1 |
Avaliação de métodos para desinfecção de água, empregando cloro, ácido peracético, ozônio e o processo de desinfecção combinado ozônio/cloro / Methods evaluation for water disinfection using chlorine, peracetic acid, ozone and the ozone/chlorine combined disinfection processSouza, Jeanette Beber de 17 February 2006 (has links)
Foi realizado estudo de desinfecção comparativo, em condições experimentais similares, entre hipoclorito de sódio, ácido peracético, ozônio e o processo de desinfecção seqüencial ozônio/cloro para águas de estudo com características de cor baixa (< 5 uH) e cor elevada (> 100 uH). O desempenho dos desinfetantes foi avaliado segundo a inativação de três microrganismos indicadores, Escherichia coli ATCC 11229, colifagos e Clostridium perfringens ATCC 13124. As concentrações aplicadas de cloro (\'CL IND.2\'), ácido peracético e ozônio (\'O IND.3\') foram de 2,0; 3,0; 4,0 e 5,0 mg/L. A desinfecção seqüencial consistiu das seguintes combinações de concentrações em mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' e 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. Os tempos de contato empregados foram de 5, 10, 15 e 20 minutos, tanto para os ensaios individuais, como para a etapa seqüencial. O cloro livre aplicado foi rapidamente transformado em formas de cloro combinado, nos primeiros 5 minutos de contato, para todas as dosagens aplicadas, diminuindo a ação desinfetante do mesmo. Os resultados dos ensaios de desinfecção com ácido peracético indicaram efetiva redução dos microrganismos indicadores empregados, mesmo na presença de elevada concentração de matéria orgânica, proveniente dos meios de cultura. O ozônio foi considerado efetivo para inativação dos três microrganismos indicadores, apresentando melhores resultados que os demais desinfetantes, na inativação dos fagos. Na etapa da desinfecção seqüencial as inativações de E. coli, colifagos e C. perfringens foram substancialmente superiores às inativações obtidas com ozônio e cloro individuais. Ocorreu sinergismo para E. coli e fagos para todas as dosagens e tempos de contato empregados. Em relação à bactéria esporulada C. perfringens tal fenômeno não foi observado para todos as combinações de ozônio e cloro testadas / This is the result of a comparative disinfection study, performed in similar experimental conditions, among hypochlorite of sodium, peracetic acid, ozone and the ozone/chlorine sequential disinfection process for waters of study with low color (< 5 uH) and high color (> 100 uH) features. The disinfectants performance was evaluated according to the inactivation of three indicators microorganisms: Escherichia coli ATCC 11229, coliphages and Clostridium perfringens ATCC 13124. The applied concentrations of chlorine (\'CL IND.2\'), peracetic acid and ozone (\'O IND.3\') were of 2,0; 3,0; 4,0 and 5,0 mg/L. The sequential disinfection consisted of the following concentrations combinations in mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' and 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. The different times of contact employed were of 5, 10, 15 and 20 minutes, as for the single test, as for the sequential stage. The free chlorine applied was quickly transformed into combined chlorine forms, in the first 5 minutes of contact, for all the dosages applied, reducing its disinfectant action. The disinfection tests results with peracetic acid indicated an effective reduction of the indicators microorganisms employed, even in the presence of a high concentration of organic matters, deriving from the culture medium. The ozone was considered effective for the inactivation of all the three indicators microorganisms, presenting better results than the other disinfectants for the phages inactivation. In the stage of the sequential disinfection, the inactivations of E. coli, coliphages and C. perfringens were remarkably superior to the inactivations obtained with just ozone and chlorine. It occurred synergism to E. coli and phages for all dosages and times of contact employed. Such a phenomenon was not observed in relation to the sporulated bacteria C. perfringens, for all the combinations of ozone and chlorine tested
|
2 |
Avaliação de métodos para desinfecção de água, empregando cloro, ácido peracético, ozônio e o processo de desinfecção combinado ozônio/cloro / Methods evaluation for water disinfection using chlorine, peracetic acid, ozone and the ozone/chlorine combined disinfection processJeanette Beber de Souza 17 February 2006 (has links)
Foi realizado estudo de desinfecção comparativo, em condições experimentais similares, entre hipoclorito de sódio, ácido peracético, ozônio e o processo de desinfecção seqüencial ozônio/cloro para águas de estudo com características de cor baixa (< 5 uH) e cor elevada (> 100 uH). O desempenho dos desinfetantes foi avaliado segundo a inativação de três microrganismos indicadores, Escherichia coli ATCC 11229, colifagos e Clostridium perfringens ATCC 13124. As concentrações aplicadas de cloro (\'CL IND.2\'), ácido peracético e ozônio (\'O IND.3\') foram de 2,0; 3,0; 4,0 e 5,0 mg/L. A desinfecção seqüencial consistiu das seguintes combinações de concentrações em mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' e 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. Os tempos de contato empregados foram de 5, 10, 15 e 20 minutos, tanto para os ensaios individuais, como para a etapa seqüencial. O cloro livre aplicado foi rapidamente transformado em formas de cloro combinado, nos primeiros 5 minutos de contato, para todas as dosagens aplicadas, diminuindo a ação desinfetante do mesmo. Os resultados dos ensaios de desinfecção com ácido peracético indicaram efetiva redução dos microrganismos indicadores empregados, mesmo na presença de elevada concentração de matéria orgânica, proveniente dos meios de cultura. O ozônio foi considerado efetivo para inativação dos três microrganismos indicadores, apresentando melhores resultados que os demais desinfetantes, na inativação dos fagos. Na etapa da desinfecção seqüencial as inativações de E. coli, colifagos e C. perfringens foram substancialmente superiores às inativações obtidas com ozônio e cloro individuais. Ocorreu sinergismo para E. coli e fagos para todas as dosagens e tempos de contato empregados. Em relação à bactéria esporulada C. perfringens tal fenômeno não foi observado para todos as combinações de ozônio e cloro testadas / This is the result of a comparative disinfection study, performed in similar experimental conditions, among hypochlorite of sodium, peracetic acid, ozone and the ozone/chlorine sequential disinfection process for waters of study with low color (< 5 uH) and high color (> 100 uH) features. The disinfectants performance was evaluated according to the inactivation of three indicators microorganisms: Escherichia coli ATCC 11229, coliphages and Clostridium perfringens ATCC 13124. The applied concentrations of chlorine (\'CL IND.2\'), peracetic acid and ozone (\'O IND.3\') were of 2,0; 3,0; 4,0 and 5,0 mg/L. The sequential disinfection consisted of the following concentrations combinations in mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' and 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. The different times of contact employed were of 5, 10, 15 and 20 minutes, as for the single test, as for the sequential stage. The free chlorine applied was quickly transformed into combined chlorine forms, in the first 5 minutes of contact, for all the dosages applied, reducing its disinfectant action. The disinfection tests results with peracetic acid indicated an effective reduction of the indicators microorganisms employed, even in the presence of a high concentration of organic matters, deriving from the culture medium. The ozone was considered effective for the inactivation of all the three indicators microorganisms, presenting better results than the other disinfectants for the phages inactivation. In the stage of the sequential disinfection, the inactivations of E. coli, coliphages and C. perfringens were remarkably superior to the inactivations obtained with just ozone and chlorine. It occurred synergism to E. coli and phages for all dosages and times of contact employed. Such a phenomenon was not observed in relation to the sporulated bacteria C. perfringens, for all the combinations of ozone and chlorine tested
|
3 |
Comparação da resistência de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - e de microrganismos indicadores à desinfecção sequencial cloro-radiação ultravioleta e ozônio-radiação ultravioleta / Comparion of the resistance of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - and indicators microorganisms to sequential disinfection with chlorine-ultraviolet radiation and ozone-ultraviolet radiationMedeiros, Raphael Corrêa 30 April 2010 (has links)
Este trabalho teve por objetivo estudar a desinfecção seqüencial cloro-radiação ultravioleta e ozônio-radiação ultravioleta a fim de avaliar a resistência de microrganismos indicadores de poluição fecal - E. coli, coliformes totais e Clostridium perfringens - e compará-la à dos protozoários patogênicos: Giardia spp. e Cryptosporidium spp.. Houve, primeiramente, monitoramento do reator anaeróbio UASB cujo efluente foi utilizado neste estudo. Foi, então, verificado o comportamento das espécies residuais de cloro no esgoto e conduzido um estudo de parâmetros indicadores (pH, potencial de oxi-redução e condutividade) para o breakpoint. Na desinfecção, foram empregados o cloro, ozônio e radiação ultravioleta; separados, e seqüencialmente. Os ensaios realizados com ozônio promoveram remoção de DQO, sólidos e dos valores de absorbância em 254 nm, diferentemente do cloro. A ordem crescente de resistência à desinfecção foi: E. coli < coliformes totais < C. perfringens < protozoários. Houve correlação em alguns ensaios entre a bactéria esporulada C. perfringens e Giardia spp.. O efeito sinérgico, promovido pela desinfecção seqüencial, foi evidenciado em alguns experimentos para C. perfringens e Giardia spp. / The present dissertation reports on the study of the sequential disinfection with chlorine-ultraviolet radiation and ozone-ultraviolet radiation to evaluate the resistance of microorganisms that indicate fecal pollution - E. coli, total coliforms and Clostridium perfringens - and compare it to the resistance of pathogenic protozoa: Giardia spp. and Cryptosporidium spp.. Firstly, the UASB reactor, whose effluent was utilized in this study, was monitored. Then the behavior of the residual species of chlorine in the sanitary sewage was verified and a study of the indicating parameters (pH, oxi-reduction potential and conductivity) for the breakpoint was conducted. Chlorine, ozone and ultraviolet radiation were used separately and sequentially in the disinfection. Tests performed with ozone promoted removal of COD, solids and absorbance values of 254 nm, differently from chlorine. The order of resistance to disinfection was: E. coli < total coliforms < Clostridium perfringens < protozoa. There was a correlation in some tests between spore-forming bacterium Clostridium perfringens and Giardia spp.. The synergic effect caused by the sequential disinfection was observed in some experiments for C. perfringens and Giardia spp.
|
4 |
Comparação da resistência de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - e de microrganismos indicadores à desinfecção sequencial cloro-radiação ultravioleta e ozônio-radiação ultravioleta / Comparion of the resistance of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - and indicators microorganisms to sequential disinfection with chlorine-ultraviolet radiation and ozone-ultraviolet radiationRaphael Corrêa Medeiros 30 April 2010 (has links)
Este trabalho teve por objetivo estudar a desinfecção seqüencial cloro-radiação ultravioleta e ozônio-radiação ultravioleta a fim de avaliar a resistência de microrganismos indicadores de poluição fecal - E. coli, coliformes totais e Clostridium perfringens - e compará-la à dos protozoários patogênicos: Giardia spp. e Cryptosporidium spp.. Houve, primeiramente, monitoramento do reator anaeróbio UASB cujo efluente foi utilizado neste estudo. Foi, então, verificado o comportamento das espécies residuais de cloro no esgoto e conduzido um estudo de parâmetros indicadores (pH, potencial de oxi-redução e condutividade) para o breakpoint. Na desinfecção, foram empregados o cloro, ozônio e radiação ultravioleta; separados, e seqüencialmente. Os ensaios realizados com ozônio promoveram remoção de DQO, sólidos e dos valores de absorbância em 254 nm, diferentemente do cloro. A ordem crescente de resistência à desinfecção foi: E. coli < coliformes totais < C. perfringens < protozoários. Houve correlação em alguns ensaios entre a bactéria esporulada C. perfringens e Giardia spp.. O efeito sinérgico, promovido pela desinfecção seqüencial, foi evidenciado em alguns experimentos para C. perfringens e Giardia spp. / The present dissertation reports on the study of the sequential disinfection with chlorine-ultraviolet radiation and ozone-ultraviolet radiation to evaluate the resistance of microorganisms that indicate fecal pollution - E. coli, total coliforms and Clostridium perfringens - and compare it to the resistance of pathogenic protozoa: Giardia spp. and Cryptosporidium spp.. Firstly, the UASB reactor, whose effluent was utilized in this study, was monitored. Then the behavior of the residual species of chlorine in the sanitary sewage was verified and a study of the indicating parameters (pH, oxi-reduction potential and conductivity) for the breakpoint was conducted. Chlorine, ozone and ultraviolet radiation were used separately and sequentially in the disinfection. Tests performed with ozone promoted removal of COD, solids and absorbance values of 254 nm, differently from chlorine. The order of resistance to disinfection was: E. coli < total coliforms < Clostridium perfringens < protozoa. There was a correlation in some tests between spore-forming bacterium Clostridium perfringens and Giardia spp.. The synergic effect caused by the sequential disinfection was observed in some experiments for C. perfringens and Giardia spp.
|
Page generated in 0.282 seconds