Cultura dos tecidos profundos na artroplastia total primária do quadril: valor prognóstico para infecção periprotética / Multiple deep tissue cultures in primary total hip arthroplasty: prognostic value for periprosthetic infectionFerro, Fernando Portilho 27 March 2019 (has links)
INTRODUÇÃO: A artroplastia total do quadril é um dos procedimentos mais frequentes na ortopedia. O risco de infecção varia de 1 a 5%, e acarreta grande impacto negativo na qualidade de vida do paciente, além de envolver custos expressivos. O diagnóstico e tratamento precoce da infecção permite um tratamento mais rápido e efetivo, o que pode melhorar o resultado clínico final. Sabe-se que germes patogênicos podem contaminar o campo cirúrgico durante a cirurgia, apesar de rigorosa técnica asséptica, mas existe debate na literatura sobre a existência de benefício em identificar tais germes já na artroplastia primária em pacientes não infectados. Embora a coleta de múltiplas amostras para cultura seja prática bem estabelecida em procedimentos de revisão, permanece controversa a coleta de culturas em artroplastias primárias. Diversas bactérias podem contaminar o campo operatório durante a cirurgia, mas somente seriam capazes de causar infecção aquelas que contaminarem os planos anatômicos mais profundos. O objetivo deste estudo foi investigar se há valor prognóstico na realização de cultura de amostras profundas de tecido ósseo e de partes moles durante a realização da artroplastia total primária do quadril, buscando correlação entre a positividade das culturas e de infecção periprotética subsequente. MÉTODOS: Estudo retrospectivo, utilizando informações obtidas do prontuário médico e do sistema informatizado de consulta de exames laboratoriais. Foram colhidas amostras profundas (osso femoral, acetabular e cápsula) de 426 casos consecutivos de artroplastia total primária eletiva do quadril. Os pacientes foram seguidos por no mínimo três anos e foram identificados os pacientes que evoluíram com infecção. O perfil microbiológico das culturas nas cirurgias primárias foi comparado com aquele dos pacientes infectados. Adicionalmente, os prontuários foram revisados para a identificação de fatores de risco associados a maior risco de infecção periprotética. RESULTADOS: 54 cirurgias (12,6%) apresentaram culturas positivas. 16 casos (3,8%) evoluíram com infecção, dos quais cinco haviam apresentado cultura positiva na cirurgia primária. Os germes isolados nos pacientes infectados não coincidiram com os identificados na cirurgia índice. A taxa de infecção foi de 9,3% nos pacientes com cultura positiva e 3% naqueles com cultura negativa (p < 0,05), com um \"odds ratio\" de 3,34 (IC95% 1,09-10,24). Pacientes submetidos a alguma cirurgia prévia no quadril apresentaram taxa de infecção de 8,5%, sendo que tal percentual foi de 2,9% nos pacientes sem cirurgia prévia (p < 0,05). O único fator de risco associado a uma maior positividade de culturas foi o tabagismo (10,5% vs 23,6%, p < 0,05). CONCLUSÃO: Dentre os pacientes submetidos à artroplastia total primária do quadril, aqueles com cultura positiva apresentaram maior risco de desenvolvimento de infecção periprotética (IPP). Pacientes submetidos a algum procedimento cirúrgico prévio no mesmo quadril apresentaram maior risco de IPP / INTRODUCTION: The total hip arthroplasty is one of the most frequent procedures in orthopedics. The risk of infection usually varies from 1% to 5% and has a great negative impact on patients\' quality of life, while also involving significant costs. The diagnosis and early treatment of infection allows a faster and more effective treatment, which can improve the final clinical result. It is known that pathogenic germs can contaminate the surgical theater, despite strict aseptic technique, but there is debate in the literature regarding the benefit of identifying such germs during the primary arthroplasty in non-infected patients. Although the obtainment of multiple samples for culture is a well-established practice in revision procedures, the obtainment of cultures in primary arthroplasties remains controversial. Several bacteria can contaminate the operative field during surgery, but only those that contaminate the deeper anatomical layers should be capable of causing infection. The aim of this study was to investigate if there is prognostic value in the culture of deep samples of bone and soft tissues during primary total hip arthroplasty, seeking a correlation between the positivity of the cultures and subsequent periprosthetic infection. METHODS: This was a retrospective study, using information obtained from medical records and a computerized system for consultation of laboratory tests. Deep samples (femoral bone, acetabular bone and capsule) were collected from 426 consecutive cases of elective primary total hip arthroplasty. Patients were followed up for at least three years and patients who had developed infection were identified. The microbiological profile of cultures in the primary surgeries was compared to that of the infected patients. In addition, the medical records were reviewed for the identification of risk factors associated with a higher risk of periprosthetic infection. RESULTS: 54 surgeries (12.6%) presented positive cultures. 16 cases (3.8%) developed infection, of which five had presented a positive culture in the primary surgery. Isolated germs in infected patients did not coincide with those identified in the index surgery. The infection rate was 9.3% in patients with positive culture and 3% in those with negative culture (p < 0.05), with an odds ratio of 3.34 (95% CI 1.09-10.24). Patients who had a previous hip surgery had an infection rate of 8.5%, and this percentage was 2.9% in patients with no previous surgery (p < 0.05). The only risk factor associated with a higher risk of culture positivity was smoking (10.5% vs. 23.6%, p < 0.05). CONCLUSION: Among patients undergoing primary total hip arthroplasty, those with a positive culture had a higher risk of developing periprosthetic infection (PPI). Patients who had undergone previous surgical procedures in the same hip also presented a higher risk of PPI
|
2 |
Avaliação da eficácia da esterização de furadeiras elétricas domésticas utilizadas em cirurgias ortopédicas / Evaluation of the efficacy of the sterilization of ordinary electric drills for orthopedic surgeriesGoveia, Vania Regina 20 December 2007 (has links)
Estima-se que há mais de 50 anos, as furadeiras elétricas (FE) têm sido empregadas em cirurgias ortopédicas nos hospitais brasileiros para a perfuração óssea. Trata-se de equipamento elétrico, termossensível, não indicado para uso cirúrgico, não avaliado anteriormente quanto à eficácia da esterilização, suspeitando-se de risco potencial para infecções do sítio cirúrgico ou relacionadas a próteses ortopédicas. Os objetivos desse estudo foram: avaliar a carga microbiana de FE do uso cirúrgico e avaliar a eficácia da esterilização por óxido de etileno (ETO) de FE novas intencionalmente contaminadas. Trata-se de pesquisa experimental, laboratorial, randomizada e aplicada desenvolvida no laboratório de pesquisas experimentais da Escola de Enfermagem da Universidade de São Paulo. O trabalho foi realizado em duas fases. As condições assépticas foram rigorosamente seguidas para o controle das variáveis. Quinze FE analisadas na fase I, tiveram distribuição aleatória e cega, capturadas em um centro cirúrgico de um hospital escola. Foram cultivados: o ar gerado pelo motor e alíquotas de 10 µL do lavado das superfícies interna e externa das FE. Ainda nessa fase foi realizado um controle positivo onde uma FE foi contaminada com Serratia marcescens e um teste do método de filtração por membrana de porosidade de 0,45 µm com uma FE limpa, onde as membranas que filtraram diferentes quantidades do lavado foram cultivadas. Na fase II foram analisadas 22 FE e três perfuradores de osso (PO). Dezesseis FE constituíram o grupo experimental (GE), seis o controle positivo (GCP) e três PO constituíram o controle negativo (GCN). Todos os equipamentos previamente limpos e esterilizados foram submetidos à contaminação com esporos de Bacillus atrophaeus. As FE do GCP foram analisadas após a exposição ao contaminante, furadeiras do GE e perfuradores do GCN foram submetidos à limpeza e esterilização por ETO antes de serem analisados. Foram cultivados: ar gerado pelo motor e membrana filtrante após a filtração do lavado das superfícies interna e externa dos equipamentos. Foram realizadas coloração e microscopia: Gram para culturas positivas; Wirtz-Conklin para culturas positivas com bacilos Gram positivos. Os resultados mostraram que a carga microbiana de FE do uso cirúrgico é baixa e foi detectada em duas ocasiões no cultivo do ar, 1 ufc/FE e em uma ocasião no cultivo de alíquotas do lavado, 9 ufc/FE. O controle positivo realizado com Serratia marcescens comprovou a sensibilidade do método para amostras contendo alta concentração de contaminantes. O método filtração por membrana mostrou-se sensível para detectar baixa contaminação das FE, sendo o eleito para o teste de esterilidade. Os controles positivos apresentaram crescimento do microrganismo contaminante, comprovando a aderência ao material. Os controles negativos não apresentaram crescimento. Das 16 FE do GE, duas apresentaram crescimento sendo cada uma delas de 1ufc do contaminante inicial respectivamente no cultivo do ar e no cultivo da membrana. Foi comprovada a eficiência de 99,99999881% do processo de esterilização por ETO, com a probabilidade de sobrevivência de 1,19 x 10-8. Nas condições do desenvolvimento do experimento, a eficácia da esterilização das FE por ETO foi comprovada / Electric drills have been used to perform orthopedic surgeries in Brazilian hospitals for almost more than 50 years. This electric equipment is heat-sensitive and it is not appropriate to use in surgical procedures. Until now the efficacy of sterilization of this item had been not evaluated as a potential risk for the occurrence of surgical site infection or infection related to orthopedic prosthesis. The objectives of this study were to evaluate the bioburden of the used electric drills and to evaluate the sterility of the new electric drills contaminated artificially. It is an experimental and randomized study performed in the research laboratory of the Nursing School of the São Paulo University. The study was performed in two phases following rigorous aseptic techniques to control the variables. In the first phase fifteen electric drills were taken in the operating room of the university hospital and included in the study using aleatory and blind methods. Cultures were performed from the air produced by the drill engine and the aliquots of 10µL of the rinsed water from the internal and external surface of the electric drill. One electric drill was included as a positive control and was contaminated with Serratia marcescens. A membrane filter with porous of 0,45 µm were cultured after had been exposed to the rinsed water from the internal and external surface of the clean electric drill. In the second phase were analyzed twenty two electric drills and three orthopedic drilling machines. Sixteen electric drills were included in the experimental group, six were the positive control group and three orthopedic drilling machines in the negative control group. All the equipments previously cleaned and sterilized were submitted to the contamination with Bacillus atrophaeus. The electric drills included in the positive control group were analyzed after exposed to the contaminant and the electric drills of the experimental group and orthopedic drills included in the negative control group were submitted to clean and ethylene oxide sterilization before to start the analysis. The air produced by the drill engine and the membrane filter after exposed to the rinsed water of the internal and external surface of the electric drill were cultured. It was performed Gram microscopy and Wirtz-Conklin to Gram positive bacilli. The results showed low bioburden in the electric drills in two episodes. So, 1 cfu/electric drill was found in one episode of the air culture and 9 cfu/electric drill in one episode of culture of the aliquot. The positive control with Serratia marcescens demonstrated the sensibility of the method in samples with high concentration of contaminants. The method of membrane filtration showed sensible to detect low bioburden of the electric drills. So it is elected for the sterility test. The positive controls showed the growth of the contaminant microrganism demonstrating the adherence to the material surface. The negative controls did not show growth. Two of the sixteen electric drills included in the experimental group showed each one growth of 1cfu of the initial contaminant of the air and the membrane cultures respectively. So the efficiency of the sterilization process was 99,99999881% and the probability of find survivor was 1,19 x 10-8. In these conditions the study demonstrates that the efficacy of the ethylene oxide sterilization was proved
|
3 |
Avaliação da eficácia da esterização de furadeiras elétricas domésticas utilizadas em cirurgias ortopédicas / Evaluation of the efficacy of the sterilization of ordinary electric drills for orthopedic surgeriesVania Regina Goveia 20 December 2007 (has links)
Estima-se que há mais de 50 anos, as furadeiras elétricas (FE) têm sido empregadas em cirurgias ortopédicas nos hospitais brasileiros para a perfuração óssea. Trata-se de equipamento elétrico, termossensível, não indicado para uso cirúrgico, não avaliado anteriormente quanto à eficácia da esterilização, suspeitando-se de risco potencial para infecções do sítio cirúrgico ou relacionadas a próteses ortopédicas. Os objetivos desse estudo foram: avaliar a carga microbiana de FE do uso cirúrgico e avaliar a eficácia da esterilização por óxido de etileno (ETO) de FE novas intencionalmente contaminadas. Trata-se de pesquisa experimental, laboratorial, randomizada e aplicada desenvolvida no laboratório de pesquisas experimentais da Escola de Enfermagem da Universidade de São Paulo. O trabalho foi realizado em duas fases. As condições assépticas foram rigorosamente seguidas para o controle das variáveis. Quinze FE analisadas na fase I, tiveram distribuição aleatória e cega, capturadas em um centro cirúrgico de um hospital escola. Foram cultivados: o ar gerado pelo motor e alíquotas de 10 µL do lavado das superfícies interna e externa das FE. Ainda nessa fase foi realizado um controle positivo onde uma FE foi contaminada com Serratia marcescens e um teste do método de filtração por membrana de porosidade de 0,45 µm com uma FE limpa, onde as membranas que filtraram diferentes quantidades do lavado foram cultivadas. Na fase II foram analisadas 22 FE e três perfuradores de osso (PO). Dezesseis FE constituíram o grupo experimental (GE), seis o controle positivo (GCP) e três PO constituíram o controle negativo (GCN). Todos os equipamentos previamente limpos e esterilizados foram submetidos à contaminação com esporos de Bacillus atrophaeus. As FE do GCP foram analisadas após a exposição ao contaminante, furadeiras do GE e perfuradores do GCN foram submetidos à limpeza e esterilização por ETO antes de serem analisados. Foram cultivados: ar gerado pelo motor e membrana filtrante após a filtração do lavado das superfícies interna e externa dos equipamentos. Foram realizadas coloração e microscopia: Gram para culturas positivas; Wirtz-Conklin para culturas positivas com bacilos Gram positivos. Os resultados mostraram que a carga microbiana de FE do uso cirúrgico é baixa e foi detectada em duas ocasiões no cultivo do ar, 1 ufc/FE e em uma ocasião no cultivo de alíquotas do lavado, 9 ufc/FE. O controle positivo realizado com Serratia marcescens comprovou a sensibilidade do método para amostras contendo alta concentração de contaminantes. O método filtração por membrana mostrou-se sensível para detectar baixa contaminação das FE, sendo o eleito para o teste de esterilidade. Os controles positivos apresentaram crescimento do microrganismo contaminante, comprovando a aderência ao material. Os controles negativos não apresentaram crescimento. Das 16 FE do GE, duas apresentaram crescimento sendo cada uma delas de 1ufc do contaminante inicial respectivamente no cultivo do ar e no cultivo da membrana. Foi comprovada a eficiência de 99,99999881% do processo de esterilização por ETO, com a probabilidade de sobrevivência de 1,19 x 10-8. Nas condições do desenvolvimento do experimento, a eficácia da esterilização das FE por ETO foi comprovada / Electric drills have been used to perform orthopedic surgeries in Brazilian hospitals for almost more than 50 years. This electric equipment is heat-sensitive and it is not appropriate to use in surgical procedures. Until now the efficacy of sterilization of this item had been not evaluated as a potential risk for the occurrence of surgical site infection or infection related to orthopedic prosthesis. The objectives of this study were to evaluate the bioburden of the used electric drills and to evaluate the sterility of the new electric drills contaminated artificially. It is an experimental and randomized study performed in the research laboratory of the Nursing School of the São Paulo University. The study was performed in two phases following rigorous aseptic techniques to control the variables. In the first phase fifteen electric drills were taken in the operating room of the university hospital and included in the study using aleatory and blind methods. Cultures were performed from the air produced by the drill engine and the aliquots of 10µL of the rinsed water from the internal and external surface of the electric drill. One electric drill was included as a positive control and was contaminated with Serratia marcescens. A membrane filter with porous of 0,45 µm were cultured after had been exposed to the rinsed water from the internal and external surface of the clean electric drill. In the second phase were analyzed twenty two electric drills and three orthopedic drilling machines. Sixteen electric drills were included in the experimental group, six were the positive control group and three orthopedic drilling machines in the negative control group. All the equipments previously cleaned and sterilized were submitted to the contamination with Bacillus atrophaeus. The electric drills included in the positive control group were analyzed after exposed to the contaminant and the electric drills of the experimental group and orthopedic drills included in the negative control group were submitted to clean and ethylene oxide sterilization before to start the analysis. The air produced by the drill engine and the membrane filter after exposed to the rinsed water of the internal and external surface of the electric drill were cultured. It was performed Gram microscopy and Wirtz-Conklin to Gram positive bacilli. The results showed low bioburden in the electric drills in two episodes. So, 1 cfu/electric drill was found in one episode of the air culture and 9 cfu/electric drill in one episode of culture of the aliquot. The positive control with Serratia marcescens demonstrated the sensibility of the method in samples with high concentration of contaminants. The method of membrane filtration showed sensible to detect low bioburden of the electric drills. So it is elected for the sterility test. The positive controls showed the growth of the contaminant microrganism demonstrating the adherence to the material surface. The negative controls did not show growth. Two of the sixteen electric drills included in the experimental group showed each one growth of 1cfu of the initial contaminant of the air and the membrane cultures respectively. So the efficiency of the sterilization process was 99,99999881% and the probability of find survivor was 1,19 x 10-8. In these conditions the study demonstrates that the efficacy of the ethylene oxide sterilization was proved
|
4 |
"Estudo comparativo do tratamento das artroplastias infectadas do quadril sem e com o uso do espaçador de cimento com antibiótico" / Prospective study of the treatment of chronically infected hip replacements with and without the use of an antibiotic-loaded acrylic cement spacerCabrita, Henrique Antonio Berwanger de Amorim 12 April 2004 (has links)
Em um estudo prospectivo sobre o tratamento das artroplastias de quadril infectadas, com perdas ósseas e fístulas ativas, 25 pacientes foram tratados em dois tempos e 36 pacientes foram tratados em dois tempos com espaçador de cimento impregnado com vancomicina. O acompanhamento médio foi de dois anos e onze meses. A taxa de recidiva infecciosa foi de 29,2% nos tratados em dois tempos e de 8,8% nos tratados com espaçador. O Escore de Harris para Quadril médio passou de 19,3 para 69,0 pontos nos casos tratados em dois tempos e de 19,7 para 72,2 pontos nos pacientes tratados com espaçador. Ao final do estudo, 86,1% dos tratados com espaçador e em 33,3% dos tratados em dois tempos tinham próteses em bom funcionamento e sem infecção. O espaçador de cimento com antibiótico é o tratamento de escolha nas próteses infectadas de quadril / We report a prospective study of 61 patients with chronically deep infected hip replacements with actively discharging sinuses, treated with a two-stage revision protocol, with and without a cement spacer impregnated with vancomycin. The average follow-up was two years and eleven months. Twenty-five patients were treated without a spacer and seven had recurrence of infection. Thirty-three patients were treated with a spacer and three had recurrence of infection. The average Harris Hip score increased from 19,3 to 69,0 on the non-spacer patients and from 19,7 to 75,2 on the spacer group. At the end of the study, the success rate was 86,1% for the spacer group and 33,3% for the non-spacer group. The use of the spacer increased the results of the two-stage chronic infected hip replacements
|
5 |
"Estudo comparativo do tratamento das artroplastias infectadas do quadril sem e com o uso do espaçador de cimento com antibiótico" / Prospective study of the treatment of chronically infected hip replacements with and without the use of an antibiotic-loaded acrylic cement spacerHenrique Antonio Berwanger de Amorim Cabrita 12 April 2004 (has links)
Em um estudo prospectivo sobre o tratamento das artroplastias de quadril infectadas, com perdas ósseas e fístulas ativas, 25 pacientes foram tratados em dois tempos e 36 pacientes foram tratados em dois tempos com espaçador de cimento impregnado com vancomicina. O acompanhamento médio foi de dois anos e onze meses. A taxa de recidiva infecciosa foi de 29,2% nos tratados em dois tempos e de 8,8% nos tratados com espaçador. O Escore de Harris para Quadril médio passou de 19,3 para 69,0 pontos nos casos tratados em dois tempos e de 19,7 para 72,2 pontos nos pacientes tratados com espaçador. Ao final do estudo, 86,1% dos tratados com espaçador e em 33,3% dos tratados em dois tempos tinham próteses em bom funcionamento e sem infecção. O espaçador de cimento com antibiótico é o tratamento de escolha nas próteses infectadas de quadril / We report a prospective study of 61 patients with chronically deep infected hip replacements with actively discharging sinuses, treated with a two-stage revision protocol, with and without a cement spacer impregnated with vancomycin. The average follow-up was two years and eleven months. Twenty-five patients were treated without a spacer and seven had recurrence of infection. Thirty-three patients were treated with a spacer and three had recurrence of infection. The average Harris Hip score increased from 19,3 to 69,0 on the non-spacer patients and from 19,7 to 75,2 on the spacer group. At the end of the study, the success rate was 86,1% for the spacer group and 33,3% for the non-spacer group. The use of the spacer increased the results of the two-stage chronic infected hip replacements
|