• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • Tagged with
  • 7
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Élaboration d’un système in vitro de suivi en continu par spectroscopie d’impédance électrique de l’infection d’une lignée de cellules cancéreuses par un protozoaire parasite : Cryptosporidium parvum / Conception of an in vitro system to continuously monitor by electrical impedance spectroscopy the infection of cancerous cell lines by a protozoan parasite : Cryptosporidium parvum

Dibao-Dina, Alfred 16 January 2015 (has links)
Le Cryptosporidium est la principale cause d’épidémies d’origine hydrique provoquées par des protozoaires parasites dans le monde. Dans cette thèse, nous montrons qu’il est possible d’utiliser la spectroscopie d’impédance électrique pour obtenir in vitro des informations sur le cycle de vie du Cryptosporidium infectant des cultures cellulaires et pour quantifier l’infectivité d’un inoculum. Des cellules HCT-8 (adénocarcinome humain) ont été cultivées dans des puits contenant un réseau d’électrodes interdigitées planaires jusqu’à confluence pendant 76 heures, puis infectées par le Cryptosporidium parvum pendant 60 heures. La réponse impédimétrique a été mesurée entre 100Hz et 1MHz avec une période d’échantillonnage de 7min. Au cours de l’infection, le signal d’impédance présente une série de pics distincts et reproductibles à 12, 23 et 31h post infection (PI) et de minima à 9, 19 et 28h PI. Une modélisation électrique par circuit équivalent révèle que ces variations peuvent être en partie expliquées par l’effet des interactions hôte-parasite sur les zones intercellulaires. En outre, nos données présentent pour la première fois un suivi en temps réel du développement précoce et homogène du parasite, où les phases de prédominance de formes invasives (i.e. zoïtes) et prolifératives (i.e. mérontes) s’alternent et sont respectivement observées aux pics et minima du signal impédimétrique. Finalement, en quantifiant l’amplitude de la réponse en impédance, nous montrons que ce dispositif peut également être utilisé comme un capteur d’infectivité, dont la réponse dès 12h PI s’avère au moins 4 fois plus rapide que d’autres techniques à l’état de l’art. / Cryptosporidium is the main origin of worldwide waterborne epidemic outbreaks caused by protozoan parasites. In this thesis, we show that an in vitro electrical impedance-based device is able to get insights on Cryptosporidium life cycle on a cell culture and to quantify sample infectivity. HCT-8 cells (human adenocarcinoma) were grown to confluency on interdigitated microelectrode arrays during 76 hours and then infected by Cryptosporidium parvum during 60 hours. The impedimetric response was measured at frequencies ranging from 100Hz to 1MHz and a 7min sampling period. As the infection progresses, the impedance signal shows a reproducible distinct succession of peaks at 12, 23 and 31h post infection (PI), and minima at 9, 19 and 28h PI. An electrical equivalent circuit modeling-based approach indicates that these features can be partly explained by the effects of host-parasite interactions on intercellular areas. Furthermore, our data present for the first time a real-time monitoring of early homogeneous parasitic stage development with alternating invasive (i.e. zoites) and proliferative (i.e. meronts) form predominances, observed respectively at peaks and minima in the impedimetric signal. Finally, by quantifying the magnitude of the impedimetric response, we demonstrate this device can also be used as an infectivity sensor as early as 12h PI, thus being at least 4 times faster than other state of the art techniques.
2

Oxydes sans plomb pour la détection de gaz : OSPÉGAZ / Lead-free oxides for gas detection : OSPÉGAZ

El Romh, Mohamad Ali 01 July 2016 (has links)
La détection de gaz, qui utilise aujourd'hui principalement des capteurs optiques, des capteurs électrochimiques à base de plomb et des capteurs catalytiques est un marché très porteur (estimé à 3 milliards d'euros) et doté d'une forte croissance (10% par an). La nécessité de développer de nouveaux systèmes d'instrumentation dédiés à la surveillance de la qualité de l'air intérieur et à la détection de substances dangereuses implique l'étude et le développement de nouveaux capteurs élaborés à partir de produits compatibles avec les enjeux environnementaux (RoHs, REACH), et économiques (matériaux à faible coût, techniques de réalisation fiables, durée de vie élevée). Le projet ANR OSPÉGAZ (Oxydes sans plomb pour la détection de gaz) vise à développer des systèmes d'instrumentations intégrés innovants dédiés à la caractérisation des différentes expositions environnementales en lien notamment avec les actions recommandées dans le cadre du PNSE2 pour les impacts sanitaires avérés. Le travail de thèse présenté dans ce manuscrit fait partie du projet OSPÉGAZ. L'objectif du travail a été, d'une part, de mettre au point un nouveau procédé d'élaboration d'encre au sein du laboratoire UDSMM pour l'élaboration et la caractérisation de films épais poreux, et d'autre part, de réaliser des capteurs de gaz à base de ces films. Nous avons choisi d'utiliser le matériau BaTiO₃, bien connu de la littérature, comme matériau de départ afin de mettre au point le procédé d'élaboration de couches épaisses. Par la suite, nous avons choisi le BaSrTiFeO₃ comme matériau sensible au gaz, et nous avons étudié deux compositions correspondant à deux taux de fer : Ba₀.₈₅Sr₀.₁₅Ti₀.₉Fe₀.₁O₃ (BSTF 10%) et Ba₀.₈₅Sr₀.₁₅Ti₀.₉₈Fe₀.₀₂O₃ (BSTF 2%). Ces matériaux ont été caractérisés dans une large gamme de fréquence (100 Hz à 1 MHz) et de température (25°C à 500°C). Les propriétés diélectriques en fonction de la fréquence et de la température ont été étudiées sur deux structures différentes d'électrodes : capacité parallèle (MIM) et capacité interdigitée (CID). Enfin, des démonstrateurs de capteurs de gas basés sur le principe des capteurs semi-conducteurs, ont été réalisés à partir de films épais poreux (BT, BST, BSFT 10% et 2%). Ces démonstrateurs ont été testés dans les locaux de la société SIMTRONICS sous différents gaz comme le monoxyde de carbone CO (200ppm), le sulfure d'hydrogène H₂S (50ppm) et le dioxyde de soufre SO₂ (20ppm) à 400°C et 450°C. Sous H₂S (50ppm), ils ont montré une plus grande sensibilité relative du BSTF (10%) (55.4%) par rapport au BSTF (2%) (48%) à 450°C. La bonne sensibilité relative et la réponse dynamique très intéressante montrent que le matériau BSTF dispose d'un potentiel très intéressant pour la détection de gaz. L'optimisation de la géométrie des capteurs, du taux de fer et de la température de fonctionnement devrait nous permettre d'améliorer les performances de nos démonstrateurs. / Today gas detection, which now mainly uses optical sensors, electrochemical sensors based on lead, and catalytic sensors, is a very promising market (estimated at 3 billion euros) with a strong growth (10% per year). The need for new instrumentation systems dedicated to the monitoring of the air quality and to the detection of hazardous substances, requires the study and development of new sensors compatible with the European environmental standards : Restriction of the use of Hazardous Substances (RoHS) ; Registration, Evaluation and Authorization of Chemicals (REACh). The OSPÉGAZ project aims to develop innovative integrated instrumentations systems for the characterization of different environmental exposures linked to the actions recommended by the PNSE2 for proven health impacts. Our research project aims to develop innovating and cost-effective gas sensors containing lead-free oxides and dedicated to the detection of flammable gases and protection against toxic risks. The works of the thesis presented in this manuscript is a part of this project. The objectives were, firstly, to develop a new process for ink preparation in UDSMM laboratory, for the elaboration, electrical and physicochemical characterizations, of thick porous film, and secondly to make gas sensors based on these films. We chose to use the BaTiO3 (well-known material in literature) material as a first material in order to develop the process of thick film elaboration. After that, we chose the BaSrTiFeO₃ as gas-sensitive material, and we studied two compositions of Ba₁₋ ₓ Sr ₓ Ti₁₋yFeyO₃ with two different concentrations or iron : Ba₀.₈₅Sr₀.₁₅Ti₀.₉Fe₀.₁O₃ (BSTF 10%) and Ba₀.₈₅Sr₀.₁₅Ti₀.₉₈Fe₀.₀₂O₃ (BSTF 2%). Electrical characterizations were made in a wide range of frequency (100 HZ to 1 MHz) and temperature (25° C to 500° C). The dielectric properties as a function of temperature and frequency were studied using two different structures of capacitance : metal-insulator-metal (MIM) and interdigital electrodes (CID). Finally we have developed semi-conductor gas sensors based on BT, BST and BSTF (10% ; 2%) thick films. All our sensors were tested under different gases such as carbon monoxide CO (200ppm), hydrogen sulphide H₂S (50ppm) and sulfur dioxide SO₂ (20ppm), at various temperature, in the laboratory of SIMTRONICS SAS. We have measured the greatest relative sensitivity under H₂S (50ppm) gas ; 55.4% and 48% respectively for BSTF (10%) and BSTF (2%), at 450°C. Good relative sensitivity and very interesting dynamic responsesof BSTF show that the material has a great potential for the detection of gas. The optimization of the sensor geometry, iron rate and operating temperature should allow us to improve the performance of our demonstrators.
3

Dynamique térahertz des nanotubes de carbone / Terahertz dynamics of carbon nanotubes

Baillergeau, Matthieu 10 December 2015 (has links)
Le développement de circuits mesoscopiques avec une architecture hybride cette dernière décennie a permis d’étudier l’interaction lumière matière dans son aspect fondamental avec des photons dans le régime micro-ondes. Ces développements permettent aujourd’hui d’étudier cette interaction dans le domaine terahertz, gamme spectrale s’étendant de 0.1 THz à 10 THz (0.4 meV-41,3 meV). L’apparition de sources performantes et de méthodes de spectroscopie efficaces telles que la spectroscopie dans le domaine temporel sont des outils utilisables pour l’étude de l’interaction lumière matière dans ce domaine spectral. Dans ce travail de thèse, nous avons développé un outil afin d’étudier cette interaction dans son aspect le plus fondamental composé d’un nanotube de carbone en régime de boîte quantique et d’une cavité térahertz. Le nanotube de carbone est un élément d’autant plus adapté que sa structure électronique est régie par des énergies dont la fréquence équivalente se situe dans le terahertz. La cavité térahertz est un "split ring resonator". Le travail s’est décomposé en deux aspects, avec dans un premier temps le développement d’un banc de spectroscopie térahertz large bande (0.3 THz-20 THz) dans le domaine temporel pour l’étude des résonateurs. En utilisant un procédé original de contrôle du front d’onde d’émission de l’antenne, nous démontrons que le champ térahertz est focalisé en limite de diffraction ce qui ouvre la possibilité d’étudier des résonateurs uniques. Dans un second temps, des mesures de transport électronique ont été effectuées afin de mettre en évidence un couplage entre le résonateur et la boîte quantique. Un couplage avec un mode bosonique est observé. La conductance de ces états est modulée par la source de photons utilisée dans cette étude. Cependant, l’énergie du mode est inférieure à celle observée par les mesures de spectroscopie ne permettant pas de conclure de manière définitive sur l’origine de ce mode. / In the last ten years, research has been devoted to the development of hybrid architecture mesoscopic circuit to study the ligh-matter interaction in the microwaves range. These improvements allow us to study this interaction in the terahertz range extending from 0.1 THz to 10 THz (0.4 meV - 41.3 meV). Moreover, new efficient sources and new spectroscopy schemes like time domain spectroscopy set-up are some tools that can be used to study the light-matter interaction in this range. In this work, we developed a paradigm to study the interaction in the fundamental aspect composed of a carbon nanotube in a quantum dot regime embedded in a terahertz cavity. Carbon nanotube quantum dot is well adapted because of its electronic levels which are separated by energy in the terahertz range. The cavity used for the study is a "split ring resonator". This thesis is decomposed in two parts. Firstly, we built an ultrabroadband terahertz time domain spectroscopy set-up (0.3 THz -20 THz) to study the terahertz resonators. We demonstrated that the terahertz field is focused at the diffraction limit by exciting the antenna with an original scheme based on a control wavefront. Then, electronic transport measurements have been done to highlight the coupling between the cavity and the quantum dot. A coupling with a bosonic mode is observed. The conductance of these states is modified by the source that we used in this work. However, the energy of the observed mode is lower than the fundamental energy mode of the cavity that do not allow us to conclude about the origin of this mode.
4

Dispositif microfluidique pour la quantification de sous-populations de cellules / Microfluidic device for quantification of subpopulations of cells

Manczak, Rémi 27 January 2016 (has links)
La détection quantitative de cellule est généralement réalisée par cytométrie en flux en raison de sa haute sensibilité, cependant cette technique est difficile à mettre en oeuvre pour des analyses de routine ou des analyses au chevet du patient. Les méthodes électrochimiques et en particulier la spectroscopie d'impédance électrochimique ont gagné en popularité en raison de la possibilité de réaliser des analyses sans marquage et de miniaturiser les systèmes d'analyse pour une intégration sur puce. De plus, les avancées récentes dans le domaine des technologies de microfabrication ont permis de développer des électrodes micrométriques ayant de nombreux avantages tels que des hautes impédances dues à des courants très faibles ainsi que la possibilité de les intégrer dans des systèmes microfluidiques. L'objectif de ce travail de thèse se concentre sur la réalisation et l'optimisation de dispositifs microfluidiques contenant les systèmes d'électrodes pour le piégeage immunologique et le comptage impédimétrique de monocytes pro-inflammatoires, marqueurs d'une infection. Compte tenu de l'influence du taux de recouvrement de la surface sur la sensibilité, plusieurs géométries d'électrodes ont été testées. Les meilleures sensibilités et reproductibilités ont été obtenues dans le cas de microélectrodes interdigitées ayant de faibles espaces inter-électrodes (50 µm). D'autre part les études ont également permis de montrer dans ce cas, que la gamme de concentration cellulaire pour laquelle la sensibilité était maximale dépendait de la surface de l'électrode. Les électrodes de plus petites surfaces ont permis d'atteindre une limite de détection inférieure à 10 cellules/mL. De plus, compte tenu de la grande sensibilité des dispositifs ainsi réalisés, ces systèmes ont également été testés pour la caractérisation d'interaction récepteurs-ligands à partir de cellules entières. Ces études ont permis de mettre en évidence l'interaction de cellules CHO exprimant le récepteur A2a à des ligands c-di-AMP pour de très faibles concentrations cellulaires. / The quantitative detection of specific cells is usually carried out by flow cytometry due to its high sensitivity and reliability, however, this technique is not suited for routine screening and point-of-care diagnostics. Electrochemical methods, as electrochemical impedance spectroscopy have gained interest mainly due to a label-free detection and their miniaturization capability required for integration on chip. Furthermore, recent advances in microfabrication based technologies have allowed to develop micron-sized electrodes whose main advantages over conventional electrodes are higher impedances due to smaller currents and the possibility of being integrated inside microfluidic channels. The aim of the present work was the realization and the optimization of microfluidic devices with improved sensitivity targeting the immuno-trapping and counting of pro-inflammatory monocytes as infection markers. Taking into account the influence of the surface coverage on the sensitivity, different geometries were tested. The best sensitivities and reproducibility were recorded in the case of interdigitated micro-electrodes with weak inter-electrodes gap (50 µm). Moreover, experiments carried out with different surfaces demonstrated that there was a threshold beyond which a surface is exploitable for a given slice of concentration. Such microfluidic devices allowed to reach a detection limit around 10 cells/mL. Furthermore, due to the high sensitivity recorded, the devices were also tested to detect ligand binding by cell receptors. These studies have allowed to demonstrate the interaction of CHO-A2a with c-di-AMP for low cell concentrations.
5

Contribution à la mesure de bioimpédance électrique de cellules biologiques par micro-capteurs interdigités : optimisation, conception et validation de capteurs / Contribution to the measurement of electrical bioimpedance of biological cells by interdigitated micro-sensors : Optimization, design and validation of sensors

Ngo, Thanh Tuan 09 July 2015 (has links)
Cette thèse porte sur la conception et la réalisation de micros capteurs à électrodes interdigitées pour la caractérisation des milieux biologiques dans la gamme de fréquences : 100 kHz - 10 MHz. L'objectif principal de ce travail est l’optimisation géométrique de la structure d’un capteur à électrodes interdigitées afin d’élargir la plage fréquentielle de mesure en réduisant les effets de polarisation. Le premier chapitre synthétise les données fondamentales relatives au comportement électrique des tissus biologiques ainsi que leurs propriétés électriques notamment en basses fréquences. Le deuxième chapitre concerne une approche théorique pour l’optimisation du capteur pour élargir la bande de fréquence utile de mesure ; ce chapitre recommande également une nouvelle méthode pour déterminer les paramètres de la double couche à la surface en contact entre les électrodes et le milieu biologique. Dans le troisième chapitre nous proposons une modélisation tridimensionnelle du système d’électrodes chargé par un modèle du milieu biologique sous le logiciel ConventorWare®. Les résultats de simulation sont discutés. Les résultats obtenus nous permettent d’évaluer l'influence des paramètres géométriques de la structure interdigitée du capteur ainsi que les propriétés diélectriques du milieu sur l’impédance bioélectrique. Les facteurs d’influence en fonction de la fréquence sont ainsi maîtrisés lors de la conception d’u capteur interdigité destiné à la mesure de bioimpédance. Dans le quatrième chapitre, les dispositifs ainsi que la conception et la fabrication des composants développés au cours de cette thèse sont décrits. Dans le dernier chapitre, les mesures expérimentales effectuées avec de très faibles volumes de différentes solutions (solutions étalons, sang humain) par cinq micros capteurs à électrodes interdigitées. Les mesures sur les échantillons ainsi que la validation des théories d’optimisation ont été élaborées et discutées. Enfin nous avons comparé nos résultats à des valeurs publiées dans la littérature et nous avons justifié expérimentalement la théorie d’optimisation développée. / This thesis focuses on the design and realization of interdigitated sensors for the electrical characterization of the biological medium within the frequency range: 100 kHz - 10 MHz. The main objective of this thesis is to optimize the geometry of the sensor structure according to the specificities of the interdigitated electrodes structure. This optimization leads to widen the measurement frequency range by reducing the effects of polarization at low frequency. The first chapter synthesizes the basics and fundamentals relative to the electric behavior of biological tissues as well as to their electric properties. The second chapter concerns a theoretical approach for the optimization of the sensor to widen the useful frequency band of measurement; this chapter also presents a new method to determine the parameters of the double layer at the contact interface between the electrodes and the biological medium. A three-dimensional modelling of the system, the electrodes being loaded with a biological medium, is implemented using ConventorWare® software and the results discussed in the third chapter. The results obtained allow us to evaluate the influence of the geometrical parameters of the interdigitated structure of the sensor as well as the dielectric properties of the medium on the bioelectric impedance. In the fourth chapter, the devices developed during this thesis are described. The design and the manufacturing of components are presented. The last chapter deals with the experimental measurements obtained with very small volumes of the different solutions (standard solutions, human blood) using five micro sensors that we built in the laboratory. The measurements as well as the validation of the theoretical approach are discussed. Finally we have compared our results with published values in the literature and validated our experimental and theoretical approaches developed in this work.
6

Interdigitated ITO sensor for ECIS monitoring of breast cancer cells / Capteur interdigité en ITO pour le suivi par mesures d'impédance de cellules cancèreuses du sein

Martinez Santamaria, Jaime Andres 05 February 2019 (has links)
Dans la lutte contre le cancer, la médecine personnalisée est une stratégie nécessaire et très prometteuse. En effet, il est primordial de pouvoir tester l'innocuité et l'efficacité de médicaments anticancéreux sur des échantillons provenant du patient lui-même, du fait de la diversité des réponses entre patients. Le but est d'améliorer la performance des soins et d'éviter des traitements inutiles et même parfois nocifs pour le patient. Ainsi, l'exemple de la chimiothérapie illustre parfaitement cette stratégie. Le cout élevé des molécules thérapeutiques, la nocivité de ces molécules et les réponses variées des patients face à une même molécule implique le recours aux tests de ces molécules sur un échantillon provenant du patient lui-même. Il en résulte un intérêt croissant dans le développement de tests simples, robustes et peu couteux permettant l'évaluation de la chimio sensibilité de cellules biologiques issues d'une biopsie. Les problématiques liées à la mise en place de tels tests sont la quantité de cellules disponibles dans une biopsie, la diversité des molécules thérapeutiques à tester et également le choix d'une technique de détection permettant de suivre la cinétique d'action des molécules sur les cellules biologiques. L'une des réponses à la faible quantité de cellules est le développement de tests dans des environnements microfluidiques qui nécessitent donc l'intégration et la miniaturisation d'une technique de détection. La stratégie qui sera étudiée dans cette thèse est l'utilisation de l'impedancemetrie par le biais d'électrodes inter digitées d'Oxyde d'Etain et d'Indium (ITO) pour l'analyse quantitative de l'état de cellules de cancer du sein pour des applications de criblage de médicaments anticancéreux. Ce matériau présente l'avantage d'être transparent permettant ainsi des mesures d'impédance qui pourrait être couplées à des mesures optiques dans un environnement microfluidique. Dans une première partie, nous avons caractérisé et étudié des électrodes inter digitées d'or et d'ITO pour des mesures d'impédance avec des cellules cancéreuses. Cette caractérisation par spectroscopie d'impédance réalisée dans des solutions de milieu de culture en présence et absence de cellules, ont permis de démontrer que la différence de sensibilité entre ces deux matériaux provenait à la fois d'une différence de comportement résistif mais également d'une différence d'impédance interfaciale, dans les deux cas à la défaveur de l'ITO. Après ce constat, nous avons donc poursuivi l'étude afin d'évaluer les capacités de l'ITO pour des mesures de chimio sensibilité de la molécule 5-fluorouracil et également proposé une stratégie pour améliorer la sensibilité de l'ITO tout en conservant sa transparence. La stratégie développée consiste en la modification de la surface de d'électrodes d'ITO avec de l'oxyde d'iridium pour améliorer la sensibilité de l'ITO, tout en gardant sa transparence. Cette approche est intéressante pour pouvoir concevoir un dispositif transparent et facile à coupler avec un système d'observation microscopique dans un environnement microfluidique / In the fight against cancer, personalized medicine is a necessary and very promising strategy. In fact, it is essential to be able to test the safety and effectiveness of anticancer drugs on samples from the patient, due to the diversity of responses between patients. The aim is to improve the performance of health care and avoid unnecessary and sometimes harmful treatments. Thus, chemotherapy perfectly illustrates this strategy. The high cost of therapeutic molecules, the harmfulness of these molecules and the varied responses of patients involve the use of tests with chemotherapeutic molecules on samples coming from cancer patients. This results in a growing interest in the development of simple, robust and inexpensive tests for assessing the chemo sensitivity of biological cells from a biopsy. The problems related to carrying out such tests are the quantity of cells available in a biopsy, the diversity of the therapeutic molecules to be tested and also the choice of a detection technique, able to monitor the kinetics of action of the molecules on the biological cells. One solution to the small amount of cells is to carry out the tests in microfluidic environments which therefore require the integration and miniaturization of a detection technique. The strategy that will be studied in this thesis is the use of electrical impedance with interdigitated electrodes of indium tin oxide (ITO) for the quantitative analysis of the state of breast cancer cells for screening applications of anticancer drugs. This material has the advantage of being transparent allowing impedance measurements that could be coupled to optical measurements in a microfluidic environment. In the first part, we characterized and studied interdigitated electrodes of gold and ITO for impedance measurements with cancer cells. This impedance spectroscopy characterization carried out in culture medium solutions, in the presence and absence of cells, demonstrated that the difference in sensitivity between these two materials comes from a difference in resistive behavior and also from a difference in interfacial impedance, in both cases to the disadvantage of ITO. After this, we continued the study to evaluate the capabilities of ITO for chemosensitivity measurements using the molecule 5 fluorouracil and we suggested a strategy to improve the sensitivity of ITO while maintaining its transparency. The strategy developed consists of modifying the surface of ITO electrodes with iridium oxide to improve the sensitivity of the ITO, while keeping its transparency. This approach is interesting for developing a transparent device and easy to couple with a microscopic observation system in a microfluidic environment
7

Intégration d’une méthode d’actuation électrocinétique sur biocapteur plasmonique / Integrating an electrokinetic actuation method on a plasmonic biosensor

Avenas, Quentin 20 December 2018 (has links)
Cette thèse porte sur le développement d’un capteur plasmonique intégrant une fonction d’actuation des objets visés. L’objectif est de passer outre la limite de diffusion rencontrée à basse concentration en piégeant les particules sur la surface de détection. La stratégie adoptée est de structurer le film d’or servant à la détection de manière à pouvoir l’utiliser pour mettre en mouvement le fluide et les molécules par le biais de champs électriques. Le transfert de masse est réalisé par diélectrophorèse et électroosmose, deux effets électrocinétiques mis en oeuvre par des électrodes servant à la fois d’actuateur et de capteur plasmonique. Un état de l’art exhaustif et des simulations multiphysiques ont permis de concevoir un prototype de capteur intégré constitué d’électrodes interdigitées en or permettant la détection plasmonique. Le dispositif proposé a été obtenu par microfabrication en salle blanche puis caractérisé avant l’étude de ses performances. Une première phase de tests sur un système modèle, des billes de polystyrène dans de l’eau, a permis d’apporter la preuve de concept du fonctionnement du capteur, qui est effectivement capable de piéger rapidement les objets visés à sa surface afin de les détecter. Les mécanismes de transfert de masse ont été expliqués et la preuve de l’amélioration de la limite de détection par un facteur supérieur à 100 a été apportée. Dans un second temps, les performances du capteur appliqué à des objets biologiques ont été évaluées. Celui-ci piège efficacement des levures et des protéines, mais aucune amélioration n’a été observée dans le cas de la détection spécifique de l’hybridation entre deux brins d’acide désoxyribonucléique (ADN). Les causes de ce résultat ont été discutées et comprises et deux solutions différentes ont été explorées : l’adaptation de la fréquence d’opération et l’optimisation de la géométrie des électrodes. Ainsi, cette étude a permis de souligner la problématique de la mise en oeuvre d’effets électrocinétiques dans des milieux biologiques et de réfléchir aux pistes pertinentes pour sa résolution. / This thesis focuses on the development of an integrated plasmonic sensor capable to perform mass transport on targeted objects. The goal is to overcome the diffusion limit by trapping particules directly on the sensing surface. The adopted strategy was to structure the gold layer used for plasmonic detection in order to use the sofabricated structures to set the fluid and the molecules in motion by applying electric fields in the fluid. The mass transfer is realized through dielectrophoresis and electroosmosis, those two electrokinetic effects being operated by electrodes acting as sensor and actuator at the same time. An exhaustive state of the art as well as multiphysical simulations allowed us for designing a prototype for an integrated sensor consisting in gold interdigitated electrodes enabling plasmoninc sensing. The proposed device was obtained through microfabrication in clean room facilities and was characterized before the study of its performances. A first sequence of tests on a model system – polystyrene microbeads in water – brought the proof of concept we needed to validate the correct operation of the sensor, which is indeed capable of quickly trapping targeted objects on its surface and detecting them. The mass transfer mechanisms were explained and we showed the enhancement of the limit of detection by a factor greater than 100. In a second phase, performances of the sensor applied to biological objects were evaluated. It can effectively trap yeasts and proteins but no enhancement has been observed while detecting DNA hybridization events. Causes for this result were discussed and understood and two different solutions were explored: the adaptation of the operating frequency and the optimization of the electrodes geometry. Thus, this study highlighted the problematic of operating electrokinetic effects in biological media and suggested relevant leads towards its resolution.

Page generated in 0.0895 seconds