• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 9
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da infiltração microbiana na interface implante-abutment em conexões tipo hexágono interno e cone-morse de implantes osseointegráveis / Evaluation of bacterial leakage at implant abutment interfaces of implants wiht internal hexagonal

SANTANA, Washington Macedo de 28 September 2007 (has links)
Made available in DSpace on 2014-07-29T15:21:59Z (GMT). No. of bitstreams: 1 Dissertacao Washington M de Santana.pdf: 773538 bytes, checksum: 8a934007fd255f4536cfdfdbde213eb7 (MD5) Previous issue date: 2007-09-28 / The scientific literature has reported that dental implants can be affected by the oral microorganisms through the formation of a bacterial biofilm. The region most affected is the connection between the implant platform and the prosthetic abutment, particularly in implants with an external connection. Therefore, the region of the implant/abutment connection can participate in the development of peri-mucositis or peri-implantitis. They propose that these implant/abutment connections known as morse taper provide an effective seal against microorganisms. Thus the objective of this research was to evaluate the microleakage on the implant/abutment interface of internal hex and morse taper prosthetic connections. Thirty five (35) implants were selected and divided into seven (7) groups (5 groups of implants from Brazilian manufacturers and 2 groups of implants manufactured abroad). The tested implants were Straumann (Straumann AG® / Switzerland), Ankylos (Dentsply-Friadent® / Germany), AR Morse (Conexão/Sistema de Prótese® São Paulo-SP), Titamax CM (Neodent® /Curitiba-PR), Titamax II Plus (Neodent®/Curitiba-PR), Stronger (Sin/Sistema Nacional de Implante® São Paulo - SP) e Titanium Fix CM (AS Technology / São José dos Campos-SP). For the microbiological test the bacterium Enterococus faecalis (ATCC 29212) was selected. This bacterium was inoculated in the interior aspect of the implant followed by immediate installation and final torque (N/cm) of the prosthetic abutment. The implant/abutment set up was then placed in a Brain Heart Infusion broth (BHI) and incubated in this broth for 14 days. During this period, the cloudiness of the broth was evaluated at days 7 and 14. The data were statistically analyzed by the Kruskal Wallis method. The results demonstrated that all samples from both Ankylos and Neodent CM groups did not present microleakage. Although 20% of samples from Conexao AR Morse group presented microleakage, there was no significant statistical difference when compared to the former two groups. Furthermore, all samples from Straumann,Titanium Fix CM, Neodent Titamax II Plus, and SIN Strong groups presented microleakage after 14 days of culture (p=0.05), though correlation analysis among these samples did not reveal significant statistical differences. / A literatura tem ressaltado que os implantes osseointegráveis podem ser afetados por transtornos decorrentes da formação de biofilme bacteriano em sua superfície. A região acometida envolve principalmente a conexão entre a plataforma do implante e o abutment, situação evidenciada especialmente nos implantes de conexões externas. Assim, tal situação pode culminar na formação de mucosites ou até mesmo perimplantites. Alguns tipos de conexões têm sido colocados no mercado pelos fabricantes de implantes com proposta de melhor selamento microbiológico. Baseada nesta consideração, esta pesquisa teve como propósito avaliar a microinfiltração na interface implante-abutment das conexões protéticas de alguns sistemas de hexágono interno e das conexões internas conemorse, que propõem capacidade efetiva de vedamento microbiológico. Para sua execução foram selecionados 35 implantes divididos em 7 grupos (5 grupos de implantes de procedência de empresas nacionais e 2 grupos advindos de empresas importadas). Os implantes analizados foram Straumann (Straumann AG® / Switzerland) e Ankylos (Dentsply-Friadent® / Germany), AR Morse (Conexão/Sistema de Prótese® São Paulo-SP), Titamax CM (Neodent® /Curitiba-PR), Titamax II Plus (Neodent®/Curitiba-PR), Stronger (Sin/Sistema Nacional de Implante® São Paulo - SP) e Titanium Fix CM (AS Technology / São José dos Campos-SP). Para os testes de contaminação, foi selecionada a bactéria Enterococcus faecalis (ATCC 29212), sendo esta inoculada no interior do implante com a imediata instalação e torque (N/cm) do respectivo abutment (pilar protético). Posteriormente, o conjunto pilar/implante inoculado foi colocado em meio de cultura caldo infusão de cérebro e coração (BHI) e mantido neste meio por um período de 14 dias. Durante este período, o controle da contaminação indicando microinfiltração foi feito pelo turvamento do meio de cultura, avaliado aos 7 dias e aos 14 dias após inoculação. Após a coleta dos dados, foi aplicado teste estatístico pelo método não paramétrico de Kruskal- Wallis e os resultados demonstraram que todas as amostras do grupo Ankylos e Neodent CM não apresentaram microinfiltração, sendo que 20% do grupo Conexão AR Morse apresentaram microinfiltração, contudo sem apresentar diferenças estatísticas significativas quando comparados com os grupos anteriores. Ainda, as amostras dos grupos Straumann, Titanium-Fix CM, Neodent Titamax II Plus e SIN Strong apresentaram todas as amostras infiltradas após 14 dias do estudo (nível de significância alfa=0,05) e na avaliação da correlação entre estas amostras, constatou-se que não houve diferenças estatísticas significativas entre si.
12

Reabilitação protética na região auricular: análise por elementos finitos de implantes maxilofaciais extraorais conexão hexágono externo e cone Morse, investigação da fotoestabilidade e caracterização espectroscópica de um elastômero maxilofacial tipo-A / Prosthetic rehabilitation in the auricular region: finite elements analysis of extraoral maxillofacial implants, photostability investigation and spectroscopy characterisation of modified maxillofacial elastomers type-A

Pimentel, Marina Leite 12 April 2017 (has links)
O grande desafio da Implantodontia é alcançar resultados a longo prazo com maior preservação dos tecidos ósseos, resposta adequada dos tecidos conjuntivos e manutenção da estabilidade secundária adequada para a retenção de próteses. Estes fatores evitam a perda indesejável tanto do tratamento reabilitador quanto dos tecidos ósseos de suporte. A região extraoral apresenta menores espessuras ósseas em comparação às regiões de maxila e mandíbula, especialmente no osso temporal. Portanto, os seguintes aspectos foram investigados: (i) Análise pelo Método dos Elementos Finitos (FEA) de 16 modelos virtuais, com aplicação de forças estáticas de tensão e compressão nos pontos médios entre os implantes. Três implantes maxilofaciais extraorais foram posicionados no osso temporal, onde um deles foi posicionado sobre o processo mastóide. Este estudo foi totalmente realizado em ambiente computacional. Foram empregados dois tipos de conexões protéticas e intermediários retos de conicidades 20º e 45º, posicionados virtualmente no modelo de osso temporal, com paralelismo entre eles. Foi desenhada uma barra virtual para retenção protética do tipo barra-clipe da prótese auricular. Foram consideradas as melhores configurações aquelas apresentando distribuição uniforme e branda das tensões de von Mises sobre o tecido ósseo adjacente aos implantes. (ii) Confecção de corpos de prova com graus variáveis de pigmentação para (a) melhorar a reprodutibilidade da coloração (b) entender e reduzir o processo de descoloração para melhorar a longevidade das próteses. Um elastômero maxilofacial tipo A foi pigmentado intrinsecamente de acordo com os seis tons da Escala de Fitzpatrick. Uma técnica de pigmentação foi desenvolvida a partir dos resultados obtidos a partir de uma Escala de Fitzpatrick impressa em papel e dos pigmentos intrínsecos de cores primárias. Este dimetil-metilvinil-siloxano reforçado por platina A 223-30 (Factor II, Inc., Lakeside, AZ, USA) apresenta dureza \"Shore-A\" 30. As amostras foram expostas a fotoenvelhecimento acelerado, e sua degradação mapeada com Espectroscopia UV/Vis/NIR. Concluiu-se que: (i) Os implantes com conexão cone Morse plataforma 3.7 tem melhor comportamento biomecânico com intermediários de 45o e altura de 2mm. Sugere-se planejamento cirúrgico visando a instalação a 3 horas para o temporal esquerdo e 9 horas para o temporal direito, mais 6 horas (mastóide). Implantes com conexão cone Morse plataforma 4.0 apresentaram comportamento biomecânico desejável com intermediários de 20o e alturas de 2mm or 4mm. Para implantes com conexão cone Morse plataforma 4.0, sugere-se a instalação a 6-9-12 horas para o temporal direito, e 12-6-3 para o esquerdo, visando comportamento biomecânico adequado. Sugere-se que os implantes extraorais Brånemark hexágono externo com plataforma 4.1 regular ou expandida sejam preferencialmente empregados com intermediários de 20o. (ii) O SiO2 5% pode ser adicionado à preparação do silicone para retardar o desbotamento da prótese maxilofacial. O TiO2 traz mudanças visuais significativas e pode ser considerado como opacificador. / Major challenges in Implantology include: achieving longevity of implants, bone tissue preservation, connective tissue suitable answer and maintenance of secondary stability in order to retain prosthesis. These factors avoid the undesirable loss of both rehabilitation treatment and supporting bone tissues. The extraoral region has less bone depth compared to the maxilla and mandible regions, especially for the temporal bone. Therefore, the following aspects were investigated: (i) Finite Elements Analysis (FEA) of 16 virtual models, with static application of tension and compression forces in medium points between implants. Three extraoral maxillofacial implants were placed on the temporal bone, which one of them was placed on the mastoid process. This study was made entirely in a computational environment. Two prosthetic connection types and straight Intermediários were employed, with conicities of 20º and 45º, placed virtually on the temporal bone model, mutually parallel. A virtual bar for bar-clip prosthetic retention of auricular prosthesis was designed. The best configurations were considered to be the ones presenting uniform and mild von Mises tension distribution over the bone tissue around the implants. (ii) Generation of samples with varying degree of pigmentation to (a) improve the reproducibility of the colouration (b) understand and minimise the discolouration process to improve prosthetics longevity. A maxillofacial elastomer type A was intrinsically pigmented according to the six tones of the Fitzpatrick Scale. A pigmentation technique was developed from spectroscopy outcomes of paper printed Fitzpatrick Scale and the primary colors pigments. This platinum reinforced dimethyl methylvinyl siloxane A 223-30 (Factor II, Inc., Lakeside, AZ, USA) presents \"Shore-A\" hardness 30. The samples were exposed to accelerated photo aging, and their degradation mapped with UV/Vis/NIR Spectroscopy. The effects of exclusion of oxygen and inclusion of nanoparticle fillers during prosthetic formulation were investigated. It was concluded that: (i) Morse taper prosthetic connection 3.7 platform implants, should be employed with 45o abutments with 2mm height. The surgical planning shall be for placement 3 hours for the left temporal bone and 9 hours for the right, and in 6 hours (mastoid). Morse taper prosthetic connection 4.0 platform implants behaved biomechanically desirably with 20o abutments in 2mm or 4mm heights. For the Morse taper connection 4.0 platform implants, their placement shall be in 6-9-12 hours, for the right temporal, and 12-3-6, for the left temporal, in order to achieve proper biomechanical behaviour. The Brånemark extraoral external hexagon implant, with 4.1 platform (normal or expanded) should preferrably be used with 20o abutments. (ii) The SiO2 5% may be added to the silicone preparation in order to slow maxillofacial prosthesis colour fading. The TiO2 brings visually significant changes and may be considered as an opacifier.
13

Reabilitação protética na região auricular: análise por elementos finitos de implantes maxilofaciais extraorais conexão hexágono externo e cone Morse, investigação da fotoestabilidade e caracterização espectroscópica de um elastômero maxilofacial tipo-A / Prosthetic rehabilitation in the auricular region: finite elements analysis of extraoral maxillofacial implants, photostability investigation and spectroscopy characterisation of modified maxillofacial elastomers type-A

Marina Leite Pimentel 12 April 2017 (has links)
O grande desafio da Implantodontia é alcançar resultados a longo prazo com maior preservação dos tecidos ósseos, resposta adequada dos tecidos conjuntivos e manutenção da estabilidade secundária adequada para a retenção de próteses. Estes fatores evitam a perda indesejável tanto do tratamento reabilitador quanto dos tecidos ósseos de suporte. A região extraoral apresenta menores espessuras ósseas em comparação às regiões de maxila e mandíbula, especialmente no osso temporal. Portanto, os seguintes aspectos foram investigados: (i) Análise pelo Método dos Elementos Finitos (FEA) de 16 modelos virtuais, com aplicação de forças estáticas de tensão e compressão nos pontos médios entre os implantes. Três implantes maxilofaciais extraorais foram posicionados no osso temporal, onde um deles foi posicionado sobre o processo mastóide. Este estudo foi totalmente realizado em ambiente computacional. Foram empregados dois tipos de conexões protéticas e intermediários retos de conicidades 20º e 45º, posicionados virtualmente no modelo de osso temporal, com paralelismo entre eles. Foi desenhada uma barra virtual para retenção protética do tipo barra-clipe da prótese auricular. Foram consideradas as melhores configurações aquelas apresentando distribuição uniforme e branda das tensões de von Mises sobre o tecido ósseo adjacente aos implantes. (ii) Confecção de corpos de prova com graus variáveis de pigmentação para (a) melhorar a reprodutibilidade da coloração (b) entender e reduzir o processo de descoloração para melhorar a longevidade das próteses. Um elastômero maxilofacial tipo A foi pigmentado intrinsecamente de acordo com os seis tons da Escala de Fitzpatrick. Uma técnica de pigmentação foi desenvolvida a partir dos resultados obtidos a partir de uma Escala de Fitzpatrick impressa em papel e dos pigmentos intrínsecos de cores primárias. Este dimetil-metilvinil-siloxano reforçado por platina A 223-30 (Factor II, Inc., Lakeside, AZ, USA) apresenta dureza \"Shore-A\" 30. As amostras foram expostas a fotoenvelhecimento acelerado, e sua degradação mapeada com Espectroscopia UV/Vis/NIR. Concluiu-se que: (i) Os implantes com conexão cone Morse plataforma 3.7 tem melhor comportamento biomecânico com intermediários de 45o e altura de 2mm. Sugere-se planejamento cirúrgico visando a instalação a 3 horas para o temporal esquerdo e 9 horas para o temporal direito, mais 6 horas (mastóide). Implantes com conexão cone Morse plataforma 4.0 apresentaram comportamento biomecânico desejável com intermediários de 20o e alturas de 2mm or 4mm. Para implantes com conexão cone Morse plataforma 4.0, sugere-se a instalação a 6-9-12 horas para o temporal direito, e 12-6-3 para o esquerdo, visando comportamento biomecânico adequado. Sugere-se que os implantes extraorais Brånemark hexágono externo com plataforma 4.1 regular ou expandida sejam preferencialmente empregados com intermediários de 20o. (ii) O SiO2 5% pode ser adicionado à preparação do silicone para retardar o desbotamento da prótese maxilofacial. O TiO2 traz mudanças visuais significativas e pode ser considerado como opacificador. / Major challenges in Implantology include: achieving longevity of implants, bone tissue preservation, connective tissue suitable answer and maintenance of secondary stability in order to retain prosthesis. These factors avoid the undesirable loss of both rehabilitation treatment and supporting bone tissues. The extraoral region has less bone depth compared to the maxilla and mandible regions, especially for the temporal bone. Therefore, the following aspects were investigated: (i) Finite Elements Analysis (FEA) of 16 virtual models, with static application of tension and compression forces in medium points between implants. Three extraoral maxillofacial implants were placed on the temporal bone, which one of them was placed on the mastoid process. This study was made entirely in a computational environment. Two prosthetic connection types and straight Intermediários were employed, with conicities of 20º and 45º, placed virtually on the temporal bone model, mutually parallel. A virtual bar for bar-clip prosthetic retention of auricular prosthesis was designed. The best configurations were considered to be the ones presenting uniform and mild von Mises tension distribution over the bone tissue around the implants. (ii) Generation of samples with varying degree of pigmentation to (a) improve the reproducibility of the colouration (b) understand and minimise the discolouration process to improve prosthetics longevity. A maxillofacial elastomer type A was intrinsically pigmented according to the six tones of the Fitzpatrick Scale. A pigmentation technique was developed from spectroscopy outcomes of paper printed Fitzpatrick Scale and the primary colors pigments. This platinum reinforced dimethyl methylvinyl siloxane A 223-30 (Factor II, Inc., Lakeside, AZ, USA) presents \"Shore-A\" hardness 30. The samples were exposed to accelerated photo aging, and their degradation mapped with UV/Vis/NIR Spectroscopy. The effects of exclusion of oxygen and inclusion of nanoparticle fillers during prosthetic formulation were investigated. It was concluded that: (i) Morse taper prosthetic connection 3.7 platform implants, should be employed with 45o abutments with 2mm height. The surgical planning shall be for placement 3 hours for the left temporal bone and 9 hours for the right, and in 6 hours (mastoid). Morse taper prosthetic connection 4.0 platform implants behaved biomechanically desirably with 20o abutments in 2mm or 4mm heights. For the Morse taper connection 4.0 platform implants, their placement shall be in 6-9-12 hours, for the right temporal, and 12-3-6, for the left temporal, in order to achieve proper biomechanical behaviour. The Brånemark extraoral external hexagon implant, with 4.1 platform (normal or expanded) should preferrably be used with 20o abutments. (ii) The SiO2 5% may be added to the silicone preparation in order to slow maxillofacial prosthesis colour fading. The TiO2 brings visually significant changes and may be considered as an opacifier.

Page generated in 0.0707 seconds