical coupling leads to an intensity-dependent phase shift for thelight equivalent to an optical Kerr effect. Such a device can then be used for squeezing generation or quantum nondemolition measurements.In our experiment, we send a laser beam in to a high-finesse optical cavity with a movable mirror coated on a high Q-factor mechanical resonator. Quantum effects of radiation pressure become therefore, at low temperature, experimentally observable. However, we've shown that the phase of the reflected field is very sensitive to small mirror displacements, which indicate other possible applications of thistype of device like high precision displacements measurements. We've been able to observe the Brownian motion of the moving mirror. We've also used an auxiliary intensity modulated laser beam to optically excite the acoustic modes. We've finally obtained a sensitivity of2x10^(-19) m/sqrt(Hz), in agreement with theoretical prediction.