• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 27
  • 6
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 83
  • 23
  • 20
  • 15
  • 15
  • 14
  • 14
  • 14
  • 12
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Analysis Of Fiber Reinforced Composite Vessel Under Hygrothermal Loading

Sayman, Sumeyra 01 January 2004 (has links) (PDF)
The aim of this study is to develop an explicit analytical formulation based on the anisotropic elasticity theory that determines the behavior of fiber reinforced composite vessel under hygrothermal loading. The loading is studied for three cases separately, which are plane strain case, free ends and pressure vessel cases. For free-end and pressure vessel cases, the vessel is free to expand, on the other hand for plane strain case, the vessel is prevented to expand. Throughout the study, constant, linear and parabolic temperature distributions are investigated and for each distribution, separate equations are developed. Then, a suitable failure theory is applied to investigate the behavior of fiber reinforced composite vessels under the thermal and moisture effects. Throughout the study, two computer programs are developed which makes possible to investigate the behavior of both symmetrically and antisymmetrically oriented layers. The first program is developed for plane strain case, where the second one is for pressure vessel and free-end cases. Finally, several thermal loading conditions have been carried out by changing the moisture concentration and temperature distributions and the results are tabulated for comparison purposes.
52

Klimarandbedingungen in der hygrothermischen Bauteilsimulation. Ein Beitrag zur Modellierung von kurzwelliger und langwelliger Strahlung sowie Schlagregen / Climatic boundary conditions in hygrothermal building part simulation. A contribution to the modelling of shortwave and longwave radiation and driving rain

Fülle, Claudia 21 July 2011 (has links) (PDF)
Nachhaltige Architektur erfordert neue Bauformen, innovative Konstruktionen und die Verwendung neuartiger Baumaterialien. Zur Abschätzung des Risikos von feuchtebedingten Schäden finden Programme der hygrothermischen Bauteilsimulation Anwendung. Bei der Entwicklung solcher Simulationsprogramme spielt die korrekte Modellierung der Klimarandbedingungen eine entscheidende Rolle. Beim Übergang von der kurzwelligen horizontalen Strahlungsstromdichte auf die kurzwellige Strahlungsstromdichte eines beliebigen Bauteils müssen Himmelsrichtung der Flächennormalen und die Neigung des Bauteils zum Ausschluss von Eigenverschattung berücksichtigt werden. Das dargestellte integrale Modell erlaubt die Berechnung und Programmierung in einem hygrothermischen Simulationsprogramm. Für den Fall, dass nur Messwerte der globalen Strahlungsstromdichte zur Verfügung stehen, können die direkten und diffusen Anteile mithilfe geeigneter Modelle mit einer sehr guten Genauigkeit berechnet werden. Zur Berechnung der langwelligen Strahlungsbilanz eines Bauteils stehen nur selten jene Klimaparameter zur Verfügung, mit denen die atmosphärische langwellige Strahlungsflussdichte analytisch bestimmt werden kann, weshalb semi-empirische Modelle Anwendung finden müssen. Die langwellige Ausstrahlung der Atmosphäre kann mithilfe von bodennaher Lufttemperatur und Luftfeuchte sowie zweier Bedeckungsgrad-Indizes berechnet werden, welche die langwelligen Strahlungseigenschaften der Atmosphäre auf der Basis der vorhandenen kurzwelligen Strahlungsstromdichten beschreiben. Damit wird erstmals ein umfassendes Modell für die langwellige Strahlungsbilanz vorgelegt, welches alle Möglichkeiten der Datenverfügbarkeit berücksichtigt. Die Berechnung der Schlagregenstromdichte auf ein Bauteil kann mit den meisten vorliegenden semi-empirischen Modellen nur sehr ungenau erfolgen. Andere Verfahren, wie z.B. CFD-Simulationen, kommen wegen des beträchtlichen Aufwands meist nicht in Frage. Das bislang einzige vorliegende umfassende validierte semi-empirische Modell von Blocken kann durch die Berücksichtigung der mesoklimatischen Verhältnisse in seiner Genauigkeit verbessert werden. / Sustainable architecture requires new building design, innovative constructions and the use of newly developed building materials. In order to determine the risk of moisture-related damages, computer programs for hygrothermal building part simulation are being used. If one develops such a simulation program, correct modelling of climatic boundary conditions plays an important role. When calculating the shortwave solar radiation flux density at an arbitrary building part on the basis of the shortwave solar radiation flux density on the horizontal surface, one must take into consideration the orientation and the inclination of the building part in order to preclude self-shading. The presented integral model allows the calculation and the programming in a hygrothermal simulation program. If only measured values of global radiation flux density are available, direct and diffuse parts can be determined very precisely by means of validated models. When calculating the longwave radiation balance on a building part, the needed values for the correct determination of atmospheric longwave radiation are hardly available. That’s why semi-empirical models will be applied. The longwave radiation flux density of the atmosphere can be determined on the basis of near-ground temperature and relative humidity and two cloud cover indices, which describe the longwave irradiative properties of the atmosphere by means of available shortwave radiation flux densities. Therewith, firstly an integral model is being presented in order to determine longwave radiation balance, which considers all possibilities of data availability. Most models for determination of driving rain load work with very bad accuracy. Other methods such as computational fluid dynamics (CFD) are not possible for hygrothermal building part simulations because of the huge effort. The only fully validated semi-empirical model by Blocken can be improved, if meso-climatic boundary conditions are taken into consideration.
53

Étude des mécanismes de transferts couplés de chaleur et d’humidité dans les matériaux poreux de construction en régime insaturé / Study of coupled heat and moisture transfer mechanisms in porous building materials in unsaturated regime

Bennai, Fares 28 June 2017 (has links)
Le présent travail a pour objectif de comprendre l’influence des paramètres géométriques des éco-matériaux d’enveloppe, tels que le béton de chanvre, sur les mécanismes de transferts couplés de chaleur, d'air et d’humidité afin de prédire le comportement du bâtiment dans le but de le piloter et de l’améliorer dans sa durabilité. Pour cela, une approche multi-échelle est mise en place. Elle consiste à maîtriser les phénomènes physiques dominants et leurs interactions à l’échelle microscopique. S’ensuit, une modélisation à double échelle, microscopique–macroscopique, des transferts couplés de chaleur, d’air et d’humidité qui prend en compte les propriétés intrinsèques et la topologie microstructurale du matériau moyennant le recours à la tomographie rayon X conjuguée à la corrélation d’images 2D et 3D. Pour cela, une campagne de caractérisation fine des propriétés physiques et hygrothermiques du béton de chanvre confectionné au laboratoire a été réalisée. Elle s’est focalisée sur l’étude de l’impact du vieillissement, l’état thermique et hydrique du matériau sur ses propriétés intrinsèques. Les résultats montrent une excellente capacité d'isolation thermique et de régulation naturelle d’humidité du béton de chanvre. Puis, une caractérisation microscopique par différentes techniques d’imagerie a été effectuée. Les reconstructions 3D du matériau réel scanné au tomographe aux rayons X à différentes résolutions montrent que le béton de chanvre possède plusieurs échelles de porosité, allant de la microporosité au sein du liant et des chènevottes à la macroporosité inter-particulaire. Le comportement hygro-morphique sous sollicitations hydriques a été ensuite étudié. Les résultats de la corrélation d’image numérique 2D et de la tomographie aux rayons X couplés à la corrélation d’images volumiques, montrent la nature du comportement du béton de chanvre soumis à des hygrométries différentes. En effet, la chènevotte subit des déformations plus importantes que le liant, causant ainsi des modifications de la microstructure du matériau. Sur le volet de la modélisation, moyennant la technique d’homogénéisation périodique un modèle des transferts couplés de chaleur, d’air et d’humidité dans les matériaux poreux de construction a été développé. Les tenseurs de diffusion et de conductivité thermique homogénéisés ont été calculés numériquement. Ensuite, une confrontation entre les résultats du calcul des coefficients de diffusion macroscopique et ceux expérimentaux obtenus au LaSIE a été réalisée. Elle met en évidence la qualité de la prédiction. De plus, la conductivité thermique de la phase solide a été ainsi déduite. Les résultats obtenus dans le cadre de ce travail de thèse ont mis en exergue l’influence de l’état hydrique et thermique du béton de chanvre sur ces propriétés intrinsèques, et sa microstructure très hétérogène. Ils ont révélé aussi les limites des approches phénoménologiques basées sur l’établissement des bilans de masse, de quantité de mouvement et d’énergie. / The aim of this work is to understand the influence of the geometric parameters of envelope eco-materials, such as hemp concrete, on the mechanisms of coupled heat, air and moisture transfers, in order to predict behavior of the building to control and improving it in its durability. For this a multi-scale approach is implemented. It consists of mastering the dominant physical phenomena and their interactions on the microscopic scale. Followed by a dual-scale modeling, microscopic-macroscopic, of coupled heat, air and moisture transfers that takes into account the intrinsic properties and microstructural topology of the material using X-ray tomography combined with the correlation of 2D and 3D images. A characterization campaign of physical and hydrothermal properties of the hemp concrete manufactured in the laboratory was carried. It focused on studying the impact of aging, thermal and hydric state of the material on these intrinsic properties. The results show an excellent thermal insulation and natural moisture regulation capacity of hemp concrete. Then, a microscopic characterization by different imaging techniques was performed. The 3D reconstructions of the real material scanned with X-ray tomography at different resolutions show that hemp concrete has several scales of porosity, ranging from micro-porosity within the binder and hemp shiv to the inter-particle macro-porosity. The hydromorphic behavior under hydric solicitations was studied. The results of the 2D digital image correlation and X-ray tomography coupled with the volumetric image correlation show the nature of the behavior of hemp concrete subjected to different relative humidities. In fact, the hemp shiv undergoes greater deformations than the binder, thus causing changes in the microstructure of the material. On the modeling part, a model of coupled heat, air and moisture transfer in porous building materials was developed using the periodic homogenization technique. The homogenized tensors of diffusion and thermal conductivity were determined numerically. Then, a confrontation between the results of the calculation of the macroscopic diffusion coefficients and the experimental results obtained at the LaSIE was carried out. It highlights the quality of the prediction. In addition, the thermal conductivity of the solid phase was thus deduced. The results obtained in the framework of this PhD thesis have highlighted the influence of the hydric and thermal state of the hemp concrete on these intrinsic properties and its very heterogeneous microstructure. They also revealed the limitations of phenomenological approaches based on the establishment of the balances of mass, amount of motion and energy
54

Modelling and experimental validation of the hygrothermal performances of earth as a building material / Modélisation et validation expérimentale des performances hygrothermiques de la terre comme matériau de construction

Soudani, Lucile, Caroline, Laurence 09 December 2016 (has links)
La thèse s'inscrit dans un projet de recherche national (ANR Primaterre) qui a pour but d'étudier les performances (mécaniques et thermiques) réelles des matériaux de construction premiers à faible énergie grise que sont la terre crue et la limousinerie.Le travail de thèse se concentre sur les aspects thermiques et hygrothermiques de la terre crue, c'est-à-dire le couplage entre les transferts de masse d'eau (liquide et vapeur) et de chaleur au sein du matériau. Dans une première partie, une analyse des performances thermiques et hydriques d'une habitation comportant des murs en pisé (terre crue compactée) instrumentés a été réalisée. Cette étude a été complétée par la mesure, en laboratoire, des propriétés thermiques et hydriques du matériau. Le lien entre les paramètres matériaux mesurés et les performances (hygro)-thermiques a été appréhendé à la lumière d'un modèle numérique couplé, adapté aux caractéristiques particulières du matériau. Cette étude a mis en évidence que, de par leur aptitude à stocker puis restituer l'énergie solaire, leur capacité de stockage hydrique et la complexité des transports et changements de phases de l'eau se produisant en leur sein, les murs en terre crue présentent de nombreuses particularités qu'il convient de prendre en compte pour une bonne prédiction de leur impact sur les performances d'une habitation. / The Ph.D. is part of a national research project (ANR Primaterre) aiming at promoting real performances (mechanical and thermal) of primary construction materials with low embodied energy such as raw earth.This work focuses on the thermal and hygrothermal behaviour of rammed earth, i.e. coupled transfers of heat and moisture (liquid water and water vapour) within the material. On the one hand, an evaluation of the thermal and hygric performances of a monitored house with rammed earth walls is provided. This study is completed with laboratory measurements of the thermal and hydric properties of the material. A numerical coupled model, suitable for the specific characteristics of the material, provides a better understanding of the link between the characterization parameters measured and its (hygro)thermal performances. Because of their ability to store and release heat from the sun, their capacity to store moisture and the complexity of the transfers occurring in their pores, earthen walls display many distinctive features that are essential to count for in order to provide an accurate prediction of their impact on the global performances of a building.
55

Relations entre microstructure et propriétés physico-chimiques et mécaniques de revêtements époxy modèles / Relations between microstructure and physico-chemical and mechanical properties of model epoxy coatings

Bouvet, Geoffrey 19 December 2014 (has links)
Ce travail de thèse porte sur l’étude et la mise en évidence de relations microstructure-propriétés dans des revêtements modèles à base époxy représentatifs de peinture anticorrosion. Ces relations sont établies aussi bien à l’état initial que lors de vieillissements hygrothermiques. Cette étude a tout d’abord consisté à caractériser les propriétés physico-chimiques et mécaniques du système stœchiométrique DGEBA/DAMP totalement réticulé. Ces propriétés ont été comparées à celles du système DGEBA/TETA et ont permis de montrer la forte influence de la microstructure sur ces propriétés initiales. Des vieillissements hygrothermiques cycliques à différentes températures sur films libres ont été effectués pour mesurer l’impact de la microstructure sur la durabilité des systèmes époxy. Ces travaux ont pu montrer l’influence des interactions eau-polymère dans les phénomènes de diffusion. De plus, les évolutions de certaines propriétés physico-chimiques et mécaniques ont pu être caractérisées à l’aide de la DMA (mors submersibles), lors des différentes étapes de sorption-désorption. Un comportement pseudo-fickien a pu être mis en évidence lors de la première sorption, suivi d’un comportement fickien lors des autres étapes. Les causes inhérentes à cette évolution ont pu être avancées, en mettant en jeu des réorganisations microstructurales des systèmes époxy étudiés. D’autres vieillissements hygrothermiques ont été réalisés à l’aide de la SIE sur des revêtements pour étudier l’effet de l’interface revêtement/substrat acier sur les phénomènes de diffusion, notamment le rôle des contraintes résiduelles. L’influence de la contrainte visco-élastique sur les phénomènes de prise en eau des revêtements a finalement été étudiée. / This work highlights the microstructure-properties relations inside representative epoxy based model coatings for anticorrosion paints. These relations have been established for the initial state as well as the hygrothermal ageing. First, we characterised physico-chemical and mechanical properties of the totally crosslinked DGEBA/DAMP stoichiometric system. These properties have been compared to the DGEBA/TETA system and they showed the strong influence of the microstructure on these initial properties. Cyclic hygrothermal ageing have been completed at different temperatures on free films, in order to measure the impact of the microstructure on the durability of epoxy systems. This work has shown the influence of the water-polymer interactions on diffusion phenomena. Moreover, the evolutions of several physico-chemical and mechanical properties have been characterised using DMA (submersible clamps), during different sorption-desorption steps. A pseudo-fickian behaviour has been evidenced during the first sorption, and it was followed by a fickian behaviour for all other steps. The inherent causes of this evolution have been proposed, by considering microstructural reorganisations of the studied epoxy systems. Other hygrothermal ageing have been carried out using EIS on coatings, in order to study the effects of the coating/steel substrate interface on diffusion phenomena, especially the role of residual stresses. We finally studied the influence of the visco-elastic stress on the coating water intake phenomena.
56

Modélisation des transferts thermo-hydro-aérauliques dans les enveloppes de bâtiments : évaluation des désordres causés par l'humidité / Modeling of thermo-hygro-aeraulic transfers in buildings envelopes : assessment of disorders caused by humidity

Ferroukhi, Mohammed Yacine 01 December 2015 (has links)
Ces travaux de thèse s’inscrivent dans le cadre du projet ANR HUMIBATex « Comment prédire les désordres causés par l’humidité ? Quelles solutions techniques pour rénover le bâti existant ? » (2012-2016). Elle traite de la modélisation numérique et expérimentale des transferts couplés hydro-thermo-aérauliques à différentes échelles : matériau, paroi et ambiance de bâtiment. Sur le plan théorique, un modèle phénoménologique des transferts couplés de chaleur, d’air et d’humidité à travers les enveloppes de bâtiments (HAM) a été élaboré. Après la phase de validation (confrontation avec des solutions analytiques et des résultats expérimentaux), ce modèle a été implémenté avec confiance dans un code de simulation thermique dynamique du bâtiment (BES). Ceci a permis, ainsi, de développer une plateforme de co-simulation HAM-BES. Grâce à l’outil mis en œuvre, les comportements hygrothermiques de la paroi et de l’ambiance habitable des bâtiments ont été prédits finement. Deux cas d’études ont été entrepris. Le premier avait pour but de mettre en évidence l’impact des transferts hygrothermiques sur la prédiction des consommations énergétiques. Le deuxième cas d’étude a été dédié à l’étude de l’efficacité de différentes stratégies de ventilation (extraction ou insufflation) sur le contrôle et la diminution des risques d’apparition de désordres liés à l’humidité au niveau des bâtiments résidentiels. Sur le plan expérimental, une campagne de caractérisation des propriétés physiques, hydriques et thermophysiques des matériaux de construction a été effectuée. Cette campagne expérimentale s’est focalisée sur l’analyse de l’impact de l’état thermique et hydrique du matériau sur les valeurs des propriétés hygrothermiques. Dans un autre travail expérimental, des dispositifs expérimentaux, à petite échelle mais également à l’échelle de la paroi, ont été conçus au laboratoire dans le but d’étudier la réponse hygrothermique des enveloppes de bâtiment ainsi que valider la plateforme de co-simulation dynamique HAM-BES. La confrontation des résultats a montré une bonne concordance entre la résolution numérique et les mesures expérimentales. Les résultats obtenus dans le cadre de ce travail de thèse ont mis en exergue l’influence d’une modélisation fine des transferts couplés de chaleur, d’air et d’humidité, à la fois sur la prédiction du comportement hygrothermique des ambiances habitables mais aussi sur le calcul des besoins énergétiques des bâtiments. / The present PhD thesis work is conducted in the framework of the National Program ANR HUMIBATex Project « How to predict the disorders caused by moisture? What technical solutions to renovate the existing buildings? ». It deals with the numerical and experimental modeling of a coupled heat, air and moisture transfers at different scales: material, envelope and building ambience. In the theoretical part, based on expression of heat and moisture (vapor, liquid and air) balances equations, a phenomenological model describing the coupled heat, air and moisture transfer (HAM) through the wall has been developed. After validation stage (comparison with experimental results and analytical solution), the model has been implemented with confidence in a building energy simulation code (BES). Using this HAM-BES dynamic co-simulation tool, the hygrothermal behavior of the wall and indoor air of buildings were predicted finely. Two cases studies have been undertaken. The aim of the first one was to highlight the impact of hydrothermal transfers on the prediction of building energy consumption. However, the second case study was devoted to study efficiency of different ventilation strategies (extracting or insufflation) on the control and reduction of disorders caused by moisture in residential buildings. In the experimental part, a characterization campaign of physical, hydric and thermophysical properties of construction materials has been carried out. This experimental campaign has been focused on analyzing of the impact of thermal and hydric state of the construction material on the hygrothermal properties values. In another work, several experimental devices, at small-scale and wall scale, were designed in the laboratory to study the hygrothermal response of different building envelopes configuration and validate the developed HAM-BES dynamic co-simulation platform. Results of confrontation have showed good agreement between the numerical solution and experimental measurements.The obtained results in the framework of this PhD thesis have highlighted the influence of a detailed modeling of coupled heat air and moisture transfer through the wall on the hygrothermal behavior prediction of the indoor air, on assessment of pathology indicators and on the evaluation of the buildings energy loads.
57

Élaboration et caractérisation d'un agromatériau chanvre-amidon pour le Bâtiment / Elaboration and characterization of hemp-starch material

Umurigirwa, Benitha Sandrine 09 December 2014 (has links)
Afin de diminuer les consommations énergétiques, plusieurs pays Européens, y compris la France, ont mis au point de nouvelles normes permettant d'optimiser les performances énergétiques de l'enveloppe du bâtiment. Ceci peut entraîner l'augmentation de l'humidité relative, ce qui peut nuire à la santé des occupants et dégrader la structure du bâtiment. Utiliser des éco-matériaux tel que le béton de chanvre est une solution prometteuse permettant d'assurer le confort à l'intérieur du bâtiment, en régulant l'humidité relative. L'objectif principal de cette thèse est d'élaborer, optimiser et caractériser un agromatériau à base de la chènevottes défibrée avec un liant d'amidon de blé. La formulation du chanvre-amidon est étudiée en variant le rapport massique amidon/chanvre et son impact sur les propriétés mécaniques. Le coefficient d'absorption acoustique est mesuré pour la composition optimale. Pour améliorer les propriétés d'adhésion à l'interface chanvre/amidon, un traitement de surface à base d'hydroxyde de sodium NaOH suivi par un agent de couplage (3-glycidyloxypropyl) triméthoxysilane ont été effectués. L‘influence du traitement de surface sur les fibres de chanvre a été analysée au microscope électronique à balayage (MEB), par la calorimétrie différentielle à balayage (DSC), l'analyse thermographique (ATG) et par la spectroscopie infrarouge à transformée de Fourier (FTIR). Les propriétés hygrothermiques du matériau chanvre-amidon avec et sans traitement de fibres sont également étudiées. Ces propriétés comprennent la courbe d'isotherme de sorption, la perméabilité à la vapeur d'eau, la conductivité thermique et la capacité tampon hydrique du matériau. / In order to control energy consumption, several European countries including France, adopted regulations to optimize the energy performance of the building envelope. This fact could increase the level of indoor relative humidity which can affect the health of the occupants and causes material damage. Using eco-friendly materials such as hemp concrete which can buffer indoor moisture levels might contribute to maintain high indoor comfort.The main purpose of this thesis is to optimise and characterize a construction material made of hemp hurds and wheat starch binder.The formulation of the hemp-starch is studied by varying starch/hemp ratio and its impact on mechanical properties. Sound absorption coefficient is measured for optimal composition. To improve the adhesion between hemp fibers and starch matrix, alkali treatment with sodium hydroxide was performed to solubilize hemicelluloses and lignin seal surrounding the cellulose bundle in the first step and then a silane coupling agent (3-glycidyloxypropyl) trimethoxylsilane was used to provide a stable bond between hemp fibres and starch matrix. The influence of the treatments were investigated by scanning electron microscopy (SEM), differential thermal analysis (DTA), thermogravimetric analysis (TGA) and attenuated total reflectance spectroscopy (ATR). After the treatments, mechanical properties of hemp-starch material were studied.Hygrothermal properties of hemp-starch material with and without fibre treatment were also measured. These properties include sorption isotherm curve, water vapour permeability, thermal conductivity and moisture buffering value.
58

Formulation et caractérisation d'un composite terre-fibres végétales : la bauge / Formulation and characterization of earth-plant fibres composite

Phung, Tuan anh 28 May 2018 (has links)
La terre est le premier matériau de construction par les hommes, disponible et peu consommateur d’énergie. Aujourd’hui encore, environ 30 % des habitants de la planète vit dans des habitats en terre, et pour les pays en développement, ce pourcentage s’élève à 50 % de la population rurale. De plus, les matériaux à base de terre permettent un meilleur équilibre et contrôle du climat thermique et acoustique intérieur par rapport aux matériaux usuels de construction. Cependant, la majorité des constructions en terre ne répondent pas aux exigences actuelles en termes de contraintes mécaniques, thermiques ou architecturales. Afin de répondre à ces exigences, un travail tant au niveau scientifique qu’au niveau des praticiens est à accomplir dans ce domaine.L’objectif de cette étude est de déterminer l’influence des propriétés des matériaux utilisés sur le comportement mécanique et hygrothermique de composites terre-fibres végétales. Pour cela, différents types de sols et de fibre végétales (paille de lin, paille de blé) ont été utilisés. Ensuite, les performances mécaniques (compression, flexion) et hygrothermiques (sorption/désorption, perméabilité à la vapeur d’eau, conductivité thermique) ont été déterminées pour différents composites terre-fibres végétales. Les résultats montrent que l’utilisation de paille de lin permet d’obtenir des performances mécaniques supérieures à celles obtenues pour la paille de blé. Cependant, il est à noter que l’introduction de fibres aux sols diminue les performances mécaniques due à la diminution de la densité du matériau. Aucune influence claire de la longueur des fibres sur les performances mécanique n’a été constatée. L’étude du comportement hygrothermique a permis de montrer que le comportement à la sorption/désorption du matériau terre-fibres végétales peut être approximer à partir des résultats obtenus pour les matériaux de base. De plus, il a été démontré que l’évolution de la conductivité thermique du matériau terre-fibres végétales au cours du séchage est reliée au comportement au retrait. / Soil is the first construction material used by man, widely available and low energy consuming. Indeed, about 30% of the current world population lives in earthen structures and, in developing countries, this rate rise to 50%, mostly rural. Moreover, earth-based materials allow an improved balance and control of thermal and acoustic indoor climate compared to industrial construction materials. However, most of earthen structures do not reach current requirements in terms of mechanical, thermal or architectural. To respond to these requirements, a work at scientific and craftsman levels is necessary.The objective of this study is to determine the influence of materials’ properties on the mechanical and hygrothermal behaviour of earth-fiber composites. In order to do this, different types of soil and plant fiber (flax straw, wheat straw) were used. Then, mechanical (compression, bending) and hygrothermal performances (sorption / desorption, water vapor permeability, thermal conductivity) were determined for different soil-fiber composites. Results show that the use of flax straw provides better mechanical performances than use of wheat straw. However, it should be noted that fibers addition to soil decreases mechanical performance due to the decrease of material density. No clear influence of fiber length on mechanical performance was found. The study of hygrothermal behaviour has shown that the sorption / desorption behaviour of earth-fiber material can be approximated from the results obtained from basic materials. In addition, it has been shown that the thermal conductivity evolution of earth-fiber material during drying is related to the shrinkage behaviour.
59

EOPEBEC - Etude et optimisation des performances énergétiques d’une enveloppe en béton de chanvre pour le bâtiment / Study and optimization of energy performance of a hemp concrete building envelope

Costantine, Georges 19 October 2018 (has links)
Dans un contexte de réchauffement climatique et de fin programmée des énergies fossiles, le secteur du bâtiment vise à réduire de 38% sa consommation d’énergie et à atteindre 10% de matériaux bio-sourcés utilisés dans la construction à l’horizon 2020. Ainsi, le béton de chanvre peut jouer un rôle majeur grâce à son bilan environnemental et à ses propriétés hygrothermiques qui lui permettent d’assurer un rôle d’amortisseur thermique et de stabilisateur de confort. Or le comportement hygrothermique du béton de chanvre à l’échelle du bâtiment est peu abordé dans la littérature et jamais pour les bâtiments tertiaires. L’objectif principal de ce projet est de combler ce vide en étudiant et en optimisant les performances énergétiques d’un bâtiment en béton de chanvre destiné à usage de bureaux et/ou de salles d’enseignement. Afin d’assurer le confort thermique intérieur différentes solutions techniques seront couplées au bâtiment et comparées entre elles : - une ventilation double flux thermodynamique associant une pompe à chaleur à une centrale double flux. - Une ventilation simple flux associé à un puits canadien qui récupère la chaleur du sous-sol pour préchauffer l’air de ventilation en hiver ou le rafraîchir en été. - Une ventilation double flux associé à un puits canadien. Par le biais de la simulation numérique et de mesures faites d’abord à l’échelle des composants, il sera ainsi possible d’évaluer le potentiel de chaque composant sur l’énergétique et le confort hygrothermique de bâtiments tertiaires intégrant principalement le périmètre du projet Grand Campus de Reims mais également pouvant être élargi à la spécificité d’autres climats français. / In a context of global warming and planned end of fossil fuels, the construction industry aims to reduce by 38% its energy consumption and to achieve 10% of bio-based materials used in construction in 2020. Thus, the hemp concrete can play a major role thanks to its positive environmental impact and its hygrothermal properties that allow it to ensure a role of heat damper and comfort stabilizer. Or hygrothermal behavior of hemp concrete throughout the building is little discussed in the literature and never for commercial buildings. The main objective of this project is to fill this gap by studying and optimizing the energy performance of a hemp concrete building designed for offices and / or classrooms. To ensure inside thermal comfort, different technical solutions will be coupled to the building and compared with each other: - A double flow thermodynamical ventilation combining a heat pump with a double flow central. - A simple flow ventilation associated to a pipe system which recovers heat from the basement to preheat ventilation air in winter and cool in the summer. - A double flow ventilation associated to a Canadian well. Through computer simulation and measurements made initially at the level of components, it will be possible to evaluate the potential of each component on the energy and hygrothermal comfort of commercial buildings mainly integrating the project boundary Grand Campus Reims but also can be extended to other French specificity climates.
60

Teplotně vlhkostní namáhaní stěny dřevostavby / Hygrothermal processes in walls of wooden houses

Veselá, Lucie January 2018 (has links)
The diploma thesis deals with the thermal-humidity stress of the wooden wall. The work is focused on the connection of the wall to the base structure of the building. Three details were chosen. The work was focused on detail with the most common structure of an external wall used in the Czech Republic on the composition with a supporting structure made of KVH columns, which are filled with mineral insulation. This construction is covered with plate elements. The insulation from the exterior is made of ETICS with expanded polystyrene thermal insulation. This detail was assessed in the software. To compare the results calculated by real-time software, an experimental model was made, which was subjected to experimental measurements. Part of the diploma thesis is a comparison of detail stress under different boundary design conditions, with or without anchoring.

Page generated in 0.0631 seconds