• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tratamento de esgotos sanitarios visando reuso / Sewage treatment for water reuse

Pohlmann, Marcelo 15 August 2018 (has links)
Orientador: Jose Euclides Stipp Paterniani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-15T15:37:50Z (GMT). No. of bitstreams: 1 Pohlmann_Marcelo_D.pdf: 1072862 bytes, checksum: 0fa3511a2a3a2e3add69e9751da2f089 (MD5) Previous issue date: 2010 / Resumo: As perspectivas de escassez de água, em quantidade e qualidade, aliado ao aumento de seu custo vem motivando um número crescente de pesquisas sobre a reutilização dos efluentes tratados onde o requisito de potabilidade não é necessário. A presente pesquisa teve por objetivo avaliar os resultados obtidos de uma estação para tratamento dos esgotos sanitários visando reúso constituída em seqüência por: reator anóxico, valo de oxidação, decantador, filtro biológico, tanque de re-aeração, pré-filtração ascendente, filtração lenta, desinfecção por UV e cloração em linha. A pesquisa foi conduzida por 9 meses (out/08 a jun/09) e os resultados obtidos pelo sistema de tratamento alcançaram as seguintes remoções médias: 94% de sólidos suspensos totais, 96,4% de DBO, 97,5% de DQO e 99% de cor aparente. Os valores dos parâmetros de óleos e graxas, nitrogênio amoniacal e compostos orgânicos voláteis no efluente final ficaram abaixo do limite de quantificação do método de análise. A contagem de coliformes totais e E.coli foi reduzida para 17,4 NMP/100mL e 1,54 NMP/100mL, respectivamente, após a desinfecção por radiação ultravioleta. Os valores obtidos para turbidez (0,92 NTU) e oxigênio dissolvido (5,16 mg/L) na água de reúso atingiram valores similares aos obtidos na água potável da torneira, que apresentou turbidez de 0,35 NTU e oxigênio dissolvido de 5,23 mg/L. O resultado da cor aparente na água de reúso ficou na média em 25 UH, e foi percebido pelos usuários pelo fato das bacias sanitárias serem brancas. A dosagem de hipoclorito de sódio na rede de distribuição se mostrou importante na redução da cor aparente, todavia os resultados variaram de 19 a 95%, evidenciando maior necessidade de controle nesta etapa. Ao final do período avaliado elaborou-se uma proposição de valores para água de reúso em descargas de vasos sanitários / Abstract: The worldwide water scarcity, in quantity as well as in quality, tied to the mounting costs of getting it, has triggered a growing number of studies on the proper utilization of the treated effluent, avoiding the utilization of drinking water in uses where the drinkable standards are not required. The objective of this study was to elaborate a project of a wastewater treatment plant and to evaluate the results obtained on the reutilization of the treated sanitary sewage. The treatment units are: anoxic reactor, oxidation ditch, secondary clarifier, biological filter, re-oxygenation tank, up flow filter, slow filter, UV disinfection and application of chlorine in line. The research was carried out during a period of 9 months (oct/08 to jun/09). The results indicated an average removal up to 94% of total suspended solids, 96,4% of BOD, 97,5% of COD and 99% of color. The analysis of FOG, ammonia nitrogen, volatile organic compounds didn't reach the method limits. The counting for total coliforms reached 17,4 NMP/100mL and 1,54 NMP/100mL fo E.coli after disinfection per UV reactor. The results obtained for turbidity (0,92 NTU) and dissolved oxygen (5,16 mg/L) where similar for the obtained values on the drinkable water that showed turbidity of 0,35 NTU and dissolved oxygen of 5,23 mg/L. The average of the results of color on the water for reuse was 25 UH, and was perceived by the users due to the white toilet basins. The application of chlorine in line on the distribution of the water for reuse was an important factor for color reduction, but the results ranged from 19 to 95% of color removal, indicating the need of better control in this step. At the end of the study it is presented a proposal for a new set of standards for the water reutilization to flush toilet basins / Doutorado / Saneamento e Ambiente / Doutor em Engenharia Civil
2

Leitos cultivados no tratamento de esgoto / Constructed wetlands in the treatment of wastewater

Vargas, Rônega Boa Sorte, 1987- 05 July 2015 (has links)
Orientador: José Teixeira Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-28T08:54:27Z (GMT). No. of bitstreams: 1 Vargas_RonegaBoaSorte_M.pdf: 2884984 bytes, checksum: 6fed8f1b1df702794d2885de0c6af917 (MD5) Previous issue date: 2015 / Resumo: O uso de leitos cultivados (LC) é uma alternativa no tratamento de efluentes, pois atuam na retenção/remoção dos nutrientes e/ou substâncias químicas. Com base nesta abordagem, a presente pesquisa objetivou avaliar o desempenho dos sistemas de leitos cultivados de fluxo subsuperficial no pós-tratamento de efluentes domésticos de Reatores Anaeróbios Compartimentados (RAC). O sistema é composto de três unidades de leitos cultivados: sendo LC1-leito cultivada sem planta, LC2-leito cultivado com Canna×generalis L e LC3-leito cultivado com Eichhornia crassipes. Foram monitorados aspectos meteorológicos (Temperatura e Precipitação), da vegetação (determinação da biomassa verde e seca), quantitativo do afluente/efluente (Vazão, Evapotranspiração e Tempo de Detenção Hidráulica) e qualitativo do afluente/efluente (Temperatura, Oxigênio Dissolvido, Potencial Hidrogeniônico, Demanda Química de Oxigênio, Fósforo Total, Nitrito, Nitrato, Nitrogênio Amoniacal, Nitrogênio Total Kjeldahl, Nitrogênio Total). Analisou-se as três unidades de leitos separadamente e posteriormente comparou-se os resultados obtidos entre eles. Sendo possível observar que o LC3, cultivado com Eleocharis crassipes (Aguapé) foi a unidade de LC com maior destaque das três unidades de leitos cultivados, visto que esse LC foi o mais eficiente para os parâmetros Demanda Química de Oxigênio (DQO), Fósforo Total, Nitrogênio Amoniacal, Nitrogênio Total Kjeldahl (NTK) e Nitrogênio Total (NT). O LC1 (sem planta) foi mais eficiente para os parâmetros Nitrito e Nitrato. Enquanto que o LC2, cultivado com a espécie ornamental Canna×generalis L. (Biri), apesar de ter obtido eficiência satisfatória, não se destacou em relação às demais unidades de LC pesquisadas para nenhum dos parâmetros analisados. Conclui-se que o sistema de leitos cultivados utilizado no pós-tratamento de efluente de Reator Anaeróbio Compartimentado (RAC) mostrou-se, de forma geral, eficiente para retenção/remoção dos parâmetros analisados / Abstract: The use of constructed wetlands (CW) is an alternative treatment of effluents, because they act in the retention/removal of nutrients and/or chemicals. Based on this approach, the present study aimed to evaluate the performance of subsurface flow CW systems in post-treatment of effluent after anaerobic baffled reactor (ABR). The system consists of three units of wetlands: the first one has any plant (LC1), the other were cultivated with ornamental species Canna x generalis L. (LC2), and the third one were cultivated with Eleocharis crassipes (LC3). It were monitored some meteorological aspects (temperature and precipitation), vegetation aspects (green and dried biomass determination), qualitative aspect of affluent/effluent (Flow, Evapotranspiration and Hydraulic Retention Time) and quality of the affluent/effluent (Temperature, Dissolved Oxygen, Hydrogen Potential, Chemical Oxygen Demand, Total Phosphorus, Nitrite, Nitrate, Ammoniacal Nitrogen, Total Kjeldahl Nitrogen, Total Nitrogen). It was analyzed the three units of beds separately then it was made the comparison of these obtained results between them. It¿s possible to see that LC3, the one which were cultivated with Eleocharis crassipes, was the most notably CW unit, because it¿s show the best efficiency for the parameters Biochemical Oxygen Demand (BOD), Total Phosphorus, Conductivity Meters, Total Kjeldahl nitrogen (TKN) and Total Nitrogen (TN). The LC1 (no plant) was more efficient to nitrite and nitrate. At least, LC2, the one cultivated with ornamental species Canna x generalis L. (Biri), despite had received satisfactory efficiency, it did not stand out compared to other LC units surveyed for the parameters analyzed. It follows that the system of wetlands used in the post-treatment of Anaerobic Baffled Reactor (ABR) effluent proved that, in general, can be effective for retention/remotion of analyzed parameters / Mestrado / Agua e Solo / Mestra em Engenharia Agrícola
3

Desinfecção de efluentes sanitarios por cloração visando o uso na agricultura / Chorine desinfection of sanitary effluents aiming agricultural use

Tonon, Daniele 15 March 2007 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T00:15:10Z (GMT). No. of bitstreams: 1 Tonon_Daniele_M.pdf: 3768702 bytes, checksum: 5674b41afca2a80b6486eb02fa20eef2 (MD5) Previous issue date: 2007 / Resumo: A desinfecção de águas residuárias, tanto para atender a padrões de lançamento em corpos receptores quanto para o reúso agrícola, é um processo de tratamento indispensável à proteção da saúde publica. Neste trabalho o hipoclorito de cálcio apresenta-se como desinfetante, pois, uma das grandes vantagens desta técnica é que ela deixa um residual de cloro em contato com os efluentes capaz de eliminar os organismos causadores das principais doenças de veiculação hídrica, o inconveniente desta técnica é a provável formação de subprodutos da desinfecção, os chamados trialometanos. O objetivo geral proposto por este trabalho é a avaliação da desinfecção de efluentes de uma lagoa anaeróbia, situada em Franca, São Paulo e administrada pela Sabesp; e, dos efluentes das valas de filtração construídas com 0,25, 0,50 e 0,75m de camada de areia, as quais foram alimentadas com efluente proveniente de uma fossa filtro e coletada na ETE Icaraí, administrada pela Sanasa, Campinas, São Paulo. Na desinfecção foi utilizado hipoclorito de cálcio promovendo variações dos tempos de contato em 30, 45 e 60 minutos. Dosagens de hipoclorito de cálcio entre 25 e 32 mg L-1 e dosagens 1,6 e 3,25 mg L-1 foram necessárias para adequar os efluentes da lagoa anaeróbia e das valas de filtração, respectivamente, aos padrões estabelecidos pela OMS (1989) para reúso agrícola; e, pela CONAMA 357/05, para padrões de lançamento em corpos receptores de classe 2. Os resultados sobre inativação de protozoários e helmintos foram considerados não satisfatórios para o efluente da lagoa anaeróbia e para as valas de filtração verificou-se que há uma retenção desses microrganismos nas camadas de areia / Abstract: The wastewater disinfection is an indispensable pratice to the protection of public health, it needs to follow the standards estabilished of launching water in the rivers and lakes and for the reuse on agriculture. In this process the hypochlorite of calcium is presented as disinfecting agent, therefore, one of the great advantages of this technique is that it leaves a residual of chlorine in contact with effluents capable to eliminate organisms causing of the main illnesses of hydric propagation, the inconvenience of this technique is the probable by-product formation of the disinfection, called the trihalomethanes. The general objective considered by this work is the evaluation of the disinfection of effluent of an anaerobic pond, situated in Franca, São Paulo and managed by the Sabesp and of the effluent ones of the ditches of filtration of 0,25, 0,50 and 0,75m of effluent sand layer fed with proceeding from one fosse filter and collected in the ETE Icaraí managed for the Sanasa, Campinas, São Paulo, with hypochlorite of calcium varying the times of contact in 30, 45 and 60 minutes. Dosages of hypochlorite of calcium between 25 and 32 mg L-1 and dosages 1,6 and 3,25 mg L-1 had been necessary to adjust the effluent of the anaerobic pond and the ditches of filtration, respectively, to the standards established for the OMS (1989) for agriculture reuse and CONAMA 357/05 for standards of launching in the receptors of class 2. The results on inactivation of protozoa and helminths have been considered not satisfactory for the effluent ones of the anaerobic ponds and for the filtration ditches it was verified that it has a retention of these microorganisms in the sand layers / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
4

Estudo das condiÃÃes laborais em estaÃÃes de tratamento de esgoto / STUDY OF CONDITIONS FOR INDUSTRIAL STATIONS IN TREATMENT OF WASTEWATER

Francisco das Chagas Neto 12 December 2005 (has links)
nÃo hà / A poluiÃÃo dos recursos hÃdricos vem aumentando drasticamente, em todo o mundo. Dentre as soluÃÃes adotadas, tem-se a implantaÃÃo de EstaÃÃes de Tratamento de Esgotos - ETEâs, as quais devem ser estudadas como plantas industriais, que servem à sociedade. As ETEâs, como qualquer indÃstria, sofrem dos problemas de higiene industrial e de seguranÃa do trabalho. Nesta pesquisa estuda-se os riscos laborais, tanto ambientais quanto operacionais, os quais os empregados do setor de saneamento estÃo expostos nas etapas do sistema de tratamento de esgoto possuindo caracterÃsticas de unidades industriais. AtravÃs de pesquisas bibliogrÃficas, questionÃrios e verificaÃÃo das Normas Regulamentadoras â NRâs existentes, complementadas com visitas realizadas a algumas ETEâs da Companhia de Ãgua e Esgoto do Cearà â CAGECE e entrevistas com os empregados das mesmas, foi possÃvel levantar as condiÃÃes de trabalho e tipos de acidentes que ocorrem. Foram verificados os procedimentos e manuais da Ãrea de seguranÃa e higiene no trabalho da mesma, bem como constatado a nÃo existÃncia de uma Norma especÃfica para o setor de saneamento como, tambÃm, uma ClassificaÃÃo Nacional de Atividades EconÃmicas - CNAE que represente diretamente as ETEâs, seus acidentes e empregados. Pode-se verificar que muitos dos que ocorrem atualmente jà tinham sido relatados a dÃcadas atrÃs e que muitos dos manuais e procedimentos devem ser atualizados e ter uma linguagem mais acessÃvel ao trabalhador. Dos questionÃrios aplicados, a totalidade foi respondida. Constatou-se que a divulgaÃÃo dos dados de acidentes, bem como procedimentos de seguranÃa por parte da CAGECE à transparente. Assim, foi possÃvel montar um quadro geral dos acidentes e riscos existentes nas ETEâs. / Water pollution is growing drastically worldwide. Among the solutions adopted is the installation of wastewater treatment plants. They have to be considered industrial units at the service of the community that like any other unit of that type, suffers from problems related to hygiene and labor safety. In this research we studied labor hazards, ambient and operational, to which operators of treatment plants are exposed during the phases of industrial style waste water treatment. Methods applied include literature studies, questionnaires, verification of the existing safety norms, visiting of some treatment units of CAGECE â Companhia de Ãgua e Esgoto do CearÃ, and interviews with workers in order to learn about the working conditions and accidents occurred. The procedures applied and the safety and hygiene manuals were verified. We confirmed the lack of specific norms for the sanitation sector and of the âNational Classification of Economic Activities â CNAEâ that should consider waste water treatment, its workers and accidents they suffer. We found that many of the actual accidents were reported already decades ago; but manuals and procedures remained unchanged exhibiting, in addition, a language inaccessible for the workers. From the questionnaires, fully returned by the workers, we learned that the divulgement by CAGECE of safety procedures and accidents is transparent. This allowed a complete insight into accidents and risks occurring in waste water treatment plants.

Page generated in 0.2762 seconds