• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • Tagged with
  • 41
  • 41
  • 27
  • 26
  • 12
  • 9
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Enxertos ósseos liofilizados e impactados humano e bovino em revisão de artroplastia total de quadril

Galia, Carlos Roberto January 2004 (has links)
O presente estudo é uma coorte não concorrente em 63 pacientes (66 quadris) submetidos à revisão de artroplastia total de quadril (RATQ), com enxerto ósseo liofilizado moído e impactado. Foi realizado no Serviço de Ortopedia e Traumatologia do Hospital de Clínicas de Porto Alegre (HCPA), no período de maio de 1997 a setembro de 2003. O objetivo do estudo foi comparar clínica, radiográfica e cintilograficamente a capacidade de osteointegração dos enxertos ósseos liofilizados humano e bovino impactados em RATQs cimentadas e não-cimentadas. Os pacientes foram divididos em dois grupos: o Grupo 1 (n=35) foi composto pelos que receberam enxerto ósseo liofilizado de origem humana e o Grupo 2 (n=31) por aqueles que receberam enxerto de origem bovina. O tempo médio de seguimento foi de 33 meses. Os enxertos ósseos purificados e liofilizados foram produzidos pelo Banco de Tecidos do HCPA. A análise clínica baseou-se no escore de Merle, d’Aubigné e Postel; a radiográfica, nos critérios de radioluscência, densidade, formação de trabeculado ósseo, migração dos componentes e floculação, formulando-se um escore radiográfico de osteointegração (EROI). Foram escolhidos, aleatoriamente, como forma complementar de análise por imagem, 35 (53%) pacientes assintomáticos para realizarem cintilografia óssea com Tecnécio, sendo 17 (48,5%) do Grupo 1 e 18 (51,5%) do Grupo 2. Não foram encontradas diferenças clínicas, radiográficas ou cintilográficas relevantes entre os grupos, obtendo-se em torno de 85% de integração do enxerto, tanto no componente acetabular quanto femoral. Estes resultados são comparáveis aos relatados na literatura com o uso de enxerto alogênico congelado e confirmam a adequacidade do uso de enxertos liofilizados de origem bovina e humana em RATQ. / This is a non-concurrent cohort trial of 63 patients (66 hips) submitted to revision total hip arthroplasty (RTHA) using impacted freeze-dried cancellous bone grafts. The study was carried out in the Orthopedics and Traumatology Unit of Hospital de Clinicas de Porto Alegre (HCPA) from May 1997 to September 2003. The main purpose of the study was to compare clinical, radiographic and scintigraphic graft incorporation capability between human and bovine freeze-dried bone grafts. Patients were divided into two groups: Group 1 (n=35) was composed of those receiving human grafts and Group 2 (n=31) of those receiving grafts of bovine source. The median follow-up was 33 months and no death or major complications occurred in this series. The grafts were purified and freeze-dried at the Tissue Bank of the HCPA. The clinical analysis was based on the score of Merle, d’Aubigné and Postel; and the radiographic analysis on the criteria of radiolucency, density, trabecula formation, migration and “cotton flock” appearance by using these parameters, isolated or combined in an established score for radiographic bone incorporation (SCORBI). Thirty-five (53%) asymptomatic patients, 18 (51%) and 17 (49%) from Groups 1 and 2 respectively, were randomly selected to be assessed by 99mTc scintigraphy, as a complementary form of image analysis. No clinical, radiographic or scintigraphic differences were observed between the groups and both groups showed around 85% of graft integration both in the acetabular and in the femoral component. These results are comparable to those reported in the literature with the use of deep-frozen grafts. Therefore, bovine and human freeze-dried grafts can be safely and adequately used in RTHA.
2

Reabilitação após artroplastia total do quadril : um ensaio clínico randomizado

Umpierres, Carolina Sant'Anna January 2012 (has links)
Resumo não disponível
3

Enxertos ósseos liofilizados e impactados humano e bovino em revisão de artroplastia total de quadril

Galia, Carlos Roberto January 2004 (has links)
O presente estudo é uma coorte não concorrente em 63 pacientes (66 quadris) submetidos à revisão de artroplastia total de quadril (RATQ), com enxerto ósseo liofilizado moído e impactado. Foi realizado no Serviço de Ortopedia e Traumatologia do Hospital de Clínicas de Porto Alegre (HCPA), no período de maio de 1997 a setembro de 2003. O objetivo do estudo foi comparar clínica, radiográfica e cintilograficamente a capacidade de osteointegração dos enxertos ósseos liofilizados humano e bovino impactados em RATQs cimentadas e não-cimentadas. Os pacientes foram divididos em dois grupos: o Grupo 1 (n=35) foi composto pelos que receberam enxerto ósseo liofilizado de origem humana e o Grupo 2 (n=31) por aqueles que receberam enxerto de origem bovina. O tempo médio de seguimento foi de 33 meses. Os enxertos ósseos purificados e liofilizados foram produzidos pelo Banco de Tecidos do HCPA. A análise clínica baseou-se no escore de Merle, d’Aubigné e Postel; a radiográfica, nos critérios de radioluscência, densidade, formação de trabeculado ósseo, migração dos componentes e floculação, formulando-se um escore radiográfico de osteointegração (EROI). Foram escolhidos, aleatoriamente, como forma complementar de análise por imagem, 35 (53%) pacientes assintomáticos para realizarem cintilografia óssea com Tecnécio, sendo 17 (48,5%) do Grupo 1 e 18 (51,5%) do Grupo 2. Não foram encontradas diferenças clínicas, radiográficas ou cintilográficas relevantes entre os grupos, obtendo-se em torno de 85% de integração do enxerto, tanto no componente acetabular quanto femoral. Estes resultados são comparáveis aos relatados na literatura com o uso de enxerto alogênico congelado e confirmam a adequacidade do uso de enxertos liofilizados de origem bovina e humana em RATQ. / This is a non-concurrent cohort trial of 63 patients (66 hips) submitted to revision total hip arthroplasty (RTHA) using impacted freeze-dried cancellous bone grafts. The study was carried out in the Orthopedics and Traumatology Unit of Hospital de Clinicas de Porto Alegre (HCPA) from May 1997 to September 2003. The main purpose of the study was to compare clinical, radiographic and scintigraphic graft incorporation capability between human and bovine freeze-dried bone grafts. Patients were divided into two groups: Group 1 (n=35) was composed of those receiving human grafts and Group 2 (n=31) of those receiving grafts of bovine source. The median follow-up was 33 months and no death or major complications occurred in this series. The grafts were purified and freeze-dried at the Tissue Bank of the HCPA. The clinical analysis was based on the score of Merle, d’Aubigné and Postel; and the radiographic analysis on the criteria of radiolucency, density, trabecula formation, migration and “cotton flock” appearance by using these parameters, isolated or combined in an established score for radiographic bone incorporation (SCORBI). Thirty-five (53%) asymptomatic patients, 18 (51%) and 17 (49%) from Groups 1 and 2 respectively, were randomly selected to be assessed by 99mTc scintigraphy, as a complementary form of image analysis. No clinical, radiographic or scintigraphic differences were observed between the groups and both groups showed around 85% of graft integration both in the acetabular and in the femoral component. These results are comparable to those reported in the literature with the use of deep-frozen grafts. Therefore, bovine and human freeze-dried grafts can be safely and adequately used in RTHA.
4

Reabilitação após artroplastia total do quadril : um ensaio clínico randomizado

Umpierres, Carolina Sant'Anna January 2012 (has links)
Resumo não disponível
5

Reabilitação após artroplastia total do quadril : um ensaio clínico randomizado

Umpierres, Carolina Sant'Anna January 2012 (has links)
Resumo não disponível
6

Enxertos ósseos liofilizados e impactados humano e bovino em revisão de artroplastia total de quadril

Galia, Carlos Roberto January 2004 (has links)
O presente estudo é uma coorte não concorrente em 63 pacientes (66 quadris) submetidos à revisão de artroplastia total de quadril (RATQ), com enxerto ósseo liofilizado moído e impactado. Foi realizado no Serviço de Ortopedia e Traumatologia do Hospital de Clínicas de Porto Alegre (HCPA), no período de maio de 1997 a setembro de 2003. O objetivo do estudo foi comparar clínica, radiográfica e cintilograficamente a capacidade de osteointegração dos enxertos ósseos liofilizados humano e bovino impactados em RATQs cimentadas e não-cimentadas. Os pacientes foram divididos em dois grupos: o Grupo 1 (n=35) foi composto pelos que receberam enxerto ósseo liofilizado de origem humana e o Grupo 2 (n=31) por aqueles que receberam enxerto de origem bovina. O tempo médio de seguimento foi de 33 meses. Os enxertos ósseos purificados e liofilizados foram produzidos pelo Banco de Tecidos do HCPA. A análise clínica baseou-se no escore de Merle, d’Aubigné e Postel; a radiográfica, nos critérios de radioluscência, densidade, formação de trabeculado ósseo, migração dos componentes e floculação, formulando-se um escore radiográfico de osteointegração (EROI). Foram escolhidos, aleatoriamente, como forma complementar de análise por imagem, 35 (53%) pacientes assintomáticos para realizarem cintilografia óssea com Tecnécio, sendo 17 (48,5%) do Grupo 1 e 18 (51,5%) do Grupo 2. Não foram encontradas diferenças clínicas, radiográficas ou cintilográficas relevantes entre os grupos, obtendo-se em torno de 85% de integração do enxerto, tanto no componente acetabular quanto femoral. Estes resultados são comparáveis aos relatados na literatura com o uso de enxerto alogênico congelado e confirmam a adequacidade do uso de enxertos liofilizados de origem bovina e humana em RATQ. / This is a non-concurrent cohort trial of 63 patients (66 hips) submitted to revision total hip arthroplasty (RTHA) using impacted freeze-dried cancellous bone grafts. The study was carried out in the Orthopedics and Traumatology Unit of Hospital de Clinicas de Porto Alegre (HCPA) from May 1997 to September 2003. The main purpose of the study was to compare clinical, radiographic and scintigraphic graft incorporation capability between human and bovine freeze-dried bone grafts. Patients were divided into two groups: Group 1 (n=35) was composed of those receiving human grafts and Group 2 (n=31) of those receiving grafts of bovine source. The median follow-up was 33 months and no death or major complications occurred in this series. The grafts were purified and freeze-dried at the Tissue Bank of the HCPA. The clinical analysis was based on the score of Merle, d’Aubigné and Postel; and the radiographic analysis on the criteria of radiolucency, density, trabecula formation, migration and “cotton flock” appearance by using these parameters, isolated or combined in an established score for radiographic bone incorporation (SCORBI). Thirty-five (53%) asymptomatic patients, 18 (51%) and 17 (49%) from Groups 1 and 2 respectively, were randomly selected to be assessed by 99mTc scintigraphy, as a complementary form of image analysis. No clinical, radiographic or scintigraphic differences were observed between the groups and both groups showed around 85% of graft integration both in the acetabular and in the femoral component. These results are comparable to those reported in the literature with the use of deep-frozen grafts. Therefore, bovine and human freeze-dried grafts can be safely and adequately used in RTHA.
7

Comparação clínica, laboratorial e densitométrica de pacientes com coxartrose e fraturas do colo femoral

Spinelli, Leandro de Freitas January 2016 (has links)
Resumo não disponível.
8

Estudo da osteonecrose no processo de usinagem da cabeça do fêmur utilizando um dispositivo mecânico de furação / Study of the osteonecrosis in the process of femur head machining by a mechanical drilling device

Higashi, Rosemeire Rosa 12 September 2014 (has links)
A utilização de implantes cirúrgicos para artroplastia de quadril com prótese de recapeamento da cabeça femoral como substituto ósseo é um procedimento que tem sido realizado em 35% dos casos de Osteoartrose nos EUA. Entretanto, o atrito da broca e o aumento da temperatura durante a usinagem da cabeça femoral são responsáveis pelo possível aquecimento do tecido ósseo, podendo provocar a necrose óssea térmica. Neste sentido, o desenvolvimento de novos ferramentais e metodologias para minimizar os danos térmicos do atrito torna-se importante. Diante disso, o presente estudo teve como objetivo verificar se há a ocorrência de necrose óssea em um procedimento de furação óssea utilizando o dispositivo EQUITRON; Mod.ES 2200, desenvolvido no LTC-EESC-USP. Para tal, utilizamos 4 amostras de costela bovina removidas após a morte do animal, que foram furadas com broca de aço inoxidável (HSS-SKF), de 8 milímetros, sem irrigação externa. As amostras foram furadas com rotações de 100, 1000, 1200 e 2500 RPM, aferidas por tacômetro foto/contato digital da marca MINIPA, MDT-2238, e com avanço controlado de 80 mm/min (dispositivo da marca-EQUITRON; MOD.ES 2200; RPM 2800; Potência 0,30; Torque 1,6 Nm). Foram mensuradas as temperaturas iniciais da broca e da amostra e a final da amostra com termômetro digital, marca-MEDISANA®. Após a furação foram confeccionadas lâminas histológicas (HE) do tecido ósseo, preparadas de acordo com a metodologia apropriada, para posterior qualificação e quantificação da ocorrência de necrose óssea térmica através de imagens captadas por microscopia óptica (Olympus BX 41TF - Made Japan) utilizando-se o programa Motic Images Plus 2.0 para a captura das imagens. Os valores de temperaturas aferidos na amostra após a furação apresentaram relação positiva com a RPM utilizada, isto é, quanto maior a rotação, maior foi a temperatura observada. Apenas a amostra furada a 2500 RPM ultrapassou a temperatura de referencia para a gênese da osteonecrose térmica, que é de 47ºC. As análises histológicas apresentaram uma baixa predominância de células picnóticas e lacunas, sugerindo menor dano tecidual. Os resultados obtidos no presente estudo sugerem que o dispositivo (furadeira) desenvolvido no LTC-EESC-USP para a realização das furações nas amostras ósseas em testes de bancada foi eficiente em minimizar a ocorrência de necrose óssea térmica, até mesmo em condições de temperatura acima do limite fisiológico aceitável. / The utilization of surgical implants for hip arthroplasty with a resurfacing prosthesis of the femoral head as a bone substitute have been conducted in 35% of osteoarthrosis cases in the USA. However, the friction of the drill and the increase in the temperature during the machining of the femoral head can possibly heat the bony tissue and provoke a thermal bone necrosis. The development of new tools and methodologies for minimizing the thermal damage of the friction has become fundamental. The present study analyzes the occurrence of bone necrosis in a procedure of bone drilling that uses an EQUITRON device, Mod. ES 2200, developed at the LTC-EESC-USP. Four samples of bovine ribs removed after the death of the animal were used for the tests. They were drilled by an 8mm stainless-steel drill (HSS-SKF) with no external irrigation, at 100, 1000, 1200 and 2500 RPM calibrated by a MINIPA, MDT-2238 digital photo/contact tachometer and whose 80mm/min. advance (EQUITORN device; MOD.ES 2200; RPM 2800; 0.30 Potency and 1,6Nm torque) was controlled. The initial temperatures of the drill and the sample and the final temperature of the sample were measured by a MEDISANA digital thermometer. After drilling, histological blades (HE) were produced from the bony tissue and prepared according to the adequate methodology for further qualification and quantification of the occurrence of thermal bone necrosis through images captured by optical microscopy (Olympus BX 41TF - made in Japan) and Motic Images Plus 2.0 program. The values of the temperatures measured in the sample after drilling showed a positive relation with the RPM utilized, i.e., the faster the rotation, the higher the temperature. Only the sample drilled at 2500RPM exceeded the reference temperature (47ºC) for the genesis of the thermal osteonecrosis. The histological analyses revealed a low predominance of picnotic cells and gaps, which suggest minor tissue damage. The results show the device (drilling machine) developed at the LTC-EESC-USP for the drilling in the bone samples in workbench tests is efficient to minimize the occurrence of thermal bone necrosis, even at temperatures above the physiological acceptable limit.
9

Avaliação preliminar de um protocolo assistencial de artroplastia total do quadril

Galia, Carlos Roberto January 1999 (has links)
A artrose do quadril é uma doença articular degenerativa que atinge principalmente idosos, faixa etária que vem gradativamente aumentando nos últimos tempos. Assim, medidas de racionalização do uso de leitos e recursos hospitalares são necessárias para melhor viabilizar os procedimentos cirúrgicos e reduzir gastos para o sistema de saúde, uma vez que quase dois terços destes gastos decorrem do período de internação. Com esse objetivo, foi desenvolvido um protocolo assistencial de artroplastia total de quadril (PAATQ), multidisciplinar, com consultas ambulatoriais e visitas domiciliares programadas para pacientes a serem submetidos à artroplastia total de quadril (ATQ), visando uma melhor abordagem por parte da equipe médica e de enfermagem e uma melhor orientação dos pacientes e familiares quanto ao procedimento cirúrgico. Este estudo transversal (piloto), com controle histórico aninhado a um ensaio clínico randomizado, tem por objetivo avaliar a factibilidade de implantação e a adesão, por parte das equipes médica e de enfermagem, à utilização deste protocolo. Secundariamente, visa determinar o impacto desta rotina no tempo de internação, na independência funcional do paciente e nos eventos clínicos da fase hospitalar, bem como avaliar a factibilidade das visitas domiciliares de enfermagem. Um total de 22 pacientes (9 homens e 13 mulheres) submetidos à ATQ no Hospital de Clínicas de Porto Alegre (Brasil), com média (dp) de idade de 58,86 (16,87), variando de 21 a 86 anos, foram incluídos no estudo. Os pacientes foram divididos em dois grupos  grupo 1 (n=12) e grupo 2 (n=10)  de acordo com aplicação ou não do PAATQ. No grupo 1, as principais comorbidades foram a hipertensão arterial sistêmica (HAS) (dois casos), o diabete mellitus (um caso); e o alcoolismo (um caso).No grupo 2, houve um caso de HAS. O tempo de permanência médio (dp) pós-operatório (DPO) foi de 5,2 e 7,5 dias para os grupos 1 e 2, respectivamente (p=0.0055). A adesão ao protocolo foi de 90% e 100% por parte das equipes médica e de enfermagem, respectivamente. Sete pacientes do grupo 1 conseguiram sentar fora do leito no 2o dia pós-operatório (PO), dois sentaram no 3o e nenhum foi incapaz de sair do leito. Todos deambularam com muletas um dia após sentarem. No grupo 2, todos os pacientes saíram do leito no 4o DPO. Em conclusão, o presente protocolo mostrou-se factível, tendo obtido ótima adesão por parte da equipe e propiciado redução do tempo de internação. O seguimento do programa determinará mais detalhadamente a sua eficácia e a factibilidade das visitas domiciliares. / The hip arthrosis is a degenerative joint disease occurring mainly in the elderly patients, a recently growing population. Rational measures are needed to better carry out the surgical procedures and to reduce cost for the health system, since almost two thirds of the costs are due to the admission period. Therefore, a global, multidisciplinary assistance program for total hip arthroplasty (THAAP), including ambulatory appointments and programmed home care by a nursing team, was established to guide patients and their relatives for the procedure. This is a pilot study for a randomized prospective clinical trial to assess the feasibility of the THAAP and to determine the protocol adherence by the medical and nurse team. Secondarily, it attempts to determine the impact of the program on admission period, patient functional autonomy and postoperative events, as well as to assess the feasibility of the programmed nursing home-care. A total of 22 patients (9 males, 13 females) with mean (SD) age of 58.86 (16.87) ranging from 21 to 86 years were included in the study. They were divided into two groups according whether they were (group 1, n=12) or were not (group 2, n=10) included in the THAAP. The main comorbidity for both groups were SAH (2 vs. 1), diabetes (1 vs. 0) and alcohol consumption (1 vs. 0), respectively. Mean (SD) postoperative (PO) period was significantly reduced (p=0.0055) in group 1; 5.2 (0.4) as compared to group 2; 7.5 (2.3). Adherence to the THAAP was 90% and 100% for doctors and nurses, respectively. Seven out of nine patients in group 1 were bed-seated on the second POD, two were seated on the third POD and none were bed-ridden. All of them were able to walk with crutches a day later. All patients in group 2 left bed on the fourth POD. In conclusion, the present protocol demonstrated to be feasible, team adherence was adequate and resulted in a reduced admission period. The progress of the program shall determine its efficacy and the feasibility of programmed nursing home care.
10

Comparação clínica, laboratorial e densitométrica de pacientes com coxartrose e fraturas do colo femoral

Spinelli, Leandro de Freitas January 2016 (has links)
Resumo não disponível.

Page generated in 0.0993 seconds