1

Reúso de água e aquicultura: inativação de fármacos e interferentes endócrinos pelo processo foto-Fenton solar / Water reuse: inactivation of pharmaceuticals and endocrine disruptors by the solar photo-Fenton process

Verdicchio, Letícia 14 July 2017 (has links)
A presença de poluentes em concentrações na faixa de ng L-1 e µg L-1 nos diferentes tipos de água é uma grande preocupação ambiental porque podem apresentar efeitos nocivos aos seres vivos e os sistemas convencionais de tratamento de água e esgoto não são eficientes em removê-los. Os processos oxidativos avançados (POA) são considerados métodos eficazes para a degradação desse tipo de contaminantes e podem ser utilizados para tratar efluentes com a finalidade de reúso em diferentes aplicações como, por exemplo, agricultura ou aquicultura. Assim, o objetivo desta Dissertação foi avaliar a inativação de fármacos e interferentes endócrinos, em um reator tipo coletor parabólico composto, pelo processo foto-Fenton mediado por radiação solar em efluente de estação de tratamento de esgoto. Primeiramente, foi construído o reator, estabelecida a extração em fase sólida como a técnica aplicada para o preparo das amostras a serem analisadas por CLAE/DAD e desenvolvido o método para identificação de sete contaminantes (sulfatiazol, sulfamezarina, sulfadimetoxina, sulfametoxazol, metilparabeno, propilparabeno e naproxeno) no efluente de estação de tratamento de esgoto. Na sequência, foram realizados experimentos com o intuito de otimizar o tratamento e estabeleceram-se as concentrações de H2O2 e ferro (III). Por fim, foram realizados ensaios cinéticos e, adicionalmente, testes ecotoxicológicos para avaliar a ecotoxicidade do efluente antes e depois de 300 min do tratamento foto-Fenton solar. Os resultados mostraram que mesmo após 300 min de reação não houve a completa degradação dos contaminantes, entretanto, o efluente tratado não se mostrou prejudicial aos organismos Daphnia similis e Lactuca sativa. / Currently, the presence of pollutants in concentrations ranging from ng L-1 to µg L-1 in different types of waters constitutes a major environmental concern as they can be harmful to living beings and conventional water and wastewater treatment systems are not efficient in removing them. Advanced oxidation processes are effective methods for the degradation of this type of contaminants and can be applied to wastewater treatments for beneficial water reuse purposes such as agriculture or aquaculture. Thus, the aim of this study was to evaluate the inactivation of some pharmaceuticals and endocrine disruptors, by using a compound parabolic collector reactor, by solar photo-Fenton in municipal wastewater treatment plant effluent. First of all, the reactor was constructed, solid phase extraction (SPE) was determined as the technique used to prepare the samples to be analyzed by HPLC/DAD and the methodology to identify the seven contaminants (sulfathiazole, sulfamerazine, sulfadimethoxine, sulfamethoxazole, methylparaben, propylparaben, and naproxen) in the WWTP effluent was developed. Then, experiments were carried out with the purpose of optimizing the treatment and the concentrations of H2O2 and iron(III) were established. Finally, kinetic tests and, additionally, ecotoxicological assays were carried out to evaluate the effluent ecotoxicity before and after 300 min of the solar photo-Fenton treatment. It has been observed that even after 300 min of reaction there was an incomplete degradation of the pollutants, however, the treated effluent was not harmful to the test-organisms Daphnia similis and Lactuca sativa.
2

Remoção e degradação de alquilbenzeno linear sulfonado de efluente urbano em reator de leito fluidificado em escala piloto / Removal and degradation of sulfonated linear alkylbenzene from urban effluent in pilot scale fluidized bed reactor

Gerosa, Leonardo Emerick 26 September 2017 (has links)
Neste trabalho foi estudada a remoção e degradação de alquilbenzeno linear sulfonado (LAS) em esgoto sanitário afluente da Estação de Tratamento de Esgoto Monjolinho do município de São Carlos-SP. Para isso, foi utilizado reator anaeróbio de leito fluidificado (RALF) em escala piloto com areia como material suporte. O reator foi operado durante 220 dias em TDH de 18±1,96h e temperatura mesófila. Foram realizadas análises físico-químicas e cromatográficas, tanto de caracterização do esgoto sanitário afluente, quanto no monitoramento do reator. Em relação ao esgoto sanitário observou-se 653,50 ± 169,30 mg.L-1 e 6,19 ± 3,25 mg.L -1 para DQO bruta e LAS, respectivamente. Em relação aos metais potencialmente tóxicos foram observados cádmio, chumbo, manganês, níquel e zinco, além de traços de ferro. Em relação aos compostos recalcitrantes foram observados no esgoto sanitário butil benzeno sulfonamida, ácido hexadecanóico, limoneno, terpineno, fenol, álcool feniletílico, indolizina, cafeína e isobutil octadecil ftalato. Durante o período de operação do RALF em fluxo contínuo observou-se 503,84 ± 187,06 mg.L-1 e 210,53 ± 78,37 mg.L -1 de DQO bruta afluente e efluente, respectivamente, e eficiência de remoção de 56 ± 14%. Em relação ao LAS foi observado 7,77 ± 3,06 mg.L-1 e 5,67 ± 2,84 mg.L-1 para o afluente e efluente, respectivamente, e eficiência de remoção de 28 ± 27%. Por meio do balanço de massa foi verificado que apenas 0,1% dessa remoção foi por adsorção. Observou-se pH efluente de 7,40 ± 0,32, alcalinidade total efluente de 233,40 ± 40,75 mgCaCO3 L-1, e ácidos orgânicos voláteis efluente de 57,64 ± 48,08 mg L -1. / In this work, it was studied the removal and degradation of linear alkylbenzene sulfonates (LAS) in a sanitary sewage effluent from the Monjolinho Sewage Treatment Station of the city of São Carlos-SP. For such, it was used a pilot scale anaerobic fluidized bed reactor (AFBR), filled with sand as support material. The reactor was operated with 18 hours of TDH and mesophilic temperature. Physicochemical and chromatographic analyzes were performed both in the characterization of the sewage inflow and in the monitoring of the reactor. The variation in concentration of COD and LAS were of 653,50 ± 169,30 mg L-1, and 6,189 ± 3,25 mg L-1, respectively. Regarding potentially toxic metals, cadmium, lead, manganese, nickel and zinc were observed, traces of Iron were also found. Regarding recalcitrant compounds was observed in sanitary sewage, butyl benzenesulfonamide, hexadecanoic acid, limonene, terpinene, phenol, phenylethyl alcohol, indolizine, caffeine and isobutyl octadecyl phthalate were observed. The AFBR was operated in a continuous stream during 220 days. During this period the COD concentration was 503.84 ± 187.06 mg L-1 and 210.53 ± 78.37 mg L-1, afluente and effluent, respectively, with a removal efficiency of 56 ± 14%. In regard to the surfactant LAS, was observed 7.77 ± 3.06 mg L-1 and 5.67 ± 2.84 mg L-1 a ffluent and effluent respectively, being the efficiency of removal of 28 ± 27%. When the mass balance was perform, it was possible to verify that only 0.1% of this LAS removal was by adsorption. The effluent pH remained stable, close to neutrality 7.40 ± 0.32, the total effluent alkalinity was 233.40 ± 40.75 mgCaCO3 L-1 and volatile organic acids 57.64 ± 48.08 mg L-1.
3

Materiais de tubulações utilizadas em sistemas de coleta e transporte de esgotos sanitários: estudo de caso da área norte de São Paulo. / Pipes materials used in sanitary sewer systems: case study of the northern area of São Paulo.

Bevilacqua, Nelson 06 October 2006 (has links)
Este trabalho descreve os diversos materiais que podem ser utilizados nas tubulações de sistemas de esgotos sanitários, apresenta suas principais características, a hidráulica das tubulações, principais fabricantes, aspectos construtivos, operação e manutenção e comentam-se as normas técnicas referentes a esses materiais. Os dados apresentados foram obtidos através de pesquisa na área norte de São Paulo cujo sistema é operado pela Sabesp, consultando-se as unidades funcionais de projeto, apoio técnico, operação, manutenção e obras da Sabesp. Destaca-se a preferência pelo uso das tubulações de PVC para a implantação e manutenção das ligações prediais e redes coletoras devido às vantagens de sua aplicação, tais como: facilidade de transporte e manuseio, maior produtividade, menos problemas operacionais, praticidade e segurança. Para coletores de maiores diâmetros e interceptores há preferência pelos tubos de PRFV, PVC e PEAD e pelo sistema de tubo de concreto cravado. Na escolha do melhor material a ser utilizado, deve-se considerar além das características dos esgotos, a resistência, a disponibilidade, a facilidade de transporte, e custos desse material . Deve-se, também se levar em conta, o método aplicado na construção e as condições locais da obra. Como principais conclusões, destaca-se a viabilidade econômica da utilização do PVC em relação ao tubo cerâmico nas obras de redes e ligações, e a tendência da utilização de PRFV e PEAD na implantação de novos coletores com diâmetro de 300 a 500mm. Recomenda-se a utilização de juntas elásticas nas tubulações cerâmicas e a especificação do tipo de material precedida de estudos amplos de viabilidade que considerem a sua vida útil, praticidade de aplicação, custos, aspectos ambientais, operação, manutenção, segurança e rapidez na implantação da obra. / This dissertation describes the various materials used in sanitary sewer systems, presents their main characteristics, pipeline hydraulics and manufacturers. It also features construction, operational and maintenance aspects for the different materials as well as the technical regulations concerning these materials. Data were collected in the Northern area of São Paulo, whose sewer system is operated by Sabesp, through research in the following functional units: project, technical support, operations, maintenance and construction. This study highlights the operation area\'s preference for PVC pipes for building and maintenance of sewage connections and sewers because its advantages such as: ease of transportation and handling, greater productivity, less operational problems, practicity and safety. For large diameter trunk sewers and interceptors, FRP (Fiberglass reinforced plastic), PVC (Polyvinyl chloride) and PE (Polyethylene) pipes and Jacking Pipe system are usually the choice. In the selection of the best material, one should consider the wastewater characteristics and the material resistance, availability, ease of transportation and cost. The construction methods and local conditions should also be taken into account in this process. In conclusion, this study stresses the economical viability of PVC pipes over ceramical pipes in sewers and connections, the tendency to use FRP and PE in new 300 - to 500- mm- diameter trunk sewers and recommendation for the use of elastic joints with ceramical pipes. Lastly, the specification of the type of material to be used should be preceded by broad viability studies that consider its required life, practicity, cost, environmental aspects, operational and maintenance aspects and safety in the building process.
4

O índice de diluição de esgoto e o estudo de caso da região metropolitana de São Paulo / The sewage dilution index and the case study of São Paulo\'s metropolitan area

Avila, Rafael Doñate 28 June 2018 (has links)
A implantação e a ampliação dos sistemas de esgotamento sanitário devem contemplar não só aspectos políticos, técnicos e econômicos, mas também sociais, ambientais e de sustentabilidade. Para subsidiar a tomada de decisão com base neste paradigma, e auxiliar na definição das prioridades de intervenções, propõe-se aqui um novo indicador de sustentabilidade, que aqui foi denominado de Índice de Diluição de Esgoto - IDE. Este índice correlaciona a vazão de esgoto sanitário não tratado com a vazão dos corpos d\'água e permite efetuar a avaliar o sistema de esgotamento sob a ótica da capacidade suporte do ambiente. A revisão bibliográfica abordou quatro temas: os esgotos sanitários, os recursos hídricos superficiais, a poluição dos corpos d\'água por esgoto sanitário e os indicadores de sustentabilidade. Com base nos parâmetros de qualidade padrões dos esgotos sanitários e dos corpos d\'água limpos, bem como na legislação ambiental, foram identificadas quatro faixas de risco associadas aos valores do IDE: acima de 0,1% há o risco à saúde e à eutrofização de represas, acima de 5% à comunidade aquática, acima de 10% à harmonia paisagística e acima de 15% à harmonia odorífera. Com o IDE desenvolvido, foi estudado o caso da Região Metropolitana de São Paulo - RMSP: o valor do índice foi calculado para as suas diversas sub-bacias de esgotamento. As bacias com os maiores valores de IDE situam-se em um anel que circunda a RMSP, enquanto que aquelas com os menores valores, nas porções interna e externa deste anel. Poucas sub-bacias apresentaram valores inferior a 0,1% e muitas apresentaram valores acima de 15%, que extrapola os 200% em alguns casos. O estudo da RMSP foi realizado à luz de variáveis territoriais e socioeconômicas, o que propiciou uma discussão do diagnóstico e do planejamento do sistema de esgotamento sob a ótica da sustentabilidade e dos riscos associados. / The implementation and expansion of sewage systems should include not only political, technical and economic aspects, but also social, environmental and sustainability aspects. In order to support decision-making based on this paradigm and to endorse the interventions\'s priorities selection, a new sustainability indicator is proposed here, which has been called Sewage Dilution Index - SDI. This index correlates untreated sanitary sewage flow with the water bodies flow and allows the evaluation of the sewage system from the perspective of environmental support capacity. The literature review addressed four themes: sanitary sewage, surface water resources, pollution of water bodies by sanitary sewage and sustainability indicators. Based on the sanitary sewers and clean water bodies quality parameters standard, as well as environmental legislation, four risk ranges were identified associated with SDI values: above 0.1% a health and reservoir eutrophication risk was identified, above 5% an aquatic community risk, above 10% a landscape harmony risk and above 15% an odoriferous harmony risk. After the SDI was developed, it was accomplished the São Paulo\'s Metropolitan Area - SPRA case study: the sewage\'s índex values was calculated for it\'s sewage\'s sub-basins. The sub-basins with the highest values of SDI are located in a ring that surrounds the SPRA, whereas those with the lowest values are located inside and outside of this ring. Few sub-basins presented values below 0,1% and many showed values above 15%, which exceeds 200% in some cases. The SPRA case study was accomplished associated with territorial and socioeconomic variables, which allowed a discussion of the diagnosis and planning of the sewage system from the sustainability and associated risks point of view.
5

O índice de diluição de esgoto e o estudo de caso da região metropolitana de São Paulo / The sewage dilution index and the case study of São Paulo\'s metropolitan area

Rafael Doñate Avila 28 June 2018 (has links)
A implantação e a ampliação dos sistemas de esgotamento sanitário devem contemplar não só aspectos políticos, técnicos e econômicos, mas também sociais, ambientais e de sustentabilidade. Para subsidiar a tomada de decisão com base neste paradigma, e auxiliar na definição das prioridades de intervenções, propõe-se aqui um novo indicador de sustentabilidade, que aqui foi denominado de Índice de Diluição de Esgoto - IDE. Este índice correlaciona a vazão de esgoto sanitário não tratado com a vazão dos corpos d\'água e permite efetuar a avaliar o sistema de esgotamento sob a ótica da capacidade suporte do ambiente. A revisão bibliográfica abordou quatro temas: os esgotos sanitários, os recursos hídricos superficiais, a poluição dos corpos d\'água por esgoto sanitário e os indicadores de sustentabilidade. Com base nos parâmetros de qualidade padrões dos esgotos sanitários e dos corpos d\'água limpos, bem como na legislação ambiental, foram identificadas quatro faixas de risco associadas aos valores do IDE: acima de 0,1% há o risco à saúde e à eutrofização de represas, acima de 5% à comunidade aquática, acima de 10% à harmonia paisagística e acima de 15% à harmonia odorífera. Com o IDE desenvolvido, foi estudado o caso da Região Metropolitana de São Paulo - RMSP: o valor do índice foi calculado para as suas diversas sub-bacias de esgotamento. As bacias com os maiores valores de IDE situam-se em um anel que circunda a RMSP, enquanto que aquelas com os menores valores, nas porções interna e externa deste anel. Poucas sub-bacias apresentaram valores inferior a 0,1% e muitas apresentaram valores acima de 15%, que extrapola os 200% em alguns casos. O estudo da RMSP foi realizado à luz de variáveis territoriais e socioeconômicas, o que propiciou uma discussão do diagnóstico e do planejamento do sistema de esgotamento sob a ótica da sustentabilidade e dos riscos associados. / The implementation and expansion of sewage systems should include not only political, technical and economic aspects, but also social, environmental and sustainability aspects. In order to support decision-making based on this paradigm and to endorse the interventions\'s priorities selection, a new sustainability indicator is proposed here, which has been called Sewage Dilution Index - SDI. This index correlates untreated sanitary sewage flow with the water bodies flow and allows the evaluation of the sewage system from the perspective of environmental support capacity. The literature review addressed four themes: sanitary sewage, surface water resources, pollution of water bodies by sanitary sewage and sustainability indicators. Based on the sanitary sewers and clean water bodies quality parameters standard, as well as environmental legislation, four risk ranges were identified associated with SDI values: above 0.1% a health and reservoir eutrophication risk was identified, above 5% an aquatic community risk, above 10% a landscape harmony risk and above 15% an odoriferous harmony risk. After the SDI was developed, it was accomplished the São Paulo\'s Metropolitan Area - SPRA case study: the sewage\'s índex values was calculated for it\'s sewage\'s sub-basins. The sub-basins with the highest values of SDI are located in a ring that surrounds the SPRA, whereas those with the lowest values are located inside and outside of this ring. Few sub-basins presented values below 0,1% and many showed values above 15%, which exceeds 200% in some cases. The SPRA case study was accomplished associated with territorial and socioeconomic variables, which allowed a discussion of the diagnosis and planning of the sewage system from the sustainability and associated risks point of view.
6

Reúso de água e aquicultura: inativação de fármacos e interferentes endócrinos pelo processo foto-Fenton solar / Water reuse: inactivation of pharmaceuticals and endocrine disruptors by the solar photo-Fenton process

Letícia Verdicchio 14 July 2017 (has links)
A presença de poluentes em concentrações na faixa de ng L-1 e µg L-1 nos diferentes tipos de água é uma grande preocupação ambiental porque podem apresentar efeitos nocivos aos seres vivos e os sistemas convencionais de tratamento de água e esgoto não são eficientes em removê-los. Os processos oxidativos avançados (POA) são considerados métodos eficazes para a degradação desse tipo de contaminantes e podem ser utilizados para tratar efluentes com a finalidade de reúso em diferentes aplicações como, por exemplo, agricultura ou aquicultura. Assim, o objetivo desta Dissertação foi avaliar a inativação de fármacos e interferentes endócrinos, em um reator tipo coletor parabólico composto, pelo processo foto-Fenton mediado por radiação solar em efluente de estação de tratamento de esgoto. Primeiramente, foi construído o reator, estabelecida a extração em fase sólida como a técnica aplicada para o preparo das amostras a serem analisadas por CLAE/DAD e desenvolvido o método para identificação de sete contaminantes (sulfatiazol, sulfamezarina, sulfadimetoxina, sulfametoxazol, metilparabeno, propilparabeno e naproxeno) no efluente de estação de tratamento de esgoto. Na sequência, foram realizados experimentos com o intuito de otimizar o tratamento e estabeleceram-se as concentrações de H2O2 e ferro (III). Por fim, foram realizados ensaios cinéticos e, adicionalmente, testes ecotoxicológicos para avaliar a ecotoxicidade do efluente antes e depois de 300 min do tratamento foto-Fenton solar. Os resultados mostraram que mesmo após 300 min de reação não houve a completa degradação dos contaminantes, entretanto, o efluente tratado não se mostrou prejudicial aos organismos Daphnia similis e Lactuca sativa. / Currently, the presence of pollutants in concentrations ranging from ng L-1 to µg L-1 in different types of waters constitutes a major environmental concern as they can be harmful to living beings and conventional water and wastewater treatment systems are not efficient in removing them. Advanced oxidation processes are effective methods for the degradation of this type of contaminants and can be applied to wastewater treatments for beneficial water reuse purposes such as agriculture or aquaculture. Thus, the aim of this study was to evaluate the inactivation of some pharmaceuticals and endocrine disruptors, by using a compound parabolic collector reactor, by solar photo-Fenton in municipal wastewater treatment plant effluent. First of all, the reactor was constructed, solid phase extraction (SPE) was determined as the technique used to prepare the samples to be analyzed by HPLC/DAD and the methodology to identify the seven contaminants (sulfathiazole, sulfamerazine, sulfadimethoxine, sulfamethoxazole, methylparaben, propylparaben, and naproxen) in the WWTP effluent was developed. Then, experiments were carried out with the purpose of optimizing the treatment and the concentrations of H2O2 and iron(III) were established. Finally, kinetic tests and, additionally, ecotoxicological assays were carried out to evaluate the effluent ecotoxicity before and after 300 min of the solar photo-Fenton treatment. It has been observed that even after 300 min of reaction there was an incomplete degradation of the pollutants, however, the treated effluent was not harmful to the test-organisms Daphnia similis and Lactuca sativa.
7

Desempenho hidráulico de unidades gotejadoras com efluente doméstico tratado e prevenção do entupimento

Silva, Ketson Bruno da 16 February 2017 (has links)
Submitted by Lara Oliveira (lara@ufersa.edu.br) on 2017-05-18T23:33:39Z No. of bitstreams: 1 KetsonBS_TESE.pdf: 1539822 bytes, checksum: 0c6b1fa96adda03092cd26468cf142d3 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2017-05-24T11:15:41Z (GMT) No. of bitstreams: 1 KetsonBS_TESE.pdf: 1539822 bytes, checksum: 0c6b1fa96adda03092cd26468cf142d3 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2017-05-24T11:15:59Z (GMT) No. of bitstreams: 1 KetsonBS_TESE.pdf: 1539822 bytes, checksum: 0c6b1fa96adda03092cd26468cf142d3 (MD5) / Made available in DSpace on 2017-05-24T11:16:28Z (GMT). No. of bitstreams: 1 KetsonBS_TESE.pdf: 1539822 bytes, checksum: 0c6b1fa96adda03092cd26468cf142d3 (MD5) Previous issue date: 2017-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Brazil faces typical problems of a developing society in relation to water scarcity. This situation intensifies in the northeast region, due to its climate and the lower incidence of rainfall. Reusing water is a way to control losses and avoid waste. Their reuse in agriculture can be a very effective strategy for preserving water resources and reducing their indiscriminate use. An alternative to reduce the risks of contamination of agricultural crops is the use of drip irrigation systems. In this context, the present work had as objective to study the hydraulic performance of dripping units with treated domestic effluent and prevention of clogging. Two experimental stands were set up in an area located in the East Campus of the Universidade Federal Rural do Semi – Árido, Mossoró/RN, to evaluate the hydraulic performance and clogging of four types of drippers every 80 h, applying treated domestic wastewater (ARDT), For a total of 400 hours. The experiment was set up in a sub - divided plots scheme, with treatments: T1 - without application of the product, T2 - 100ml of Byosol Swift in 50L of water, T3 - 200ml of Byosol Swift in 50L of water, and T4 - 300ml of Byosol Swift in 50L of water. In the subplots the types of drippers: G1 - flow of 1,60 L h-1, G2 - flow of 2.00 L h-1, G3 - flow of 1,60 L h-1, and G4 - 70 L h-1, and in the subsubparcels the evaluation periods: 0, 80, 160, 240, 360 and 400 h. At each time, physical-chemical and microbiological analyzes of treated domestic wastewater were also carried out. Data were submitted to simple and multiple regression analysis, mean test and Pearson parametric correlation test. The results indicated that the null (mean), cubic, quadratic and linear regression models were the ones that best fit the analyzed variables, depending on the dosages of the product. The elements Fe, SD, SS, Ca2+ and pH predominated in the empirical models of hydraulic performance for the four types of drippers. There was no difference between treatments. The changes in the analyzed variables were due to the time of operation and the physical-chemical agents, which caused partial clogging of the drippers and, consequently, increase in the coefficients of variation of the flow of the drippers in the irrigation units that operated with ARDT. The action of the enzymatic catalyst was inhibited due to the high chlorine content present in the ARDT. The chemical elements, chlorine, potassium, calcium, silicon, iron and sulfur predominated in the chemical composition of the biofouling present in the analyzed drippers. The service pressures verified upstream and downstream of the screen filter of the irrigation system have inverse behavior over time / O Brasil enfrenta problemas típicos de uma sociedade em desenvolvimento com relação à escassez hídrica. Esta situação se intensifica na região nordeste, devido ao seu clima e as menores incidências de precipitações pluviométricas. Reutilizar a água é uma forma de controlar perdas e evitar desperdícios. Seu reúso na agricultura, pode ser uma estratégia bastante eficaz para preservar os recursos hídricos e diminuir sua utilização indiscriminada. Uma alternativa para reduzir os riscos de contaminação dos cultivos agrícolas é a utilização de sistemas de irrigação por gotejamento. Neste contexto, o presente trabalho teve como objetivo estudar o desempenho hidráulico de unidades gotejadoras com efluente doméstico tratado e prevenção do entupimento. Foram montadas duas bancadas experimentais em área localizada no Campus Leste da Universidade Federal Rural do Semi – Árido, Mossoró/RN, para avaliação, a cada 80h, do desempenho hidráulico e do entupimento de quatro tipos de gotejadores, aplicando água residuária doméstica tratada (ARDT), perfazendo um total de 400h. O experimento foi montado em esquema de parcelas subsubdivididas, tendo nas parcelas os tratamentos: T1 – sem aplicação do produto, T2 – 100ml de Byosol Swift em 50L de água, T3 – 200ml de Byosol Swift em 50L de água, e T4 – 300ml de Byosol Swift em 50L de água. Nas subparcelas os tipos de gotejadores: G1 – vazão de 1,60 L h-1, G2 – vazão de 2,00 L h-1, G3 – vazão de 1,60 L h-1, e G4 – vazão de 1,70 L h-1, e nas subsubparcelas os períodos das avaliações: 0, 80, 160, 240, 360 e 400 h. Em cada tempo, também foram feitas análises físico-químicas e microbiológicas da água residuária doméstica tratada. Os dados foram submetidos às análises de regressão simples e múltipla, teste de média e teste de correlações paramétricas de Pearson. Os resultados indicaram que os modelos de regressão nulo (média), cúbico, quadrático e linear, foram os que melhor se ajustaram às variáveis analisadas, em função das dosagens do produto. Os elementos Fe, SD, SS, Ca2+ e pH predominaram nos modelos empíricos de desempenho hidráulico para os quatro tipos de gotejadores. Não houve diferença entre os tratamentos. As alterações nas variáveis analisadas se deram em função do tempo de operação e dos agentes físico-químicos, que propiciaram entupimento parcial dos gotejadores e, consequentemente, aumento nos coeficientes de variação da vazão dos gotejadores nas unidades de irrigação que operaram com ARDT. A ação do catalisador enzimático foi inibida devido ao alto teor de cloro presente na ARDT. Os elementos químicos, cloro, potássio, cálcio, silício, ferro e enxofre predominaram na composição química da bioincrustação presente nos gotejadores analisados. As pressões de serviço verificadas a montante e a jusante do filtro de tela do sistema de irrigação, apresentam comportamentos inversos ao longo do tempo / 2017-05-18
8

Influência da morfologia e demografia urbana sobre o uso de energia elétrica em sistemas de saneamento : um estudo na região metropolitana do Vale do Paraíba e Litoral Norte do estado de São Paulo / Influence of morphology and urban demographics on the use of electricity in sanitation systems: a study in the metropolitan region of the Paraíba Valley and North Coast of São Paulo

Silva, William Teodoro da [UNESP] 04 August 2016 (has links)
Submitted by WILLIAM TEODORO DA SILVA null (williamteodoroarq@terra.com.br) on 2016-09-05T17:34:14Z No. of bitstreams: 1 Dissertação William Teodoro 05 set 16.pdf: 29727684 bytes, checksum: 563d2b5195d5fd13bc7d23f0ca09bf28 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-09-08T20:29:32Z (GMT) No. of bitstreams: 1 silva_wtt_me_guara.pdf: 29727684 bytes, checksum: 563d2b5195d5fd13bc7d23f0ca09bf28 (MD5) / Made available in DSpace on 2016-09-08T20:29:32Z (GMT). No. of bitstreams: 1 silva_wtt_me_guara.pdf: 29727684 bytes, checksum: 563d2b5195d5fd13bc7d23f0ca09bf28 (MD5) Previous issue date: 2016-08-04 / O crescimento urbano descontrolado gera uma série de problemas como a favelização, a ocupação de áreas irregulares e a quebra do planejamento socioeconômico do município. Além disso, sempre que surge uma comunidade ou uma zona industrial sem planejamento, o poder público deve levar toda infraestrutura urbana para o local. Sendo o saneamento e o fornecimento de energia aspectos fundamentais para a sustentabilidade de cidades, identificase a necessidade de se entender as relações entre desenvolvimento e planejamento urbano e o uso de energia elétrica. Nesse sentido, o presente trabalho propõe-se a estudar as relações entre morfologia urbana e demografia e uso de energia elétrica no setor de saneamento, mais especificamente, para o abastecimento de água e esgotamento sanitário. Para a análise da influência da morfologia e demografia urbana sobre o uso de energia elétrica em sistemas de saneamento através de um estudo na Região Metropolitana do Vale do Paraíba e Litoral Norte do estado de São Paulo foram identificados 10 indicadores, dentre eles 3 morfométricos (Relação de Forma, Relação de Compacidade e Relação de Alongamento), 3 demográficos (Densidade de População Urbana, Densidade de Emprego nos Centros Urbanos e Índice de Distribuição de Domicílios) e 4 energéticos (Consumo Total de Energia Elétrica nos Sistemas de Água, Consumo Total de Energia Elétrica nos Sistemas de Esgoto, Índice de Consumo de Energia Elétrica em Sistemas de Abastecimento de Água e Índice de Consumo de energia elétrica em sistemas de Esgotamento sanitário). Através da correlação de cada indicador morfométrico e demográfico com os índices de consumo de energia elétrica (água e esgoto), foi possível identificar até que ponto essa influência pode ser confirmada. / The uncontrolled urban growth raises a series of problems such as slum, irregular areas, occupation and the breakdown of social and economic planning. In addition, whenever a community or an industrial area without planning, the Government should take all urban infrastructure for the site. Being the sanitation and the power supply fundamental aspects for sustainability, identifies the need to understand the relationships between urban development and planning and the use of electric energy. In this sense, the present work is proposed to study the relations between morphology and urban demographics and usage of electrical energy in the sanitation sector, more specifically, to the water supply and sanitation. For the analysis of the influence of morphology and urban demographics about the use of electricity in sanitation systems through a study on the metropolitan region of the Paraíba Valley and Northern coast of São Paulo 10 indicators were identified, including morphometric 3 (Shape, Compactness and stretching), 3 (demographic density of urban population , Density of employment in Urban Centers and Density index of households) and energy 4 (Total consumption of Electric Energy in water Systems, Total Electric Power Consumption in sewer Systems, electric power Consumption index in water supply systems and electric energy consumption index in sewage supply systems). Through the correlation of morphometric and demographic indicator each with the indexes of electric power consumption (water and sewer), it was possible to identify the extent to which this influence can be confirmed.
9

Materiais de tubulações utilizadas em sistemas de coleta e transporte de esgotos sanitários: estudo de caso da área norte de São Paulo. / Pipes materials used in sanitary sewer systems: case study of the northern area of São Paulo.

Nelson Bevilacqua 06 October 2006 (has links)
Este trabalho descreve os diversos materiais que podem ser utilizados nas tubulações de sistemas de esgotos sanitários, apresenta suas principais características, a hidráulica das tubulações, principais fabricantes, aspectos construtivos, operação e manutenção e comentam-se as normas técnicas referentes a esses materiais. Os dados apresentados foram obtidos através de pesquisa na área norte de São Paulo cujo sistema é operado pela Sabesp, consultando-se as unidades funcionais de projeto, apoio técnico, operação, manutenção e obras da Sabesp. Destaca-se a preferência pelo uso das tubulações de PVC para a implantação e manutenção das ligações prediais e redes coletoras devido às vantagens de sua aplicação, tais como: facilidade de transporte e manuseio, maior produtividade, menos problemas operacionais, praticidade e segurança. Para coletores de maiores diâmetros e interceptores há preferência pelos tubos de PRFV, PVC e PEAD e pelo sistema de tubo de concreto cravado. Na escolha do melhor material a ser utilizado, deve-se considerar além das características dos esgotos, a resistência, a disponibilidade, a facilidade de transporte, e custos desse material . Deve-se, também se levar em conta, o método aplicado na construção e as condições locais da obra. Como principais conclusões, destaca-se a viabilidade econômica da utilização do PVC em relação ao tubo cerâmico nas obras de redes e ligações, e a tendência da utilização de PRFV e PEAD na implantação de novos coletores com diâmetro de 300 a 500mm. Recomenda-se a utilização de juntas elásticas nas tubulações cerâmicas e a especificação do tipo de material precedida de estudos amplos de viabilidade que considerem a sua vida útil, praticidade de aplicação, custos, aspectos ambientais, operação, manutenção, segurança e rapidez na implantação da obra. / This dissertation describes the various materials used in sanitary sewer systems, presents their main characteristics, pipeline hydraulics and manufacturers. It also features construction, operational and maintenance aspects for the different materials as well as the technical regulations concerning these materials. Data were collected in the Northern area of São Paulo, whose sewer system is operated by Sabesp, through research in the following functional units: project, technical support, operations, maintenance and construction. This study highlights the operation area\'s preference for PVC pipes for building and maintenance of sewage connections and sewers because its advantages such as: ease of transportation and handling, greater productivity, less operational problems, practicity and safety. For large diameter trunk sewers and interceptors, FRP (Fiberglass reinforced plastic), PVC (Polyvinyl chloride) and PE (Polyethylene) pipes and Jacking Pipe system are usually the choice. In the selection of the best material, one should consider the wastewater characteristics and the material resistance, availability, ease of transportation and cost. The construction methods and local conditions should also be taken into account in this process. In conclusion, this study stresses the economical viability of PVC pipes over ceramical pipes in sewers and connections, the tendency to use FRP and PE in new 300 - to 500- mm- diameter trunk sewers and recommendation for the use of elastic joints with ceramical pipes. Lastly, the specification of the type of material to be used should be preceded by broad viability studies that consider its required life, practicity, cost, environmental aspects, operational and maintenance aspects and safety in the building process.
10

Tratamento de esgotos sanitarios visando reuso / Sewage treatment for water reuse

Pohlmann, Marcelo 15 August 2018 (has links)
Orientador: Jose Euclides Stipp Paterniani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-15T15:37:50Z (GMT). No. of bitstreams: 1 Pohlmann_Marcelo_D.pdf: 1072862 bytes, checksum: 0fa3511a2a3a2e3add69e9751da2f089 (MD5) Previous issue date: 2010 / Resumo: As perspectivas de escassez de água, em quantidade e qualidade, aliado ao aumento de seu custo vem motivando um número crescente de pesquisas sobre a reutilização dos efluentes tratados onde o requisito de potabilidade não é necessário. A presente pesquisa teve por objetivo avaliar os resultados obtidos de uma estação para tratamento dos esgotos sanitários visando reúso constituída em seqüência por: reator anóxico, valo de oxidação, decantador, filtro biológico, tanque de re-aeração, pré-filtração ascendente, filtração lenta, desinfecção por UV e cloração em linha. A pesquisa foi conduzida por 9 meses (out/08 a jun/09) e os resultados obtidos pelo sistema de tratamento alcançaram as seguintes remoções médias: 94% de sólidos suspensos totais, 96,4% de DBO, 97,5% de DQO e 99% de cor aparente. Os valores dos parâmetros de óleos e graxas, nitrogênio amoniacal e compostos orgânicos voláteis no efluente final ficaram abaixo do limite de quantificação do método de análise. A contagem de coliformes totais e E.coli foi reduzida para 17,4 NMP/100mL e 1,54 NMP/100mL, respectivamente, após a desinfecção por radiação ultravioleta. Os valores obtidos para turbidez (0,92 NTU) e oxigênio dissolvido (5,16 mg/L) na água de reúso atingiram valores similares aos obtidos na água potável da torneira, que apresentou turbidez de 0,35 NTU e oxigênio dissolvido de 5,23 mg/L. O resultado da cor aparente na água de reúso ficou na média em 25 UH, e foi percebido pelos usuários pelo fato das bacias sanitárias serem brancas. A dosagem de hipoclorito de sódio na rede de distribuição se mostrou importante na redução da cor aparente, todavia os resultados variaram de 19 a 95%, evidenciando maior necessidade de controle nesta etapa. Ao final do período avaliado elaborou-se uma proposição de valores para água de reúso em descargas de vasos sanitários / Abstract: The worldwide water scarcity, in quantity as well as in quality, tied to the mounting costs of getting it, has triggered a growing number of studies on the proper utilization of the treated effluent, avoiding the utilization of drinking water in uses where the drinkable standards are not required. The objective of this study was to elaborate a project of a wastewater treatment plant and to evaluate the results obtained on the reutilization of the treated sanitary sewage. The treatment units are: anoxic reactor, oxidation ditch, secondary clarifier, biological filter, re-oxygenation tank, up flow filter, slow filter, UV disinfection and application of chlorine in line. The research was carried out during a period of 9 months (oct/08 to jun/09). The results indicated an average removal up to 94% of total suspended solids, 96,4% of BOD, 97,5% of COD and 99% of color. The analysis of FOG, ammonia nitrogen, volatile organic compounds didn't reach the method limits. The counting for total coliforms reached 17,4 NMP/100mL and 1,54 NMP/100mL fo E.coli after disinfection per UV reactor. The results obtained for turbidity (0,92 NTU) and dissolved oxygen (5,16 mg/L) where similar for the obtained values on the drinkable water that showed turbidity of 0,35 NTU and dissolved oxygen of 5,23 mg/L. The average of the results of color on the water for reuse was 25 UH, and was perceived by the users due to the white toilet basins. The application of chlorine in line on the distribution of the water for reuse was an important factor for color reduction, but the results ranged from 19 to 95% of color removal, indicating the need of better control in this step. At the end of the study it is presented a proposal for a new set of standards for the water reutilization to flush toilet basins / Doutorado / Saneamento e Ambiente / Doutor em Engenharia Civil