• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • Tagged with
  • 39
  • 39
  • 23
  • 17
  • 15
  • 14
  • 12
  • 10
  • 10
  • 8
  • 6
  • 6
  • 6
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

\"Estudo prospectivo dos parâmetros periodontais e peri-implantares dos pilares que recebem prótese dento-implanto-suportada\" / Prospective study of periodontal and peri-implant parameters of the pillars receiving an implant supported dental prosthesis

Lima, Vicente José Muratore de 18 September 2006 (has links)
Desde a introdução dos implantes na Odontologia, controvérsias tem havido acerca da propriedade de conectar os implantes a dentes em próteses fixas. Os implantes osseointegrados não apresentam nenhum ligamento periodontal e são mais firmemente ancorados ao osso. A diferença apresentada nesta ancoragem tem levantado preocupações acerca de o implante osseointegrado, por sua firme fixação ao osso, apresentar pouca flexibilidade para dividir as cargas funcionais com os dentes conectados. O presente estudo teve como propósito acompanhar prospectivamente os parâmetros periodontais ? índice gengival, índice de sangramento, profundidade de sondagem e perda de inserção entre o dente pilar de uma prótese dento-implanto-suportada com o dente colateral do mesmo paciente, e também os parâmetros peri-implantares dos implantes que suportam estas próteses - índice gengival; índice de sangramento; profundidade de sondagem e perda de inserção. Para verificar a perda de inserção foi utilizado o recurso da subtração radiográfica da região em que a prótese foi instalada, com tomadas radiográficas efetuadas no momento da instalação da prótese, decorridos seis meses e após 12 meses de uso, com o objetivo de verificar a ocorrência, ou não, de alteração do suporte ósseo peri-implantar. Foram selecionados 12 pacientes com estado de saúde normal, apresentando área posterior de mandíbula edêntula onde estava indicada a reabilitação protética por meio de prótese fixa unindo dente a implante. Estes foram tratados com implante de um estágio de 10 mm padrão da Straumann (ITI), que apresenta um pescoço polido de 2.8mm, onde a porção do implante que permanece intra-óssea apresenta uma superfície tratada, com diâmetro de 4.1mm. O implante foi instalado no espaço onde se localizaria o retentor mais distal da futura prótese parcial fixa, seguindo o protocolo. As radiografias digitais obtidas foram avaliadas num software de subtração radiográfica, Matrox Inspector versão oito, para verificar a alteração da variação de densidade óptica e contraste das radiografias quando superpostas, sendo os valores observados no implante comparados com os critérios de sucessos , amplamente abordados nos estudos verificados. Todos os implantes instalados nos pacientes osseointegraram, não houve registro de alteração óssea ao redor dos mesmos e nos dentes pilares das próteses em avaliações feitas após seis meses e 12 meses. As próteses continuaram clinicamente em excelente estado após 12 meses de avaliação nas análises clínicas e radiográficas. Ainda, de acordo com o teste de Sinais de Postos de ilcoxon, concluiu-se estatisticamente que não houve diferença nos parâmetros peri-implantares de cada paciente durante os períodos analisados (zero, seis meses e 12 meses), bem como quando comparados com os respectivos dentes colaterais. / Since the introduction of implants in Dentistry, controversies have arisen about the possibility of connecting implants to teeth in fixed prostheses. Osseointegrated implants do no present any periodontal ligature and are more firmly anchored to the bone. The difference presented by this type of anchorage has led to some concern about the limited flexibility of the osseointegrated implant to share the functional loads with the connected teeth. This study intended to follow-up prospectively the periodontal parameters bleeding index, probing depth between the pillar tooth of an implant supported prosthesis with one control tooth of the same patient and also the implants that support theses prostheses. That is why subtraction radiography of the region in which the prosthesis was placed was used, with radiographs taken at prosthesis placement, after six months and one year of use to verify if the periimplant osseous support had or had not undergone changes. Twelve patients with normal health conditions were selected who presented a posterior area edentulous jaw where a prosthetic rehabilitation by a fixed prosthesis joining tooth to implant was indicated. Patients were treated with an implant of one stage of 10mm standard Straumann (ITI) with a 2.8 mm polished neck, in which the remaining intraosseous portion of the implant has a treated surface of 4.1 mm diameter. The implant was placed in the space where according to the protocol, the more distal retainer of the future fixed partial prosthesis would be located. Digital radiographs were assessed with a subtraction radiography software Matrox Inspector version eight, to corroborate the change of contrast in the radiographs when superimposed, with values observed in the implant compared with the success criteria , widely mentioned in surveyed studies. All implants placed in patients became osseointegrated. There was no record of bone change around them and in the dental pillars of the prostheses at the one year follow-up. Prostheses continue to be in excellent conditions after the one year follow-up based upon clinical and radiographic analyses. Furthermore, in accordance with the Wilcoxon test of matched pairs and signed rank, it was concluded that there was no statistical difference between each group of each patient during the time period analyzed (baseline and one year) as well as when the pillars were compared to their respective controls.
32

"Biomecânica da transmissão de cargas a implantes unitários em função dos materiais protéticos: análise fotoelástica e dinâmica" / Biomechanics load transmission single implants according to prosthetic materials photoelastic and dinamic analysis

Markarian, Roberto Adrian 13 June 2005 (has links)
Em próteses sobre implantes, o recobrimento oclusal com materiais pouco rígidos como os acrílicos, é por vezes utilizado por supostamente reduzir a carga transmitida ao osso, entretanto não existe um consenso na literatura sobre a sua efetividade. O objetivo deste trabalho foi comparar, por análise fotoelástica e dinâmica, a transmissão de forças após a ação de cargas sobre próteses unitárias sobre implantes em função dos materiais protéticos. Confeccionou-se um modelo em resina fotoelástica com anatomia semelhante à região de pré-molares inferiores, contendo um implante de hexágono interno de 3,75 x 11,5 mm. Foram elaboradas três tipos de próteses em materiais com rigidez decrescente: 1- Metálica (alta rigidez); 2- Resina composta (rigidez moderada), 3- Com um disco de EVA interposto com h=2,5 mm (baixa rigidez). Por meio de um polariscópio circular, observou-se qualitativamente a tensão gerada no modelo durante a aplicação de forças axiais de 100 N, em regime compressivo, sobre cada tipo de prótese. Para a análise dinâmica, realizou-se um modelamento físico de cada um dos três sistemas implante-prótese com modelos de Voigt. A partir daí, uma representação matemática dos sistemas foi deduzida e resolvida, levando em consideração as propriedades mecânicas dos diferentes materiais testados, como o módulo de elasticidade (E), o coeficiente elástico (k) e a constante de amortecimento (c). Para representar uma carga mastigatória fisiológica, foi aplicado um pulso de força senoidal com duração de 0,25 s e intensidade máxima de 100 N, segundo a expressão ()) 8 cos( . 50 50 t t f π −=. Observou-se na análise fotoelástica que após a aplicação de 100N, surgiram tensões na região apical e na cervical dos implantes, com intensidade e localização similares entre os três tipos de prótese. A análise dinâmica mostrou que a força de 100N aplicada na prótese é totalmente transmitida ao implante instantaneamente. Os resultados das análises concordam entre si e mostram que não é possível amortecer as forças mastigatórias por meio dos materiais oclusais. / Less rigid oclusal materials such as acrylic resins are often used in prosthesis over implants because they are supposed to diminish the loads transferred to the bone; however there is no scientific evidence to support this theory. The objective of this work was to compare by photoelastic and dynamic analysis the load transfer after oclusal loads over single prosthesis over implants, varying the oclusal materials. A photoelastic model was created, with an anatomy similar to an inferior premolar region. An internal hexagon implant (3,75 x 11,5 mm) was put in this model. Three different types of prosthesis were constructed with decrescent stiffness: 1- Metallic (higher stiffness); 2- Composite resin (moderate stiffness); 3- With an EVA disc interposed (fewer stiffness). By means of a circular polariscope, the stress generated in the model with a compressive axial load of 100 N, was observed for each prosthesis. For the dynamic analysis, a physical modeling of each implant-prosthesis was carried out with Voigt models. After that, a mathematical representation of the systems was deduced and solved, taking into account the mechanic properties of the different materials, like the elastic modulus (E), the elastic coefficient (k) and the damping constant (c). To represent a physiologic masticatory load, a senoidal force was applied, during 0,25 s and maximum load of 100 N, by the expression ()) 8 cos( . 50 50 t t f π −=. With the photoelastic analysis, it was observed that stresses were generated at the apical and cervical regions of implants, with similar intensity and patterns between the three types of prosthesis. The dynamic analysis, showed that the loads applied over the prosthesis are transferred to the implant instantaneously. The results of both anaylis are in agreement that it is not possible to damp masticatory loads by means of occlusal materials.
33

Estudo de dois sistemas de reabilitação com implantes submetidos à ativação imediata: análise clínica, radiográfica e da estabilidade, por frequência de ressonância / Study of two rehabilitation systems with dental implants submitted to immediate loading: clinical and radiographic evaluations, and stability using resonance frequency analysis

Ayub, Eduardo Antonio 28 August 2007 (has links)
Avaliou-se o comportamento biomecânico, quanto à área de estabilidade protética, extensão de cantilever e estabilidade por análise freqüência de ressonância (AFR); parâmetros clínicos: índice de placa (IP), índice de sangramento (IS), supuração, distância da plataforma do implante-margem da mucosa (DPM), profundidade de sondagem (PS), nível de inserção (NI), sangramento à sondagem (SS), largura (LM), espessura (EM) da mucosa e análise radiográfica, em dois sistemas de reabilitações implanto-suportadas. Foram instalados 104 implantes, submetidos à ativação imediata, em 26 pacientes, divididos em dois grupos: A (n= 16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). As próteses foram instaladas em tempo médio de 32h. (T0), e controles realizados em seis (T6), doze (T12) e 24 meses (T24). Como resultado, a taxa de sucesso foi de 100% para o grupo A e 90% para o grupo B para implantes e próteses. Diferenças significantes (p<0,05) foram apresentadas entre o cantilever posterior 10,96mm e 18,81mm e o braço de resistência (BR) 13,87mm e 5,50mm, respectivamente para os grupos A e B. A área de estabilidade, no grupo A foi de 373,5mm2 e no B de 112,8mm2; a média da AFR (em ISQ) do grupo A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 e do grupo B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, com diferenças (p<0,05) entre os tempos (grupo A) e posição dos implantes (grupo B). O IP no grupo A=1,0 e 0,7; grupo B=0,6 e 0,9, o IS (0,7), supuração (ausente) e SS (presença) no grupo A=50% e 37,9%; grupo B=70,1 e 52,1%, no controle de 12 e 24 meses, não mostraram diferenças estatísticas entre os grupos. As médias (em mm) da LM para o grupo A (2,05 e 2,21) e B (2,29 e 2,40) e EM grupo A (1,53 e 1,56) e B (1,31 e 1,43), DPM do grupo A (2,54e 2,52) e B (0,18mm e -0,12mm), PS grupo A (3,52 e 3,52) e B (3,52 e 4,0), NI grupo A (0,98 e 0,99) e B (3,05 e 3,57) e perda óssea grupo A (0,45mm e 0,23mm ) grupo B(0,66mm e 0,22mm), respectivamente para 12 e 24 meses, apresentaram diferenças estatísticas entre os controles. Concluindo-se que 1- O grupo A apresentou área de estabilidade e extensão de cantilever anterior e posterior, com comportamento biomecânico mais favorável do que no grupo B; 2- A estabilidade primária e secundária (AFR) foi diferente entre os tempos (grupo A) e posição dos implantes (grupo B), mas semelhantes entre os grupos; 3- Os parâmetros clínicos de índice de placa, sangramento marginal, supuração, profundidade de sondagem (exceto para os períodos de controle no grupo B), sangramento a sondagem, largura e espessura de mucosa ceratinizada foram semelhantes entre os grupos; 4- A distância da plataforma do implante-margem da mucosa foi maior no grupo A e o nível de inserção foi maior no grupo B; 5- A perda na altura da crista óssea foi semelhante entre os grupos; 6- A perda óssea foi menor nos implantes anteriores do que nos posteriores, nos grupos. / Two implant-supported rehabilitation systems were evaluated considering their biomechanical behavior, the area of prosthetic stability, cantilever extensions, stability using resonance frequency analysis (RFA) and clinical parameters, such as: modified plaque index (PI), modified bleeding index (BI), suppuration, distance between the implant shoulder and the mucosal margin (DIM), probing pocket depth (PD), probing attachment level (PAL), bleeding on probing (BP), thickness (TM) width (WM) of keratinized mucosa and radiographic analysis. One hundred and four implants had been installed in twenty six patients, submitted to immediate loading and divided into two groups: A (n=16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). The prosthesis had been installed in average time of 32h (T0), and controls made in (T6), 12 (T12) and 24 months (T24). As result, the success rate was 100% for the group A and 90% for the group B for both implants and prosthesis. Significant differences (p<0,05) 10,96mm and 18,81mm had been presented between posterior cantilever and the resistance arm (RA) 13,87mm and 5,50mm, respectively for the groups A and B. The stability area, in the group A was of 373,5mm2 and in B of 112,8mm2; the average of RFA (in ISQ) of the group A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 and of the group B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, with differences (p<0,05) between the periods (Group A) and implant position (Group B). The PI in group A was of 1,0 and 0,7 and 0,6 and 0,9 for group B, o BI (0,7), suppuration (absent), DP (presence) in group A=50% and 37,9%; group B=70,1 and 52,1%, in the control of 12 and 24 months, did not present statistical differences between the groups. The average (in mm) of WM for the group A (2,05 and 2,21) and B (2,29 and 2,40) and TM group A (1,53 and 1,56) and B (1,31 and 1,43), DIM of group A (2,54 and 2,52) and B (0,18mm and -0,12mm), DP group.
34

Avaliação in vitro pelo método DNA-Checkerboard da eficácia de uma pasta antimicrobiana e da adição de sais de prata em pilares protéticos, no controle da contaminação bacteriana através da interface implante-conector / In vitro evaluation by DNA checkerboard method of the efficacy of an antimicrobial paste and addition of silver salts in prosthetic abutments for the control of bacterial contamination at the implant-connector interface

Fernandes, Flávio Henrique Carriço Nogueira 14 November 2012 (has links)
A odontologia reabilitadora moderna preconiza cada vez mais o uso de implantes dentais para a substituição de dentes ausentes. É sabido que micro-organismos presentes na cavidade oral, em especial os relacionados à doença periodontal, são responsáveis pelos maiores índices de insucesso dos implantes. Este trabalho estudou a ocorrência de infiltração bacteriana através da interface implante-conector protético de implantes Cone Morse (CM) e Hexágono Interno (HI) após a associação com uma pasta antimicrobiana ou a adição de sais de prata nos pilares. Foram utilizados 72 implantes odontológicos de titânio (PROSS® - Sistema de Implantes, Dabi-Atlante, Ribeirão Preto, Brasil), 36 com conexão do tipo hexágono interno e 36 com conexão do tipo cone-morse, divididos em grupos, da seguinte forma: Grupo Pasta Antimicrobiana- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos, Grupo Íons de Prata- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos e Grupo Controle- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos. Os implantes e os conectores protéticos foram retirados de suas embalagens para aplicação do torque final (20N/cm). Antes disso, em um dos grupos experimentais, uma camada da pasta antimicrobiana foi aplicada sobre a superfície interna dos implantes e conectores protéticos e seus respectivos parafusos. Os conjuntos implantes-conectores foram parcialmente imersos na solução de saliva humana em tubos de ensaio e incubados em estufa bacteriológica a 37°C durante 7 dias. Após esse período, amostras do conteúdo interno dos conjuntos implantes-conectores protéticos dos 3 grupos foram colhidas com o objetivo de detectar e quantificar os micro-organismos presentes, utilizando para isto, a técnica de hibridização com sondas de DNA genômico DNA Checkerboard. Os implantes de conexão do tipo cone morse apresentaram menores valores de contagem de bactérias quando comparados aos implantes hexágono interno no grupo Controle (p<0,001), já para o grupo Íons de prata e Pasta antimicrobiana, foi observado comportamento inverso, maiores valores de contagem de bactérias para os implantes Cone Morse. Comparando-se os implantes de mesma conexão, entre os 03 grupos examinados, as amostras dos implantes Cone Morse dos grupos Controle, Íons de prata e Pasta antimicrobiana apresentaram valor de contagens de micro-organismos em ordem crescente. Os implantes de conexão hexágonal interna dos grupos Controle apresentaram maiores valores de contagens de micro-organismos seguidos pelos implantes do grupo Pasta antimicrobiana e Íons de prata, respectivamente. A partir dos resultados obtidos pode-se concluir que houve a passagem dos 43 micro-organismos analisados in vitro através da interface implante/componente protético em ambos os sistemas avaliados. Para ambos os tratamentos (adição de sais de prata às paredes dos pilares protéticos e aplicação da pasta antimicrobiana no interior dos implantes) houve diminução da infiltração microbiana no interior daqueles sistemas de conexão do tipo Hexágono Interno. / The contemporary and modern dentistry has been preconized the use of dental implants for replacement of missing teeth. The micro-organisms presents in oral environment, particularly those related to periodontal disease, are responsible for the highest failure rates of dental implants. This study evaluated the occurrence of bacterial leakage through the abutmentimplant interface in Morse Taped (CM) and Hexagon Internal (HI) dental implants after the association with antimicrobial paste or addition of silver salts on the abutments. 72 titanium dental implants (Pross ® - Implant System, Dabi-Atlante, Ribeirão Preto, Brazil), 36 with internal hexagon connection type and 36 with cone-morse connection type, divided into groups as follows: group Antimicrobial Paste -12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors, group Ion Silver-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors and Control Group-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors. The implants and prosthetic connectors have been removed from their packaging for applying of final torque (20N/cm). Previously, in one experimental group, a layer of antimicrobial paste was applied on the inner surface of implants and prosthetic connectors. The sets connector/implants were partially immersed in human saliva solution in test tubes and incubated in bacteriological oven at 37°C for 7 days. Subsequently, samples of the contents of internal prosthetic sets implantconnectors of the 3 groups were collected to detect and quantify micro-organisms, through the DNA Checkerboard Hybridization Technique. The morse taper implants had significantly lower bacterial count compared to internal hexagon implants in the control group (p <0.001), while for the group of Silver Ion and antimicrobial Paste, we observed an inverse behavior, higher counts of micro-organisms for Morse taper implants. Comparing the same connection implants, among the 03 groups examined, samples of implants Morse Taper Control groups, Antimicrobial Paste and Silver ions exhibited values of counts of micro-organisms in ascending order. The internal hexagon implants of the Control group showed higher counts of microorganisms followed by Antimicrobial Paste and Silver Ions groups, respectively. The 43 species analyzed in vitro infiltrated through the interface implant / abutment in both systems evaluated; For both the treatments (adding silver salts in the abutments walls and applying of the antimicrobial paste within the implants) there was decreased microbial leakage through the interface connection for the internal hexagon dental implants
35

Osteointegração da hidroxiapatita sintética no processo alveolar da mandíbula de cães / Synthetic hydroxyapatite osteointegration in the jaw alveolar process of dogs

Duarte, Tatiana Schmitz 22 August 2003 (has links)
Made available in DSpace on 2015-03-26T13:47:25Z (GMT). No. of bitstreams: 1 texto completo.pdf: 444410 bytes, checksum: ae767234a6948287c0570d5341202961 (MD5) Previous issue date: 2003-08-22 / The wear of the alveolar process results in the loss of the tooth and its regeneration is required for the use of dental implant. The objective of this project was to evaluate the synthetic hydroxyapatite as bone substitute in the regeneration of the alveolar process. For that, 28 healthy adult dogs, males and females, weighing between 10 and 15 Kg and divided in two groups were used. Defects of approximately 6 x 5 mm were created in the vestibular surface of the alveolar process until reaching the root of the mandibular right fourth premolar. In a group, the defect was totally filled with synthetic hydroxyapatite while in the other it stayed without treatment, being used as control. The animals were submitted to daily clinical evaluations during one week, as well as radiographic exams just after the surgery and on days 8th, 21st, 42nd, 60th, 90th and 120th of postoperative. Bone fragments were collected eight, 15, 21, 42, 60, 90 and 120 days after surgery for the histological analysis under optical microscopy. Most of the animals presented some degree of inflammation, being the recovery slower in the treated group than in the control one. In 100% of the animals there was bleeding stimulus in the presence of hydroxyapatite. The radiographic exams showed growing radiopacity in the animals of control defect group. In the treated defect group there was initially, superior radiopacity when compared to the normal bone, followed by gradual decrease until becoming similar to the neighbor bone, that happened 60 days after the surgery. Microscopically, bone and vasculars tunnels growth was observed inside the hydroxyapatite pores, as well as an intense osteoblast proliferation and neovascularization in the presence of the implant. The hydroxyapatite biocompatibility allowed its integration with the alveolar process through the direct formation of lamelar bone. Therefore, it happens new bone formation as the hydroxyapatite is degraded. / O desgaste do processo alveolar leva a perda do dente, sendo sua regeneração pré-requisito para o uso de implantes dentários. Com isso, o objetivo deste projeto foi avaliar a hidroxiapatita sintética como substituto ósseo na regeneração do processo alveolar. Para tal, foram utilizados 28 cães adultos, fêmeas e machos sadios, pesando entre 10 e 15 Kg e divididos em dois grupos. Foram criados defeitos de aproximadamente 6 x 5 mm na superfície vestibular do processo alveolar até atingir a raiz do quarto pré-molar mandibular direito. Em um grupo, o defeito foi totalmente preenchido com hidroxiapatita sintética enquanto o outro permaneceu sem tratamento sendo utilizado como controle. Foram feitas avaliações clínicas diariamente durante uma semana, assim como exames radiográficos logo após a cirurgia e com oito, 21, 42, 60, 90 e 120 dias do pós-cirúrgico. Aos oito, 15, 21, 42, 60, 90 e 120 dias foram coletados fragmentos ósseos para a análise histológica sob microscopia óptica. A maioria dos animais apresentou algum grau de inflamação, sendo a recuperação no grupo tratado mais lenta se comparada ao grupo controle e, em 100% dos animais houve estímulo ao sangramento na presença da hidroxiapatita. O exame radiográfico apresentou radiopacidade crescente no defeito dos animais do grupo controle. No grupo tratado houve inicialmente, radiopacidade superior ao osso normal, diminuindo gradualmente até se tornar semelhante ao osso vizinho, o que aconteceu 60 dias após a cirurgia. Histologicamente foi observado crescimento ósseo e túneis vasculares no interior dos poros de hidroxiapatita, assim como uma intensa proliferação de osteoblastos e neovascularização na presença do implante. A biocompatibilidade da hidroxiapatita permitiu a sua integração com o processo alveolar através da formação direta de osso lamelar. Portanto, ocorre formação de novo osso à medida que a hidroxiapatita é degradada.
36

Avaliação in vitro pelo método DNA-Checkerboard da eficácia de uma pasta antimicrobiana e da adição de sais de prata em pilares protéticos, no controle da contaminação bacteriana através da interface implante-conector / In vitro evaluation by DNA checkerboard method of the efficacy of an antimicrobial paste and addition of silver salts in prosthetic abutments for the control of bacterial contamination at the implant-connector interface

Flávio Henrique Carriço Nogueira Fernandes 14 November 2012 (has links)
A odontologia reabilitadora moderna preconiza cada vez mais o uso de implantes dentais para a substituição de dentes ausentes. É sabido que micro-organismos presentes na cavidade oral, em especial os relacionados à doença periodontal, são responsáveis pelos maiores índices de insucesso dos implantes. Este trabalho estudou a ocorrência de infiltração bacteriana através da interface implante-conector protético de implantes Cone Morse (CM) e Hexágono Interno (HI) após a associação com uma pasta antimicrobiana ou a adição de sais de prata nos pilares. Foram utilizados 72 implantes odontológicos de titânio (PROSS® - Sistema de Implantes, Dabi-Atlante, Ribeirão Preto, Brasil), 36 com conexão do tipo hexágono interno e 36 com conexão do tipo cone-morse, divididos em grupos, da seguinte forma: Grupo Pasta Antimicrobiana- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos, Grupo Íons de Prata- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos e Grupo Controle- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos. Os implantes e os conectores protéticos foram retirados de suas embalagens para aplicação do torque final (20N/cm). Antes disso, em um dos grupos experimentais, uma camada da pasta antimicrobiana foi aplicada sobre a superfície interna dos implantes e conectores protéticos e seus respectivos parafusos. Os conjuntos implantes-conectores foram parcialmente imersos na solução de saliva humana em tubos de ensaio e incubados em estufa bacteriológica a 37°C durante 7 dias. Após esse período, amostras do conteúdo interno dos conjuntos implantes-conectores protéticos dos 3 grupos foram colhidas com o objetivo de detectar e quantificar os micro-organismos presentes, utilizando para isto, a técnica de hibridização com sondas de DNA genômico DNA Checkerboard. Os implantes de conexão do tipo cone morse apresentaram menores valores de contagem de bactérias quando comparados aos implantes hexágono interno no grupo Controle (p<0,001), já para o grupo Íons de prata e Pasta antimicrobiana, foi observado comportamento inverso, maiores valores de contagem de bactérias para os implantes Cone Morse. Comparando-se os implantes de mesma conexão, entre os 03 grupos examinados, as amostras dos implantes Cone Morse dos grupos Controle, Íons de prata e Pasta antimicrobiana apresentaram valor de contagens de micro-organismos em ordem crescente. Os implantes de conexão hexágonal interna dos grupos Controle apresentaram maiores valores de contagens de micro-organismos seguidos pelos implantes do grupo Pasta antimicrobiana e Íons de prata, respectivamente. A partir dos resultados obtidos pode-se concluir que houve a passagem dos 43 micro-organismos analisados in vitro através da interface implante/componente protético em ambos os sistemas avaliados. Para ambos os tratamentos (adição de sais de prata às paredes dos pilares protéticos e aplicação da pasta antimicrobiana no interior dos implantes) houve diminução da infiltração microbiana no interior daqueles sistemas de conexão do tipo Hexágono Interno. / The contemporary and modern dentistry has been preconized the use of dental implants for replacement of missing teeth. The micro-organisms presents in oral environment, particularly those related to periodontal disease, are responsible for the highest failure rates of dental implants. This study evaluated the occurrence of bacterial leakage through the abutmentimplant interface in Morse Taped (CM) and Hexagon Internal (HI) dental implants after the association with antimicrobial paste or addition of silver salts on the abutments. 72 titanium dental implants (Pross ® - Implant System, Dabi-Atlante, Ribeirão Preto, Brazil), 36 with internal hexagon connection type and 36 with cone-morse connection type, divided into groups as follows: group Antimicrobial Paste -12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors, group Ion Silver-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors and Control Group-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors. The implants and prosthetic connectors have been removed from their packaging for applying of final torque (20N/cm). Previously, in one experimental group, a layer of antimicrobial paste was applied on the inner surface of implants and prosthetic connectors. The sets connector/implants were partially immersed in human saliva solution in test tubes and incubated in bacteriological oven at 37°C for 7 days. Subsequently, samples of the contents of internal prosthetic sets implantconnectors of the 3 groups were collected to detect and quantify micro-organisms, through the DNA Checkerboard Hybridization Technique. The morse taper implants had significantly lower bacterial count compared to internal hexagon implants in the control group (p <0.001), while for the group of Silver Ion and antimicrobial Paste, we observed an inverse behavior, higher counts of micro-organisms for Morse taper implants. Comparing the same connection implants, among the 03 groups examined, samples of implants Morse Taper Control groups, Antimicrobial Paste and Silver ions exhibited values of counts of micro-organisms in ascending order. The internal hexagon implants of the Control group showed higher counts of microorganisms followed by Antimicrobial Paste and Silver Ions groups, respectively. The 43 species analyzed in vitro infiltrated through the interface implant / abutment in both systems evaluated; For both the treatments (adding silver salts in the abutments walls and applying of the antimicrobial paste within the implants) there was decreased microbial leakage through the interface connection for the internal hexagon dental implants
37

\"Estudo prospectivo dos parâmetros periodontais e peri-implantares dos pilares que recebem prótese dento-implanto-suportada\" / Prospective study of periodontal and peri-implant parameters of the pillars receiving an implant supported dental prosthesis

Vicente José Muratore de Lima 18 September 2006 (has links)
Desde a introdução dos implantes na Odontologia, controvérsias tem havido acerca da propriedade de conectar os implantes a dentes em próteses fixas. Os implantes osseointegrados não apresentam nenhum ligamento periodontal e são mais firmemente ancorados ao osso. A diferença apresentada nesta ancoragem tem levantado preocupações acerca de o implante osseointegrado, por sua firme fixação ao osso, apresentar pouca flexibilidade para dividir as cargas funcionais com os dentes conectados. O presente estudo teve como propósito acompanhar prospectivamente os parâmetros periodontais ? índice gengival, índice de sangramento, profundidade de sondagem e perda de inserção entre o dente pilar de uma prótese dento-implanto-suportada com o dente colateral do mesmo paciente, e também os parâmetros peri-implantares dos implantes que suportam estas próteses - índice gengival; índice de sangramento; profundidade de sondagem e perda de inserção. Para verificar a perda de inserção foi utilizado o recurso da subtração radiográfica da região em que a prótese foi instalada, com tomadas radiográficas efetuadas no momento da instalação da prótese, decorridos seis meses e após 12 meses de uso, com o objetivo de verificar a ocorrência, ou não, de alteração do suporte ósseo peri-implantar. Foram selecionados 12 pacientes com estado de saúde normal, apresentando área posterior de mandíbula edêntula onde estava indicada a reabilitação protética por meio de prótese fixa unindo dente a implante. Estes foram tratados com implante de um estágio de 10 mm padrão da Straumann (ITI), que apresenta um pescoço polido de 2.8mm, onde a porção do implante que permanece intra-óssea apresenta uma superfície tratada, com diâmetro de 4.1mm. O implante foi instalado no espaço onde se localizaria o retentor mais distal da futura prótese parcial fixa, seguindo o protocolo. As radiografias digitais obtidas foram avaliadas num software de subtração radiográfica, Matrox Inspector versão oito, para verificar a alteração da variação de densidade óptica e contraste das radiografias quando superpostas, sendo os valores observados no implante comparados com os critérios de sucessos , amplamente abordados nos estudos verificados. Todos os implantes instalados nos pacientes osseointegraram, não houve registro de alteração óssea ao redor dos mesmos e nos dentes pilares das próteses em avaliações feitas após seis meses e 12 meses. As próteses continuaram clinicamente em excelente estado após 12 meses de avaliação nas análises clínicas e radiográficas. Ainda, de acordo com o teste de Sinais de Postos de ilcoxon, concluiu-se estatisticamente que não houve diferença nos parâmetros peri-implantares de cada paciente durante os períodos analisados (zero, seis meses e 12 meses), bem como quando comparados com os respectivos dentes colaterais. / Since the introduction of implants in Dentistry, controversies have arisen about the possibility of connecting implants to teeth in fixed prostheses. Osseointegrated implants do no present any periodontal ligature and are more firmly anchored to the bone. The difference presented by this type of anchorage has led to some concern about the limited flexibility of the osseointegrated implant to share the functional loads with the connected teeth. This study intended to follow-up prospectively the periodontal parameters bleeding index, probing depth between the pillar tooth of an implant supported prosthesis with one control tooth of the same patient and also the implants that support theses prostheses. That is why subtraction radiography of the region in which the prosthesis was placed was used, with radiographs taken at prosthesis placement, after six months and one year of use to verify if the periimplant osseous support had or had not undergone changes. Twelve patients with normal health conditions were selected who presented a posterior area edentulous jaw where a prosthetic rehabilitation by a fixed prosthesis joining tooth to implant was indicated. Patients were treated with an implant of one stage of 10mm standard Straumann (ITI) with a 2.8 mm polished neck, in which the remaining intraosseous portion of the implant has a treated surface of 4.1 mm diameter. The implant was placed in the space where according to the protocol, the more distal retainer of the future fixed partial prosthesis would be located. Digital radiographs were assessed with a subtraction radiography software Matrox Inspector version eight, to corroborate the change of contrast in the radiographs when superimposed, with values observed in the implant compared with the success criteria , widely mentioned in surveyed studies. All implants placed in patients became osseointegrated. There was no record of bone change around them and in the dental pillars of the prostheses at the one year follow-up. Prostheses continue to be in excellent conditions after the one year follow-up based upon clinical and radiographic analyses. Furthermore, in accordance with the Wilcoxon test of matched pairs and signed rank, it was concluded that there was no statistical difference between each group of each patient during the time period analyzed (baseline and one year) as well as when the pillars were compared to their respective controls.
38

Estudo de dois sistemas de reabilitação com implantes submetidos à ativação imediata: análise clínica, radiográfica e da estabilidade, por frequência de ressonância / Study of two rehabilitation systems with dental implants submitted to immediate loading: clinical and radiographic evaluations, and stability using resonance frequency analysis

Eduardo Antonio Ayub 28 August 2007 (has links)
Avaliou-se o comportamento biomecânico, quanto à área de estabilidade protética, extensão de cantilever e estabilidade por análise freqüência de ressonância (AFR); parâmetros clínicos: índice de placa (IP), índice de sangramento (IS), supuração, distância da plataforma do implante-margem da mucosa (DPM), profundidade de sondagem (PS), nível de inserção (NI), sangramento à sondagem (SS), largura (LM), espessura (EM) da mucosa e análise radiográfica, em dois sistemas de reabilitações implanto-suportadas. Foram instalados 104 implantes, submetidos à ativação imediata, em 26 pacientes, divididos em dois grupos: A (n= 16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). As próteses foram instaladas em tempo médio de 32h. (T0), e controles realizados em seis (T6), doze (T12) e 24 meses (T24). Como resultado, a taxa de sucesso foi de 100% para o grupo A e 90% para o grupo B para implantes e próteses. Diferenças significantes (p<0,05) foram apresentadas entre o cantilever posterior 10,96mm e 18,81mm e o braço de resistência (BR) 13,87mm e 5,50mm, respectivamente para os grupos A e B. A área de estabilidade, no grupo A foi de 373,5mm2 e no B de 112,8mm2; a média da AFR (em ISQ) do grupo A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 e do grupo B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, com diferenças (p<0,05) entre os tempos (grupo A) e posição dos implantes (grupo B). O IP no grupo A=1,0 e 0,7; grupo B=0,6 e 0,9, o IS (0,7), supuração (ausente) e SS (presença) no grupo A=50% e 37,9%; grupo B=70,1 e 52,1%, no controle de 12 e 24 meses, não mostraram diferenças estatísticas entre os grupos. As médias (em mm) da LM para o grupo A (2,05 e 2,21) e B (2,29 e 2,40) e EM grupo A (1,53 e 1,56) e B (1,31 e 1,43), DPM do grupo A (2,54e 2,52) e B (0,18mm e -0,12mm), PS grupo A (3,52 e 3,52) e B (3,52 e 4,0), NI grupo A (0,98 e 0,99) e B (3,05 e 3,57) e perda óssea grupo A (0,45mm e 0,23mm ) grupo B(0,66mm e 0,22mm), respectivamente para 12 e 24 meses, apresentaram diferenças estatísticas entre os controles. Concluindo-se que 1- O grupo A apresentou área de estabilidade e extensão de cantilever anterior e posterior, com comportamento biomecânico mais favorável do que no grupo B; 2- A estabilidade primária e secundária (AFR) foi diferente entre os tempos (grupo A) e posição dos implantes (grupo B), mas semelhantes entre os grupos; 3- Os parâmetros clínicos de índice de placa, sangramento marginal, supuração, profundidade de sondagem (exceto para os períodos de controle no grupo B), sangramento a sondagem, largura e espessura de mucosa ceratinizada foram semelhantes entre os grupos; 4- A distância da plataforma do implante-margem da mucosa foi maior no grupo A e o nível de inserção foi maior no grupo B; 5- A perda na altura da crista óssea foi semelhante entre os grupos; 6- A perda óssea foi menor nos implantes anteriores do que nos posteriores, nos grupos. / Two implant-supported rehabilitation systems were evaluated considering their biomechanical behavior, the area of prosthetic stability, cantilever extensions, stability using resonance frequency analysis (RFA) and clinical parameters, such as: modified plaque index (PI), modified bleeding index (BI), suppuration, distance between the implant shoulder and the mucosal margin (DIM), probing pocket depth (PD), probing attachment level (PAL), bleeding on probing (BP), thickness (TM) width (WM) of keratinized mucosa and radiographic analysis. One hundred and four implants had been installed in twenty six patients, submitted to immediate loading and divided into two groups: A (n=16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). The prosthesis had been installed in average time of 32h (T0), and controls made in (T6), 12 (T12) and 24 months (T24). As result, the success rate was 100% for the group A and 90% for the group B for both implants and prosthesis. Significant differences (p<0,05) 10,96mm and 18,81mm had been presented between posterior cantilever and the resistance arm (RA) 13,87mm and 5,50mm, respectively for the groups A and B. The stability area, in the group A was of 373,5mm2 and in B of 112,8mm2; the average of RFA (in ISQ) of the group A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 and of the group B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, with differences (p<0,05) between the periods (Group A) and implant position (Group B). The PI in group A was of 1,0 and 0,7 and 0,6 and 0,9 for group B, o BI (0,7), suppuration (absent), DP (presence) in group A=50% and 37,9%; group B=70,1 and 52,1%, in the control of 12 and 24 months, did not present statistical differences between the groups. The average (in mm) of WM for the group A (2,05 and 2,21) and B (2,29 and 2,40) and TM group A (1,53 and 1,56) and B (1,31 and 1,43), DIM of group A (2,54 and 2,52) and B (0,18mm and -0,12mm), DP group.
39

"Biomecânica da transmissão de cargas a implantes unitários em função dos materiais protéticos: análise fotoelástica e dinâmica" / Biomechanics load transmission single implants according to prosthetic materials photoelastic and dinamic analysis

Roberto Adrian Markarian 13 June 2005 (has links)
Em próteses sobre implantes, o recobrimento oclusal com materiais pouco rígidos como os acrílicos, é por vezes utilizado por supostamente reduzir a carga transmitida ao osso, entretanto não existe um consenso na literatura sobre a sua efetividade. O objetivo deste trabalho foi comparar, por análise fotoelástica e dinâmica, a transmissão de forças após a ação de cargas sobre próteses unitárias sobre implantes em função dos materiais protéticos. Confeccionou-se um modelo em resina fotoelástica com anatomia semelhante à região de pré-molares inferiores, contendo um implante de hexágono interno de 3,75 x 11,5 mm. Foram elaboradas três tipos de próteses em materiais com rigidez decrescente: 1- Metálica (alta rigidez); 2- Resina composta (rigidez moderada), 3- Com um disco de EVA interposto com h=2,5 mm (baixa rigidez). Por meio de um polariscópio circular, observou-se qualitativamente a tensão gerada no modelo durante a aplicação de forças axiais de 100 N, em regime compressivo, sobre cada tipo de prótese. Para a análise dinâmica, realizou-se um modelamento físico de cada um dos três sistemas implante-prótese com modelos de Voigt. A partir daí, uma representação matemática dos sistemas foi deduzida e resolvida, levando em consideração as propriedades mecânicas dos diferentes materiais testados, como o módulo de elasticidade (E), o coeficiente elástico (k) e a constante de amortecimento (c). Para representar uma carga mastigatória fisiológica, foi aplicado um pulso de força senoidal com duração de 0,25 s e intensidade máxima de 100 N, segundo a expressão ()) 8 cos( . 50 50 t t f &#960; &#8722;=. Observou-se na análise fotoelástica que após a aplicação de 100N, surgiram tensões na região apical e na cervical dos implantes, com intensidade e localização similares entre os três tipos de prótese. A análise dinâmica mostrou que a força de 100N aplicada na prótese é totalmente transmitida ao implante instantaneamente. Os resultados das análises concordam entre si e mostram que não é possível amortecer as forças mastigatórias por meio dos materiais oclusais. / Less rigid oclusal materials such as acrylic resins are often used in prosthesis over implants because they are supposed to diminish the loads transferred to the bone; however there is no scientific evidence to support this theory. The objective of this work was to compare by photoelastic and dynamic analysis the load transfer after oclusal loads over single prosthesis over implants, varying the oclusal materials. A photoelastic model was created, with an anatomy similar to an inferior premolar region. An internal hexagon implant (3,75 x 11,5 mm) was put in this model. Three different types of prosthesis were constructed with decrescent stiffness: 1- Metallic (higher stiffness); 2- Composite resin (moderate stiffness); 3- With an EVA disc interposed (fewer stiffness). By means of a circular polariscope, the stress generated in the model with a compressive axial load of 100 N, was observed for each prosthesis. For the dynamic analysis, a physical modeling of each implant-prosthesis was carried out with Voigt models. After that, a mathematical representation of the systems was deduced and solved, taking into account the mechanic properties of the different materials, like the elastic modulus (E), the elastic coefficient (k) and the damping constant (c). To represent a physiologic masticatory load, a senoidal force was applied, during 0,25 s and maximum load of 100 N, by the expression ()) 8 cos( . 50 50 t t f &#960; &#8722;=. With the photoelastic analysis, it was observed that stresses were generated at the apical and cervical regions of implants, with similar intensity and patterns between the three types of prosthesis. The dynamic analysis, showed that the loads applied over the prosthesis are transferred to the implant instantaneously. The results of both anaylis are in agreement that it is not possible to damp masticatory loads by means of occlusal materials.

Page generated in 0.5053 seconds