• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 11
  • 11
  • 11
  • 11
  • 8
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 348
  • 125
  • 118
  • 93
  • 89
  • 47
  • 43
  • 42
  • 41
  • 40
  • 39
  • 38
  • 37
  • 33
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação da infiltração da água no solo utilizando modelos determinísticos / Evaluation of the soil water Infiltration using deterministic models

Verena Benício de Oliveira 03 February 2015 (has links)
A infiltração é o processo pelo qual a água atravessa a superfície do solo, com grande importância para a hidrologia, irrigação e agricultura. À medida que a água infiltra, as camadas superiores do solo vão se umedecendo, alterando gradativamente o perfil de umidade. Sob condições de campo, a água que infiltra pode fluir tanto na vertical, como na horizontal, dependendo do tipo de solo e declividade do terreno. A taxa de infiltração da água no solo é afetada, principalmente, pelas características do solo que afetam a geometria de seu sistema poroso, como textura e estrutura, e pode ser determinada tanto no campo como em laboratório, por diferentes métodos. Com a intenção de otimizar a previsão da infiltração da água no solo, diversos modelos foram desenvolvidos, podendo ser classificados em três grupos: empíricos, semi-empíricos e com base física. O objetivo deste trabalho foi avaliar a infiltração de água em solos com diferentes texturas e comparar a qualidade do ajuste de diferentes modelos usualmente empregados. As curvas da taxa de infiltração e da infiltração acumulada foram determinadas em laboratório utilizando amostras de solo homogeneamente acondicionadas em colunas e comparadas pelos seguintes modelos: Kostiakov, Horton, Green & Ampt, e Philip. Dentre os solos estudados, o solo 3 (textura franco arenosa) foi o que apresentou a maior taxa de infiltração e a maior VIB, provavelmente devido a menor proporção de argila e maior presença de macroporos, facilitando a infiltração da água no solo. Dos modelos analisados, o de Kostiakov, seguido pelo de Philip, foram os que apresentaram em média os melhores valores estimados da taxa de infiltração quando comparados com os valores medidos em laboratório. O gráfico do avanço da frente de molhamento com a raiz quadrada do tempo de infiltração (horizontal) ajustou-se perfeitamente ao modelo de Philip. No que respeita a infiltração vertical tal gráfico foi semelhante ao da horizontal (linha reta), mas com maior inclinação. / Infiltration is the process in which the water passes through the soil surface, being of great importance for hydrology, irrigation and agriculture. As the water infiltrates, the soil water content profile will changing and the infiltrated water can flow vertically or horizontally, depending on the soil type and land slope. The soil water infiltration rate is mainly affected by soil properties that affect its porous geometry, such as texture and structure, and can be determined in the field and in the laboratory, using different methods. In order to optimize the prediction of the soil water infiltration, many different models have been developed and may be classified into three groups: empirical, semi-empirical and physically based. The objective of this study was to evaluate the water infiltration in soils with different textures and compare the quality of fit of the different used models. The infiltration rate curves and the cumulative infiltration curves were determined in the laboratory using soil samples homogeneously packed in column and compared by the following models: Kostiakov, Horton, Green & Ampt and Philip. Among the studied soils, the soil 3 (sandy loam texture) presented the highest infiltration rate and the highest basic infiltration rate, probably due to lower clay content and larger quantity of macropores, facilitating the water infiltration into the soil. Among the tested models, Kostiakov, followed by Philip, presented, on average, the best estimated values of the infiltration rate compared to the values measured in the laboratory. The front of the advancing wetting graph of the square root of the infiltration time (horizontal) well set to Philip model. With respect to this vertical graph infiltration was similar to the horizontal (straight line) but more inclined.
52

Avaliação da infiltração da água no solo utilizando modelos determinísticos / Evaluation of the soil water Infiltration using deterministic models

Oliveira, Verena Benício de 03 February 2015 (has links)
A infiltração é o processo pelo qual a água atravessa a superfície do solo, com grande importância para a hidrologia, irrigação e agricultura. À medida que a água infiltra, as camadas superiores do solo vão se umedecendo, alterando gradativamente o perfil de umidade. Sob condições de campo, a água que infiltra pode fluir tanto na vertical, como na horizontal, dependendo do tipo de solo e declividade do terreno. A taxa de infiltração da água no solo é afetada, principalmente, pelas características do solo que afetam a geometria de seu sistema poroso, como textura e estrutura, e pode ser determinada tanto no campo como em laboratório, por diferentes métodos. Com a intenção de otimizar a previsão da infiltração da água no solo, diversos modelos foram desenvolvidos, podendo ser classificados em três grupos: empíricos, semi-empíricos e com base física. O objetivo deste trabalho foi avaliar a infiltração de água em solos com diferentes texturas e comparar a qualidade do ajuste de diferentes modelos usualmente empregados. As curvas da taxa de infiltração e da infiltração acumulada foram determinadas em laboratório utilizando amostras de solo homogeneamente acondicionadas em colunas e comparadas pelos seguintes modelos: Kostiakov, Horton, Green & Ampt, e Philip. Dentre os solos estudados, o solo 3 (textura franco arenosa) foi o que apresentou a maior taxa de infiltração e a maior VIB, provavelmente devido a menor proporção de argila e maior presença de macroporos, facilitando a infiltração da água no solo. Dos modelos analisados, o de Kostiakov, seguido pelo de Philip, foram os que apresentaram em média os melhores valores estimados da taxa de infiltração quando comparados com os valores medidos em laboratório. O gráfico do avanço da frente de molhamento com a raiz quadrada do tempo de infiltração (horizontal) ajustou-se perfeitamente ao modelo de Philip. No que respeita a infiltração vertical tal gráfico foi semelhante ao da horizontal (linha reta), mas com maior inclinação. / Infiltration is the process in which the water passes through the soil surface, being of great importance for hydrology, irrigation and agriculture. As the water infiltrates, the soil water content profile will changing and the infiltrated water can flow vertically or horizontally, depending on the soil type and land slope. The soil water infiltration rate is mainly affected by soil properties that affect its porous geometry, such as texture and structure, and can be determined in the field and in the laboratory, using different methods. In order to optimize the prediction of the soil water infiltration, many different models have been developed and may be classified into three groups: empirical, semi-empirical and physically based. The objective of this study was to evaluate the water infiltration in soils with different textures and compare the quality of fit of the different used models. The infiltration rate curves and the cumulative infiltration curves were determined in the laboratory using soil samples homogeneously packed in column and compared by the following models: Kostiakov, Horton, Green & Ampt and Philip. Among the studied soils, the soil 3 (sandy loam texture) presented the highest infiltration rate and the highest basic infiltration rate, probably due to lower clay content and larger quantity of macropores, facilitating the water infiltration into the soil. Among the tested models, Kostiakov, followed by Philip, presented, on average, the best estimated values of the infiltration rate compared to the values measured in the laboratory. The front of the advancing wetting graph of the square root of the infiltration time (horizontal) well set to Philip model. With respect to this vertical graph infiltration was similar to the horizontal (straight line) but more inclined.
53

Síntese e processamento de compósitos  á base de alumina e zircônia com infiltração de fase vítrea para aplicações  odontológicas / SYNTHESIS AND CERAMIC PROCESSING OF ALUMINA AND ZIRCONIA BASED COMPOSITES INFILTRATED WITH GLASS PHASE FOR DENTAL APPLICATIONS

Duarte, Daniel Gomes 22 May 2009 (has links)
O interesse pelo emprego de materiais cerâmicos na odontologia surgiu, inicialmente, devido ao excelente resultado estético proporcionado pela similaridade aos dentes naturais. Entretanto, a fragilidade, inerente das cerâmicas tradicionais, era uma limitação que impossibilitava a utilização em condições em que o material fosse submetido à solicitação mecânica. Com o desenvolvimento de materiais à base de alumina e zircônia, os quais conciliam aspecto estético, biocompatibilidade e bom desempenho mecânico, o emprego de cerâmicas na fabricação de restaurações dentais começou a ser considerado. A incorporação de fase vítrea de reforço nestas cerâmicas tem como finalidade minimizar as taxas de retração e melhorar a adesão ao agente cimentante resinoso, necessário para união da infraestrutura cerâmica à estrutura dental remanescente. Comercialmente, esses materiais são conhecidos como sistemas In-Ceram®. Considerando-se que o aprimoramento dos métodos de síntese e de técnicas de processamento de pós cerâmicos é um dos fatores fundamentais para o bom desempenho desses materiais, o presente trabalho teve como objetivo o estudo de obtenção de cerâmicas à base de alumina e/ou zircônia estabilizada com 3 mol% de ítria com infiltração de fase vítrea de aluminoborossilicato de lantânio, partindo-se de insumos obtidos pela rota de coprecipitação de hidróxidos. Os pós sintetizados foram conformados por prensagem uniaxial e pré-sinterizados na faixa de temperatura entre 950 e 1650 ºC, visando a obtenção de corpos cerâmicos porosos. A incorporação da fase vítrea foi realizada pela impregnação do pó de aluminoborossilicato de lantânio, também preparado neste trabalho, e posterior tratamento térmico entre 1200 e 1400oC. As técnicas empregadas para caracterização dos pós incluíram: termogravimetria, difração de raios X, microscopia eletrônica de varredura e de transmissão, adsorção gasosa (BET) e espalhamento a laser. A sinterabilidade das amostras compactadas de alumina e/ou zircônia foi avaliada por dilatometria. As cerâmicas pré-sinterizadas foram avaliadas por medidas de densidade aparente pelo princípio de Archimedes, difração de raios X e observação da microestrutura por microscopia eletrônica de varredura. Testes de impressão Vickers e de citotoxicidade foram realizados após incorporação da fase vítrea. Tendo em vista a integridade estrutural, homogeneidade da microestrutura, elevados valores de tenacidade à fratura (3,6 4,9 MPa.m1/2) e a não citotoxicidade dos materiais preparados, constatou-se, neste trabalho, que as cerâmicas à base de alumina preparadas a partir de pós coprecipitados, são adequadas para obtenção de infraestruturas dentais com infiltração com fase vítrea. / The interest for the use of ceramic materials for dental applications started due to the good aesthetic appearance promoted by the similarity to natural teeth. However, the fragility of traditional ceramics was a limitation for their use in stress conditions. The development of alumina and zirconia based materials, that associate aesthetic results, biocompatibility and good mechanical behaviour, makes possible the employment of ceramics for fabrication of dental restorations. The incorporation of vitreous phase in these ceramics is an alternative to minimize the ceramic retraction and to improve the adhesion to resinbased cements, necessary for the union of ceramic frameworks to the remaining dental structure. In the dentistry field, alumina and zirconia ceramic infiltrated with glassy phase are represented commercially by the In-Ceram® systems. Considering that the improvement of powders synthesis routes and of techniques of ceramic processing contributes for good performance of these materials, the goal of the present work is the study of processing conditions of alumina and/or 3 mol% yttria-stabilized zirconia ceramics infiltrated with aluminum borosilicate lanthanum glass. The powders, synthesized by hydroxide coprecipitation route, were pressed by uniaxial compaction and pre-sintered at temperature range between 950 and 1650oC in order to obtain porous ceramics bodies. Vitreous phase incorporation was performed by impregnation of aluminum borosilicate lanthanum powder, also prepared in this work, followed by heat treatment between 1200 and 1400oC .Ceramic powders were characterized by thermogravimetry, X-ray diffraction, scanning and transmission electron microscopy, gaseous adsorption (BET) and laser diffraction. Sinterability of alumina and /or stabilized zirconia green pellets was evaluated by dilatometry. Pre-sintered ceramics were characterized by apparent density measurements (Archimedes method), X-ray diffraction and scanning electron microscopy. Vickers impression tests and citotoxicity essays were performed after glass phase incorporation. Considering the structural integrity of samples, homogeneity of microstrutures, high fracture toughness values (3.6 4.9 MPa.m1/2) and no citotoxity effects, it was verified that alumina based ceramics, prepared from coprecipitated powders, are adequate for production of dental frameworks infiltrated by vitreous phase.
54

Síntese e processamento de compósitos  á base de alumina e zircônia com infiltração de fase vítrea para aplicações  odontológicas / SYNTHESIS AND CERAMIC PROCESSING OF ALUMINA AND ZIRCONIA BASED COMPOSITES INFILTRATED WITH GLASS PHASE FOR DENTAL APPLICATIONS

Daniel Gomes Duarte 22 May 2009 (has links)
O interesse pelo emprego de materiais cerâmicos na odontologia surgiu, inicialmente, devido ao excelente resultado estético proporcionado pela similaridade aos dentes naturais. Entretanto, a fragilidade, inerente das cerâmicas tradicionais, era uma limitação que impossibilitava a utilização em condições em que o material fosse submetido à solicitação mecânica. Com o desenvolvimento de materiais à base de alumina e zircônia, os quais conciliam aspecto estético, biocompatibilidade e bom desempenho mecânico, o emprego de cerâmicas na fabricação de restaurações dentais começou a ser considerado. A incorporação de fase vítrea de reforço nestas cerâmicas tem como finalidade minimizar as taxas de retração e melhorar a adesão ao agente cimentante resinoso, necessário para união da infraestrutura cerâmica à estrutura dental remanescente. Comercialmente, esses materiais são conhecidos como sistemas In-Ceram®. Considerando-se que o aprimoramento dos métodos de síntese e de técnicas de processamento de pós cerâmicos é um dos fatores fundamentais para o bom desempenho desses materiais, o presente trabalho teve como objetivo o estudo de obtenção de cerâmicas à base de alumina e/ou zircônia estabilizada com 3 mol% de ítria com infiltração de fase vítrea de aluminoborossilicato de lantânio, partindo-se de insumos obtidos pela rota de coprecipitação de hidróxidos. Os pós sintetizados foram conformados por prensagem uniaxial e pré-sinterizados na faixa de temperatura entre 950 e 1650 ºC, visando a obtenção de corpos cerâmicos porosos. A incorporação da fase vítrea foi realizada pela impregnação do pó de aluminoborossilicato de lantânio, também preparado neste trabalho, e posterior tratamento térmico entre 1200 e 1400oC. As técnicas empregadas para caracterização dos pós incluíram: termogravimetria, difração de raios X, microscopia eletrônica de varredura e de transmissão, adsorção gasosa (BET) e espalhamento a laser. A sinterabilidade das amostras compactadas de alumina e/ou zircônia foi avaliada por dilatometria. As cerâmicas pré-sinterizadas foram avaliadas por medidas de densidade aparente pelo princípio de Archimedes, difração de raios X e observação da microestrutura por microscopia eletrônica de varredura. Testes de impressão Vickers e de citotoxicidade foram realizados após incorporação da fase vítrea. Tendo em vista a integridade estrutural, homogeneidade da microestrutura, elevados valores de tenacidade à fratura (3,6 4,9 MPa.m1/2) e a não citotoxicidade dos materiais preparados, constatou-se, neste trabalho, que as cerâmicas à base de alumina preparadas a partir de pós coprecipitados, são adequadas para obtenção de infraestruturas dentais com infiltração com fase vítrea. / The interest for the use of ceramic materials for dental applications started due to the good aesthetic appearance promoted by the similarity to natural teeth. However, the fragility of traditional ceramics was a limitation for their use in stress conditions. The development of alumina and zirconia based materials, that associate aesthetic results, biocompatibility and good mechanical behaviour, makes possible the employment of ceramics for fabrication of dental restorations. The incorporation of vitreous phase in these ceramics is an alternative to minimize the ceramic retraction and to improve the adhesion to resinbased cements, necessary for the union of ceramic frameworks to the remaining dental structure. In the dentistry field, alumina and zirconia ceramic infiltrated with glassy phase are represented commercially by the In-Ceram® systems. Considering that the improvement of powders synthesis routes and of techniques of ceramic processing contributes for good performance of these materials, the goal of the present work is the study of processing conditions of alumina and/or 3 mol% yttria-stabilized zirconia ceramics infiltrated with aluminum borosilicate lanthanum glass. The powders, synthesized by hydroxide coprecipitation route, were pressed by uniaxial compaction and pre-sintered at temperature range between 950 and 1650oC in order to obtain porous ceramics bodies. Vitreous phase incorporation was performed by impregnation of aluminum borosilicate lanthanum powder, also prepared in this work, followed by heat treatment between 1200 and 1400oC .Ceramic powders were characterized by thermogravimetry, X-ray diffraction, scanning and transmission electron microscopy, gaseous adsorption (BET) and laser diffraction. Sinterability of alumina and /or stabilized zirconia green pellets was evaluated by dilatometry. Pre-sintered ceramics were characterized by apparent density measurements (Archimedes method), X-ray diffraction and scanning electron microscopy. Vickers impression tests and citotoxicity essays were performed after glass phase incorporation. Considering the structural integrity of samples, homogeneity of microstrutures, high fracture toughness values (3.6 4.9 MPa.m1/2) and no citotoxity effects, it was verified that alumina based ceramics, prepared from coprecipitated powders, are adequate for production of dental frameworks infiltrated by vitreous phase.
55

Influência da interposição de bases na infiltração marginal em cavidades classe II (MOD), restauradas com resinas compostas para dentes posteriores.

Tapety, Celiane Mary Carneiro 06 March 2001 (has links)
Este estudo avaliou, in vitro, os níveis de microinfiltração em cavidades Classe II restauradas com três sistemas restauradores para dentes posteriores (P60/Single Bond-3M; Solitaire/Gluma One Bond-Kulzer e SureFil/Prime & Bond 2.1-Dentsply), com interposição de bases (uma resina de baixa viscosidade - Flow-It!/Jeneric Pentron; e um ionômero de vidro modificado por resina – Vitremer/3M); nos grupos controle nenhuma base foi utilizada. Em 90 dentes pré-molares humanos, extraídos por razões ortodônticas, foram confeccionadas cavidades de Classe II (MOD) padronizadas, com margens cervicais localizadas da seguinte forma: na caixa distal: 1mm aquém do limite amelo-cementário; na caixa mesial: 1mm além do limite amelo-cementário. Os dentes foram divididos em 9 grupos de 10 espécimes, como a seguir descritos: grupos I, II e III: receberam Flow-It! como base, nas paredes de fundo (axial e pulpar) e circundante (gengival) e foram restaurados com P60, Solitaire e SureFil, respectivamente; grupos IV, V e VI: foram apenas restaurados com as mesmas resinas (P60, Solitaire e SureFil), respectivamente: grupos VII, VIII e IX: receberam Vitremer como base e foram restaurados com P60, Solitaire e SureFil, respectivamente. As bases foram mantidas na parede gengival ao nível da junção amelo-dentinária, na caixa distal, e a 1mm do cavo-superficial, na caixa mesial. Passadas 24 horas da confecção das restaurações, estas foram submetidas a estresse mecânico (1-17kg, 10x a cada dia/7 dias). Após esse tempo, com as superfícies dentárias devidamente protegidas com esmalte para unhas, os espécimes foram armazenados em fuccina básica por 24 horas. Em seguida, foram lavados em água corrente, também por 24 horas. Foram incluídos em moldes de resina ortoftálica e seccionados, donde se obtiveram cortes de aproximadamente 0,8mm. Com um “scanner", foram tomadas imagens, previamente selecionadas com lupa (10x), da secção mais infiltrada de dente. A área de penetração do corante foi demarcada e calculada pelo programa ImageTool (UTHSCSA) e os resultados submetidos à análise de variância (ANOVA) a três critérios e à comparação individual de Tukey-Kramer. A análise dos resultados demonstrou que as margens em esmalte apresentaram menores áreas infiltradas, independentemente do material utilizado e das associações entre eles (p<0,05). A presença de base não resultou em redução da infiltração marginal significante para as resinas, P60 e SureFil, independente da margem avaliada (p>0,05). A resina Solitaire apresentou os maiores níveis de infiltração quando empregada sem a presença de base (p<0,05). Assim, concluise que a presença de base pode minimizar os níveis de infiltração, nas margens em esmalte e dentina, porém está na dependência do sistema restaurador empregado. / The purpose of this study was to determine the microleakage at cervical margins of class II (MOD) resin composite restorations using (P60/Single Bond©; Solitaire/Gluma One Bond6 e SureFil/Prime & Bond 2.1<), with and without Flow-It!J or Vitremer© bases. MOD cavity preparations were cut in 90 extracted, caries-free human premolars. One cervical margin was placed in enamel (1mm to the CEJ) and one in dentin (1mm below the CEJ). The teeth were randomly divided in 9 groups: groups I, II and III - a layer of a low viscosity resin composite (Flow It!) was placed on the pulpal, axial and gingival margins up to 1 mm before the cavosurface margin using their respective proprietary bonding agents and restored with P60, Solitaire or Surefil resin composite systems, respectively; groups IV, V and VI – were restored without placement of any base material with the mentioned restorative systems; groups VII, VIII and IX - a layer of a resin-modified glass-ionomer cement (Vitremer) was applied as described for groups I, II and III. The restored teeth were stored in water at 37oC and subjected to load cycles (1-17Kg x10/7 days) before being immersed in 0.5% basic fucsin for 24 h. The teeth were then washed and serially sectioned in a mesio-distal direction to obtain slices of the gingival margin interface. The slice with the highest degree of leakage as judged by a 10X microscope was selected and scanned image was analyzed by a digital image software (ImageTool, UTHSCSA) to calculate the area of leakage. Multivariable ANOVA showed that the highest degrees of leakage occurred at dentin margins regardless of the presence of base or type of resin filling (p<0.05). The presence of a base did not result in significant differences in the degree of leakage for both Surefil and P60 (p>0.05). Solitaire presented the highest degree of leakage when placed without a base material (p<0.05). The presence of a base material may decrease the degree of leakage, but this is dependent on the filling material.
56

Análise numérica da influência de chuvas extremas na estabilidade de taludes. / Numerical analysis of influence of extreme rainfall in slope stability.

Zambrana, Veroska Dueñas 13 November 2014 (has links)
Escorregamentos de taludes no Sudeste do Brasil são causados principalmente, pelo efeito da água proveniente das chuvas. Nos últimos anos, vem se incrementando o número de desastres naturais, ao passo são registradas mudanças climáticas, que podem exercer influência na ocorrência de chuvas extremas. Muitas encostas permanecem grande parte do ano com o solo em estado não saturado, porém variações nas condições ambientais podem ocasionar mudanças bruscas da sucção, reduzindo ou até mesmo eliminando-a e gerando pressões neutras positivas. A dissertação apresenta, um estudo sobre a influência das chuvas, consideradas extremas, no processo de infiltração e de este nos eventos de escorregamentos, considerados catastróficos pela sua dimensão, e que causaram prejuízos ambientais, econômicos e sociais no Brasil. Para o estudo foram selecionados dois eventos de escorregamentos translacionais rasos relativamente típicos, considerados catastróficos, um deles aconteceu na região da Serra de Cubatão em janeiro do ano 1985, e o outro na Região Serrana do Rio de Janeiro em janeiro de 2011. Estes dois eventos apresentaram características de precipitações e mecanismos de escorregamentos próprios, que permitem ilustrar os diferentes mecanismos atuantes em cada caso. / Landslide in southeastern Brazil, are mainly caused by the effect of water from rainfall in infiltration process, in recent years has been increasing the number of natural disasters, while climate change that may exercising influence on the occurrence of extreme rainfall are recorded . Many slopes remain a large part of the year with unsaturated soil condition; however, changes in environmental conditions can cause sudden changes of suction, reducing or even deleting it and generate positive pore pressures. This dissertation presents a study about the influence of rainfall, considered extreme in the infiltration process and this one in the events regarded by their size of catastrophic landslides, which caused environmental, economic and social losses in Brazil. For the study were selected two events of shallow translational landslides relatively typical, considered catastrophic, one of them occurred in the Serra de Cubatão region on January 1985 and the other in the mountainous region of Rio de Janeiro on January 2011. Both events exhibit characteristics of rainfall and sliding mechanisms themselves, allowing illustrate the different mechanisms active in each case.
57

Avaliação "in vitro" da microinfiltração marginal em cavidades de Classe V, restauradas com resinas compostas condensáveis, resina composta híbrida, resina composta modificada por poliácidos e ionômero de vidro modificado por resina

Nunes, Osvaldo Benoni da Cunha 09 November 2001 (has links)
A finalidade deste trabalho foi verificar o grau de infiltração marginal em cavidades classe V, vestibulares e linguais, em dentes pré-molares humanos extraídos por razões ortodônticas e restaurados com resina composta condensável, resina composta híbrida, resina composta modificada por poliácidos e ionômero de vidro modificado por resina. Foram utilizados 50 dentes livres de cáries, que após a coleta foram limpos e fixados em formalina tamponada a 10% e, a seguir, armazenados em água destilada. Foram realizadas cavidades classe V por vestibular e lingual com 3 mm de diâmetro e 1,5 mm de profundidade, e em seguida restaurados e agrupados segundo o material restaurador escolhido em : Grupo I: dentes restaurados com resina composta condensável Alert; Grupo II: dentes restaurados com resina composta condensável Solitaire; Grupo III: dentes restaurados com resina composta híbrida Z- 250 ; Grupo IV: dentes restaurados com compômero Dyract AP e Grupo V: dentes restaurados com ionômero de vidro Vitremer (grupo controle). Concluídas as restaurações os dentes foram imersos em água destilada a 37ºC por 24 horas; polidos com discos Sof-Lex e impermeabilizados com Araldite e esmalte para unhas, preservando-se 2 mm ao redor da restauração, sem impermeabilização. Uma vez secos, os dentes foram submetidos à ciclagem térmica com temperatura de 5ºC/ 55 º C, em um total de 200 ciclos, com 30 segundos em cada banho. Os dentes foram imersos em uma solução aquosa de azul de metileno a 2% por um período de 24 horas. Concluídos os procedimentos acima, os espécimes foram lavados e cortados longitudinalmente com disco diamantado, no sentido vestíbulo-lingual. Os dentes foram examinados com lupa com aumento de 7x e classificados segundo o grau de penetração máxima do corante, utilizando-se escores de 0 a 4, segundo o número de paredes infiltradas. A análise estatística aplicada aos resultados obtidos permitiu as seguintes conclusões: a resina composta Alert demonstrou menor infiltração marginal (P<0,05), seguida do Dyract AP, sendo que ambas comportaram-se estatisticamente melhor que os demais grupos. Não houve diferença estatística significante entre a resina Z-250 e o Vitremer. A resina composta Solitaire teve o pior desempenho quanto à infiltração marginal. / This study compares the marginal leakage of four restorative materials: condensable resin composites (Group I: Alert and Group II: Solitaire), hybrid resin composite (Group III: Z-250) and polyacid-modified resin composite (Group IV: Dyract). Vitremer (Group V), resin- modified glass ionomer was chosen as the control group. Fifty sound pre-molars extracted for orthodontic reasons were cleaned, fixed in 10% formalin and stored in destiled water. Class V restorations (diameter= 3mm, depth= 1,5mm) were prepared in the vestibular and lingual surfaces. Following restorations placement (N=100), the samples were immersed in destiled water for 24 hours at 37º C and polished with Sof-Lex discs. The samples were made impermeable (varnish) excluding 2 mm area around the restoration. The teeth were dried and submitted to 200 termic cicles (5ºC/55ºC) each one lasting 30 seconds. The samples were immersed in 2% methylene blue dye for 24 hours and sliced longitudinally (vestibular to lingual surfaces) with diamond disc. A 7-fold magnifying glass was used to classify the samples (0-4 score) according to maximum dye penetration level and number of infiltration sites . The difference was significant (P<0,05) for Group I: Alert and Group IV: Dyract. The other three groups showed non statistically significant results with the poorest performance by Solitaire.
58

Avaliação in vitro da infiltração de fluidos pela interface implante-pilar intermediário de três sistemas com conexão do tipo cone Morse e da capacidade de vedação de um material / In vitro evaluation of fluid penetration at the implant-abutment interface of three cone Morse systems and sealing ability of a material

Moraes, Flavia Maria Lopes de 27 September 2010 (has links)
A infiltração de fluido e bactérias nos espaços internos dos implantes foi observada em pilares intermediários parafusados, tanto em situações in vitro quanto in vivo devido à microfenda existente entre o implante e o pilar intermediário. Esse fato pode estar relacionado com a inflamação dos tecidos periimplantares e também com a produção de mau odor. O objetivo do presente estudo in vitro foi avaliar e comparar a ocorrência de infiltração de fluidos pela interface implante-pilar intermediário em três sistemas de implante com conexão do tipo cone Morse, e a capacidade de vedação de um adesivo anaeróbico, utilizando o radioisótopo Tecnécio-99m como marcador. Na primeira etapa, dez conjuntos implante-pilar intermediário de cada sistema foram imersos em solução contendo esse marcador, após a aplicação do torque recomendado pelo fabricante, e foram mantidos em pressão constante de 2 atm por um minuto. Na segunda etapa, um adesivo anaeróbico foi aplicado no pilar intermediário antes do mesmo ser parafusado ao seu respectivo implante. Após a aplicação da pressão, o infiltrado presente no interior dos implantes foi coletado com pontas de papel. Esse material foi depositado em tubos de ensaio para posterior leitura da radioatividade presente. A infiltração de fluido pela interface implante-pilar intermediário mostrou ser um fenômeno mensurável em todas as amostras dos três sistemas de implante com conexão do tipo cone Morse testados. A quantidade de infiltrado variou entre os sistemas e entre as amostras. A inconstância das amostras foi observada em todos os sistemas, no entanto, foi observado que o valor de infiltrado encontrado no Grupo 1 foi significantemente maior (p<0,05) do que o encontrado no Grupo 2, e não houve diferença estatística significante entre os Grupos 1 e 3, e entre os Grupos 2 e 3. Também foi observado que, com o uso do adesivo anaeróbico, os sistemas apresentaram diminuição da quantidade de infiltrado, sendo que a análise estatística dos valores obtidos com e sem o seu uso, mostraram significância a 1%. Além disso, com o uso do adesivo anaeróbico os três sistemas de implante testados passaram a ter comportamento semelhante, não tendo sido encontrada diferença estatística significante entre eles (p=0,5451). Considerando os limites deste estudo, pode-se concluir que os três sistemas de implante com conexão do tipo cone Morse testados permitiram a passagem de fluido do meio externo para o interior dos implantes, e que o material testado não foi capaz de impedir a penetração de fluido, apesar de ter reduzido significantemente a quantidade de infiltrado em todos os sistemas. / It has been observed that in implants with screw-retained abutments, in in vitro as well as in vivo conditions, bacteria and fluids can penetrate the inner implant space as consequence of an existing microgap at the implant-abutment interface. This fact can be related to peri-implant tissue inflammation and malodor. The aim of the present study was to evaluate and compare the occurrence of fluid penetration throught implant-abutment interface in three cone Morse implant systems and sealing ability of an anaerobic adhesive using a radioisotope as trace. In the first phase, ten implant-abutment sets of each system were immersed in a solution with radioisotope, after manufacture recommended torque application. All assemblies were kept in a constant pressure of 2 atm for one minute. In the second phase, an anaerobic adhesive was applied before the abutments been torque-tightened to the same implant. After the pressure application, material inside implant bodies was colleted using a paper cone that was transferred to tubes for posterior verification of radioactivity. Fluid penetration at the implant-abutment interface was seen to be a recordable phenomenon in each assembly of the three cone Morse systems tested in this study. The quantity of infiltrated varied between systems and assemblies. The variable of the samples was observed in all systems, however, it was noted that the value of infiltrate found in Group 1 was significantly higher than that found in Group 2, and there was no statistical significant difference between the groups 1 and 3, and between groups 2 and 3. It was also noted that, using the adhesive anaerobic, the implant systems showed reduce infiltrate, and statistical analysis presented significance to 1%. Moreover, with the use of anaerobic adhesive, all three implant systems tested presented similar pattern, and no significant statistical difference was found (p=0,5451). Considering the limits of this study, the following conclusions can be drawn: the three cone Morse implant systems tested allowed the passage of fluid from external to the inside of the implants, and that the material tested was not capable of preventing the fluid penetration, despite having reduced significantly the amount of infiltrate in all systems.
59

Influência da irradiação com lasers de alta potência na microinfiltração bacteriana e fúngica em dentes humanos retrobturados com MTA / High power lasers Influence in bacterial and fungical microleakage in MTA retrofills

Aun, Carmo Antonio 02 April 2008 (has links)
Este estudo experimental avaliou, in vitro, a microinfiltração de E. faecalis e C. albicans em raízes cujas superfícies apicais ressectadas e retropreparadas para obturação retrógrada sofreram irradiação dos lasers Nd:YAG, Diodo 810 nm e Er,Cr:YSGG, e posteriormente retrobturadas com MTA. Setenta raízes foram instrumentadas, obturadas endodonticamente, apicectomizadas e receberam retropreparos com pontas ultra-sônicas diamantadas e lisas na potência média. A divisão dos espécimes se deu de acordo com o laser utilizado e o tipo de microorganismo. Os grupos G1 e G5 não foram irradiados, G2 e G6 irradiados com Nd:YAG, G3 e G7 com Diodo e G4 e G8 com Er,Cr:YSGG (n = 8). Foram utilizados controles positivo (n = 3) e negativo (n = 3). Todos os procedimentos operatórios foram realizados com um dispositivo de simulação de dificuldades operatórias. Após a impermeabilização, colagem das raízes em tubos preparados, esterilização e retrobturação com MTA branco, o sistema de câmaras superior, contendo o inóculo de microorganismos, e inferior, contendo meio esterilizado foi montado em contato com o ápice. Os grupos G1 a G4 foram inoculados com E. faecalis, e os grupos G5 a G8 com C. albicans. A troca de meio na câmara superior se deu a cada 3 dias e a verificação da turvação do meio inferior era diária, por um período de 60 dias. Ao final, os resultados indicaram que: o controle positivo apresentou 100% de microinfiltração, o controle negativo não microinfiltrou e os grupos experimentais apresentaram padrões de microinfiltração que variaram entre 50% (G1) e 100% (G2) de microinfiltração, onde 68,75% do total de espécimes microinfiltraram. Não houve diferença estatística significativa entre os grupos aplicando-se os testes Exato de Fischer e Kruskal-Wallis (p > 0,05) em nenhuma interação. Pode-se concluir que o tratamento das retrocavidades e superfície apical ressectada, com os lasers utilizados neste estudo, não alterou o padrão de microinfiltração das retrobturações com MTA frente a E. faecalis e C. albicans. O tipo de microorganismo utilizado também não alterou a quantidade de espécimes microinfiltrados. / This in vitro experimental study evaluated the microleakage of E. faecalis and C. albicans in roots whose ressected apical surfaces and retrocavities had suffered irradiation from Nd:YAG, Diode 810 nm and Er,Cr:YSGG lasers, and later retrofiled with MTA. Seventy roots had been prepared, obturated, had suffered apicoectomy and were retroprepared with diamond and conventional ultra-sonic tips in the average power. The division of specimens was in accordance with the used laser and the type of microorganism. The groups G1 and G5 had not been irradiated, G2 and G6 irradiated with Nd:YAG, G3 and G7 with Diode and G4 and G8 with Er, Cr:YSGG (n = 8). Positive (n = 3) and negative (n = 3) controls had been used. All procedures executed until this point had been carried inside an access difficulties simulation device. After the waterproofing, attachment of the roots in prepared tubes and sterilization, the retrofillings were made using white MTA. The superior chambers were inoculated with the microorganisms and inferior chambers were completed with sterile culture broth in contact with the root tip. The G1, G2, G3 and G4 groups had been inoculated with E. faecalis and the rest of the groups with C. albicans. The contaminated broths of the upper chambers were exchanged each 3 days and for 60 days the verification of the turbidity in the inferior chambers was evaluated daily. At the end, the results had indicated that: the positive control had 100% microleakage, the negative control none and the experimental groups had presented microleakege patterns that range from 50% (G1) to 100% (G2), with a total of 68.75% of all specimens presenting microleakage. Applying the Exact Fischer test and Kruskal-Wallis test (p > 0,05), no significant statistical difference between the groups were observed in any interaction. It can be concluded that the treatment of the retrocavities and ressected apical surface, with the lasers used in this study, did not modify the rate of E. faecalis and C. albicans microleakage in MTA retrofillings. Also the type of used microorganism did not seem to modify the amount of microleakage in the specimens.
60

Estudo in vitro de um material para selamento da interface implante-intermediário do tipo minipilar cônico em implantes de hexágono externo, hexágono interno e cone morse / In vitro sealing of a material of implant-abutment interface of mini conical pillar: inimplant external hexagon, internal hexagon and Morse taper

Nascimento, Mônica Lôbo do 08 May 2012 (has links)
A micro infiltração de fluidos bucais e bactérias na interface implante e o intermediário são discutidos na literatura através de várias pesquisas pontuando e determinando que o espaço existente entre os componentes e as conexões dos implantes, chamados de GAP, que parece ser a fonte da infiltração de microorganismos, quer a partir de meio externo para meio interno ou vice versa, resultando em reações inflamatórias nos tecidos periodontais. Portanto, este estudo teve como objetivo analisar um método para evitar e ou pelo menos diminuir micro infiltração na interface implante-intermediário utilizando um material de vedação chamado Loctite® 222 (Henkel Ltda). Este é um material monocomponente, anaeróbico, tixotrópico, de baixa resistência à desmontagem sendo utilizado industrialmente para ajustar os parafusos. Os implantes testados neste estudo foram de três diferentes sistemas de conexão protética: hexágono externo (n = 10), hexágono interno (n = 10) e cone morse (n = 10) e estes foram todos fabricados pela mesma empresa (SIN - Sistema de Implantes). Inicialmente, esses implantes foram utilizados como grupo controle, não recebendo a aplicação do selante na área de conexão. Mini intermediários cônicos foram sentados sobre os corpos dos implantes e o torque foi aplicado seguindo recomendação dos fabricantes. Cada implante foi imerso em um criotubo de 2ml contendo 1,5 ml de BHI estéril. Todos foram inoculados com 250l de Enterecoccus faecalis (ATCC - 29212) no interior do criotubo. Os implantes foram limpos, esterilizados e divididos em 3 grupos testes. Uma fina camada do selante foi aplicada com microbrush sobre a área de conexão antes de encaixar os pilares e logo foi aplicado o torque conforme as recomendações do fabricante. Períodos de avaliação, de 7, 14, 21, 35, 49 e 63 dias foram realizados para analisar a presença de micro infiltração do meio interno dos implantes, seguindo regulamentações específicas no fluxo laminar. Os resultados mostraram a eficácia do material selante quando se compara o grupo controle com os grupos testes. Uma eficácia de 100% foi encontrada para todos os sistemas de implantes estudados, o hexágono externo, hexágono interno e cone morse. / Microbial and fluidic leakage in the implant-abutment interface are shown in literature through a variety of studies, accusing the space that exists between the components of the implant, called \"GAP\", which seems to be the source of the microorganism infiltration, either from the external to the internal environment or the inverse, resulting in inflammatory reactions of the periodontal tissues. Therefore, this study aimed to analyze a method to avoid or at least reduce microleakage at the implant-abutment interface by using a sealing material named Loctite ® 222 (Henkel Ltda). This is a single component, anaerobic, thixotropic, lowstrength threadlocker material industrially used to adjust screws. The implants tested in this study were of three different implant-abutment systems: external hexagon (n=10), internal hexagon (n=10) and morse cone connection (n=10) and these were all manufactured by the same company (SIN - Implant System). Initially, these implants were used as the control group, not receiving the sealant application at the connection area. Mini conical abutments were seated over the implant bodies and torque-tightened to 20 Ncm. Each implant was immersed in a 2ml cryotube containing 1.5 ml of sterile BHI. All implants were inoculated with 250l of Enterecoccus faecalis (ATCC - 29212) inside the cryotube. The same implants were then cleaned, sterilized and divided into 3 test groups. A thin layer of the sealant was applied on the connection area before seating the abutments and proceeding as described before. Evaluation periods of 7, 14, 21, 35, 49 and 63 days were performed to analyze the presence of external contamination of the internal environment, following specific regulations in laminar flow. The results showed the effectiveness of the sealant material when comparing the control group to the test groups. An efficacy of 100% was found for all implant systems studied, the external hexagon, internal hexagon and Morse cone connection.

Page generated in 0.1754 seconds