• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 11
  • 11
  • 11
  • 11
  • 8
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 348
  • 125
  • 118
  • 93
  • 89
  • 47
  • 43
  • 42
  • 41
  • 40
  • 39
  • 38
  • 37
  • 33
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influência da deposição de filmes de carbono tipo diamante na infiltração bacteriana pela interface entre implantes e pilares protéticos /

Cardoso, Mayra. January 2013 (has links)
Orientador: Lafayette Nogueira Junior / Co-orientador: Argemiro Soares da Silva Sobrinho / Banca: Cristiane Yumi Koga-Ito / Banca: Luiz Carlos Santiago da Costa / Banca: Marcos Massi / Banca : Nelson Luiz de Macedo / Resumo: O estudo avaliou a influência da deposição de filmes de DLC na infiltração bacteriana pela interface entre pilares protéticos e implantes de hexágono externo (HE) e interno (HI). Também avaliou a aderência microbiana a estes filmes, depositados sobre titânio. A deposição dos filmes foi realizada por PECVD (Deposição Química a Vapor Assistida por Plasma), e sua caracterização foi feita pelas análises de perfilometria mecânica, espectroscopia Raman, rugosidade, análise tribológica, espectroscopia de energia dispersiva e ângulo de contato. Para avaliação da aderência microbiana, lâminas de titânio (N=45; n=15) foram divididas em três grupos: (1) sem filme (controle); (2) com filme de DLC; e (3) com filme de DLC dopado com prata (DLC-Ag). Elas foram suspensas em poços contendo saliva-glicerol e caldo de cultura. Após 48 h de incubação, elas foram agitadas em ultrassom e a suspensão resultante foi diluída e semeada em placas para contagem de microrganismos. Para avaliação da infiltração bacteriana pela interface implante/pilar, conjuntos de implantes e pilares HE e HI (N=180; n=30) foram divididos de acordo com o tratamento da base do pilar: (1) nenhum tratamento (controle); (2) deposição de filme de DLC; e (3) deposição de filme de DLC-Ag. Sob condições assépticas, foi inoculado 1 μL de suspensão de Enterococcus faecalis no interior dos implantes, e os pilares foram parafusados com 20 Ncm. Os conjuntos foram testados para contaminação externa imediata, suspensos em tubos de ensaio contendo caldo de cultura estéril, e acompanhados por cinco dias. A turvação do caldo indicou infiltração bacteriana. Ao final do período, os pilares foram desparafusados e o conteúdo interno dos implantes foi coletado com cone de papel e semeado em placas de Petri. Estas foram levadas a estufa bacteriológica por 24 h para verificação da viabilidade bacteriana.... / Abstract: This study evaluated the influence of DLC films on bacterial leakage through the interface between abutments and dental implants of external hexagon (HE) and internal hexagon (HI). It also evaluated microbial adhesion to these films deposited on titanium. The deposition of the films was performed by PECVD (Plasma Enhanced Chemical Vapor Deposition), and its characterizations were done by mechanical profilometry, Raman spectroscopy, surface roughness, tribological analysis, energy dispersive spectroscopy and contact angle. To evaluate the microbial adhesion, titanium blades (N=45, n=15) were divided into three groups: (1) without film (control), (2) with DLC film, and (3) with DLC film doped with silver (Ag-DLC). They were suspended in wells containing saliva-glycerol broth. After 48 h incubation they were ultrasonicated and the resulting suspension was diluted and plated for CFU counting. For evaluation of bacterial leakage through implant/abutment interface, sets of implants and abutments (N=180, n=30) were divided according to the treatment of the base of the abutment: (1) no treatment (control); (2) deposition of DLC film, and (3) deposition of Ag-DLC film. Under aseptic conditions, 1 μL of Enterococcus faecalis was inoculated inside the implants, and abutments were tightened to 20 Ncm. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed for five days. The turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper cone and seeded in Petri dishes. These were incubated for 24 h for assessment of bacterial viability and CFU counting. The roughness and log10CFU/mL data were analyzed by analysis of variance. The bacterial leakage was analyzed by Chi-square test, Fisher exact test, Kaplan-Meier and .... / Doutor
12

Avaliação da classificação hidrologica do solo para a determinação do excesso de chuva do metodo do serviço de conservação do solo dos Estados Unidos

Sartori, Aderson 03 August 2018 (has links)
Orientador : Abel Maia Genovez / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-03T22:16:59Z (GMT). No. of bitstreams: 1 Sartori_Aderson_M.pdf: 1834880 bytes, checksum: b460f45424ea0d48e9f810202d806fba (MD5) Previous issue date: 2004 / Mestrado
13

Modelo computacional para simular a equação da velocidade de infiltração da água no solo / not available

Marques Junior, Sergio 30 April 1993 (has links)
O objetivo do trabalho foi desenvolver um modelo de simulação capaz de estimar a equação de velocidade de infiltração da água no solo o procedimento matemático de estimativa foi baseado na técnica das diferenças finitas, no qual estima-se o volume de água que atravessa uma camada imaginária num dado intervalo de tempo. Os parâmetros necessários à simulação foram: umidade inicial, curva de retenção, condutividade hidráulica em meio saturado, densidade global e carga hidráulica. A aferição do modelo foi realizada a partir de testes de infiltração com colunas verticais de solo utilizando-se solos pertencentes a duas classes texturais distintas. Os parâmetros que mais influenciaram na simulação das equações de infiltração foram o intervalo de tempo e a condutividade hidráulica em meio saturado. Dentro do universo amostrado, não se verificou influência significativa do parâmetro volume hipotético da camada nas estimativas das equações de velocidade de infiltração / not available
14

Avaliação "in vitro" da infiltração marginal em função da configuração cavitária e de materiais restauradores estéticos

Lopes, Lawrence Gonzaga 15 December 2000 (has links)
O objetivo deste trabalho foi avaliar a infiltração marginal de restaurações cervicais em função do fator de configuração cavitária (FC) e de quatro materiais restauradores estéticos. Cavidades convencionais com FC=5, e em forma de “pires" com FC<5 foram realizadas, respectivamente, nas faces distais e mesiais de 60 prémolares recém-extraídos. Para a primeira cavidade, utilizou-se uma ponta diamantada troncocônica com dimensões especiais (2,9 mm x 2,5 mm (base menor) x 1,5 mm de profundidade). A cavidade em forma de “pires" apresentou dimensões proporcionais ao diâmetro da ponta diamantada esférica n.3018 (2,9 mm) e, também, com profundidade de 1,5 mm, sendo que as margens das cavidades localizaram-se em esmalte e cemento/dentina. Os seguintes grupos foram estabelecidos: G1 (Z100/Single Bond-3M), G2 (Freedom/Stae–SDI), G3 (Vitremer/Primer–3M) e G4 (Durafill/Durafill Bond-Kulzer). Os sistemas restauradores foram aplicados conforme as orientações de cada fabricante. A termociclagem dos espécimes compreendeu 10 ciclos/dia nas temperaturas de 37ºC, 5ºC e 55ºC, com permanência de 1,5 minuto. Esses procedimentos foram repetidos pelo período de sete dias, totalizando 70 ciclos, sendo que no último dia a ciclagem foi feita em solução aquosa tamponada de azul de metileno a 2%. Em seguida os espécimes foram seccionados, fotografados em estereomicroscópio, com aumento de 16X, e depois avaliados por dois examinadores pela projeção das fotografias. Os valores foram submetidos à análise de Kruskal-Wallis a um critério, Dunn; Wilcoxon; e Friedman, Student-Newman-Keuls. As médias dos escores de infiltração observados na cavidade convencional e naquela em forma de “pires" foram, respectivamente: G1- 0,66 / 0,46; G2- 0,92 / 0,69; G3- 1,8 / 1,86; G4- 3,54 / 2,3. Portanto, o fator de configuração cavitária não exerceu, de maneira geral, influência significativa para os diferentes sistemas restauradores. Com exceção do sistema Durafill/Durafill Bond, que apresentou os maiores graus de infiltração marginal, os demais materiais comportaram-se de forma semelhante. / The aim of this work was to evaluate the cervical restorations marginal leakage in regard with the cavity configuration factor (CF) and four esthetic restorative materials. Conventional cervical cavities with CF=5 and other "Saucer"- like cavities with CF<5, were carried out on the distal and mesial surfaces, in 60 freshly extracted premolars. For the first cavity, a trunk-conic diamond bur with special dimensions (2.9mm x 2.5 mm x 1.5mm) was used. The "Saucer"-like cavity had dimensions proportional to the diamond bur diameter #3018 (2.9 mm), and the depth determined in 1.5 mm. The cavities margins were set either in cement/dentin or enamel. Some groups were established: G1 (Z100/Single Bond-3M), G2 (Freedom/Stae-SDI), G3 (Vitremer/Primer-3M) and G4 (Durafill/Durafill Bond). These restorative systems were used according to their manufacters' directions. The specimens were submitted to 10 cycles/day at the temperatures 37ºC, 5ºC and 55ºC, exposing the teeth to 1.5 minutes. Seven thermocyclings (7 days) were performed, totalizing 70 cycles, but at the last one, the thermocycling was done in 2% buffered methylene blue aqueous solution. The specimens were thereafter sectioned, photographed under a stereomicroscope at 16X magnification, and the obtained photographs were assessed by two trained examiners. The results were evaluated through the Kruskal-Wallis one way analysis, Dunn's multiple comparisons method; Wilcoxon; and Friedman, Student-Newman-Keuls methods. The means scores of the marginal leakage concerning the conventional cavity and the "Saucer"-like cavity, were respectively: G1- 0.66 / 0.46; G2- 0.92 / 0.69; G3- 1.8 / 1.86; G4- 3.54 / 2.3. Hence, the cavity configuration factor didn’t have, at all, a significant influence to the different restorative materials. Except for the Durafill/Durafill Bond system, that presented the greatest degrees of marginal leakage, the other restorative materials had the same behavior.
15

Infiltração coronária em obturações de canais radiculares realizadas com diferentes cimentos endodônticos resinosos: avaliação pelo método da filtração de fluído

Silva Neto, Ulisses Xavier da 01 July 2005 (has links)
Foi analisada a infiltração coronária, in vitro, de diferentes cimentos endodônticos resinosos (AH26, AH Plus, EndoREZ e o cimento experimental MBP). Utilizaram-se sessenta e quatro dentes pré-molares inferiores humanos unirradiculados extraídos, que tiveram suas coroas eliminadas, padronizando o comprimento das raízes em 14 mm. Os canais radiculares foram instrumentados por meio da técnica escalonada regressiva, as raízes foram impermeabilizadas com duas camadas de esmalte para unhas, exceto na região do forame apical e, então, foram divididas em quatro grupos de 15 espécimes de acordo com o cimento obturador utilizado. Em seguida, os canais foram obturados pela técnica do cone único de guta-percha. Quatro raízes foram utilizadas como controle, sendo 2 controles positivo e 2 controles negativo. Posteriormente, os espécimes foram mantidos por 15 dias em estufa a 37°C e 100% de umidade. O método da filtração de fluido foi utilizado para a avaliação quantitativa da infiltração coronária. A infiltração foi mensurada pela movimentação de uma bolha de ar dentro de um capilar de vidro de 25 µl e 65 mm, conectado às raízes. As medições foram realizadas a cada 2 minutos em um intervalo de 8 minutos. A qualidade do selamento, em cada espécime, foi medida após 15, 30 e 60 dias e os resultados submetidos à análise estatística pelos testes ANOVA e Tukey HSD. Com relação ao fator tempo, concluiu-se que não houve diferença no grau de infiltração aos 15 e 30 dias, apresentando uma redução estatisticamente significante aos 60 dias. Aos 15 dias os cimentos AH Plus e MBP produziram menores médias de infiltração que os cimentos AH26 e EndoREZ (p<0,05). Aos 30 dias o cimento AH26 apresentou as maiores médias de infiltração quando comparado aos outros cimentos (p<0,05). Aos 60 dias o cimento MBP e AH Plus apresentaram as menores médias de infiltração, com diferença significante em relação ao cimento EndoREZ (p<0,05). / Foi analisada a infiltração coronária, in vitro, de diferentes cimentos endodônticos resinosos (AH26, AH Plus, EndoREZ e o cimento experimental MBP). Utilizaram-se sessenta e quatro dentes pré-molares inferiores humanos unirradiculados extraídos, que tiveram suas coroas eliminadas, padronizando o comprimento das raízes em 14 mm. Os canais radiculares foram instrumentados por meio da técnica escalonada regressiva, as raízes foram impermeabilizadas com duas camadas de esmalte para unhas, exceto na região do forame apical e, então, foram divididas em quatro grupos de 15 espécimes de acordo com o cimento obturador utilizado. Em seguida, os canais foram obturados pela técnica do cone único de guta-percha. Quatro raízes foram utilizadas como controle, sendo 2 controles positivo e 2 controles negativo. Posteriormente, os espécimes foram mantidos por 15 dias em estufa a 37°C e 100% de umidade. O método da filtração de fluido foi utilizado para a avaliação quantitativa da infiltração coronária. A infiltração foi mensurada pela movimentação de uma bolha de ar dentro de um capilar de vidro de 25 µl e 65 mm, conectado às raízes. As medições foram realizadas a cada 2 minutos em um intervalo de 8 minutos. A qualidade do selamento, em cada espécime, foi medida após 15, 30 e 60 dias e os resultados submetidos à análise estatística pelos testes ANOVA e Tukey HSD. Com relação ao fator tempo, concluiu-se que não houve diferença no grau de infiltração aos 15 e 30 dias, apresentando uma redução estatisticamente significante aos 60 dias. Aos 15 dias os cimentos AH Plus e MBP produziram menores médias de infiltração que os cimentos AH26 e EndoREZ (p<0,05). Aos 30 dias o cimento AH26 apresentou as maiores médias de infiltração quando comparado aos outros cimentos (p<0,05). Aos 60 dias o cimento MBP e AH Plus apresentaram as menores médias de infiltração, com diferença significante em relação ao cimento EndoREZ (p<0,05).
16

Infiltração marginal em restaurações classe V de resina composta: influência da base e da técnica de fotoativação / Marginal leakage in class V resin composite restorations: influence of the liner and the curing technique

Svizero, Nádia da Rocha 22 May 2003 (has links)
Avaliou-se a infiltração marginal em cavidades classe V restauradas com resina composta, utilizando-se diferentes bases de cimentos de ionômero de vidro e diferentes técnicas de fotoativação. As cavidades foram confeccionadas na face vestibular da raiz de 120 dentes bovinos, apresentando 4mm de altura, 3mm de largura e 1,5mm de profundidade. Os dentes foram divididos em 12 grupos, de acordo com o tipo de base (cimento de ionômero de vidro modificado por resina ou convencional) e com a técnica de fotoativação (convencional, rampa, pulso e alta intensidade). Grupos 1, 4, 7 e 10- Single Bond + Z100; grupos 2, 5, 8 e 11- CIVMR (Vitrebond) + Single Bond + Z100; grupos 3, 6, 9 e 12- CIV convencional (Ketac Bond) + Single Bond + Z100. Os grupos 1, 2 e 3 foram fotoativados pela técnica convencional e os demais grupos pelas técnicas em rampa (4, 5 e 6), por pulso (7, 8, 9) e alta intensidade (10, 11, 12). A base de cimento de ionômero de vidro apresentou-se com 0,5mm de espessura e a resina composta foi inserida em um único incremento. As técnicas de fotoativação, com diferentes intensidades de luz, foram empregadas da seguinte forma: 450mW/cm2 por 40s (convencional), 100 a 800mW/cm2 por 15s + 800mW/cm2 por 25s (rampa); 200mW/cm2 por 3s + 3 minutos espera + 30s a 600mW/cm2 (pulso); 1600mW/cm2 por 3s (alta intensidade). Após o acabamento e polimento das restaurações, os espécimes foram submetidos à termociclagem (500 ciclos a 5oC e 55oC, 60s em cada banho) e imersos em fucsina básica a 0,5% por 4h. As restaurações foram seccionadas e, após a seleção do corte de maior infiltração, as imagens foram digitalizadas para a avaliação da penetração do corante, em milímetros, através do programa de computação Image Tool. A análise estatística, realizada pela ANOVA a dois critérios e pelo teste de Tukey, não mostrou diferença estatisticamente significativamente entre as técnicas de fotoativação convencional e graduais (rampa e pulso). A técnica de alta intensidade revelou maior infiltração marginal, quando comparada às técnicas convencional, rampa e pulso. Não foi observada diferença significante entre as duas bases de cimento de ionômero de vidro utilizadas, porém, na sua ausência, observaram-se índices significativamente maiores de infiltração. Concluiu-se que as técnicas de fotoativação gradual (rampa e pulso) não foram capazes de minimizar a infiltração marginal, quando comparadas à técnica convencional. A utilização de uma base de cimento de ionômero de vidro sob a resina composta minimiza a infiltração marginal, enquanto que o emprego da técnica de fotoativação com alta intensidade de luz proporciona uma maior infiltração, não contribuindo para uma adequada integridade marginal em restaurações classe V de resina composta, com margens localizadas em dentina. / The purpose of this in vitro study was to evaluate the influence of different glass ionomer cement liners and curing techniques on the microleakage of resin composite restorations. Class V root cavities were prepared in the buccal surfaces of 120 bovine incisors. The specimens were divided into twelve groups of ten each, according to the liner and to the curing technique employed. Group 1- Single Bond + Z100; group 2- RMGIC (Vitrebond) + Single Bond + Z100; group 3- conventional GIC (Ketac Bond) + Single Bond + Z100, which were light cured by conventional technique; the other groups were restored similar to groups 1, 2 and 3, respectively; although, they were light cured by ramp technique (groups 4, 5, 6); pulse technique (groups 7, 8, 9) and high intensity (10, 11, 12). The thickness of the liner was 0.5mm and the resin composite was inserted in one increment. The four curing techniques were applied with different light intensities as follows: 450mW/cm2/ 40s (conventional), 100 - 800mW/cm2 /15s + 800mW/cm2/ 25s (ramp); 200mW/cm2/ 3s + 3 minutes delay + 600mW/cm2/ 30s (pulse); 1600mW/cm2/ 3s (high intensity). After 7 days, the teeth were thermocycled (500 cycles at 5oC - 55oC with a dwell time of 60 seconds) and immersed in aqueous solution of 0.5% basic fuchsin for 4h. Then, they were sectioned and the dye penetration was measured in millimeters by means of a computer program (Image Tool). Data were analyzed by two-way ANOVA and Tukey test. There were no significant differences among conventional, ramp and pulse techniques. The high intensity technique showed significant dye penetration when compared with others curing techniques. There were no significant differences in marginal leakage between the liners (conventional GIC and resin modified GIC), but the microleakage was significantly higher in the groups restored with no liner. No relationship between filling techniques and light curing methods was observed. It can be concluded that sandwich restorations were efficient in microleakage prevention, while the high intensity curing technique may lead to the highest dye penetration values in dentin cavities restored with resin composites.
17

Confiabilidade dos testes de infiltração apical com azul de metileno, rodamina B e sistema de transporte de fluído em obturações de canais após o uso de curativo de hidróxido de cálcio

Brandão, Christian Giampietro 01 April 2005 (has links)
Objetivou-se avaliar se o curativo de hidróxido de cálcio realmente apresenta influência no selamento de obturações de canais, realizadas com cimento de óxido de zinco e eugenol, utilizando-se o transporte de fluídos e a infiltração de corantes com azul de metileno e rodamina B. Foram utilizadas 70 raízes que tiveram seus canais obturados pela técnica da condensação lateral com cimento de óxido de zinco e eugenol, após o uso ou não do curativo de hidróxido de cálcio. A infiltração marginal apical foi avaliada utilizando-se, primeiramente, o sistema de transporte de fluído e, posteriormente, os mesmos espécimes foram imersos em corante, sendo uma metade em Rodamina B a 0,2% e a outra em azul de metileno a 0,5%. Os resultados obtidos mostraram que tanto com o sistema de transporte de fluído, como com a utilização da Rodamina B, o curativo de hidróxido de cálcio não teve qualquer influência no selamento apical das obturações. Todavia, os resultados foram significantes quando da marcação pelo azul de metileno, demonstrando haver interferência desse curativo, a qual tem sido relatada como que física e que, provavelmente, melhoraria a capacidade de selamento das obturações. A observação desse resultado isoladamente poderia levar a supor da possibilidade dessa ocorrência. Contudo, considerando-se que apenas os resultados utilizando o azul de metileno mostraram diferença estatisticamente significante entre os grupos com e sem uso de curativo, o mais sensato é concluir que o hidróxido de cálcio, muito provavelmente, tenha apresentado interação química com o azul de metileno, o que deve ter promovido sua descoloração (pela ação da alcalinidade do hidróxido de cálcio) e resultando, portanto, em dados não confiáveis. / Filling of the root canal system is the end of a sequence of cleaning, shaping and removing bacteria from root canals, and should seal them as more hermetic as possible. Many filling techniques and materials are continuously being developed, trying to reach a perfect seal of the root canal system. The necessity of testing such techniques and material produces a lot of papers analyzing biological and physical properties of root canal fillings. Apical sealing is the more tested physical property, although there is not standardization for it that could provide unquestionable results. Seventy roots canals were filled by the lateral condensation technique with zinc-oxide eugenol sealer, after the use or not of a intracanal medicament of calcium hydroxide paste. Apical marginal leakage was assessed firstly by a fluid transport system and, then, the roots were divided in two groups, being immersed in Rhodamine B or methylene blue dye solutions. Either the fluid transport system results as the Rhodamine B ones, showed no statistically influence of calcium hydroxide use in the sealing capacity of the root fillings. However, when methylene blue was used as tracer, the results were significant, indicating a direct influence of this root canal dressing in the quality of apical sealing of the fillings. This fact is usually explained as a physical action of calcium hydroxide, what should improve the apical sealing. If this finding would be analyzed solely, we could suppose and believe in it but, considering that only methylene blue test showed this statistically significant finding between dressing and no dressing groups, it\'s reasonable to conclude that a chemical interaction between calcium hydroxide and methylene blue should happen, making this tracer uncolored (through alkalinity action), giving us no trustable results at all.
18

Volume do corante rodamina b a 1% infiltrado na região apical, via forame, quando da obturação dos canais radiculares pelos cimentos ah plus, sealer 26 e N-rickert.

MOTTA, Júlio Cesar Alves e 20 February 2014 (has links)
O presente trabalho teve como objetivo avaliar in vitro o volume do corante penetrado em canais preparados com o sistema rotatório Protaper Universal, irrigados com hipoclorito de sódio a 2,5%, impermeabilizados externamente com cianoacrilato de etila e obturados pela técnica convencional com os cimentos AH Plus, Sealer 26 e N-Rickert e cones de guta percha Protaper. Foram utilizados 45 dentes unirradiculares humanos caninos superiores e inferiores. Os dentes foram divididos aleatoriamente em três grupos de 15 dentes cada um: G1 – cimento AH Plus, G2 – cimento Sealer 26 e G3 – cimento N-Rickert. As coroas dos dentes dos três grupos foram removidas com disco de carborundum num comprimento de 17 mm e os dentes foram pesados em balança de precisão estabelecendo o PI (peso inicial). A seguir os espécimes dos três grupos foram imersos em solução de Rodamina B a 1% por 72 horas em tubos de ependorf identificados e em ambiente a vácuo. Findo o prazo experimental os dentes foram lavados em abundância em água corrente e novamente pesados estabelecendo o PF (peso final). A diferença entre PF e PI determinou o peso do corante infiltrado nos três grupos. Isto posto, o peso de cada dente dos três grupos foram transformados em volume de infiltração apical, através da seguinte fórmula V= P/d, onde P é o peso do volume infiltrado (média) de cada dente e d a densidade do corante Rodamina B a 1% utilizada no experimento. Os resultados mostraram que não houve diferença estatística entre os grupos analisados. / This study aimed to evaluate in vitro the volume of the dye that penetrated into canals prepared with Protaper Universal rotary system, irrigated with 2.5% sodium hypochlorite, waterproofed externally with ethyl cyanoacrylate and filled by conventional technique with AH Plus, Sealer 26 and N-Rickert cements and gutta percha Protaper. Forty five upper and lower single-rooted human canines were used. The teeth were randomly divided into three groups of 15 teeth each: G1 - AH Plus, G2 - Sealer 26 and G3 - N-Rickert Sealer. The tooth crowns of the three groups were removed with carborundum disc at a 17 mm lenght and the teeth were weighed on a precision balance, setting the IW (initial weight). The specimens of the three groups were immersed in a 1% Rhodamine B solution for 72 hours in labeld ependorf tubes and vacuum environment. After the experimental period, the teeth were rinsed abundantly in tap water and weighed again, thus setting the FW (final weight). The difference between IW and FW determined the weight of the infiltrated dye in the three groups. That said, the weight of each tooth of the three groups were converted into volume of apical leakage through the following formula V = W/d, where W is the weight of the infiltrated volume (mean) of each tooth and d is the density of 1% Rhodamine B dye used in the experiment. The results showed no statistical difference between the groups analyzed.
19

Avaliação da Infiltração Marginal em Cavidades de Classe II Restauradas com Resina Composta Associada a Outros Materiais de Inserção Direta.

Mondelli, Adriano Lia 20 December 1999 (has links)
As resinas compostas vêm sofrendo inúmeras alterações, com o objetivo de tornar o seu uso adequado para restaurações de dentes posteriores, entretanto, problemas clínicos associados à sua utilização são comumente observados, dentre eles, a microinfiltração marginal. Algumas alternativas clínicas têm sido sugeridas, na tentativa de reduzir as falhas decorrentes do emprego deste material, principalmente em restaurações estendidas à região de cemento, local este onde os problemas se agravaram. O objetivo deste trabalho consistiu, portanto, em estudar a efetividade do vedamento marginal de diferentes materiais aplicados no terço cervical com término em cemento para, em associação à resina composta, restaurar esteticamente cavidades de classe II, através da técnica mista, avaliando-se com esta finalidade o índice de infiltração marginal na interface cemento/material restaurador. Cavidades M.O.D. com margens cervicais estendidas além da junção amelocementária foram confeccionadas em 60 pré-molares humanos livres de cáries, os quais foram distribuídos em grupos de 10 elementos cada, correspondendo a 5 condições experimentais: Grupo controle – em todos os dentes, Scotchbond MP / Z-100; Grupo 1 - Scotchbond MP (Concise) / Concise / Scotchbond MP / Z-100; Grupo 2 – Alpha Bond / Natural Flow / Scotchbond MP / Z-100; Grupo 3 – One step / Aeliteflo / Scotchbond MP / Z-100; Grupo 4 – Prime & Bond 2.1 / Dyract-AP / Scotchbond MP / Z-100; Grupo 5 – Verniz copalite / Velvalloy / Scotchbond MP / Z-100; No sentido de evitar penetração da solução corante em áreas indesejadas. Em todos os dentes os forames apicais foram obstruídos com Scotchbond MP / Z-100. Após 48 horas, as restaurações foram polidas com discos Sof-Lex de granulação fina e submetidas posteriormente a um teste de ciclagem por carregamento oclusal correspondendo a 200 ciclos de 1 a 17kg. Imediatamente após a ciclagem, os espécimes foram armazenados 24 horas em água destilada a 370C. Após este período tiveram a superfície totalmente coberta por uma camada de esmalte de unha, exceto 1mm aquém e além da interface cemento/ material restaurador. Depois foram termociclados em azul de metileno a 2% correspondendo a 180 ciclos de 45 segundos cada, nas temperaturas de 50C, 370C e 550C . Os corpos de prova foram armazenadas em azul de metileno a 2% por mais 24 horas a 370C. Decorrido este período os dentes foram incluídos em bases acrílicas apropriadas para serem adaptadas à máquina de corte, obtendo-se cerca de 3 cortes para cada espécime. Para avaliar o índice de penetração da solução corante nas interfaces cemento/material restaurador, optou-se pela análise qualitativa, através da atribuição de escores previamente determinados. Os resultados obtidos foram então organizados e submetidos aos cálculos estatísticos, concluíndo-se que: • amálgama Velvalloy e a resina composta Z-100 usada como controle apresentaram respectivamente os índices mais severos de infiltração marginal, na interface cemento/material restaurador; • Houve diferença estatística significante entre o Dyract-AP e os demais materiais testados o qual reduziu consideravelmente o índice de infiltração marginal nas interfaces das restaurações; • A resina quimicamente ativada Concise e as fluídas Aeliteflo e Natural Flow ocuparam uma posição intermediária com relação à infiltração marginal, com desempenho estatisticamente igual entre si e desfavoravelmente em relação ao Dyract AP; por outro lado, sobressaíram-se positivamente em comparação ao amálgama; • Não obstante o melhor comportamento apresentado pela resina composta modificada por poliácidos Dyract-AP, observou-se que nenhum material restaurador utilizado foi apto em impedir 100% a penetração da solução corante nas margens cervicais em cemento. / Marginal leakage is one of the clinical problems associated with posterior composite resin. Some clinics alternatives has been suggest, in attempt for reduce the defective of this material, specific in cementum cavities extended, where this problems could be increased. The aim of this study was to evaluated the marginal sealing effectiveness of different materials applied at the cervical third of class II cavities in association with composite resin (sandwich technique). Microleakage at the cement/material interface was measured. M.O.D. cavities with cervical margin extended below the cement-enamel-junction was made at 60 human non carie premolars, that was distributed in groups of 10 elements, ending up at 5 groups as follow: Control group – at each tooth, Scotchbond MP / Z-100; Group 1 – Scotchbond MP (Concise) / Concise / Scotchbond MP Z-100; Group 2 – Alpha Bond / Natural Flow / Scotchbond MP Z-100 Group 3 – One step / Aeliteflo / Scotchbond MP Z-100; Group 4 - Prime & Bond 2.1 / Dyract-AP / Scotchbond MP Z-100; Group 5 – Verniz copalite / Velvalloy / Scotchbond MP Z-100; Before the teeth were prepared and restored with the various materials, the apex were sealed with Scotchbond MP Z-100. After 48 hours the restorations were polished with Sof-Lex and were submitted to the mechanical cycling for 200 cycles of alternated loads, from 1 up to 17 kg. Than the teeth were stored in distilled water at 37ºC for 24 hours. After this the teeth were termocycled in a 2% methylene blue solution, corresponding to 180 cycles of 45 seconds each, at the temperatures of 5ºC, 37ºC, 55ºC. The specimens were stored again in methylene blue solution for 24 hours at 37 ºC. After this period, the teeth were embedded in acrylic bases and sectioned for the evaluation of the infiltration. Microleakage was determined by a qualitative analysis as showed the following conclusions: • The Velvalloy amalgam and the composite resin Z-100 used as the control group showed, respectively, the worst rates of the marginal leakage at the cement/restorative material margin; • There is statically significant between Dyract – AP and the others tested materials that showed lower rates of marginal microleakage; • Concise, Aeliteflo and Natural Flow resins has a medium position in the microleakage ranking, with the same statically performance, and, unfavorable when compared to Dyract-AP; although, it was better than the amalgam; • Although the Dyract-AP has the better performance, none of the testing materials avoid 100% microleakage at cervical margins in cementum.
20

Avaliação da vulnerabilidade natural à contaminação do solo e aqüífero do reservatório Batatã - São Luís (MA) /

Pereira, Ediléa Dutra. January 2006 (has links)
Orientador: José Eduardo Zaine / Banca: Antonio Roberto Saad / Banca: Edson Gomes de Oliveira / Banca: José Luiz Albuquerque Filho / Banca: Fábio Augusto Vieira Reis / Resumo: O mapeamento geológico-geotécnico em áreas urbanas foi utilizado na análise das características do meio físico e processos geológicos, avaliando suas limitações e potencialidades como subsídio à gestão e ao planejamento municipal. A Bacia do Rio Bacanga, localizada na Ilha do Maranhão, no município de São Luis-Maranhão (Brasil), apresenta uma área de 106 km2 que através dos tempos vem passando por um dinâmico processo de ocupação de forma não planejadas, provocando diversos impactos ambientais como assoreamento dos mangues, desmatamentos, aterramentos, impermeabilizações do solo, erosão, contaminação da água, inundações e outros. Os recursos hídricos genuinamente luduvicense são estratégicos para a Ilha oceânica, como reservas que precisam ser preservadas por se tratar de um ecossistema frágil. O estudo foi realizado através do método do detalhamento progressivo (análise do geral para o particular) para determinação e avaliação de áreas vulneráveis a contaminação do solo e da água no Reservatório Batatã. Na etapa geral do método foi elaborado o mapa geológico-geotécnico na escala 1:20.000 onde foram individualizada 6 unidades no terreno. Na etapa de semi-detalhe a pesquisa se direcionou para o estudo da vulnerabilidade natural à contaminação do solo e aqüífero do Reservatório Batatã e entorno. Nesta etapa, os estudos enfocaram uma área de 6,6 km2, para a qual foram geradas cartas na escala de 1:10.000: de declividade, de profundidade do nível de água subterrânea, de superfície potenciométrica do aqüífero livre Barreiras, de material inconsolidado e de uso e ocupação do solo. Nesta etapa, utilizou-se o método de avaliação da vulnerabilidade natural GOD utilizando-se as informações das cartas de unidades de material inconsolidado e da profundidade do nível de água subterrânea sendo gerado o mapa de vulnerabilidade... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The geological-geotechnical mapping in urban areas was used in the analysis of the environment characteristics and geological processes, evaluating its limitations and potentialities as subsidy to the municipal management and planning. The Basin of the river Bacanga is located in the Maranhão lsland, in the city of São Luis - Maranhão (northeast of Brazil) and presents an area of 106 km2. lt has been passing through a dynamic process of non-planned human occupation which has caused many impacts as mangroves landfill environmental in region, deforestation, ground waterproofing, erosion, water contamination, flooding and others. Local water resources constitute a fragile ecosystem but a strategic one for such an oceanic island. Therefore, it must be preserved. The study was done through the method of the gradual detailing (it analyzes first the general aspects and afterwards the specific ones) for determination in the Batatã Reservoir. On Lhe first and most general step, a 1:20.000 scale geologic-geotechnical map was made, on where six land units were set up. The semi-detailed step studied the natural vulnerability to ground and aquifer contaminaton of the Batatã Reservoir and its surroundings. Such stage focused a 6.6 km2 area for which 1:10.000 scale charts were generated: declivity, underground water level depth, potentiometric surface, unconsolidated material and ground occupation. At this phase, the GOD natural vulnerability evaluation approach was used, and then information from the land unit charts of unconsolidated material and underground water level depth was utilized, resulting a map of natural vulnerability concerned to the contamination of ground and aquifer. The map of ground occupation was overlapped on the natural vulnerability map, resulting a map of natural vulnerability and potential contamination of the ground and aquifer of the Batatã Reservoir... (Complete abstract, click electronic address below) / Doutor

Page generated in 0.0759 seconds